HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Similar documents
HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LED Driver Linear / area fixed output

LED Driver Linear / area dimming

LED Driver Compact dimming

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact dimming

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Constant voltage

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED Driver Compact dimming

LED control gear Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

LED Driver Compact dimming

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

Emergency lighting units EM powerled

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

Emergency lighting units EM powerled

OT 100/ /700 P5

OPTOTRONIC Intelligent

Indoor Linear 80W Driver SI-C215280N2KR

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

LED MODULES READYLINE DL

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

HID control gear Electronic

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

Technical Information

OPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.

Gamma instabus. Technical product information

DALI TOUCHPANEL BASIC TW. Operating and control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

Emergency lighting units EM INVERTER

Catalogue Ignitors and power switches for HID

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

QTi DALI 2X14/24/ DIM

KRF EMC Filters Installation, Operation and Maintenance Manual

ODW-621. RS-232 Point-to-point applications

15 Series - Dimmer

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

HELVAR. CONTROLLABLE ELECTRONIC BALLASTS DALI & 1-10 V controllable ballasts STANDARD ELECTRONIC BALLASTS

Datasheet - SRB301LC 24VAC/DC

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Generator protection relay

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

Benefits. Applications

LONWORKS Fibre Optic Router

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

Process transmitter RMA422

R xx-C0900-J074

Type Contact form Model

TOSHIBA Industrial Magnetron E3328

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

Fibre optic router for TP/FT-10 LRW-112PP

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

LONWORKS Fibre Optic Converter

EMC Solutions Noise filtering

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Programmable Power Supplies 188 W 384 W R&S HMP Series

Obsolete Product(s) - Obsolete Product(s)

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Ordering details. Approval. Classification

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

R Rxx-Vxxxx-L334-x

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

POWER. DA10-M Series. 10 Watts. Data Sheet. Total Power: 10 Watts Input Voltage: Vac # of Outputs: Single, 5 Volts SPECIAL FEATURES

K-BUS Dimmer Module User manual-ver. 1

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Fibre Optic Modem ODW-622

Rack mounted telephone- and leased line modem for industrial applications

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Linear flow control with actuator IFC

Modular pulse operated latching relay 16 A

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Fibre Optic Modem ODW-611

Figure 1: Device components

Operating instructions

Type: DILM25 10(24V50HZ) Article No.:

R&S RT-Zxx High-Voltage and Current Probes Specifications

Datasheet - SRB-E-201ST

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

QUICKTRONIC FIT 8. Product family datasheet. ECG for FL 26 mm

02/11/2015

Features. High Brightness SMD LED Light source

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Type: DILM12 10(24VDC) Article No.:

Linear flow controls VFC Linear flow controls with actuator IFC

QUICKTRONIC INTELLIGENT DALI DIM T8

Operating Instructions Dimmer for V Incandescent Lamps

QTi 2X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DIM T5 ECG dimmable 1 10 V for FL 16 mm. Areas of application.

Transcription:

Linear / area dimming Constant current LED driver DALI Dimmable Product description Dimmable built-in constant current LED Driver Adjustable output current between 1,050 and 1,750mA via DIP switch Max. output power 80 W Up to 91 % efficiency Power input on stand-by < 0.5 W Dimming range 1 100 % For luminaires of protection class I and protection class II Nominal life-time up to 100,000 h 5-year guarantee Benefits Application-oriented operating window for maximum compatibility Best energy savings due to low stand-by losses and high efficiency Long lasting and high reliability Slim white metal housing 30 x 21 mm Double output connectors (parallel connection) Suitable for emergency lighting units Interfaces DALI SwitchDIM (with memory function) Terminal blocks: 45 push terminals Applications Linear and area lighting Office industrial shop Approval marks In preparation, if not already printed on product label Subject to change without notice

