ANSI C63.4 and CISPR 22-Harmony

Size: px
Start display at page:

Download "ANSI C63.4 and CISPR 22-Harmony"

Transcription

1 ANSI C63.4 and CISPR 22-Harmony at Last? Donald N. Heirman Lucent Technologies, Bell Laboratories Innovations Holmdel, New Jersey USA Abstract: This paper compares the most prevalent emission measurement procedures used internationally-ansi C63.4 and CISPR 22. In the past year, an amendment to CISPR 22 has been approved and published which contains much of the test setup and principles contained in ANSI C63.4. However, there are differences which my affect the test results. These differences are specifically addressed in this paper with the view of their significance in the measurement result, if any. The reader should be able to use this paper to prove that one test is possible to show conformance to the respective limits, provided the same option is selected from both standards. Introduction It has taken over 10 years of effort to develop radiated and conducted emission test techniques for digital devices in the United States. The FCC had various publications which contained their emission measurement techniques such as their now replaced Measurement Procedure Number 4 (MP-4) [l]. Test site requirements (in particular requirements for an open area test site (OATS)) and limits were in another part of their Rules. All, except the limits location which remains in the FCC Part 15 Rules, changed first with the FCC s adoption of ANSI C63.4 in 1991 [2]. This ANSI document was updated a year later to its present version [3]. Both the 1991 and later the1992 documents replaced MP-4 measurement methods and at the same time included test site requirements all in one place. Since 1985, a parallel effort has been underway internationally to develop an international version of MP-4 at the start. That work was conducted in the International Electrotechnical Commission (IEC) Special International Committee on Radio Interference (CISPR). In fact if the reader reviews the 1985 edition of CISPR 22, it contains similar language to that of MP-4. Since then through the efforts of the US delegation to CISPR, wording in C63.4 was proposed as additions to CISPR 22. This lead to the publication of the second edition of CISPR 22 in December of 1993 which picked up one of the most important part of C63.4-the addition of test site validation identical to that in C63.4 for so-called alternates to open area test sites (OATS@[4]. In parallel to the effort to update CISPR 22, the US delegation also proposed and it was accepted to have the site validation for OATS in CISPR 16, Part 1 [S]. But the necessary convergence of the CISPR work and that of C63.4 was still incomplete in that the second edition of CISPR 22 still did not have test setups which is the hallmark of the C63.4 documents (both in the 1991 and 1992 versions). That last detail came about in August of 1996 when the second amendment of CISPR 22 was approved and published [6]. The amendment now has test setups which are virtually identical to those in C63.4. But the word virtually sends shakes through any test community which is concerned with repeatability and answering the question: can one test be done to meet both the CISPR 22 requirements as well as the FCC s C63.4 requirements? This paper will describe the similarities and in particular look at significant differences between the two documents that, in the author s opinion, may affect measurements results, Comparison between CISPR 22, Amendment 2, and C63.4 Definitions The definition of Equipment Under Test was modified slightly in Clause 3.2 in Amendment 2 of CISPR 22 by indicating that the EUT is used for evaluation purposes rather than being evaluated. In C63.4, the EUT is defined further to indicate that it is representative of a product to be marketed. The C63.4 definition brings in the representative nature of the EUT as it is marketed, clearly showing the emphasis on the use of the typical use of the EUT by the consumer. The CISPR 22 definition does not. EUT con&m&on There is a departure in the amendment to CISPR 22, Second Edition. In Amendment 2, the concept of preliminary or initial testing is introduced as is also contained in C63.4. The bulk of the disturbance maximization process is included in these preliminary or initial tests. Within the context of preliminary testing, Amendment 2, clause 9.1.1, requires that investigations shall be made at a number of significant frequencies to give confidence that the probable frequency of maximum disturbance (this is used instead of interference) has been found with respect to the limit. This shall be done while the EUT is being rnn through its typical modes of operation and cable positions in a test setup which is representative of typical system configurations. In C63.4, /97/$

2 there is a more explicit requirement to manipulate cables (See Clauses (conducted emissions) and (radiated emissions)). Further in C63.4, clauses and , cable manipulation is explicitly mentioned, but warns that the cables shall never be placed on top of or under the EUT or its components (unless such placement is inherent in the EUT design). Thus, Amendment 2 requires less maximization based on cable manipulation than C63.4 and hence C63.4 may be considered more rigorous in this respect. In both Amendment 2 and in C63.4 there are many test setups are used for these initial tests. If there are multiple interface ports of the same type, Amendment 2 indicates that the number of additional cables populating these ports shall be limited to the condition where adding another cable does not decrease the margin by, for example, 2 de!. Note that in C63.4 where there are multiple identical ports, there is a requirement in clause to cease adding cabling when the change is less than 2 de? aped the emissions are below the limit. Though the wording is somewhat different, the intent is the same. Hence, both CISPR 22, Amendment 2, and C63.4 are equivalent in employing preliminary testing to determine the configuration, mode of operation and cable position that yields the maximum emission at a particular frequency which has the least margin with respect to the limit. To summarize, the extent of cable manipulation is significantly reduced in Amendment 2 to that which is representative of typical system configurations. In C63.4, there is more cable manipulation guidance for the maximization process used in preliminary testing. It is interesting to note that in C63.4, clause , it states that for floor-standing equipment, cabling should be installed as it would be by the user and no further manipulation is made. In this case, no cable manipulation is allowed. No such guidance is given in Amendment 2. The basic guidance, however, is identical to that in Amendment 2, i.e. use typical or representative configurations. The next change that Amendment 2 made to the second edition of CISPR 22 was to introduce how to handle multiple modules such as plug-in cards and boards. As usual the multiple modules should be a mix of those which can be added and that the number to use is representative. Amendment 2 then indicates that the number of modules used should be limited that when another module is attached, the margin with respect to the limit is not reduced by for example 2 db. C63.4 indicates that the addition of modules should stop when the change in emissions are less than 2 dl3. Hence, in both standards the rule for adding more modules is virtually the same as that for adding additional cabling to identical ports. Amendment 2 then goes into considerable detail for two examples of a minimum representative configuration: a personal computer or computer peripheral and a point of sale terminal. The configuration for personal computers or their peripherals are identical to that in C63.4, Clause The point of sale terminal configuration is not contained in C63.4 and hence for such EUTs, Amendment 2 should be used when conducting C63.4 tests since that configuration is not in conflict with the general guidance in C63.4. Amendment 2 also adds a clause which allows equipment which might be a subsystem of a distributed system such as a data processing terminal, workstation, and private branch telecommunications exchange to be tested independently of a host or system. In addition, distributed networks such as local area networks may be simulated on the test site by lengths of cables and actual peripherals or remote network communications simulators located so that these simulators do not affect the emissions. The ability to measure the subsystem and to simulate distributed networks is also allowed in Clause of C63-4. Emission Maximization As in C63.4, Amendment 2 has a two step process where initial measurements are made first to identify the highest disturbance relative to the limit while the EUT is operated in its typical modes of operation and cables located in its representative positions for a typical system configuration. To show samples of these representative setups, Amendment 2 introduces 10 setup figures. These figures are quite close to those in C63.4 and are described in the Comparison of Test Setups section of the paper to follow. Using the figures will help determine the frequency where the highest emissions with respect to the limit are found and the associated cable position, configuration, and modes of operation of the EUT at this frequency is fixed and identified. C63.4 splits up this preliminary testing in separate clauses for conducted emission testing (See Clause 7.2.3) and for radiated emission testing (See Clause ). However, the requirements are the same as for Amendment 2. The second step in the process is the final measurement which is made using the results of the preliminary measurements, but now the entire frequency spectrum covered by the limits are scanned without further changes to the cable position, con@uration, and modes of operation of the EUT found to yield the highest emissions with respect to the limit during preliminary testing. These final tests are covered in Amendment 2, clauses IO (conducted) and 11 (radiated), and C63.4 clauses (conducted) and (radiated). The similarities in these tests are covered in the following section. Of particular interest is that C63.4 also presents radiated emission measurement procedures which 113

