BOTC-TEG-8500 Example Transport Engineering Guide (TEG): Video Products Group Inc (VPG) Ventura Broadcast Video -48VDC applications

Size: px
Start display at page:

Download "BOTC-TEG-8500 Example Transport Engineering Guide (TEG): Video Products Group Inc (VPG) Ventura Broadcast Video -48VDC applications"

Transcription

1 Example Transport Engineering Guide (TEG): Video Products Group Inc (VPG) Ventura Broadcast Video -48VDC applications Section Table of Contents Page DS Data Sheet (weight, footprint, power, heat, timing, alarms/rm, DF blocks, CLEI) 2 1 Overview 3 2 Equipment requirements 4 3 Relay rack layout 5 4 System connection details 6-10 Issue Revisions Date 1 Original release of Bill Oakes Engineering Guide for VPG Ventura July 15, Revise into Word format. October 23, 2007 Acronyms: American Wire Gauge (AWG), Battery Distribution Fuse Board (BDFB), Central Office (CO), Digital Cross connect System-electronic (DCS), Digital System Cross connect-manual (DSX), Distributing Frame (DF), Enclosed Network Extension-RT/CEV/Hut/Prem (ENE), Fiber Distribution Frame (FDF), National Television Systems Committee (NTSC), Network Element (NE), Receive (RX), Serial Digital Interface (SDI), Simple Network Management Protocol (SNMP), Society of Motion Picture and Television Engineers (SMPTE), Support Engineering Guide (SEG), Transmit (TX), Video Products Group Inc (VPG). Bill Oakes Telecom Consultants (BOTC) bill.oakes@att.net, Copyright All rights reserved. 1

2 Data Sheet: The preface section of all BOTC-TEGs is a data sheet that provides quick view information for weight, relay rack footprint, peak (LIST 2)/nominal (LIST 1) power amperage, heat dissipation wattage, timing, alarms/remote management, DF block and CLEI code requirements. The data shown is an ultimate condition (relay rack fully loaded with equipment as designed in associated BOTC-TEG). Even though many relay rack deployments are partially equipped, BOTC recommends basing initial space/engineering planning on ultimate data since existing rack layouts typically grow to conclusion without follow-up involvement by planning personnel. Category Weight Footprint Peak/LIST 2 amperage at 42.6V Nominal/LIST 1 amperage at 52V Heat dissipation Timing (BITS) Alarms Remote management DF blocks CLEI codes (see BOTC-SEG-0600 section 4) Requirement 362 pounds 26" wide x 15" deep amps 14.8 amps 688 watts N/A See remarks 8 Ethernet SNMP N/A PWFYAL1CAA VPM3DD0CRA Data sheet for VPG Ventura relay rack Remarks One relay rack: 120 pounds. One fuse panel: 10 pounds. Eight fully equipped Ventura VS103 shelves (29 pounds each): 232 pounds. 26" wide rack. 5" deep front and rear guard boxes. Eight Ventura VS103 shelves at 2.82 amps each. Eight Ventura VS103 shelves at 1.85 amps each. Eight Ventura VS103 shelves at 86 watts each. No timing requirement for VPG Ventura racks. 1 status point required on CO alarm system for rack fuse panel alarm. Each Ventura VS103 shelf has 24 discrete alarms but connection is not required if Ethernet remote management is used (alarms integrated into signal). 1 Ethernet SNMP for each Ventura VS103 shelf if equipped with VS183 network management card. No DF connection for VPG Ventura racks. Telect 0HPGMT05R fuse panel. Ventura VS103 shelf. 2

3 1. Overview: Broadcast Video equipment transports wholesale customer signal content through a Service Provider/Telco network for eventual handoff at that same wholesale level. For example, the origination of nationwide/local TV programming routes to the nearest Service Provider/Telco CO or ENE. Signals are then transported to a cable TV company (wholesale handoff at interface point) who bundles the service into channel packages for resale to customers (individual homes) at the retail level. Many Service Providers/Telcos are now building their own Retail Video service network. In this case, Broadcast Video equipment is still used to collect and transport nationwide/local TV programming but the signals hand off to Retail Video systems within the Service Provider/Telco network. For Retail Video examples, see the overview section of BOTC-TEG-1150 (Alcatel 7330 Fiber To The Node) and BOTC-TEG-1160 (Alcatel 7342 Fiber To The Prem or User). VPG ( Ventura is a digital Broadcast Video fiber transport system. VS103-DC shelves have 12 slots that are designated (reading left to right as viewed from front) PSU1, PSU2, Slot 1 to 10. PSU1 and 2 are used for redundant power supply modules. Slot 1 is normally reserved for a Network Management card (permanent basis if cabled per section 4 part D or temporary basis for occasional field maintenance routines). TX and RX modules mount in Slots 2 to 10 and can be configured for service type A or B below. A) Using VS551 module: National Television Systems Committee (NTSC) analog TV1 service. Drop side is one 6 MHz video channel and 0, 2 or 4 associated audio circuits (15 or 20 KHz each). As with most analog systems in the industry, separate cabling is used for electrical video and audio to maintain good dynamic sound quality. See Telcordia GR-338-CORE for additional details. B) Using VS201, VS231, VS411 modules: Society of Motion Picture and Television Engineers (SMPTE) 259M Serial Digital Interface (SDI) 270 Mb/s service. Drop side circuits are 270 Mb/s combined audio/video channels. VS201 and VS231 TX or RX modules are 270 Mb/s on both sides (line side fiber, drop side coax). VS411 TX or RX modules are Gb/s on the line (fiber) side with four sets of 270 Mb/s coax on the drop side. VS551 encoder and decoder modules are 270 Mb/s on the line side (can be fiber or coax but not both on the same module) and analog TV1 audio/video on the drop side. VS201, VS231 and VS551 modules also have a second output on the drop (coax) side that may connect to a TV service monitor room in some COs. Fiber, coax and audio cables terminate on the rear of each module (not on the shelf backplane). Audio/video circuits can be cabled to special audio/video cross connect patch panels or directly to other video equipment (hardwire). Prior to engineering Broadcast Video jobs, vendors should consult with Service Provider/Telco personnel about the connection method between systems. Broadcast Video equipment should not be connected to DSX or DCS due to it s unique signal format. See BOTC-SEG-0100 section 13 for NTSC TV1 audio cable methods. See BOTC-SEG-0200 section 7 for SMPTE SDI audio/video and NTSC TV1 video coax methods. 3

