1 Optical Design Manufacturing, Inc. Sprint 2.5 Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures Technical Support Document

2 2 Table of Contents I. Introduction... 3 II. Test Site Overview... 4 III. Equipment... 5 IV. Fiber Optic Endface Inspection and Cleaning... 7 V. db Loss Testing VI. Closeout Documentation VII. Technical Support and FAQ... 24

3 3 I. Introduction This document will serve as a guide to perform the testing procedures for the fiber optic portion of the Sprint Alcatel-Lucent (ALU) 2.5 GHz cellular tower build. Technicians will utilize equipment from Optical Design Manufacturing to inspect, clean, and save images of fiber endfaces, as well as test for light loss on the optical cables. This user guide contains the following sections: Test Site Overview describes the layout of the optical fibers in the cellular tower installation. Equipment provides detailed information on the TTK 650 Test kit and how to use it for the Sprint ALU 2.5 GHz installation. Fiber Optic Endface Inspection and Cleaning outlines the steps taken to ensure endface quality prior to testing installed systems. db Loss Testing describes how to test the db loss of the trunk cable and the full system. Closeout Documentation explains how to save and report images and loss values. Technical Support and FAQ provides contact information for ODM technical support and answers several frequently asked questions.

4 4 II. Test Site Overview Tower fiber optic installations will contain: One (1) Base Unit One (1) Riser Cable, containing 12 fibers per sector - 6 LC pairs at bottom, MPO at top Three (3) Sector Cables consisting of twelve (12) fibers each - MPO at bottom, 6 LC pairs at top Three (3) Remote Radio Units (RRU s) Tower installations require a certified climber to perform the test procedures associated with the top of the tower. The illustration below shows the typical installation to be tested. Remote Radio Unit (RRU) Primary Sector Cable (3 pairs per sector) Spare Fiber Cylinder Spare Sector Cable (3 pairs per sector) MPO Connection (Riser to Sector) Riser Cable (12 fibers per sector) Fiber Distribution Panel BTS

5 5 III. Equipment This section provides details on the equipment required to perform the following tasks associated with the Sprint ALU 2.5 installation: System db loss Portable video inspection of all optical fiber connectors Complete endface cleaning of all connector interfaces Closeout documentation TTK 650 Test Kit

6 6 TTK 650 Test Kit - Bill of Materials MODEL DESCRIPTION APPLICATION QTY. DLS 355 Dual Laser Source 1310nm/1550nm SC Conn. Single mode fiber light source for db loss testing 1 RP 460 VIS 400 Power Meter w/ Zero db/set Ref, 1000 data point store & USB download to OpTest Software Video Inspection Scope w/usb and InSpec Software, LC, SC, 1.25mm and 2.5mm adapter tips included Power meter used with light source for db loss measurement and storage, and USB transfer to PC for closeout documentation Portable connector inspection device to view connector endfaces and ensure connectors meet IEC standard after proper cleaning TAB 008 Dell Tablet (or equivalent)with Case and Charger Allows for touch-based fiber endface inspection with the VIS 400 HDP probe and inspec application AC 029 LC Adapter for RP460 Optical Power Meter Allows LC connection to optical power meter 1 AC 300 CR2 Battery Kit / 5 per pack Spare Battery Kit 1 AC 523 LC-clipped LC-SC, SM, 9/125 Fiber, 1 Meter Cable Fiber patch cord to allow calibration of test instruments for complete system db loss test AC 4500 SM Loopback with Lanyard Allows for calibration of equipment and test of loopback installations VF nm Red Laser Allows user to observe bends and breaks in optical fiber 1 AC 602 LC-LC Adapter LC adapter to allow access to LC duplex connector on Optical Jumper Cable AC 805 Micro USB Cable Stream live images of fiber endfaces from VIS 400 to Dell Tablet for endface inspection and closeout documentation CK 092 SqR Pad with Fiber Wash Pen Wet/Dry cleaning system for connector endfaces 1 AC 089 One Click Connector Cleaner For LC connector ends and bulkheads for quick dry clean only AC 015 Pelican Style Hard Carry Case Large protective carrying case for all instruments and accessories AC 807 Accessory Kit for TTK Sprint ALU 2.5 MODEL DESCRIPTION APPLICATION QTY. DLS 350 Dual LED Source 850nm/1300nm SC Conn Multimode light source for db loss testing 1 AC 4600 MM Loopback with Lanyard Allows for calibration of equipment and test of loopback installations AC 533 LC-clipped LC-SC, MM, 50/125 Fiber, 1 Meter Cable Fiber patch cord to allow calibration of test instruments for complete system db loss test AC 176 MPO Inspection Tip Allows inspection of MPO-style connectors 1 AC 083 MPO One-Click Cleaner For MPO connector ends and bulkheads, quick dry clean AC 830 Accessory Kit - Sprint ALU 2.5 MODEL DESCRIPTION APPLICATION QTY. AC 830 Male/Female MPO 12 Fiber - Pigtailed LC Pairs MM Patch Cables Multimode patch cables to allow calibration of test equipment and pre-test of riser/sector cables 1

7 7 IV. Fiber Optic Endface Inspection and Cleaning Contamination of fiber connector surfaces is the top reason for link failure in the installation of optical fiber cable. It is imperative for installers and technicians to follow the guidelines in this section in order to ensure the quality of the connector endface prior to testing installed systems. The following inspection and cleaning procedures should be used before installing or testing any fiber optic jumper or trunk cable. Only use approved test sets, inspection equipment, and cleaning supplies. Any moveable debris on a fiber optic connector endface is not allowed. After three dry cleaning attempts to remove debris, a wet/dry cleaning process is recommended. Pass or Fail ratings on fibers are determined according to the IEC document Ed 1.0. Cleaning The inspec software offers automated pass/fail of fiber endfaces when receiving images from the VIS 400 inspection scope. Inspect fiber endfaces to determine viability; always clean until all moveable debris is clear and endface is as clean as possible. Before Cleaning After Cleaning Auto-analyzed images from VIS 400 using inspec software

