ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS
|
|
- Godwin Perry
- 5 years ago
- Views:
Transcription
1 ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS NOT SUPPLIED PROGRAMMER / TRANSMITTER RECEIVER THIS DOMESTIC STYLE WIRELESS 7 DAY PROGRAMMABLE HEATER CONTROL REPLACES THE TRUMA ULTRAHEAT SWITCH FITTED IN THE OLDER STYLE 60mm BOX. CONTROLS THE 230 VOLT HEATING ONLY. EASY TO INSTALL, REMOVE TWO SCREWS UNPLUG CONNECTOR, REFIT RECEIVER. CAN ALSO BE FITTED INTO ANY PANEL ADJACENT TO THE TRUMA SWITCH WITH SPACE BEHIND AND ACCESS TO THE 12 VOLT ELECTRICAL CONNECTOR. MAINTAIN A LOWER TEMPERATURE THROUGH THE NIGHT. WAKE UP TO A WARM CARAVAN / SHOWER ROOM. IDEAL FOR WINTER CARAVANING AND SEASONAL PITCHES. MICROPROCESSOR CONTROL. PROGRAM SIX DIFFERENT TIME / TEMPERATURES PER DAY. (7 DAYS) USE FOR FROST PROTECTION (PROGRAM NEEDS TO BE SET TO 5 DEGREES) EASY TO READ BLUE BACK LIT DISPLAY. Capricorn Controls Ltd, Thorpe Close, Banbury, OX16 4SW. England Tel: +44 (0) Fax: +44 (0) Pump sales@capricorn-controls.com not supplied with kit. Web: PLEASE DO NOT HESITATE TO CONTACT US WITH ANY ENQUIRIES
2 BASIC INSTALLATION INSTRUCTIONS Receiver ENSURE THE CARAVAN HEATER MAIN POWER SWITCH IS OFF.(UNPLUG MAINS LEAD TO CARAVAN) REMOVE THE TWO BLANKING CAPS FROM THE TRUMA SWITCH, IF FITTED. REMOVE THE TWO FIXING SCREWS. REMOVE REAR COVER FROM TRUMA SWITCH. A SMALL SCREW DRIVER IN THE FOUR SLOTS WILL AID REMOVAL. PIPS MAY BREAK OFF. CAREFULLY UNPLUG THE 10 WAY CONNECTOR FROM EXISTING SWITCH, DO NOT PULL WIRES. EASE LOCATING TABS TO AID REMOVAL OF CONNECTOR. FOLLOWING THE INSTRUCTION SHEET FOR THE RECEIVER REMOVE THE FRONT PLATE. SEE PAGE 5. RECONNECT THE 10 WAY CONNECTOR TO THE RECEIVER OBSERVING CORRECT ORIENTATION. FIT RECEIVER INTO BOX USING THE SPACERS PROVIDED IF REQUIRED. REFIT THE FRONT PLATE TAKING CARE THAT THE SWITCH,LED AND 5 WAY CONNECTOR ARE CORRECTLY LOCATED. PUSH THE TOP OF THE RECEIVER FULLY HOME, DO NOT ADJUST THE TOP FIXING SCREW. TO REMOVE PULL TOP OF RECEIVER TOWARDS YOU. THE RECEIVER CAN BE FITTED INTO A PANEL ADJACENT TO THE TRUMA SWITCH. A 51mm SQUARE HOLE IS REQUIRED TO BE CUT INTO PANEL. A MINIMUM OF 30mm IS REQUIRED BEHIND THE PANEL. IT COULD ALSO BE FITTED INTO A CUPBOARD, AN EXTENSION LEAD WILL BE REQUIRED. ASK FOR DETAILS. OPERATING INSTRUCTIONS FOR ADAPTED RECEIVER. PROGRAM THE TRANSMITTER TO YOUR PREFERED TIME/TEMPERATURE SETTINGS. (PRESS CENTRE OF UP/ DOWN BUTTONS) YOU MAY FIND IT EASIER WITH THE BATTERY COMPARTMENT LID OPEN FIT THE BUILT IN STAND SEE PAGE 4, STAND PROGRAMMER AT DESIRED LOCATION. REMEMBER TO PACK UNIT AWAY WHILST TRAVELLING. PROGRAMMER MAY BE SURFACE MOUNTED,REMOVE BACK PLATE, SEE PAGE 5, FIX TO SURFACE, REFIT PROGRAMMER TO BACK PLATE. SWITCH MAIN POWER SWITCH ON, WAIT FOR 2 SECONDS.IF PROGRAMMER IS NOT CALLING FOR HEAT THE RED LIGHT WILL REMAIN ON FOR APPROX. 3 MINUTES. SELECT AUTO (A) ON THE HEATER FAN CONTROL, SPEED 3. THE FAN WILL RUN VERY SLOW UNTIL TEMPERATURE BUILDS UP SO WARM AIR CAN BE CIRCULATED AROUND CARAVAN. IF YOU REQUIRE ONLY CONVECTION DO NOT SWITCH FAN ON. PRESS PUSH BUTTON TO SELECT REQUIRED HEAT OUTPUT:- YELLOW LED WATTS GREEN LED WATTS RED LED WATTS NO LED LIT - OFF, NO HEAT SELECTED. TOP BLUE LED - CALLING FOR HEAT TOP RED LED - R/F FAILED. SEE INSTALATION # 1 SHEET PAGE 4 IF PROGRAMMER IS CALLING FOR HEAT, THE HEATER WILL OPERATE IN THE NORMAL WAY. 2
3 SIMPLIFIED PROGRAMMING INSTRUCTIONS Transmitter unit. Within programming mode, transmitter unit will automatically resume operating after a delay of 30 seconds if no buttons are pressed. Internal setting (user adjustable) These internal settings are selective, set the Date/Clock before programming this Transmitter unit. Press and hold SET for 6 seconds to enter setting selection mode. Follow the flashing Symbols on LCD to complete following settings. Press centre of button or 1.C/F: Press or to display Fahrenheit or Centigrade. 2.Press OK to enter next setting( 24H/12H) use or buttons to select. Press OK 3.Repeat procedure by pressing OK to set Year, Month, Day, Time, Switching differential (Hysteresis) set at 1. Filter hours. Leave this at as this is not required. 4.Press Ok to complete settings. Setting the required times/temperatures into transmitter. Programming 7-d Each day of week, can be programmed separately. 1. Press SET once to enter program setting, Temp set will flash 2.Press or to set desired temperature set point for 1st program period (MORN) 3.Press Ok to enter start time for1st program Press or to set start time. Continue to set all time/temperatures for Mon (NOON, Break, EVEN, NIGHT) 4.By pressing OK after setting 1st program you can continue to program Tu, We, Th, Fr, Sa, Su. Or see Copy below. 