4 2. Equipment requirements: This section provides part number and mounting/usage details for equipment in VPG Ventura relay racks. See section 3 figure 3 for assembly details. Plug-ins are listed here but they may be ordered separately via Service Provider/Telco Plug-in Inventory Control System (PICS) routines. Any combination of Part H to T modules can be used in Slots 2 to 10 but the overall sum total of modules is limited to nine per shelf. A) Relay rack: One 7 Network rack with 1.75 x 23 drilling and 5 front welded guard box. See BOTC-SEG B) Rear guard box: One 5 rear field mount guard box must be ordered as a separate item so that the footprint depth is 15 (5 front, 5 rear). See BOTC-SEG C) Fuse panel: One Telect 0HPGMT05R high. See BOTC-SEG D) Ventura shelf: VPG part number VS103-DC provides one 12 slot shelf for -48VDC applications. E) Heat baffle: VPG part number VS111. One required above each. F) -48VDC power supply module (PICS item?): VPG part number VS123. Two required for each. G) Network Management card (PICS item?): VPG part number VS183. One required for each if section 4 part D Ethernet remote management cabling is run. H) 1310nm single channel SMPTE SDI TX module with clock recovery (PICS item?): VPG part number VS EO. J) 1550nm single channel SMPTE SDI TX module with clock recovery (PICS item?): VPG part number VS EO-S. K) Single channel SMPTE SDI RX module with clock recovery (PICS item?): VPG part number VS201-OE. L) 1310nm single channel SMPTE SDI TX module with jitter management (PICS item?): VPG part number VS EO. M) 1550nm single channel SMPTE SDI TX module with jitter management (PICS item?): VPG part number VS EO-S. N) Single channel SMPTE SDI RX module with jitter management (PICS item?): VPG part number VS231-OE. P) 1310nm four channel SMPTE SDI TX module (PICS item?): VPG part number VS EO. Q) 1550nm four channel SMPTE SDI TX module (PICS item?): VPG part number VS EO-S. R) Four channel SMPTE SDI RX module (PICS item?): VPG part number VS411-OE-32. S) Single channel NTSC TV1 encoder module (PICS item?): VPG part number VS551-ADC-SFP. Requires one separately ordered SFP TX module (part U or V) if line side is optic. T) Single channel NTSC TV1 decoder module (PICS item?): VPG part number VS551-DAC-SFP. Requires one separately ordered SFP RX module (part W) if line side is optic. U) 1310nm SFP TX module for VS551-ADC-SFP module (PICS item?): VPG part number SFP-TV-1310-S. V) 1550nm SFP TX module for VS551-ADC-SFP module (PICS item?): VPG part number SFP-TV-1550-S. W) SFP RX module for VS551-DAC-SFP module (PICS item?): VPG part number SFP-RV-PIN. X) Blank panel for slots: VPG part number To maintain proper ventilation, two blank panels (one on front and one on rear) are required for each for any unequipped Slot 1 to 10 position on shelf. AA) Optional combined audio/video patch panel: Not required if video systems are hardwired. See part AB and AC if separate audio and video patch panels are used. Bittree part number SBCIPS01 provides patch panel with 16 video jack circuits (1 to 8 upper, 1 to 8 lower) and 64 audio jack circuits (1A to 8D upper, 1A to 8D lower). Cross connects are internally hardwired (video 1 upper to video 1 lower, audio 1A upper to audio 1A lower, etc). AB) Optional audio patch panel: Not required if video systems are hardwired. See part AA if combined audio/video patch panel is used. ADC part number PPS3-14MKIIHN provides patch panel with 48 audio jack circuits (1 to 24 upper, 25 to 48 lower). Cross connects are internally hardwired (1 to 25, 2 to 26, etc). AC) Optional video patch panel: Not required if video systems are hardwired. See part AA if combined audio/video patch panel is used. ADC part number PPI2232RS-MVJ provides patch panel with 64 video jack circuits (1 to 32 upper, 33 to 64 lower). Cross connects are internally hardwired (1 to 33, 2 to 34, etc). 4

5 3. Relay rack layout: BOTC-TEG-8500 BV or 43 Fuse panel BU or 42 VS111 heat baffle BT or 41 BS or 40 BR or 39 8 INSTALLATION: BQ or 38 VS111 heat baffle BP or 37 BN or 36 BM or 35 7 BL or 34 VS111 heat baffle BK or 33 BJ or 32 BH or 31 6 BG or 30 VS111 heat baffle BF or 29 BE or 28 BD or 27 5 BC or 26 BB or 25 BA or 24 V or 23 Area for optional U or 22 audio/video patch panels T or 21 S or 20 R or 19 Q or 18 P or 17 VS111 heat baffle N or 16 M or 15 L or 14 4 K or 13 VS111 heat baffle J or 12 H or 11 G or 10 3 F or 9 VS111 heat baffle E or 8 D or 7 C or 6 2 B or 5 VS111 heat baffle A or 4 AA or 3 AB or 2 1 AC or 1 AD or x VS103-DC shelves are 5.25" high, 19" wide and 14" deep. 19" to 23" rack adapters and 5" front stand-offs must be provided by you. 2. VS111 heat baffles are 1.75" high, 19" wide and 14" deep. 19" to 23" rack adapters and 5" front stand-offs must be provided by you. 3. Each of the optional patch panels needs 19" to 23" rack adapters and 5" front standoffs that must be provided by you. 4. ADC PPS3-14HKIIHN audio patch panels are 3.5" high, 14" deep and 19" wide. 5. ADC PPI2232RS-MVJ video patch panels are 3.5" high, 9" deep and 19" wide. 6. Bittree SBCIPS01 audio/video patch panels are 3.5" high, 12.5" deep and 19" wide. FIGURE 3 Layout for VPG Ventura VS103-DC shelves. Provide rear side 2" x 2" vertical fiber protection duct on right upright (as viewed from rear of rack) down to shelf 1 level. 5

6 4. System connection details: A) Fuse panel: Step 1 (Dual redundant load input feeders from BDFB): See BOTC-SEG-0500 section 11 for BDFB fuse/feeder sizing responsibility and BOTC-SEG-0700 section 9 for wire material. Provide 4 two hole lugs (.25 studs on.625 centers) for input feeder connections (wire size determined by vendor based on job conditions). Total LIST 2 for eight shelf rack is amps. Step 2 (Chassis ground): Provide 1 two hole lug (No.10 studs on.625 centers) for 6 AWG wire. Connect lug to relay rack ground using 6 AWG wire (see BOTC-SEG-0700 section 7 and 9). Step 3 (Alarms): Run 24 AWG Black and Red-Black wire pair (see BOTC-SEG-0700 section 8) from fuse panel R set NO/C wire wrap pins to CO alarm system (Dantel for example) status point. No connection for V and A set pins. B) Power for : Step 1 (intra-rack wiring): Connect DC IN 1 (-48V), + (Return) and DC IN 2 (-48V), + (Return) symbol screws to fuse panel output positions using 20 AWG Black/Red-Black wire pairs (see BOTC-SEG-0700 section 8). Use Red-Black lead for -48V and Black lead for RETURN. Provide Thomas & Betts (or generic equivalent) RA18-6 ring terminals for shelf end and RA484 ring terminals for fuse panel end. Step 2 (fuse panel fuses and designation pins): Maximum drain is 2.82 amp. Fuse externally at 5 amp. See BOTC-SEG-0500 section 14 for GMT fuse and designation pin part numbers. C) Chassis ground for : Step 1 (intra-rack wiring): Connect GND screw to relay rack ground using spare 20 AWG Black wire from part B. Provide Thomas & Betts (or generic equivalent) RA18-6 ring terminal for shelf end. No connection required for ESD screw since internally common with GND screw. D) Remote management (only required if Slot 1 equipped with VS183 card): Step 1 (mount ribbon cable): VS183 card (section 2 part G) includes one short ribbon cable. Mount this ribbon cable between the ALARM DB50 connector and VS183 card J1/J2 50 pin connector. Step 2 (external remote management cable): Run electrical Ethernet cable with straight pinning (see BOTC- SEG-0100 section 10) from Slot 1 VS183 card J3 RJ45 connector (10BASE-T SNMP, pin 1 is TX+, pin 2 TX-, pin 3 RX+, pin 6 RX-) to the CO Remote management Ethernet hub equipment. E) Alarms for : This connection is not required if part D Ethernet remote management is used (alarms are integrated into signal). The ALARM connector is a DB50 female. 24 of the DB50 pins are used for discrete alarms (step 1). Pins (Slot 1 IC CLK, MJ, IC DATA, MN) are not used since Slot 1 is reserved for a Network Management card (instead of TX or RX module). Pins 2-17, 34, 35, 38, 39, 47, 49 (Slot 2 to 10 IC CLK, IC DATA) are not used since these indications do not interface properly with external alarm system status points (but they are integrated into the part D Ethernet signal). Step 1 (field form alarm connector): Provide one Cinch DDU-50P Crimp and Poke DB50 male connector and two Cinch D screw lock assemblies (or generic equivalent). Provide 12 pair 24 AWG unshielded alarm cable (see 200A series in BOTC-SEG-0100 section 14). Form cable leads onto DDU-50P connector pins as follows: Pin 1: FAN MJ, Pin 18: Slot 10 MN, Pin 19: Slot 10 MJ, Pin 20: Slot 9 MN, Pin 21: Slot 9 MJ, Pin 22: Slot 8 MN, Pin 23: Slot 8 MJ, Pin 24: Slot 7 MN, Pin 25: Slot 7 MJ, Pin 26: Slot 6 MN, Pin 27: Slot 6 MJ, Pin 28: Slot 5 MN, Pin 29: Slot 5 MJ, Pin 30: Slot 4 MN, Pin 31: Slot 4 MJ, Pin 32: Slot 3 MN, Pin 33: Slot 3 MJ, Pin 36: PS1 FAIL MJ, Pin 37: PSI DEG MN, Pin 40: PS2 FAIL MJ, Pin 41: PS2 DEG MN, Pin 42: FAN MN, Pin 48: Slot 2 MJ, Pin 50: Slot 2 MN. Step 2 (run alarm cable): Run Step 1 alarm cable from shelf ALARM connector to CO alarm system (Dantel for example) status points (requires 24 assignments). 6