8 8 Dry Cleaning LC MPO One-click cleaner - Push fiber ends into the adapter on the one-click cleaner until the unit clicks. For fibers inside bulkheads, remove plastic cap from one-click cleaner and insert into the bulkhead opposite the fiber. Push until unit clicks. Cletop cleaner - Using the lever on the side of the unit, retract the sliding door to reveal the lint-free wipe. Press the fiber endface into the top of the wipe and drag downward with moderate pressure. Wet/Dry Cleaning SqR pad and fiber wash pen - Isolate a lint-free wipe using the attached card, then apply a coin-sized spot of cleaning solution to the top of the wipe using the fiber wash pen. Press the fiber endface into the wet spot on the wipe, then drag the fiber downward to the dry portion of the wipe, applying moderate pressure. NOTE: To verify the most recent test, inspection, and closeout documentation requirements, or if cleaning does not produce acceptable results, contact your construction manager or follow the appropriate Sprint 2.5 escalation procedure.

9 9 Inspection Installations will require the inspection and grading of all fiber ends in the riser and sector cables to comply with IEC Technicians will archive all riser and sector fiber ends as a pre-test. Saving images is vital to the correct documentation of services rendered for the customer; saved images will be included in closeout documentation. 1. To connect the VIS 400 to the tablet, plug the micro USB adapter cable into the tablet s micro USB port, then plug the VIS 400 into the USB 2.0 port on the adapter cable. To connect the VIS 400 to a PC, simply plug the VIS 400 into a USB 2.0 port on the computer. 2. Open the inspec software and navigate to the Test Settings tab at the top of the window. Set the Analysis Mode to Automatic, the Fiber Type to Multi Mode, and the IEC Profile to Multi Mode PC, as shown below. The VIS 400 will show up in the Video Source drop-down menu under ODM HDP Probe or USB 2.0 Camera. 3. To save site location and other data along with images, navigate to the Report Settings tab in inspec and fill out all of the fields in the window. This information will be available in VIS reports. 4. Navigate to the Main tab in the inspec window.

10 10 5. The 1.25mm inspection tip for the VIS 400 will be used to inspect individual fibers in LC pairs, as shown below. The LC pairs will be located: -At both ends of the cables running from BTS to Fiber Distribution Panel -At the bottom-end of the riser cable -At the radio-end of the primary and spare sector cables 6. Use the focus wheel on the VIS 400 probe to obtain a focused image in the inspec window. The blue bar below the image window indicates the current focus level. A higher focus will give a clearer image. Focus Method

11 11 7. Touch or click the Analyze button to the left of the image to begin the auto pass/fail analysis. 8. When the analysis has finished, inspec will display a still image of the fiber endface with a green PASS or red FAIL marker in the top left corner. If the fiber end does not pass automatic analysis, clean the fiber, re-focus the image, and try again. 9. If the image receives a PASS, touch or click the button that reads Capture Image, just under the analyze button. A Save As dialogue box will pop up. At this point, you can create a new folder in which to save the images. It is a good idea to name the folder with the location information to help differentiate between sites. 10. Name fiber endface images using ODM s image naming convention, shown below.

12 The MPO/MTP inspection tip for the VIS 400 will be used to inspect individual fibers in the 12-fiber MPO connectors, as shown below. The MPO connectors will be located: -At the top-end of the riser cables -At the riser-end of the sector cables 12. The MPO connectors must be inspected using the manual inspection method in the inspec software. To begin, navigate to the Test Settings tab at the top of the inspec window. Set the Analysis Mode to Manual, the Fiber Type to Multi Mode, and the IEC Profile to Multi Mode PC, as shown below. 13. Use ODM s proprietary External Focus Method to focus the fiber endface image on the inspec screen. Focusing using this method is accomplished by rotating the body of the probe while holding the MPO connector in place within the inspection tip. See the red arrow in the picture below.

13 An example of a focused MPO connection is shown above. The procedures outlined in Steps 15 through 17 must be completed for every three core/cladding areas seen on the MPO endface (4 times per connector). To scroll along the line of fibers on the MPO endface, use the lever on the MPO/MTP inspection tip, as shown below. 15. Obtain a clear, focused image of three fiber endfaces on the MPO connector. 16. Ensure that all three core/cladding areas are acceptable according to the criteria outlined in IEC See table below.

14 If all three fiber endfaces are clean and pass the manual inspection, click the Pass button and then click Capture Image to save the image of the three connectors. 18. Repeat Steps 15 through 17 for the rest of the fiber endfaces on the MPO connector. 19. Name fiber endface images using ODM s image naming convention, shown below. Use numbers to indicate which set of three endfaces are in the image. There will be four sets of endfaces per MPO connector. NOTE: To verify the most recent test, inspection, and closeout documentation requirements, or if cleaning does not produce acceptable results, contact your construction manager or follow the appropriate Sprint 2.5 escalation procedure.

15 15 V. db Loss Testing db loss testing is the process of determining how much light is lost along the length of fibers under test. Technicians must use an approved light source and power meter along with appropriate test jumpers to complete the test. This guide will only describe the procedures for testing one sector. The db loss test procedures outlined below will be performed on the fiber runs for each sector, however. Technicians will perform two separate sweeps for db loss readings: 1. All fibers as a pre-test 2. Full fiber runs as an on-site test Pre-Test - BTS Cables 1. Connect the RP 460, DLS 350, AC 533 orange duplex jumper, and AC 4600 loopback module together using an LC bulkhead adapter as shown above. 2. Turn on both the RP 460 and the DLS 350 and set them to a wavelength of 850nm. 3. Put the RP 460 into dbm mode by pressing the db/dbm key on the unit. The RP 460 should read between -22 and -26 dbm when all fibers are clean and connected correctly. 4. Once the RP 460 is holding a steady reading in dbm mode, hold down the db/dbm key for four seconds. The RP 460 will switch to db mode and read 0.00dB. Do not switch the unit back to dbm mode; all testing will be done in db mode.

