USER GUIDE IRLEDS SERIES - LED PAR PROJECTORS WITH INFRARED REMOTE CONTROL

Similar documents
6X3W TRICOLOUR LEDS COMPACT PROJECTOR

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

9X9W LEDS BLINDER WITH LCD DISPLAY USER GUIDE December 2013 Version 1.12

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

BATTERY-OPERATED WIRELESS PROJECTOR WITH RGB LEDS USER GUIDE July 2012 Version 1.0

7X15W 4-IN-1 LEDS ULTRA FAST MOVING HEAD WITH INFINITE RORATION MODE /ESC MIC ENTER USER GUIDE October Version 1

SPOT/FROST MOVING HEAD WITH PHILIPS MSD PLATINUM 5R LAMP. Evora. Flex5R USER GUIDE January 2015 version

Stratos Duo RGB. User Manual. Order code: EQLED371

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

ORDER CODE: EQLED65 USER MANUAL

Spectra Batten (Order code: LEDJ95)

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Fusion 120 Zoom. User Manual. Order code: EQLED068

Truss Light COB LED 30W

LIGHT COPILOT II. elationlighting.com Internet:

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

DMX LED light effect with 4 lenses

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

Owner Handbook. Jupiter Blackhole. LED UV Flood

Mini LED Pin Spot Light Model: PLS00571

SquareLED - Aura Bar & Matrix Beam Light 100

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

LED PAR 64 floor 12x8W RGBWAUV incl. remote

EPAR QW. User Instructions

TABLE OF CONTENTS INTRODUCTION

EPAR QA. User Instructions

Hex-color RGBAW+UV LED strip light

Opti Tri White Par. User Instructions

Ref. No.: LCB-48IP LED COLORUNIT 16X3W TRI DMX

MH-X50+ LED spot moving head. user manual

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

MHL-1410WISPOT 14X 10W QUAD DMX 2.4GHZ

Mini Stage Par 4 8W QCL RGBA/RGBW 25 /40 LED PAR. user manual

User Manual. Xstatic Pro, Inc Essex Street - Brooklyn, NY Version 1.2

Outdoor Stage PAR 12 4W Quad IR RGBW, 12 3W Quad IR UV LED PAR. user manual

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

American DJ. User Instructions. Model: Mega Bar 50RGB

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

Jelly Par Profile System Introduction Unpacking: Introduction: Customer Support: Warning! Caution! User Instructions

4LEDKIT-DJ USER MANUAL. LED Tricolor 4-PAR Lighting Kit. Please read this manual carefully and proper take care of this manual.

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

USER MANUAL MHL-10W-7-RGBW MKII

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

CU103 User Manual. Contents

LCB-320 LED COLORS 320X10MM DMX 16SEG

Ambient Temperature...3 Electromagnetic Compliance...3

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Package Contents Connections and Controls... 5 Front of the active Subwoofer... 5 Rear of the active Subwoofer... 6

Stage Wash 7x 10W LED Moving Head (RGBW)

LED Pot 12 1W RGBW LED PAR. user manual

LED Spere Direct Control 30 ORDERCODE 41125

PRODUCT SPECIFICATIONS

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

Crown FX PAR 77 LED spotlight. user manual

CYBER PAK. User Instructions.

LED Par 36 COB RGBW 12W, LED Par 46 COB RGBW 20W, LED Par 64 COB RGBW 60W, LED Par 56 COB RGBW 30W LED PAR. user manual

JunoScan MK-II LED scanner. user manual

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

LED Thunder S-150 Code 1097

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

1. Before you Begin Introduction Setup Operation Technical Information Technical Specifications...

LED Spot 300W. Please read this user manual before your operation

VRL PAR-1745 Par Lamp

Owner s Manual LED COMMANDER 16/2

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

LED Pixel Track Pro ORDERCODE 42205

Operating Instructions

2.0 Wall Mount TV Soundbar Instruction Manual

BROTHER, BROTHER & SONS

LED Pot 12 1W QCL RGB WW 15, LED Pot 12 1W QCL RGB WW 40 LED-PAR. user manual

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference.

DJ Lase BlueStar MK-II LED showlaser. user manual

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

ELED PAR RGB ZOOM. User Instructions. Elation Professional 6122 S. Eastern Ave. Los Angeles CA

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

USER S MANUAL

HEX16 Strip User Manual

SATRI AMPLIFIER AMP-51R. Owner s Manual

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

LED IP65 Slimline Par RGBWA +UV 7x12W

Glow P54 White LED Par

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

LED-BANK4 USER MANUAL. COLORbank 4

USER MANUAL Table of Contents

28 4K LED monitor. User Manual M284K

Owner Handbook Saturn Quad Beam. Owner Handbook. Saturn Quad Beam

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

LED Bar 240/8 RGB LED floodlight. user manual

MONOPRICE. SoftStage 80-Watt COB LED Stage PAR (RGB) with 30 and 80 Lenses. User's Manual P/N

CM-S38901SV TVL IR Long Range camera

Color Video Monitor. Instruction Manual. Read this manual thoroughly before use, and retain it for maintenance.