7 F) Fiber for VS201, VS231, VS411 or VS551 modules on : The can have up to nine modules with a single fiber conductor on the line side. VS201, VS231 and VS551 modules are 270 Mb/s. VS411 modules are Gb/s. The signal direction is TX if module is electrical to optical (-EO suffix on VS201, VS231 or VS411 module part number) or an encoder (VS551-ADC-SFP). The signal direction is RX if module is optical to electrical (-OE suffix on VS201, VS231 or VS411 module part number) or a decoder (VS551-DAC-SFP). The line side on VS551 modules can be fiber or coax (part K) but not both on the same module. Step 1 (mount SFP, VS551 only): If module is VS551, mount SFP provided in section 2 part U, V or W. Step 2 (run fiber conductors): Use optical port (SC connector) on module (if VS201, VS231 or VS411) or SC SFP (if VS551). Run one TX or RX fiber conductor (see BOTC-SEG-0400) from each module to the FDF. Per section 3 figure 3, vertical duct material should be provided on rear side of right (as viewed from rear of rack) upright. G) SDI 270 Mb/s audio/video coax for VS201 modules on : The can have up to nine VS201 modules with one or two 270 Mb/s coax conductors on the drop side. The drop side coax signal direction is TX if module is optical to electrical (-OE suffix on module part number) or RX if module is electrical to optical (-EO suffix on module part number). Step 1 (consult with Service Provider/Telco about connection method): Audio/video coax circuits can be cabled to special audio/video cross connect patch panels or directly to other video equipment (hardwire). Prior to systems. Broadcast Video equipment should not be connected to DSX-3 or DCS due to it s unique signal format. Step 2 (consult with Service Provider/Telco about TV service monitor room): VS201 coax TX modules (-OE suffix on module part number) have a second output on the drop (coax) side that may connect to a TV service monitor room in some COs. Prior to engineering, vendors must consult with Service Provider/Telco personnel about the need for this connection. Step 3 (run coax conductors): Use VS201 module SDI 1 J1 port (regular signal) and optional SDI 2 J2 port (if also running to TV service monitor room). Provide one or two 90 degree BNC connectors for each module. Run one or two TX or RX coax conductors from each module to video patch panel (see part N or P) or other video equipment (hardwire with roll of TX to RX or RX to TX). See BOTC-SEG-0200 section 7 for BNC and coax material. H) SDI 270 Mb/s audio/video coax for VS231 modules on : The can have up to nine VS231 modules with one or two 270 Mb/s coax conductors on the drop side. The drop side coax signal direction is TX if module is optical to electrical (-OE suffix on module part number) or RX if module is electrical to optical (-EO suffix on module part number). Step 1 (consult with Service Provider/Telco about connection method): Audio/video coax circuits can be cabled to special audio/video cross connect patch panels or directly to other video equipment (hardwire). Prior to systems. Broadcast Video equipment should not be connected to DSX-3 or DCS due to it s unique signal format. Step 2 (consult with Service Provider/Telco about TV service monitor room): VS231 coax TX modules (-OE suffix on module part number) have a second output on the drop (coax) side that may connect to a TV service monitor room in some COs. Prior to engineering, vendors must consult with Service Provider/Telco personnel about the need for this connection. Step 3 (run coax conductors): Use VS231 module SDI IN J3 port (regular RX signal) or SDI OUT1 J5 port (regular TX signal) and optional SDI OUT2 J4 port (if also running to TV service monitor room). Provide one or two 90 degree BNC connectors for each module. Run one or two TX or RX coax conductors from each module to video patch panel (see part N or P) or other video equipment (hardwire with roll of TX to RX or RX to TX). See BOTC- SEG-0200 section 7 for BNC and coax material. 7

8 J) SDI 270 Mb/s audio/video coax for VS411 modules on : The can have up to nine VS411 modules with four 270 Mb/s coax conductors on the drop side. The drop side coax signal direction is TX if module is optical to electrical (-OE suffix on module part number) or RX if module is electrical to optical (-EO suffix on module part number). Step 1 (consult with Service Provider/Telco about connection method): Audio/video coax circuits can be cabled to special audio/video cross connect patch panels or directly to other video equipment (hardwire). Prior to systems. Broadcast Video equipment should not be connected to DSX-3 or DCS due to it s unique signal format. Step 2 (run coax conductors): If TX (VS411 OE suffix), use SDI OUT1 J1, SDI OUT2 J2, SDI OUT3 J3 and SDI OUT4 J4 ports. If RX (VS411 EO suffix), use SDI IN1 J1, SDI IN2 J2, SDI IN3 J3 and SDI IN4 J4 ports. Provide four 90 degree BNC connectors for each module. Run four TX or RX coax conductors from each module to video patch panel (see part N or P) or other video equipment (hardwire with roll of TX to RX or RX to TX). See BOTC-SEG-0200 section 7 for BNC and coax material. K) SDI 270 Mb/s LINE SIDE audio/video coax for VS551 modules on : The can have up to nine VS551 modules. The LINE SIDE signal direction is TX if module is VS551- ADC-SFP encoder or RX if module is VS551-DAC-SFP decoder. The 270 Mb/s LINE SIDE on VS551 modules can be fiber (part F) or coax but not both on the same module. Step 1 (consult with Service Provider/Telco about connection method): Audio/video coax circuits can be cabled to special audio/video cross connect patch panels or directly to other video equipment (hardwire). Prior to systems. Broadcast Video equipment should not be connected to DSX-3 or DCS due to it s unique signal format. Step 2 (run coax conductors): Use SDT1 J2 port. Provide one 90 degree BNC connector for each module. Run one TX or RX coax conductor from each module to video patch panel (see part N or P) or other video equipment (hardwire with roll of TX to RX or RX to TX). See BOTC-SEG-0200 section 7 for BNC and coax material. L) TV1 6 MHz video DROP SIDE coax for VS551 modules on : The can have up to nine VS551 modules. The DROP SIDE coax signal direction is RX if module is VS551-ADC-SFP encoder or TX if module is VS551-DAC-SFP decoder. Step 1 (consult with Service Provider/Telco about connection method): Audio/video coax circuits can be cabled to special audio/video cross connect patch panels or directly to other video equipment (hardwire). Prior to systems. Broadcast Video equipment should not be connected to DSX-3 or DCS due to it s unique signal format. Step 2 (consult with Service Provider/Telco about TV service monitor room): VS551-DAC-SFP decoder modules have a second output on the drop (coax) side that may connect to a TV service monitor room in some COs. Prior to engineering, vendors must consult with Service Provider/Telco personnel about the need for this connection. Step 3 (run coax conductors): Use VS551 module NTSC/PAL J3 port (regular TX or RX signal) and optional NTSC/PAL J4 port (if also running to TV service monitor room). Provide one or two 90 degree BNC connectors for each module. Run one or two TX or RX coax conductors from each module to video patch panel (see part N or P) or other video equipment (hardwire with roll of TX to RX or RX to TX). See BOTC-SEG-0200 section 7 for BNC and coax material. 8

