UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Similar documents
SCALE & WEIGHT DISPLAYS

DPM OWNERS MANUAL Website: Phone: (800)

LAUREL ELECTRONICS, INC.

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

MICRO SERIES COUNTERS & TIMERS LARGE DIGIT MODEL

DCP100 Digital Control Programmer Specifications

263 Series LED Bargraph Indicator and Controllers

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Process Transmitter RMA 422

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

Eaton Durant. Counters, process instruments and hour meters.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Operating instructions Electronic preset counter Type series 717

Set Point Controller OC557. Operator s Manual

Solution Selection Guide

Micro-DCI 53ML5100 Manual Loader

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Process transmitter RMA422

16-BIT LOAD CELL/DUAL STATUS INPUT

Multifunction Digital Timer

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

HOBO H Energy Logger

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Preset counters, electronic

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Model IQ4-PC User Manual Revision Date:

Pen and Multichannel Recorder: Digital Display

Global Water Instrumentation, Inc.

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Hour Meters / Timers, electronic

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

multi-function meters

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Multifunction devices

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Operating Instructions

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

Hybrid Chart Recorder 250 mm (10")

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

DPR100 C/D Pen and Multichannel Recorder: Digital Display

Solid-State Digital Timer

02/11/2015

CARLO GAVAZZI Automation Components

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Electronic Pulse Counter Combination device

P6000A/P5000. Programmable Counter/Timer. NEWPORT Electronics, Inc. Operator s Manual

Type MG-6 Auxiliary Relay Class 1E

EasyReader Model ER4C

We put you first. And keep you ahead. USES FEATURES. Bulletin SS09040 Issue/Rev. 0.2 (10/14)

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

K3NX Process Meter OPERATION MANUAL

BE3-GPR GENERATOR PROTECTIVE RELAY

OWNERS MANUAL LUNATEC V3 MICROPHONE PREAMPLIFIER AND A/D CONVERTER

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

TABLE OF CONTENTS. Instructions:

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

DA E: Series of Narrowband or Wideband Distribution Amplifiers

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

EasyReader Model ER2C

Special Applications Modules

DA : Series of Narrowband or Wideband Distribution Amplifiers

INTRODUCTION / DESCRIPTION. Description

INT-C and INT-F. London Electronics Limited. Panel mounting counter / ratemeter. Connection details, scaling and general information

Wall-/Pipe-Mount Level Indicator

201AN DC VOLTMETER 201AN-AC VOLTMETER

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

SIGNET 5500 Flow Monitor ENGLISH

A MISSILE INSTRUMENTATION ENCODER

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

PB-507. Advanced Analog & Digital Electronic Design Workstation Instruction Manual. Revision: 2/2014

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

Operating Instructions

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

JENCO ELECTRONICS, LTD.

Flexible Counter Series in DIN size 24 x 48 mm

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Flexible Counter Series in DIN size 24 x 48 mm

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Advanced Test Equipment Rentals ATEC (2832)

actions. 12 digital outputs can be assigned to 4 different types of events (MODE, Alarm, Time and PV) 32 Programs, 800 segments

1900/25 Vibration Monitor

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

Transcription:

99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell UNIVERSAL DIGITAL COUNTER Frequency and Period Rate and Total Integration and Square Root Quadrature and more Selector Guide interface or control Precision panel instrumentation with analog, digital and pulse inputs for indication, data PLUG-IN OPTIONS Universal Power Supplies Analog Outputs 0-20 madc and 0-10 VDC Digital Interface: RS-232, RS-485, BCD Dual Setpoint Controller

