1 HDCS Cabling System

2

3 Asia Pacific osenberger Hochfrequenztechnik GmbH & Co was founded in Germany in 1958 and ranks among the leading manufacturers of high-speed interconnect solutions worldwide. To serve the continuous growth and demand of the global market, osenberger Asia Pacific Electronic Co., Ltd. was set up in China in With its long tradition of being the best and providing creative solutions, osenberger Asia Pacific has excelled itself and earned a great reputation in Asia Pacific region. osenberger Asia Pacific supplies product solutions to telecom-munication, Information Technology, automotive, measurement, aviation, and other industries. The product range includes F cabinet connections, HDCS cabling solutions,site Solution for base stations, In-Building Solutions, test cables, automotive products. osenberger Asia Pacific is also an expert in providing unique and bespoke product solutions with its high quality, efficient and comprehensive production and service systems. osenberger Asia Pacific, with modern manufacturing bases located in Beijing and Shanghai, the largest of its kind in Asia, is an ISO9001 quality system, ISO14001 environmental system and ISO/TS16949 automotive industry system certified company. Equipped with advanced machining, electronic plating, assembling and testing centers and other modern manufacturing facilities, staffed by a large group of talented engineers, osenberger Asia Pacific has developed its first class production lines and exercises stringent product and quality control. At present, the networks of &D, production, sales and service are extended to the whole Asia Pacific area. In the past 50 years, osenberger has established its brand all over the world. In the future, osenberger Asia Pacific will continue to provide excellent product solutions and services for its customers in the whole Asia Pacific region.

4 HDCS Premise Cabling Overview OVEVIEW 4 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

5 osenberger HDCS supports all kinds of specific customer requirement and building restriction with various technologies and flexible custom-solutions. PreCONNECT Fiber Trunk Fiber optic links with pre-terminated cables can be used on campus backbones or building backbones to take advantage of the following benefits of a Plug & Play solution: Easy ordering, only cable length, fiber count and type of connectivity system necessary Cable ends already terminated with standard compliant connectors, 100% tested Cable furcation provides no additional insertion loss by intermediate links Connectors protected by waterproof installation tube easy and time-saving installation without requiring special skills Cable divider and installation tube guarantee a tensile force >500N HDCS Cabling Technologies osenberger HDCS Fiber Technologies Field Installable Fiber Solution Fiber termination using the HDCS crimp connector system offers major advantages for horizontal and building backbone cabling: Easy connector termination either on a fiber optic buffer (diameter: 900um) or on fiberoptic cable with a diameter of 3.0mm in less than 2 minutes No epoxy needed, no time-consuming related to the epoxy fixing process No on-site polishing necessary due to pre-polished endface No electrical power supply Drect termination on HDCS premise cables & loose tube cables HDCS FIBE TECHNOLOGIES osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn 5

6 HDCS FIBE TECHNOLOGIES Fiber Optic Cable Fiber optic cable for outdoor and indoor premise cabling with 9/125 singlemode, multimode 50/125 or 62.5 and laser optimized 10 Gigabit 50/125 fiber performance. The range of fiber optic cables include the key advantages as following: Single and stranded loose tube cables up to 144 fibers for indoor and outdoor backbone applications Break-out-cables up to 24 fibers for building backbone and horizontal cabling The G.652D compliant low-water-peak singlemode fiber for all HDCS premise & loose tube singlemode cables to give future system expansion possibilities Indoor premise cables with UL approved OFN, OFNP or LSZH material sheath The attenuation and bandwidth of these cables exceed the standard level of performance to give a real future application guarantee HDCS Fiber-To-The-Desk The HDCS fiber optic outlets are designed to meet many requirements in a Fiber-To-the-Desk (FTTD) environment: Solutions for wall, channel, desk and subfloor mount available Cable guiding system to avoid exceeding the fiber optic bending radius limits Available for up to 4 fibers with standard compliant connectivity system ST, SC-Duplex, MT-J or LC-Duplex. 6 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

7 osenberger HDCS FlexField Technologies FlexField is a trademake & patent of osenberger which handles a variety of cables & connectors for G.703 Pair Cable & Coax + Baluns solution, Trunk Fiber Network + FTT solution and Ethernet Cabling System Solution. High packing density: 400 coax systems, 800-pair cable systems or mini fibers in a 2.2x0.6x0.6m rack Service friendly: the module can be always extracted minimum 30cm or up to 1.5 meters for fiber cable for maintenance All terminations are accessible from front - 19 cabinets/racks can be placed tightly side by side to a wall The SW budget of the link is guaranteed per G.703 by using multi-layer impedance controlled PCBs & connectors with correct impedance All modules fulfill EMC-standards 89/336/EEC and 92/331/EEC since all signals at the inner layers and shielding at the outer layers All modules fulfill 500V surge pulse requirement in case for telecom applications and tested to IEC HDCS FlexField TECHNOLOGIES osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn 7

8 osenberger HDCS Copper Technologies HDCS COPPE TECHNOLOGIES HDCS Copper LAN Cable Structured premises cables comply with all of the performance requirements for applications Compatible with all current connecting hardware to EN 50173, TIA/EIA568 and ISO/IEC11801 Stable construction, electrically and mechanically highquality guarantee demanding applications Exceed TIA/EIA-568-B.2 and ISO/IEC nd requirements for correlative performance by significant margins Different jacket material for all grades of anti-flame available Easy termination on the field site. HDCS Keystone Jack osenberger HDCS has a variety of jack styles available for our customers in both UTP and FTP. We have the performance levels to meet virtually any specifications from voice grade CAT.3 to CAT.5e and CAT.6. HDCS Outlet & Suface Mount Box Customer-oriented HDCS outlets, faceplates and SMB (surface mount box) are designed to provide perfect interface for data interconnection. Plane white, plane beige and angled beige faceplate provide different choices Exchangeable universal faceplates for copper CAT.3, CAT.5e, CAT.6 jacks and fiber LC, SC, ST, MT-J keystones Choice of outlet port quantity 1, 2, or 4 for faceplates, 1, 2, 4, 6 port optional for SMBs With shutter or not for surface mount box CAT.3, CAT.5e and CAT.6 jacks suitable for surface mount box Jacks passed a strict performance-testing regimen in order to ensure that they meet the NET/FET, power sum NET/FLE, eturn Loss and Attenuation requirements of their respective performance level HDCS jacks have earned the UL verified mark at the highest levels of performance including CAT.5e and CAT.6 component level All the jacks are designed for easy termination with both standard 110-style tool and KONE tool osenberger HDCS keystone style jacks are suitable for mounting in all HDCS faceplates, surface mount boxes and patch panels 8 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

9 Content HDCS Fiber Optic Solutions Fiber Optic Cable PreCONNECT Fiber Optic Trunk Fiber Optic Patch Panel Fiber Optic Cable Assembly Fiber Optic Connector Adapter & Coupler Fiber-To-The-Desk Installation Tool & Accessory 43 HDCS Copper Solutions osenberger HDCS LAN Cable Keystone & Module HDCS Outlet & Faceplate Patch Panel osenberger HDCS 110 System LAN Jumper & Plug Installation Tool & Accessory 77 FlexField Solutions FlexField Module FlexField Subrack FlexField Accessory 85 HDCS Glossary - Premise Cabling 86 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn 9

10 HDCS Fiber Optic Solutions Fiber Optic Cable 12 PreCONNECT Fiber Optic Trunk 23 Fiber Optic Patch Panel 26 Fiber Optic Cable Assembly 28 Fiber Optic Connector 32 Adapter & Coupler 39 Fiber-To-The-Desk 41 Installation Tool & Accessory 43

11 HDCS Products & Solutions

12 FIBE OPTIC CABLE osenberger HDCS provides customer with fiber optic cables for premise cabling solutions which are designed to exceed the standard requirements of IEC11801, EN50173 and EIA/TIA568B. The performance of cabling system is determined by the key parameters such as attenuation and bandwidth. The optical output power is reduced continuously when light is propagating down an optical fiber. This signal decrease scaled to length is measured in db/km. Low attenuation values allow longer link distances without a reduction of system performance or active signal amplification. Bandwidth is the parameter which refers to the data transfer capacity. It is generally decreasing with increasing cable length. A fiber optic multimode cable is specified by the HDCS Optical Fiber Specification bandwidth-length product in MHz/km. Due to different physical behaviour the bandwidth of singlemode fibers can be calculated from the pulse dispersion given in ps/(km.nm) if the spectral width of the light source in nm is known. Properties UNIT E9/125 (LWP) G50/125 G62.5/125 LOF150 LOF300 LOF550 Core diameter [ m] Cladding diameter [ m] Diameter primary coating [ m] Numerical aperture Core-cladding concentricity [ m] Attenuation 850 nm [db/km] nm [db/km] nm [db/km] nm [db/km] nm [db/km] Bandwidth 850 nm [MHz/km] nm [MHz/km] Cladding non-circularity [%] Fatigue coefficient (typical) osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

13 Outdoor Fiber Optic Cable Outdoor Loose Tube Light Duty Non-metallic Cable Application Backbone connection between buildings Other fiber optic connections in the outdoor area Features and Benifit High tensile strength and crush resistance Longitudinally and transversely water proof by gel-filled loose tubes Outer sheath made of PE, resistance of UV radiation Up to 144 fibers capacity Specification Mechanical Characteristic Number of Cable Diameter Cable Max. Tensile Min. Bending Min. Bending Crush Fibers (ef.) Weight Load adius adius esistance (Installation) (Operation) [mm] [kg/km] [N] [mm] [mm] [N/10cm] (single) (single) (single) (single) (single) (stranded) (stranded) (stranded) Cable Construction FIBE OPTIC CABLE PE outer jacket Aramid yarn strength member [keviar] Fiber PBT tube Water bloking compound Tube s color ed Other Tube s color Natural Tube s color Yellow Water blocking compound Core wrap Subunit [PBT Tube] Strength member [FP] PE outer jacket Environmental Specifications Temperature ange [ ] (transport and storage) -40 to + 70 Temperature ange [ ] (installation) -20 to + 70 Temperature ange [ ] (operation) -40 to + 70 Ordering Information Number Part Number of Fibers E9/125u G50/125 G62.5/125 98A074-98A075-98A076- osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

14 FIBE OPTIC CABLE Outdoor Loose Tube Heavy Duty Armored Cable Application Backbone connection between buildings Other fiber optic connections in the outdoor area Direct burial & duct application Features and Benefit Outer sheath made of PE, resistance of UV radiation Excellent tensile strength and crush resistance Longitudinally and transversely water proof gel-filled loose tubes Up to 144 fibers capacity Specification Mechanical Characteristic Number of Cable Diameter Cable Max. Tensile Min. Bending Min. Bending Crush Fibers Weight Load adius adius esistance (Installation) (Operation) [mm] [kg/km] [N] [mm] [mm] [N/10cm] (single) (single) (single) (single) (stranded) (stranded) (stranded) (stranded) (stranded) (stranded) (stranded) Combustion Energy [MJ/m] Cable Construction Strength member [FP] PBT tube Gel filling Fiber Aramor tape PE outer jacket Water blocking compound Aramid strength member [kevlar] Strength member [FP] Core wrap Aramor tape PE outer jacket Subunit [PBT Tube] Environmental Specifications Temperature ange [ ] (transport and storage) -40 to + 70 Temperature ange [ ] (installation) -20 to + 70 Temperature ange [ ] (operation) -40 to + 70 Ordering Information Number Part Number of Fibers E9/125u 98A077- G50/125 98A078- G62.5/125 98A osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

15 Outdoor Loose Tube Light Duty Armored Cable Application Backbone connection between buildings Other fiber optic connections in the outdoor area Direct burial & duct application Feature and Benefit High tensile strength and crush resistance Longitudinally and transversely water proof by gel-filled loose tubes Up to 144 fibers capacity Specification Mechanical Characteristic Number of Cable Diameter Cable Max.Tensile Min. Bending Min. Bending Crush Fibers Weight Load adius adius esistance (Installation) (Operation) [mm] [kg/km] [N] [mm] [mm] [N/10cm] [MJ/m] (single) (single) (single) (single) (single) (stranded) (stranded) (stranded) (stranded) (stranded) (stranded) Combustion Energy FIBE OPTIC CABLE Cable Construction PE outer jacket Armor tape PE inner jacket Aramid strenght PBT tube Water bloaking compound Tube s color yellow Tube s color red Other tube s color natural Water blocking compound Core wrap Dielectric strength member Armor Subunit PE outer jacket Environmental Specifications Temperature ange [ ] (transport and storage) -40 to + 70 Temperature ange [ ] (installation) -20 to + 70 Temperature ange [ ] (operation) -40 to + 70 Ordering Information Number of Fibers E9/125u 98A080- Part Number G50/125 98A081- G62.5/125 98A082- osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

16 FIBE OPTIC CABLE Outdoor SM/MM Hybrid Non-metallic Cable Application Campus backbone cabling Duct application Feature and Benefit osenberger outdoor fiber optic cable, hybrid SM and MM exceed TIA/EIA-568-B, ISO/IEC11801 and EN50173 requirements. Good EMI-resistant, flexible and small bending radius, good crush resistant, longitudinally water resistant Specification Cable Construction Mechanical Characteristic SM subunit yellow MM subunit orange Core wrap Aramid yarns Water blocking compound PE outer jacket Strength member (FP) Weight: 120 kg/km Nominal Diameter: 11.1mm Mini-bending radius: 110mm for long term and 220mm for installation Max loading: 700N Crush: 500N/10cm Temperature characteristic Transport and storage: - 40 to + 70 Installation: - 20 to + 70 Operation: - 40 to + 70 Ordering Information Part Number Description 98A Fiber Cable Outdoor, Non-metal, 6x9u+6x50u 98A Fiber Cable Outdoor, Non-metal, 6x9u+6x62.5u 16 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

17 Outdoor SM/MM Hybrid light Duty Armored Cable Application Campus backbone cabling Duct and direct-buried application Feature and Benefit This cable is good with small bending radius and flexibility with the fibers in the tube, good crush resistant, longitudinally water resistant. Specification Cable Construction Mechanical Characteristic Weight: 120 kg/km Nominal diameter: 11.1mm Mini-bending radius: 110mm for long term and 220mm for install Max loading: 700N Crush: 500N/10cm Temperature Characteristic Transport and storage: - 40 to + 70 Installation: - 20 to + 70 Operation: - 40 to + 70 Ordering Information SM subunit yellow MM subunit orange Core wrap Armored tape Water blocking compound PE outer jacket Strength member (FP) FIBE OPTIC CABLE Part Number Description 98A Cable Outdoor, LD Armored, 6x9u+6x50u 98A Cable Outdoor, LD Armored, 6x9u+6x62.5u osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

18 FIBE OPTIC CABLE GYTA53 Direct Buried Armored Fiber Cable Feature and Benefit The osenberger GYTA53 armored heavy duty outdoor fiber optical cable can be for long-distance telecommunication application, as trunk cables between telecommunication central stations and campus backbone. This cable has a small bending radius and good flexibility with the fibers in the tube, excellent tensile and crush resistance performance, and is longitudinally water-resistant and moisture proof. It can be up to 144 fibers capacity. Cable Construction Profile Mechanical Characteristic Fibers count Cable diameter nominal (mm) Cable weight approx. (kg/km) Elements color Fiber color Nominal inner sheath thickness Nominal outer sheath thickness Corrugated steel tape armor Min.bending radius short term long term Tensile strength Installation long term Crush resistance Operation temperature Storage temperature Installation temperature Shipping length Ordering Information PE outer jacket Plastic coated corrugated steel tape Loose tube Filler core filling compound Cable core filling compound Central strength member option on FP or steel Polyethlene layer over CSM (as required) Optic fibers Core wrapping AE/PE laminated tape (moisture barrier) PE inner jacket Kevlar strengh member options (5 bundles each side under the corrugated steep tape) Option An longitudinally placed identification tape marked with customer name to be placed with the cable. Alternatively it can be printed in core wrapping or on polyethylene layer over the central strength member. 2~48 50~72 74~84 86~96 98~ ~ ~ ~ Blue, Orange, natural for the remainder Blue, Orange, Green, Brown, Grey, White, ed, Black, Yellow, Violet, Pink, Aqua (EIA-598) Minimum 1.0 mm Minimum 2.0 mm 0.15+/-0.02 mm with copolymer film coated at both side of 0.05mm thickness 20 times cable O.D 10 times cable O.D 3000N 1000N 3000N/10cm (Installation) -40 ~ ~ ~ meters per drum or per customer specification Part Number 98A133-xxx 98A134-xxx Description Outdoor armored fiber cable, direct buried, 9/125um, G652D, xxx fibers Outdoor armored fiber cable, direct buried, 9/125um, G655, xxx fibers 18 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

19 Outdoor SWA Armored Direct-Buried Heavy Duty Cable Application Direct buried for long-distance communication, as trunk cables between telecommunication central stations or as campus backbone. Specification Mechanical Characteristic Number of Cable Diameter Cable Weight Max Tensile Min. Bending Min. Bending Crush Fibers Load adius adius esistance (Operation) [mm] [kg/km] [N] [mm] [mm] [N/10cm] Cable Construction Profile Fillers Feature and Benefit This cable has a small bending radius, excellent tensile and crush resistance performance, and is longitudinally water-resistant and moisture-proof. It can be up to 144 fibers capacity. Fiber Steel wire (CSM) Loose tube PET tape Jeliy filled AI tape PE Inner sheath Galvanized sheath MDPE outer sheath FIBE OPTIC CABLE Temperature Characteristic Transport and storage: - 40 to + 70 Installation: - 20 to + 70 Operation: - 40 to + 70 Ordering Information Number of Fibers E9/125u 98A039- Part Number G50/125 98A040- G62.5/125 98A041- osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

