This presentation will give you a general idea of the subjects on the 18 CATV-HFC seminars that are available from:

Size: px
Start display at page:

Download "This presentation will give you a general idea of the subjects on the 18 CATV-HFC seminars that are available from:"

Transcription

1 This presentation will give you a general idea of the subjects on the 18 CATV-HFC seminars that are available from: 1

2 Broadband System - A Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (1)-CATV TV TRANSMITTER Headend Cable area 2

3 CATV : Community Antenna TV television CATV systems started in around 1952 and were a one way communication system, using coaxial cable and RF amplifiers. These CATV systems distributed television signals, from a distribution center (Head end) to all the homes in a the cabled area. These systems then, were capable of only distributing between 2 to 4 TV channels. From been able to distribute 2 to 4 TV channel at their start, some of the systems finally carried as much as 12 television channels and some FM music. 3

4 0 6.0 MHz Video section 4.2 MHz Analog technology -30 db Audio section 0.9 MHz FM technology Color section MHz 4.5 MHz 4

5 Coaxial cable consist of : 75 ohms cable. Center conductor. Foam (hold the center conductor in place) Aluminum tube. Sometimes covert with PVC jacket. Coaxial cable is the most common way to distribute television channel. His frequency range is from: 5 to 1000 MHz It is also capable of handling 90 Volts AC requires to operate RF amplifiers. 5

6 Broadband System B Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (2)-Head end of a CATV-HFC system. TV TRANSMITTER Headend Cable area 6

7 Welcome to a Seminar on Broadband Network. Here are the subjects that we will be covering during future seminars; The Coaxial cable. The RF section of the Broadband system. The fiber optic section of the CATV-HFC system. The Distortions on a Broadband system. The Passives equipments. The Maintenance of the CATV, HFC system. The Test equipments needed for a Broadband system. Understanding Bi-directionality of a Broadband system. Understanding Cable modem, QPSK, 64 and 256 QAM signal. More on DOCSIS. 7

8 Head end Equipment for a Broadband System. 44 channels Combining network. Front end test point. Head end equipment connection. 8

9 Combining a Head end for a Broadband System. Combining Network from 50 to 870-1,000 MHz Sometime an RF amplifier Can be required. 9

10 Broadband System C Satellites are spaced every 2n degr es abov earth "C" Band Toward satellite 6.0 GHz "L" Band Toward earth 4.0 GHz Toward satellite 14.0 GHz Toward earth 12.0 GHz TV TRANSMITTER Headend Cable area Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (3)-Headend Instruments CATV-HFC TV TRANSMITTER Headend Cable area 10

11 Head end Antennas. An antenna installation, may demand many different equipments. 11

12 Head end of a Broadband System. 12

13 Broadband System - D Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (4)-Coaxial Cable and Fibre Optic. TV TRANSMITTER Headend Cable area 13

14 Coaxial Cable. Return Loss. When the cable impedance is not exactly 75 ohms, there will be an impedance mismatch and a reflection of energy if it is connected to an ideal 75 ohms signal source. This reflection can be quantified in terms of the return loss: RL = 20 LOG Z DEVICE - Z0 Z DEVICE + Z0 Where Z DEVICE is the complex characteristic impedance of the device (ohms) and Z0 is 75 ohms for CATV system. Since the cable impedance is within a few ohms of 75, the return loss, as opposed to the cable s structural return loss, is very good and usually better then 37 db. The structural return loss, which deals with return loss at particular frequencies, will be discussed next. 14

15 Coaxial Cable Behaviour with Temperature. One more problem with coaxial cable and temperature changes, is the moving of the cable while been supported by the strand. Coaxial cable will required expansion loops at each pole to minimized this movement, weather there is equipment or not at each pole location. Where equipment should be placed 15

16 How Fibre Optic is Made. Below is a fibre which consist of the CORE where light is been propagated, CLADDING which keep the light inside the CORE and BUFFER which is colour coated and permit the identification of the fibre. 16

17 Fibre Optic Cable. Loose tube fibre Ribbon fibre Fibre optic cable comes in many flavours, most common flavours, are losses tube fibre and ribbon fibre. These fibre cables can also be armoured for duck placing or buried installation or just plain jacketed for aerial placing. Arial Fibre Optic Cable Figure 8 Fibre Optic Cable Armoured Fibre Optic Cable 17

18 Broadband System - E Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (5)-Passive Equipments. TV TRANSMITTER Headend Cable area 18

19 Passive Equipment in a Broadband System The Power Inserter is the junction between the coaxial system and the power supply, it introduce 60 or 90 Volts AC from the Power Supply. The Power Inserter are usually capable of handling 20 amperes. Fuses can be installed on each leg for better protection. 19

20 Passive Equipment in a Broadband System Example of the input signal required and the thru loss at a multi tap supplying: dbmv level at the customer s drop. Thru loss of the multi tap: MHz Input Level: 34.0 dbmv Output Level: 32.3 dbmv 16 dbmv output At 870 MHz. 20

21 Broadband System F Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (6)-CATV-HFC Outside Plan. TV TRANSMITTER Headend Cable area 21

22 Outside Plan. 22

23 Outside Plan Equipments. Cable been lashed 23

24 Broadband System - G Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (7)-CATV-HFC RF Amplifiers. TV TRANSMITTER Headend Cable area 24

25 RF Amplifiers Selecting the right amplifier, usually require a amplifier with forward and a return path section. The forward amplifier required for today s needs are either: 50 to 750, 50 to 870 and 50 to 1,000 MHz bandwidth. The return path can be from: 5 to 40 / 42 or 5 to 65 MHz ,000 MHz ,000 MHz 25

26 RF Amplifiers Type of amplification circuit used in modern RF amplifiers; Single ended transistor Single ended transistor Push Pull transistor 180 Push Pull transistor Power Doubling transistor To day s Circuitry can be: Push pull Power Doubler GaAs 26

27 fuse fuse RF Amplifiers A One Output, High Gain Amplifier. 870 MHz 50 MHz 870 MHz 50 MHz 50 MHz 870 MHz to status monitoring -20 db 40 MHz 5 MHz JXP RF AC RF/ AC 870 MHz RF/ AC AC RF -20 db EQ JXP BODE BRD JXP 50 MHz 5 40 MHz MHz 5 40 MHz MHz Manual Gain Control ADU JXP -20 db -20 db EQ JXP 5 MHz 40 MHz from status monitoring JXP -16 db ICS Drive ICS JXP to status monitoring 24 Vdc vcc Power Supply 90 / 60 Vac fuse 38 db gain, minimum 1,000 MHz. 27