800 Plus UNIVERSAL DIGITAL METERS & COUNTERS Model Type: 800 Plus Universal Digital Meter 800 Plus Universal Counter Selector guide and price: page 3 page 4 page 5 page 6 page 7 Specifications DC Volt & Amp AC Volt & Amp RTD Temperature Thermocouple Process Monitor Strain Gauge Load Cell FR Counter/Timer VF Counter/Timer QD Quaduture Input Display: 7-segment LED, 14.2mm,.56 high digits Number of digits 5 digits 6 digits Range -99999 to +99999-999999 to +999999 LED indicators 2 status indicators 3 status indicators Color R e d o r G r e e n a v a i l a b l e w i t h a l l m o d e l s Accuracy (25 C): ANSI TC type K Full scale or reading 0.01%FS 0.1%FS 0.04 C 0.1 C 0.01%FS 0.01%FS 0.01%FS ±2ppm 0.015% ±2ppm ± number of counts 1 1 - - 1 1 1 Span TEMPCO 0.003% of reading/ C- except load cell(0.0015% rdg./ C) & FR(±1ppm/ C typical) Zero TEMPCO 0.1 counts/ C 0.001FS/ C Conversion: Patented A/D conversion method (US patent no. 5,262,780) 1 / period time: Update rate 60/sec. @ 60Hz operation; 50/sec. @ 50 Hz operation Gate time + 30ms + 2 periods of Output update rate (UDM) 56/sec. @ 60Hz operation; 47/sec. @ 50 Hz operation the input signal (max): gate time Display update rate (UDM) 3.5/sec. @ 60Hz operation; 3/sec. @ 50Hz operation selectable 0 to 199.99 seconds Noise rejection: Common Mode voltage from DC to 60 Hz safety rated to 250 VAC; 4.2 kvp per high voltage test CMR (DC to 60 Hz) 130 db - NMR (50/60 Hz line) 90 db with minimum filtering - Case: NEMA 4 (IP65) 1/8 DIN case made of high impact 94V-0 UL rated plastic Environmental: Temperature: Operating 0 C~55 C, Storage -40 C~85 C; Relative humidity 95% at 40 C non-condensing Operating Power: Frequency 47 to 440 HZ and DC, consumption 5.3 Watts maximum Standard Universal power supply 85 to 264 VAC, 90 to 370 VDC Option Universal power supply 8 to 28 VAC, 9 to 37 VDC Excitation: Selectable with shorting jumpers on power supply printed circuit board (normal setting 10 VDC) Outputs 5 VDC, ±5%, 100 ma max., 10 VDC, ±5%, 120 ma max., 24 VDC, ±5%, 50 ma max. Isolation (power ground) Safety rated to 250 VAC, 4.2 kv peak per high voltage test Dual Controller option: Power is provided by meter, update rate is 56 / second at 60 Hz, 47 / second at 50 Hz Setup Setpoint values may be entered from front panel pushbutton or via RS-232 or RS-485 Output operation Either may be set to operate above or below setpoint, latching or non-latching, or output disabled Filtering Comparison to the setpoints may be from filtered or unfiltered input signal Time delay Selectable time delay of output status change from 1 to 128 readings Lockouts Pushbutton control of display and change of setpoints, or display of setpoints, or disable Alarm status indicators Either of two red LED s may be set to indicate when output is on or off, or they may be disabled Relay output: 10 A at 240 VAC, 8 A at 24 VDC contact rating; safety certification: VDE, UL, CSA Isolation Coil to contacts :Safety rated to 250VAC, 4.2 kv peak; Between open contacts : Withstand 1 kvrms Response to input signal Pick-up: 26 milliseconds typical; Release: 22 milliseconds typical Optotransistor output: Voltage rating: 30VDC; Current rating: 100 ma minimum at 1.2 VDC maximum Isolation Safety rated to 250 VAC, 4.2 kv peak per high voltage test Response to input signal 17 milliseconds typical Analog output option: Power : provided by meter, Isolation: Withstand 3750 Vrms, 8mm creepage Accuracy Use basic meter accuracy ±0.05% of analog output full scale Response time 17 milliseconds for unfiltered input, same as basic meter for filtered output RS-232 / RS-485 option: Power : provided by meter; Isolation: safety rated to 250 VAC, 4.2 kvp per high voltage test Baud rates 300, 600, 1200, 2400, 9600, 19200 Type / Signal levels Full duplex (RS-485) / meets RS-232 and RS-485 standards BCD output option: Power : provided by meter; Isolation: safety rated to 250 VAC, 4.2 kvp per high voltage test Type / Signal levels Tri-state, stored parallel / LSTTL, CMOS compatible Controls BCD Enable, Hold, Data ready 2