3 cover the frequency range 1 to 40 GHz. Amendment 2 does not provide any information for measurements above 1 GHz. However, CISPR Subcommittee G (ITE) has a voting document to amend CISPR 22 to contain limits and a method of measurement up to and including 18 GHz [7]. C63.4 only contains methods of measurement. Applicable limits are called out by regulatory agencies which in the USA is the Federal Communications Commission in their Part 15 Rules and Regulations. EUT Operation In amendment 2, clause 9.2, the operation of the EUT is described. These are the same conditions as shown in clauses 11.1 and6.1 of C63.4. F%ual Display Units Amendment 2, clause contains the operating rules that shall be used when visual display monitors are part of the EUT. This is identical to clause in C63.4. Facsimile Devices reference groundplane a horizontal surface. Thus the EUT can be placed on a non-conductive table 40 cm high with respect to the horizontal conductive groundplane ( normally the floor of a shielded room or open area test site). C63.4, clause prescribes that only a vertical conducting surface shall be used for table-top products. C63.4 does, however. allow the option to not use the vertical conducing surface at the OATS with the proviso that in case of disputes, a measurement using the vertical conducting surface takes precedence. Finally, for floor-standing EUTs, both standards do not require the use of a vertical conducting reference groundplane. These differences may have an impact on the emissions measured. Clearly, the coupling that is present with the bottom of a table-top device next to a horizontal reference conducting groundplane is different than the coupling of the back of the device to a vertical reference conducting groundplane. Hence to meet the requirements of both standards for one test, it is prudent to select the vertical reference conducting groundplane and the EUT and peripherals located on the 80 cm high table-top. This arrangement is allowed in both standards. Amendment 2, clause presents the mode of operation to use in measuring emissions f?om a facsimile machine. It also notes that for such devices, the referenced test pattern may have to be sent many times to obtain the full disturbance potential of the device. There is no such product specific instructions in C63.4. Telephone Sets Clause in Amendment 2 cites the mode of operation that shall be used when testing telephone sets which are capable of transmitting voice information using digital signals (and hence classified as an ITE). The received signal uses a referenced standard speech data pattern. C63.4 does not specify this product specific test condition. This concludes the comparisons for the general measurement conditions for both standards. Mains (AC) Ports Conducted Disturbance Measurements Amendment 2, clause 10.2 introduces the second LISN (AMN) which is used to power all non-eut mains cords (including those non-eut cords which are connected to a multiple outlet power strip which in turn is connected to the second LISN (AMN). This matches clause of C63.4. Groundplane Clause 10.3 of Amendment 2 includes the option of measuring conducted emissions for table-top EUTs with the Equipment Setup for Conducted Measurements Clause 10.4 of Amendment 2 introduces several test setup figures that are used during the conducted emission tests. These figures are very similar to those in C63.4 and are further described later in this paper in the section on Comparison of Test Setups. The figures in Amendment 2 show the option of referring the measurement to either a vertical or horizontal reference conducting groundplane with the EUT 80 or 40 cm above the floor, respectively. Recording of Conducted Measurements Amendment 2, clause 10.5 indicates that only those emissions that are within 20 db of the limit are to be recorded. In that band, only the amplitudes of the frequencies of the 6 highest emissions with respect to the limit are recorded for each mains port (of the EUT). The current carrying conductor within each mains cord for which these emissions were recorded must be identified. This requirement is the same as C63.4, clause That C63.4 clause goes further to state that if emission amplitudes are more than 20 db below the limit, then the level of the instrumentation noise at representative frequencies shall be recorded. Interestingly in Amendment 2, clause 10.5 also indicates that conducted emissions shall also be recorded at telecommunications ports. This is in anticipation of a further amendment or edition of CISPR 22 which will contain conducted emission requirements and test setups for 114

4 measuring emissions at telecommunications ports between 150 khz and 30 MHz-the same frequency range as that of the mains measurements Equipment Setup for Radiated Disturbance Measurements Clause 11.4, Amendment 2, shows in figures how the EUT shall be contigured and operated for making radiated disturbance measurements for three situations: tabletop, floor-standing and combined floor-standing and tabletop equipment. These figures are quite similar to those in C63.4. The particular comparisons will be discussed in the section on Comparison of Test Setups. The figures showing the use of overhead cable racks in Amendment 2 is more complete than that of C63.4, however. This clause also indicates that if an EUT is designed for both tabletop and floor-standing operation, the EUT shall be tested only in the tabletop configuration, unless the typical installation is floor-standing. Clause of C63.4 has an identical statement but adds that the regulatory authorities require a specific choice for the two configurations. In addition, wall or ceiling mounted equipment shall be tested as tabletop equipment in both standards, Recording of Radiated Disturbance Measurements Clause 11.5, Amendment 2, states that the six highest disturbances with respect to the limit and above 20 db below the limit shall be recorded including the polarization. This is identical to clause in C63.4 which also gives guidance on how to record disturbances when there are less than 6 frequencies which have amplitudes either not above the 20 db below the limits level or are in the noise. This is identical to the instructions for recording conducted emission measurements. Other Comparisons There are many other comparisons that can be made between the 1991 and 1992 editions of C63.4 and the 1985 and 1993 versions of CISPR These comparison will not be repeated in this paper. However, there are a few comparisons of particular interest, The Second Edition of CISPR 22 contains as an Annex tables to use in comparing measured site attenuation with theoretical values for alternate (to an OATS) test sites such as absorber lined rooms and all-weather enclosed open area test sites. These tables are identical to Tables 1 and 2 of C63.4. Note that for the time being in C63.4, an all-weather covered OATS is not considered to fall under the alternate test site normalized site attenuation requirements (See clause of C63.4). However, C63 Subcommittee 1, chaired by the author, is studying the need to remove this exemption. In CISPR, the exemption does not exist. Comparison of Test Setups Perhaps an even easier way to compare C63.4 and CISPR 22, Amendment 2, is to concentrate now on the differences and similarities in the test setup figures. The figures parallel each other so that tabletop and floor-standing setups can be compared directly. There are figures added to CISPR 22 which are not in C63.4 and vice-versa. We start by stating the basic differences and similarities which are in each of the three basic test setups discussed below. Tabletop Setups Conducted Measurements Amendment 2, Figure 4. does not have two peripherals on either side of the EUT as is the case with C63.4 Figure 9 (a). Instead, it just shows one peripheral. Amendment 2, Figure 4, shows an associated equipment connected to at least one of the I/O cables attached to the EUT. That I/O cable lies directly on the conductive groundplane as does the Artificial Mains Note that the AMN is called a Line Impedance Stabilization Network (LISN) in C63.4. C63.4 does not show any location for associated equipment not on the tabletop but the LISN is also located directly on the conductive groundplane. Keyboards for PCs represented in Amendment 2, Figure 4, are close to the EUT CPU; in C63.4, Figure 9 (a), the keyboard is positioned at the front edge of the 1.5 by 1 meter rectangular tabletop. Amendment 2, Figure 4, shows more clearly the position of the AMN, the LISN in C63.4 does not although the text and figure footnote instructions on placements in both standards are clear. Amendment 2, Figures 5 through 7, shows the mounting of the AMN on the conductive groundplane below the EUT or to the reference vertical conducting wall which is located 40 cm from the EUT; C63.4, Figures 9 (a), 9 ( c) and 11 only allows the LISN on the conductive groundplane. When the AMN is located on the vertical wall, the associated equipment can be moved away from the conductive groundplane as shown in Figure 5 in Amendment 2. Both standards allow the use of a multiple outlet strip to power all other equipment which is part of the EUT system under test. Amendment 2, Figure 7, has a setup for conducted emission measurements at an open area test site (OATS) where the vertical conducting surface is not used; C63.4 does not show this setup, but has wording in clause that allows the optional use of the vertical conducting surface when conducted emissions are made at an open area test site. However, in case of disputes, the use of the vertical conducting surface takes precedence. 115