28 RF Amplifiers with an AGC control. Input next amplifier after 30 db cable spacing at 870 MHz o Temperature 870 MHz From - 40 C to + 40 C o 21 Temperature 300 MHz From -40 C to + 40 C o Signal after cable equalizer AGC Ch. 28

29 Broadband System - H Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (8)-Fibre Optic. TV TRANSMITTER Headend Cable area 29

30 Fibre Optic Milestones John Tyndall demonstrated the optical waveguide principle Theodore Maiman developed the first laser db/km loss fibre fabricated Single mode fibre optic first reported SONET telecommunications standards created DWDM deployment began > 1 Tbps demonstrated on one fibre L-Band System and 40 Gbps transport system demonstrated. 30

31 Optical Transmitter. Electrical to Optical (E-O) Converter Light Out Electrical In - + Variable Intensity = Analog Blink On & Off = Digital 31

32 Classifying Light. Power (Watts or Decibels) dbm is typical measurement unit of optical power It is measured with a: Optical Power Meter Color (Wavelength) 300nm (blue) to 700nm (red) is visible to humans eyes. Fiber Optic systems use ONLY Infrared (850, 1310, & 1550nm) Visible Light Spectrum UV IR 300nm 700nm 32

33 Broadband System - I Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (9)-Fibre Optic Management System. TV TRANSMITTER Headend Cable area 33

34 Interconnection Outside to Inside Fibre mounted in a frame rack. From the Interconnection centre, the fibre optic cable usually goes to a connection rack, which can be 19 or 23 wide. The CATV industry uses 19 frame. The TELCO industry uses a 23 frame. These racks contains Fibre Interconnection System, Passive equipments and Transmission and receiving Equipments. 34

35 Fibre optic COUPLER / SPLITTER One NODE feed from single optical transmitter Optical Transmitter NODE Two NODES feed with outside optical coupler Optical Transmitter NODE Optical Coupler NODE Optical Transmitter Two NODES feed with inside optical coupler NODE NODE Optical Coupler 35

36 Fibre Interconnection Centre STUB Cable Connecting section Often a connecting housing will be order with a STUB cable. This stub cable will then be connected at one end with proper connectors and the other end will be spliced to the junction box. This STUB cable needs to be FT-4 or FT-6, which are flamed retarded cable. FT-4 is used when the cable stay on the same floor, and FT-6 is used when the cable goes from floor to floor. This STUB cable can be of any length, sometime as much as 150 mt. 36

37 Broadband System - J Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (10)-CATV-HFC System Distortions TV TRANSMITTER Headend Cable area 37

38 Distortions in a Broadband System. In this section we will learn how to calculate the distortions in a Broadband System. This presentation will help understand, why the system performs better closer to the head end and get worst, toward the end of the system. 38

39 Distortions in a Broadband System. Here are the distortions we will covering in this section; Distortion of second order. Distortion of third order Cross modulation. Composite third order, CTB. Composite second order, CSO. Noise. Hum. 39

40 Distortion in a Broadband System. CTB & X-Modulation calculation of a cascade of RF amplifiers. Xmod. CTB. 20log log * 10 log10 ( -XM 1 + -XM 2 ) Cross modulation & CTB: Are always given as negative number. 20 * 10 log10 ( -XM 1 + -XM 2 ) * 10 log10 ( -XM 1 + -XM 2 ) For each db change in output level, the change of CTB and Xmod. is 2.0 db. Each time we double the cascade, CTB and Xmod. get worse by 6.02 db. 40

41 Distortion in a Broadband System. All distortions. You need to calculate the distortions of the CASCADE of the RF amplifiers and then married (add) these distortions to the Optical NODE, to get the actual system s distortions. NODE CASCADE of RF amplifiers Then add the NODE distortions. 41

42 Broadband System - K Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (11)-Bi-Directionality on a Broadband System. TV TRANSMITTER Headend Cable area 42

43 Bi-Directionality on a Broadband System. All RF amplifier must be equipped with a bi-directional filter at each input and outputs to permit an HFC system to operate in a bi-directional way. Section RF 50-1,000 MHz Section RF 50-1,000 MHz 5-40 / 50-1,000 MHz Coaxial Cable Filter Bi-Directional Filter Bi-Directional 5-40 / 50-1,000 MHz Coaxial Cable Section RF 5-40 MHz Section RF 5-40 MHz 43

44 Bi-Directionality on a Broadband System. A Broadband HFC Communication system utilized two types of communications technology: Fiber optic technology is used to transport signal for the long distance. Usually one fiber transmits forward signal ( MHz from the Head end to a Optical Node and one more fiber transmits return signal (5-40 MHz) from a Node to the Head end. Coaxial cable is used from the NODE and it is transmitting in both directions ( / 5-40 MHz), from the Optical Node to the each subscribers. The OPTICAL NODE, transfers Light Signal, coming from the Head end, to Electrical Signal (RF and Digital), sending these signals to each subscribers by coaxial cable. The OPTICAL NODE, also Transfers Electrical Signal (RF and Digital) from all the customers to light signal, sending them to the Head end. 44

45 Adjusting the Return Signal on a Broadband System. Adjusting the forward section, is something, technician have been doing for year. Adjusting the reverse system is quite different, it either requires: Two technicians communicating, to properly adjust the return amplifier. 2 or 4 Modulators to be transported at each amplifier, a Spectrum Analyzer at the Head end, connected to a Modulator, and a TV set at each amplifier. Or the use specialized equipment, We need to adjust the Gain and Slope of the return amplifier at 1 to have the proper input signal level at: 2 45

46 Bi-Directionality on a Broadband System. All optical NODE must be equipped with a Photo diode on the forward path, a bidirectional filter at each output of the coaxial system to permit an HFC system to operate in a bi-directional way and a return Laser to transmit return signal toward the head end. Photo diode RF Amp. Fibre 50-1,000 MHz Fibre 5-40 MHz Filter Bi-Directional 5-40 / 50-1,000 MHz Coaxial Cable LASER 46

47 Broadband System - L Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (12)-Alignment and System Maintenance. TV TRANSMITTER Headend Cable area 47

48 Broadband Head end Combining. Combining Network 48

49 Final Adjustment of the Head end. Some test equipments are able to give you a general view of the system by the selection of some of the channels in the operating spectrum. 49

50 Final Adjustment of the Head end. Response of a well aligned head, using a sweep system. Using a sweep generator, located at the head end. The actual signal of the HFC system. 50