800 Plus DC VOLTS and AMPS 1 2 3 4 1 Basic DPM, display & power supply: 810 Green LED display, 85~264 VAC, 90~370 VDC... 811 Green LED display, 8~28 VAC, 9~37 VDC... 820 Red LED display, 85~264 VAC, 90~370 VDC... 821 Red LED display, 8~28 VAC, 9~37 VDC... 0... 01 Adjustable analog output range of 0-20 ma and 0-10 V... 10 Dual Form C, 10 Amp relays... 11 Dual Form C, 10 Amp relays & analog output 0-20 ma and 0-10 V... 4 Input range options: DCV1 200.00 mvdc... DCV2 2.0000 VDC... DCV3 20.000 VDC... DCV4 200.00 VDC... DCV5 660.0 VDC... DCA1 2.000 madc... DCA2 20.000 madc... DCA3 200.00 madc... DCA4 5.000 ADC... Ordering Example: Model 821-00-0-DCV3 has red LED display with 8~28 VAC, 9~37 VDC power and 20.000 VDC input range. The 800 Plus Universal Digital Meter is a versatile, cost effective solution to a wide variety of monitoring and control applications. The input can be changed by the user to any of the DC voltage and current values listed above by re-locating shorting jumpers on the plug-in signal conditioner card. No calibration equipment is required when changing ranges since they are digitally precalibrated at the factory. Rescaling is accomplished via front panel pushbuttons. Optional alarms and outputs are also front panel programmable. Refer to product bulletin 800SP-A for complete specifications and description of all features. 3

800 Plus UNIVERSAL DIGITAL METER RMS VOLTS and AMPS 1 2 3 4 1 Basic DPM, display & power supply: 810 Green LED display, 85~264 VAC, 90~370 VDC... 811 Green LED display, 8~28 VAC, 9~37 VDC... 820 Red LED display, 85~264 VAC, 90~370 VDC... 821 Red LED display, 8~28 VAC, 9~37 VDC... 00 None... 01 Adjustable analog output range of 0-20 ma and 0-10 V... 10 Dual Form C,10 Amp relays... 11 Dual Form C,10 Amp relays & analog output 0-20 ma and 0-10 V... 4 AC input: RMV1 200.00 mvac... RMV2 2.0000 VAC... RMV3 20.000 VAC... RMV4 200.00 VAC... RMV5 660.0 VAC... RMA1 2.000 maac... RMA2 20.000 maac... RMA3 200.00 madc... RMA4 5.000 AAC... Ordering Example: Model 821-10-1-RMV5 has red LED display with 8~28 VAC, 9~37 VDC power, dual 10A relay outputs, RS-232 digital interface and 660.0 VAC input range. The 800 Plus Universal Digital Meter is a versatile, cost effective solution to a wide variety of monitoring and control applications. The input can be changed by the user to any of the RMS voltage or current values listed above by re-locating shorting jumpers on the plug-in signal conditioner card. No calibration equipment is required when changing ranges since they are digitally precalibrated at the factory. Rescaling is accomplished via front panel pushbuttons. Optional alarms and outputs are also front panel programmable. Refer to product bulletin 800SP-A for complete specifications and description of all features. 4