5 Radiated Measurements For radiated emission testing using both standards. the LISN (AMN) is allowed to be used as long as it is installed below the groundplane and the mains (AC) junction box or receptacle is bonded to and flush with the groundplane. The powerline (mains) cord(s) for the EUT is not bundled in this test as it was when connected to the LISN (AMN) for the conducted emission tests. In fact the setups show that all powerline (mains) cords are connected to their power receptacles located immediately under the non-conducting tabletop. This arrangement allows powering the EUT and associated equipment from receptacles located in or near the center of a turntable. Other differences include: 1. Amendment 2, Figure 10, does not show the location of associated equipment (AE) which may be on the turntable or remotely via a cable that goes through the stationary part of the turntable at its center. For the conducted emission measurements using Figures 4, 5, and 7 the location of the AE is clearly shown. 2. Amendment 2 and C63.4 both do not show the use of extension cords for these radiated measurements. Floor Standing Setups Conducted Measurements 1. Amendment 2, Figure 8, shows the location of associated equipment nearby to the EUT and located on the reference groundplane (though not shown explicitly, the AE is insulated from the groundplane); C63.4, Figure 9 (b) does not show any AE. 2. Amendment 2, Figure 8, does not show in the test setup figure the serpentine cable arrangement for I/O cables connecting the two adjacent EUT floor standing cabinets yet in the notes associated with the test setup figure does allow this arrangement only if the excess I/O cable cannot be folded back and forth forming a bundle 30 to 40 cm long; C63.4, Figure 9 (b), explicitly shows an I/O cable bundled in a serpentine fashion, 3. Amendment 2 and C63.4 both show the same arrangement for the primary LISN (AMN) and the secondary LISN (AMN), the latter used for connecting the mains cords for non-eut equipment in the test setup. 4. Both Amendment 2, Figures 13 and 14, and C63.4, Figure 10, show test setups with EUTs which are installed using overhead cable trays and supports. Amendment 2 shows two cabinets as EUTs with cables connecting them via an overhead cable tray; C63.4 shows only 1 EUT cabinet with the interconnecting cables to remote (not on the turntable) associated equipment. For both tests, the LISN (AMN) is located on the turntable next to the EUT (80 cm away) with Amendment 2 indicating that the AMN can be located below and bonded to the conductive groundplane. Radiated Measurements 1. Amendment 2, Figure 11, shows that the only way to handle the excess I/O cable between two adjacent EUT floorstanding cabinets is by the usual bundling (folding back and forth the cable) though in a footnote serpentine bundling is allowed C63.4, Figure 9 (d) allows both types of bundling as well. 2. Amendment 2, Figure 11, allows bundling of the excess powerline (mains) cable between the EUT and the receptacle on the conducting ground plane (insulated above the ground plane by up to 12 mm of insulating material). Amendment 2 also allows the mains cable to be shortened to an appropriate length. C63.4, Figure 9 (d), allows the same conditions for the mains cords. 3. Both standards require the powerline (mains) receptacle to be flush with the groundplane and if LISNs are used, they must be located under the groundplane. Combination Tabletop and Floor-standing EUT systems Amendment 2 has more detail in test setups for the situation where the EUT is comprised of equipment which rests on a tabletop and on the floor (insulated from the conducting groundplane). C63-4, Figure 13, is a generic setup for both conducted and radiated emissions. The details are described below. Conducted Measurements Amendment 2, Figure 9, shows two power mains cords associated with the EUT system. Hence, the location of the two LISNs (AMNs) are clearly shown. The LISNs (AMNs) are 80 cm away from both parts of the EIJT, i.e. the tabletop portion and the floor-standing portion. C63.4, Figure 13, does not show LISNs but the text in the general equipment setup for conducted emissions in clause sets similar requirements for the LISN location. Amendment 2, Figure 9, does not show any I/O cables leading to associated equipment remote from the test site. C63.4. Figure 13, shows how cables exit the test site, but does not show isometric or plan view the relative positions of the tabletop equipment and the floorstanding parts of the EUT system and does not show any I/O cabling between the two parts of the EUT system. Both Amendment 2 and C634. allow for the use of additional LISNs (AMNs) to power associated equipment or equipment which is not being measured for its conducted emissions. 116

6 Radiated Measurements Again, Amendment 2 has more details for this setup. 1. Amendment 2, Figure 12, and C63.4, Figure 13, both show that the LISN (AMN) is removed from above the groundplane for radiated emission measurements. If the EUT is connected to an LISN (AMN), the LISN (AMN) must be mounted under the groundplane for both standards. 2. Amendment 2, Figure 12, shows an I/O cable attached to the floor-standing EUT to simulate connection to remote associated equipment. This connection was not shown in the conducted emission test setup in Figure 9-this is a curious omission, 3. Both Amendment 2 and C63.4 indicate that the floor standing part of the combination EUT comprised of a tabletop and the floor-standing portions should be placed on an insulated surface up to 12 mm in height (C63.4 allows between 3 and 12 mm). In both standards, the tabletop and floor-standing portions of the EUT should be separated with typical spacing. Amendment 2. Figure 12, shows that the I/O cable between the tabletop and the floor-standing units can be draped to the floor but if the cable cannot reach the floor, the cable is draped to the height of the connector of the floor standing unit or 40 cm above the groundplane whichever is lower. C63.4 does not give this guidance. Equipment using overhead cables Conducted and Radiated Emissions Both Amendment 2 and C63.4 show EUT setups where the EUT is a floor-standing rack of equipment and I/O cabling is normally routed from the top of the EUT to an overhead cable manager or rack. Figure 13 in Amendment 2 shows such setups where there are two floor standing racks interconnected via an overhead cable rack, where C63.4 shows a much simpler single rack system where the I/O cable goes to presumably a remote location under the groundplane. In any case, there is more detail in Figure 13, In addition, Amendment 2 splits the setup into two figures: one is a plan view and the other is a front view. The same constraints hold i.e. for radiated emission measurements, the LISN (AMN) must be located below the groundplane with the power receptacle flush with the groundplane. The vertical riser (that part of the cable management system from the groundplane to the overhead rack) used to support the overhead cable rack or manager must be the one that is used when the EUT is installed and that only one cable riser is used for the path from the groundplane to the top horizontal portion of the cable rack (for each floorstanding unit of the EUT system). Summary This paper has shown comparisons of measurement procedures contained in ANSI C63.4 and CISPR 22, Amendment 2. The test setups are so close to each other that it is now possible to show product compliance using either measurement procedure with the possible exception of conducted emissions on tabletop EUTs. In this case, using a 40 cm high tabletop allowed in Amendment 2 instead of the 80 cm tabletop height preference in C63.4 may lead to different results. The procedures in CISPR 22 and its amendments were heavily influenced by contributions of the United States National Committee of the International Electrotechnical Commission and its Special International Committee on Radio Interference (CISPR). The US members (the author was one of the principle contributors) of CISPR Subcommittee G (Information Technology Equipment) were instrumental in getting C63.4 inputs into CISPR 22 in order to harmonize both documents. As will be the case, each document as it is changed will be slightly out of step with each other since both documents do not undergo changes in synch and in time. It is the challenge of the working groups within C63 and CISPR/G to keep their respective documents so synchronized (or maybe integrate into one document). References [l] FCCYOET MP-4 (1983), FCC Measurement Procedure MP-4, FCC Measurement of Radio Noise Emissions from Computing Devices. [2] American National Standard for Methods of Measurement of Radio-Noise from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to 40 GHz, ANSI C [3] American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to 40 GHz, ANSI C [4] CISPR 22 (1993)-Second Edition, Limits and methods of measurement of radio disturbance characteristics of information technology equipment [5] CISPR 16-l (19931, Part 1: Radio disturbance and immunity measuring apparatus [6] CISPR 22 (1996)-Amendment 2, Limits and methods of measurement of radio disturbance characteristics of information technology equipment [7] CIS/G/l18/CD, Proposal for emission limits above 1 GHz, Comments on this draft are due by 30 April [8] D. N. Heirman, Progress in ITE Emission Measurement Methods, 1 lti International Zurich EMC Symposium and Technical Exhibition, 7-9 March