51 Broadband System - M Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (13)-Home Installation. TV TRANSMITTER Headend Cable area 51

52 Customer s Installation 52

53 Customer s Installation 53

54 Customer s Installation Response of a High Pass Filter for no Internet service MHz This High Pass Filter is often installed at all the customer premise, where no Cable modem service is required. This help keep the return system free of Ingress, coming from customer. 54

55 Broadband System - N Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (14)-Test Equipments Required for a HFC System. TV TRANSMITTER Headend Cable area 55

56 RF test equipment can be divided in two sections. Equipments capable of reading the strength of a Television Channels. TV channel signal strength Digital signal (Power meter) Multi channel reading (Slope or Tilt) Spectral view of all the channels carried by an HFC system C/N measurement. Distortion measuring (C-N, CTB and CSO) Frequency Response (Peak & Valley response) QAM reading (BER, MER and FEC) Return alignment tool. (Response and Ingress) Ingress reading (Leakage) 56

57 Test equipments for fibre optic communication Test equipments required for the fibre optic section are the following; Power meter. Light Source. OTDR (Optical Time Domain Reflect meter). OSA (Optical Spectrum Analyser). Talk Set. Visual Fault Locator Optical Fibre Identifier. Optical Scope. PMD Analyzer. 57

58 ield trength eter 0 Video 300 to 400 KHz 6.0 MHz Audio 300 to 400 KHz Most FSM read between 300 to 400 KHz of band width How it is display on the Field Strength Meter -30 db MHz 4.5 MHz 58

59 Power meter. Power meter are required to measure the power output of the optic transmitting equipment, the input of the receiving equipment and the actual loss of a fibre optic link. GN-6025 Freq.: 800 to 1700 nm. +5 to 70 dbm GN-6025C * Freq.: 800 to 1700 nm. +20 to 60 dbm * Best for HFC system. 59

60 OTDR (Optical Time Domain Reflect meter) Printed view of two fibre optic links measurements. 60

61 Broadband System O Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (15)-CLI Cumulative Leakage Index TV TRANSMITTER Headend Cable area 61

62 Leakage Terminology Radiation. Egress Ingress Leakage uv M (Micro volts per Meter) CLI (Cumulative Leakage Index) 62

63 Ingress / Egress Ingress: RF signal leaking into the coaxial plant. Egress: RF signal leaking out of the coaxial plant. 63

64 Broadband System P Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (16)-DOCSIS, QPSK, QAM signal and Cable Modem System. TV TRANSMITTER Headend Cable area 64

65 Understanding DOCSIS Operating System. A Cable system operating with Cable Modems required, A bi-directional HFC or CATV system. A Cable Modem Termination System at the Head end or Hub site. A 100 BaseT or better connection to Internet or Servers. A 6 MHz of 64 or 256 QAM data channel operating from: 88 to 870 MHz. A 3.2 MHz of QPSK or 16 QAM operating between 16 to 40 MHz on the return section of the system for DOCSIS 1.0. At least one Cable Modem installed at a customer on the system. 65

66 Understanding DOCSIS Operating System. One other standard that will be repeated very often in the following lecture; CMTS. Cable Modem Termination System The above unit is what controls all the data to and from all Cable modem on the HFC system. 66

67 Understanding DOCSIS Operating System. Nominal DOCSIS Downstream Data Rate in 6-MHz Channel Modulation type 64 QAM 256 QAM Symbol rate MSs MSs Total data rate Mbps 42.9 Mbps Effective data rate 27 Mbps 38 Mbps Nominal DOCSIS Upstream Data Rate for QPSK Bandwidth 200 khz 400 khz 800 khz 1600 khz 3200 khz Symbol rate 0.16 MSs 0.32 MSs 0.64 MSs 1.28 MSs 2.56 MSs Total data rate 0.32 Mbps 0.64 Mbps 1.28 Mbps 2.56 Mbps 5.12 Mbps Effective data rate 0.3 Mbps 0.6mbps 1.2 Mbps 2.3 Mbps 4.6 Mbps Nominal DOCSIS Upstream Data Rate for 16 QAM Bandwidth 200 khz 400 khz 800 khz 1600 khz 3200 khz Symbol rate 0.16 MSs 0.32 MSs 0.64 MSs 1.28 MSs 2.56 MSs Total data rate 0.64 Mbps 1.28 Mbps 2.56 Mbps 5.12 Mbps Mbps Effective data rate 0.6 Mbps 1.2 Mbps 2.3 Mbps 4.5 Mbps 9.0 Mbps 67

68 Broadband System - Q Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz (17)-DOCSIS Simplify. TV TRANSMITTER Headend Cable area 68

69 DOCSIS Simplified Data Over Cable Service Interface Specification (DOCSIS) is an international standard DOCSIS which defines the communications and operation support interface requirements for data over cable system. It permits the addition of high-speed data transfer to an existing cable TV (CATV) system. It is employed by many cable television operator to provide Internet access over their existing hybrid fibre coaxial (HFC) structure. The first DOCSIS specification was version 1.0 issue in March 1997, with revision 1.1 following in April of Because of increased demand for symmetric, real-time service such as IP telephony, DOCSIS was again revised to enhance upstream transmission speed and (QoS)Quality of Service; this revision - DOCSIS 2.0 was released in January

70 DOCSIS Simplified DOCSIS 3.0 The new DOCSIS 3.0 standard that features IPv6 and channel bonding which enables multiple downstream and upstream channels to be used together at the same time by a single subscriber. DOCSIS 3.0 Downstream speed is 160 Mbps and 120 Mbps Upstream. Channel bonding in computer is an arrangement in which two or more NETWORK INTERFACE on a host computer are combined for redundancy or increased throughput. Internet Protocol Version 6 (IPv6) is a network layer IP standard used by electronic devices to exchange data across a packetswitched internet work. It follows IPv4 as the second version of the Internet Protocol to be formally adopted for general use.. 70

71 DOCSIS Simplified Speed Test Summary At my home in Montreal, Quebec, Canada Date: Time: Date: Time:

72 DOCSIS Simplified Throughput Calculations Downstream DS symbol rate = Symbols/s or Mbaud. A filter roll-off (Alfa) of about 18 % gives X (1+.18)= ~6 MHz wide haystack as shown in figure 3-30 db 6 MHz 64=2 to the 6 th power. Using the exponent of 6 means six bits per symbol for 64 QAM and would give X Mbps. After the entire FEC and MPEG overhead is calculated, this leaves about 28 mbps for payload. This payload is further reduced MHz because it s also shared with DOCSIS signalling. figure 3 72