20 FIBE OPTIC CABLE HDCS Universal Fiber Optic Cable Application Multifiber backbone connections within and between buildings Fiber optic cabling in data centers Connections between main and end distributors Specification Mechanical Characteristic Feature Out sheath is made of LSZH material, comply with IEC , , , Longitudinally water-resistant and moisture-proof by use of gel-filled loose tubes, can select non-metallic rodent protection as option. Up to 144 fibers capacity Number of Cable Diameter Cable Weight Max Tensile Min. Bending Min. Bending Crush Fibers Load adius adius esistance (Installation) (Operation) [mm] [kg/km] [N] [mm] [mm] [N/10cm] 1x x x x x x x x x x Cable Construction Profile LSZH outer oacket Armid yarns Gel-filled, central loose tube Fiber Water blocking compound LSZH outer jacket Armid yarns Gel-filled, loose tube Wrap tape Blind or fiber Temperature Characteristic Transport and storage: - 25 to + 70 Installation: - 20 to + 60 Operation: - 5 to + 50 Ordering Information FP Number of Universal Cable LSZH, Kevlar Universal Cable LSZH, odent Protection Fibers E9/125um G50/125 G62.5/125 E9/125um G50/125 G62.5/125 1x x x x x x x x x x A 21132A 21133A 21121A 21122A 21123A 20 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

21 FTTD Fiber Optic Cable Application Flexible horizontal cabling Connection to active components Fiber-To-The-Desk (FTTD) Building Backbone (premise cable) Features and Benefit Indoor cable has good flame-retardant property and out sheath can be made of iser, Plenum or LSZH UL approved (OFN, OFNP) Available from 1 to 24 fibers Suited for field connector termination NO.2 NO.3 Structure 1 NO.1 Specification Premise and FTTD Cable (Tight buffer type, OFN rated) Aramid yarn strength member [ kevlav] 900um tight buffer Outer shealth OFN/OFNP/LSZH Central strength member [ FP] Subunit sheath Number of Cable Diameter Cable Weight Max Tensile Min. Bending Min. Bending Crush Fibers Load adius adius esistance (Installation) (Operation) [mm] [kg/km] [N] [mm] [mm] [N/10cm] (zipcord) (premise) (premise) (premise) (premise) (premise) (premise) Polyester Outer shealth OFN/OFNP/LSZH NO.4 kevlav filler as optional Structure 2 Aramid yarn strength member [ kevlav] FIBE OPTIC CABLE Ordering Information OFN ated Cable Simplex Zipcord 2-Fiber 4-Fiber 6-Fiber 8-Fiber 12-Fiber 24-Fiber 9/125um 98A004 98A050 98A A A A A A /125um 98A008 98A049 98A A A A A A OM3 50/125um (LT150) - 98A A A A A A A OM3 50/125um (LT300) - 98A A A A A A A /125um - 98A048 98A A A A A A osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

22 FIBE OPTIC CABLE Premise and FTTD Cable (Tight buffer type, LSZH rated) Number of Fibers Cable Diameter Cable Weight Max Tensile Min. Bending Min. Bending Crush Load adius adius esistance (Installation) (Operation) [mm] [kg/km] [N] [mm] [mm] [N/10cm] (zipcord) (premise) (premise) (premise) (premise) (premise) (premise) Ordering Information OFN ated Cable Simplex Zipcord 2-Fiber 4-Fiber 6-Fiber 8-Fiber 12-Fiber 24-Fiber 9/125um 98A028 98A017 98A A A A A A /125um 98A062 98A093 98A A A A A A OM3 50/125um (LT150) - 98A OM3 50/125um (LT300) - 98A /125um 98A029 98A019 98A A A A A A Premise and FTTD Cable(Tight buffer type, Plenum rated) Number of Fiber 1 Cable Diameter Cable Weight Max. Tensile Min. Bending Min. Bending Crush Load adius adius esistance (Installation) (Operation) [mm] [kg/km] [N] [mm] [mm] [N/10cm] (zipcord) (premise) (premise) (premise) (premise) (premise) (premise) Ordering Information OFN ated Cable Simplex Zipcord 2-Fiber 4-Fiber 6-Fiber 8-Fiber 12-Fiber 24-Fiber 9/125um A A A A A A /125um A A A A A A OM3 50/125um (LT150) - 98A OM3 50/125um (LT300) - 98A /125um 98A131 98A027 98A A A A A A osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

23 2 PreCONNECT Fiber Optic Trunk Application Fibers Campus backbone cabling Available with 4 to 144 fibers of the types 9/125, Industrial plant cabling 50/125, 62.5/125,10G 150m and 10G 300m. Fiber optic cabling in data centers Features and Benefit Connectivity Systems FC, SC, ST, LC (ceramic ferrule) Quick and flexible installation on site with use of a variety of pre-manufactured components eduction in installation time within security areas Fiber and connector surface are being protected by use of waterproof, as well as torsion and crush resistant, installation tubes Cable divider and installation tube guarantee a tensile MT-J, SC-DC (Small Form Factor, epoxy-compound ferrule) MTP/MPO Fiber Assignment No crossover or crossover within each channel Numerical and color code assignment Delivery force >500N Up to length of 40M, cardboard box ( cm 3 ) Optical Cable For cable length 40M, Mounted on cardboard Fiber optic cable with central or stranded loose tube construction, non-metallic strain relief. Fiber optic cable with Polyethylen (PE)-sheath for outdoor installation drum outer diameter: 80cm, width 30cm or on matching wooden drum Installation guide enclosed Attenuation measurement protocols enclosed Fiber optic cable with LSZH sheath for indoor installation, specified acc. to IEC , IEC , IEC PreCONNECT FIBE OPTIC TUNK osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

24 PreCONNECT FIBE OPTIC TUNK Pre-terminated Cables for Outdoor Application Application Backbone connections between buildings primary area Application in the industrial field Specification Technical Characteristic Ordering Information Pre-terminated Cables for Outdoor Application 201 1: Fiber E9/125um Feature Cable with loose tube construction, out sheath made of Polyethylen (PE), high tensile strength and crush resistance Non-metallic strain relief elements Longitudinally and transversely waterproof due to water blocking fleece and gel-filled loose tubes Non-metallic rodent protection Cable lengths: up to 2000m Number of Fibers Length of legs [cm] Diameter Installation Tube [mm] Max. Tensile Force Installation Tube [N] Max. Tensile Force Cable [N] Min. Bending adius (Installation) [mm] Min. Bending adius (Operation) [mm] Crush esistance Installation Tube [N/cm] 100 Crush esistance Cable [N/cm] 300 Diameter Cable Drum [mm] 800 Temperature ange (Installation) [ ] 0 to +50 Temperature ange (Operation) [ ] -20 to +60 osenberger s pre-terminated cables for outdoor application are ordered using three digits: Digit1, Fiber type selection; Digit2, Connector type selection; Digit3, number of fibers selection, the format and digits are listed below. 1: SC/SC 1: 4 fibers 2: Fiber G50/125um 2: ST/ST 2: 6 fibers 3: Fiber G62.5/125um 3: SC/ST 3: 8 fibers 4: 10G 150m 4: FC/FC 4: 12 fibers 5: 10G 300m 5: SC-DC/SC-DC 5: 16 fibers 6: MTJ/MTJ 6: 24 fibers 7: LC/LC 7: 36 fibers 8: FC/ST 8: 48 fibers 9: FC/FC-APC 9: 72 fibers A: LC/SC B: FC/SC C: FC-APC/FC-APC A: 144 fibers 24 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

25 Pre-terminated Cables for Indoor Application Application Multifiber backbone connections within building Secondary and tertiary area from the floor distributor to the workplace Fiber optic cabling in data centers Specification Technical Characteristic Feature Cable with loose tube construction, out sheath made F-LSZH material, non-metallic strain relief elements Optionally with rodent protection Longitudinally and transversely water proof due to water blocking fleece and gel-filled loose tubes Flame retardant acc. to IEC and IEC Cat.C No corrosive gas emission acc. to IEC Low smoke emission acc. to IEC Installation tube acc. to IP50, dust protected, crush resistant Number of Fibers Length of Legs [cm] Diameter Installation Tube [mm] Max. Tensile Force Installation Tube [N] Max. Tensile Force Cable [N] Min. Bending adius (Installation) [mm] Min. Bending adius (Operation) [mm] Crush esistance Installation Tube [N/cm] Crush esistance Cable [N/cm] Diameter Cable Drum [mm] Temperature ange (Installation) [ ] Temperature ange (Operation) [ ] Pre-terminated Cables for Outdoor application to to +60 1: Fiber E9/125um 1: SC/SC : 4 fibers 2: Fiber G50/125um 2: ST/ST 2: 6 fibers 3: Fiber G62.5/125um 3: SC/ST 3: 8 fibers 4: 10G 150m 4: FC/FC 4: 12 fibers 5: 10G 300m 5: SC-DC/SC-DC 5: 16 fibers 6: MTJ/MTJ 6: 24 fibers 7: LC/LC 7: 36 fibers 8: FC/ST 8: 48 fibers 9: FC/FC-APC 9: 72 fibers A: LC/SC B: FC/SC C: FC-APC/FC-APC A: 144 fibers PreCONNECT FIBE OPTIC TUNK osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

26 3 Fiber Optic Patch Panel FIBE OPTIC PACTH PANEL HDCS patch panels are designed for installation in 19 racks ready to accept all common types of factory or on-site assembled cables. Especially suited to accept osenberger factory assembled Pre-Connect cabling system. Features and Benefit osenberger HDCS distribution & splice panel insures the four critical elements of fiber optical cable management: bend radius protection, cable routing paths, cable access and physical protection. All these four aspects directly affect the reliability, functionality, and the operational cost of the network. Sliding-type Splice Patch Panel High density and large capacity for saving space of main room Good dust-proof performance The panel surface is treated with electro-static spraying Screen print front plate labeling Cable guidance 45 slant backwards, lead way choiceable Aluminum or steel body form available Sliding-type and fixed-type available Standard black color coated and other colors available Panel accessories can be ordered separately Sliding-type Distribution Patch Panel Specification/Dimension Sliding type: 483 x 300 x 1HU (mm) and 483x 300 x 2HU (mm) Fixed type: 483 x 250 x 1HU (mm) and 483x 250 x 2HU (mm) Delivery Form Panel completely factory assembled Dummy plugs in unused cable inputs Dummy plugs in unused front plate ports Not supplied with splice holders/protectors (these have to be ordered separately) Adapters mounted for complete panel set 4 installation screws and nuts attached Cable gland&guiding clip Splice trays included for complete panel set 26 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

27 Ordering Information HDCS Fiber Optic Patch Panel 10 Patch Panel Type 1: 1 HU Distribution Panel 2: 1 HU Splice Panel 3: 1 HU Sliding Distribution Panel 4: 1 HU Sliding Splice Panel 5: 2 HU Distribution Panel 6: 2 HU Splice Panel 7: 2 HU Sliding Distribution Panel 8: 2 HU Sliding Splice Panel HDCS Panel Accessory Adapter Type 1: SC/SC Simplex,SM 2: ST/ST Simplex 3: ST/ST Duplex 4: SC/SC Simplex, MM 5: SC/SC Duplex, S/M 6: SC/SC Duplex, M/M 7: SC/ST Duplex, S/M 8: SC/ST Duplex, MM 9: ESCON/ST, MM A: MT-J/MT-J, SM B: MT-J/MT-J, MM C: LC/LC, Duplex, SM D: LC/LC, Duplex, MM E: FC/FC, Simplex G: SC/APC, Simplex Fiber Counts 1: 0 Fiber 2: 12 Fibers 3: 24 Fibers 4: 48 Fibers 5: 16 Fibers 6: 8 Fibers 7: 32 Fibers 8: 4 Fibers 9: 256 Fibers A: 288 Fibers B: 512 Fibers C: 6 Fibers Item HDCS PN Description Unit Splice tray (12-fiber) ea 2 99P2005 Splice holder (single-fiber) ea 3 99P2006 Splice holder (ribbon-fiber) ea 4 99P mm cable protecting tube m PG13.5 cable gland ea PG16 cable gland ea PG21 cable gland ea Cable clamping adapter ring (21/16mm) ea Cable clamping adapter ring (21/13.5mm) ea Cable guiding clip ea SC-duplex blank cover for panel port ea ST/FC simplex black cover for panel port ea MT-J/SC simplex blank cover for panel port ea Panel Color 0: Metal 2: Grey 3: White 4: Beige 5: Black Structure Code 1: Aluminum body & front plate 1A: Steel body & front plate FIBE OPTIC PACTH PANEL osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

28 4 Fiber Optic Cable Assembly FIBE OPTIC CABLE ASSEMBLY Fiber optic patch cords and pigtails, both simplex and duplex versions, are mainly used to link up with patch panels and connect outlets and work terminals. Fiber optic pigtails, which are supplied with a connector on one side, are used when dividing up multifiber optic cables by splicing. Preferred are fiber optic cables, that are flame retardant and have halogen free jacket. The connectors attached to the cable meet the various standards according to IEC. Fixing of the fiber in the ferrule is done using an epoxy glue process. A highly developed polishing procedure for PC/APC cuts, as well as the cuts of multifiber connectors, guarantees a minimum insertion loss, as well as a high return loss. The excellent optical and mechanical properties ensure a long lifetime of the assemblies. The manufacturing process is being controlled 100% of the time through constant supervision of the protocols of all individual piece. 28 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

29 Patch Cord Application Channel to channel connection of fiber optic lines installed within distribution panels Connection of peripheral devices with a fiber optic interface Property Out sheath made of riser, plenum or F-LSZH material The following cable constructions are being supplied: Simplex cable, duplex cable, mini-zipcord cable, ribbon cable Other types of cables on request Fibers/Cable available of the types 9/125um, 50/125um, 62.5/125um, Connectivity System osenberger patch cords can be delivered with the following connectors: ST, SC, FC, LC, MU, MTJ, MTP, ESCON, SCDC, E2000 and DIN Delivery Patch cord separately packed in plastic bag Labeled with serial number 100% tested with data Technical Data Insertion loss determined acc. to IEC Measurement across both connectors 10G 150m, 10G 300m and 10G 550m Cable Property Number of Fibers Cable construction Simplex Duplex Mini-Zip-Cord Cable cross section 2.9mm mm mm Max tensile strength Max. crush resistance [N/cm] Min. bending radius [mm] Temperature ange Storage: -25 ~ +70 In operation: -5 ~ +70 FIBE OPTIC CABLE ASSEMBLY osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

30 Pigtail um um um FIBE OPTIC CABLE ASSEMBLY Singlemode Patch cord or Pigtail 98C 98C Digit1 S: SM iser E: SM LSZH I: SM Plenum P: SM G655 iser onnector type selection; Digit2 Digit3 Digit4 Digit5 Digit6 Digit7 Digit8 2: 2mm 0: Pigtail 1: UPC-UPC 1: ST 1: ST 3: 3mm 1: Patchcord 2: Null 2: SC 2: SC 6: 1.6mm 2: Duplex pigtail 3: APC-APC 3: FC 3: FC 8: 1.8mm 3: Duplex patchcord 4: PC-APC 4: LC 4: LC 9: 0.9mm 4: Duplex pigtail 5: APC-PC 5: MU 5: MU (separately) 6: MT-J(F) 6: MT-J(F) 5: Duplex patchcord 7: MT-J(M) 7: MT-J(M) (separately) 8: MTP(F) 8: MTP(F) 9: E2000 9: E2000 A: FSMA A: FSMA B: MTP(M) B: MTP(M) C: ESCON C: ESCON D: SCDC D: SCDC M: meter F: feet Cable length. meter Cable length. feet 30 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610)

31 Multimode Patch Cord or Pigtail 98C Digit1 Digit2 Digit3 Digit4 Digit5 Digit6 Digit7 Digit8 M: MM iser 2: 2mm 0: pigtail 5: 50/125 F: MM LSZH 3: 3mm 1: patchcord 6: 62.5/125 M: meter J: MM Plenum 6: 1.6mm 2: Duplex pigtail 7: 100/140 G: 10G iser 8: 1.8mm 3: Duplex patchcord F: feet (LT=300m) 9: 0.9mm 4: Duplex pigtail H: 10G LSZH (separately) 98C (LT=300m) 5: Duplex patchcord N: 10G Plenum (separately) (LT=300m) Q: 10G iser (LT=150m) : 10G LSZH (LT=150m) T: 10G Plenum (LT=150m) 1: ST 1: ST 2: SC 2: SC 3: FC 3: FC 4: LC 4: LC 5: MU 5: MU 6: MT-J(F) 6: MT-J(F) 7: MT-J(M) 7: MT-J(M) 8: MTP(F) 8: MTP(F) 9: E2000 9: E2000 A: FSMA A: FSMA B: MTP(M) B: MTP(M) C: ESCON C: ESCON D: SCDC D: SCDC Cable length. meter Cable length. feet Singlemode Patch Cord or Pigtail (Multifiber) 98C Digit1 Digit2 Digit3 Digit4 Digit5 Digit6 Digit7 Digit8 A: SM ribbon A: 2 core 0: pigtail 1:UPC-UPC 1: ST 1: ST Cable length C: SM breakout B: 4 core 1: patchcord 2:Null 2: SC 2: SC M: meter. meter C: 6 core 2: Duplex pigtail 3:APC-APC 3: FC 3: FC Cable length F: feet D: 8 core 3: Duplex patchcord 4:PC-APC 4: LC 4: LC. feet E: 12 core 4: Duplex pigtail 5:APC-PC 5: MU 5: MU F: 24 core (separately) 6: MT-J(F) 6: MT-J(F) 98C G:36 core 5: Duplex patchcord 7: MT-J(M) 7: MT-J(M) H:48 core (separately) 8: MTP(F) 8: MTP(F) 9: E2000 9: E2000 A: FSMA A: FSMA B: MTP(M) B: MTP(M) C: ESCON C: ESCON D: SCDC D: SCDC Multimode Patch Cord or Pigtail (Multifiber) 98C Digit1 Digit2 Digit3 Digit4 Digit5 Digit6 Digit7 Digit8 B: MM ribbon A: 2 core 0: pigtail 5: 50/125 1: ST 1: ST Cable length M: meter D: MM breakout B: 4 core 1: patchcord 6: 62.5/125 2: SC 2: SC. meter C: 6 core 2: Duplex pigtail 7: 100/140 3: FC 3: FC Cable length 3: Duplex patchcord 4: LC 4: LC F: feet D: 8 core. feet E: 12 core 4: Duplex pigtail 5: MU 5: MU F: 24 core (separately) 6: MT-J(F) 6: MT-J(F) 98C G:36 core 5: Duplex patchcord 7: MT-J(M) 7: MT-J(M) H:48 core (separately) 8: MTP(F) 8: MTP(F) 9: E2000 9: E2000 A: FSMA A: FSMA B: MTP(M) B: MTP(M) C: ESCON C: ESCON D: SCDC D: SCDC FIBE OPTIC CABLE ASSEMBLY osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