Transcription:

IRLEDS SERIES - LED PAR PROJECTORS WITH INFRARED REMOTE CONTROL USER GUIDE 9869/9870/9871/9872/9873/9874/9875/9876/9877/9878/9974/9975 - November 2012 Version 2.0

English irleds series - LED PAR projectors with infrared remote control 1 - Safety information Important safety information This unit is intended for indoor use only. Do not use it in a wet, or extremely cold/hot locations. Failure to follow these safety instructions could result in fire, electric shock, injury, or damage to this product or other property. This product contains non-isolated electrical components. Do not undertake any maintenance operation when it is switched on as it may result in electric shock. Any maintenance procedure must be performed by a CONTEST authorised technical service. Basic cleaning operations must thoroughly follow our safety instructions. WARNING : This unit contains no user-serviceable parts. Do not open the housing or attempt any maintenance by yourself. In the unlikely even your unit may require service, please contact your nearest dealer. In order to avoid any electrical malfunction, please do not use any multi-socket, power cord extension or connecting system without making sure they are perfectly isolated and present no defect. Warning This product is equipped with Class 2 LEDs. Please avoid looking directly at the beam as it may cause severe eye injuries. Risk of electrocution To prevent the hazard of electric shocks, do not use extension cords, multi-socket or any other connection system without making sure metal parts completely are out of reach. Recycling your device As HITMUSIC is really involved in the environmental cause, we only commercialise clean, ROHS compliant products. When this product reaches its end of life, take it to a collection point designated by local authorities. The separate collection and recycling of your product at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. Symbols used This symbol signals an important safety precaution. The CAUTION symbol signals a risk of product deterioration. The WARNING symbol signals a risk to the user s physical integrity. The product may also be damaged. Note : The legislation requires that every device set up in a public space features a double fixation bracket. This security system must hold 10 times the weight of the device. Page 2

irleds series - LED PAR projectors with infrared remote control English Instructions and recommendations 1 - Please read carefully : We strongly recommend to read carefully and understand the safety instructions before attempting to operate this unit. 2 - Please keep this manual : We strongly recommend to keep this manual with the unit for future reference. 3 - Operate carefully this product : We strongly recommend to take into consideration every safety instruction. 4 - Follow the instructions: Please carefully follow each safety instruction to avoid any physical harm or property damage. 5 - Avoid water and wet locations : Do not use this product in rain, or near washbasins or other wet locations. 6 - Installation : We strongly encourage you to only use a fixation system or support recommended by the manufacturer or supplied with this product. Carefully follow the installation instructions and use the adequate tools. Always ensure this unit is firmly fixed to avoid vibration and slipping while operating as it may result in physical injury. 7 - Ceiling or wall installation : Please contact your local dealer before attempting any ceiling or wall installation. 8 - Ventilation : The cooling vents ensure a safe use of this product, and avoid any overheating risk. Do not obstruct or cover these vents as it may result in overheating and potential physical injury or product damage. This product should never been operated in a closed nonventilated area such as a flight case or a rack, unless cooling vents are provided for the purpose. 12 - Cleaning precautions : Unplug the product before attempting any cleaning operation. This product should be cleaned only with accessories recommended by the manufacturer. Use a damp cloth to clean the surface. Do not wash this product. 13 - Long periods of non use : Disconnect the unit s main power during long periods of non use. 14 - Liquids or objects penetration : Do not let any object penetrate this product as it may result in electric shock or fire. Never spill any liquid on this product as it may infiltrate the electronic components and result in electric shock or fire. 15 - This product should be serviced when : Please contact the qualified service personnel if : - The power cord or the plug has been damaged. - Objects have fallen or liquid has been spilled into the appliance. - The appliance has been exposed to rain or water. - The product does not appear to operate normally. - The product has been damaged. 16 - Inspection/maintenance : Please do not attempt any inspection or maintenance by yourself. Refer all servicing to qualified personnel. 17 - Operating environment : Ambient temperature and humidity: +5 - +35 C, relative humidity must be less than 85% (when cooling vents are not obstructed). Do not operate this product in a non-ventilated, very humid or warm place.. 9 - Heat exposure : Sustained contact or proximity with warm surfaces may cause overheating and product damages. Please keep this product away from any heat source such as a heaters, amplifiers, hot plates, etc... 10 - Electric power supply : This product can only be operated according to a very specific voltage. These information are specified on the label located at the rear of the product. 11 - Power cords protection: Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at lugs, convenience receptacles and the point where they exit from the fixture. Page 3