16 16 5. Separate the loopback module from the RP 460 and DLS 350, leaving the orange referencing cables attached to the units. The loopback module will be attached the to one end of the BTS pair to be tested, and the RP 460/DLS 350 will be attached to the other end of the same BTS cable using the paired cables. 6. When all jumpers are in the correct position, the loss along the BTS cable will be displayed in db on the RP 460 screen. This number may not exceed 3.0dB. If this number is between 0 and 3.0dB, move on to the next BTS cable. Readings do not need to be saved at this time. If the number is over 3.0 db, clean all connections and try again. Negative readings are not acceptable. 7. Continue to perform the db loss test procedure on each remaining BTS pair. Pre-Test - Riser/Sector Cables 1. Connect the RP 460, DLS 350, AC 533 orange duplex jumper, AC 830 male and female MPO pigtailed cables and AC 4600 loopback module together using LC bulkhead adapters as shown above. The loopback module and paired orange cable must be attached to the same jacket-color pair on either end of the AC 830 accessory cables. 2. Turn on both the RP 460 and the DLS 350 and set them to a wavelength of 850nm. 3. Put the RP 460 into dbm mode by pressing the db/dbm key on the unit. The RP 460 should read between -22 and -26 dbm when all fibers are clean and connected correctly. NOTE: Users should connect to multiple corresponding jacketed pairs in the AC 830 accessory cables in order to find the jacketed pair that gives a dbm reading closest to -20dBm before moving on to step 4. This will ensure the most accurate test results and will help to prevent negative loss readings.

17 17 4. Once the RP 460 is holding a steady reading in dbm mode, hold down the db/dbm key for four seconds. The RP 460 will switch to db mode and read 0.00dB. Do not switch the unit back to dbm mode; all testing will be done in db mode. 5. Remove the pigtailed referencing cable with the male MPO end (if testing the Riser cable) or the referencing cable with the female MPO end (if testing the Sector) from the test setup shown in step Connect the Riser or Sector cable under test in the place of the cable that was removed in step 5. The final test setup will contain the RP 460/DLS 350 connected to the paired orange referencing cable, one of the pigtailed AC 830 cables, either the Riser or Sector cable under test, and the loopback module. 7. When all jumpers are in the correct position, the loss along the pair on the Riser or Sector cable will be displayed in db on the RP 460 screen. This number may not exceed 3.0dB. If this number is between 0 and 3.0dB, move the loopback and RP 460/DLS 350 combination to the next jacketed pair cable. Readings do not need to be saved at this time. If the number is over 3.0 db, clean all connections and try again. Negative readings are not acceptable. On-Site Test - System 1. Connect the RP 460, DLS 350, AC 533 orange duplex jumper, and AC 4600 loopback module together using an LC bulkhead adapter as shown above. 2. Turn on both the RP 460 and the DLS 350 and set them to a wavelength of 850nm.

18 18 3. Put the RP 460 into dbm mode by pressing the db/dbm key on the unit. The RP 460 should read between -22 and -26 dbm when all fibers are clean and connected correctly. 4. Once the RP 460 is holding a steady reading in dbm mode, hold down the db/dbm key for four seconds. The RP 460 will switch to db mode and read 0.00dB. Do not switch the unit back to dbm mode; all testing will be done in db mode. 5. Separate the loopback module from the RP 460 and DLS 350, leaving the orange referencing cables attached to the units. The loopback module will be attached the to the top end of the system pair to be tested, and the RP 460/DLS 350 will be attached to the bottom end of the same system cable using the paired cables. NOTE: The locations where the test jumpers and loopback module will be inserted to test the system loss will be slightly different depending on the status of the pair under test. Primary pairs will be tested at the RRU and the BTS unit, and Spare pairs will be tested at the spare fiber cylinder and Fiber Distribution Panel. See the diagrams on the next page for a visual representation of these differences. 6. When all jumpers are in the correct position, the loss along the sytem pair will be displayed in db on the RP 460 screen. This number may not exceed 6.0dB. If this number is between 0 and 6.0dB, press the Save button on the RP 460 to save the reading, then move on to the next system pair. If the number is over 6.0 db, clean all connections and try again. Negative readings are not acceptable. 7. Continue to perform the db loss test procedure on each remaining system pair. 8. Upload the db loss readings saved to the RP 460 into the OpTest software from ODM. For detailed instructions on completing closeout reports, refer to section VI: Closeout Documentation.

19 19 Spare Pair Test For spare pairs, connect the loopback module to the pair at the spare fiber cylinder. The paired orange jumper cables attached to the RP 460 and DLS 350 will be connected to the corresponding pair in the fiber distribution panel. Primary Pair Test For primary pairs, connect the loopback module to the pair at the RRU. The paired orange jumper cables attached to the RP 460 and DLS 350 will be connected to the corresponding pair at the BTS unit.

20 20 VI. Closeout Documentation One loss test will be reported when installing fiber on the Sprint ALU 2.5 tower build. This test will be performed on the primary and spare fibers in the system as outlined in section V. The db loss readings taken on these fiber pairs can be reported easily using ODM s OpTest software. 1. Connect the RP 460 to a computer using the supplied USB cable. 2. Open the OpTest software and place the software into Dump mode by navigating to Settings>Data Mode>Dump Mode. 3. Click Settings>Report Settings to access the Report Settings box. Check Enable next to the 850 wavelength to set the software to mark each reading as Pass/Fail on the report. Set the maximum db loss at 6.0, as shown below.

