EXPRESSION OF INTREST

Similar documents
B-AFM. v East 33rd St., Signal Hill, CA (888)

NP-AFM. Samples as large as 200 x 200 x 20 mm are profiled by the NP-AFM system, and several stage options are available for many types of samples.

TT-2 AFM. This compact, second. generation tabletop Atomic. Force Microscope has all the. important features and benefits. expected from a light

Tender Notification for the procurement of a Scanning Electron Microscope" at IISc (Last Date for submission of tenders: 3 rd October 2018)

Standard Operating Procedure of nanoir2-s

Figure 1: AFM image of a Tip-check sample

TT-AFM. For: up to 1 X 1 X 1/4. Vibrating, Non Vibrating, Phase, LFM. 50 X 50 X 17 μ, 15 X 15 X 7 μ. Zoom to 400X, 2 μ resolution

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

SPM Training Manual Veeco Bioscope II NIFTI-NUANCE Center Northwestern University

Life Sciences Atomic Force Microscope Model ID: LS-AFM-A LS-AFM-B

Decoding the Nanoworld

Precision Nano Displacement System (PNDS)

Live events staging. Media centers

Preface. The information in this document is subject to change without notice and does not represent a commitment on the part of NT-MDT.

[AMBIENT ATOMIC/MAGNETIC FORCE MICROSCOPY MANUAL]

Keysight Technologies Intrinsic Contact Noise: A Figure of Merit for Identifying High Resolution AFMs. Application Note

Figure 1. MFP-3D software tray

Standard AFM Modes User s Manual

The Most Accurate Atomic Force Microscope. Park NX-PTR Fully Automated AFM for Accurate Inline Metrology of Hard Disk Head Sliders.

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

University of MN, Minnesota Nano Center Standard Operating Procedure

Ensemble QLAB. Stand-Alone, 1-4 Axes Piezo Motion Controller. Control 1 to 4 axes of piezo nanopositioning stages in open- or closed-loop operation

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

TT AFM LongBeach Procedures and Protocols V2.1

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

Digital SWIR Scanning Laser Doppler Vibrometer

IMPAC Infrared Thermometers

Scanning Probe Microscope Training. Wenhui Pang

AFM Standard Operating Procedure

USB-TG124A Tracking Generator User Manual

Digital SWIR Scanning Laser Doppler Vibrometer

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

Quick Start Bruker Dimension Icon AFM

Delivery, installation, commissioning and warranty of multi-channel Programmable High Voltage Supply System

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

STANDARD OPERATING PROCEDURE: ASYLUM MFP-3D AFM

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

FLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems

Nova Px SPM Control Program

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Connection for filtered air

Using AFM Phase Lag Data to Identify Microconstituents with Varying Values of Elastic Modulus

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

USA Price List. January or 8-channel LIBSCAN system (100 mj, 1064 nm laser) Alternative LIBSCAN configurations

Quick Start ATOMIC FORCE MICROSCOPE West Campus Imaging Core

SPECIAL SPECIFICATION 2344 TMC Support Equipment

SPATIAL LIGHT MODULATORS

INSTALLATION MANUAL. ST-CVTMD420-WPIR-W Covert Motion Detection Color Camera. v1.3 8/11/11 1

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

SC24 Magnetic Field Cancelling System

Nanotechnology Solutions Partner

Asylum MFP-3D Standard Operating Procedures

Asylum MFP-3D Standard Operating Procedures

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

-Technical Specifications-

V9A01 Solution Specification V0.1

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

SC24 Magnetic Field Cancelling System

Nanotechnology Solutions Partner

EMC-Scanner. HR-series

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Scanning For Photonics Applications

In-process inspection: Inspector technology and concept

MachineryMate 800 operating guide Handheld vibration meter

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Portable Otoacoustic Emission Screener [Under Buyback]

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Nanotechnology Solutions Partner

CBF500 High resolution Streak camera

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

No. MME/INS/153/ Date: 27 August 2018 NOTICE INVITING TENDER

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

OPTICAL POWER METER WITH SMART DETECTOR HEAD

HD-CM HORIZON DIGITAL CABLE METER

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

The BUMA. Available Models: Standard Definition Models BUMA-SD18 BUMA-SD26 BUMA-SD40

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Press Publications CMC-99 CMC-141

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Purchasing Department Finance Group INVITATION TO BID

GFT Channel Digital Delay Generator

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

111 Highland Drive Putnam, CT USA PHONE (860) FAX (860) SM32Pro SDK

Do not disassemble any part of the device! Disassembling of the product is permitted only for experts certified with the NT-MDT company.