9 M) TV KHz audio cable for VS551 modules on : The can have up to nine VS551 modules. The DROP SIDE cable signal direction is RX if module is VS551-ADC-SFP encoder or TX if module is VS551-DAC-SFP decoder. Step 1 (consult with Service Provider/Telco about connection method): Audio cable circuits can be cabled to special audio/video cross connect patch panels or directly to other video equipment (hardwire). Prior to systems. Broadcast Video equipment should not be connected to DSX-1 or DCS due to it s unique signal format. Step 2 (consult with Service Provider/Telco about number of audio circuits): NTSC TV1 service consists of one 6 MHz video channel and 0, 2 (shelf circuit 1 and 2) or 4 (shelf circuit 1, 2, 3 and 4) associated audio circuits (15 or 20 KHz each). Prior to engineering, vendors must consult with Service Provider/Telco personnel about the required number of audio circuits. Step 3 (mount mating connectors): Four mating connectors (three pin for 16 to 28 AWG range) are included with each VS551 module. Mount the connectors in VS551 module CH1 J5, CH2 J6, CH3 J7 and CH4 J8 slots. Step 4 (run audio cable): Each of the mating connectors has three pins (left is undesignated, center is + and right is. Use left/undesignated for the cable pair drain wire, + for the Tip lead (Red) and for the Ring lead (Black). Run one RX (if encoder) or TX (if decoder) cable with required number of pairs for all VS551 modules on shelf to audio patch panel (see part Q or R) or other video equipment (hardwire with roll of TX pair to RX pair or RX pair to TX pair, do not roll Tip and Ring leads with a pair). See BOTC-SEG-0100 section 13 for cable material and methods. N) SDI or TV1 coax connection to video jacks on optional Bittree SBCIPS01 patch panel: Step 1 (stencil panel): SBCIPS01 panel jacks are factory stenciled on the rear side. On the front side upper and lower strip labels (provided with panel), stencil each group of two upper/lower video jacks as 1, 2, 3, 4, 5, 6, 7, 8 reading left to right. Step 2 (consult with Service Provider/Telco about assignments): Since patch panel circuits are internally hardwired, connection of coax from one video system on an upper or lower jack will automatically associate it with another video system that may be terminated on the corresponding lower or upper jack. Prior to engineering, vendors must consult with Service Provider/Telco personnel about patch panel assignments. Step 3 (connect coax conductor): Provide one straight BNC connector (see BOTC-SEG-0200 section 7). Connect coax conductor from part G, H, J, K or L. P) SDI or TV1 coax connection to video jacks on optional ADC PPI2232RS-MVJ patch panel: Step 1 (stencil panel): PPI2232RS-MVJ panel jacks not are factory stenciled. On the front side, stencil upper left jack as 1, upper right as 32, lower left as 33 and lower right as 64. On the rear side, stencil upper left as 32, upper right as 1, lower left as 64 and lower right as 33. Step 2 (consult with Service Provider/Telco about assignments): Since patch panel circuits are internally hardwired, connection of coax from one video system on an upper or lower jack will automatically associate it with another video system that may be terminated on the corresponding lower or upper jack. Prior to engineering, vendors must consult with Service Provider/Telco personnel about patch panel assignments. Step 3 (connect coax conductor): Provide one straight BNC connector (see BOTC-SEG-0200 section 7). Connect coax conductor from part G, H, J, K or L. 9

10 Q) TV1 cable connection to audio jacks on optional Bittree SBCIPS01 patch panel: Step 1 (stencil panel): SBCIPS01 panel jacks are factory stenciled on the rear side. On the front side upper and lower strip labels (provided with panel), stencil each group of eight upper/lower audio jacks as 1, 2, 3, 4, 5, 6, 7, 8 reading left to right. Also stencil each set of eight audio jacks (within each overall group) as A, B, C, D reading left to right (corresponds respectively with VS551 module circuit 1, 2, 3, 4 in part M). Step 2 (consult with Service Provider/Telco about assignments): Since patch panel circuits are internally hardwired, connection of audio cable pairs from one video system on an upper or lower jack will automatically associate it with another video system that may be terminated on the corresponding lower or upper jack. Prior to engineering, vendors must consult with Service Provider/Telco personnel about patch panel assignments. Step 3 (mount mating connectors): 64 mating connectors (three screw for 22 to 26 AWG range) are included with each SBCIPS01. The screws are designated H (for High), L (for Low) and S (for Sleeve). Mount the connectors in 1A to 8D upper and 1A to 8D lower audio jack positions. Step 4 (connect cable pairs): Connect cable pairs from part M. Tip (Red) lead to H screw and Ring (Black) lead to L screw. Step 5 (connect drain wire for each pair): Each cable pair has an individual drain wire that must be connected to the mating connector S screw. SBCIPS01 panels have internal factory straps between associated upper and lower S screws. This meets the BOTC-SEG-0100 section 13 part C ground continuity requirement. R) TV1 cable connection to audio jacks on optional ADC PPS3-14MKIIHN patch panel: Step 1 (consult with Service Provider/Telco about assignments): Since patch panel circuits are internally hardwired, connection of audio cable pairs from one video system on an upper or lower jack will automatically associate it with another video system that may be terminated on the corresponding lower or upper jack. Prior to engineering, vendors must consult with Service Provider/Telco personnel about patch panel assignments. Step 2 (connect cable pairs): Connect cable pairs from part M. Tip (Red) lead to T punch down connector and Ring (Black) lead to R. Step 3 (connect drain wire for each pair): Each cable pair has an individual drain wire that must be connected to the S punch down connector. Since PPS3-14MKIIHN panels do not have internal factory straps between upper and lower S connectors, add a 22 AWG bare wire strap between each set of associated upper and lower S. This meets the BOTC-SEG-0100 section 13 part C ground continuity requirement. The panel has 1-24 and ground symbol lugs but connection is not required since the panel is not used to ground audio cables (ground continuity passes through panel via straps between S connectors). 10

Example Transport Engineering Guide (TEG): Artel DL1220 and DL2701 Broadcast Video -48VDC applications

Example Transport Engineering Guide (TEG): Artel DL1220 and DL2701 Broadcast Video -48VDC applications Example Transport Engineering Guide (TEG): Artel DL1220 and DL2701 Broadcast Video -48VDC applications BOTC-TEG-1250 Section Table of Contents Page DS Data Sheet (weight, footprint, power, heat, timing,

More information

Example Transport Engineering Guide (TEG): DSX-1 Rear Cross Connect

Example Transport Engineering Guide (TEG): DSX-1 Rear Cross Connect Example Transport Engineering Guide (TEG): DSX-1 Rear Cross Connect BOTC-TEG-2290 Section Table of Contents Page DS Data Sheet (weight, footprint, power, heat, timing, alarms/rm, DF blocks, CLEI) 2 1 Overview