32 FIBE OPTIC CONNECTO um um um Insertion Loss Singlemode Multimode Typical Maximum 0.20dB 0.40dB 0.20dB 0.40dB Insertion loss change after 1000 mating cycles: 0.2dB Temperature range: , 40 cycles, change of insertion loss: <0.3dB Max. tension: 88N- attenuation change: 0.2dB eturn Loss: for SM 45dB Cable Adaption Available for: 0.9mm semi-tight buffered fiber 2.0mm simplex/duplex cable 2.9mm simplex/duplex cable Other cable adaptions upon request Ordering Information Cable Diameter Singlemode Boot Color Multimode Boot Color 0.9mm 98F01-22 Yellow 98F01-21 Black 2.0mm 98F01-24 Yellow 98F01-23 Black 3.0mm 98F01-26 Yellow 98F01-25 Black * Other colored boots and connectors available 32 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

33 SC Fiber Optic Connector Property EN recommended connector With push-pull-locking mechanism SC specification according to TIA/EIA 568 and IEC Fiber Type Multimode: G62.5/125um, G50/125um Singlemode: E9/125um Material Ferrule: Zirconia ceramic Connector body: composite plastic Housing color: Blue - singlemode 0 Green - singlemode 8 Beige - multimode Insertion Loss Singlemode Multimode Typical Maximum 0.20dB 0.40dB 0.20dB 0.40dB Insertion loss change after 1000 mating cycles: 0.2dB Temperature range: , 40 cycles, change of insertion loss: <0.3dB Max. tension: 88N- attenuation change: 0.2dB eturn Loss: for SM UPC 45dB for SM APC 60dB Cable Adaption Available for: 0.9mm semi-tight buffered fiber 2.0mm simplex/duplex cable 2.9mm simplex/duplex cable Other cable adaptions upon request FIBE OPTIC CONNECTO Ordering Information Cable Diameter Singlemode UPC Singlemode APC Multimode 0.9mm buffer 98F F F mm simplex 98F F F mm simplex 98F F F mm duplex 98F F mm duplex 98F F02-83 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

34 FC Fiber Optic Connector FIBE OPTIC CONNECTO Property FC specification according to IEC Twist protection pin End face geometry ferrule: convex FC-APC angled with 8 Fiber Type Multimode: G62.5/125um, G50/125um Singlemode: E9/125um Material Ferrule: Zirconia ceramic Connector body: brass, nickel plated Insertion Loss Singlemode Multimode Typical 0.20dB 0.20dB Maximum 0.40dB 0.40dB Insertion loss change after 1000 mating cycles: 0.2dB Temperature range: , 40 cycles, change of insertion loss: <0.3dB Max. tension: 88N- attenuation change: 0.2dB eturn Loss: for SM UPC 45dB for SM APC 60dB Cable Adaption Available for: 0.9mm buffered fiber 2.0mm simplex/duplex cable 2.9mm simplex/duplex cable Other cable adaptions upon request Ordering Information Cable Diameter Singlemode UPC Boot Color Singlemode APC Boot Color Multimode Boot Color 0.9mm buffer 2.0mm 3.0mm 98F F F03-18 Yellow Yellow Yellow 98F F F03-12 Green Green Green 98F F F03-17 Black Black Black 34 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

35 LC Fiber Optic Connector Feature Small Form Factor connectivity system, high end cabling for Telecom and LAN Fiber Type Multimode: G62.5/125um, G50/125um Singlemode: E9/125um Material Ferrule: Zirconia ceramic Connector body: composite plastic Housing color: Blue - singlemode 0 Green - singlemode 8 Beige/Black - multimode Insertion Loss Singlemode Multimode Typical 0.10dB 0.10dB Maximum 0.30dB 0.30dB Insertion loss change after 500 mating cycles: 0.2dB Temperature range: , 40 cycles, change of insertion loss: <0.3dB eturn Loss: for SM UPC 45dB SM APC 60dB Cable Adaption Available for: 0.9mm buffered fiber 1.6 ~ 2.0mm simplex/duplex cable 2.9mm simplex/duplex cable Other cable adaptions upon request Ordering Information Cable Diameter Singlemode UPC Boot Color Singlemode APC Boot Color Multimode Boot Color 0.9mm buffer 98F04-01 White 98F04-32 Green 98F04-03 White 1.6~2.0mm simplex 98F04-04 Blue 98F04-31 Green 98F04-05 Black 1.6~2.0mm simplex 98F04-23 White F04-06 White 1.6~2.0mm duplex 98F04-24 Blue 98F04-42 Green 98F04-08 Black 1.6~2.0mm duplex 98F04-07 White F04-09 White 2.9mm simplex 98F04-38 Blue 98F04-33 Green 98F04-39 White 2.9mm duplex 98F04-40 Blue 98F04-34 Green 98F04-41 White FIBE OPTIC CONNECTO * Other colored boots and connectors available osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

36 MU Fiber Optic Connector FIBE OPTIC CONNECTO Feature Small Form Factor connectivity system, mainly used for backplane connection With push-pull mechanism Fiber Type Multimode: G62.5/125um, G50/125um Singlemode: E9/125um Material Ferrule: Zirconia ceramic, diameter 1.25mm Connector body: composite plastic Housing color: Brown - singlemode Brown - multimode Ordering Information Insertion Loss Singlemode Multimode Typical Maximum 0.20dB 0.40dB 0.20dB 0.40dB Insertion loss change after 200 mating cycles: 0.2dB Temperature range: , 100 cycles, change of insertion loss: <0.3dB eturn Loss: for SM UPC 45dB Cable Adaption Available for: 0.9mm buffered fiber 2.0mm simplex/duplex cable Other cable adaptions upon request Cable Diameter Singlemode UPC Boot Color Multimode Boot Color 0.9mm buffer 98F05-01 Greyish Blue 98F05-02 Greyish Blue 2.0mm simplex 98F05-03 Greyish Blue 98F05-04 Greyish Blue 2.0mm duplex 98F05-06 Greyish Blue 98F05-08 Greyish Blue 36 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

37 MTJ Fiber Optic Connector Feature MTJ connector system offers an increase in packing density of 50%. The ferrule of an MTJ connector, unlike the common ST and SC connectors, encompasses 2 fibers. The MTJ connectors belong to the category of the Small Form Factor connector (SFF). Compatible to the copper based J-45 interface. The compatibility of J-45 with MTJ systems supports a simple and defined change over from copper technology to fiber optic technology (e.g. Fiber To The Desk), without changing the distribution panels and outlets. Application MTJ interfaces of active components: transceiver, switches, hubs, made by the following manufacturers: e.g. 3Com Corp., Hewlett-Packard, Cisco Systems, Nortel Networks, AMP, Cabletron Systems, Fujikura. Passive cabling systems: PreCONNECT Fiber Type Multimode: G62.5/125um, G50/125um Singlemode: E9/125um Material Ferrule: composite with 2 holes(125um) fiber distance 750 m Two connectors are aligned by guiding pins Connector body: composite plastic Structure: flat polished ferrule with fiber protrusion Insertion Loss Singlemode Multimode Typical 0.35dB 0.35dB Maximum 0.60dB 0.60dB Cable Adaption Available for: 2 fiber ribbon cable (diameter 2.9mm) 1.8mm Mini-zipcord cable FIBE OPTIC CONNECTO Ordering Information Cable Diameter Singlemode 2.9mm/1.8mm Male Female Male Mini-zipcord 98F F F06-12 Multimode Female 98F06-11 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

38 FIBE OPTIC CONNECTO : G62.5/125um, G50/125um : E9/125um Singlemode 0.20dB 0.60dB Multimode 0.20dB 0.45dB Ordering Information Cable Diameter Singlemode Multimode 12F ribbon Male 98F08-08 Female 98F08-04 Male 98F08-05 Female 98F osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

39 6 Adapter & Coupler The fiber optic couplers are used to link fiber optic connectors terminated on a fiber optic cable and are usually mounted in 19 patch panels and wall outlets. HDCS couplers provide a save, low Insertion Loss interconnection because the fiber is precisely aligned by a ceramic sleeve. The metal body ST- and SC-couplers guarantee a high mechanical long-term stability and reproducible mating. The Small-Form-Factor LC and MT-J-coupler enable an increase of density by 100% through interconnecting two fibers provided by the referring MT-J and LC-duplex connector. HDCS offers all industry standard fiber optic adapters, which can be used for fiber patch panel front interface or simple joint of two fiber optic connectors. Features and Benefit Comply with international standards Low coupling loss Singlemode or Multimode or both Metal or Plastic housing Bronze or Ceramic Alignment Sleeves Simplex or Duplex Flange-less or w/flange Hybrids ADAPTE & COUPLE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

40 Order Information HDCS 98E-01 98E-02 PN Description Sleeve Material Color LC/PC, MM duplex Ceramic Sleeve Beige LC/PC, SM duplex adapter Ceramic Sleeve Blue ADAPTE & COUPLE 98E-03 MT-J Standard Adapter Not Defined Black 98E-04 ST SM/MM simplex adapter, metal housing Ceramic Sleeve Metal 98E-05 ST MM simplex adapter, metal housing Phosphor Bronze Metal 98E-06 ST SM/MM duplex adapter, metal housing Ceramic Sleeve Metal 98E-07 ST MM duplex adapter, metal housing Phosphor Bronze Metal 98E-08 SC/PC MM simplex adapter Ceramic Sleeve Beige 98E-09 SC/PC SM simplex adapter Ceramic Sleeve Blue 98E-10 SC/PC MM duplex adapter, w/flange Ceramic Sleeve Beige 98E-11 SC/PC SM duplex adapter, w/flange Ceramic Sleeve Blue 98E-12 SC/ST SM/MM simplex adapter, metal, rectangular Ceramic Sleeve Metal 98E-13 SC/ST SM/MM adapter, metal housing with flange Ceramic Sleeve Metal 98E-14 FC/PC/APC SM/MM simplex adapter, D-D style Ceramic Sleeve Metal 98E-15 FC/PC/APC SM/MM simplex adapter, square Ceramic Sleeve Metal 98E-16 FC/SC (PC&APC) simplex adapter, square, metal Ceramic Sleeve Metal 98E-18 MPO/MPO adapter Not Defined Black 98E-22 FC/ST adapter, metal housing, rectangular flange Ceramic Sleeve Metal 98E-23 SC/PC SM simplex adapter, round flange Ceramic Sleeve Blue 98E-25 LC-MU aimplex adapter Ceramic Sleeve Blue/Brown 98E-31 LC/PC SM duplex adapter snap-latch fixing Ceramic Sleeve Blue 98E-33 MU-MU simplex adapter Ceramic Sleeve Brown 98E-34 MU-MU duplex adapter Ceramic Sleeve Brown 98E-35 MU-SC simplex adapter Ceramic Sleeve Brown 98E-36 SC SM/MM duplex adapter, metal housing Ceramic Sleeve Metal 98E-39 FC/APC simplex adapter, D-D, narrow key 2.03~2.08mm Ceramic Sleeve Metal 98E-40 SC/APC simplex adapter, green Ceramic Sleeve Green 98E-41 E2000 simplex singlemode PC adapter Ceramic Sleeve Blue 98E-42 E2000 simplex singlemode APC adapter Ceramic Sleeve Green 98E-43 SC/FC simplex adapter, rectangular flange Ceramic Sleeve Metal 98E-46 SC/PC, SM duplex adapter without flange Ceramic Sleeve Blue 98E-47 SC/PC, MM duplex adapter without flange Ceramic Sleeve Beige 98E-48 LC/PC, SM simplex adapter Ceramic Sleeve Blue 98E-49 LC/PC, MM simplex adapter Ceramic Sleeve Beige 98E-50 LC/PC, SM duplex adapter, hole fixing Ceramic Sleeve 98E-51 MT-J adapter with SC foot print Not Defined 98E-52 MT-J adapter with SC foot print Not Defined 98E-53 FC/PC SM/MM D-D style, 6-side flange Ceramic Sleeve 98E-54 E-2000/E-2000 SM duplex adapter H Ceramic Sleeve 98E-56 MU/MU, MM duplex adapter H Ceramic Sleeve Blue Black White Metal Blue Beige 98E-57 MU/MU, SM duplex adapter H 98E-59 SC/PC SM simplex adapter, without flange 98E-60 SC/PC MM simplex adapter, without flange 98E-62 Adapter FC/PC, D-shape, SM/MM 98E-65 SC/PC simplex adapter, SM/MM, metal Ceramic Sleeve Ceramic Sleeve Ceramic Sleeve Ceramic Sleeve Ceramic Sleeve Blue Blue Beige Metal Metal 40 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

41 7 Fiber-To-The-Desk Increasing bandwidth and security demands in Local Area Networks (LANs) lead to a shift form copper to fiber optic solutions. In future installations not only the campus and building backbone of a LAN is implemented in fiber optic but also Fiber-To-The-Desk (FTTD) with be a frequently requested solution. The term Fiber-To-The-Desk (FTTD) is used to describe the horizontal cabling in the areas of data transmissions and telecommunication, which leads from the floor distributor to the outlets at the workplace. In the standards ISO/IEC and EN50173 it is the tertiary level. osenberger HDCS offers such solutions for Fiber-To-The- Desk (FTTD) by providing field installable connectivity system and fiber optic outlets/aceplates. osenberger HDCS Crimp Fiber Optic Connectors osenberger HDCS crimp fiber optic connectors enable a FOTP-171 rapid and easy field termination. They are available for the standard connectivity systems ST, FC and SC, as well as for Small Form Factor connectors LC and MT-J. These connectors contain a pre-polished fiber stub. The result is a time saving crimping termination process requiring no polishing, no epoxying and power supply. Ordering Information HDCS Feature and Benefit A time consuming polishing process can be avoided The termination of the connector can be easily done with the fiber desk crimp tool without a power supply on site No interruption caused by gluing process Complete installation procedure can be done within a few minutes The successful termination requires the Fiber-To-The-Desk Toolkit Toolkit bag contains all necessary tools to terminate the connectors on all standard cable types with diameters of 0.9mm and 3.0mm Compliant with ANSI/TIA/EIA-568-B.3 IL: 0.4dB average for SM, FOTP-171 IL: 0.3dB average for MM, P/N Description Unit 98B02-55 Crimp Connector SC, 9/12um ea 98B02-56 Crimp Connector SC, 50/125um ea Fiber-To-The-Desk Fiber-To-The-Desk 98B02-57 Crimp ConnectorSC, 62.5/125um ea SC LC 98B01-57 Crimp ConnectorST, 9/125um ea 98B01-58 Crimp Connector ST, um ea 98B01-59 Crimp Connector ST, 62.5/125um ea FIBE-TO-THE-DESK 98B06-18 Crimp Connector MT-J, 9/125um, with pin 98B06-19 Crimp Connector MT-J, 50/125um, with pin 98B06-20 Crimp Connector MT-J, 62.5/125um, with pin ea ea ea Fiber-To-The-Desk ST Fiber-To-The-Desk Toolkit 98B04-27 Crimp Connector LC, 9/125um 98B04-28 Crimp Connector LC, 50/125um 98B04-29 Crimp Connector LC, 62.5/125um ea ea ea Fiber-To-The-Desk Crimp Tool 98B01-62 Crimp Connector ST, Laser optimized 50/125um 98B02-80 Crimp Connector SC, Laser optimized 50/125um 98B06-24 Crimp Connector MT-J, Laser optimized 50/125um 98B04-43 Crimp Connector LC, Laser optimized 50/125um ea ea ea ea osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

42 HDCS Fiber Optic Outlet FIBE-TO-THE-DESK osenberger HDCS fiber optic outlets are used to connect workplace computers with the horizontal fiber optic installation. Feature and Benefit Flexible installation four types of wall outlets are offered Connectivity system ST, SC-duplex, LC-duplex and MT-J are supported Fit with standard 86x86mm wall back box 45 degree angled outlet without coupler/keystone attached Fiber optic adapters or modules available Delivered with installation screws and labeling system Specification/Solution When J45 mountable angled faceplates are chosen, the following fiber optic keystone modules can be used for providing various fiber optic connections: LC-duplex singlemode keystone module (2/4 fibers) LC-duplex multimode keystone module (2/4 fibers) SC-simplex singlemode keystone module (2 fibers) SC-simplex multimode keystone module (2 fibers) ST-simplex keystone module (2 fibers) MT-J keystone modules (2/4 fibers) When fiber optic coupler direct-adapting type of angled faceplates are chosen, the following fiber optic couplers can be used for providing required fiber optic connections: SC-duplex singlemode coupler (2 fibers) SC-duplex multimode coupler (2 fibers) SC/ST-duplex coupler (2 fibers) ST-simplex coupler (2 fibers) Ordering Information HDCS P/N Description Pack Fiber optic coupler direct-adapting type CP FTTD Faceplate, SC-duplex Adapter Type, Ivory 12pcs/box CP FTTD Faceplate, 2xST-simplex Adapter Type, Ivory 12pcs/box 98E-11 SC/SC-Duplex Singlemode Adapter, Blue 100pcs/box 98E-10 SC/SC-Duplex Multimode Adapter, Beige 100pcs/box 98E-04 ST/ST-Simplex Adapter, Metal 100pcs/box 98E-13 SC/ST-Duplex Adapter, Metal 100pcs/box J45 mountable angled faceplate type CP Angled 1-port J Faceplate, Ivory 12pcs/box CP Angled 2-port J Faceplate, Ivory 12pcs/box CP MT-J Keystone Module 10pcs/box CP LC-Duplex Multimode Keystone Module 10pcs/box CP ST-Simplex Keystone Module 10pcs/box CP SC-Simplex Singlemode Keystone Module 10pcs/box CP SC-Simplex Multimode Keystone Module 10pcs/box CP LC-Duplex Singlemode Keystone Module 10pcs/box 42 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