FCC Part 15 Subpart B Test Report. FCC PART 15 Subpart B Class B: 2014

FCC Part 15 Subpart B Test Report. FCC PART 15 Subpart B Class B: 2014 Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 FCC Part 15 Subpart B Test Report FCC PART 15 Subpart B Class B: 2014 Report Reference No...: CTL1408272147-F

More information

Sunlight Supply, Inc.

Sunlight Supply, Inc. FCC Part 18 Subpart C Consumer For RF Lighting Equipment Electromagnetic Compatibility Test Report Sunlight Supply, Inc. Etelligent Compatible Ballast - olt July 19, 2017 Tests Conducted by:, LLC 20811

More information

Test Report. Product Name: Access Point Model No.: MS-6809 FCC ID: DoC

Test Report. Product Name: Access Point Model No.: MS-6809 FCC ID: DoC Test Report Product Name: Access Point Model No.: MS-6809 FCC ID: DoC Applicant : MICRO-STAR INT L Co., LTD Address : No 69, Li-De st., Jung-He City, Taipei Hsien, Taiwan, R.O.C Date of Receipt : June

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 IC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00095-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China TEST

More information

FCC Part 15B Test Report

FCC Part 15B Test Report Shenzhen Toby Technology Co., Ltd. Report No.: TB-FCC111757 Page: 1 of 18 FCC Part 15B Test Report Application No. : TB11081419 Applicant : Ingtron Enterprise Co., Ltd. Equipment Under Test (EUT) EUT Name

More information

Sensoray. Model 819. Tests Conducted by: ElectroMagnetic Investigations, LLC. May 10, 2013

Sensoray. Model 819. Tests Conducted by: ElectroMagnetic Investigations, LLC. May 10, 2013 European Union (EU) Council Directive 2004/108/EC Electromagnetic Compatibility (EMC) and FCC Part 15 Subpart B Class B Test Report for Information Technology Equipment Sensoray Model 819 May 10, 2013

More information

EMC Test Report. 850 Kacena Road Hiawatha, IA 52233

EMC Test Report. 850 Kacena Road Hiawatha, IA 52233 EMC Client: EUT: Crystal Group 850 Kacena Road Hiawatha, IA 52233 Model RS112 No.: R20140819-21 Approved By: Nic S. Johnson, NCE EMC Test Engineering Manager/Technical Manager inarte Certified EMC Engineer

More information

Test Report #: Date: January 24, 2006

Test Report #: Date: January 24, 2006 Test Report #: 2415-1 Date: January 24, 2006 CERTIFICATE #2316.01 Issued To: Jeffrey Samstad American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description

More information

FCC TEST REPORT For. ETI Solid State Lighting (Zhuhai) Ltd. LED downlight Model No.: XX

FCC TEST REPORT For. ETI Solid State Lighting (Zhuhai) Ltd. LED downlight Model No.: XX Page 1 of 24 FCC TEST REPORT For ETI Solid State Lighting (Zhuhai) Ltd LED downlight Model No.: 531931XX Prepared for Address Prepared by Address : ETI Solid State Lighting (Zhuhai) Ltd : No.1, Zhongzhu

More information

EMC TEST REPORT. Product : Digital Camcorder Model No. : SCD5000. SAMSUNG ELECTRONICS Co., Ltd. EMC Test Laboratory. Project No.

EMC TEST REPORT. Product : Digital Camcorder Model No. : SCD5000. SAMSUNG ELECTRONICS Co., Ltd. EMC Test Laboratory. Project No. Page 1 of 17 EMC TEST REPORT Project No. :LBE031059 Product : Digital Camcorder Model No. : SCD5000 Date of test : May 7 ~ 9, 2003 Issued Date : May 9, 2003 Tested by: Jay Yong, PARK / Test Engineer Reviewed

More information

Testing. Maker Works. Applicant: Model No.: FCC ID: Jun., May to 16. Date of Test: PASS* Test Result: Signature: Authorized. this report.

Testing. Maker Works. Applicant: Model No.: FCC ID: Jun., May to 16. Date of Test: PASS* Test Result: Signature: Authorized. this report. 1 Cover Page Shenzhen Zhongjian Nanfang Testing Co., Ltd. FCC REPORT Applicant: Address of Applicant: Maker Works Technology INC Building C3, Floor 4th, Zhiyuan, Xili, Nanshan District, ShenZhen 518057

More information

Test Report. Model No.: NF592XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF592-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 )

Test Report. Model No.: NF592XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF592-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 ) Test Report Applicant: Product Name: Brand Name: Jetway Information Co.,Ltd Motherboard/Barebone N/A Model No.: NF592XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF592-YYYY-ZZ (X,Y & Z: Stands for

More information

FCC PART MEASUREMENT AND TEST REPORT FOR. DongGuan City FLYSKY Remote Model Co., Ltd.

FCC PART MEASUREMENT AND TEST REPORT FOR. DongGuan City FLYSKY Remote Model Co., Ltd. FCC PART 15.249 MEASUREMENT AND TEST REPORT FOR DongGuan City FLYSKY Remote Model Co., Ltd. No.41 Road West, BanHu Village, HuangJiang Town, DongGuan City, GuangDong Porvince, China FCC ID: VPOFLYSKY002

More information

FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd.

FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd. FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT For Tritech Technology Ltd. Unit 8B,Chung pont Commercial Building No.300 Hennessy Road, Wanchai, HongKong Model: 0-545-24967-8, 0-545-24986-4 Report Type:

More information

FCC PART 15B, CLASS B TEST REPORT. Autel Intelligent Tech. Corp., Ltd.