73 These presentations should give you a good idea of the way these seminars are presented. If you require more information, please get in touch with us at: lamarrea@videotron.ca Tel: < Click on the upper arrow on your browser to go back to previous page. 73

Broadband System - K

Broadband System - K Broadband System - K Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz TV TRANSMITTER Headend

More information

Broadband System - D

Broadband System - D Broadband System - D Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz TV TRANSMITTER Headend

More information

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration (Choice s experience) Installation and configuration (cont.) (Choice s experience) DOCSIS 3.0 Components M-CMTS deployment DTI Server Edge QAM Modular CMTS I-CMTS Integrated CMTS Integrated DOCSIS 3.0

More information

TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC

TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC Originally appeared in the July 2006 issue of Communications Technology. TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC Digitally modulated signals are a fact of life in the modern cable

More information

OPTICAL DISTRIBUTION STATION -

OPTICAL DISTRIBUTION STATION - optical distribution station is a high performance, four individual outputs node. With high output levels and performance to 862MHz, it provides an ideal platform for support of the evolving technologies

More information

Catv Expert

Catv Expert My way of chasing INGRESS and NOISE on the return path of a CATV-HFC system. J. A. André (Andy) Lamarre Senior member SCTE (USA). Catv Expert http://www.catvexpert.com Before we get going on this subject,

More information

Amplifiers STARLINE 2000 Broadband Telecommunications Distribution Amplifier [BT*/*]

Amplifiers STARLINE 2000 Broadband Telecommunications Distribution Amplifier [BT*/*] mplifiers STRLINE 2000 Broadband Telecommunications Distribution mplifier [BT*/*] FETURES 750 MHz and 870 MHz power doubling technology in Gas or silicon 60/0V powering Meets IEEE C62.41 11 and BellCore

More information

DVO700 P FIBRE OPTIC TRANSMITTER

DVO700 P FIBRE OPTIC TRANSMITTER Timo Rantanen September 24, 2002 1(5) FIBRE OPTIC TRANSMITTER is a high performance, extremely linear externally modulated 1550 nm transmitter for DVO fibre optic CATV link. This transmitter type has been

More information

MIGRATION TO FULL DIGITAL CHANNEL LOADING ON A CABLE SYSTEM. Marc Ryba Motorola Broadband Communications Sector

MIGRATION TO FULL DIGITAL CHANNEL LOADING ON A CABLE SYSTEM. Marc Ryba Motorola Broadband Communications Sector MIGRATION TO FULL DIGITAL CHANNEL LOADING ON A CABLE SYSTEM Marc Ryba Motorola Broadband Communications Sector ABSTRACT Present day cable systems run a mix of both analog and digital signals. As digital

More information

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters Issues SNMP Traps to Notify User of Problems Ability for Remote Control Lets Users Take a Closer Look Without

More information

Review of the Comcast. Fort Collins Cable System. Technical Characteristics

Review of the Comcast. Fort Collins Cable System. Technical Characteristics Review of the Comcast Fort Collins Cable System Technical Characteristics Prepared by: January 30, 2004 Dick Nielsen Senior Engineer CBG Communications, Inc. Introduction and Background CBG Communications,

More information

Selecting the right equalizer for an RF amplifier.

Selecting the right equalizer for an RF amplifier. Selecting the right equalizer for an RF amplifier. Frequencies bandwidth and amplifiers selected for CATV-FC systems. 1- On a modern FC-CATV system, there are 2 types of RF amplifiers MINI-BRIGER and INE

More information

CATV / OPTICAL / DOCSIS ANALYZERS CATV, OPTICAL & DOCSIS ANALYZERS www.promaxelectronics.com CABLE RANGER 3.1 CABLE RANGER 3.0 RANGER MINI RANGER MICRO Built-in DOCSIS 3.1 cable modem From 5 to 1800 MHz

More information

TRFM Series RF Amplifier Module

TRFM Series RF Amplifier Module Doc. 2272065, Rev. C TIARRA Optical Node TRFM Series RF Amplifier Module Contents Equipment Description... 39 Model Names... 41 Functional Description... 43 Return RF Signal Flow... 45 Controls and Connectors...

More information

CPON-HFC. Customer Premises Optical Node for FTTH networks. About the Product

CPON-HFC. Customer Premises Optical Node for FTTH networks. About the Product About the Product The Light Link Direct CPON-HFC customer premises optical node for FTTH networks offers full-bandwidth cable television delivery, plus broadband access via DOCSIS cable modems. Fibre-to-the-home

More information

! "#$ ' % & % & ' ( )!' *!+, ( *-"(! './ 0 / 0/ $ 1/ 2$3 1

! #$ ' % & % & ' ( )!' *!+, ( *-(! './ 0 / 0/ $ 1/ 2$3 1 ! "#$ ' %& %& ' ()!' *!+, (*- "(!'./0/0/ $1/2$3 1 1550 Fiber Transmitters 1550 nm External Modulation 4CHT8500AC (40~1GHz) 4CHT8500A 40~870 MHz) 1550nm External Modulation CATV Optic Transmitter Product

More information

Symmetrical Services Over HFC Networks. White Paper

Symmetrical Services Over HFC Networks. White Paper Symmetrical Services Over HFC Networks White Paper January 2003 Introduction In today s tough business climate, MSOs are seeking highly cost-effective solutions that allow them to squeeze every possible

More information

DS2460Q QAM Analysis Meter

DS2460Q QAM Analysis Meter DS2460Q QAM Analysis Meter Key Benefits Comprehensive tool for installation and maintenance of cable networks Fast spectrum analysis, 5~1220 MHz 5~1052MHz (Analog TV), 46~1052MHz (Digital TV) Digital TV

More information

Table of Contents. Amplifiers Broadband Telecommunications Line Extender [BLE-75**] FEATURES

Table of Contents. Amplifiers Broadband Telecommunications Line Extender [BLE-75**] FEATURES Table of Contents Amplifiers Broadband Telecommunications Line Extender [BLE-75**] FEATURES 750 MHz Power Doubling Technology 60/90 V Powering Surge Tolerant 29 db Operational Gain Bode Equalization (thermal

More information

TriAccess Solutions. Advanced CATV & High-Speed Data

TriAccess Solutions. Advanced CATV & High-Speed Data 2014 TriAccess Solutions TM Advanced CATV & High-Speed Data TriQuint s complete cable TV (CATV) and fiber to the home / premises (FTTH / FTTP) TriAccess product line is designed around the needs of high-speed