43 8 Installation Tool & Accessory osenberger HDCS offers all necessary tools and accessories for on-site fiber optic connector polish termination and quick crimp termination. The tool can be ordered in a package HDCS On-Site Crimp Tool Kit osenberger HDCS on-site crimp tool kit is designed with the installer in mind with convenient package in an easy-tocarry ballistic nylon bag, and the tool kit is compact and easy to be carried around the work site. Ordering Information Item Description Q'ty HDCS PN Basic Tool Kit Tool Kit 1 Basic Installation Tool Kit 1 98K Installation Tool Kit with CTS 1 98K Connector Installation Critical Steps Card 1 of tool kit form or separately. The tool can be used to install SC, STII, FC, LC, MT-J fiber connectors on-site either by manual polishing or direct crimp termination. Feature and Benefit Convenient carrying bag Full and very detailed instructions included Compatible for terminating both singlemode and multimode SC, FC, STII, LC and MT-J connectors CTS (Continuity Test Set) option reduces scrap rate and helps train non-skilled installers All accessories for HDCS crimp connectors are provided in one kit 98K Connector Installation ecommended 4 Procedures Document 1 98K Connector Installation Video 1 98K Connector Strip Length Gauge Card 1 98K Connector Elite Installation Tool 1 98K Crimp Tool 1 98K Score and Snap Fiber Cleaver 1 98K Fiber Stripper, Miller 1 98K No-Nik Stripper 1 98K Jacket Stripper 1 98K Electrician's Scissors 1 98K Number Marker 1 98K Tweezers 1 98K Alcohol Wipes 6 98K Permanent Marker 1 98K Electrician's Tape 1 98K Loctite 411 Adhesive 1 98K Black Adhesive Anvil Strips 7 98K MSDS, 411 Adhesive 1 98K MSDS, Alcohol Wipes 1 98K Connector Continuity Test Set 1 98K Connector Standard Tool Bag 1 98K INSTALLATION TOOL & ACCESSOY osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

44 INSTALLATION TOOL & ACCESSOY HDCS On-Site Polish Tool Kit osenberger HDCS on-site polish tool kit is designed for installing the fiber optic connectors at work site by applying manual polishing. The SC, FC and STII connectors can be terminated on 900um or 2.0mm/3.0mm jacketed fiber cables by using this tool kit together with the osenberger HDCS consumable kit. Ordering Information Item Description Q'ty HDCS PN Tool Kit 1 HDCS On-Site Termination Tool Kit 1 98K Fiber Protector, ST 24 3 Fiber Protector, SC 24 4 Crimp Tool 1 5 PVC Electrical Tape Hand Microscope Kit 1 7 Fiber Scriber 1 8 Alcohol Bottle 2 9 Hand Polishing Jig 1 10 ubber Pad Feature and Benefit Complete termination set up with all tools except loss tester Full and very detailed operating instructions included Compatible for terminating both singlemode and multimode SC, FC, STII connectors Easy to carry with compact suitcase box 98K K K K K K K K K Curing Oven with Thermometer & Powercord 1 98K Jacket Stripper 1 98K Fiber Stripper 1 98K Aramid Yarn Scissor 1 98K Tool Kit Suitcase 1 98K Termination Instruction 1 98I osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

45 HDCS On-Site Polish Consumable Kit The consumable kit is used for on-site polishing connector installation on 900um buffered fibers or on 2.0mm/3.0mm jacketed fiber optic cables. It provides all necessary consumables sufficient for terminating at least 100 pieces of FC, SC, STII connectors. Ordering Information Item Description Q'ty 1 HDCS On-Site Termination Tool Kit 1 2 Polishing Film,15u, Brown, SC 5 3 Polishing Film, 3u, Pink, Diamond 5 4 Polishing Film, 1u, Brown, Diamond 5 5 Syringe, 5cc 3 6 Texwipe Tx EPO-TEK 353ND-4G 3 Feature and Benefit Polishing films, texwipes and epoxies included for on-site connector termination Material individually packed & labeled for easy identification Sufficient for at least 100 pieces of fiber optic connector termination Period of validity of epoxy is 1 year from D.O.M HDCS PN 98K K K K K K K10101 Tool Kit INSTALLATION TOOL & ACCESSOY osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

46 HDCS Copper Solutions osenberger HDCS LAN Cable 48 Keystone & Module 61 HDCS Outlet & Faceplate 66 Patch Panel 68 osenberger HDCS 110 System 70 LAN Jumper & Plug 72 Installation Tool & Accessory 77

47 HDCS Products & Solutions

48 9 osenberger HDCS LAN Cable HDCS LAN CABLE osenberger HDCS LAN cables are designed for structured premises/cabling system. osenberger provides integrated LAN cables from Class C to Class F solutions. CAT.3 CAT.5 CAT.5e CAT.6 CAT.7 CAT.6 UTP Data Cable Application CAT.6 LAN cable for structured premise cabling transmits voice, data and video signals. They support current highbandwidth applications, especially suitable to Class E Solution. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video T-16 Active and Passive 155 Mbit /622Mbit /1.2 Gbit ATM 10baseT/100baseT Fast /1000baseT Gigabit Ethernet Feature and Benefit osenberger indoor and outdoor CAT.6 UTP cables are designed for unshielded cabling system. osenberger HDCS CAT.6 cables exceed TIA/EIA-568-B.2-1 and ISO/IEC nd requirements for CAT.6 performance by significant margins on all parameters. It is available in different jacket material for various grades of anti-flame. Construction Construction: 4 2 AWG23 Conductor: AWG 23 solid copper Insulation: HDPE Core: 4 twist pairs Sheath: PVC, LSZH or PE Colour: Grey, Orange and Black Nominal Diameter: 6.3mm Conductor Insulation Twist pair PE filling ip cord Sheath Electrical Performance at 20 DC esistance 9.38 /100m Unbalanced resistance 5% Unbalance capacitance 330pF/100m Capacitance 5.6nF/100m Dielectric strength DC 1kv (3s No Fail) Insulation resistance 5000M Km Impedance (1-250MHZ) ( MHZ) Delay skew 45ns Mechanical Performance at 20 Bending adius During installation (min.) 8 outer diameter Installed (min.) 4 outer diameter Temperature ange During installation 0 to + 50 Installed -20 to osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

49 High-Frequency Performance at 20 Frequency (MHz) *At least 3dB NET headroom above CAT.6 Characteristic Graph Attenuation NET L PSNET ELFET PSELFET AC Propagation (db/100m) (db) (db) (db) (db) (db) (db) Delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. Max AC NET HDCS LAN CABLE Frequenoy (MHz) Frequenoy (MHz) Ordering Information Order Number CP CP CP CP CP CP CP CP CP CP Description CAT.6 indoor UTP cable, CM, 305m (eel in box) CAT.6 indoor UTP cable, LSZH, 305m (eel in box) CAT.6 indoor UTP cable, CM, 305m (eel in box) CAT.6 indoor UTP cable, CM, 305m (eel in box) CAT.6 indoor UTP cable, CMP, 305m (eel in box) CAT.6 indoor UTP cable, CM, 305m (Box) CAT.6 indoor UTP cable, CM, 305m (Box) CAT.6 indoor UTP cable, CM, 305m (Box) CAT.6 indoor UTP cable, CMP, 305m (Box) CAT.6 outdoor UTP cable, PE, 305m (eel) osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

50 CAT.6 FTP Data Cable HDCS LAN CABLE CAT.6 LAN cable for structured premise cabling transmits voice, data and video signals. They support current high-bandwidth applications, especially suitable to shielded Class E Solution. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video T-16 Active and Passive 155 Mbit/622Mbit/1.2 Gbit ATM 10baseT/100baseT Fast/1000baseT Gigabit Ethernet Feature and Benefit osenberger indoor and outdoor CAT.6 FTP cables are designed for shielded cabling system. osenberger HDCS CAT.6 cables exceed TIA/EIA-568-B.2-1 and ISO/IEC nd requirements for CAT.6 performance by significant margins on all parameters. It is available in different jacket material for various grades of anti-flame. Construction Construction: 4 2 AWG23 Conductor: AWG23 solid copper Insulation: HDPE Core: 4 twist pairs Foil: PET tape Screen: AL/PET tape Drain wire: AWG23 tinned copper Sheath: PVC, LSZH or PE Colour: Grey, Orange, and Black Nominal diameter: 7.4mm Electrical Performance at 20 DC esistance 9.38 /100m Unbalanced resistance 5% Capacitance 5.6nF/100m Dielectric strength DC 1kv, 3s No Fail Insulation resistance 5000M. Km Impedance Delay skew 45ns Conductor Insulation PET tape PE filling Drain AL foil screen ip cord Sheath 50 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

51 Mechanical Performance at 20 Bending adius During installation (min.) Installed (min.) During installation Installed High-Frequency Performance at 20 Frequency (MHz) Ordering Information Temperature ange 8 outer diameter 4 outer diameter 0 to to + 60 Attenuation NET L PSNET ELFET PSELFET AC (db/100m) (db) (db) (db) (db) (db) (db) Max. Max. Min. Min. Min. Min. Min Propagation Delay Max HDCS LAN CABLE Order Number CP CP CP CP CP CP Description CAT.6 outdoor FTP cable, PE, 305m CAT.6 indoor FTP cable, CM, 305m CAT.6 indoor FTP cable, LSZH, 305m CAT.6 indoor FTP cable, CM, 305m CAT.6 indoor FTP cable, CM, 305m CAT.6 indoor FTP cable, CMP, 305m osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

52 CAT.5e UTP Data Cable OSENBEGE HDCS LAN CABLE Application HDCS CAT.5e LAN cable for structured premise cabling transmits voice, data and video signals. They support current high-bandwidth applications, especially suitable to Class D Solution VoIP ISDN Token ring 100 Mbps TP-PMD 155 Mbit/622Mbit ATM Analog and digital video T-16 Active and Passive 10baseT/100baseT Fast Ethernet Electrical Performance at 20 DC esistance 9.38 /100m Unbalanced resistance 5% Unbalanced capacitance 330pF/100m Capacitance 5.4nF/100m Dielectric strength DC 1kv, 3s No Fail Insulation resistance 5000M. Km lmpedance (1-250MHz) Delay skew 45ns Construction Construction: 4 2 AWG24 Conductor: AWG 24 solid copper Insulation: HDPE Core: 4 twist pairs Screen: PVC, LSZH or PE Core: Grey, Orange and Black Nominal diameter: 5.1 mm Conductor Insulation Twist pair ip cord Sheath 52 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

53 Mechanical Performance at 20 During installation (min.) Installed (min.) During installation Installed High-Frequency Performance at 20 Frequency (MHz) *at least 6dB NET hesdroom above CAT.5e standard Ordering Information Order Number CP CP CP CP CP CP Bending adius Temperature ange Description 8 outer diameter 4 outer diameter 0 to to + 60 Attenuation NET L PSNET ELFET PSELFET AC Propagation (db/100m) (db) (db) (db) (db) (db) (db) Delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. Max N/A N/A N/A CAT.5e outdoor UTP cable, PE, 305m CAT.5e indoor UTP cable, CM, 305m CAT.5e indoor UTP cable, LSZH, 305m CAT.5e indoor UTP cable, CM, 305m CAT.5e indoor UTP cable, CM, 305m CAT.5e indoor UTP cable, CMP, 305m OSENBEGE HDCS LAN CABLE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

54 CAT.5e FTP/SFTP Data Cable OSENBEGE HDCS LAN CABLE Application HDCS CAT.5e LAN cable for structured premise cabling transmits voice, data and video signals. They support current high-bandwidth applications, especially suitable to shielded Class D Solution VoIP ISDN Token ring 100 Mbps TP-PMD 155 Mbit/622Mbit ATM Analog and digital video T-16 Active and Passive 10baseT/100baseT Fast Ethernet Electrical Performance at 20 DC esistance Mechanical Performance at 20 During installation (min.) Installed (min.) During installation Installed 9.38 /100m Unbalanced resistance 5% Unbalanced capacitance 330pF/100m Capacitance 5.4nF/100m Dielectric strength DC 1kv, 3s No Fail Insulation resistance 5000M. Km Impedance Delay skew 45ns Bending adius 8 outer diameter 4 outer diameter Temperature ange 0 to to + 60 Feature and Benefit osenberger indoor and outdoor CAT.5e FTP/SFTP cables are designed for shielded cabling system. Especially the SFTP cable screened with foil and copper braid provides excellent screen effect. osenberger HDCS CAT.5e cables exceed TIA/EIA-568-B.2 and ISO/IEC nd requirements for CAT. 5e performance by significant margins on all parameters and EMI performance. It is available in different jacket material for various grades of anti-flame. Construction Construction: 4 2 AWG24 Conductor: Insulation: AWG 24 solid copper HDPE Core: 4 twist pairs FTP screen: AL/PET tape STP screen: Braid screen + AL/PET tape Sheath: Colour: PVC, LSZH or PE Grey, Orange and Black Nominal Diameter: 6.6 /6.3mm Conductor Insulation PET tape AL foil screen Drain wire Braid screen ip cord Sheath 54 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

55 High-Frequency Performance at 20 Frequency Ordering Information Order Number Attenuation NET L PSNET ELFET PSELFET AC Propagation (MHz) (db/100m) (db) (db) (db) (db) (db) (db) Delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. Max N/A N/A N/A CP CP CP CP CP CP CP CP CP CP CP CP Description CAT.5e outdoor FTP cable, PE, 305m CAT.5e indoor FTP cable, CM, 305m CAT.5e indoor FTP cable, LSZH, 305m CAT.5e indoor FTP cable, CM, 305m CAT.5e indoor FTP cable, CM, 305m CAT.5e indoor FTP cable, CMP, 305m CAT.5e outdoor S/FTP cable, PE, 305m CAT.5e indoor S/FTP cable, CM, 305m CAT.5e indoor S/FTP cable, LSZH, 305m CAT.5e indoor S/FTP cable, CM, 305m CAT.5e indoor S/FTP cable, CM, 305m CAT.5e indoor S/FTP cable, CMP, 305m OSENBEGE HDCS LAN CABLE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

56 OSENBEGE HDCS LAN CABLE CAT.5e 25P UTP Data Cable Application osenberger HDCS CAT. 5e LAN cable for structured premise cabling transmits voice, data and video signals.they support current high-bandwidth applications, especially suitable to Class D Solution VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video Conductor 155 Mbit /622Mbit ATM Insulation T-16 Active and Passive Twist pair PET tape 10baseT/100base ip cord Sheath T Fast Ethernet High-Frequency Performance at 20 Frequency (MHz) Feature and Benefit osenberger CAT.5e 25P UTP cable is designed for highly integrated cabling system. osenberger HDCS CAT. 5e cables exceed TIA/EIA-568-B.2 and ISO/IEC nd requirements for CAT.5e performance by significant margins on all parameters. It is available in different jacket material for various grades of Anti-flame. Construction Conductor: AWG 24 solid copper Construction: 25 2 AWG24 Insulation: HDPE ip cord: Nylon Lay length: Different twist pair with different lay length Sheath: PVC, LSZH or PE Colour: Grey, Orange, And Black Attenuation NET L PSNET ELFET PSELFET AC Color Map Propagation (db/100m) (db) (db) (db) (db) (db) (db) Delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. Max. No Map No Map 1 Blue-White/Blue 14 Brown-Black/Brown 2 Orange-White/Orange 15 Grey-Black/Grey 3 Green-White/Green 16 Blue-Yellow/Blue 4 Brown-White/Brown 17 Orange-Yellow/Orange 5 Grey-White/Grey 18 Green-Yellow/Green 6 Blue-ed/Blue 19 Brown-Yellow/Brown 7 Orange-ed/Orange 20 Grey-Yellow/Grey 8 Green-ed/Green 21 Blue-Purple/Blue 9 Brown-ed/Brown 22 Orange-Purple/Orange 10 Grey-ed/Grey 23 Green-Purple/Green 11 Blue-Black/Blue 24 Brown-Purple/Brown 12 Orange-Black/Orange 25 Grey-Purple/Grey 13 Green-Black/Green Ordering Information Order Number CP CP CP CP CP CP CP CP CP CP Description CAT.5e indoor 25P UTP cable, CM, 305m CAT.5e indoor 25P UTP cable, LSZH, 305m CAT.5e indoor 25P UTP cable, CM, 305m CAT.5e indoor 25P UTP cable, CM, 305m CAT.5e indoor 25P UTP cable, CMP, 305m CAT.5e indoor 25P UTP cable, CM, 500m CAT.5e indoor 25P UTP cable, LSZH, 500m CAT.5e indoor 25P UTP cable, CM, 500m CAT.5e indoor 25P UTP cable, CM, 500m CAT.5e indoor 25P UTP cable, CMP, 500m 56 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

57 CAT.5 25P UTP Data Cable Application HDCS CAT.5 multipair LAN cable for structured premise cabling transmits voice, data and video signals. They support current high-bandwidth applications, especially suitable to Class C Solution ISDN Token ring 155 Mbit ATM 100 Mbps TP-PMD T-16 Active and Passive 10baseT/100baseT Fast Etherne High-Frequency Performance at 20 Frequency (MHz) Attenuation NET L PSNET Propagation (db/100m) (db) (db) (db) Delay (ns/100m) Max. Min. Min. Min. Max Ordering Information Order Number CP CP CP CP CP CP CP CP CP CP Conductor Insulation Twist pair PET tape ip cord Sheath Description CAT.5 indoor 25P UTP cable, CM, 305m CAT.5 indoor 25P UTP cable, LSZH, 305m CAT.5 indoor 25P UTP cable, CM, 305m CAT.5 indoor 25P UTP cable, CM, 305m CAT.5 indoor 25P UTP cable, CMP, 305m CAT.5 indoor 25P UTP cable, CM, 500m CAT.5 indoor 25P UTP cable, LSZH, 500m CAT.5 indoor 25P UTP cable, CM, 500m CAT.5 indoor 25P UTP cable, CM, 500m CAT.5 indoor 25P UTP cable, CMP, 500m Feature and Benefit osenberger CAT.5 multipair UTP cable is designed for highly integrated cabling system. osenberger HDCS CAT.5 cables meet or exceed TIA/EIA-568-B.2 Annex N and ISO/IEC nd requirements for CAT.5 performance by significant margins on all parameters. It is available in different jacket material for various grades of anti-flame. Construction Conductor: AWG 24 solid copper Construction: 25 2 AWG24 ip cord: Nylon Lay length: Different twist pair with different lay length OSENBEGE HDCS LAN CABLE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