FCC PART 15B, CLASS B TEST REPORT. Autel Intelligent Tech. Corp., Ltd. FCC PART 15B, CLASS B TEST REPORT For Autel Intelligent Tech. Corp., Ltd. 6th - 10th Floor, Bldg. B1, Zhiyuan, Xueyuan Rd., Xili, Nanshan Shenzhen China FCC ID: WQ8MAXISYSMY906 Report Type: Original Report

More information

FCC REPORT. Report Reference No... : TRE R/C.: Simbans Picasso 10 Inch Tablet

FCC REPORT. Report Reference No... : TRE R/C.: Simbans Picasso 10 Inch Tablet FCC REPORT Report Reference No.... : TRE1704011605 R/C.:59884 FCC ID... : Applicant s name... : Address... : Manufacturer...: Address...: Test item description... : Trade Mark... : Model/Type reference...

More information

CONTENTS 6.2 TEST SET-UP...16

CONTENTS 6.2 TEST SET-UP...16 CONTENTS 1. GENERAL INFORMATION...3 2. INTRODUCTION...4 3. PRODUCT INFORMATION...5 3.1 DESCRIPTION OF EUT...5 3.2 SUPPORT EQUIPMENT / CABLES USED...6 3.3 MODIFICATION ITEM(S)...6 4. DESCRIPTION OF TESTS...7

More information

Open Rack Specification 2.1 Update

Open Rack Specification 2.1 Update Rack and Power Open Rack Specification 2.1 Update Steve Mills Technical Lead Facebook Busbar Thickness Tolerance Reduction Reduce Rack Frame Tolerance Agenda Add Appendix D: Optional Rack-level EMI test

More information

384A Adapter Installation Instructions

384A Adapter Installation Instructions Instruction Sheet 860237684 Issue 9, October 2012 SYSTIMAX Solutions 384A Adapter Installation Instructions General The 384A adapter (Figure 1) is a broadband video adapter that provides connectivity to

More information

FCC TEST REPORT for Aeon Labs LLC. Aeon Minimote Model No.: DS03202B-ZWUS, DS03202W-ZWUS

FCC TEST REPORT for Aeon Labs LLC. Aeon Minimote Model No.: DS03202B-ZWUS, DS03202W-ZWUS Page 1 of 22 FCC TEST REPORT for Aeon Labs LLC. Aeon Minimote Model No.: DS03202B-ZWUS, DS03202W-ZWUS Prepared for Address Prepared By Address : Aeon Labs LLC. : 121 Buckingham drive, unit36 santa claras

More information

FCC ID: IMK-ILCISA EMI TEST REPORT

FCC ID: IMK-ILCISA EMI TEST REPORT 15.247 Certification FCC ID: IMK-ILCISA EMI TEST REPORT On SYMPHONY ISA Card Prepared for Proxim 295 N. Bernardo Ave Mountain View, CA 94043 Tel: (650)960-1630 Fax: (650)960-0332 Prepared by Electronic

More information

EMC Standards Alert. Timely Updates on Critical Standards. In this issue

EMC Standards Alert. Timely Updates on Critical Standards. In this issue EMC Standards Alert Timely Updates on Critical Standards Edited by Don Heirman, Chair of IEC/ CISPR & ANSI ASC C63 Editorial Board Harry H. Hodes - Acme Testing Co. Doug Kramer - NCEE Mike Violette - Washington

More information

FCC test report. Via Pezza Alta, 13 I Rustignè di Oderzo (TV)

FCC test report. Via Pezza Alta, 13 I Rustignè di Oderzo (TV) Test report nr. 20811FCC11 Measurements performed in accordance with: FCC Rules: code of Federal Regulations (CFR) no. 47 PART 15 RADIO FREQUENCY DEVICES Product: Tested model: FCC ID Applicant: Manufacturer:

More information

T E S T - R E P O R T. No for. SLG 42 MOBY Component

T E S T - R E P O R T. No for. SLG 42 MOBY Component Straubing, August 04, 1998 T E S T - R E P O R T No. 51905-80643-0 for SLG 42 MOBY Component Applicant: Purpose of Testing: Siemens AG To show compliance with FCC Rules Part 15, Subpart C section 15.209

More information

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCIS15010007003 1 Cover Page FCC REPORT Applicant: Address of Applicant: Interglobe Connection Corp 7500 NW 25 th Street 112 Miami, Florida 33122 USA Equipment Under Test (EUT) Product Name:

More information

FCC Report. Beijing Visual World Technology Co.,Ltd.

FCC Report. Beijing Visual World Technology Co.,Ltd. FCC Report Report No.: GTS201703000097F01 Applicant: Beijing Visual World Technology Co.,Ltd. Address of Applicant: 15th Floor and 17th Floor 1701-10A, Building 3, No. 10, Jiuxianqiao Road Jia, Chaoyang

More information

Test result 1. Conducted emission EN 55022: A1:2007 EA 3 passed 2. Radiated emission <1GHz (others)

Test result 1. Conducted emission EN 55022: A1:2007 EA 3 passed 2. Radiated emission <1GHz (others) SHARP EMC Testing Laboratory Test Report No.: 11/250-02 page TR-2 of TR-13 5 SUMMARY OF TEST RESULTS Emission testing No. Item Test procedure Page code Number of pages Test result 1. Conducted emission

More information

FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT

FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT FCC PART 15 CLASS B EMI MEASUREMENT AND TEST REPORT For XIAMEN YEALINK NETWORK TECHNOLOGY CO., LTD. 7/F HuaLian Electronic BLDG., No.580 JiaHe Road, XiaMen, China September 26, 2005 This Report Concerns:

More information

FCC PART TEST REPORT. HHC Changzhou Corp.

FCC PART TEST REPORT. HHC Changzhou Corp. FCC PART 15.249 TEST REPORT For HHC Changzhou Corp. No 61, Xinggang Road, Zhonglou District, Changzhou, Jiangsu, China, 213023 FCC ID: 2AEQWCB20HHC011 Report Type: Original Report Product Type: Control

More information

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F Test Report Product Name: IQ Pager (Receiver) FCCID: WDC-IQ2008 Model No.: IQ2008 Applicant: HME Wireless, Inc. 1400 Northbrook Parkway, Suite 320, Suwanee City, GA, 30024, U.S.A Date Receipt : 12/20/2008

More information

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F

THRU Lab & Engineering , Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do, , Korea T /F Test Report Product Name: IQ Pager (Receiver) FCCID: WDC-IQ2008 Model No.: IQ2008L Applicant: HME Wireless, Inc. 1400 Northbrook Parkway, Suite 320, Suwanee City, GA, 30024, U.S.A Date Receipt : 12/20/2008

More information

TABLE OF CONTENTS 1. GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY

TABLE OF CONTENTS 1. GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY FCC Rule(s): FCC Part 15B Measurement and Test Report Product Description: Tested Model: Report No.: For GlobTek, Inc. 186 Veterans Dr. Northvale, NJ 07647 USA FCC Part 15 Subpart B X-PLORE 8000 STANDARD

More information

CHAO WEI ELECTRONICS CO., LTD. FCC REPORT CHAO WEI ELECTRONICS CO., LTD.

CHAO WEI ELECTRONICS CO., LTD. FCC REPORT CHAO WEI ELECTRONICS CO., LTD. CHAO WEI ELECTRONICS CO., LTD. FCC REPORT Prepared For : CHAO WEI ELECTRONICS CO., LTD. No.8, Xianglong Road, Xiagang, Changantown, Dongguan City, China Product Name: Model : DVB-T ANTENNA CW-DVB66, CW-DVB83,

More information

T E S T - R E P O R T. No for PC24E-11-FC/R. RF-modem for wireless LAN. Agere Systems Nederland B.V.