5.When entire programming is completed, pressing Set twice and then OK programmer will start operating. Copy day settings function. 1.Press Set to enter program setting, (temp set flashing) then Press Set again. From will flash 2. Press to select the reference-day. 3. Press Ok after reference-day selected. To will flash. 4.Keep Pressing and OK to select the days of week to copy to. 5.Press OK twice, after desired days for copying are selected, programmer will now be set to RUN. OVERRIDE FUNCTION M BUTTON. Operating guide to each of the 4 modes. A. Temporary Override- Change current temperature setting until next set point. 1.Press or to adjust temperature. Temp. Set will flash. 2.Wait for 10 seconds, thermostat shall automatically run this temporary override set point. (or press OK to run this override without waiting for 10 seconds) 3.While Temporary Override is in running, Pressing OK will revert to normal settings. B. Comfort Override. Change current temperature set point to new set point for desired hours. Thermostat will resume its original Programming after Comfort Override time has ended. 1.Press M 2. Press or to adjust desired temperature. Temp. Set flashing 3. Press OK to select desired hours run time for comfort override 4.Press or to set desired hours (minimum 1 hour). 5. Press OK to run Comfort Override. 6.Press OK again will end Comfort Override. C. Permanent Hold Temperature---Hold temperature at desired set point permanently until it is cancelled. 1.Press M 2. Press M again, Temp. Set will flash. 3.Press or to set desired temperature. Permanent Hold Temp is displayed. 4. Press OK to run Permanent Hold Temperature 5.Press OK again will end Permanent Hold Temperature. D. Temperature Until (Holiday Hold)---Hold temperature at desired set point until specified date. 1.Press M 2. Press M twice again. Temp. Set will flash. 3.Press or to set desired temperature. 3. Press OK to select desired duration of Hold-Temperature Until. 4.Press or to select Month, Press OK, 5.Press or select desired DAY. 5.Press OK to run Hold Temperature Until. 6.Press OK again to end Hold Temperature Until. Reset to factory settings. Pressing OK and together for 6 seconds, Reset will appear in LCD display. Press Reset button. All previous setting shall be deleted, programming will resume its default setting. 3
4 THIS PAGE IS AN EXTRACT FROM THE SYSTEM ORIGINAL DATA SHEET. ULTRA-VANSTAT INSTALLATION # Fixing plug-in stand and replacing batteries Fixing the Plug-in stand on transmitter unit 1.Insert " head Screw driver into position shown above. 2.Push upward. Make sure bevel Faces down Receiver unit R/F signal lost. Led permanently on. Heating will switch off after 10 minutes if R/F transmission does not resume. Manual button. If R/F signal is lost i.e. flat batteries in transmitter, This button can be used to switch heating on or off. When signal is restored temperature is controlled by the transmitter. DO NOT LEAVE IN MANUAL MODE UNATTENDED. 3.Pull stand off back plastic housing. 5.Push down until locking tabs click into place 4.Push stand into storage groove 6.The stand is now fixed. Push stand down to remove When low battery symbol is displayed, change batteries immediately. Do not use rechargeable batteries. Open battery compartment to Access batteries. Upper compartment 2 x AAA to power transmitter. E&OE Lower compartment 2 x AAA to power back light and Transmitter. 4
5 THIS PAGE IS AN EXTRACT FROM THE SYSTEM ORIGINAL DATA SHEET. ULTRA-VANSTAT INSTALLATION # RF Address- Code setting To open and close the Transmitter unit ( A flat head screwdriver will assist removal of cover) To open To close RF Address Code Setting The code (DIP Switches) is set at Capricorn Controls. This will only need to be changed if your system is in close proximity to another Ultra-Vanstat as this could cause erratic operation. 1.Insert screw-driver Into slot as shown in picture 1.Locate tabs as shown. RECEIVER 2.Gently leaver downward to loosen the back plate 2.Press firmly to close. TRANSMITTER 3.Open as shown To open and close the Receiver unit To open To close Switch both Transmitter and Receiver DIP-Switches in the same position i.e. 1 on 2 off 3 off 4 off 1.Pull the top edge of the front plate towards you. Separate the two halves taking care not to damage or move the LED and Switch 1.Place TAB into the slot on the bottom of housing Follow these instructions if the receiver is already mounted into a box or panel in the Caravan TAB 2.Ensure the LED and Switch shaft are located into holes, push forwards then ensure the 5 pin connector lines up with pins at the top of unit, push firmly home. Do not adjust the top screw, the front is held by friction 5