More information

THE FUTURE OF NARROWCAST INSERTION. White Paper

THE FUTURE OF NARROWCAST INSERTION. White Paper THE FUTURE OF NARROWCAST INSERTION White Paper May/2013 The future of narrowcast insertion Next generation, CCAP compliant RF combining This paper looks at the advantages of using the converged cable access

More information

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms RLT 1550 d10 DWDM High Power, Ultra Wide Band CATV & SAT 47-2.700 MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms The ultra wide band, 47-2.700 MHz, optical, laser transmitter,

More information

SYSTEM DESIGN - NEXT GENERATION HFC

SYSTEM DESIGN - NEXT GENERATION HFC SYSTEM DESIGN - NEXT GENERATION HFC July 26, 2016 Steve Harris, Senior Director Advanced Technologies & Instruction, L&D sharris@scte.org 2016 Society of Cable Telecommunications Engineers, Inc. All rights

More information

XCOM1002JE (8602JE) Optical Receiver Manual

XCOM1002JE (8602JE) Optical Receiver Manual XCOM1002JE (8602JE) Optical Receiver Manual - 2 - 1. Product Summary XCOM1002JE (8602JE) outdoor optical receiver is our latest 1GHz optical receiver. With wide range receiving optical power, high output

More information

Description. Features MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2.

Description. Features MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2. MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2 Description Features The Light LinkB B Series 2 Optical distribution node with two amplified RF ports (ODN2P) has been

More information

ADVANCED SYSTEM DESIGN PRODUCT SPECIFICATIONS

ADVANCED SYSTEM DESIGN PRODUCT SPECIFICATIONS FEATURES OF THE : G 750 MHz or 870 MHz Power Doubling Technology in Enhanced GaAs (E-GaAs) or Silicon G High Gain Versions G Six Diplex Filter Options including the latest M- split (80/108 MHz) G Improved

More information

2015 OPTICAL TRANSMITTERS

2015 OPTICAL TRANSMITTERS 2015 OPTICAL TRANSMITTERS Released V H Mar 15 SATELLITE AND TERRESTRIAL OPTICAL BROADCAST EQUIPMENT DVB is a registered trademark of the DVB Project A DVA NCE D TECHNOLOGY FOR PROFESSIONAL BROADCASTING

More information

Measurement of Television Channel Levels on CATV Networks

Measurement of Television Channel Levels on CATV Networks Measurement of Television Channel Levels on CATV Networks D E Woollard, SCTE Papers Committee Chairman 21st January 1999 1. Introduction Traditionally the measurement of Television channels has been concerned

More information

860 DSPi Multifunction Digital Analyzer

860 DSPi Multifunction Digital Analyzer ONLY Analyzer with an Optional Embedded CableLabs Certified DOCSIS 3.0 Modem DSP Technology Allows for Quick, Accurate Measurements Versatile Capabilities from Triple Play Signal Analysis for Installations

More information

Opti Max Nodes Digital Return System

Opti Max Nodes Digital Return System arris.com Opti Max Nodes Digital Return System 2x85 MHz Legacy ARRIS Protocol Node Transmitter and CHP Receiver FEATURES Digital Return technology for ease of set up and simplified plug and play operation

More information

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation Data Sheet Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation Description The Cisco Prisma II line of optical network transmission products is an advanced system designed

More information

REGIONAL NETWORKS FOR BROADBAND CABLE TELEVISION OPERATIONS

REGIONAL NETWORKS FOR BROADBAND CABLE TELEVISION OPERATIONS REGIONAL NETWORKS FOR BROADBAND CABLE TELEVISION OPERATIONS by Donald Raskin and Curtiss Smith ABSTRACT There is a clear trend toward regional aggregation of local cable television operations. Simultaneously,

More information

TCF: Hybrid fibre coax systems Online course specification

TCF: Hybrid fibre coax systems Online course specification TCF: Hybrid fibre coax systems Online course specification Course aim: By the end of this course trainees will be able to describe the operation, components and capabilities of hybrid fibre coax cable

More information

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1

More information

OPTILAB CATALOG TRANSMITTER OPTICAL NODE MINI-NODE EDFA PASSIVE OPTICS RECEIVER

OPTILAB CATALOG TRANSMITTER OPTICAL NODE MINI-NODE EDFA PASSIVE OPTICS RECEIVER OPTILAB CATALOG END-TO-END LASERS AND FIBER OPTIC PRODUCTS FOR RFOG, HFC, PON, DEEP FIBER 2013 Q3 OPTILAB CATALOG RUS & USDA ACCEPTED PRODUCTS VERSATILE AND EXCELLENT TRANSMISSION SOLUTIONS FOR HFC, RFOG,

More information

THE EFFECT OF LOOSE CONNECTORS ON SHIELDING EFFECTIVENESS

THE EFFECT OF LOOSE CONNECTORS ON SHIELDING EFFECTIVENESS THE EFFECT OF LOOSE CONNECTORS ON SHIELDING EFFECTIVENESS Asheridge Communications (A Teleste PLC Company) has undertaken a study to further understand the issues of RFI (Radio Frequency Interference)

More information

Juniper Networks G10 CMTS

Juniper Networks G10 CMTS Juniper Networks G10 CMTS Pre-Installation Guide Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, CA 94089 USA 408-745-2000 www.juniper.net Part Number: 530-008003-01, Revision 1 Copyright

More information

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1

More information

BALANCING THE REVERSE PATH

BALANCING THE REVERSE PATH BALANCING THE REVERSE PATH A good Reverse Path is essential for broadband delivery on a cable network. This article takes a closer look at the Reverse Path and provides tips on setting up the Reverse Path

More information

PROMAX NEWSLETTER Nº 22

PROMAX NEWSLETTER Nº 22 PROMAX NEWSLETTER Nº 22 TV EXPLORER HD series: H.264 / MPEG-4 AVC picture CV-100: Optical LNB adapter for TV EXPLORER MO-370: ISDB-T/T B modulator DIGITAL To TV: for Broadcast and TV Distribution PROMAX-27:

More information

1/31/2009. Technical highlights session PRODUCTS & SERVICES Summary. Sam Tagliavore PBN-FTTX

1/31/2009. Technical highlights session PRODUCTS & SERVICES Summary. Sam Tagliavore PBN-FTTX Technical highlights session PRODUCTS & SERVICES Summary Sam Tagliavore www.pbnamericas.com 1-877-PBN-FTTX 1 Fiber to the: Home Apartment Business Neighborhood No Broadband Bottlenecks One Platform One