T E S T - R E P O R T. No for PC24E-11-FC/R. RF-modem for wireless LAN. Agere Systems Nederland B.V. EMV-Prüfzentrum EMI/EMC-Testcenter Straubing, September 5, 2001 T E S T - R E P O R T No. 56305-10552-1 for RF-modem for wireless LAN Purpose of testing: To show compliance with FCC Code of Federal Regulations,

More information

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras Eng Installation Instructions F D E NL I IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before

More information

Order Number : GETEC-C FCC Part 15 subpart B Test Report Number : GETEC-E Page 2 / 32 CONTENTS

Order Number : GETEC-C FCC Part 15 subpart B Test Report Number : GETEC-E Page 2 / 32 CONTENTS Test Report Number : GETEC-E3-12-032 Page 2 / 32 CONTENTS 1. GENERAL INFORMATION... 3 2. INTRODUCTION... 4 3. PRODUCT INFORMATION... 5 3.1 DESCRIPTION OF EUT... 5 3.2 SUPPORT EQUIPMENT / CABLES USED...

More information

TEST REPORT. Power Spout PLT V. tested to. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

TEST REPORT. Power Spout PLT V. tested to. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices EMC Technologies (NZ) Ltd PO Box 68-307,Newton Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100

More information

FCC Test Report. Color LCD Monitor

FCC Test Report. Color LCD Monitor Underwriters Laboratories Inc. www.ul.com/emc www.ulk.co.kr Project: 10CA46552 File: TC8352 Report: 10CA46552-FCC Date: October 13, 2010 Model: EX190W (Basic), RadiForce EX190W FCC Test Report For Color

More information

FCC REPORT Q6WBT * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT Q6WBT * In the configuration tested, the EUT complied with the standards specified above. 1 Cover Page Report No: CCIS12110026101 FCC REPORT Applicant: Address of Applicant: Equipment Under Test (EUT) GUANGDONG STEELMATE SECURITY CO., LTD Renan Street, Dong fu Road, Dongfeng Town,Zhongshan,

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD TEST REPORT FROM RFI GLOBAL SERVICES LTD Test of: D-MINI-2108-2019 FCC ID: NEO-DMINI21082019 To: FCC Parts 2.1046; 2.1049; 22.913(a); 22.917; 24.232; 24.238 & 15.107 3GPP TS 36.143 V10.3.0 This Test Report

More information

Page: 1 of 15 FCC TEST REPORT. : MEGAVIEW DIGITECH LIMITED : C Fu Gui Yuan, Block 80, Bao an District, Shenzhen, China

Page: 1 of 15 FCC TEST REPORT. : MEGAVIEW DIGITECH LIMITED : C Fu Gui Yuan, Block 80, Bao an District, Shenzhen, China Page: 1 of 15 FCC TEST REPORT Reference No. Applicant Address : WT10125265-S-E-F : MEGAVIEW DIGITECH LIMITED : C1-1001 Fu Gui Yuan, Block 80, Bao an District, Shenzhen, China Equipment Under Test (EUT)

More information

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC FCC ID TEST REPORT

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC FCC ID TEST REPORT CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC ID TEST REPORT TEST REPORT NUMBER : CGZ3150520-00565-EF TEST REPORT For FCC ID 47 CFR PART 15 OCT, 2014 Report Reference No....

More information

TEST REPORT. Test Report No. : UL-RPT-RP JD18L V2.0. Manufacturer : Neeo AG. Model No. : 6336-BRAIN FCC ID : 2AKK7-BR633601

TEST REPORT. Test Report No. : UL-RPT-RP JD18L V2.0. Manufacturer : Neeo AG. Model No. : 6336-BRAIN FCC ID : 2AKK7-BR633601 TEST REPORT Test Report No. : UL-RPT-RP11456397JD18L V2.0 Manufacturer : Neeo AG Model No. : 6336-BRAIN FCC ID : 2AKK7-BR633601 Test Standard(s) : FCC Part 15.207 1. This test report shall not be reproduced

More information

What really changes with Category 6

What really changes with Category 6 1 What really changes with Category 6 Category 6, the standard recently completed by TIA/EIA, represents an important accomplishment for the telecommunications industry. Find out which are the actual differences

More information

We, International Standards Laboratory, hereby certify that:

We, International Standards Laboratory, hereby certify that: Product Name Model(s) Applicant Address Issue Date: February 12, 2014 Ref. Report No. ISL-14HE043FA : Robust Computing System : RCS-7422-610QW; RCS-7xxx; RCS-7400; RCS-7200; RCS-7220-610QW; RCS-7211-610QW

More information

FCC Part 15 Certification Test Report. 433 MHz Alarm System

FCC Part 15 Certification Test Report. 433 MHz Alarm System FCC Part 15 Certification Test Report 433 MHz Alarm System FCC ID: Q6K 1000-7253 FCC Rule Part: 15.231 ACS Report Number: 03-0111-15B Manufacturer: 3SI Security Systems Model: 1000-7253 with variants Test

More information

FCC Report (WIFI) Shenzhen Reo-link Digital Technology Co., Ltd B509, University Town Business Park LiShan Road, NanShan, Shenzhen, Guangdong, China

FCC Report (WIFI) Shenzhen Reo-link Digital Technology Co., Ltd B509, University Town Business Park LiShan Road, NanShan, Shenzhen, Guangdong, China FCC Report (WIFI) Applicant: Address of Applicant: Manufacturer/y: Address of Manufacturer/y: Equipment Under Test (EUT) Product Name: Shenzhen Reo-link Digital Technology Co., Ltd B509, University Town

More information

APPLICATION OF CERTIFICATION For. TTE Technology Inc. LCD TV FCC ID: W8ULE32HDE3000

APPLICATION OF CERTIFICATION For. TTE Technology Inc. LCD TV FCC ID: W8ULE32HDE3000 FCC ID:W8ULE32HDE3000 APPLICATION OF CERTIFICATION For TTE Technology Inc. LCD TV Brand Name TCL Model Number LE32HDE3000; LE32HDE3011 LE32HDE5311; LE32HDF3310TA LE32HDF3311; LE32HDF3312 FCC ID: W8ULE32HDE3000

More information

SMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0

SMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0 Proposed SMPTE Standard for Television Date: TP Rev 0 SMPTE 424M-2005 SMPTE Technology Committee N 26 on File Management and Networking Technology SMPTE STANDARD- --- 3 Gb/s Signal/Data Serial

More information

Power Injector 1520 Series

Power Injector 1520 Series Power Injector 1520 Series Technical Specifications Input voltage 100 to 240 VAC Output voltage 56.0 VDC Voltage range tolerance 54 VDC to 57 VDC Maximum current 1.43 A No load current 15 ma 56VDC@0.71A

More information

Specifications. Reference Documentation. Performance Conditions

Specifications. Reference Documentation. Performance Conditions The material in this section is organized into two main groupings: the specification tables and the supporting figures. The specification tables include: 1. PAL general and test signal specifications 2.

More information

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 76 2007 Antenna Selector Switches NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards are

More information

Date: ESPOO Page: 1 (10) Appendices. Tyre Pressure Monitoring Device. Flextronics International Finland.