21 21 4. In the Report Settings box, select the cable color configuration that corresponds to the loss test that is being reported. When the final report is exported to a spreadsheet, the colors of the cables in the Sprint ALU 2.5 build will populate in the Comments section. Click OK to exit Report Settings. 5. Fill out the Test Site, Customer. and User information on the right side of the OpTest window. All of this information will appear in the final closeout report. 6. Press the USB button on the RP 460. All of the data points saved to the device s internal memory will appear in the window to the left of the Test Site and Customer Information windows. 7. Click File>Export to Excel to create an Excel file with all of the db loss readings, cable codes, and testing information included.

22 22 Sample Closeout Report - Insertion Loss Readings

23 23 Sample Closeout Report - Fiber Endface Images NOTE: There are many fiber endface images that must be recorded in the Sprint ALU 2.5 build. Multiple pages like the one shown above must be submitted to satisfy the closeout documentation requirements.

24 24 VIII. Technical Support and FAQ Frequently Asked Questions Q. What is the difference between dbm and db? A. db (decibel) is a unit used to express values of power level on a logarithmic scale. dbm is an absolute optical power measurement referenced to 1 milliwatt of optical energy. It is the starting measurement of the db loss measurements. Q. Why do I get a negative db reading? A. This reading is often the result of the calibration cables not being as clean and aligned as the cable under measurement. This negative reading is common while measuring short-distance cables (less than 100 feet). Always keep reference patch cables clean and free from contamination. Negative readings greater than -.5dB are indicative of other problems in the measurement. In this case, call our technical support group at (603) Q. Will my reading be saved in the RP 460 memory while the battery is changed? A. Yes the RP 460 will retain measurements in a non-volatile memory. Q. Why do I need to inspect all fiber connections? A. Short-distance fiber systems typically fail as a result of contaminated connector ends. More than 90 percent of all failures are due to endface debris. The use of a Video Inspection Scope ensures quality in a connected fiber system. Technical Support If you need technical assistance or have specific questions about any procedures or guidelines in this guide, please contact our technical support team: During Business Hours 8AM to 5PM Eastern Standard Time Please call us at Evenings/Weekends us at tech.support@odm-inc.com Please include your phone number and we will contact you. On YouTube Visit our YouTube page for helpful videos Visit Our Website

Datasheet: MultiFiber Pro

Datasheet: MultiFiber Pro Datasheet: MultiFiber Pro First MPO tester to support both Singlemode and Multimode MPO fiber testing Data centers are growing, fueled by the proliferation of media, virtualization and the need for more

More information

Datasheet: MultiFiber Pro Update

Datasheet: MultiFiber Pro Update Datasheet: MultiFiber Pro Update Datasheet: MultiFiber Pro Update First MPO tester to support both Singlemode and Multimode MPO fiber testing Data centers are growing, fueled by the proliferation of media,

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Datasheet: MultiFiber Pro Optical Power Meter and Fiber Test Kits Data centers are growing, fueled by the proliferation

More information

Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation

Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation Scope Version 4 January 2018 Firmware 26.0.0.6c1973b or Later REQUIRED! This document describes Common Public Radio Interface (CPRI) testing

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and

More information

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope OLP-87/87P SmartClass Fiber PON Power Meter and Microscope The Viavi Solutions OLP-87 is an FTTx/PON power meter for use in qualifying, activating, and troubleshooting B-PON, E-PON, G-PON, and next-generation,

More information

OPERATIONS GUIDE OWL

OPERATIONS GUIDE OWL t T h Optical Wavelength Laboratories OPERATIONS GUIDE MICRO OWL 2 OPTICAL POWER METER Model Numbers: MO-2 MO-2V Opt ic l a a W v e le n g t h L a b o ra t o r ie s - - n e m ip u q E t s e T OWL r e ib

More information

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing.   Rev. 1/31/17 Page 1 of 12 Fiber Optic Testing Testing is used to evaluate the performance of fiber optic components, cable plants and systems. As the components like fiber, connectors, splices, LED or laser sources, detectors and

More information

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning Loss Budgets TIA (Cabling)

More information

RCIT Cable Certification Testing Revised 10/2017

RCIT Cable Certification Testing Revised 10/2017 RCIT Testing Revised 10/2017 General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall

More information

Datasheet: CertiFiber Pro Optical Loss Test Set

Datasheet: CertiFiber Pro Optical Loss Test Set Datasheet: CertiFiber Pro Optical Loss Test Set The CertiFiber Pro is a Tier 1 (basic) fiber certification solution and part of the Versiv Cabling Certification product family. The Versiv line also includes

More information

ST800K-U Optical Power Meter. User Manual V1.0

ST800K-U Optical Power Meter. User Manual V1.0 User Manual V1.0 Contents 1. Summary... 1 2. Functions... 2 3. Specifications... 2 4. Layout... 4 5. Operation... 5 6. Maintenance... 7 7. Faults & Solutions... 8 8. Appendix A...9 9. Appendix B...11 10.

More information

Versiv makes you money every time you use it.

Versiv makes you money every time you use it. Datasheet: CertiFiber Pro Optical Loss Test Set The CertiFiber Pro is a Tier 1 (basic) fiber certification solution and part of the Versiv Cabling Certification product family. The Versiv line also includes

More information

Datasheet: CertiFiber Pro Optical Loss Test Set

Datasheet: CertiFiber Pro Optical Loss Test Set Datasheet: CertiFiber Pro Optical Loss Test Set The CertiFiber Pro is the Tier 1 (basic) fiber certification solution and part of the Versiv Cabling Certification product family. The Versiv line also includes

More information

Datasheet: SimpliFiber Pro

Datasheet: SimpliFiber Pro Datasheet: SimpliFiber Pro Datasheet: SimpliFiber Pro SimpliFiber Pro makes testing simple Fluke Networks' SimpliFiber Pro Optical Power Meter incorporates new and innovative features to give technicians

More information

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL Revision:1.0 is registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective

More information

OpticalProducts. Illuminating Your Network. Testing the World s Networks

OpticalProducts. Illuminating Your Network. Testing the World s Networks OpticalProducts Illuminating Your Network Testing the World s Networks Fibre Optic Testers Ease of use and cost-effectiveness Trend s Family of Optical Products Has Increased The new products include Optical

More information

Compact live fiber identifier with integrated optical power meter

Compact live fiber identifier with integrated optical power meter FI-Series Live Fiber Identifier Compact live fiber identifier with integrated optical power meter User Manual ZP-PKG-0535 REV 1 Notice Copyright Trademarks Every effort was made to ensure that the information

More information

T-BERD /MTS 5800 Network Tester Fiber Channel Layer 2 Traffic

T-BERD /MTS 5800 Network Tester Fiber Channel Layer 2 Traffic Quick Card T-BERD /MTS 5800 Network Tester Fiber Channel Layer 2 Traffic This quick card outlines how to configure and run a Fiber Channel Layer 2 Traffic Test with a recommended test suite of Throughput,

More information

Datasheet: CertiFiber Pro Optical Loss Test Set

Datasheet: CertiFiber Pro Optical Loss Test Set Datasheet: CertiFiber Pro Optical Loss Test Set Datasheet: CertiFiber Pro Optical Loss Test Set The CertiFiber Pro is a Tier 1 (basic) fiber certification solution and part of the Versiv Cabling Certification

More information

VIP-35 Manual. Video Inspection Probe

VIP-35 Manual. Video Inspection Probe VIP-35 Manual Video Inspection Probe Foreword Thank you for purchasing our products. Before assembly and use, make certain that all of the parts you have ordered are present. Check the packaging carefully

More information

Fiber Meter. Specification & User Manual

Fiber Meter. Specification & User Manual Specification & User Manual 2009 Copyright 2009, reserves the right to modify specifications without prior notice Page 1 of 8 Table of Contents 1. Description and Features.......3 2. Specification......4

More information

FTK200. Users Guide. Optical Fiber Test Kit

FTK200. Users Guide. Optical Fiber Test Kit FTK200 Optical Fiber Test Kit Users Guide April 2000, Rev. 1 4/03 2000, 2003 Fluke Corporation. All rights reserved. Printed in USA. All product names are trademarks of their respective companies. LIMITED

More information

OFI-400 Series Optical Fiber Identifiers. OFI-400 Series Models

OFI-400 Series Optical Fiber Identifiers. OFI-400 Series Models OFI-400 Series Optical Fiber Identifiers Quick Reference Guide MODEL FIBER SIZE DESCRIPTION AND FUNCTION OFI-400 SM fibers: 250 µm coated 900 µm coated Ribbon 2 mm jacketed 3 mm jacketed Designed for use

More information

SimpliFiber Pro. Users Manual. Optical Power Meter and Fiber Test Kits

SimpliFiber Pro. Users Manual. Optical Power Meter and Fiber Test Kits SimpliFiber Pro Optical Power Meter and Fiber Test Kits Users Manual September 2008, Rev. 2 6/12 2008, 2010, 2012 Fluke Corporation. All product names are trademarks of their respective companies. LIMITED

More information

FTE6100 Tunable Laser Source User's Guide

FTE6100 Tunable Laser Source User's Guide FTE6100 Tunable Laser Source User's Guide Revision A 05/2017 Information contained in this manual is believed to be accurate and reliable. However, no responsibility is assumed by Terahertz Technologies

More information

Mortara X-Scribe Tango+ Interface Notes

Mortara X-Scribe Tango+ Interface Notes Mortara X-Scribe Tango+ Interface Notes To setup Tango+ with the X-Scribe stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate

More information

LTX Optical Distribution Panels. Ordering Guide

LTX Optical Distribution Panels. Ordering Guide Contents LTX Optical Distribution Panels... 1... 1 Section One: LTX Overview... 3 1RU and 2RU Panels... 3 4RU Panels... 3 Patch Panels... 3 Combination Panels Patch and Splice... 4 Section Two: Unloaded

More information

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Model 9110 Portable Airborne Particle Counter (particle counter). This guide will help you

More information

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber The Road to Single Mode: Direction for choosing, installing and testing single mode fiber Adrian Young Leviton Network Solutions Jim Davis Fluke Networks Adrian Young, Sr. Applications Engineer Leviton

More information

ISO/IEC testing LC to LC (Duplex Multimode) DTX-MFM

ISO/IEC testing LC to LC (Duplex Multimode) DTX-MFM Page 1 of 5 ISO/IEC 14763-3 testing LC to LC (Duplex Multimode) DTX-MFM ISO/IEC 11801 now refers fibre testing to ISO/IEC 14763-3. More importantly, the limits have changed and we'll show you how in this

More information

OPTICAL POWER METER WITH SMART DETECTOR HEAD

OPTICAL POWER METER WITH SMART DETECTOR HEAD OPTICAL POWER METER WITH SMART DETECTOR HEAD Features Fast response (over 1000 readouts/s) Wavelengths: 440 to 900 nm for visible (VIS) and 800 to 1700 nm for infrared (IR) NIST traceable Built-in attenuator

More information

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver 27.3.2012 1(12) CXX Series User Manual Teleste Corporation CXE810 Fibre optic receiver 27.3.2012 2(12) Contents Introduction... 3 Installation... 3 Housing... 3 Powering... 4 Interfaces... 4 Fibre installation...