More information

Example Transport Engineering Guide (TEG): DSX-3 Rear Cross Connect

Example Transport Engineering Guide (TEG): DSX-3 Rear Cross Connect Example Transport Engineering Guide (TEG): DSX-3 Rear Cross Connect BOTC-TEG-2300 Section Table of Contents Page DS Data Sheet (weight, footprint, power, heat, timing, alarms/rm, DF blocks, CLEI) 2 1 Overview

More information

Bill Oakes Telecom Consultants (BOTC) Copyright All rights reserved. 1

Bill Oakes Telecom Consultants (BOTC) Copyright All rights reserved. 1 BOC-EG-6900 Example ransport Engineering Guide (EG): ellabs 1000 Digital Loop Carrier (previously known as ellabs AccessMAX and AFC UMC1000). Central Office applications. Section able of Contents Page

More information

Broadband Connectivity System II

Broadband Connectivity System II User Manual Applys to: :: 010-3232-0001 :: 010-3224-0001 :: 010-3201-0407 :: 010-3201-0401 :: 010-3201-0410 :: 710-3201-0002 :: 710-3201-0005 :: 710-3201-1001-U :: 710-3201-1002-U :: 710-3201-2001-U ::

More information

SECTION T -- SYNCHRONIZATION

SECTION T -- SYNCHRONIZATION INSTALLATION REQUIREMENTS AT&T January, 2012 Section T, ATT-TP-76300 Revised NA SECTION T -- SYNCHRONIZATION CONTENTS PAGE 1. GENERAL... T-1 1.1. Introduction... T-1 2. REQUIREMENTS... T-2 2.1. General...

More information

INSTRUCTION MANUAL VF MultiDyne. Harnessing The Power of Light

INSTRUCTION MANUAL VF MultiDyne. Harnessing The Power of Light INSTRUCTION MANUAL VF-9000 SERIAL DIGITAL FIBER OPTIC TRANSPORT and DISTRIBUTION SYSTEM FOR SMPTE 259, 292, 424, DVB-ASI, with gigabit ethernet with SNMP & Web page monitoring and other protocols MultiDyne

More information

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES FEATURES w w 1 SDI, up to 3Gbs Supports SMPTE -424M -259M -292M -310M Ethernet EQ s and re-clocks w w 4 analog audio or 2 (AES to Base) Two 4-wires for intercom 3 data (RS232, 422, 485) 4 GPIO 1 1, 2 or

More information

SECTION SYNCHRONIZATION

SECTION SYNCHRONIZATION SECTION 11 -- SYNCHRONIZATION CONTENTS PAGE 1. GENERAL... 11-1 1.1. Introduction... 11-1 2. SYNCHRONIZATION REQUIREMENTS... 11-2 2.1. General... 11-2 2.2. Diversity... 11-2 2.3. Engineering Requirements

More information

BCS 4R DSX-3 Connectivity System. Models , , and User Manual

BCS 4R DSX-3 Connectivity System. Models , , and User Manual BCS 4R DSX-3 Connectivity System Models 010-8332-0410, 010-8332-0401, 010-8324-0410 and 010-8324-0401 User Manual BCS 4R DSX-3 Connectivity System Models 010-8332-0410, 010-8332-0401, 010-8324-0410 and

More information

Truck router (3Gbps/HD/SD/ASI)

Truck router (3Gbps/HD/SD/ASI) NVISION 8288 Truck router (3Gbps/HD/SD/ASI) The ultra-compact NVISION 8288 truck video routers are the world s smallest large routers with full broadcast quality, resilience and advanced control systems.

More information

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE

More information

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39" 7.40" 5.2"

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39 7.40 5.2 The Telemetrics Coax/Fiber Link is an affordable camera control system with increased operating distance. Using frequency multiplexing the following signals are transmitted over a single coaxial cable:

More information

3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual

3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual Manual DigiLink DLC103A Function module 3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater Installation and Operations Manual WWW.ARTEL.COM ii DLC103A Function Module Installation

More information

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber MX/HD-SDI-3G Transmit HD-SDI-3G signals over Fiber Key Features Transmit ASI or SDI signal over one single-mode Fiber Support data rate from 19.4Mb/s to 3Gb/s SMPTE 424M, SMPTE 292M, SMPTE 344M and SMPTE

More information

UTAH 100/UDS Universal Distribution System

UTAH 100/UDS Universal Distribution System UTAH 100/UDS Universal Distribution System The UTAH-100/UDS is a revolutionary approach to signal distribution, combining the flexibility of a multi-rate digital routing switcher with the economy of simple

More information

OPTICAL TRANSMISSION SOLUTION.

OPTICAL TRANSMISSION SOLUTION. CONTROL, EXPANSION AND OPERATION BY IP-BASED NETWORK ADVANCED AND FLEXIBLE SYSTEMS FOR INDOOR AND OUTDOOR APPLICATIONS HIGH QUALITY AND PROFESSIONAL ALL-IN-ONE CONCEPT OPTICAL TRANSMISSION SOLUTION Panasonic

More information

SECTION 7 -- CROSS-CONNECT SYSTEMS

SECTION 7 -- CROSS-CONNECT SYSTEMS DETAIL ENGINEERING REQUIREMENTS AT&T March, 2016 Section 7, ATT-TP-76400 Revised NA SECTION 7 -- CROSS-CONNECT SYSTEMS CONTENTS PAGE 1. GENERAL... 7-2 1.1. Introduction... 7-2 1.2. Cable Holes... 7-2 1.3.

More information

EBU Technical Recommendation R Connectors for camera cables with fibre optical transmission

EBU Technical Recommendation R Connectors for camera cables with fibre optical transmission Connectors for camera cables with fibre optical transmission EBU UER EBU Committee First Issued Revised Re-issued PMC 1999 Keywords: Cameras, digital processing, fibre optical transmission The EBU has

More information

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form

More information

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male Serial Data Communications Synchronous, Asynchronous or Isochronous Signal rates: DC to 20 MHz FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male Supported Interface Standards TIA-530, TIA-530A TIA-232 TIA-574

More information

DS1 Cross-Aisle Panel

DS1 Cross-Aisle Panel DS1 Cross-Aisle Panel Model 005-0005-0100 Installation Guide 1.1 Overview 1.1.1 Inspection Compare the contents of the DS1 Cross-Aisle Panel shipping container with the packing list. Call Telect if anything

More information

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX 4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX 1 Contents CHAPTER 1. INTRODUCTION... 2 1.1 OVERVIEW...2 1.2 FEATURE...2 1.3 APPLICATION...3

More information

I N S T R U C T I O N D A T A

I N S T R U C T I O N D A T A I N S T R U C T I O N D A T A RFL (C37.94) Fiber Service Unit Single Mode 108015-1 RS-449 108015-2 V.35 108015-3 G.703 108015-4 X.21 108015-5 E1 Multimode 107460-1 RS-449 107460-2 V.35 107460-3 G.703 107460-4

More information

Model /29S RF Splitter

Model /29S RF Splitter Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary

More information

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual Manual DigiLink DLC156 Function modules Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI Installation and Operations Manual WWW.ARTEL.COM ii DLC156 Function Modules Installation and Operations Manual

More information

MULTIDYNE Electronics, Inc. Innovations in Television Testing & distribution

MULTIDYNE Electronics, Inc. Innovations in Television Testing & distribution INSTRUCTION MANUAL DVM-2200 DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM MULTIDYNE Electronics, Inc. Innovations in Television Testing & distribution 1-(800)-4TV-TEST, 1-(800)-488-8378

More information

Model 5240 Digital to Analog Key Converter Data Pack

Model 5240 Digital to Analog Key Converter Data Pack Model 5240 Digital to Analog Key Converter Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0 This data pack provides detailed installation, configuration and operation information for the 5240 Digital

More information

COPYRIGHT 2016 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

COPYRIGHT 2016 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED HD, SD SDI VBI/VANC encoder A Synapse product COPYRIGHT 2016 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM WITHOUT THE PERMISSION OF AXON DIGITAL DESIGN

More information

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0.