800 Plus RTD and THERMOCOUPLE 1 2 3 4 1 Basic DPM, display & power supply: 810 Green LED display, 85~264 VAC, 90~370 VDC... 811 Green LED display, 8~28 VAC, 9~37 VDC... 820 Red LED display, 85~264 VAC, 90~370 VDC... 821 Red LED display, 8~28 VAC, 9~37 VDC... 00 None... 01 Adjustable analog output range of 0-20 ma and 0-10 V... 10 Dual Form C, 10 Amp relays... 11 Dual Form C, 10 Amp relays & analog output 0-20 ma and 0-10 V... 4 Temperature Type: P385C Pt100 Ohm RTD DIN -202 to 850 C... P385F Pt100 Ohm RTD DIN -331 to 1562 F... P392C Pt100 Ohm RTD ANSI -202 to 850 C... P392F Pt100 Ohm RTD ANSI -331 to 1562 F... JC J Thermocouple -210 to 760 C... JF J Thermocouple -347 to 1400 F... KC K Thermocouple -244 to 1372 C... KF K Thermocouple -408 to 2501 F... TC T Thermocouple -257 to 400 C... TF T Thermocouple -430 to 752 F... EC E Thermocouple -240 to 1000 C... EF E Thermocouple -400 to 1830 F... SC S Thermocouple -46 to 1768 C... SF S Thermocouple -51 to 3213 F... RC R Thermocouple -45 to 1768 C... RF R Thermocouple -49 to 3214 F... Ordering Model 820-00-2-P392F has red LED display with 85~264 VAC, 90~370 VDC power, Example: RS-485 digital interface and ANSI Pt100 Ohm RTD input range of -331 to 1562 F The 800 Plus Universal Digital Meter inputs can be changed by the user to any of the RTD or thermocouple values listed above by re-locating shorting jumpers on the plug-in signal conditioner card. No calibration equipment is required. Refer to product bulletin 800SP-A for complete specifications and description of all features. 5

800 Plus UNIVERSAL DIGITAL METER PROCESS INPUTS, LOAD CELL, STRAIN GAUGE 1 2 3 4 1 Basic DPM, display & power supply: 810 Green LED display, 85~264 VAC, 90~370 VDC... 811 Green LED display, 8~28 VAC,9~37 VDC... 820 Red LED display, 85~264 VAC,90~370 VDC... 821 Red LED display, 8~28 VAC, 9~37 VDC... 00 None... 01 Adjustable analog output range of 0-20 ma and 0-10 V... 10 Dual Form C, 10 Amp relays... 11 Dual Form C, 10 Amp relays & analog output 0-20 ma and 0-10 V... 4 Signal Input: P Process monitor 4-20 madc = 0-10000 on display... P1 Process monitor with custom scaling (specify input/display SG Strain gauge (4 wire ratio) 0 to 200 mv = 0 to 20000. SG1 Strain gauge w/custom scaling (specify inputs/display rdgs) WM1 Load cells (6 wire ratio) specify inputs/display rdgs/excitation Ordering Example: Model 811-10-1-P1 has green LED display with 8~28 VAC, 9~37 VDC power, dual 10 A relay outputs, RS-232 digital interface and customer specified input range of 4-20 madc = 0 to 1600.0 on display The 800 Plus Universal Digital Meter is a versatile, cost effective solution to a wide variety of monitoring and control applications. The input can be changed by the user to other values within each signal input category above by re-locating shorting jumpers on the plug-in signal conditioner card. No calibration equipment is required when changing ranges since they are digitally precalibrated at the factory. Rescaling is accomplished via front panel pushbuttons. Optional alarms and outputs are also front panel programmable. Refer to product bulletin 800SP-A for complete specifications and description of all features. 6