Date: ESPOO Page: 1 (10) Appendices. Tyre Pressure Monitoring Device. Flextronics International Finland. TEST REPORT Date: ESPOO 25.04.2003 Page: 1 (10) Appendices Number: 1031681 No.1/1 Date of handing in: 07.04.2003 Testedby: Timo Leismala, Product Manager Reviewed by: Janne Nyman, Product Manager, EMC

More information

ONETECH Testing & Eval. Lab. VERIFICATION FCC RULES PARTS 2 & 15 CLASS A DIGITAL DEVICE. for AUTHORIZED. Win4NET Co., Ltd.

ONETECH Testing & Eval. Lab. VERIFICATION FCC RULES PARTS 2 & 15 CLASS A DIGITAL DEVICE. for AUTHORIZED. Win4NET Co., Ltd. ONETECH Testing & Eval. Lab. VERIFICATION FCC RULES PARTS 2 & 15 CLASS A DIGITAL DEVICE for PRODUCT: VIDEO CODEC MODEL NAME: NetSafe-VC3001 AUTHORIZED Win4NET Co., Ltd. KOLON Digital Tower 1301, 222-7,

More information

CONTENTS 1. GENERAL INFORMATION INTRODUCTION PRODUCT INFORMATION DESCRIPTION OF TESTS CHANNEL BANDWIDTH...

CONTENTS 1. GENERAL INFORMATION INTRODUCTION PRODUCT INFORMATION DESCRIPTION OF TESTS CHANNEL BANDWIDTH... Test Report Number : GETEC-E3-09-083 Page 2 / 33 CONTENTS. GENERAL INFORMATION...4 2. INTRODUCTION...5 3. PRODUCT INFORMATION...6 3. DESCRIPTION OF EUT...6 3.2 SUPPORT EQUIPMENT / CABLES USED...7 3.3 MODIFICATION

More information

PicoScope 4000 Automotive PC Oscilloscopes

PicoScope 4000 Automotive PC Oscilloscopes PicoScope 4000 Automotive PC Oscilloscopes User's Manual ps4000a.en-1 Copyright 2008 Pico Technology Ltd. All rights reserved. Contents I Contents 1 Introduction...1 1 Overview...1...1 2 Minimum PC requirements...2

More information

WVR500 Waveform/Vector Monitor

WVR500 Waveform/Vector Monitor Service Manual WVR500 Waveform/Vector Monitor 070-8897-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are

More information

CEA Standard. Standard Definition TV Analog Component Video Interface CEA D R-2012

CEA Standard. Standard Definition TV Analog Component Video Interface CEA D R-2012 CEA Standard Standard Definition TV Analog Component Video Interface CEA-770.2-D R-2012 April 2007 NOTICE Consumer Electronics Association (CEA ) Standards, Bulletins and other technical publications are

More information

Test Report. Product Name : PC2PC-Bluetooth Model No. : MS-6967 FCC ID. : I4L-MS6967

Test Report. Product Name : PC2PC-Bluetooth Model No. : MS-6967 FCC ID. : I4L-MS6967 Test Report Product Name : PC2PC-Bluetooth Model No. : MS-6967 FCC ID. : I4L-MS6967 Applicant : MICRO-STAR INT'L Co., LTD. Address : No. 69, Li-De St, Jung-He City, Taipei Hsieh, Taiwan, R.O.C. Date of

More information

Receiver Description and Installation

Receiver Description and Installation Receiver Front Panel Smart Card Door Behind this door is a slot for a future smart card. No smart card is included with this receiver. Arrow Buttons Use the ARROW buttons to change channels on the nearby

More information

PicoScope 3000 Series Automotive User guide

PicoScope 3000 Series Automotive User guide PicoScope 3000 Series Automotive User guide PS3000A044 v1.0 I PicoScope 3000 Series Automotive PC Oscilloscopes Table of Contents 1 Introduction...2...2 1 Overview...2 2 Minimum PC requirements...2 3 Installation

More information

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu - IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution Presented by PowerDsine: David Pincu - davidp@powerdsine.com Objectives! Investigate the Channel /Link options! Identify the requirements

More information

CERTIFICATION APPLICATION TEST REPORT

CERTIFICATION APPLICATION TEST REPORT BEC INCORPORATED CERTIFICATION APPLICATION TEST REPORT TEST STANDARDS: FCC Part 15 Subpart C, Section 15.247 Intentional Radiator ARRIS Model VMS4100 Set Top Box FCC ID: ACQ-VMS4100 REPORT BEC-1792-03

More information

NOTICE. (Formulated under the cognizance of the CTA R4.8 DTV Interface Subcommittee.)

NOTICE. (Formulated under the cognizance of the CTA R4.8 DTV Interface Subcommittee.) CTA Standard Standard Definition TV Analog Component Video Interface CTA-770.2-D S-2017 (Formerly CEA-770.2-D R-2012) April 2007 NOTICE Consumer Technology Association (CTA) Standards, Bulletins and other

More information

FCC Test Report (Class II Permissive Change)

FCC Test Report (Class II Permissive Change) FCC Test Report (Class II Permissive Change) Product Name Intel Wireless-AC 9560 Model No. 9560NGW FCC ID. 2AKHF9560NG Applicant TONGFANG HONGKONG (SUZHOU) LIMITED Address NO. 83 Wu Lane, Suzhou Industrial

More information

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to: This specification describes the situation of the Proximus network and services. It will be subject to modifications for corrections or when the network or the services will be modified. The reader is

More information

Technical Standards and Requirements for Radio Apparatus Capable of Receiving Television Broadcasting

Technical Standards and Requirements for Radio Apparatus Capable of Receiving Television Broadcasting Issue 3 February 2015 Spectrum Management and Telecommunications Broadcasting Equipment Technical Standard Technical Standards and Requirements for Radio Apparatus Capable of Receiving Television Broadcasting

More information

Introduction...2. Features...2 Safety Precautions...2. Installation...4

Introduction...2. Features...2 Safety Precautions...2. Installation...4 PE1900 Contents Introduction...2 Features...2 Safety Precautions...2 Installation...4 Unpacking the Display...4 Locations and Functions of Controls...4 Connections...5 Using Your Display...7 Turning the

More information

Dell Wyse 5030 PCoIP Zero Client

Dell Wyse 5030 PCoIP Zero Client Dell Wyse 5030 PCoIP Zero Client User Guide Regulatory Model: PxN Regulatory Type: PxN001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Voice Messaging Outcalling Quick Reference

Voice Messaging Outcalling Quick Reference Voice Messaging Outcalling Quick Reference 585-300-70 Comcode 10730735 Issue 1 Copyright 199, Lucent Technologies All Rights Reserved Printed in U.S.A. Notice Every effort was made to ensure that the information

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 48-3 2011 Test Procedure for Measuring Shielding Effectiveness of Braided Coaxial Drop Cable Using the GTEM Cell

More information

Page: 1 of 19 EMC TEST REPORT EN55024:1998+A2:2003

Page: 1 of 19 EMC TEST REPORT EN55024:1998+A2:2003 Page: 1 of 19 EMC TEST REPORT Reference No. Applicant : WT05110894 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Card reader Model No : USB2.0A LL-in-1 Standards : EN55022:1998+A2:2003

More information

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE) PART 1: GENERAL 1.01 Telecommunications Engineer Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE) B. Registered Communications Distribution Designer

More information

FCC PART TEST REPORT SHANGHAI MERIT TECHNOLOGY CORP.