More information

WDM Video Overlays on EFM Access Networks

WDM Video Overlays on EFM Access Networks WDM Video Overlays on EFM Access Networks David Piehler Harmonic, Inc. Broadband Access Networks IEEE 802.3ah January 2002 meeting Raleigh, North Carolina david.piehler@harmonicinc.com 1 Main points of

More information

Prisma D-PON System ONT and Upstream Receiver

Prisma D-PON System ONT and Upstream Receiver Prisma D-PON System ONT and Upstream Receiver The Cisco Prisma D-PON System is a fiber-to-the-home (FTTH) solution specifically designed for RF and DOCSIS based service providers. This system provides

More information

HDO701 FIBRE OPTIC TRANSMITTER

HDO701 FIBRE OPTIC TRANSMITTER Timo Rantanen 12.7.2011 1(5) HDO701 FIBRE OPTIC TRANSMITTER HDO701 is a high performance, extremely linear externally modulated 1550 nm transmitter for fibre optic CATV links. This transmitter type has

More information

CATV & DOCSIS3.0 Meter / Analyzer. Purchase from:

CATV & DOCSIS3.0 Meter / Analyzer. Purchase from: EN CATV & DOCSIS3.0 Meter / Analyzer Overview Introducing the H30. New from Televes, a go-to meter designed with the needs of a Cable TV operator in mind. The H30 is a light weight, rugged unit, packed

More information

Prisma D-PON System 1550 nm Downstream Transmitter and EDFA

Prisma D-PON System 1550 nm Downstream Transmitter and EDFA Prisma D-PON System 1550 nm Downstream Transmitter and EDFA The Prisma D-PON System is a fiber-to-the-home (FTTH) solution specifically designed for RF and DOCSIS-based service providers. This system provides

More information

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2) Optical Receiver Manual Transmitter OP-OR212JSE Shenzhen Optostar Optoelectronics Co., Ltd 2016. 7(Version 2) 1. Summary OP-OR212JSE optical receiver is the latest 1GHz dual-way switch optical receiver.

More information

Headend Optics Platform (CH3000)

Headend Optics Platform (CH3000) arris.com Headend Optics Platform (CH3000) HT3540H Series Double-Density Full Spectrum DWDM Transmitter System FEATURES DWDM transmitter: up to 40 wavelengths on ITU grid Hot plug in/out, individually

More information

Impacts on Cable HFC Networks

Impacts on Cable HFC Networks Copyright 2014, Technology Futures, Inc. 1 Impacts on Cable HFC Networks Robert W Harris Senior Consultant, Technology Futures, Inc. rharris@tfi.com TFI Communications Technology Asset Valuation Conference

More information

CHP Max Headend Optics Platform CHP CORWave II

CHP Max Headend Optics Platform CHP CORWave II CHP Max Headend Optics Platform CHP CORWave II 1 GHz C Band DWDM Forward Transmitters FEATURES Consolidation or elimination of OTNs and node splitting by harvesting plant assets with up to 16 full spectrum

More information

Radio Frequency over Glass. Passive Optical Network (PON) for EuroDOCSIS infrastructures

Radio Frequency over Glass. Passive Optical Network (PON) for EuroDOCSIS infrastructures Radio Frequency over Glass Passive Optical Network (PON) for EuroDOCSIS infrastructures Radio Frequency over Glass (RFoG) Because RFoG extends the range of glass-fibre networks to buildings (FttB) and

More information

Prisma Optical Networks Ancillary Modules

Prisma Optical Networks Ancillary Modules Optoelectronics Prisma Optical Networks Ancillary Modules Description The Prisma platform is capable of utilizing a combination of modules which address a variety of revenue generating applications. The

More information

DROP HARDENING. January 21, 2015

DROP HARDENING. January 21, 2015 DROP HARDENING January 21, 2015 SCTE LIVE LEARNING Monthly Professional Development service Generally Hot Topics or Topics of high interest to the industry Vendor Agnostic No product promotion Free to

More information

384A Adapter Installation Instructions

384A Adapter Installation Instructions Instruction Sheet 860237684 Issue 9, October 2012 SYSTIMAX Solutions 384A Adapter Installation Instructions General The 384A adapter (Figure 1) is a broadband video adapter that provides connectivity to

More information

High Density Optical Platform for FTTx and HFC

High Density Optical Platform for FTTx and HFC High Density Optical Platform for FTTx and HFC Optical Platform for FTTx and HFC The WISI optical platform Optopus is a highly flexible and high density platform for all kinds of analog optical networks.

More information

FORWARD PATH TRANSMITTERS

FORWARD PATH TRANSMITTERS CHP Max FORWARD PATH TRANSMITTERS CHP Max5000 Converged Headend Platform Unlock narrowcast bandwidth for provision of advanced services Economical and full-featured versions Low profile footprint allows

More information

DOCSIS 3.1 roll Out First Lessons Learned DOCSIS 3.1 roll Out First Lessons Learned

DOCSIS 3.1 roll Out First Lessons Learned DOCSIS 3.1 roll Out First Lessons Learned DOCSIS 3.1 roll Out First Lessons Learned DOCSIS 3.1 roll Out First Lessons Learned Pay utmost attention to noise, and how to eliminate it Avoid cold-flow phenomena Terminate DOCSIS service in the first

More information

Viavi ONX Ingress Mitigation and Troubleshooting Field Use Case using Ingress Expert

Viavi ONX Ingress Mitigation and Troubleshooting Field Use Case using Ingress Expert Viavi ONX Ingress Mitigation and Troubleshooting Field Use Case using Ingress Expert February 2018 Contents Purpose:... 2 Procedure:... 2 Real World Application and Use Case Findings:... 2 Consistent Noise

More information

RSS-2T RF Broadband Automatic Switching Station

RSS-2T RF Broadband Automatic Switching Station RSS-2T RF Broadband Automatic Switching Station The RSS-2T is designed for the redundancy of analog RF channels, QAM RF channels, and CATV RF- Broadband feeds in Headend and Hub sites. The RSS automatic

More information

Cisco 1.25 GHz Surge-Gap Passives

Cisco 1.25 GHz Surge-Gap Passives Data Sheet Cisco 1.25 GHz Surge-Gap Passives The Cisco 1.2 GHz Surge-Gap Passives product line is the latest evolution of the HFC network providing full support of the DOCSIS 3.1 standard. DOSCIS 3.1 support

More information

FCC Required Technical Standards for Analog & Digital Signals

FCC Required Technical Standards for Analog & Digital Signals FCC Required Technical Standards for Analog & Digital Signals Robert Schaeffer, President Technology Planners, LLC robert.schaeffer@techplanners.com SCTE IEEE Senior Consultant to NCTC Cable TV Pioneers

More information

PROMAX NEWSLETTER Nº 25. Ready to unveil it?