More information

OFI Optical Fiber Identifier User s Guide

OFI Optical Fiber Identifier User s Guide OFI Optical Fiber Identifier User s Guide OFI Optical Fiber Identifier User s Guide 2002-2008, AFL Telecommunications, all rights reserved. OFI1-11-1000 Revision A, 05.02.08 Specifications are subject

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Datasheet: SimpliFiber Pro

Datasheet: SimpliFiber Pro Datasheet: SimpliFiber Pro Datasheet: SimpliFiber Pro SimpliFiber Pro makes testing simple Fluke Networks' SimpliFiber Pro Optical Power Meter incorporates new and innovative features to give technicians

More information

Pulse Biomedical QRS-Card Tango M2 Interface Notes

Pulse Biomedical QRS-Card Tango M2 Interface Notes Pulse Biomedical QRS-Card Tango M2 Interface Notes To setup Tango M2 with your stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate

More information

DTX. Users Manual. Fiber Test Kit

DTX. Users Manual. Fiber Test Kit DTX Fiber Test Kit Users Manual PN 2411346 December 2004 2004 Fluke Corporation. All rights reserved. Printed in USA. All product names are trademarks of their respective companies. LIMITED WARRANTY AND

More information

FIBER QUICKMAP. Users Manual. Multimode Troubleshooter

FIBER QUICKMAP. Users Manual. Multimode Troubleshooter FIBER QUICKMAP Multimode Troubleshooter Users Manual January 2011, Rev. 1 7/11 2011 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY

More information

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation Broadband Cable Networks August 30, 2007 1(8) CXX Series User Manual Teleste Corporation CXE800 Fibre Optic Receiver Broadband Cable Networks August 30, 2007 2(8) Introduction The CXE800 is a unidirectional,

More information

OTS-300 Express Series Power Meters/Sources and Testers

OTS-300 Express Series Power Meters/Sources and Testers OTS-300 Express Series includes intelligent, versatile optical meters, sources, and testers that simultaneously test and store dual wavelength attenuation measurements. At the press of a button, dual wavelength

More information

Keyed LC Connector Solution A LANscape Solutions Product

Keyed LC Connector Solution A LANscape Solutions Product Applications Department of Defense installations Secure government facilities Research labs Organizations with a desire to segregate networks due to privacy or security concerns Keyed LC Connector Solution

More information

Instructions for Use: Video Inspection Scope with Display

Instructions for Use: Video Inspection Scope with Display Instructions for Use: Video Inspection Scope with Display Brand Name of Product Video Inspection Scope Generic Name of Product Video Inspection Scope Product Code Number(s) FIS-004 Intended Use For visually

More information

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes To setup Tango M2 with the XScribe cardiac stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables

More information

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes To setup Tango M2 with your CardioSoft (V6.01 or higher), simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables

More information

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Fiber Optic Wall Mount Enclosure 8430 Series 3M Fiber Optic Wall Mount Enclosure 8430 Series Installation Instructions January 2014 3 78-0013-9429-1-A Table of Contents 1.0 Description...3 2.0 Parts...4 3.0 Assembly...4 4.0 Mounting the Enclosure...6

More information

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION PART 1 - GENERAL 1.1 SUMMARY SCOPE SECTION 25170 TESTING, IDENTIFICATION AND ADMINISTRATION 1. This section includes the minimum requirements for the testing, certification administration and identification

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

Lensed Fibers & Tapered Ends Description:

Lensed Fibers & Tapered Ends Description: Lensed Fibers & Tapered Ends Description: LaseOptics Corporation ( LaseOptics ) has been producing next generation optical lensed fibers. LaseOptics Lensed Optical Fibers technology is proprietary integrated

More information

2 GENERAL DESCRIPTION

2 GENERAL DESCRIPTION GENERAL DESCRIPTION 2 1.4 Getting Help Our Customer Service Group is available in North America from 7:30 a.m. to 8:00 p.m. (Eastern Standard Time), Monday to Friday. Electro-Optical Engineering (Corporate

More information

Philips StressVue Tango M2 Interface Notes

Philips StressVue Tango M2 Interface Notes Philips StressVue Tango M2 Interface Notes To setup Tango M2 with the StressVue stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate

More information

CI-218 / CI-303 / CI430

CI-218 / CI-303 / CI430 CI-218 / CI-303 / CI430 Network Camera User Manual English AREC Inc. All Rights Reserved 2017. l www.arec.com All information contained in this document is Proprietary Table of Contents 1. Overview 1.1

More information

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall obtain authorization from

More information

TECHN. Purpose. Background. to prepare the. A A Patch cord. horizontal infrastructure

TECHN. Purpose. Background. to prepare the. A A Patch cord. horizontal infrastructure Understanding the use of the PanMPO in 10GBASE SR and 40GBASE SR4 Channels Purpose The purpose of this document is to describe the usage and reasoning behind the development and characteristics of the

More information

PM-1500 / LS-1500 Fiber Optic Power Meter and Light Source Operating Instructions. Quality Fiber Optic Test Equipment

PM-1500 / LS-1500 Fiber Optic Power Meter and Light Source Operating Instructions. Quality Fiber Optic Test Equipment PM-1500 / LS-1500 Fiber Optic Power Meter and Light Source Operating Instructions Quality Fiber Optic Test Equipment Terahertz Technologies Inc. 169 Clear Rd, Oriskany NY 13424 888-U.S.-OTDRS (876-8377)

More information

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display. Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display. Your Stack ST8961 VS module allows you to synchronize, overlay, and record data available on your Stack

More information

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable). Nuclear Sensors & Process Instrumentation Fiber Cable Basics Fiber-optic communication is a method of transmitting information from one place to another by sending light through an optical fiber. The light

More information

DS2460Q QAM Analysis Meter

DS2460Q QAM Analysis Meter DS2460Q QAM Analysis Meter Key Benefits Comprehensive tool for installation and maintenance of cable networks Fast spectrum analysis, 5~1220 MHz 5~1052MHz (Analog TV), 46~1052MHz (Digital TV) Digital TV

More information

PHORCE (standalone version)

PHORCE (standalone version) PHORCE (standalone version) PRODUCT BRIEF The PHORCE product family is designed to extend the SuperSpeed USB3.0 connections beyond the typical 3 meter reach of copper cables. The standalone version of

More information

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved. RIGOL Quick Guide 2016 RIGOL TECHNOLOGIES, INC. All Rights Reserved. DSA800E DSA800E Series Spectrum Analyzer General Inspection 1. Inspect the shipping container for damage If your shipping container

More information

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module Key features The market s first BPON/EPON/GPON power meter module Selective FTTx power meter

More information

CN Remove the scanner assembly (X476 and X576 models) and all doors/covers.