FCC PART TEST REPORT SHANGHAI MERIT TECHNOLOGY CORP. FCC PART 15.247 TEST REPORT For SHANGHAI MERIT TECHNOLOGY CORP. 1058 TAOGAN RD., SHESHAN TOWN, SONGJIANG DISTRICT, SHANGHAI, China FCC ID: XJ6MT-180H Report Type: Original Report Product Type: 4CH 2.4GHZ

More information

OPTICA TECHNOLOGIES INCORPORATED and the OPTICA TECHNOLOGIES INCORPORATED logo are trademarks of Optica Technologies Incorporated.

OPTICA TECHNOLOGIES INCORPORATED and the OPTICA TECHNOLOGIES INCORPORATED logo are trademarks of Optica Technologies Incorporated. Optica Technologies Incorporated 34600 FXBT Converter Quick Start Guide Product Warranty Safety Warnings 34600/070208 Trademarks OPTICA TECHNOLOGIES INCORPORATED and the OPTICA TECHNOLOGIES INCORPORATED

More information

In-Line or 75 Ohm In-Line

In-Line or 75 Ohm In-Line or 5 Ohm 1dB Adjustable Gain 800/1900 Smart Technology Contents: Quick Install Overview.... 2 Installation Diagram.... Understanding the Lights... 9 Warnings and Recommendations....11 Appearance of device

More information

2.0 Wall Mount TV Soundbar Instruction Manual

2.0 Wall Mount TV Soundbar Instruction Manual 8010275 2.0 Wall Mount TV Soundbar Instruction Manual Read all of the instructions before using this soundbar and keep the manual in a safe place for future reference. Safety Information CA UT IO N RISK

More information

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at Connevans.info Solutions to improve the quality of life Offering you choice Helping you choose This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk

More information

User s Manual. Document # , Rev 1.2, 6/12/2006

User s Manual. Document # , Rev 1.2, 6/12/2006 CAMERA LINK TM VIDEO SPLITTER User s Manual Document # 200205, Rev 1.2, 6/12/2006 Vivid Engineering 418 Boston Turnpike #104 Shrewsbury, MA 01545 Phone 508.842.0165 Fax 508.842.8930 www.vividengineering.com

More information

Register your product and get support at SDV5122/27. EN User manual

Register your product and get support at   SDV5122/27. EN User manual Register your product and get support at www.philips.com/welcome SDV5122/27 User manual Contents 1 Important 4 Safety 4 Notice for USA 5 Notice for Canada 5 Recycling 6 English 2 Your SDV5122 7 Overview

More information

SDTV 1 DigitalSignal/Data - Serial Digital Interface

SDTV 1 DigitalSignal/Data - Serial Digital Interface SMPTE 2005 All rights reserved SMPTE Standard for Television Date: 2005-12 08 SMPTE 259M Revision of 259M - 1997 SMPTE Technology Committee N26 on File Management & Networking Technology TP Rev 1 SDTV

More information

FCC Report (WIFI) Red Bear Company Limited. RedBear IoT phat 2ABXJ-PHAT-IOT

FCC Report (WIFI) Red Bear Company Limited. RedBear IoT phat 2ABXJ-PHAT-IOT Report No.: GTS201607000065E01 FCC Report (WIFI) Applicant: Red Bear Company ed Address of Applicant: 1711 Block B, Wah Luen Industrial Centre, 15-21 Wong Chuk Yeung Street, Fo Tan, Hong Kong Equipment

More information

Versatile EMS and EMI measurements for the automobile sector

Versatile EMS and EMI measurements for the automobile sector EMC/FIELD STRENGTH EMC Measurement Software R&S EMC32-A Versatile EMS and EMI measurements for the automobile sector EMC Measurement Software R&S EMC32-A (automotive) from Rohde & Schwarz is a powerful

More information

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents PART 1 - GENERAL 1.1 SUMMARY SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors. 3. Cabling system identification products. 1.2

More information

Digital Feedback Eliminator

Digital Feedback Eliminator Digital Feedback Eliminator Installation and Use Manual Issue 1, October 1999 1999 Bogen Communications, Inc. All rights reserved. 54-2027-01 9910 Model: LUFDBKEL PEC Code: 5335-611 COM Code: 408184265

More information

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780 Component Video / VGA Over UTP Video Transmission Systems Manual #: UMA1074 Rev. 2 October, 2007 Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780 Table of Contents 1.0 GENERAL DESCRIPTION...

More information

CHAPTER 3 SEPARATION OF CONDUCTED EMI

CHAPTER 3 SEPARATION OF CONDUCTED EMI 54 CHAPTER 3 SEPARATION OF CONDUCTED EMI The basic principle of noise separator is described in this chapter. The construction of the hardware and its actual performance are reported. This chapter proposes

More information

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor True FLAT P-CAP LCD Monitor User Manual Installation Guide 15 True FLAT P-CAP Touch LCD Monitor MODEL: KKF1500-PCAP i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com

More information

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications March 2006 Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical

More information

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School BILOXI PUBLIC SCHOOL DISTRICT Biloxi Junior High School Request for Proposals E-Rate 2014-2015 - Internal Connections Submit Proposals To: Purchasing Department Attn: Traci Barnett 160 St. Peter Street

More information

SECTION 7 -- CROSS-CONNECT SYSTEMS

SECTION 7 -- CROSS-CONNECT SYSTEMS DETAIL ENGINEERING REQUIREMENTS AT&T March, 2016 Section 7, ATT-TP-76400 Revised NA SECTION 7 -- CROSS-CONNECT SYSTEMS CONTENTS PAGE 1. GENERAL... 7-2 1.1. Introduction... 7-2 1.2. Cable Holes... 7-2 1.3.

More information

CGA0101 Wireless Cable Gateway Quick Installation Guide

CGA0101 Wireless Cable Gateway Quick Installation Guide Package Contents CGA0101 cable modem * 1 Quick Installation Guide * 1 RJ-45 CAT 5e cable * 1 Rear Panel and Hardware Connection 12 V/1.5 A Power Adaptor * 1 Telephone cord * 1 This chapter describes the

More information

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE SAFETY WARNINGS AND GUIDELINES Prior to operation, check the unit and power cord for physical damage. Do not use if physical damage has occurred. Before plugging the unit into a power outlet, ensure that

More information

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor Touch Display LCD Monitor User Manual Installation Guide 15 Resistive Touch LCD Monitor MODEL: KK1500-TR i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com User

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 SOHO 6-Port CAT5e 568B Data Module SEPTEMBER 2003 JPM1101A CUSTOMER SUPPORT

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-6 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 6: Symmetrical pair/quad cables with transmission characteristics up

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Sync Genlock JULY 1993 AC083A. Sync Genlock

Sync Genlock JULY 1993 AC083A. Sync Genlock JULY 1993 AC083A Sync Genlock Sync Genlock SC H PHASE SC 0 SC 180 SLOW LOCK FAST LOCK DISABLE ENABLE ENABLE POWER BURST CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday

More information

Multi Room Audio Matrix Switcher

Multi Room Audio Matrix Switcher Multi Room Audio Matrix Switcher User s Guide 560884 ZONES 1 2 3 4 5 6 7 8 Copyright Clipsal Integrated Systems Pty Ltd 2005. All rights reserved. This material is copyright under Australian and international

More information

Kramer Electronics, Ltd. USER MANUAL. Model: Digital Audio Transcoder

Kramer Electronics, Ltd. USER MANUAL. Model: Digital Audio Transcoder Kramer Electronics, Ltd. USER MANUAL Model: 466 Digital Audio Transcoder Contents Contents 1 Introduction 1 2 Getting Started 1 3 Your Digital Audio Transcoder 1 4 Using the Digital Audio Transcoder 5

More information