PROMAX NEWSLETTER Nº 25. Ready to unveil it? PROMAX NEWSLETTER Nº 25 Ready to unveil it? HD RANGER Evolution? No. Revolution! PROMAX-37: DOCSIS / EuroDOCSIS 3.0 Analyser DVB-C2 now available for TV EXPLORER HD+ C-band spectrum analyser option for

More information

Section 167. Depreciation

Section 167. Depreciation Section 167. Depreciation 26 CFR 1.167(a) 11: Depreciation based on class lives and asset depreciation ranges for property placed in service after December 31, 1970. Section 168. Accelerated Cost Recovery

More information

Model DM8000-U Optical Transmitter Direct Modulation, DWDM, Low Distortion, Wideband

Model DM8000-U Optical Transmitter Direct Modulation, DWDM, Low Distortion, Wideband Model DM8000U Optical Transmitter Direct Modulation, DWDM, Low Distortion, Wideband Applications Video signal distribution to HFC CATV and FTTP nodes 1527 Supports CATV, QAM, and DBS signal carriage Replacement

More information

CABLE TV on fiber. CABLE TV FIBERLINK Pass 100+ TV channels on 1 SingleMode fiber with no need for amps

CABLE TV on fiber. CABLE TV FIBERLINK Pass 100+ TV channels on 1 SingleMode fiber with no need for amps #FBS-870R-WALL-econ Reasonable prices, priceless reasoning. CABLE TV on fiber CABLE TV FIBERLINK Pass 100+ TV channels on 1 fiber with no need for amps Combine dozens of analog and digital channels in

More information

OmniStar GX2 Headend Optics Platform

OmniStar GX2 Headend Optics Platform arris.com OmniStar GX2 Headend Optics Platform GX2 RX200BX4 Quad Return Path Receiver FEATURES Very high module density allowing up to 16 quad receiver modules in a housing to provide 64 independent optical

More information

Hands-On Real Time HD and 3D IPTV Encoding and Distribution over RF and Optical Fiber

Hands-On Real Time HD and 3D IPTV Encoding and Distribution over RF and Optical Fiber Hands-On Encoding and Distribution over RF and Optical Fiber Course Description This course provides systems engineers and integrators with a technical understanding of current state of the art technology

More information

Table of Contents. Headend Optical Transport OmniStar Enhanced DFB Laser [AM-OMNI-ALM-*] file:////ncs-server-xp/temp/motorola CD 2001/frames.

Table of Contents. Headend Optical Transport OmniStar Enhanced DFB Laser [AM-OMNI-ALM-*] file:////ncs-server-xp/temp/motorola CD 2001/frames. Table of Contents Headend Optical Transport OmniStar Enhanced DFB Laser [AM-OMNI-*] file:////ncs-server-xp/temp/motorola CD 2001/frames.htm (1 of 5) [7/8/2009 8:23:40 AM] FEATURES 870 MHz passband: up

More information

MODULO - HFC YOUR SMART HFC HEADEND TOOLKIT UNIVERSAL, SMART AND EASY - DON T MISS IT THE ART OF ENGINEERING

MODULO - HFC YOUR SMART HFC HEADEND TOOLKIT UNIVERSAL, SMART AND EASY - DON T MISS IT THE ART OF ENGINEERING YOUR SMART HFC HEADEND TOOLKIT UNIVERSAL, SMART AND EASY - DON T MISS IT UNIVERSAL, SMART, AND EASY Cable Operators are faced with the critical challenge of significantly increasing the efficiency and capacity

More information

Model 755U Optical Transmitter DWDM, up to 20 km, Low Distortion, Wideband

Model 755U Optical Transmitter DWDM, up to 20 km, Low Distortion, Wideband Model 755U Optical Transmitter DWDM, up to 20 km, Low Distortion, Wideband Emcore s Model 755U is a directly modulated (DM) DWDM optical transmitter specifically designed for wideband applications that

More information

TEPZZ 889A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2017/35

TEPZZ 889A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2017/35 (19) TEPZZ 889A_T (11) EP 3 211 889 A1 (12) EUROPEAN PATENT APPLICATION (43) Date of publication:.08.17 Bulletin 17/3 (21) Application number: 163970. (22) Date of filing: 26.02.16 (1) Int Cl.: H04N 7/

More information

The 1.2 GHz NCI solution from Technetix:

The 1.2 GHz NCI solution from Technetix: The 1.2 GHz NCI solution from Technetix: The future of headend RF signal management The demand for high speed Internet and digital television means that headends are frequently modified, extended and upgraded

More information

DOCSIS 3.1 Operational Integration and Proactive Network Maintenance Tools

DOCSIS 3.1 Operational Integration and Proactive Network Maintenance Tools DOCSIS 3.1 Operational Integration and Proactive Network Maintenance Tools Enhancing Network Performance Through Intelligent Data Mining and Software Algorithm Execution (aka More with Less!) A Technical

More information

MULTIDYNE Electronics, Inc. Innovations in Television Testing & distribution

MULTIDYNE Electronics, Inc. Innovations in Television Testing & distribution INSTRUCTION MANUAL DVM-2200 DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM MULTIDYNE Electronics, Inc. Innovations in Television Testing & distribution 1-(800)-4TV-TEST, 1-(800)-488-8378

More information

NCTA Technical Papers

NCTA Technical Papers EXPANDED BANDWIDTH REQUIREMENTS IN CATV APPLICATIONS DANIEL M. MOLONEY DIRECTOR, SUBSCRIBERMARKETING JOHN SCHILLING DIRECTOR, RESIDENTIAL EQUIPMENT ENGINEERING DANIELMARZ SENIOR STAFF ENGINEER JERROLD

More information

Multiple Band Outdoor Block Up- and Downconverters

Multiple Band Outdoor Block Up- and Downconverters Multiple Band Outdoor Block Up- and Downconverters Vertical Mount Option RF IF LO Frequency Frequency Frequency Model Band (GHz) (MHz) (GHz) Number Block Upconverters 1 12.75 13.25 0.95 1.45 11.8 UPB2-WS-13.625

More information

OmniStar GX2 Headend Optics Platform

OmniStar GX2 Headend Optics Platform arris.com OmniStar GX2 Headend Optics Platform GX2 EM1000 Series 1550 nm Broadcast Transmitter FEATURES Provides full performance 50 1002 MHz forward bandwidth for mixed analog and digital loading Versions