UNIVERSAL DIGITAL COUNTER 800 Plus FREQUENCY, RATE, TOTAL, TIMER 1 2 3 4 1 Counter, display & power supply: 850 Basic counter, green LED display, 85~264 VAC, 90~370 VDC... 851 Basic counter, green LED display, 8~28 VAC,9~37 VDC... 860 Basic counter, red LED display, 85~264 VAC,90~370 VDC... 861 Basic counter, red LED display, 8~28 VAC, 9~37 VDC... 870 Extended counter, green LED display, 85~264 VAC, 90~370 VDC... 871 Extended counter, green LED display, 8~28 VAC,9~37 VDC... 880 Extended counter, red LED display, 85~264 VAC,90~370 VDC... 881 Extended counter, red LED display, 8~28 VAC, 9~37 VDC... 00 None... 01 Adjustable analog output range of 0-20 ma and 0-10 V... 10 Dual Form C, 10 Amp relays... 11 Dual Form C, 10 Amp relays & analog output 0-20 ma and 0-10 V... 4 Counter inputs: FR AC, pulses from transistors, contact closures, magn. pickup VF1 Analog to frequency converter (4-20 ma)... VF2 Analog to frequency converter (0-1 ma)... VF3 Analog to frequency converter (0-10 V)... VF4 Analog to frequency converter (special range-contact factory) QD Differential or single-ended inputs from quadrature encoders Ordering Example: Model 861-20-0-FR has red LED display with 8~28 VAC, 9~37 VDC power, open collector output and dual channel counter/timer function. Basic Counter Type Extended Counter Frequency, rate, total (up or down), period (2 channels simultaneously), time interval A to B, square root of rate. Rate, square root of rate (differential pressure or targettype flow meters). FR VF Basic counter plus rate & total simultaneously, linearize non-linear inputs, ratio, draw, arithmetic function(a * B, A / B, A + B, A B), phase angle, stop watch, up/down counting, batch counting. Basic counter plus rate and total simultaneously, linearize non-linear inputs, batch counting, 1 / rate (time). Position or length from encoders. Accepts differential or single-ended inputs. 1x, 2x, or 4x inputs. Z channel inputs. QD Note: Refer to product bulletin 800SP-A for complete details and specifications. Extended counter not required for QD applications 7

48mm (1.89in.) 4mm (.157in.) 102mm (4.02in.) 45 + 0.6/-0.0mm (1.772 +.024/-0.0in.) Panel Mounting and Cutout Ensure the O-ring is in place. Turn the two mounting screws counterclockwise until the space between the mounting pawl and the bezel is greater than the panel thickness. Insert the meter in the panel cutout. Turn the mounting screws clockwise until the meter is securely mounted in the panel. Do not overtighten the mounting screws. 96mm (3.78in.) FRONT VIEW J1 J2 J3 J4 J5 TOP VIEW J1 J2 J3 J4 J5 REAR VIEW 92 + 0.8/-0.0mm (3.622 +.032/-0.0in.) PANEL CUTOUT 10mm (.394in.) 800 Plus UNIVERSAL DIGITAL METER & COUNTER Front Panel Setup Keys MENU KEY The menu key steps through the various meter parameters that may be selected. These menu items may be locked out from front panel selection by software and hardware. PEAK DISPLAY KEY (DIGIT SELECT) In the Operating Mode, pressing the Peak Display Key causes the peak value of the input signal to be displayed. Pressing the key again returns the display to the present value. In Menu Mode, the Digit Select Key (Peak Display Key) is used to select input type and decimal point or to select one of the five display digits for programming. In the main menu, pressing the Digit Select Key causes the value or code that is stored for that menu item to be displayed and the left hand digit flashes. Each time the key is pressed, the next digit to the right will flash. The value of the flashing digit may be changed using the Value Select Key. In the Alarm Mode, pressing the Digit Select Key causes the most significant digit of the displayed setpoint value to flash. Digits are then selected the same as in the Menu Mode. Mounting Pawl RESET KEY (VALUE SELECT) In the Operating Mode, holding the Reset Key depressed and pressing any other key causes a reset to occur. The Menu Key resets all meter functions, the Alarm Key resets any alarm conditions and the Peak Display Key resets the peak value to present value. In the Menu Mode or Alarm Mode, the Value Select Key (Reset Key) sets the value of the flashing digit. Each time the key is pressed, the value increases by one. Holding the key down causes the digit to automatically step through the numbers. Connectors The 800 Plus Universal Digital Meter uses UL/VDE rated screw terminal connections that plug into the mating PC jack. Mounting Pawl ALARM KEY (REVERSE MENU) In the Operating Mode, pressing the Alarm Key displays the setpoint of Alarm 1 and then Alarm 2. These values may be changed using the Digit Select Key and the Value Select Key. In the Menu Mode, pressing the Alarm Key steps the display backward through the menu. Represented by: 800SG-01C