6 GENERAL INFORMATION TH-920D(TX) + RV H Programmable R/F Thermostat-pair This Programmable R/F controlled Room Thermostat-Pair consists of a mobile Transmitter Unit TH-920D(TX) and a Receiver unit RV- 0356/0356H which is designed with flush-mounting structure to fit most commercially available recessed 60 mm. boxes. A surface - mount box for installing this unit can also be used. Its installation requires no wiring between Transmitter & Receiver and can be fitted in any normal operating environment within 30 meters range between the two units. The soft Keys in the Transmitter are made of translucent rubber to allow Blue LED to project through to allow use in dim surroundings. The working frequency is marked on the top right of plastic housing on both Transmitter and Receiver. The marked frequency on both units must be consistent, or this thermostat pair will not operate. The transmitter unit is powered by 4 x AAA Alkaline batteries, 2 batteries to power the thermostat, another 2 to power the Blue backlight and transmitter. Do not use rechargeable batteries. The Receiver unit is powered from the main heater control board behind the Caravan heater, 12 volt DC. Via 10 pin connector behind the Truma switch. Overall weight of system 250grms. Technical Data Transmitter unit TH-920D (TX) 1. Power supply: 1.5 V AAA Battery x 4. Do not use rechargeable batteries. 2.Battery life: 1 year 3.Temperature reading: C/ F selectable by user. 4.Clock format: 24H/12H selectable by user. 5.Temperature sampling rate: 1 minute 6.Switching differential (Hysteresis): 0.5 C C / 1.0 F-2.0 F selectable by user. 7.Temperature control range: 5 35 C 6.Temperature display range : 0 50 C 9.Temperature setting: 1.0 C 10.Programming feature: 7-day 6 time/temperatures per day. 11.Shortest cycle rate protection: 3-minute, default setting deactivated. 12.Non volatile EEPROM ensure no program/setting loss 13.Temperature sensor: NTC 100K at 25 C 14.Working Frequency: (preset.not selectable by user) T433: MHZ T868: MHZ T915:915 MHZ 15.R/F signal transmission cycle: transmits every 3 minutes. 16.Working distance : up to 30 meters 17.Dimension :110.8Wx 104 H x 21.5 D mm Receiver Unit - RV-03561RV-0356H 1. Operating power: 12 volts DC powered from heater main control board in Caravan. 2.Power consumption : 100 ma 3.Output rating: Protected driver output. 4.Storage temperature: -10 C 60 C 5.Working frequency: a mhz b-868.3smhz c-915mhz 6.Working distance : up to 30 Meters 7.lnstallation: 60 mm flush-mount 8.Dimension: 88.0 W x 88.0 H x 39.4 D mm 6
7 NOTES ALSO AVAILABLE FROM CAPRICORN CONTROLS.
8 ULTRA-VANSTAT WHILST EVERY EFFORT HAS BEEN PUT INTO THE DESIGN OF THIS 230 VOLT HEATER SYSTEM IT IS IMPOSSIBLE TO CATER FOR ALL MAKES AND MODELS OF CARAVANS. THE SYSTEM IS FLEXIBLE ENOUGH TO BE FITTED INTO A WIDE VARIETY OF CARAVANS. OUR TEAM ARE ON HAND FOR ANY HELP AND ADVICE YOU MAY NEED. PLEASE FEEL FREE TO CONTACT US AT CAPRICORN CONTROLS AND WE WILL GIVE YOU ALL THE HELP THAT WE CAN. WE ARE ALSO INTERESTED TO RECEIVE FEEDBACK INCLUDING IDEAS TO IMPROVE AND EASE INSTALLATION FOR VARIOUS CARAVANS. SPECIFIC NOTES WILL BE ADDED IN DUE COURSE. WARRANTY. Our warranty applies only if the equipment has been located, installed and maintained strictly in accordance with good engineering practice, our data sheets, operating and installation instructions and drawings. Terms and conditions of sale available upon request. LIABILITY / DISCLAIMER Capricorn Controls LTD will accept no responsibility for incorrect fitting or installation of this equipment that may cause any loss or damage whatsoever arising from any failure, use or misuse of the equipment, nor for any consequential loss arising there from. All equipment supplied has been checked by our engineers to ensure it is in full working order when it leaves our premises. We are available via for pre-sales advise and technical assistance. Any sale is subject to our standard terms and conditions which are available on request. Capricorn Controls Ltd, Thorpe Close, Banbury, OX16 4SW. England Tel: +44 (0) Fax: +44 (0) sales@capricorn-controls.com Web: Please do not hesitate to contact us with any enquiries. BOOKLET ISSUE 3 E&OE 8
TDDFM14 OWNER S MANUAL
TDDFM14 OWNER S MANUAL Table of Contents 3 Installation Features System Selector Switches 6 10 Connecting Wires and Mounting Thermostat 10 Operation (Programming) Programming/Setting Clock Personal Program
More informationThank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.