CN Remove the scanner assembly (X476 and X576 models) and all doors/covers. CN598-67045 www.hp.com/support IMPORTANT: Ensure the product firmware is upgraded to at least version 1336MR before performing this repair procedure. If the firmware upgrade cannot be completed, contact

More information

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes To setup Tango M2 with the Q-Stress cardiac stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232

More information

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved. SLS-50 Stabilized Laser Source User s Manual Shineway Technologies, Inc. All rights reserved. Safety Instructions The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the

More information

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications Model Title CC-Link IE Controller Network Compatible CC-Link IE Controller Network Recommended Network Wiring Parts Specifications Management number: BAP-C0401-028-A CC-Link Partner Association (1/31)

More information

Model OTDV Broadcast Transport Links OPERATING MANUAL

Model OTDV Broadcast Transport Links OPERATING MANUAL Model OTDV-1250 Broadcast Transport Links OPERATING MANUAL 24926 Highway 108 Sierra Village, CA 95346 Phone: (800) 545-1022 Fax: (209 586-1022 Rev. X5 E-Mail: sales@olsontech.com 02/23/10 Table of Contents

More information

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes Welch Allyn CardioPerfect Workstation Tango+ Interface Notes To setup Tango+ with the CardioPerfect stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232

More information

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM g GE Interlogix Fiber Options Instruction Manual S700V & S702V FIBER-OPTIC VIDEO TRANSMISSION SYSTEM Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment

More information

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity HD Flex Patch Panel Part Numbers: FLEX1UPN**, FLEX2UPN**, FLEX4UPN** Panduit Corp. 2018 INSTALLATION INSTRUCTIONS Note: HD Flex Patch Panels are compatible with HD Flex Fiber System Components. HD Flex

More information

JD725A Cable and Antenna Analyzer - Dual Port

JD725A Cable and Antenna Analyzer - Dual Port COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS JD725A Cable and Antenna Analyzer - Dual Port Key Features Portable and lightweight handheld instrument Built-in wireless frequency bands as well as the most

More information

Light Source. Specification & User Manual

Light Source. Specification & User Manual Light Source Specification & User Manual Page 1 of 11 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4

More information

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows:

Start Up or Shut Down Hunting Function. Using the Receiver. If there is a short circuit in the cable, it will display as follows: If there is a short circuit in the cable, it will display as follows: Push key (No) to exit calibration function. Push key (Yes) to repeat measurement process. 11 Note: The calibration will recover the

More information

Automate Pulse Set-Up Instructions

Automate Pulse Set-Up Instructions Automate Pulse Set-Up Instructions ABOUT THE AUTOMATE SHADES SKILL The Automate Pulse app allows for control of your motorized window treatments through your smartphone/tablet THE APP ALLOWS FOR: Individual

More information

Sidelighter TM Optical distance to fault measurement module

Sidelighter TM Optical distance to fault measurement module Sidelighter TM Optical distance to fault measurement module Available only at: Sidelighter TM Introducing the latest in optical fiber measurements and versatility Artisan Laboratories Corporation s hand

More information

OP940. Insertion Loss & Return Loss Meter Instruction Manual. (Also supports the OP725 Integration)

OP940. Insertion Loss & Return Loss Meter Instruction Manual. (Also supports the OP725 Integration) Insertion Loss & Return Loss Meter Instruction Manual (Also supports the OP725 Integration) www.optotest.com 1.805.987.1700 Contacting OptoTest Corporation 1.805.987.1700 (7:30 a.m. to 5 p.m. PST) www.optotest.com

More information

Fiber Optic Meter Fiber Optic Source

Fiber Optic Meter Fiber Optic Source FOM/FOS Fiber Optic Meter Fiber Optic Source Warning To avoid injury: do not service the FOM or FOS unless you are qualified to do so. The service information provided in this document is for the use of

More information

The University of Texas at Austin September 30, 2011

The University of Texas at Austin September 30, 2011 SECTION 27 08 20 COPPER TESTING PART 1 - GENERAL 1.1 SUMMARY A. Test measurements shall be taken for all balanced-twisted pair cabling, including horizontal and backbone copper cables and wall-to-rack

More information

RIGOL. 快速指南 Quick Guide DSA800 系列频谱分析仪. DSA800 Series Spectrum Analyzer RIGOL Technologies, Inc. All Rights Reserved.

RIGOL. 快速指南 Quick Guide DSA800 系列频谱分析仪. DSA800 Series Spectrum Analyzer RIGOL Technologies, Inc. All Rights Reserved. RIGOL 快速指南 Quick Guide 2011 RIGOL Technologies, Inc. All Rights Reserved. DSA800 系列频谱分析仪 DSA800 Series Spectrum Analyzer General Inspection 1. Inspect the shipping container for damage If your shipping

More information

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D) Perle Fast Ethernet Fiber to Fiber Media Converter Module Installation Guide C-100MM-XXXXX CM-100MM-XXXXX Unmanaged Module Managed Module P/N 5500313-10 (Rev D) Overview This document contains instructions

More information

Excel recommends Fluke Networks, this section is written around the use of this range of test equipment.

Excel recommends Fluke Networks, this section is written around the use of this range of test equipment. Testing Excel recommends Fluke Networks, this section is written around the use of this range of test equipment. Twisted Pair Copper This section describes and sets out the requirements for Class D (Cat

More information

More Skills 14 Watch TV in Windows Media Center

More Skills 14 Watch TV in Windows Media Center M05_TOWN5764_01_SE_SM5.QXD 11/24/10 1:08 PM Page 1 Chapter 5 Windows 7 More Skills 14 Watch TV in Windows Media Center You can watch and record broadcast TV in Windows Media Center. To watch and record

More information

OP750. Multichannel Source Instruction Manual

OP750. Multichannel Source Instruction Manual Multichannel Source Instruction Manual www.optotest.com 1.805.987.1700 Contacting OptoTest Corporation 1.805.987.1700 ( 7:30 a.m. to 5 p.m. PST) www.optotest.com engineering@optotest.com OptoTest Corp.