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0. SM06 Advanced Composite Video Interface: HD-SDI to acvi converter module User Manual Revision 0.4 1 st May 2017 Page 1 of 26 Revision History Date Revisions Version 17-07-2016 First Draft. 0.1 28-08-2016

More information

The Art of Engineering

The Art of Engineering The Art of Engineering Functionality DPST Switch DPST Sensing Switch Transfer Switch Passive Splitter Ethernet Switch ASI 3G Switch or DA E/T Switch Optical Switch up to 006 MHz L-Band Broadband Ethernet

More information

10MHz Source/Inserter

10MHz Source/Inserter Instruction Manual Model 2099-218 10MHz Source/Inserter Redundant 18V January 2011, Rev. A RX 0.32 A TX 0.86 A REF ON REF OFF MENU MODEL 2099 SOURCE/INSERTER CROSS TECHNOLOGIES INC. PS1 PS2 REMOTE ALARM

More information

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual User Manual F M2SDI 2 Ch Tx & Rx HD SDI Fiber Optic Link with RS 485 & Aux User Manual CHAPTER 1. SYSTEM INTRODUCTION 1.1 OVERVIEW 1.2 FEATURE 1.3 APPLICATION CHAPTER 2. F M2SDI ENCLOSURES 2.1 FRONT PANEL

More information

Index Contents: 1000 Series Single Channel Multi Mode Fiber Optic Video Solutions Product Overview Product Configurations Product Specifications

Index Contents: 1000 Series Single Channel Multi Mode Fiber Optic Video Solutions Product Overview Product Configurations Product Specifications Welcome Nitek is a Rolling Meadows, Illinois based manufacturing company with a primary focus on design, development and manufacturing of high performance, reliable CCTV video transmission systems. Nitek

More information

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Installation. SAPTF33xx-1xx in the Network. Standard Configuration SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device

More information

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual User Manual F M1SDI 1 Ch Tx & Rx HD SDI Fiber Optic Link with RS 485 User Manual 1Introduction 1.1Overview 1.2Features 1.3Application 2 Panel 2.1 Front Panel 2.2 Rear Panel 3Technical Specification Contents

More information

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

Model 5250 Five Channel Digital to Analog Video Converter Data Pack Model 5250 Five Channel Digital to Analog Video Converter Data Pack E NSEMBLE D E S I G N S Revision 3.1 SW v2.0.1 This data pack provides detailed installation, configuration and operation information

More information

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

Model 6010 Four Channel 20-Bit Audio ADC Data Pack Model 6010 Four Channel 20-Bit Audio ADC Data Pack Revision 3.1 SW v1.0.0 This data pack provides detailed installation, configuration and operation information for the Model 6010 Four Channel 20-bit Audio

More information

ENGINEERING BEYOND THE SIGNAL COMPACT CONVERSION. PEAK PERFORMANCE.

ENGINEERING BEYOND THE SIGNAL COMPACT CONVERSION. PEAK PERFORMANCE. ENGINEERING BEYOND THE SIGNAL COMPACT CONVERSION. PEAK PERFORMANCE. THROW- DOWN WITH BLUE BOX COMPACT CONVERSION. PEAK PERFORMANCE. Delivering excellent performance and a small footprint, Blue Box low-cost

More information

RSS-2T RF Broadband Automatic Switching Station

RSS-2T RF Broadband Automatic Switching Station RSS-2T RF Broadband Automatic Switching Station The RSS-2T is designed for the redundancy of analog RF channels, QAM RF channels, and CATV RF- Broadband feeds in Headend and Hub sites. The RSS automatic

More information

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK Model MX3257HD Description The rack-mountable MX3257HD fiber optic video multiplexer is ideal for transmitting 1 channel of video, 2 channels

More information

TAHOMA opengear frame

TAHOMA opengear frame TAHOMA opengear frame The opengear Frame OG3-FR-CN Apantac opengear implementation uses the OG3-FR-CN frame that comes with cooling and Advanced GigE Network Control This frame has superior flexibility,

More information

GNS600 SCTE104 VANC inserter, Ethernet data-bridge for 3G, HD and SD SDI Inputs and X31 Cue encoder/decoder

GNS600 SCTE104 VANC inserter, Ethernet data-bridge for 3G, HD and SD SDI Inputs and X31 Cue encoder/decoder VANC inserter, Ethernet data-bridge for 3G, HD and SD SDI Inputs and X31 Cue encoder/decoder A Synapse product COPYRIGHT 2018 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE

More information

DIGITAL SWITCHERS 2100 SERIES

DIGITAL SWITCHERS 2100 SERIES DIGITAL SWITCHERS 00 SERIES HIGH PERFORMANCE DIGITAL ROUTING OPERATORS MANUAL Includes Module and Frame Information for: AUDIO DAS- DAS-88 DAS-66 VIDEO DVS- DVS-8 DVS-6 DVM-66 DVS-66 SIGMA ELECTRONICS,

More information

MODEL NVISION 8500 NVISION 8500 ENTERPRISE CLASS ROUTERS. New Fiber Connectivity and Hybrid cards for disembedding/embedding digtal audio.

MODEL NVISION 8500 NVISION 8500 ENTERPRISE CLASS ROUTERS. New Fiber Connectivity and Hybrid cards for disembedding/embedding digtal audio. MODEL NVISION 8500 NVISION 8500 ENTERPRISE CLASS ROUTERS New Fiber Connectivity and Hybrid cards for disembedding/embedding digtal audio wwwamtcom NVISION 8500 Enterprise Class Multi-format, Digital Video

More information

FiberLink 3500 Series Transceivers

FiberLink 3500 Series Transceivers MANUAL FiberLink 3500 Series Transceivers 2 or 4 Channel 3G/HD/SD-SDI Transmission over one or two single mode or multimode fibers Installation and Operations Manual WWW.ARTEL.COM Contents Contents Welcome...

More information

E3/DS3 Fibre Extender

E3/DS3 Fibre Extender User Manual E3/DS3 Fibre Extender Black Box Network Services 464 Basingstoke Road, Reading, Berkshire, RG2 0BG Tech: 0118 965 6000 www.blackbox.co.uk CONTENTS 1 Introduction 1 1.1 About the products 1

More information

16 SFP ports and 16 BNC. built in. 24 SFP ports, 8 BNC

16 SFP ports and 16 BNC. built in. 24 SFP ports, 8 BNC Product Overview 2018 BarnOne Frames BTF1-01 BTF1-02 BTF1-03-08 BTF1-03-16 BTF1-04 BTF1-05-08 BTF1-05-16 BTF1-06 BTF1-07-08 BTF1-07-16 BTF1-08-08 BTF1-08-16 16 SFP ports 16 SFP ports and 16 BNC 16 SFP

More information

AT&T January, 2012 Revised December, 2018 TABLE OF CONTENTS SECTION 1--INTRODUCTION...1-1

AT&T January, 2012 Revised December, 2018 TABLE OF CONTENTS SECTION 1--INTRODUCTION...1-1 SECTION 1--INTRODUCTION...1-1 1. General...1-1 1.1. Introduction...1-1 1.2. Purpose...1-2 1.3. Application...1-2 1.4. Definitions...1-3 1.5. General Requirements...1-3 1.6. Proprietary Information...1-5

More information

Instruction Manual Model BlockUpconverter

Instruction Manual Model BlockUpconverter Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT...