More information

DVX. Digital Versatile Headend

DVX. Digital Versatile Headend DVX Digital Versatile Headend TELESTE ACCESS SYSTEMS HEADEND PRODUCTS DVX Digital Versatile Headend - The Platform for Digital Age Overview Cable operators today are heavily affected by globalisation,

More information

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2) Optical Receiver Manual Transmitter OP-OR112R JⅢ Shenzhen Optostar Optoelectronics Co., Ltd 2016. 7(Version 2) 1. Summary OP-OR112RJⅢ optical receiver is our latest 1GHz FTTB optical receiver. With wide

More information

DQT1000 MODEL DIGITAL TO QAM TRANSCODER WITH DIGITAL PROCESSING AND MULTIPLEXING

DQT1000 MODEL DIGITAL TO QAM TRANSCODER WITH DIGITAL PROCESSING AND MULTIPLEXING MODEL DQT1000 DIGITAL TO QAM TRANSCODER WITH DIGITAL PROCESSING AND MULTIPLEXING The R. L. Drake model DQT1000 is a professional quality, digital headend transcoder product that tunes and demodulates MPEG2

More information

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split Data Sheet Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 MHz Split The Cisco GS7000 High-Output Segmentable Node with 42/54 MHz Split is the latest-generation 1-GHz optical node platform designed

More information

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video

More information

Cisco GS7000 High-Output (GaN) 4-Way Segmentable Node with 85/102 MHz Split

Cisco GS7000 High-Output (GaN) 4-Way Segmentable Node with 85/102 MHz Split Data Sheet Cisco GS7000 High-Output (GaN) 4-Way Segmentable Node with 85/102 MHz Split Consumer bandwidth demand continues to grow at a rapid rate every year. As a result, cable operators with DOCSIS-based

More information

White Paper. Performance analysis: DOCSIS 3.1 cable TV headend combining systems

White Paper. Performance analysis: DOCSIS 3.1 cable TV headend combining systems Performance analysis: DOCSIS 3.1 cable TV headend combining systems Measuring MER performance of QAM signals in passive & active combining systems White Paper Practical splitter performance Introduction

More information

Fibre Optics for cable TV

Fibre Optics for cable TV for cable TV Triax fibre optic solutions take your CATV network to the next level your ultimate connection Triax Fibre Network Equipment Structure of Fibre Optic Networks for Cable TV Systems + The fibre

More information

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL DVM-1000 DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM MULTIDYNE Electronics, Inc. Innovations in Television

More information

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment

More information

TriAccessTM. Solutions for Advanced CATV & High-Speed Data

TriAccessTM. Solutions for Advanced CATV & High-Speed Data TriAccessTM Solutions for Advanced CATV & igh-speed Data TriQuint s complete cable TV (CATV) and Fiber to the ome (FTT) TriAccess product line is designed around the needs of high-speed broadband service

More information

Typical applications:

Typical applications: Typical applications: Managing multiple inputs for growing satellite teleports Extended L-band frequency for Ka-band & HTS applications Routing live traffic to multiple modems ETL s new ultra compact Hurricane

More information

Directional Couplers and Splitters

Directional Couplers and Splitters Directional couplers and splitters divide trunk and feeder lines. 17-Amp current handling capacity. Excellent hum-modulation performance. 1/2-inch hard-line ports have extra length, creating a better seal

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 132 2012 Test Method For Reverse Path (Upstream) Bit Error Rate NOTICE The Society of Cable Telecommunications

More information

Broadcast and Satellite Communications

Broadcast and Satellite Communications POCKET GUIDE Integrated RF Solutions for Signal Distribution Broadcast and Satellite Communications Broadband HFC and FTTx Networks THE ART OF ENGINEERING List of Abbreviations AC APC ASI CATV CCAP CMTS

More information

Optical Communications Mainframe - Laser Transmitter Module

Optical Communications Mainframe - Laser Transmitter Module About the Product The LTM13 Multi Quantum Well (MQW) Distributed Feedback (DFB) laser transmitter module has been designed for cable television and HFC broadband applications. The LTM13 module easily fits

More information

H5000 Outdoor Mini Virtual HUB

H5000 Outdoor Mini Virtual HUB H5000 Outdoor Mini Virtual HUB The H5000 is an RFOG Indoor/Outdoor Mini Virtual Hub that provides an optical distribution point for downstream traffic and an aggregation point for upstream traffic, making

More information

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas / This Specification Data Sheet brought to you by: 15825 Trinity Blvd. Fort Worth, Texas 76155 817/465-9494 equipment@technicaldiagnostic.com www.technicaldiagnostic.com www.test-equipment-rental.com The

More information

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber MX/HD-SDI-3G Transmit HD-SDI-3G signals over Fiber Key Features Transmit ASI or SDI signal over one single-mode Fiber Support data rate from 19.4Mb/s to 3Gb/s SMPTE 424M, SMPTE 292M, SMPTE 344M and SMPTE

More information

WHITE PAPER. Comprehensive Node Analysis Assures Big Upstream Gains For DOCSIS 3.0 Channel Bonding

WHITE PAPER. Comprehensive Node Analysis Assures Big Upstream Gains For DOCSIS 3.0 Channel Bonding WHITE PAPER Comprehensive Node Analysis Assures Big Upstream Gains For DOCSIS 3.0 Channel Bonding Comprehensive Node Analysis Assures Big Upstream Gains For DOCSIS 3.0 Channel Bonding Overview As MSOs

More information

PROMAX NEWSLETTER Nº 18

PROMAX NEWSLETTER Nº 18 PROMAX NEWSLETTER Nº 18 TV EXPLORER HD: H.264 / MPEG-4 AVC picture PROMAX-27: Cable TV analyser with IPTV & VoIP QoS TV HUNTER: Aligning antennas, quickly and easily PROLITE-75: FTTx Analyser for deployment

More information

Model GS Port Node 1 GHz with 65/86 MHz split

Model GS Port Node 1 GHz with 65/86 MHz split Model GS7000 4-Port Node 1 GHz with 65/86 MHz split The Model GS7000 4-Port Node is our latest generation 1 GHz optical node platform and utilizes a completely new housing designed for optimal heat dissipation.

More information

Forward Sweep and Balance

Forward Sweep and Balance Forward Sweep and Balance Application Note 1 CATV Application: Using WWG s family of StealthSweep for forward sweep and balance. Step-by-Step Headend Set-up Set-up of Forward Sweep (see diaram below) A

More information