Instruction Manual TPST501 (569568) - BOSS TM Universal mable Room Thermostat (Wired) (7 day, 5/2 day and 24 hour programme options) Thank you for purchasing this product. If installing for someone else,
More informationThank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.
Instruction Manual TPSE201 (181422) - BOSS TM Universal Programmer TPSE101 (569565) - BOSS TM Universal Timeswitch Thank you for purchasing this product. If installing for someone else, please ensure that
More informationXTM72E & F Real-Time Clock Modules
Capricorn Controls Ltd Data & Application Notes Page 1 of 8 XTM72E & F Real-Time Clock Modules Originally designed to compliment our wide range of Gen-Set controls, these DC powered Real-Time-Clocks have
More informationRT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz
RT505TX T RT505 T505TX TX RT505TX RT505TX RT505TX 5TX Programmable Room o Thermostat RXBC605 RXRT505 RXWBC605 RXST625 RXVBC605 The RT505TX can be used with any of these receivers 868MHz RT505TX RT505TX
More informationSCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver
SCS318 User Instructions SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver Programmable room thermostats are widely recognised as one of the best ways in which
More informationThank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.
Instruction Manual TPSRF51 (957707) - BOSS TM Universal RF Programmable Room Thermostat (Wireless) (7 day, 5/2 day and 24 hour programme options) Thank you for purchasing this product. If installing for
More informationST625TX Digital Room Thermostat
ST625TX Digital Room Thermostat RXBC605 RXST625 RXWBC605 RXVBC605 RXRT505 The ST625TX can be used with any of these receivers 868MHz PRODUCT COMPLIANCE This product complies with the essential requirements
More informationRadio Thermostat Clock
Radio Thermostat Clock Installation & User Instructions Part number: ZU0800009 80.10.1375.7_feeling_ks_fer_en.indd 1 18.04.2013 11:25:42 Table of contents Safety instructions... 3 Product details... 4
More informationProgrammable Room Thermostat With RF
Salus RT500RF Manual:89 10/7/10 23:43 Page 1 Programmable Room Thermostat With RF Instruction Manual Model No RT500RF 2 Salus RT500RF Manual:89 10/7/10 23:43 Page 2 PRODUCT COMPLIANCE This product complies
More informationEN Wireless programmable thermostat
EN Wireless programmable thermostat Contents 1. Installation... 31 2. Description... 32 EN 3. Wireless association... 33 4. Configuration... 34 CF01 - Correcting the temperature measured... 34 CF02 - Temperature
More information24 Hour & 7 Day Digital Immersion Heater Timeswitch Article
24 Hour & 7 Day Digital Immersion Heater Timeswitch Article 943 320 Large 24 hour clock/programme display. Tough flame retardant bezel 1 Enables clock time to be changed. Used to review and change timer
More informationXTM72 Exerciser Timer Module
Capricorn Controls DA01XTM1-1 Data & Application Note Page 1 of 6 XTM72 Exerciser Timer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products This
More informationLP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR
Dual Channel Programmer Part number 25039DR! For GREENSTAR CDi, GREENSTAR i JUNIOR and GREENSTAR Si MODELS also GREENSTAR i SYSTEM and GREENSTAR CDi SYSTEM MODEL(only when used with the optional integral
More informationOperation Guide 6022 ENGLISH
Operation Guide 6022 Control Panel Reset TEMP UP SET CLOCK PROG2 TIME SET Heat/Cool Mode Switch Fan Switch Target Temp TIME SLOT Time EPA PROGRAM COPY HOLD REVIEW FILTER TEMP DOWN Battery Compartment Statement
More information1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.
(1) Specifications: 1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase. 2. Power consumption Normal 2W (MAX 30W) 3. Standard time signal Quartz oscillation 4. Time accuracy
More informationSport-TIMER 3000 TM Instruction Manual
Sport-TIMER 3000 TM Instruction Manual Sport-TIMER 3000 TM Index of Uses Page Sport-TIMER 3000 TM RECORD OF PURCHASE The Sport-TIMER 3000 TM is fully warranted to the original purchaser against any defects
More informationMRX1 1. Getting to know your MRX1 wireless controller
Please read this guide carefully and retain for future use and maintenance. MRX1 1. Getting to know your MRX1 wireless controller Multizone Wireless Controller Installation and User Guide The MRX1 Multizone
More information1 Channel Multi-Purpose Programmer User Instructions
ES1247B 1 Channel Multi-Purpose Programmer User Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect condition
More informationEC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional
B-Tronic EasyControl EC5415B en Assembly and Operating Instructions Wall/hand-held transmitter, 15-channel, bidirectional Important information for: Fitters / Electricians / Users Please forward accordingly!