58 OSENBEGE HDCS LAN CABLE CAT.3 Muiti-pair UTP Data Cable Application osenberger HDCS CAT.3 multipair LAN cable for structured premise cabling transmits voice and data signals. They are suitable to highly integrated applications. 10baseT Ethernet T-16 Active and Passive Feature and Benefit osenberger CAT.3 multipair UTP cable is designed for highly integrated cabling system. osenberger HDCS CAT.3 cables exceed TIA/EIA-568-B.2 and ISO/IEC nd requirements for CAT.3 performance by significant margins on all parameters. It is available in different jacket material for various grades of anti-flame. Ordering Information Order Number CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP Description CAT.3 indoor 25P UTP cable, CM, 305m CAT.3 indoor 25P UTP cable, LSZH, 305m CAT.3 indoor 25P UTP cable, CM, 305m CAT.3 indoor 25P UTP cable, CM, 305m CAT.3 indoor 25P UTP cable, CMP, 305m CAT.3 indoor 25P UTP cable, CM, 500m CAT.3 indoor 25P UTP cable, LSZH, 500m CAT.3 indoor 25P UTP cable, CM, 500m CAT.3 indoor 25P UTP cable, CM, 500m CAT.3 indoor 25P UTP cable, CMP, 500m CAT.3 indoor 50P UTP cable, CM, 305m CAT.3 indoor 50P UTP cable, LSZH, 305m CAT.3 indoor 50P UTP cable, CM, 305m CAT.3 indoor 50P UTP cable, CM, 305m CAT.3 indoor 50P UTP cable, CMP, 305m CAT.3 indoor 50P UTP cable, CM, 500m CAT.3 indoor 50P UTP cable, LSZH, 500m CAT.3 indoor 50P UTP cable, CM, 500m CAT.3 indoor 50P UTP cable, CM, 500m CAT.3 indoor 50P UTP cable, CMP, 500m CAT.3 indoor 100P UTP cable, CM, 305m CAT.3 indoor 100P UTP cable, LSZH, 305m CAT.3 indoor 100P UTP cable, CM, 305m CAT.3 indoor 100P UTP cable, CM, 305m CAT.3 indoor 100P UTP cable, CMP, 305m CAT.3 indoor 100P UTP cable, CM, 500m CAT.3 indoor 100P UTP cable, LSZH, 500m CAT.3 indoor 100P UTP cable, CM, 500m CAT.3 indoor 100P UTP cable, CM, 500m CAT.3 indoor 100P UTP cable, CMP, 500m Construction Conductor: AWG 24 solid copper Construction: 25 2 AGW AGW AGW24 ip cord: Nylon Lay length: Different twist pair with different lay length Conductor Insulation Twist pair PET tape ip cord Sheath 58 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

59 CAT.7 STP Data Cable Application osenberger HDCS CAT.7 LAN cable for structured premise cabling transmits voice, data and video signals. They support current high-bandwidth applications, especially suitable to Class F Solution. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video T-16 Active and Passive 155 Mbit/622Mbit/1.2 Gbit ATM 10baseT/100baseT Fast /1000baseT Gigabit Ethernet Conductor Insulation Individual al foil screen Drain wire Braid screen ip cord Sheath Feature and Benefit osenberger CAT.7 cables are designed for shielded cabling system. osenberger HDCS CAT.7 cables exceed ISO/ IEC nd and IEC requirements for CAT.7 performance by significant margins on all parameters tested up to 600MHz. Especially the STP screened structure provides excellent screen effect and magnificent EMI performance. Construction Construction: Conductor: Insulation : Core: Screen: Drain wire: Sheath: Colour: Nominal Diameter: OSENBEGE HDCS LAN CABLE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

60 HDCS LAN CABLE High-Frequency Performance at 20 Frequency (MHz) Characteristic Graph Electrical Performance at 20 DC esistance 19.8 /100m Unbalanced resistance 2% Unbalancedcapacitance Ordering Information 1600pF/km Screen attenuation 60dB (30-600MHz) Dielectric strength DC 1kv, 1min no fail Insulation resistance 5000M. Km Impedance Delay skew Attenuation NET L PSNET ELFET PSELFET AC Propagation (db/100m) (db) (db) (db) (db) (db) (db) Delay Max. Min. Min. Min. Min. Min. Min. Max PSNET Frequenoy (MHz) MHz) MHz) MHz) 25ns/100m (4-600MHz) Order Number CP CP Description CAT.7 STP indoor cable, 4P, LSZH, 305m CAT.7 STP indoor cable, 4P, PVC, 305m 60 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

61 10 Keystone & Module CAT.3 Keystone Jack Application osenberger HDCS CAT.3 keystone jacks are designed for telephone cabling system. It is a part of the HDCS Cabling System, applicable to all structure hardware designs of this series. It can be installed on faceplate or surface mounting box. They are available in J11 version for 10baseT Ethernet, 155Mbit ATM, T-16 Active and T-16 Passive applications. Feature and Benefit Use 110 tool or KONE tool to install Front contact with excellent flexibility & reliability Meets FCC part 68 standards Mechanical Performance Housing material: PC UL94V-0 Insert material: PBT 20%GF UL94V-0 PCB material: F-4 1.6mm (Thickness) Contact material: Phosphor bronze stamp PIN 0.35mm IDC contact material: Phosphor bronze 0.50mm thickness with silver or nickel plating Wire: AWG 22 ~ 24 Life (plug in /out): 750 times IDC life: 200 times Electrical Performance Voltage rating: 125 VAC MS Current rating: 1.5 AMP Contact resistance: 100Mohm MA Insulation resistance: 1000Mohm 500V DC Dielectric strength: 750V AC MS 60Hz 1MIN Unbalance capacitance: 330pF/100m KEYSTONE & MODULE 90 degree unshielded keystone Size: L31.0W22.6H23.5mm 180 degree unshielded keystone Size: L31.5xW16.0xH22.0mm Ordering Information Order Number CP CP CP CP CP CP CP CP CP Description CAT.3 unshielded standard 90 degree keystone jack, black CAT.3 unshielded standard 90 degree keystone jack, yellow CAT.3 unshielded standard 90 degree keystone jack, blue CAT.3 unshielded standard 90 degree keystone jack, ivory CAT.3 unshielded standard 90 degree keystone jack, red CAT.3 unshielded standard 90 degree keystone jack, green CAT.3 unshielded standard 90 degree keystone jack, white CAT.3 unshielded standard 180 degree keystone jack, black CAT.3 unshielded standard 180 degree keystone jack, ivory osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

62 CAT.5e Keystone Jack KEYSTONE & MODULE Application osenberger HDCS CAT.5e keystone jack is a part of the HDCS Cabling system, applicable to all structure hardware designs of this series. It can be installed on faceplate, surface mounting box and modular patch panels. It can support all application of CAT.5 and CAT.5e classes such as 10Base, Fast Ethernet, Gigabit Ethernet, 155ATM, 622ATM, and 1.2GATM. 180 degree UTP keystone standard type Size: L34.5 W16.3 H22.0mm Feature and Benefit HDCS keystone jack exceeds CAT.5e highest performance as its design goal. With HDCS CAT.5e jumper cables, the HDCS series fully exceed the provision in the CAT.5e standard (ISO/IEC/WG3 N568) and have performance reservation Outstanding performance including NET/FET, Power sum NET/FET and eturn Loss, which ensures high link performance Termination cap provides excellent strain relief, helps control cable bend radius and securely retains wires Uses 110 tool or KONE tool to install or tool-less keystone available Third party 3P certification (UL) for hardware performance Handsome product aspects Different choice available including UTP 180 degree, UTP 90 degree, FTP 180 degree and FTP 90 degree 180 degree UTP keystone mini-type Size: L31.5 W16.0 H22.0mm 90 degree UTP keystone standard type Size: L30.7 W19.0 H22.0mm 180 degree shielded keystone type Size: L44.0 W17.3 H23.8mm 90 degree shielded keystone type Size: L46.0 W21.5 H22.0mm Physical Specification Material Plastic: High impact flame retardant plastic, UL94V-0 rated Contact: Phosphor bronze C5210EH Contact plating: Gold plating 50u over nickel plating 50~100u Mechanical Plug insertion life: 750 cycle min Plug retention force: 30Lbs min IDC contactor: Accept AWG solid wires Temperature : -40 to osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

63 Electrical Performance Current rating: 1.5 AMP Insulation resistance: 500Mega ohms min Contact resistance: 20milli-ohms max Dielectric strength: 750V AC MS 60Hz 1MIN High Frequency Performance at 20 Frequency (MHz) Ordering Information Order Number CP Attenuation NET L PSNET ELFET Max. Min. Min. Min. Min. Min CP CP S CP S CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP (db/100m) (db) (db) (db) (db) Description CAT.5e shielded standard 90 degree keystone jack, ivory CAT.5e shielded standard 180 degree keystone jack, ivory CAT.5e unshielded standard 180 degree keystone jack, black, mini-type CAT.5e unshielded standard 180 degree keystone jack, ivory, mini-type CAT.5e unshielded tool-less 90 degree keystone jack, black CAT.5e unshielded tool-less 90 degree keystone jack, ivory CAT.5e unshielded standard 90 degree keystone jack, black CAT.5e unshielded standard 90 degree keystone jack, yellow CAT.5e unshielded standard 90 degree keystone jack, blue CAT.5e unshielded standard 90 degree keystone jack, ivory CAT.5e unshielded standard 90 degree keystone jack, red CAT.5e unshielded standard 90 degree keystone jack, green CAT.5e unshielded standard 90 degree keystone jack, white CAT.5e unshielded standard 180 degree keystone jack, black CAT.5e unshielded standard 180 degree keystone jack, yellow CAT.5e unshielded standard 180 degree keystone jack, blue CAT.5e unshielded standard 180 degree keystone jack, ivory CAT.5e unshielded standard 180 degree keystone jack, red CAT.5e unshielded standard 180 degree keystone jack, green CAT.5e unshielded standard 180 degree keystone jack, white PSELFET (db) KEYSTONE & MODULE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

64 CAT.6 Keystone Jack KEYSTONE & MODULE Application osenberger HDCS CAT.6 keystone jack is a part of the HDCS Cabling system, applicable to all structure hardware designs of this series. It can be installed on various faceplate, surface mounting box and modular panels. It can support all application of CAT.5, CAT.5e and CAT.6 classes including 10Base, Fast Ethernet, Gigabit Ethernet, 155ATM, 622ATM and1.2gatm. 180 degree UTP keystone standard type Size: L34.5 W16.3 H22.0mm Feature and Benefit HDCS keystone jack exceeds CAT.6 highest performance as its design goal. With HDCS CAT.6 jumper cables, the HDCS series fully exceed the provision in the CAT.6 standard (ISO/IEC/WG3 N568) and have performance reservation Outstanding performance including NET/FET, Power sum NET/FET and eturn Loss, which ensures high link performance Termination cap provides excellent strain relief, helps control cable bend radius and securely retains wires Uses 110 tool or KONE tool to install or tool-less keystone available Third party 3P certification (UL) for hardware performance. Handsome product aspects Different choice available including UTP 180 degree, UTP 90 degree, FTP 180 degree and FTP 90 degree 90 degree UTP keystone standard type Size: L30.7 W19.0 H22.0mm 180 degree shielded keystone type Size: L44.0 W17.3 H23.8mm 90 degree shielded keystone type Size: L46.0 W21.5 H22.0mm Physical Specification Material Plastic: High impact flame retardant plastic, UL94V-0 rated Contact: Phosphor bronze C5210EH Contact plating: Gold plating 50u over nickel plating 50~100u Mechanical Plug insertion life: 750 cycle min Plug retention force: 30Lbs min IDC contactor: Accept AWG solid wires IDC lift: 200 times min Temperature: -40 to osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

65 Electrical Performance Current rating: 1.5 AMP Insulation resistance: 500Mega ohms min Contact resistance: 20milli-ohms max Dielectric strength: 750V AC MS 60Hz 1MIN High Frequency Performance at 20 Frequency Attenuation NET L PSNET ELFET PSELFET (MHz) (db/100m) (db) (db) (db) (db) (db) Max. Min. Min. Min. Min. Min Ordering Information Order Number CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP Description CAT.6 unshielded tool-less 90 degree keystone jack, black CAT.6 unshielded tool-less 90 degree keystone jack, ivory CAT.6 shielded standard 180 degree keystone jack, ivory CAT.6 shielded standard 90 degree keystone jack, ivory CAT.6 unshielded standard 90 degree keystone jack, black CAT.6 unshielded standard 90 degree keystone jack, yellow CAT.6 unshielded standard 90 degree keystone jack, blue CAT.6 unshielded standard 90 degree keystone jack, ivory CAT.6 unshielded standard 90 degree keystone jack, red CAT.6 unshielded standard 90 degree keystone jack, green CAT.6 unshielded standard 90 degree keystone jack, white CAT.6 unshielded standard 180 degree keystone jack, black CAT.6 unshielded standard 180 degree keystone jack, yellow CAT.6 unshielded standard 180 degree keystone jack, blue CAT.6 unshielded standard 180 degree keystone jack, ivory CAT.6 unshielded standard 180 degree keystone jack, red CAT.6 unshielded standard 180 degree keystone jack, green CAT.6 unshielded standard 180 degree keystone jack, white KEYSTONE & MODULE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

66 11 HDCS Outlet & Faceplate HDCS OUTLET & FACEPLATE Application osenberger standard J45 outlets & faceplates are applicable to all HDCS keystone jacks, telephone and fiber optic modules. Single-port mat type Features and Benefit With stay of the arts designing, they are special for the solution based on 86x86 system. Various surface color matching different customer preference Applying separate architecture wrap up the installing screws, together with automatic dust cover and labeling system 1, 2, 4-port solution available for CAT.3, CAT.5e and CAT.6 keystone jack mounting Dual-port mat type Single-port light type Dual-port light type 66 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610)

67 4-port light type Single-port 45 degree angled type Dual-port 45 degree angled type 1/2-port surface mount box (with shutter) Physical Specification Installation: Suitable for standard 86 86mm style wall box Material: ABS plastic UV94 V-0 rated Storage temperature: -40 to 70 Ordering Information Order Number Description CP faceplate single port light type, white CP faceplate dual port light type, white CP faceplate four port light type, white CP faceplate single port mat type, ivory CP faceplate dual port mat type, ivory CP faceplate 45 degree single port for J type, ivory CP faceplate 45 degree dual port for J type, ivory CP faceplate 45 degree for fiber optic ST type, ivory CP faceplate 45 degree for fiber optic SC duplex type, ivory CP Surface Mount box single port with shutter door, ivory CP Surface Mount box dual port with shutter door, ivory CP Surface Mount box single port without shutter door, ivory CP Surface Mount box dual port without shutter door, ivory CP Surface Mount box four port without shutter door, ivory CP Surface Mount box six port without shutter door, ivory HDCS OUTLET & FACEPLATE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

68 PATCH PANEL 12 Patch Panel Application osenberger HDCS patch panels are designed for both unshielded and shielded cabling system with excellent performance and easy installation, compatible with all HDCS modules, meanwhile having extremely high flexibility, adaptability and maximally integrated designing. It is available in 12, 16, 24, 32 and 48 ports. CAT.5e & CAT.6 Unshielded Modular Path Panel Feature and Benefit HDCS patch panel exceeds relevant CAT.5e and CAT.6 highest performance as its design goal Outstanding performance including NET/FET, Power sum NET/FET and eturn Loss guaranteeing good link performance Delivered with plastic cable management bar, installation screws and labelling system Both modular type and IDC type available for different customer choice Unshielded or shielded solution CAT.5e & CAT.6 Shielded Modular Panel CAT.5e & CAT.6 Unshielded IDC Patch Panel Physical Specification Material Front pane: Steel, powder coating Plastic: High impact flame retardant plastic, UL94V-0 rated Contact: Phosphor bronze C5210EH Contact plating: Gold plating 50u over nickel plating 50~100u Electrical Performance Current rating: 1.5 AMP Insulation resistance: 500Mega ohms min Contact resistance: 20milli-ohms max Dielectric strength: 750V AC MS 60Hz 1MIN CAT.5e & CAT.6 Shielded IDC Panel Mechanical Plug insertion life: 750 cycle min Plug retension force: 30Lbs min IDC contactor: Accept AWG solid wires IDC life: 200 times min. Temperature: -40 to osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610)

69 Physical Specification Panel frame: Steel, t=1.3mm Surface: Powder coating70~120u. Color: Standard black. Ordering Information HDCS P/N CP CP Description CAT.5e 24P Unshielded IDC patch panel, black CAT.5e 48P Unshielded IDC patch panel, black 19 1U metal management PATCH PANEL CP CAT.5e 24P Unshielded modular patch panel, black CP CP CP CAT.5e 48P Unshielded modular patch panel, black CAT.5e 16P shielded IDC patch panel, black CAT.5e 24P shielded IDC patch panel, black CP CP CAT.5e 16P shielded modular patch panel, black CAT.5e 24P shielded modular patch panel, black CP CAT.5e 48P shielded modular patch panel, black CP CP CAT.6 24P Unshielded IDC patch panel, black CAT.6 48P Unshielded IDC patch panel, black CP CP CP CP CP CAT.6 24P Unshielded modular patch panel, black CAT.6 48P Unshielded modular patch panel, black CAT.6 16P shielded IDC patch panel, black CAT.6 24P shielded IDC patch panel, black CAT.6 16P shielded modular patch panel, black CP CP CAT.6 24P shielded modular patch panel, black CAT.6 48P shielded modular patch panel, black CP CP CP HU Cable Management Panel, Metal, black Blank cover for modular panel port, black Blank cover for modular panel port, white osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610)