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT... TABLE OF CONTENTS 1. OVERVIEW... 1 2. INSTALLATION... 3 2.1. 500DA-3G CONNECTIONS... 3 3. SPECIFICATIONS... 4 3.1. SERIAL VIDEO INPUT... 4 3.2. SERIAL VIDEO OUTPUT... 4 3.3. ELECTRICAL... 4 3.4. PHYSICAL...

More information

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2584-31 Combiner May 2011, Rev. A RF MONITOR GAIN = -15 MENU MODEL 2584 COMBINER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained

More information

FS4 Quick Start Guide

FS4 Quick Start Guide FS4 Quick Start Guide Overview FS4 is AJA s flagship frame synchronizer and converter, offering incredible versatility and connectivity in a sleek and compact 1RU frame for all your 4K/ UltraHD/2K/HD/SD

More information

R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual

R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual 1178.6733.02 01 User Manual The User Manual describes the following R&S OSP-B200R/B200S2 models and accessories: R&S OSP-B200R/B200S2 (1528.3140.02)

More information

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2115-202 Upconverter November 2011, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX 8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX Contents CHAPTER 1. INTRODUCTION... 2 1.1 OVERVIEW... 2 1.2 FEATURE... 2 1.3 APPLICATION... 3 CHAPTER 2. EQUIPMENT VIEW...4 2.1 FRONT

More information

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER Document No: 101035 Revision 02 PAGE 2 C O N T E N T S 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION...

More information

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION VIDEO CONNECTIONS GENERAL PURPOSE INPUTS & OUTPUTS SPECIFICATIONS...

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION VIDEO CONNECTIONS GENERAL PURPOSE INPUTS & OUTPUTS SPECIFICATIONS... TABLE OF CONTENTS 1. OVERVIEW...1 2. INSTALLATION...3 2.1. VIDEO CONNECTIONS... 3 2.2. GENERAL PURPOSE INPUTS & OUTPUTS... 4 3. SPECIFICATIONS...6 3.1. SERIAL DIGITAL VIDEO INPUTS... 6 3.2. SERIAL DIGITAL

More information

DLM471S-5.1 MULTICHANNEL AUDIO LEVEL MASTER OPERATION MANUAL IB B. (Mounted in RMS400 Rack Mount & Power Supply) (One of 4 Typical Cards)

DLM471S-5.1 MULTICHANNEL AUDIO LEVEL MASTER OPERATION MANUAL IB B. (Mounted in RMS400 Rack Mount & Power Supply) (One of 4 Typical Cards) DLM471S-5.1 (Mounted in RMS400 Rack Mount & Power Supply) MULTICHANNEL AUDIO LEVEL MASTER (One of 4 Typical Cards) OPERATION MANUAL IB6432-02B TABLE OF CONTENTS PAGE 1.0 GENERAL DESCRIPTION 2 2.0 INSTALLATION

More information

COPYRIGHT 2011 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

COPYRIGHT 2011 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED GFS-HFS-SFS100/110 3Gb/s, HD, SD frame synchronizer with optional audio shuffler A Synapse product COPYRIGHT 2011 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN

More information

Typical applications:

Typical applications: Typical applications: Managing multiple inputs for growing satellite teleports Extended L-band frequency for Ka-band & HTS applications Routing live traffic to multiple modems ETL s new ultra compact Hurricane

More information

HDB

HDB GDB990-950-900-550-500 HDB990-950-900-550-500 3Gb/s, HD, SD digital or analog audio de-embedder with TWINS dual A Synapse product COPYRIGHT 2012 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS

More information

Max. 4K Capabilities. Chroma Sampling 4:4:4. 4:2: bit³

Max. 4K Capabilities. Chroma Sampling 4:4:4. 4:2: bit³ Specifications IN1808 Series specification Max. 4K Capabilities Resolution and Refresh Rate 4096 x 2160 at 60 Hz² 3840 x 2160 at 60 Hz 4096 x 2160 at 30 Hz Chroma Sampling 4:4:4 Max. Bit Depth per Color

More information

CMN-91. Multiformat Signal Analyzer FEATURES

CMN-91. Multiformat Signal Analyzer FEATURES Multiformat Signal Analyzer You don t have to look hard to see the benefits of the new Videotek Compact Monitor Series including the multiformat signal analyzer with integral LCD. The smallest solution

More information

Digital to analog A/V bridge with SDI processed outputs COPYRIGHT 2010 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

Digital to analog A/V bridge with SDI processed outputs COPYRIGHT 2010 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED Digital to analog A/V bridge with SDI processed outputs A Synapse product COPYRIGHT 2010 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM WITHOUT THE PERMISSION

More information

SingMai Electronics SM06. Advanced Composite Video Interface: DVI/HD-SDI to acvi converter module. User Manual. Revision th December 2016

SingMai Electronics SM06. Advanced Composite Video Interface: DVI/HD-SDI to acvi converter module. User Manual. Revision th December 2016 SM06 Advanced Composite Video Interface: DVI/HD-SDI to acvi converter module User Manual Revision 0.3 30 th December 2016 Page 1 of 23 Revision History Date Revisions Version 17-07-2016 First Draft. 0.1

More information

Fiber Optic Transmission Systems

Fiber Optic Transmission Systems TM Fiber Optic Transmission Systems SHORT FORM CATALOG For cost-effective, interference-free transmission of analog and digital signals by means of modern optical technology. Since 1977 the people of Liteway

More information

3Gb/s, HD and SD and ASI/DVB and SMPTE-310M 8x8 video router ALL RIGHTS RESERVED

3Gb/s, HD and SD and ASI/DVB and SMPTE-310M 8x8 video router ALL RIGHTS RESERVED 3Gb/s, HD and SD and ASI/DVB and SMPTE-310M 8x8 video router A SynCross product COPYRIGHT 2012 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM WITHOUT

More information

FS3. Quick Start Guide. Overview. FS3 Control

FS3. Quick Start Guide. Overview. FS3 Control FS3 Quick Start Guide Overview The new FS3 combines AJA's industry-proven frame synchronization with high-quality 4K up-conversion technology to seamlessly integrate SD and HD signals into 4K workflows.

More information

NOW all HD Panacea Routers offer 3 Gb/s (1080p) performance!

NOW all HD Panacea Routers offer 3 Gb/s (1080p) performance! Small-Scale Routing NOW all HD Routers offer 3 Gb/s (1080p) performance! The affordable, compact routing switcher line is the market leader for small routing applications, offering the largest selection

More information

Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack

Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack E NSEMBLE D E S I G N S Revision 1.3 SW v2.2.1 This data pack provides detailed installation, configuration

More information

TABLE OF CONTENTS 1. OVERVIEW INDIVIDUAL CARD BLOCK DIAGRAMS... 2

TABLE OF CONTENTS 1. OVERVIEW INDIVIDUAL CARD BLOCK DIAGRAMS... 2 TABLE OF CONTENTS. OVERVIEW..... INDIVIDUAL CARD BLOCK DIAGRAMS.... INSTALLATION... 5.. SDI VIDEO CONNECTIONS... 5.. FIBER OPTIC VIDEO CONNECTIONS... 6.3. AUDIO CONNECTIONS... 6.4. ANALOG AUDIO CONNECTIONS

More information

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel 1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed

More information

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package

More information

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams MAXTECH, Inc. Technology for Communications BRC-1000 Series C-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic

More information

The #1 Routing Solution for Mission Critical Applications. Advanced System Control & Interfacing