Linear / area dimming Technical data Rated supply voltage AC voltage range DC voltage range Mains frequency Overvoltage protection Typ. current (at 230 V, 50 Hz, full load) Leakage current (at 230 V, 50 Hz, full load) 220 240 V 198 264 V 176 280 V 0 / 50 / 60 Hz 320 V AC, 48 h 299 407 ma < 550 μa Max. input power 90 W Typ. efficiency (at 230 V / 50 Hz / full load) 0.9 λ (at 230 V, 50 Hz, full load) 0.98 Typ. power input on stand-by < 0.5W Typ. input power in no-load operation n.aj In-rush current (peak / duration) 37A/168us Units:mm THD (at 230 V, 50 Hz, full load) < 5 % Time to light (at 230 V, 50 Hz, full load) < 0.6 s Time to light (DC mode) < 0.3 s DIP Switch Switchover time (AC/DC) Turn off time (at 230 V, 50 Hz, full load) < 0.3 s < 4 ms Output current tolerance ±5 % Output current ripple 2 < 5 % Max. output voltage (no-load voltage) 60 V Dimming range 1 100 % Mains surge capability (between L N) 1 kv Mains surge capability (between L/N PE) Surge voltage at output side (against PE) Dimensions L x W x H Ordering data Type Packaging carton 2 kv < 500 V 358x30x21 mm Weight per pc. 20 pc(s) 0.330 Kg ON OFF Specific technical data DIP Switch Output Min. Max. Min. Max. Typ. power Typ.current Type 1 2 3 4 5 6 current (ma) forward voltage (V) forward voltage (V) output power (W) output power (W) consumption (at 230 V, 50 Hz, full load) (W) consumption (at 230 V, 50 Hz, full load)(a) 1750 20 46 35 80.5 88.1 0.407 1700 20 47.5 34 80.75 88.4 0.407 1650 20 48.5 33 80.03 87.8 0.407 1600 20 50.5 32 80.8 88.4 0.407 1550 20 52 31 80.6 88.5 0.407 1500 20 54 30 81 88.7 0.407 1450 20 54 29 78.3 86.1 0.399 1400 20 54 28 75.6 82.8 0.386 1350 20 54 27 72.9 80.8 0.374 1300 20 54 26 70.2 77.1 0.361 1250 20 54 25 67.5 74.9 0.350 1200 20 54 24 64.8 71.9 0.334 1150 20 54 23 62.1 69.1 0.320 1100 20 54 22 59.4 66.5 0.308 1050 20 54 21 56.7 63.3 0.299 1Load switching on output side is safe but not permitted 2Valid at 100 % dimming level Subject to change without notice

1. Standards EN 55015 EN 61000-3-2 EN 61000-3-3 EN 61347-1 EN 61347-2-13 EN 62384 EN 61547 EN 62386-101 (according to DALI standard V1) EN 62386-102 EN 62386-207 According to EN 50172 for use in central battery systems According to EN 60598-2-22 suitable for emergency lighting installations 2. Thermal details and life-time 2.1 Expected life-time Type Output current ta 40 45 50 55 60 65 1,050-1,100 ma >1,100-1,400 ma >1,400-1,750 ma tc 60 65 70 75 80 85 Life-time >100,000 h >100,000 h >100,000 h >80,000 h >75,000 h >50,000 h tc 60 65 70 75 80 - Life-time >100,000 h >100,000 h >80,000 h >75,000 h >50,000 h - tc 60 65 70 75 - - Life-time >100,000 h >100,000 h >80,000 h >50,000 h - - The LED Driver is designed for a life-time stated above under reference conditions and with a failure probability of less than 10%. The relation of t C to ta temperature depends also on the luminaire design. 3. Installation / wiring 3.1 Circuit diagram switchdim DALI control 220-240V 50-60Hz 3.2 Wiring type and cross section Solid wire with a cross section of 0.5 1.5 mm². Strip 8 9 mm of insulation from the cables to ensure perfect operation of terminals Wire preparation: 0.5 1.5 mm² 8 9mm 3.3 Loose wiring Press down the push button and remove the cable from front. Subject to change without notice 3

Power Factor THD U out [V] Efficiency LED Driver 3.4 Wiring guidelines The cables should be run separately from the mains connections and mains cables to ensure good EMC conditions. The LED wiring should be kept as short as possible to ensure good EMC. The max. secondary cable length is 2 m (4 m circuit), this applies for LED output. Secondary switching is permitted. But the secondary switch may damage the LED modules, so it is not recommended to do so. The LED Driver has no inverse-polarity protection on the secondary side. Wrong polarity can damage LED modules with no inverse-polarity protection. Wrong wiring of the LED Driver can lead to malfunction or irreparable damage. 3.5 Hot plugging Hot plug-in is supported, but it may damage the LED modules due to residual output voltage is too high. 3.6 Earth connection The earth connection is conducted as protection earth (PE). The LED Driver can be earthed via earth terminal or metal housing. If the LED Driver will be earthed, protection earth (PE) has to be used. There is no earth connection required for the functionality of the LED Driver. Earth connection is recommended to improve following behavior: Electromagnetic interferences (EMI) LED glowing at stand-by Transmission of mains transients to the LED output in general it is recommended to earth the LED Driver if the LED module is mounted on earthed luminaire parts respectively heat sinks and there by representing a high capacity against earth. 4. Electrical values 60 55 4.1 Typical Opreating Window 0.95 4.2 Efficiency vs load 50 45 40 35 30 25 20 15 Dimming opreating area Rated opreating area 0 200 400 600 800 1000 1200 1400 1600 1800 0.90 0.85 0.80 0.75 1750mA 1400mA 1050mA 20 40 60 80 100 I OUT [ma] Output power [W] 1.00 0.95 4.3 Power Pactor vs load 4.4 THD vs load 8.00 6.00 1750mA 1400mA 1050mA 0.90 4.00 0.85 0.80 1750mA 1400mA 1050mA 20 40 60 80 100 Output power [W] 2.00 0.00 20 40 60 80 100 Output power [W] Subject to change without notice 4