70 13 osenberger HDCS 110 System HDCS 110 SYSTEM Application 10baseT Ethernet 100baseT Fast Ethernet 155Mbit ATM 622Mbit ATM T-16 Active T-16 Passive Can freely connect with any kinds of 1, 2, 4, 5-pair standard modules Can accept 22~26AWG core wires Feature and Benefit HDCS 110 interconnect system is designed for unshielded premise cabling system with excellent performance and easy installation, compatible with all HDCS 110 blocks, meanwhile having extremely high flexibility, adaptability and maximally integrated designing for voice solution. It is available in wall mounted and rack versions. Connecting terminals on cables in modularized unit design, used to connect cables between horizontal cabling and telecommunication closet and only need to add module units. For expansion instead of replacing with a bigger one, 1, 2, 4, 5-pair jumpers are provided for flexible combination. HDCS provides several flexible specifications for 19 standard rack mounting and the other is 20cm hanging type to facilitate fixation on walls (the hanging type is further divided the two type of with foot rest and without foot rest). Specification Electrical and Mechanical Performance Contact resistance: 100Mohm Life (plug in /out) : 750 times Unbalance capacitance: 330pF/100m IDC life : 200 times Dielectric strength: AC 1KV, 1 Min. no Fail Gold plating thickness: 50u Electrical Performance at 20 Frequency (MHz) Attenuation NET L PSNET ELFET (db/100m) (db) (db) (db) (db) Max. Min. Min. Min. Min PSELFET (db) Min. 70 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

71 Ording Information Part Number CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP Description 110 jump block 50pairs, 1HU, rack 110 jump block 100pairs, 1HU, rack 110 jump block 200pairs, 2HU, rack 110 jump block 300pairs, 3HU, rack 110 jump block 50pairs, with leg, wall mount 110 jump block 100pairs, with leg, wall mount 110 jump block 200pairs, with leg, wall mount 110 jump block 300pairs, with leg, wall mount 110 jump block 50pairs, without leg, wall mount 110 jump block 100pairs, without leg, wall mount 110 jump block 200pairs, without leg, wall mount 110 jump block 300pairs, without leg, wall mount 110 jump block 4pairs connector 110 jump block 5pairs connector 110 jump block 1pair plug 110 jump block 2pairs plug 110 jump block 4paris plug 110 jump block 5pairs plug Wire management Panel, 1U, plastic HDCS 110 SYSTEM osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610)

72 LAN JUMPE & PLUG 14 LAN Jumper & Plug CAT.6 Patch Cord Application osenberger HDCS CAT.6 LAN cable assemblies for structured premise cabling transmit voice, data and video signals. They support current high-bandwidth applications, especially suitable to Class E Solution. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video T-16 Active and Passive 155 Mbit /622Mbit /1.2 Gbit ATM 10baseT/100baseT Fast /1000baseT Gigabit Ethernet Feature and Benefit osenberger CAT.6 patch cord is designed for unshielded and shielded cabling system with excellent performance and easy installation, meanwhile having extremely high flexibility, adaptability and maximal integrated designing. They exceed TIA/EIA-568B-2.1 CAT.6 requirements, together with unshielded and shielded version for Class E solution. It is available in PVC and LSZH jacket. Construction Multi-conductor inter-twisted soft copper wire shielded/unshielded plug with plastic injected plastic boot. Jacket material can be of PVC or LSZH High-Frequency Performance at 20 Frequency (MHz) NET(dB) 2m Cord 5m Cord 10m Cord L (db) osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

73 Ording Information Order Number Description CP CAT.6 unshielded Patch cord, 1M, PVC, grey CP CAT.6 unshielded Patch cord, 2M, PVC, grey CP CAT.6 unshielded Patch cord, 5M, PVC, grey CP CAT.6 unshielded Patch cord, 10M, PVC, grey CP CAT.6 shielded Patch cord, 1M, PVC, grey CP CAT.6 shielded Patch cord, 2M, PVC, grey CP CAT.6 shielded Patch cord, 5M, PVC, grey CP CAT.6 shielded Patch cord, 10M, PVC, grey CP CAT.6 unshielded Patch cord, 1M, LSZH, orange CP CAT.6 unshielded Patch cord, 2M, LSZH, orange CP CAT.6 unshielded Patch cord, 5M, LSZH, orange CP CAT.6 shielded Patch cord,1m, LSZH, orange CP CAT.6 shielded Patch cord, 2M, LSZH, orange CP CAT.6 shielded Patch cord, 5M, LSZH, orange CP C CAT.6 shielded Patch cord, 8M, LSZH, orange PN code: CPxx-xxn-xm n: (color) 1=grey, 2=yellow, 3=blue, 4=orange, 5=red, 6=green, 7=white m: (length) 1= 1m, 2=2m, 3=3m, 4=4m, 5=5m, 7=10m, 8=15, C=8m *For more information please contact the regional sales representative. Characteristic Graph NET L LAN JUMPE & PLUG Frequenoy (MHz) Frequenoy (MHz) osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

74 LAN JUMPE & PLUG CAT.5e Patch Cord Application osenberger HDCS CAT.5e LAN cable assemblies for structured premises cabling transmit voice, data and video signals. They support current high-bandwidth applications, especially suitable to Class D Solution. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video T-16 Active and Passive 155 Mbit /622Mbit ATM 10baseT/100baseT Fast Ethernet High-Frequency Performance at 20 Frequency (MHz) NET(dB) 2m Cord 5m Cord 10m Cord L (db) Ording Information Feature and Benefit osenberger CAT.5e patch cord is designed for unshielded and shielded cabling system with excellent performance and easy installation, meanwhile having extremely high flexibility, adaptability and maximal integrated designing. They exceed TIA/EIA-568B-2 CAT.5e requirements, together with unshielded and shielded version for Class D solution. It is available in PVC and LSZH jacket. Construction Multi-conductor inter-twisted soft copper wire Shielded/Unshielded plug with plastic injected Plastic boot. Jacket material can be of PVC or LSZH Order Number CP CP CP CP CP CP CP CP CP CP CP CP CP CP CP C Description CAT.5e unshielded Patch cord, 1M, PVC, grey CAT.5e unshielded Patch cord, 2M, PVC, grey CAT.5e unshielded Patch cord, 5M, PVC, grey CAT.5e unshielded Patch cord, 10M, PVC, grey CAT.5e shielded Patch cord, 1M, PVC, grey CAT.5e shielded Patch cord, 2M, PVC, grey CAT.5e shielded Patch cord, 5M, PVC, grey CAT.5e shielded Patch cord, 10M, PVC, grey CAT.5e unshielded Patch cord, 1M, LSZH, orange CAT.5e unshielded Patch cord, 2M, LSZH, orange CAT.5e unshielded Patch cord, 5M, LSZH, orange CAT.5e shielded Patch cord, 1M, LSZH, orange CAT.5e shielded Patch cord, 2M, LSZH, orange CAT.5e shielded Patch cord, 5M, LSZH, orange CAT.5e shielded Patch cord, 8M, LSZH, orange PN code: CPxx-xxn-xm n: (color) 1=grey, 2=yellow, 3=blue, 4=orange, 5=red, 6=green, 7=white m: (length) 1= 1m, 2=2m, 3=3m, 4=4m, 5=5m, 7=10m, 8=15, C=8m *For more information please contact the regional sales representative. 74 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

75 J45/110 and 110/110 Patch Cord Application 10baseT Ethernet 100baseT Fast Ethernet 155Mbit ATM 622Mbit ATM T-16 Active T-16 Passive Feature and Benefit osenberger HDCS J45 to 110 and 110 to 110 CAT5e Patch Cord is designed for unshielded cabling system with excellent performance and easy installation, meanwhile having extremely high flexibility, adaptability and maximally integrated designing. They exceed TIA/EIA-568B-2 CAT.5e requirements, together with J and version for Class D2002 solution. It is available in PVC and LSZH jacket. LAN JUMPE & PLUG Ording Information Order Number CP CP CP CP CP CP CP CP CP CP Description CAT.5e 1pair J45/110 unshielded, PVC, 1m, grey CAT.5e 1pair J45/110 unshielded, LSZH, 1m, orange CAT.5e 2pairs J45/110 unshielded, PVC, 1m, grey CAT.5e 2pairs J45/110 unshielded, LSZH, 1m, orange CAT.5e 4pairs J45/110 unshielded, PVC, 1m, grey CAT.5e 2pairs 110/110 unshielded, PVC, 1m, grey CAT.5e 2pairs 110/110 unshielded, LSZH, 1m, orange CAT.5e 1pair 110/110 unshielded, PVC, 1m, grey CAT.5e 1pair 110/110 unshielded, LSZH, 1m, orange CAT.5e 4pair 110/110 unshielded, PVC, 5m, grey PN code: CPxx-hxn-xm h: (pair) 1=1 pair, 2=2 pair, 3=4 pair-568a, 4=4 pair-568b, 5=4 pair n: (color) 1=grey, 2=yellow, 3=blue, 4=orange, 5=red, 6=green, 7=white m: (length) 1=1m, 2=2m, 3=3m, 4=4m, 5=5m, 7=10m, 8=15, C=8m *For more information please contact the regional sales representative. osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610)

76 Crystal Plug LAN JUMPE & PLUG Application osenberger HDCS CAT.6, CAT.5e and CAT.3 crystal plugs are designed for shielded and unshielded cabling system application. They are available in J45 and J11 versions. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video T-16 Active and Passive 155 Mbit/622Mbit/1.2 Gbit ATM 10baseT/100baseT Fast/1000baseT Gigabit Ethernet Electrical Performance Voltage rating: 125 VAC MS Current rating: 1.5 AMP Contact resistance: 100Mohm MA Insulation resistance: 1000Mohm 500V DC Dielectric strength: 750V AC MS 60Hz 1MIN Mechanical Performance Housing material: PC UL94V-0 Contact material : Phosphor bronze stamp PIN 0.35mm Wire: AWG22~24 Life (plug in/out): 750 times CAT.3 universal J11/J11 Ording Information Order Number CP CP CP CP CP CP Description CAT.5e unshielded plug J45 CAT.5e shielded plug J45 CAT.6 unshielded plug J45 CAT.6 shielded plug J45 CAT.3 unshielded plug J45 CAT.3 universal J11/J11 76 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

77 15 Installation Tool & Accessory Application Feature and Benefit Terminating HDCS keystone jacks with Palm Puck to provide safe protection and quick solution. 110 Type Insertion Tool applicable to all HDCS CAT.3, CAT.5e, CAT.6 keystone jacks and 110 block modules. IDC 4&5-Pair Punch Tool is used for terminating 4-pair 110 block modules or 5-pair 110 block modules. HDCS otary Cable Stripper provides perfect strip performance on HDCS CAT.5, CAT.5e and CAT.6 UTP as well as FTP/SFTP copper LAN cables different cable sizes Ording information Part Number Description CP HDCS Palm Puck CP HDCS 110-type Insertion Tool CP HDCS Insertion Tool (Krone Type) CP HDCS IDC 4&5-Pair Punch Tool CP HDCS otary Copper Cable Stripper HDCS 110-type Insertion Tool is according to the standard of the flesh engineering, and easily installed and locked up the knife-blade. The knife-blade is able to be concealed in the bottom of tool, and keeps from being damaged or abrased HDCS Palm Puck provides best protection against jack damage or injury Pre-setup of the strip size, while blade adjustable for INSTALLATION TOOL & ACCESSOY osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610)

78 FlexField Solutions FlexField Module 81 FlexField Subrack 84 FlexField Accessory 85

79 HDCS Products & Solutions

80 FlexField CONCEPT/FEATUE FlexField Concept/Feature FlexField is the most flexible and modular connection system. It handles coaxial, pair and fiber optic cables. It meets telecom standard G.703 and handles data - Ethernet CAT.6. The FlexField is built on modules and fits small as well as big systems. - Variety of Cable and Connector The FlexField consists of a number of various modules that can handle a variety of cables and connectors. - Mix of Module The FlexField is modular and incremental in its design. Different types of modules-for different connectors/cables can be in the same subrack, start with the number of modules you need for the moment, just partly fill the subrack. Add modules as the need grows. - Access to All Connector Due to the patented cable management there is always easy front access to all connections. The cable management creates a built in cable slack that allows the module to be extracted a minimum of 30cm from it s original position, even at full installation. - Safe Maintenance/Quick Access No stress on the connectors when moving the modules, the cables are mechanically fixed to the modules and ETSI acks/cabinet The subracks have adjustable mounting ears to fit both 19" and ETSI racks/cabinets. - Well Protected Patch Cord Patch cords are strictly managed and well protected. The patch cords from each module enter through their own slot into the cable shelf. The cable shelf has afoldable front allowing for quick access. 80 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

81 16 FlexField Module DDF G.703 Pair Cable & Coax + Balun Feature and Benefit - Transmission equirement-sw All signals pass through multi-layer impedance controlled PCBs and connectors of correct impedance. This gives good signal integrity and the transmission requirements in G.703 are met. The SW budget of your link will not be ruined by flex modules. Ording Information - EMC All PCBs have signals at the inner layer and shielding at the outer layers. This result in low emission and high immunity. The possibility for you to have your system to fulfill EMC-Standards like directives 89/336/EEC, 92/231/EEC will not be affected. - Surge Pulse In some telecom applications there is a 500V surge pulse requirement. They are tested according to IEC Module Type Front Inside Channel Capacity Part Number J-IDC J45 IDC E1/T1/J1 8 system J-J J45 J45 E1/T1/J 8 system IDC-IDC IDC IDC E1/T1/J 8 system J-J monitor J45 J45 E1/T1/J 4 system with J-IDC monitor J45 IDC, 8pair E1/T1/J 4 system with / / / /5.6 E1/T1/J1/E3/T3/J3/STM-1/Video 4 system / / / /5.6 E1/T1/J1/STM-1/Video 2 system with M4-M4 M4 M4 E1/T1/J1/E3/T3/J3/STM-1 4 system M4-M4 monitor M4 M4 E1/T1/J1/STM-1 2 system with BNC-BNC BNC BNC E1/T1/J1/E3/T3/J3/STM-1/Video 4 system BNC-BNC monitor BNC BNC E1/T1/J1/E3/T3/J3/STM-1/Video 3 system with SMB-SMB SMB SMB E1/T1/J1/E3/T3/J3 4 system SMB-SMB monitor SMB SMB E1/T1/J1/E3/T3/J3 2 system with /5.6-IDC balun 1.6/5.6 IDC, 8pair E1/T1/J1 4 system or 8 half M4-IDC balun M4 IDC, 8pair E1/T1/J1 4 system or 8 half BNC-IDC balun BNC IDC, 8pair E1/T1/J1 4 system or 8 half J-M4 balun J45 M4 E1/T1/J1 4 system J-BNC J45 BNC E1/T1/J1 4 system J-1.6/5.6 balun J45 1.6/5.6 E1/T1/J1 4 system Monitor cable J45 BNC For BS , BS / /5.6 monitor 1.6/ /5.6 E1/T1/J1/E3/T3/J3/STM-1 4 system with M4-M4 monitor M4 M4 E1/T1/J1/E3/T3/J3/STM-1 4 system with M4-IDC balun monitor M4 IDC E1/T1/J1 4 system /5.6-IDC balun monitor 1.6/5.6 IDC E1/T1/J1 4 system BNC-J BNC J45 E1/T1/J1 4 system FlexField CONCEPT/FEATUE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

82 FlexField CONCEPT/FEATUE Ethhernet Cabling System Feature and Benefit - The Patch Panel High density: up to 800 systems in a standard rack. Yet service friendly: the patch cords are strictly organized and all connections will be accessible. So cross connection work can be performed. Choose between modules for CAT.5e or CAT.6, STP or UTP. - The Work Area Outlet 8 J45 for 1-4 workplaces. Choose between modules for CAT.5e or CAT.6, STP or UTP. Ordering Information Module Type J-IDC Ethernet UTP CAT.5e J-IDC Ethernet STP CAT.6 with DC-Barrier J-J Ethernet STP/UTP CAT.5e Front J45 J45 J45 Channel IDC IDC J45 Inside - EMC ALL PCBs have signals at the inner and shielding at the outer layers. The cable shields are terminated at low impedance, which results in low emission and high immunity. The possibility for you to have your system to fulfill EMC-Standards like directives 89/336/EEC, 92/231/EEC will not be affected. - DC-Current in Cable Shield In an STP cabling there is always a risk for unwanted DCcurrent in the Shield due to varying ground potentials in the building. It causes a current to flow in the cable shields and it may give lower capacity in your network. To avoid it there is a module with built in DC-barrier. Ethernet 10/100UTP Ethernet 10/100/100+STP Ethernet 10/100STP/UTP Capacity 8 system 4 system 8 system Part Number J-IDC Ethernet UTP CAT.3 J45 IDC Ethernet CAT.3 UTP 10 system J-IDC Ethernet UTP CAT.6 J45 IDC Ethernet 10/100/100+UTP 6 system J-IDC Ethernet STP CAT.6 J45 IDC Ethernet 10/100/100+STP 6 system osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

83 ODF & Trunk Network + FTT Feature and Benefit - Variety of Application The modules handle 12 fibers each. They go into various size subracks. Thus, a wall mounted 12 fiber outlet can be built and also an ODF handles many hundreds of fibers. An ODF for the trunk network can be built. An ODF for fiber to the, can also be built. All have in common: service friendly, always access to all connectors and splices. - Variety of Cable Patch cords and breakout cables are terminated directly in the module. Installation cables-cables with unprotected fibers have to be installed in a cable splitter before entering the module. In the cable splitter the cable is mechanically fixed and the length of 2m of each fiber is put in a protective flexible tube (12 fibers per tube). Ordering Information Module Type Breakout SC-SC Splicing SC-SC Splicing SC-SC Description 2-12 Fibers Single mode breakout cable For splicing, fan out and pretermination of 12 fibers single mode adaptors For splicing of ribbon fiber or single fiber - Flexibility of Cable This tube enters the module. Splicing and fan-out of ribbon is done in the module. The excess length of the tube is stocked in a special storage compartment within the subrack. By using this excess of the tube each module can be extracted 1.5m from the subrack, thus allowing for splicing work conveniently done at worktable. Blown fiber can also be handled. The microducts are terminated to an adaptor. This adaptor fits into existing holes in the subrack. The flexible tubes are inserted in the free end of the adaptors. The fiber is blown in. The white tubes with fibers are handled in the modules as described above. Channel Capacity Part Number (0~6) 2 SC G-01 (0~6) 2 SC (0~6) 2 SC G-01 FlexField CONCEPT/FEATUE FC-FC For cables without splices and having low bending radius being able to be brought directly into the module: break out cable; patch cord cable FC/PC adaptors of SM quality, osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