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

FLAT DISPLAY TECHNOLOGY

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Transcription:

EXPRESSION OF INTREST No. IITDh/GA/CRF/2018-2019/02 EXPRESSION OF INTEREST (EoI) FOR PROCUREMENT of HIGH RESOLUTION ATOMIC FORCE MICROSCOPE (AFM)/SCANNING PROBE MICROSCOPE AS PER ANNEXURE-I

1. Introduction IIT Dharwad is an Institute of National Importance created by an Act of Parliament in 2016. IIT Dharwad has been steadily establishing its operations in its transit campus. Simultaneously, the institute is employing bright young and accomplished faculty. A number of unique research and development programs are on the anvil. The institute now needs to raise the levels of the capacity with the best of the facilities and infrastructure. This will provide highly talented and accomplished faculty to pursue not only their research but also think of innovative way of introducing instructional/teaching/learning solutions to practical problem of the students. 2. Objective The objective of this invitation of Expression of Interest (EoI) is to seek responses from eligible Vendors for SUPPLY, INSTALLATION, COMMISSIONING, DEMONSTRATION and TRAINING OF High Resolution Atomic Force Microscope (AFM)/Scanning Probe Microscope as per Annexure-I 3. Timelines 3.1 Major activities in the procurement process will be as given below: - Sl No Activity Remarks (a) Pre-Bid Meeting To clarify the issues/ queries raised by intrested firms facilitate submission of bids. (b) Deadline for submission of EoI Till 10.00 Hrs on 03/10/2018 (c) Issue of Tender Document Only to the vendors who submit the response to the EoI. Link for downloading the tender document to such vendors will be sent via e-mail on 04/10/2018 (c) Submission of Tender Documents Deadline for bid submission 17/10/2018, 16.30 hrs based on updated specifications and tender document (d) Evaluation of Technical Bids About 3 weeks (Tentative) (e) Opening of Commercial Bids The shortlisted bidders will be intimated by e-mail the schedule of opening of the commercial bids (f) Award of Contract The selected vendor will be awarded the contract.

4. MATERIAL DESCRIPTION High Resolution Atomic Force Microscope (AFM)/Scanning Probe Microscope as per specifications described below in Annexure-I 4.1 Annexure-I The single Scanning Probe Microscopy (SPM) system must be capable to address all major applications required for the analysis of samples in the field of Materials Science, Semiconductor Technology, Ceramic and Polymers. The SPM/AFM must be the state of art machine with the capacity of analyzing conducting and non-conducting nanomaterials. The system should consist of The SPM/AFM scan engagement mechanism must be automated, vertical, and fully software controlled. The SPM/AFM must have a tip-scanning configuration, The system must have a minimum amount of cables from the scanning Probe Microscopy (SPM) controller to the SPM/AFM head The SPM must include top-view optics, with an unobstructed optical path between optics & AFM cantilever. Complete Atomic Force Microscope system must be capable to scan small, medium and large size samples with zero background noise. System must include a general purpose imaging mode with all of the following features: 1. Automatic optimization of critical imaging parameters including setpoint, gains, scan rate and Z limit 2) The SPM/AFM system does not manually require that the cantilever resonance to be tuned 3) Mode automatically compensates for drift of the deflection signal Must come with motorised and independent x, y, and z stage with automated tip approach, focus and stage control Sample up to 50 mm x 50 mm and 20 mm thickness should be accommodated (XYZ) Preferably Integrated Acoustic Enclosure and Active Vibration Isolation system needs to be quoted and shipped along with the system Supply of a complete 3D Scanning System with accessories for high resolution imaging