More informationJunior Max (JR Max ) Controller
Get more done TM Junior Max (JR Max ) Controller stations Operating Instructions Thank you for purchasing this advanced, highly featured Irritrol Junior MAX controller. The Junior MAX is the latest addition
More informationComfort System T-32-P Universal Thermostat. Operation Manual
TM Comfort System T-32-P Universal Thermostat TM O Operation Manual Your new Comfort System T-32-P Universal Thermostat has been built using the highest quality components and design currently available.
More informationACT 10 Digital Keypad Operating & Installation Instructions This manual is found at
ACT 10 Digital Keypad Operating & Installation Instructions 18-00001 This manual is found at www.eaglesecuritysolutions.co.uk Installation Notes Always remember to factory default the controller before
More informationInstallation & Programming Manual. Please read before using this timer.
Installation & Programming Manual Please read before using this timer. Warning! This unit operates using two fresh, high-quality AA alkaline batteries.batteries must be installed for unit to operate. USE
More informationInserting the batteries. Basic settings of the remote control
Inserting the batteries Procedure prior to first use or when changing batteries Remove the back plate to expose the battery tray. Insert 2 x AA 1.5V alkaline batteries. Ensure the polarity of the batteries
More informationS-Series Digital Thermostat. Instruction Manual Model No ST620RF
S-Series Digital Thermostat Instruction Manual Model No ST620RF 2 PRODUCT COMPLIANCE SALUS Controls Plc hereby declares that the radio equipment type 868Mhz is in compliance with Directives 1999/5/EC,
More informationWaterline Room Controller - Type WLCT3
INSTRUCTIONS Introduction Room controller type WLCT3 is a 4-event programmable controller used to control areas with underfloor heating or special features of a WLM3 installation. The standard WLCT3 can
More informationZoneTouch V2 Zone Control System User Manual
ZoneTouch V2 Zone Control System User Manual www.polyaire.com.au 2014 Polyaire Pty Ltd II ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual TABLE OF CONTENTS 1) Features 2 2) Wall Controller Layout
More informationRoom thermostat Instructions for Use. For the user. Instructions for Use. geotherm
Room thermostat Instructions for Use For the user Instructions for Use geotherm GB table of contents HOW TO USE YOUR APPLIANCE 1 Appliance use...2 1.1 Overall view... 2 1.2 Display... 2 1.3 Main screen...
More informationSINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd
SINGLE ZONE CLIMATE ZONING SYSTEM Technical Manual Polyaire Pty Ltd 11-13 White Road GEPPS CROSS South Australia, 5094 Tel: (08) 8349 8466 Fax: (08) 8349 8446 www.polyaire.com.au CONTENTS Features 1 Application
More informationRAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS
RAMMER NEL PROGRAMMER NSTAR Si MODELS INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS .,,' CONTACT INFORMATION MANUAL INFORMATION WORCESTER BOSCH: TECHNICAL: 08705266241 SERVICE: 08547 256206 SPARES:
More informationAspect 2 Circuit Digital Scene Control
Aspect 2 Circuit Digital Scene Control S p e c i f i c a t i o n 2 circuits of trailing edge dimming 500W total between the two circuits Both circuits feature independent overload, short-circuit and open-circuit
More informationINSTALLATION, PROGRAMMING AND OPERATION MANUAL
INSTALLATION, PROGRAMMING AND OPERATION MANUAL DECLARATION OF CONFORMITY CONTENTS This unit has been designed to provide reasonable protection against harmful interference in a residential install. This
More informationSlimline Digital Electric Radiator. Step by Step Programming Guide
Slimline Digital Electric Radiator Step by Step Programming Guide Setting the Clock Press the right button to move the square cursor across to the CLOCK icon. Press OK and the hour number will be flashing.
More informationOperating instructions Through-beam sensor. OJ51xx / / 2004
Operating instructions Through-beam sensor OJ5xx UK 7098 / 0 07 / 004 Contents Function and features... Installation... Installation of the supplied mounting fixture...4 Electrical connection...4 Setting
More informationtalento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description
Operating Instructions talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls The talento 800 controls are one, two and four electronic time switches with 365-day, 7-day and 24-hour
More informationST9100C User Guide. Features
Features Easy to use slider and buttons combined with LoT Technology and an OK button, allows you to confi rm changes and stay in control. PLEASE RESPECT YOUR ENVIRONMENT! Take care to dispose of this
More informationCP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer
CP027 User Operating Instructions Two Channel Central Heating and Hot Water r The CP027 two channel programmer gives independent control over hot water and heating with up to 3 ON/ settings for each day
More informationBattery Operated Controllers
ALL SEASONAL ADJUSTMENT 1 Battery Operated Controllers Owner s Manual and Programming Instructions RUN PRG SENSOR BYPASS SYSTEM OFF CURRENT TIME/DAY ACTIVE MANUAL-ALL STATIONS START TIMES MANUAL-ONE STATION
More informationVMA ACTIVE MATRIX TFT COLOR LCD MONITOR OWNER S MANUAL INSTALLATION GUIDE
VMA6491 6.4 ACTIVE MATRIX TFT COLOR LCD MONITOR OWNER S MANUAL INSTALLATION GUIDE OWNER S MANUAL WARNING! THE CLARION VMA6491 LCD MONITOR IS DESIGNED FOR REAR SEAT PASSENGER VIEWING ONLY. THIS PRODUCT
More informationChannelPlus H17XL Series 2 User Operating Instructions
ChannelPlus H17XL Series 2 User Operating Instructions Single Channel 7 day Timeswitch The ChannelPlus family of electronic programmers offer a range of advanced features coupled with simplified menu driven
More informationEcomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions
Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS Installation Instructions Contents 1.0 Introduction...3 2.0 Safety...3 3.0 In the box...4 4.0 Installation of sensors...5 5.0 Linking transmitter
More informationMaster Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual MidWest Time Control, Incorporated P.O. Box 1108 Owasso, Oklahoma 74055 Phone (918)272-9430 FAX (918)272-9441 www.midwest-time.com EMAIL: sales@midwest-time.com
More informationDIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A
INSTRUCTION MANUAL LISTED DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A FOR TECHNICAL SUPPORT: 888.500.4598 A DIVISION OF NSi INDUSTRIES, LLC USA 800.321.5847 www.nsiindustries.com
More informationTORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT
TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT INSTALLATION UNIT IS TO BE INSTALLED BY A LICENSED ELECTRICIAN 1. To
More informationUser Guide. Color Touchscreen Programmable Thermostat. ComfortSense Model: 13H /2017 Supersedes
User Guide Color Touchscreen Programmable Thermostat ComfortSense 5500 Model: 13H13 507500-02 5/2017 Supersedes 507500-01 TABLE OF CONTENTS Features... 2 Temperature Dial Indicator... 3 Home Screen...