84 FlexField CONCEPT/FEATUE 17 FlexField Subrack The modules go into subtracts. Subracks are available in different sizes. Different types of modules can be in the same subrack. Start with the number of modules you need for the moment, just partly fill the subrack. Add further modules whenever the need arises. Ordering Information Subrack 200 Subrack 45 Wall Mount Box Types Module Density Width Depth Height Part Number Subrack /ETS 270mm 200mm/5U Subrack mm 45mm/1U Wall Mount Box 1 130mm 190mm 45mm osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

85 18 FlexField Accessory The FlexField accessories are storage to manage and protect the cords. Storage Shelf Storage Bobbin Joint 48 Ordering Information Module Type Description Capacity Part Number Storage Shelf Storage of excess patch cord Occupies the space of two modules in the subrack Width: 80mm 5m each of 12 single patch cord or 6 double can be stored Storage of excess patch cord 5m each of 12 single patch cord or 6 Storage Bobbin Occupies the space of one module in the doublecan be stored subrack Joint 48 For joining a cable maximum 48 fibres to maximum 4 Modules FlexField CONCEPT/FEATUE osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

86 HDCS GLOSSAY-PEMISE CABLING 1000BASE-T 100BASE-T 10BASE2 10BASE5 10BASE-T 110 Connector 66 Block Adapter APC Aramid Yarn ATM Attenuation Backboard Backbone Cabling Bandwidth Balun Bend adius BE BNC Buffering CAT.3 CAT.5 CAT.5e CAT.6 Channel HDCS Glossary - Premise Cabling A recent LAN standard for implementing 1000Mbps Ethernet on CAT.5 and CAT.5e cables The twisted pair version of 100Mbps ethernet Also called Thinnet.10Mbps ethernet on thin (G58) coaxial cable Also called Thicknet.10Mbps ethernet on thick coaxial cable 10Mbps ethernet on twisted-pair (CAT.3) cable A popular insulation displacement connector (IDC) used modular jacks, patch panels and cross connects A legacy cross-connected system A mechanical media termination device designed to align and join fiber optic connectors Angled polish connector Strength elements that provide tensile strength and provide support and additional protection for the fiber bundles Asynchronous transfer mode The amount of signal lost as it travels through the cabling system. Both for copper and Optical fiber system efers to a plywood panel mounted on the wall of a telecom closet. Used to mount the cross connect Cabling between floors in a building or between buildings in a campus Measure of the information-carrying capacity of a copper or optical fiber cable A transformer used to attach coaxial or twinaxial equipment to twisted pair cabling The minimum recommended bending radius during installation of after installation where cable damage will not occur Cable bend radius during installation infers that the cable is experiencing a tensile load. Free bend infers a smaller allowable bend radius since it is at a condition of minimal load Bit Error ate A bayonet style coaxial connector A protective material extruded directly on the fiber A performance classification for twisted pair cables, connectors and systems. Specified to 16MHz. Suitable for voice and data applications up to 10Mbps A performance classification for twisted pair cables, connectors and systems. Specified to 100MHz Also called Enhanced CAT.5. A performance classification for twisted pair cables, connectors and systems. Specified to 100MHz A performance classification for twisted pair cables, connectors and systems. Specified up to 250MHz. Suitable for voice and data applications up to 1000Mbps The entire horizontal cabling system. Everything between the computer and the LAN hub in the telecom closet, excluding the equipment connections 86 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

87 Cladding The material surrounding the core of an optical waveguide. The cladding must have a lower index of refraction to keep the light in core Coating Coax Conduit Connector SFF Consolidation Point Core Coupling Data ate db Delay Skew Dispersion ELFET EMI Enhanced CAT.5 ESCON Ethernet F Connector Ferrule FET Fiber Optics Gbps Gigabit Ethernet Gigahertz Horizontal Cabling Hub IDC A material put on a fiber during the drawing process to protect it from the environment and handling Short for coaxial. Single-conductor cables with braided shields. Used in the 80's for data transmission. Now generally replaced with UTP for data. Still used for video Pipe or tubing through which cables can be pulled of housed A mechanical device used to align and join two fibers together to provide a means for attaching to and decoupling from a transmitter, receiver of another fiber Small form factor using for optical fiber solution An interconnect device that allows the horizontal cable to be split into two parts. Used for zone cabling The central region of an optical fiber through which light is transmitted See adapter The speed, measured in bits per second, that a particular network (or other application) transmits data Abbreviation for decibel. The logarithmic ratio of two powers, voltages or currents The difference in propagation delay between the slowest and fastest pairs in a cable or system The cause of bandwidth limitations in a fiber. Dispersion causes a broadening of input pulses along the length of the fiber. Three major types are: 1. modal dispersion. 2. chromatic dispersion. 3. waveguide dispersion Equal level far end crosstalk. A measure of FET, which accounts for the attenuation of the cabling system Electromagnetic Interference Also called CAT.5e.A performance classification for twisted pair cables, connectors and systems. Specified to 100MHz. Enterprise Systems Connection The most common network protocol in use. A protocol is a set of rules enabling data communications. Based originally on a bus topology A common coaxial connector used for video applications (CATV) A mechanical fixture, generally a rigid tube, used to protect and align a fiber in a connector. Generally associated with fiber optic connectors Far End Crosstalk. Unwanted noise coupled onto a receive pair from a transmit pair at the far end of the system Light transmission through optical fibers for communication or signaling A data rate. Gigabits per second. A gigabit is one billion bits The newest (1999) and fastest version of Ethernet. Data rate is 1000Mbps or 1 Gigabit per second A unit of frequency that is equal to one billion cycles per second, GHz That portion of the telecommunications cabling that provides connectivity between the horizontal cross-connect and work-area telecommunications outlet Network device, usually in the telecom closet, that stations connect to Insulation Displacement Connector. A style of connector that slices through the cable insulation to make a connection. Eliminates the need to strip insulation HDCS GLOSSAY-PEMISE CABLING osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

88 HDCS GLOSSAY-PEMISE CABLING IEEE Impedance Index of efraction Index Matching Fluid Jumper Kbps LAN Laser LED Link Loose Tube Cable LSZH Mbps Mechanical Splicing MHz Mode Modular Jack Modular Plug MT-J Multimode NET NIC Node Numerical Aperture (NA) OFCP OFC OFNP OFN OTD Outlet Patch Cord Patch Panel PB PC Institute of Electrical and Electronics Engineers The total opposition to the flow of alternating current in a conductor The ratio of light velocity in vacuum to its velocity in a given transmission medium A fluid with an index of refraction close to that of glass that reduces Fresnel reflections caused by refractiveindex differences Usually short cables with connectors installed used to make a cross connection A data rate. Kilobits, or thousands of bits, per second Local Area Network Light Amplification by Stimulated Emission of adiation Light Emitting Diode The part of the horizontal cabling system between the work area outlet and the telecom closet termination Type of cable design whereby coated fibers are encased in buffer tubes offering excellent fiber protection and segregation Low Smoke Zero Halogen A data rate. Megabits, or millions of bits, per second Joining two fibers together by permanent or temporary mechanical means to enable a continuous signal Megahertz. Millions of cycles (Hertz) per second. A frequency or frequency range (bandwidth) through which a Mode. A ter used to describe an independent light path through a fiber, as in multimode of single mode The standard female connector for twisted pair cable. A" telephone jack" The standard male connector for twisted pair cable. A" telephone plug" Mechanical Transfer-egistered Jack An optical waveguide in which light travels in multiple mode. Typical core/cladding size is 50/125 um Near end crosstalk. The unwanted noise coupled into a device s receive circuit from its transmit circuit Network interface card A device connected to a network The number that expresses the light-gathering ability of a fiber Optical fiber conductive plenum Optical fiber conductive riser Optical fiber nonconductive plenum Optical fiber nonconductive riser Optical time domain reflectometer Where the horizontal cabling terminates in the work area A cable assembly with (usually) a plug on each end, used to make a cross connection A collection of connector panels located in a common housing Private branch exchange Physical Contact. contact 88 osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

89 Pigtail Plenum Power sum Propagation Delay Propagation Delay Skew PS ELFET PS NET Punch Down ack eceiver epeater eturn Loss iser J11 J45 SC Connector Single Mode Splicing ST Connector STP STS Transmitter Thicknet Thinnet Token ing Twisted Pair Cable UL UTP VCSEL Wavelength Zero-Dispersion Wavelength Optical fiber cable that has a connector installed on one end An air-handling space such as that found above drop-ceiling tiles or in raised floors. A fire code for indoor cable A mathematical addition of noise from multiple disturbers. Applied to NET and ELFET requirements The amount of time it takes a signal to travel through a copper cable or system The difference in propagation delay between the slowest and fastest pairs in a copper cable or system See power sum and ELFET See power sum and NET efers to IDC connectors and the method used to terminate them Used to mount patch panels, enclosures and equipment in the telecom closet. Usually 19 wide by 7 high An electronic package that converts optical signals to electrical signals An active device used to regenerate an optical signal to allow an increase in the system length A measure of the signal reflected back toward the transmitter as a result of impedance variations in the copper or fiber cabling system Pathways for indoors cables that pass between floors. It is normally a vertical shaft of space. A fire code rating for indoor cable A wiring pattern for 6-position modular jacks A wiring pattern for8-position modular jacks Subscriber or square connector An optical waveguide in which the signal travels in one mode. The fiber has a small core diameter, typically um The permanent joining of bare fiber ends to another fiber Straight tip connector Shielded twisted pair Synchronous transport signal An electronic package used to convert an electrical information-carrying signal to a corresponding optical signal for transmission by fiber IEEE 10BASE5.10Mbps ethernet on thick coaxial cable IEEE 10BASE2. 10Mbps ethernet on thin (G58) coaxial cable A networking protocol based on a token-passing ring Cable made from pairs of wires, which have been twisted together Underwriters laboratory Unshielded twisted pair cable Vertical cavity surface emitting laser The distance between two successive points of an electromagnetic waveform Wavelength at which the chromatic dispersion of an optical fiber is zero. Occurs when waveguide dispersion cancels Out material dispersion HDCS GLOSSAY-PEMISE CABLING osenberger Asia Pacific Electronic Co., Ltd. No.3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel: (+8610) Fax: (+8610) sales@rosenberger.com.cn

90

91

92 osenberger Asia Pacific Electronic Co., Ltd. Add: No. 3 Anxiang Street, Block B, Tianzhu Airport Industrial Zone, Beijing, China Tel : (+8610) Fax: (+8610) sales@rosenberger.com.cn osenberger. All rights reserved. Designed in Germany.

ROSENBERGER HDCS ENTERPRISE CABLING SOLUTION

ROSENBERGER HDCS ENTERPRISE CABLING SOLUTION ROSENBERGER HDCS ENTERPRISE CABLING SOLUTION Rosenberger HQ, Bavaria, Germany INTRODUCTION Rosenberger Hochfrequenztechnik GmbH&Co. was founded in Germany in 1958 and ranks among the leading manufacturers

More information

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2 Product Catalogue Fiber Optic Assemblies & Adapters Table of Contents 1. General Description... 2 2. Connectors... 3 2.1 SC/UPC... 3 2.2 SC/APC... 3 2.3 FC/UPC... 3 2.4 FC/APC... 3 2.5 ST/UPC... 3 2.6

More information

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş. Technical Specification Revision/Date: 04/04.15 By N.KARAAĞAÇ Date : 27 February 2015 Cable Type HES Cable Product Number :, Outdoor F/O Cable :FOZZXXXSJSA41JYY (ZZ: fiber type G652=SD, G657 A1 = A1, G657

More information

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7 Page /7 Illustrations Product description Pre-terminated installation cables (VIK) are fiber optic cables with connectors on one or both ends that are made in manual singleitem production at METZ CONNECT

More information

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products MT-RJ Product Expansion Now 0 Variants of the MT-RJ Products In response to several customers, the MT-RJ product line has been expanded with an additional six color/key versions. In addition to the original

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE SPEC NO. TEC-OPTIC-81101A(Rev.4)-2014.07 TECHNICAL PROPOSAL FOR OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE ( Span length : Max. 100m ) APPROVED BY : J.Y. LEE / HEAD OF TEAM ENGINEERING TEAM

More information

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) 2-3, Marunouchi 2-chome, Chiyoda-ku, Tokyo 100-8322, Japan No. FB-KL4001C for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) Aug 2014 1 1. General This specification describes

More information

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference MPO/MTP TRUNK CABLE FEATURES MTP (US Conec) brand or MPO standard compliant multifiber connector Connector's design complies with IEC 61754-7 standards 4, 8, 12 and 24-fiber with single mode and multimode

More information

Fibre Optic Cable & Connector Guide

Fibre Optic Cable & Connector Guide Fibre Optic Cable & Connector Guide White paper White Paper Fibre Optic Cable & Connector Guide v1.0 EN 1 Introduction Organising through cables and connectivity options can be an exasperating exercise.

More information

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH 1 1 9.41 115 0 Pretium EDGE 143 RFP LC Uniboot to RFP LC Uniboot Patch Pretium EDGE Solutions jumpers are integrated reverse -polarity uniboot duplex assemblies that meet the high -density space requirements

More information

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY - SYMBOLS AND THE MEANING OF THE SYMBOLS FOR FIBRE OPTIC CABLES - SINGLE LOOSE TUBE, SINGLE SHEATH, NON METALLIC

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION ISSUED : OCT. 02, 2006 PAGE : 1 OF 9 REV. : 1 TECHNICAL SPECIFICATION FOR GST 2006-043A LOOSE TUBE DRY CORE CABLE SINGLE JACKET/SINGLE ARMOR (SJSA CABLE) Prepared By : Oh-Heoung Kwon Engineer Optical Technical

More information

SPECIFICATION. Optical Fiber Cable

SPECIFICATION. Optical Fiber Cable SPECIFICATION Optical Fiber Cable (GYFS) Prepared by Zhang xin Approved by Yin peng xiang 1 1 Product description GYFS is gel-free, single-jacket, single-armored cable for direct burial and duct GYFS is

More information

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection.

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection. Fibre Optic Cables & Connectors Guide Introduction Organising through cables and connectivity options can be an exasperating exercise. It's tough enough working through the categories and levels of copper

More information

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution Be ready for the future: Draka Datacom Solution Modern networks face stiff demands. They must be fast and reliable, resist fire and not interfere with other equipment. Optical Fibre Cable a fast, reliable

More information

Product Catalogue. Fibre Optic Cable

Product Catalogue. Fibre Optic Cable Product Catalogue Fibre Optic Cable version 2017 Empowering businesses through innovative network solutions. We have been pushing boundaries and providing innovative products and solutions to clients around

More information

LD Series High Performance Loose Tube Fiberoptic Cables

LD Series High Performance Loose Tube Fiberoptic Cables Fiberoptic Cables Catalog LD Series High Performance Loose Tube Fiberoptic Cables APPLICATIONS Long-distance outside plant telephone, CATV as well as data communications Direct burial and installation

More information

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC

More information

Follow The Leader In Shielded Technology

Follow The Leader In Shielded Technology 1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated

More information

FREEDM Loose Tube Interlocking Armored Cables

FREEDM Loose Tube Interlocking Armored Cables features and benefits Flexible, interlocking armor design Gel-free waterblocking technology Color-coded tubes and fibers UV-resistant, flameretardant jacket UV-Resistant Flame-Retardant Outer Jacket InterlockingArmor

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents: No.10 for Fiber Optic Cables.pdf Cable Characteristics: DESCRIPTION: 2 to 12 optical fibers, Central gel filling

More information

OPTICAL FIBRE CABLE NETWORK 2004/1

OPTICAL FIBRE CABLE NETWORK 2004/1 OPTICAL FIBRE CABLE NETWORK 2004/1 HELKAMA OPTICAL FIBRE CABLES Cabled optical fibre characteristics OS1 singlemode fibre SM ITU-T G.652 Mode field diameter 1310nm 9.3+/-0.5µm Mode field eccentricity 1.0

More information

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information. GUXT Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 4 6 8 12 16 24 62.5/125-OM1

More information

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH 1 1 9.41 115 0 Pretium EDGE 143 RFP LC Uniboot to RFP LC Uniboot Patch Pretium EDGE Solutions jumpers are integrated reverse -polarity uniboot duplex assemblies that meet the high -density space requirements

More information

Empowering businesses through innovative network solutions.

Empowering businesses through innovative network solutions. Empowering businesses through innovative network solutions. We have been pushing boundaries and providing innovative products and solutions to clients around the world for nearly two decades. Our experience

More information

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3 Version GYFTY-V1.0 Optical Fibre Cable Technical Specification Duct Cable GYFTY-24,48,72,144,216B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved 1. Scope This Specification

More information

Jacketed Fiber 900 µm. FC Ultra PC Blue boot represents ª 55 db reflectance. FC Angled PC. SC Ultra PC. SC Angled PC. LC Ultra PC.

Jacketed Fiber 900 µm. FC Ultra PC Blue boot represents ª 55 db reflectance. FC Angled PC. SC Ultra PC. SC Angled PC. LC Ultra PC. Connector Types Jacketed Fiber 900 µm FC Ultra PC FC Ultra PC FC Ultra PC FC Angled PC FC Angled PC SC Ultra PC SC Angled PC SC Ultra PC SC Angled PC FC Angled PC SC Ultra PC SC Angled PC LC Ultra PC LC

More information

Micro duct Cable with HDPE Sheath for Installation by Blowing

Micro duct Cable with HDPE Sheath for Installation by Blowing Optical Fiber Cable Technology Specification INTERNAL Optical Fiber Cable Specification Micro duct Cable with HDPE Sheath for Installation by Blowing GCYFY-12/24/36/48/72/96/144/288/432/576B1.3 V7.0 2018-3-20,CCopyright.