The #1 Routing Solution for Mission Critical Applications. Advanced System Control & Interfacing HIGH DENSITY ROUTING PLATFORM Overview The #1 Routing Solution for Mission Critical Applications The EQX platform is Evertz flagship routing & distribution solution designed for high availability by adopting

More information

CMSDI G-SDI Matrix

CMSDI G-SDI Matrix CMSDI-44 4 4 3G-SDI Matrix Operation Manual DISCLAIMERS The information in this manual has been carefully checked and is believed to be accurate. Cypress Technology assumes no responsibility for any infringements

More information

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubSat8D - Eight (8) Channels HubSat82D - HubSat8D w/eight (8) HubWayAv Balun/s for s HubSat83D - HubSat8D w/eight (8) HubWayDv

More information

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2016-1250 Downconverter May 2009 Rev A F=2501.750 G=+25.0 MENU MODEL 2016 DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained

More information

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation Data Sheet Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation Description The Cisco Prisma II line of optical network transmission products is an advanced system designed

More information

THE ART OF ENGINEERING

THE ART OF ENGINEERING THE ART OF ENGINEERING Functionality DPST Switch DPST Sensing Switch Transfer Switch Passive Splitter Ethernet Switch ASI 3G Switch or DA E/T Switch Optical Switch up to 006 MHz L-Band Broadband Ethernet

More information

Model GS Port Node 1 GHz with 65/86 MHz split

Model GS Port Node 1 GHz with 65/86 MHz split Model GS7000 4-Port Node 1 GHz with 65/86 MHz split The Model GS7000 4-Port Node is our latest generation 1 GHz optical node platform and utilizes a completely new housing designed for optimal heat dissipation.

More information

High Density Optical Platform for FTTx and HFC

High Density Optical Platform for FTTx and HFC High Density Optical Platform for FTTx and HFC Optical Platform for FTTx and HFC The WISI optical platform Optopus is a highly flexible and high density platform for all kinds of analog optical networks.

More information

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter 8 Ports 16 Ports CATV Single Channel EDFA 1310nm Forward Optical Transmitter The ACI ED5219LGT series is a high-power multi-ports EDFA optical booster with gain spectrum bandwidth from 1545 to 1563 nm

More information

Model 7130 HD Downconverter and Distribution Amplifier Data Pack

Model 7130 HD Downconverter and Distribution Amplifier Data Pack Model 7130 HD Downconverter and Distribution Amplifier Data Pack E NSEMBLE D E S I G N S Revision 1.0 SW v1.0 www.ensembledesigns.com 7130-1 Contents MODULE OVERVIEW 3 Audio Handling 3 Control 3 Metadata

More information

VNS2200 Amplifier & Controller Installation Guide

VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation 1. Determine the installation location for the VNS2200 device. Consider the following when determining the

More information

Specifications MAV Series Matrix Switchers

Specifications MAV Series Matrix Switchers Specifications MAV Series Matrix Switchers Video composite video and S-video models Routing MAV 44 Series... 4 x 4 matrix MAV 48 Series... 4 x 8 matrix MAV 62 Series... 6 x 2 matrix MAV 84 Series... 8

More information

FOM-9010, FOM-9011 and FOM-9012

FOM-9010, FOM-9011 and FOM-9012 Control and Alarm Voltage sense, open collector, or contact inputs Features: FOM-00: Voltage Sense, Open Collector, or Dry Contact Inputs. State Detection for TIA-, TIA-, and TTL Signals. FOM-0: SPDT Form

More information

DM1624, DM1612, DM812

DM1624, DM1612, DM812 Installation Guide Hardware and Software DM Series Digital Processors models DM1624, DM1612, DM812 LECTROSONICS, INC. 1 Installation Specific Information Only This guide covers only installation related

More information

Instruction Manual Model UHF, L-Band, Up/Downconverter

Instruction Manual Model UHF, L-Band, Up/Downconverter Instruction Manual Model 2017-14 UHF, L-Band, Up/Downconverter March 2017, Rev. A RF MONITOR --------- UPCONV-------- MODEL 2017 UP/DOWNCONVERTER RF MONITOR ------- DNCONV-------- DOWNCONVERTER UPCONVERTER

More information

Dual channel HD/SD integrity checking probe with clean switch over function and wings or split screen creation capabilities

Dual channel HD/SD integrity checking probe with clean switch over function and wings or split screen creation capabilities Dual channel HD/SD integrity checking probe with clean switch over function and wings or split screen creation capabilities A Synapse product COPYRIGHT 2009 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO

More information

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs) USER MANUAL MODEL 460RC Rack-Mounted G.70 Coax to Twisted Pair Adapters (BALUNs) An ISO-900 Certified Company Part # 07M460RC-A Doc. #0908UA Revised //98 SALES OFFICE (0) 975-000 TECHNICAL SUPPORT (0)

More information

Instruction Manual Model 2412-x08 Multi-Channel AGC Amplifier

Instruction Manual Model 2412-x08 Multi-Channel AGC Amplifier Instruction Manual Model 2412-x08 Multi-Channel AGC Amplifier 2412-408 Four Channel 2412-308 Three Channel 2412-208 Two Channel 2412-108 One Channel March 2017, Rev. A 1 2 3 4 A B CHANNEL STATUS REMOTE

More information

USER MANUAL. Blackburst, Sync, Audio Tone Generator. For Models BSG-50, RM-50/BSG, SR-50/BSG. Doc Rev. F (C) Copyright 2014

USER MANUAL. Blackburst, Sync, Audio Tone Generator. For Models BSG-50, RM-50/BSG, SR-50/BSG. Doc Rev. F (C) Copyright 2014 HORITA BSG-50 Blackburst, Sync, Audio Tone Generator USER MANUAL For Models BSG-50, RM-50/BSG, SR-50/BSG Doc. 070450 Rev. F (C) Copyright 2014 P.O. Box 3993, Mission Viejo, CA 92690 (949) 489-0240 www.horita.com

More information

Alcatel OmniPCX 4400

Alcatel OmniPCX 4400 SCION xx Z24/Z12board d.01a Section xx - Section xx - SUMMARY Operation... xx. 3 1. Overview... xx. 3 2. nvironment... xx. 4 3. Operating principle... xx. 4 4. Functional blocks... xx. 6 Configuration...

More information

Dual HD input, frame synchronizer, down converter with embedder, de-embedder and CVBS encoder COPYRIGHT 2008 AXON DIGITAL DESIGN BV

Dual HD input, frame synchronizer, down converter with embedder, de-embedder and CVBS encoder COPYRIGHT 2008 AXON DIGITAL DESIGN BV Dual HD input, frame synchronizer, down converter with embedder, de-embedder and CVBS encoder A Synapse product COPYRIGHT 2008 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

Dual channel high-end HD-SDI to SD-SDI/composite down converter with de-embedding function COPYRIGHT 2008 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

Dual channel high-end HD-SDI to SD-SDI/composite down converter with de-embedding function COPYRIGHT 2008 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED Dual channel high-end HD-SDI to SD-SDI/composite down converter with de-embedding function A Synapse product COPYRIGHT 2008 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED

More information

Dual HD input, frame synchronizer, down converter, embedder, CVBS encoder ALL RIGHTS RESERVED

Dual HD input, frame synchronizer, down converter, embedder, CVBS encoder ALL RIGHTS RESERVED Dual HD input, frame synchronizer, down converter, embedder, CVBS encoder A Synapse product COPYRIGHT 2013 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM

More information

12G Broadcast connectors

12G Broadcast connectors 12G Broadcast connectors Delivering 12G in a single punch www.coax-connectors.com Welcome to COAX 12G BNC Plug return loss COAX Connectors Ltd is a leading UK designer, manufacturer and supplier of high

More information