More information

LTS-1500 Fiber Optic Test Set Operating Instructions

LTS-1500 Fiber Optic Test Set Operating Instructions LTS-1500 Fiber Optic Test Set Operating Instructions Terahertz Technologies Inc. 169 Clear Road, Oriskany, NY 13424 TEL: (315) 736-3642 FAX (315) 736-4078 E-mail sales@terahertztechnologies.com Contents

More information

LadyBug Technologies LLC Manual PowerSensor+ Field Certification Procedure

LadyBug Technologies LLC Manual PowerSensor+ Field Certification Procedure LadyBug Technologies LLC Manual PowerSensor+ Field Certification Procedure Procedure Applies to Following Power Sensors LB478A, LB479A, LB480A, LB559A, LB579A, LB589A, LB679A, LB680A Contents Purpose:...

More information

Effects of ESD and Cleaning on SFP Fiber Optic Transceivers

Effects of ESD and Cleaning on SFP Fiber Optic Transceivers Effects of ESD and Cleaning on SFP Fiber Optic Transceivers Field Service & GSC Training DOC1928793 MR Service Engineering Imagination at work Overview Optical Modules or SFP (small form-factor pluggable)

More information

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available Fiber Optic Products FIBER OPTIC PRODUCTS FIBER OPTIC PATCH CORD CABLE The Construction of a Fiber-Optic Cable Cable Jacket - The outermost layer of the fiber cable. Strengthening fibers - The strengthening

More information

CATV & DOCSIS3.0 Meter / Analyzer. Purchase from:

CATV & DOCSIS3.0 Meter / Analyzer. Purchase from: EN CATV & DOCSIS3.0 Meter / Analyzer Overview Introducing the H30. New from Televes, a go-to meter designed with the needs of a Cable TV operator in mind. The H30 is a light weight, rugged unit, packed

More information

IQOTXS Dual-Channel Single-Mode Fibre Optic Transmitter for SDI

IQOTXS Dual-Channel Single-Mode Fibre Optic Transmitter for SDI Dual-Channel Single-Mode Fibre Optic Transmitter for SDI CC Module Description The is a dual-channel Single-mode (SM) fibre optic transmitter for SDI. The unit takes two inputs of SDI at 270 Mbits/s and

More information

Cardioline Cube Stress Tango M2 Interface Notes

Cardioline Cube Stress Tango M2 Interface Notes Cardioline Cube Stress Tango M2 Interface Notes To setup Tango M2 with the Cube stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate

More information

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY 493456301 Rev B April 2009 Table of Contents Installation... 1 Setup... 2 Operation... 4 Live Video... 4 Video Settings... 5 Network

More information

Hardware installation

Hardware installation Hardware installation 5. Place and fix the OMT to the interface without tightening the screws. Figure 291: Place and fix the OMT to the interface Note: Take care to place the OMT with the engraved ARROW

More information

USER MANUEL. SNIPE 2 Ref R13

USER MANUEL. SNIPE 2 Ref R13 USER MANUEL SNIPE 2 Ref. 0141317R13 Contents 1. General Information 1-1. Introduction 1-2. Proper use and operation 1-3. Safety notes......... 2 3 3 2. Contents 2-1. Accessory included 2-2. Name of parts......

More information

PHOX TM. Camera Link Fiber Extender. Base Configuration KEY FEATURE APPLICATIONS PHOX-BM PHOX-BL-10/20/40/50

PHOX TM. Camera Link Fiber Extender. Base Configuration KEY FEATURE APPLICATIONS PHOX-BM PHOX-BL-10/20/40/50 PHOX TM KEY FEATURE Fully supports base Camera Link TM cameras/frame grabbers Provides 2Gb/s transport bandwidth up to 24 bits and 66 MHz pixel clock (85MHz optional) Zero loss and transparent transport

More information

Fiber Optics Redefined

Fiber Optics Redefined Fiber Optics Redefined Questions and Answers on the basics of fiber optic installation TECHLOGIX NETWORX Questions & Answers Questions and Answers Q: What are the two main types of fiber? A: The two main

More information

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy (steps A and B). Gain, which affects DC Accuracy, cannot

More information

Optical Component Environmental Test System

Optical Component Environmental Test System Data Sheet Optical Component Environmental Test System VIAVI Solutions The Certified VIAVI OCETS (Optical Component Environmental Test System) is the third generation of the classic OCETS, a solution customers

More information

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS T-BERD /MTS-6000, -6000A and -8000 Platforms OFI Multifunction Loss Test Module Key Features One-button automated testing, including continuity check, bidirectional

More information

Connectix Cabling Systems

Connectix Cabling Systems Connectix Cabling Systems Cabling Standards and CPR Update Connectix CEP Fibre Optic Solutions Jason Holroyd CNID Director of Business Development Types of fibre Agenda Introduction Uses Construction Transmission

More information

MTS/T-BERD 8000 Platform

MTS/T-BERD 8000 Platform Key Features New optical design for field applications 50% reduction in size and weight for true OSNR measurements in ROADM networks Full spectral range of 1250 to 1650 nm for DWDM and CWDM testing High-resolution

More information

Home Roam TV Basic User Manual

Home Roam TV Basic User Manual Page1 Home Roam TV Basic User Manual Table of Contents 1. Safety Disclaimer... 2 2. Introduction... 2 3. What s in the Box... 2 4. Specifications... 2 5. Unit Functions... 3 5-1. Transmitter Module...

More information