More information

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:00 Date: 08.03.2010 SPECIFICATION OF 192F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-192/SM/MTY(F)-MFN-O9.1 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

FIBRE OPTIC CABLE SOLUTIONS

FIBRE OPTIC CABLE SOLUTIONS point2point FIBRE OPTIC CABLE SOLUTIONS Introduction From patch-leads through to cross-site cables, or optical adapters through to patch panels, PPM s one-stopshop approach to fibre optic cable management

More information

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH 1 1 9.41 115 0 Pretium EDGE 143 RFP LC Uniboot to RFP LC Uniboot Patch Pretium EDGE Solutions jumpers are integrated reverse -polarity uniboot duplex assemblies that meet the high -density space requirements

More information

HI-DEX PRODUCT SET DATASHEET

HI-DEX PRODUCT SET DATASHEET APPLICATION HI-DEX is an ultra high-performance, pre-terminated and modular optical fibre cabling system based on MT ferrule connector technology. This product set is designed for installationn in the

More information

SPECIAL SPECIFICATION 6559 Telecommunication Cable

SPECIAL SPECIFICATION 6559 Telecommunication Cable 2004 Specifications CSJ 0015-09-147, etc. SPECIAL SPECIFICATION 6559 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing, training,

More information

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information GUWN Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 4 6 8 12 16 24

More information

CATEGORY 5e CABLING SOLUTIONS

CATEGORY 5e CABLING SOLUTIONS With the high speed data transmission requirement in LAN, 1998 IEEE ratified standard 802.3z defined protocol 1000BASE-T over Category 5e and higher level Ethernet cabling system. After that, with the

More information

Compact Module. Category 6 FTP Cabling System

Compact Module. Category 6 FTP Cabling System Compact Module Shielded design for improved EMI performance Suitable for Gigabit Ethernet applications and beyond Ultra-slimline design Colour coded for quick and accurate termination Interchangeable with

More information

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011 SECTION 271323 - COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING PART 1 - GENERAL 1.1 DESCRIPTION A. This section provides the specifications for the work related to the optical fiber system in the project.

More information

Mining and Petrochemical Fiber Optic Cables

Mining and Petrochemical Fiber Optic Cables Features and Benefits Loose construction Stable and highly reliable transmission parameters Waterblocking technology Allows efficient and craft-friendly cable preparation in outdoor or indoor/outdoor applications

More information

PREMIUM 5e F/UTP PRODUCTS

PREMIUM 5e F/UTP PRODUCTS Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been

More information

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:01 Date: 07.10.06 SPECIFICATION OF 96F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-96/SM/MTY(F)-MFN-O6.3 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

Enterprise Networks. Comms Room and Backbone. in DETAIL

Enterprise Networks. Comms Room and Backbone. in DETAIL Enterprise Networks Comms Room and Backbone in DETAIL 31 Patch Panels 33 CAT 6 CL 16 WAY PATCH PANEL 19 1U Category 6 performance patch panel. Jacks are fitted. Integral cable management and reusable label

More information

Revision No. 4 Page No. Page 1 of 7

Revision No. 4 Page No. Page 1 of 7 Page No. Page 1 of 7 Single Mode Optical Fibre Cables With Loose Fibres in Stranded Tubes And Corrugated Steel tape Armouring For Duct Applications LITE KABEL SDN. BHD. reserves the right to make changes

More information

CATEGORY 6 CABLING SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS With over 20 years experience and know-how on communicating products design & developing, Premium Line has built maturity systems both in high tech develop and research center & complete structural quality

More information

Preferred ordering guide for NETCONNECT

Preferred ordering guide for NETCONNECT Preferred ordering guide for NETCONNECT MEA Region Contents Copper solutions Category 6A products 3 Category 6A and Category 7 shielded copper cables 3 Category 6A modular shielded panels 3 Category 6A

More information

SPECIAL SPECIFICATION 8540 Telecommunication Cable

SPECIAL SPECIFICATION 8540 Telecommunication Cable 2004 Specifications CSJ 0914-00-307 & CSJ 0914-25-003 SPECIAL SPECIFICATION 8540 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing,

More information

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue. Description: OZLINX CAT5e cable has a guaranteed performance; exceeds the Category 5e performance requirements and provides positive PSACR up to 155MHz for bandwidth requirement in the future. Product

More information

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer Spec No.: ZTT 45012 Revision: 2 Date: Oct 3, 2014 TECHNICAL SPECIFICATION Optical Fiber Cable (Reference: NBR 14566) Designer Senior Technical Manager Approver Chief Technical Engineer Jiangsu Zhongtian

More information

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS 10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Premium Line Category 6A Cabling Solutions

More information

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available Fiber Optic Products FIBER OPTIC PRODUCTS FIBER OPTIC PATCH CORD CABLE The Construction of a Fiber-Optic Cable Cable Jacket - The outermost layer of the fiber cable. Strengthening fibers - The strengthening

More information

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS 10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Need of 10 Gigabit Service Application as

More information

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE Prepared in cooperation and approval from BICSI Building Industry Consulting Services International and

More information

Ø 1000 * 588 mm 50 kg

Ø 1000 * 588 mm 50 kg GOCN Central Loose Tube Cables Outdoor Corrugated Steel Tape Armor (CST) A-DQ(ZN)(SR)2Y Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 4 6 8 12 16 24 62.5/125-OM1

More information

The World Of Professional Fiber Optics. safe flexible reliable

The World Of Professional Fiber Optics. safe flexible reliable The World Of Professional Fiber Optics safe flexible reliable CONTENTS Contents General Info.... 3 2-Channel System.... 6 4-Channel System.... 10 SMPTE System.... 15 Patchcords.... 19 Accessories.... 21

More information

Mini-breakout & Mini-bundle cable. Riser cabling solution

Mini-breakout & Mini-bundle cable. Riser cabling solution Mini-breakout & Mini-bundle cable Riser cabling solution Mini-breakout & Mini-bundle cable Riser cabling solution CommScope s riser cables are developed for fast installations in MDUs. Their compact design

More information

STRUCTURED CABLING SYSTEMS (SCS)

STRUCTURED CABLING SYSTEMS (SCS) STRUCTURED CABLING SYSTEMS (SCS) ModSecur - Structured Cabling Systems (SCS) A Structured Cabling System (SCS) is the backbone of any building, campus or site communication infrastructure. The sharp growth

More information

1. General. 1. Scope. 2. Quality Assurance

1. General. 1. Scope. 2. Quality Assurance 1. General 1. Scope 2. Quality Assurance This specification covers the construction and properties of 50/125 um Multimode (Graded-index, OM2), anti-rodent self-supporting (ARSS), single jacket, single

More information

Cable Installation Tips

Cable Installation Tips Cable Installation Tips Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/)

More information

SECTION FIBER OPTIC STATION CABLES

SECTION FIBER OPTIC STATION CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications shall include all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV FIBER OPTIC CABLES ASTEL offers an innovative and wide range of Optical Fiber Cables from 4 Fiber to 144 Fibers for broadband networks. ASTEL offers variety of models from Uni-Tube construction, to Stranded

More information

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting) 2004 Specifications CSJ 0086-14-046 SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting) 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials.

More information

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52 cable assemblies Assembly code page 46 Cable code page 47 Assembly classes page 48 Polarization maintaining assemblies page 52 45 Assembly: Ordering code Description cable type 27H01CD0- see cable code

More information

CUSTOM-LENGTH PATCH CABLES CUT-TO-LENGTH BULK FIBER PRE-TERMINATED FIBER MULTI-COLORED FIBER

CUSTOM-LENGTH PATCH CABLES CUT-TO-LENGTH BULK FIBER PRE-TERMINATED FIBER MULTI-COLORED FIBER CUSTOM-LENGTH PATCH CABLES CUT-TO-LENGTH BULK FIBER PRE-TERMINATED FIBER MULTI-COLORED FIBER 1.877.877.2269 BLACKBOX.COM OUR CUSTOM CAPABILITIES When you re looking for specialized copper or fiber cables

More information

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

SPECIAL SPECIFICATION 6191 Fiber Optic Cable 2004 Specifications CSJ 0014-02-014, etc SPECIAL SPECIFICATION 6191 Fiber Optic Cable 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials. A. General

More information

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box. FTTH & FITH Discreet optical fiber solutions from the network connection point to the set-top box www.omelcom.com FIBER: THE FUTURE IS HERE The past several years have seen major progress in the penetration

More information

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents WESLEYAN U N I V E R S I T Y Facilities 170 Long Lane Middletown, Connecticut 06457 (860) 685-3476 FAX (860) 685-3101 ADDENDUM #3 Date: March 4, 2013 Project: To: CFA A Rehearsal Hall AHU Replacement Annual

More information

Number of Fiber 6 Core 12 Core. Part Number

Number of Fiber 6 Core 12 Core. Part Number Order Information OUTDOOR OFC-Drop Wire, MM (OM2) (50/125) LOOSE TUBE BLACK Number of Fiber 6 Core 12 Core Part Number 74550006 74550012 1. General 1. Scope 2. Quality Assurance This specification covers

More information

Cable Installation Tips

Cable Installation Tips Cable Installation Tips Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/)

More information

Singlemode Patch Cords and Pigtails

Singlemode Patch Cords and Pigtails Singlemode Patch Cords and Pigtails TECHNICAL DATA Description ADC KRONE offers a wide array of singlemode fibre optic patch cords, featuring Riser and LSZH cables. ADC KRONE s singlemode connectors are

More information

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications E2O540JCASS-12CT MICFIBR-12.7MB MICFIBR-12.7MB DUCT DUCT E2O540JCASS- Product Classification Brand E 2 O E 2 O Coaxial/Fiber/Microduct Hybrid Buried Cable E O is a solution that enables service providers

More information

Best Friends General Trading FZE

Best Friends General Trading FZE Welcome to Best Friends General Trading FZE Tel. +97 1 50-5426 202, Fax. +971 6 7407428, info@bestfgt.com, besttrd@eim.ae Infrastructure Product Guide Best fgt is UAE based company, operational for last

More information

SOLO ADSS Short-Span Cables, Fibers

SOLO ADSS Short-Span Cables, Fibers features and benefits Loose tube design Self-supporting Track-resistant jacket available Innovative waterblocking cable core SOLO ADSS Cable Drawing ZA-2615 Stable performance and compatibility with all

More information

Structured Cabling. Product Line Brochure

Structured Cabling. Product Line Brochure Structured Cabling Product Line Brochure High Performance and Reliable Solution Infinique structured cabling products are manufactured to international standards and are certified for performance and

More information

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business 3M Telecommunications Solutions for Networks 3M MPO solutions High Density Networks Technology built for business 2 3M Telecommunications Solutions for Networks 3M Telecommunications Solutions for Networks

More information

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1 Modular Solutions Subject to technical changes! 1 Since 1986, braun telecom has stood for continuity and competence in broadband communication and has become one of the leading suppliers of products and

More information

Connectivity accessories by Nestor Cables

Connectivity accessories by Nestor Cables Connectivity accessories by Nestor Cables NesCon product family includes essential installation and connection accessories for fibre optic networks, from ODFs to joint closures and terminations. www.nestorcables.com

More information

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017 Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM-2017-2 Date: 05/26/2017 Additional specification information for data communication to cameras and between Library

More information

GATOR PATCH. The ultimate fiber distribution terminal

GATOR PATCH. The ultimate fiber distribution terminal The ultimate fiber distribution terminal PRODUCT OVERVIEW Rugged, Fast, Reliable! Trust the original Gator Patch for all your fiber distribution needs The Gator Patch is a unique, rugged, factory terminated

More information

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits GBRE Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 84 96 62.5/125-OM1 GBRE184 GBRE196 -OM2 BW /1200 GBRE284

More information

Jumpers & Pigtails. Fiber Type OM1, OM3, OM4, 0S1/OS2. Polarity Correction SC and LC duplex clip allows for polarity correction

Jumpers & Pigtails. Fiber Type OM1, OM3, OM4, 0S1/OS2. Polarity Correction SC and LC duplex clip allows for polarity correction XGLO and LightSystem Jumpers & Pigtails XGLO fiber optic cable assemblies are ideal for supporting duplex and simplex fiber applications over extended distances and next-generation backbones. XGLO cable

More information

HITRONIC Optical Transmission Cable

HITRONIC Optical Transmission Cable HITRONIC Optical Transmission Cable POF - Polymer Optical Fiber 263 PCF - Plastic-Clad Fiber 267 GOF - Glass Optical Fiber 269 HITRONIC Optical Transmission Cable OPTICAL TRANSMISSION CABLE POF - Polymer

More information

Public Works Division Lighting District Fiber Optic Specifications April 2009

Public Works Division Lighting District Fiber Optic Specifications April 2009 Public Works Division Lighting District Fiber Optic Specifications April 2009 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks

More information

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS) SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS) No. FT-S16274 Version: A (ITU-T Rec. G.652.D) Futong Group Communication Technology (Thailand) Co., Ltd. All Right Reserved Add: No.7/324, Moo 6, T.Mabyangporn

More information

Connectix Cabling Systems

Connectix Cabling Systems Connectix Cabling Systems Cabling Standards and CPR Update Connectix CEP Fibre Optic Solutions Jason Holroyd CNID Director of Business Development Types of fibre Agenda Introduction Uses Construction Transmission

More information

Game on! Plug n play. Plug and play with PryTerms our pre-terminated fibre optic cables. Read more

Game on! Plug n play. Plug and play with PryTerms our pre-terminated fibre optic cables. Read more Game on! Plug and play with PryTerms our pre-terminated fibre optic cables. Plug n play Read more Plug and play with PryTerms Have you ever been in a potentially dangerous or really cramped place trying

More information

NO MORE LOOSE ENDS PRE-TERMINATED FIBER CABLE: FAST. TESTED. READY TO GO (BBOX) BLACKBOX.COM/PRETERMFIBER

NO MORE LOOSE ENDS PRE-TERMINATED FIBER CABLE: FAST. TESTED. READY TO GO (BBOX) BLACKBOX.COM/PRETERMFIBER NO MORE LOOSE ENDS PRE-TERMINATED FIBER CABLE: FAST. TESTED. READY TO GO. BBOX APPLICATIONS PANELS & BBOX APPLICATIONS & MARKETS ICON SET ESSORIES PRE-TERMINATED FIBER CABLE AWARD WINNING CONNECTORS, ADAPTERS

More information

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Number of Fiber 12 Core 24 Core 48 Core. Part Number Order Information OUTDOOR OFC-FIG.8, MM (OM2), (50/125) LOOSE TUBE BLACK 1. General 1. Scope 2. Quality Assurance Number of Fiber 12 Core 24 Core 48 Core Part Number 63460012 63460024 63460048 This specification

More information

OPTICAL CABLE FIBER-LAN INDOOR

OPTICAL CABLE FIBER-LAN INDOOR OPTICAL CABLE FIBER-LAN INDOOR Product Type Optic Cable Construction RoHS-2 Compliant Dielectric Tight Buffer Singlemode or Multimode Description Optical cable with singlemode or multimode optical fibers

More information

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content Page 1 of 10 GENERAL A fiber optic cable system is very similar to a copper wire system in that it is used to transmit data

More information

MPS Webinar Technical Series

MPS Webinar Technical Series MPS Webinar Technical Series Making Connections: Navigating Fiber Optic Cabling and Interconnection Requirements microwave photonic systems Expand Your RF Horizons Introduction Microwave Photonic Systems

More information

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12) FAML1UC0C OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12) Fiber Type Total Fibers, quantity 12 Cord Length, maximum 23 ft 7 m Cord Length,

More information

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Product information 19 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated R512417 966740615 1 Pcs. 090.6102 Metal patch panel with integrated cable tie shelf. 19" 1U HD patch panel 4 12-port/s

More information

for FOSTEC INC. 1/ 15

for FOSTEC INC. 1/ 15 TECHNICAL SPECIFICATION for OPTICAL FIBER PATCH CORD / PIGTAIL FOSTEC / 5 . Scope: This specification is applicable to optical fiber patch cord, pigtail and with w optical connectors. The pigtail is single

More information

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12 Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12 Our I-IFLRF20 series is a wideband RF over fiber link that provides optical transport of RF signals in radars, satcom, EW/ECM and other antenna remoting

More information

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY ADVANTAGES OF FIBER OPTIC CABLE Fiber optic cable is the preferred choice for backbone and horizontal applications. Black Box provides

More information

PreCONNECT Mobile PRODUCT INFORMATION

PreCONNECT Mobile PRODUCT INFORMATION PreCONNECT Mobile PRODUCT INFORMATION PreCONNECT Mobile TRUNK Model 1 Model 2 Chaining Kit Stackable Product information: Produktinfo_PreCONNECT_MOBILE_oe_001 Author : Yunhua Zhang Page 2 of 11 Applications:

More information

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports RJ45 - Cat. 6A Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports Compatible with FO trunks Modern data centre trunk solution in modular cassette technology Pre-terminated

More information

Empowering businesses through innovative network solutions.

Empowering businesses through innovative network solutions. Empowering businesses through innovative network solutions. We have been pushing boundaries and providing innovative products and solutions to clients around the world for nearly two decades. Our experience

More information

Fiber Optics Redefined

Fiber Optics Redefined Fiber Optics Redefined Questions and Answers on the basics of fiber optic installation TECHLOGIX NETWORX Questions & Answers Questions and Answers Q: What are the two main types of fiber? A: The two main

More information

Copper Solution Contents Cabinets Fiber Optic Solution

Copper Solution Contents Cabinets Fiber Optic Solution Contents Copper Solution Category 6A + Cabling Solutions Cat.6A + 1000MHz S/FTP Installation Cable A1 Cat.6A + S/FTP Patch Cord A2 Cat.6A + 90 Fully Shielded Die-casting Keystone Jack A3 Modular German

More information