4.5 Maximum loading of automatic circuit breakers typ. Number of ECG at one singlepole Type circuit breaker (CB) Ipeak /Δt 10 A 16 A 20 A 25 A CB-Typ B 7 9 12 15 37A/168us C 11 15 20 25 Data for Usupply = 230 VAC, mains impedance = 1 Ω In case of multi-polar CB the maximum number is reduced by 20 % The max. number may differ depending on CB manufacturer. Please consider the specifications of the manufacturer. Basically, CB with C-characteristics are recommended to be used in lighting groups. Ipeak 1/2 Ipeak Δt Typical current - time profile when switching on 4.6 Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % THD 3. 5. 7. 9. 11. <5 <3 <2 <3 <2 <2 4.7 Dimming 4.5 Dimming characteristics Dimming range 1 % to 100 % Digital dimming value Digital control with: DALI signal: 16 bit Manchester Code Speed 1 % to 100 % in 0.2 s Programmable parameter: Minimum dimming level Maximum dimming level Default minimum = 1 % Programmable range 1 % MIN 100 % Default maximum = 100 % Programmable range 100 % MAX 1 % Dimming curve is adapted to the eye sensitiveness. Dimming is realized by amplitude dimming. 260 240 220 200 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 Relative lighting level % Dimming characteristics as seen by the human eye 5. Interfaces / communication 5.1 Control input (DA/N, DA/L) Digital DALI signal or switchdim can be wired on the same terminals (DA/N and DA/L).The control input is non-polar for digital control signals (DALI). The control signal is not SELV. Control cable has to be installed in accordance to the requirements of low voltage installations. Different functions depending on each module. 5.2 SwitchDIM Integrated switchdim function allows a direct connection of a pushbutton for dimming and switching. Brief push (< 0.6 s) switches LED Driver ON and OFF. The dimming level is saved at power-down and restored at power-up. When the pushbutton is held, LED modules are dimmed. After repush the LED modules are dimmed in the opposite direction. In installations with LED Drivers with different dimming levels or opposite dimming directions (e.g. after a system extension), all LED Drivers can be synchronized to 50 % dimming level by a 10 s push.use of pushbutton with indicator lamp is not permitted. Subject to change without notice 5

6. Functions 6.1 Function: adjustable current Adjustable output current between 1,050 and 1,750 ma via DIP switch. 6.2 Short-circuit behavior In case of a short circuit on the output side (LED) the LED Driver switches off. After elimination of the short-circuit fault the LED Driver will recoverauto matically. 6.3 No-load operation The LED Driver works in burst working mode to provide a constant output voltage regulation which allows the application to be able to work safely when LED string opens due to a failure. 6.4 Overload protection If the output voltage range is exceeded the LED Driver will protect itself and LED may flicker. After elimination of the overload, the nominal operation isrestored automatically. 6.5 Over temperature protection The LED Driver is protected against temporary thermal overheating. If the temperature limit is exceeded, the Driver switch off. It restarts automatically.the temperature protection is activated typically at 10 C above tc max. 6.6 Software / programming Programming of ECG is done via the DALI interface by using the Interface DALI USB and the PC Software. Tridonic DALI-USB Interface and Software masterconfigurator are recommended. 7. Miscellaneous 7.1 Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal.the isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). 7.2 Storage conditions Environmental conditions: 5 % up to max. 85 %,not condensed(max. 56 days/year at 85 %) Storage temperature: -40 C up to max. +80 C The devices have to be acclimatized to the specified temperature range (ta)before they can be operated. 7.3 Additional information China Add.: Shenzhen Hengyao Lighting Technology Co., Ltd. 3/F,Yinshan Building,Huaide,Baoan District, Shenzhen P.R. China. Tel: +86 755 2777 2329 E-Mail: hygd@hengyao.com Germany Add.: Lence Technologie GmbH Pallaswiesenstr. 182 64293 Darmstadt Tel: +49 (0) 6151 8602 652 E-Mail: info@lence-tech.com 3AAA and the 3AAA logo are trademarks or registered trademarks of hengyao. Information in this document supersedes and replaces all information previously supplied. The 3AAA logo is a registered trademark of Hengyao. All other names are the property of their respective owners. 2017 Hengyao - All rights reserved Subject to change without notice 6