Modes of Operation The system must include the following scanning modes: 1. AFM Contact Mode 2. AFM True Non-Contact Mode 3. AFM Tapping Mode 4. Lateral Force Microscopy 5. Phase Imaging 6. Force Modulation Microscopy 7. Scanning tunneling Microscopy 8. Magnetic force microscopy 9. Force Distance (F-D) Spectroscopy with mechanical properties like Adhesion, elasticity, Young s modulus to be offered. 10. Electrical modes such as EFM, KPFM with external high voltage up to 150 V or higher 11. Photo-current mapping 12. Variable Gain Conductive Modes Scanners The quoted system should be compatible to use one or more Scanner to cover from large area to smallest possible areas with the best possible resolution as given below. The AFM system scanner design must be capable to eliminates artifacts in the images by keeping the relative position of the laser spot fixed in relation to the cantilever throughout the scan cycle. (Technical justification / explanation to be provided). The XY scanner and Z scanner should have both open loop and closed-loop feedback system. The scanner must have a XY axes scanning range 50 µm, and Z axes scanning range 10 µm. The X, Y, Z scanner design should be flexure hinge type, the movement of X-Y-Z scanner should be completely separated from each axis and independent from other axis movement. The XY scanner must have resolution of 0.1 nm or better The Z scanner must have scan resolution of 0.02 nm or better. The SPM system must ensure a constant tip-sample distance is maintained in noncontact mode without damaging the tip or sample. The Z scanner must have high feedback speed with resonant frequency 9 khz or better. Motorized stage (XY) programmable for multi-site measurements Integrated stage control for fast sample navigation. The scanner should be with Piezo sensors in all X, Y, and Z. The quoted scanner must support all imaging modes as required.

AFM Tips/Probes/Ca ntilevers Suitable Cantilevers should be offered for all the modes quoted. (Detailed technical specifications of all the tips/probes are to be provided Probe tip exchange must be very convenience without requiring special tools or head removal. The AFM system should allow user to mount cantilever purchased from 3 rd party Calibration AFM calibration kit with necessary standard calibration samples (HOPG, Mica ) and other tools must be provided System Optics AFM scanning cantilever/probe optical surface should be viewable on axis in real time via Direct Optical Video Access by CCD. The Field-Of-View (FOV) must be software controlled zoom and cover the range from 1465 µm down to 180 µm or better. The resolution of the optics must be 1 µm or better. The AFM must include top-view optics with motorized focus & digital zoom. The optics must have software-controlled white LED illumination. The optics must include a 5-Megapixel or higher camera, and software to display and store the optical image from within the AFM software. System controller The system must provide the capability to calibrate the cantilever spring constant by thermal tuning of the cantilever. It must be produce data sets with minimum 5,000 x 5,000 pixel ( or better) density for all channels. Enables simultaneously acquisition of 16 or more images. The system must allow for up to 8 simultaneous channels in real time scanning. It must be support use of micro actuated cantilevers for fast scanning. It must be provide fully software-controlled, digital Q-control of the cantilever s. It must be allow customizable input/output signal paths through a signal access module integrated inside the controller with BNC connector whose function is softwareselectable. Must provide at least 3 user accessible lock-in amplifiers The electronic signal inputs should be at least 18 channels of 24 bit ADC. The electronic signal output should be at least 12 channels of 20 bit DAC. It must be provide real time adjustment to all scanning parameters scan rate, scan size, scan offset, gains and others. It must be include an intuitive, easy-to-follow graphic user interface for beginners, which automatically adjusts the scanning parameters (including gains, scan speed, set