More informationSTX Stairs lighting controller.
Stairs lighting controller STX-1795 The STX-1795 controller serves for a dynamic control of the lighting of stairs. The lighting is switched on for consecutive steps, upwards or downwards, depending on
More informationUSER GUIDE for the. HES92020, HES92021, HES92220 & HES92221 DIMMER Modules
USER GUIDE for the HES92020, HES92021, HES92220 & HES92221 DIMMER Modules User Guide for the Imagine HES92020, HES92021, HES92220 & HES92221 DIMMER Modules Document I434B Issue 2 (21/08/02) Copyright 2002
More informationWDK-2500-STROBE. User Guide
WDK-2500-STROBE User Guide Warning: This device complies with Part 15 of the FCC rules, operation of this device is subject to the following conditions: 1. This device may not cause harmful interference.
More informationINSTALLATION INSTRUCTIONS FOR
INSTALLATION INSTRUCTIONS FOR MODEL 2240LED www.sportablescoreboards.com 1 Table of Contents 8 X 7 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR
More information7 Day Digital Programmer
7 Day Digital Programmer Cat. No. TRT034 Operating & Installation Instructions What is a programmer?...an explanation for householders Programmers allow you to set On and Off time periods. Some models
More information8 PIN PIC PROGRAMMABLE BOARD (DEVELOPMENT BOARD & PROJECT BOARD)
ESSENTIAL INFORMATION BUILD INSTRUCTIONS CHECKING YOUR PCB & FAULT-FINDING MECHANICAL DETAILS HOW THE KIT WORKS LEARN ABOUT PROGRAMMING WITH THIS 8 PIN PIC PROGRAMMABLE BOARD (DEVELOPMENT BOARD & PROJECT
More informationVMA573 and VMA or 7 Wide Screen Color LCD Monitor. Owner s Manual. Installation Guide
VMA573 and VMA773 5.6 or 7 Wide Screen Color LCD Monitor Owner s Manual Installation Guide 7 headrest / stand alone wide monitor 5.6 headrest / stand alone wide monitor 2 WARINING! The Clarion VMA 573
More informationXTAL Bank DDS Version 0.02 Sept Preliminary, highly likely to contain numerous errors
XTAL Bank DDS Version 002 Sept 7 2012 Preliminary, highly likely to contain numerous errors The photo above shows the fully assembled Xtal Bank DDS with 2 DDS modules installed (The kit is normally only
More informationQUARTZ TIME RECORDER. Simplex 300 OPERATION MANUAL
QUARTZ TIME RECORDER Simplex 300 OPERATION MANUAL TABLE OF CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. PRECAUTIONS FEATURES BEFORE USING THE TIME RECORDER Accessories Features Installing Ribbon Cassette Wall Mounting
More informationRD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011
RD - 122 RACK MOUNT DIMMER OWNERS MANUAL VERSION 1.3 03/09/2011 Page 2 of 14 TABLE OF CONTENTS UNIT DESCRIPTION AND FUNCTIONS 3 POWER REQUIREMENTS 3 INSTALLATION 3 PLACEMENT 3 POWER CONNECTIONS 3 OUTPUT
More informationModel 5250 Five Channel Digital to Analog Video Converter Data Pack
Model 5250 Five Channel Digital to Analog Video Converter Data Pack E NSEMBLE D E S I G N S Revision 3.1 SW v2.0.1 This data pack provides detailed installation, configuration and operation information
More informationTIMETRAX SYNC RF WIRELESS DIGITAL CLOCK Installation Instructions
Installation Instructions OVERVIEW Thank you for choosing a TimeTrax Sync RF Wireless Clock System. The TimeTrax RF Wireless Clock System receives dependable, accurate time from the TimeTrax Sync RF Wireless
More informationEZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:
EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models: 8304 8374 8306 8376 8309 8379 8312 8382 THANK YOU for purchasing the EZ Pro Jr. 8300 Series electronic irrigation controller. The
More informationTP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide
TP7001 Range Electronic 7 Day Programmable Room Thermostat Danfoss Heating Installation Guide For a large print version of these instructions please call Marketing on 0845 121 7400. Certification Mark
More informationST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY
ST8-WiFi Timer Installation Guide and Operations Manual AM M D YYYY English Contents ST8-WiFi Timer Installation Guide and Operations Manual Introduction Welcome to Rain Bird... 1 Timer Features... 1 Controls
More informationMaster Time Clock MTC Users Manual
Master Time Clock MTC-6000 Users Manual Midwest Time Control Phone (972)987-4408 Toll Free (888)713-0373 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL
More informationDocumentation VFD clock 8 a clock
Documentation VFD clock 8 a clock This documentation is protected by our copyright. It must not be used for commercial purposes. Congratulations on your purchase of your VFD clock. To guarantee success
More informationCH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide
1 1 CH1 CH2 1 1 CH4 CH 1 CH3 6s Master /Fade CH6 1 SC1 6s SC4 SC2 SC SC3 SC6 Off/Pro AL Fade 6 Pro User guide CONTENTS INTRODUCTION...2 Welcome 2 Safety 2 Supplied items 3 INSTALLATION...4 Mounting 4
More informationINSTALLATION INSTRUCTIONS FOR. MODEL 2230LED
INSTALLATION INSTRUCTIONS FOR MODEL 2230LED www.sportablescoreboards.com 1 Table of Contents MODEL 2230LED... 3 8 X 4 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:...