point,..) without user interaction. The AFM controller should have built in signal access port, i.e. Pixel, line, Frame, NCM mode, AC mode etc. Light source /Detector Appropriate laser light source, Detailed Instruction Manuals must be supplied with the instruments Four Quadrant (or better) position sensitive photo detector Data acquisition and image processing software The AFM system should have software for multiple data acquisition and display. Able to perform multi-tasking with Microsoft windows based data acquisition or equivalent, optical view and for imaging processing, analysis and presentation for all modes in SPM/ AFM should be provided Should facilitate seamless data transfer to the analysis software Image analysis software and features a). Cross section analysis b). Roughness measurement c). Grain size analysis d). Depth analysis e). Power spectral analysis f). Histogram analysis g). Fractal analysis h). Fourier analysis i). Image mixing j). Auto-correlation k).enhanced image filtering tools Image modification and presentation software & features a). Force-distance curve analysis b).2d Fast Fourier analysis c). Plane-fit d). High pass and low pass filters e). Zoom in/out f). Optional grid on images and curves g). Variable shading and display angle, tilt h). Color bar completely user definable 2D and 3D height presentation

i). Menu for image series presentation Image and data export format at least a) Export to BMP, JPG, TIFF b) Export to ASCII format and MatLab c) Must include automated system configuration for operation in liquids to operate these modes by one mouse click d) Must include automated system configurations for advanced modes like SKM, MFM etc e) Software must be a sole package for all modes and attachments with no need for additional software programs. f) Software package must include both image acquisition and data processing software in one package with no need for different programs operation. g) Software must be free-for copy, e.g., can be installed on unlimited number of off-line PC Computer with Monitor The system must have SPM /AFM compatible latest version high performance computer with Intel i7 processor or better and Windows based operating system, LED 24 or higher monitor, sufficient number of USB port, 8GB RAM, DVD RW, Mouse, Keyboard, etc. Appropriate cables and power cables to be provided. Others Please specify any other technical details (if any) which has not been covered above but is/are part of the system Power supply and back up The instrument and computer should be compatible with the power supply specification in India, 220V, 50/60 Hz, (Operating range 210-240 V) Suitable UPS providing 1 hour or more backup with PANASONIC Batteries should be included Installation and training The system must be installed, and demonstrated by factory trained service engineers at our site free of charge; Comprehensive on-site training required to our satisfaction Warranty and Support a. Three years comprehensive warranty (not including the down time) must be included along with the bid/offer separately. b. Warranty should start from date of installation. c. Service response time, turn-around time & up-time of the equipment should be

clearly specified. d. Service response time must be 48 hours. e. The AFM must have provision for on-line diagnosis of faults. f. Must provide one-time free shifting and re-installation of the system from the transit campus to the permanent campus of IIT Dharwad Required Documents along with technical specifications For the equipment quoted, the supplier must provide: a. List of at least 3 users in India, with (exactly) similar systems installed preferably in last 5 years. b. The name(s) of the service engineer(s) employed by them who is/are competent to service the equipment being quoted with their locations in India. c. The supplier should provide calibration/traceability certificate of the equipment as per National institute of Standards & Technology (NIST)/National Physical Laboratory (NPL) UK / United Kingdom Accreditation System (UKAS) preferably d. Detailed user instruction manual, operation/instruction manual, troubleshooting manual, CDROM tutorials for AFM e. Detailed circuit and fault diagnostic software, detailed circuit diagram of the equipment (AFM), maintenance and service manuals

DETAILS OF PRE-BID MEETING To clarify the issues/queries raised by intrested firms and to facilitate in submission of bids, the pre-bid meeting would be held as follows: Place Time Date Board Room, Admin Building, 11.00 am 04/10/2018 IIT Dharwad PROCEDURE FOR SUBMISSION OF RESPONSE TO THE EoI The response to the EoI should reach IIT Dharwad on or before 03/10/2018 by 10.00 hrs on the following address: The Officer on Special Duty (Admin, Finance & Contracts) P.B. Road, Near High Court, Dharwad-580011 Or can be forwarded by e-mail at pro@iitdh.ac.in on or before 03/10/2018 by 10.00 hrs. For any queries, you may reach us at 0836-2212839 Please acknowledge the receipt of this invitation for EoI Sd/- Officer on Special Duty (Admin, Finance & Contracts) IIT Dharwad