More informationTV Lift System Model CL-65 Installation Instructions
TV Lift System Model CL-65 Installation Instructions Contact: Support@Nexus21.com Toll Free: (866) 500-5438 Phone: (480) 951-6885 Fax: (480) 951-6879 Revised: 01/17/17 Below is a parts list describing
More informationCOLOUR CHANGING USB LAMP KIT
TEACHING RESOURCES SCHEMES OF WORK DEVELOPING A SPECIFICATION COMPONENT FACTSHEETS HOW TO SOLDER GUIDE SEE AMAZING LIGHTING EFFECTS WITH THIS COLOUR CHANGING USB LAMP KIT Version 2.1 Index of Sheets TEACHING
More informationExternal RF programmable room thermostat 411
External RF programmable room thermostat 411 Installation & Operating Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER RF411 Programmable Room-Thermostat Setting transmitter and receiver partnership
More informationA6 OPERATING INSTRUCTIONS
Amerec s A6 control for the AX steamer is a touch screen control intended to be mounted on a wall, generally in or near the steam bath. It may be mounted directly on the wall surface or, using an optional
More informationCOMPONENTS & COMPONENTS & ACCESSORIES
COMPONENTS & Accessories 135-145 135 COMPONENTS & ACCESSORIES REMOTE CONTROL 137-138 SOAP DISPENSERS 138 MIXING VALVES 139 SOLENOID KEY 140 REMOTE CONTROLS PERFECT TIME CONTROL ASSEMBLY 140 COVER PLATE
More informationSafety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.
Table of Contents Introduction...3 Safety Information...4-6 Before Beginning Installation...7 Installation Guide...8 Wiring Camera & Monitor...9-10 Replacement Installation Diagram...11 Clip-On Installation
More informationServicePlus S17R Series 2 User Operating Instructions
ServicePlus S17R Series 2 User Operating Instructions Single Channel Timeswitch The Horstmann ServicePlus S17R timeswitch will allow up to 3 ON/ settings per 24 hours on a weekly schedule and has a 1 hour
More informationTORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT
TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT FEATURES Single channel signal timer with 2 duration settings 288 signals in 5 minute increments 24
More information7 Day Digital Programmer 3 Channel Surface Mount
7 Day Digital Programmer 3 Channel Surface Mount Model: TRT038N Installation & Operating Instructions 1. General Information These instructions should be read carefully and retained for further reference
More informationHow do I delete a. Remove Here
2 3 4 5 6 Q. A. Frequently Asked Questions Please read before calling Customer Service. Does your system run repeatedly? Q. How do I delete a start time? Q. Where do I leave the LARGE dial? Do NOT set
More informationEntry Level Wind System. English Français Deutsch Nederlands Espagñol Italiano
Entry Level Wind System Français Deutsch Nederlands Espagñol Italiano Entry Level Wind System Important Suitability: the Entry Level Wind System is only recommended for use on cruising boats up to 10.5m
More informationAVE-301T AVE-301R AVE-304T AVE-308T AVE-316T
VGA and Audio CAT-5 AV Extender AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T User Manual V1.2 www.databay.com.tw www.green-box.com.tw Contents 1. Product Introduction...4 2. Product Features...5 3. System
More informationNT-9600 Wireless Barcode Scanner. Introduction
Guangzhou Netum Electronic Technology Co., Ltd TEL: +86 20 82679969*816 FAX: +86 20 82684887 E-mail: scottchiu@gzxlscan.com Address: Unit137, the Pacific Industry Area, Xintang Town, Zengcheng District,
More informationWeekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N
Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control
More informationEntry Level Speed/Depth Display. English Français Deutsch Nederlands Espagñol Italiano
Entry Level Speed/Depth Display Français Deutsch Nederlands Espagñol Italiano Entry Level Speed/Depth Display Important Suitability: the Entry Level Speed/Depth System is only recommended for use on cruising
More informationConverts any TV to Digital. MFR-300 User Guide
Converts any TV to Digital MFR-300 User Guide Introduction Thank you for choosing this TVonics Freeview box. Record the serial number in the space provided below (the serial number can be found on the
More informationapple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.
apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Take Apart Apple Cinema HD Display 23" LCD (ADC) 2003 Apple
More informationGAUGEMASTER PRODIGY EXPRESS
GAUGEMASTER PRODIGY EXPRESS DCC01 USER MANUAL Version 1.2 2014 1 T A B L E O F C O N T E N T S 1 Getting Started Introduction Specifications and Features Quick Start Connecting to Your Layout Running a
More informationOwner's Manual DIGITAL TO ANALOG BROADCAST CONVERTER WITH REMOTE CONTROL. Model: CVD508 PLEASE READ BEFORE OPERATING THIS EQUIPMENT.
Size: 148.5(W) x 210(H)mm (A5) DIGITAL TO ANALOG BROADCAST CONVERTER WITH REMOTE CONTROL Owner's Manual PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Model: CVD508 FCC NOTICE: To assure continued compliance,
More informationSAUTER flexotron RDT405 Manual
SAUTER flexotron 400 - RDT405 Manual P100012100 Table of contents DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Fr. Sauter AG however, makes no warranties
More informationDLP200M 2 Relay Module for Heating and Cooling Plants
Product Sheet TH6.24 Thermostat Type DLP200M DLP200M 2 Relay Module for Heating and Cooling Plants The DLP 200 M is a relay module for activation of loads (namely thermal actuators or circulators) in wireless
More informationInstruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1
Instruction Manual 2.4G Digital Wireless Four Channel Transmitter System RVS-554W 1 NOTE! Please read all of the installation instructions carefully before installing the product. Improper installation
More informationCP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch
CP017 USER OPERATING INSTRUCTIONS Single Channel Timeswitch The CP017 timeswitch will allow up to 3 ON/ settings per day for each day of the week and has a 1 hour manual boost and advance button to temporarily
More informationQUICK START GUIDE SL-6. Powering and Wireless System for the 688 Field Production Mixer
QUICK START GUIDE Powering and Wireless System for the 688 Field Production Mixer Welcome Thank you for purchasing the, the powering and wireless system that simplifies interconnection between the 688
More informationAccess Control Keypad for MK-DV, JB-DV
#91173 0406 Access Control Keypad for MK-DV, JB-DV - INSTRUCTIONS - The KVI is a surface mount electronic access control keypad for use with Aiphone s MK-DV or JB-DV video door station. Designed with the
More informationVITEK VTM-TLM191 VTM-TLM240
VTM-TLM191 VTM-TLM240 19 & 24 Professional LED Monitors with HDMI, VGA, and Looping BNC VITEK FEATURES 19 & 24 Wide Screen LED Display Panel HDMI, VGA, and Looping BNC Composite Video Inputs & Stereo Audio
More informationLifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA
Lifestyle Dual Channel Programmer for heating AND hot water Installation and User Instructions DUAL CHANNEL 06490197001 ISSA INSTALLATION INSTRUCTIONS PLEASE NOTE: INSTALLATION MUST ONLY BE CARRIED OUT
More informationThe smart valve with 3 Independent programs + 2 extra modes
All right reserved to netafim / Hendelmade 0901 The smart valve with 3 Independent programs + 2 etra modes o opcion rio pro READ & KEEP E AQUA PRO Irrigation Controller Easy to use battery operated irrigation
More informationINSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING:
MSB12906121MAN UK English INSTALLATION AND OPERATING MANUAL FOR ALL MATSUKO SWITCHBOX MODELS SWB 5 SWB 5P SWB 5P+PG WARNING: Ensure that the Matsuko Switchbox is switched off at the mains before you attempt
More informationInstruction Manual Model BlockUpconverter
Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationVT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide
VT1040 10.4 VGA TFT NEMA 4/12 Flat Panel Monitor User s Guide 301040(A) (was document no. 920A0001 version 1.1), revised 01/98 Viewtronix Viewtronix reserves the right to make changes in specifications
More informationUser interface. Abbreviations / Meanings
RG66012649 User interface Contents Page Abbreviations / Meanings Abbreviations / meanings... 2 Button Identification... 3 On-screen Indicators... 4 Quick Start... 5 Setting the time and day... 5 Changing
More informationN3ZI Digital Dial Manual For kit with Backlit LCD Rev 4.00 Jan 2013 PCB
N3ZI Digital Dial Manual For kit with Backlit LCD Rev 4.00 Jan 2013 PCB Kit Components Item Qty Designator Part Color/Marking PCB 1 LCD Display 1 LCD 1602 Volt Regulator 1 U1 78L05, Black TO-92 Prescaler
More informationModel 5240 Digital to Analog Key Converter Data Pack
Model 5240 Digital to Analog Key Converter Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0 This data pack provides detailed installation, configuration and operation information for the 5240 Digital
More informationN3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012
N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012 Kit properly assembled and configured for Standard Serial LCD (LCD Not yet connected) Kit Components Item Qty Designator Part Color/Marking
More information