English irleds series - LED PAR projectors with infrared remote control 2 - Main Features irled56-24x1rgbss : 24x1W RGB LEDs PAR56 projector, aluminium finish. irled56-24x1rgbsb : 24x1W RGB LEDs PAR56 projector, black finish. irled56-12x3tcss : 12x3W RGB LEDs PAR56 projector, aluminium finish. irled56-12x3tcsb : 12x3W RGB LEDs PAR56 projector, black finish. irled64-36x1rgbss : 36x1W RGB LEDs PAR64 projector, aluminium finish. irled64-36x1rgbsb : 36x1W RGB LEDs PAR64 projector, black finish. irled64-18x3tcss : 18x3W RGB LEDs PAR64 projector, aluminium finish. irled64-18x3tcsb : 18x3W RGB LEDs PAR64 projector, black finish. irled64-18x5tcss : 18x5W RGB LEDs PAR64 projector, aluminium finish. irled64-18x5tcsb : 18x5W RGB LEDs PAR64 projector, black finish. irled64-12x3tcss 25 : 12x3W RGB LEDs PAR64 projector, aluminium finish, beamwidth: 25. irled64-12x3tcsb 25 : 12x3W RGB LEDs PAR64 projector, black finish, beamwidth: 25. These products use the DMX, automatic and music-sensitives mode and are compatible with infrared remote controls. Features: - Aluminium housing - Double mounting brackets for suspension or ground handling - Rear display - Frost filters for perfect beam diffusions - Internal thermal protection Functions: Built-in command panel with digital drop-down display for : - DMX addressing - Choosing the number of channels: 2, 3, 4, 5 or 6 - Choosing the built-in programs - Choosing the preset colours - Master/Slave mode - Music-sensitive mode and choosing the mic sensitivity - Infrared remote control giving you access to every remote function Package contents: The package must contain: - The projector - The user guide - A double mounting bracket - An infrared remote control - A 2-pole + earth power cord 3 - Technical specifications 3.1 - irled56-24x1rgbss 3.5 - irled64-36x1rgbss Optical: - 24x1W LEDs 8 red, 8 green, 8 blue - Beamwidth: 30 Connectors: - DMX IN and OUT via 3-pin XLR, - POWER IN/OUT via IEC sockets Power supply: 110/240 V 50/60 Hz Power consumption: 30 W Finish: Aluminium Dimensions: 320 x 250 x 170 mm (PAR56 format) Weight : 2.7 kg Optical: - 36x1W LEDs 12 red, 12 green, 12 blue - Beamwidth: 30 Connectors: - DMX IN and OUT via 3-pin XLR, - POWER IN via 2P+E power cord Power supply: 110/240 V 50/60 Hz Power consumption: 40 W Dimensions : 340 x 270 x 220 mm (PAR64 format) Weight: 3.2 kg Page 4

irleds series - LED PAR projectors with infrared remote control English 3.2 - irled56-24x1rgbsb 3.6 - irled64-36x1rgbsb IrLED56-24x1RGBss with black finish IrLED64-36x1RGBss with black finish 3.3 - irled56-12x3tcss 3.7 - irled64-18x3tcss Optical: - 18x3W RGB LEDs - Beamwidth: 40 Connectors : - DMX IN and OUT via 3-pin XLR, - POWER IN/OUT via IEC sockets Power supply: 110/240 V 50/60 Hz Power consumption: 40 W Dimensions : 320 x 250 x 170 mm (PAR56 format) Weight : 2.8 kg Optique : - 18x3W RGB LEDs - Beamwidth: 40 Connectors : - DMX IN and OUT via 3-pin XLR, - POWER IN/OUT via IEC sockets Alimentation : 110/240 V 50/60 Hz Consommation : 60 W Dimensions : 340 x 270 x 220 mm (PAR64 format)) Poids : 4.3 kg 3.4 - irled56-12x3tcsb 3.8 - irled64-18x3tcsb irled56-18x3tcss with black finish IrLED64-18x3TCss with black finish 3.9 - iled64-18x5tcss 3.10 - iled64-18x5tcsb Optical: - 18x5W RGB LEDs - Beamwidth: 40 Connectors : - DMX IN and OUT via 3-pin XLR, - POWER IN/OUT via IEC sockets Power supply : 110/240 V 50/60 Hz Power consumption: 100 W Dimensions : 340 x 270 x 220 mm (PAR64 format)) Weight : 5 kg irled64-18x5tcss 25 with black finish 3.11 - iled64-18x5tcsb 25 Optical: - 12x3W RGB LEDs - Beamwidth: 25 Connectors : - DMX IN and OUT via 3-pin XLR, - POWER IN/OUT via IEC sockets Power supply: 110/240 V 50/60 Hz Power consumption: 40 W Dimensions : 340 x 270 x 220 mm (PAR64 format) Weight : 4 kg 3.12 - irled64-12x5tcss 25 IrLED64-12x3TCsb 25 with black finish Page 5

English irleds series - LED PAR projectors with infrared remote control 4 - Description 5 6 8 DMX OUT MODE UP DOWN POWER IN 240V/50Hz DMX IN 7 3 4 2 1 POWER OUT 240V/50Hz 1 Power input/output socket Allows you to connect the projector to an electrical outlet and to link several projectors together via a Male/Female IEC cord. Please make sure the voltage is in adequation with the product indications. Attention : Do NOT go over 700W on the same power source. 2 Fuse If need to replace the fuse, please make sure the new fuse has exactly the same characteristics as the original one. 3 DMX output 3-pin male XLR plug hardwired as follows : - Mass: 1 - Negative signal: 2 - Positive signal: 3 4 DMX input 3-pin female XLR plug hardwired as follows : - Mass: 1 - Negative signal: 2 - Positive signal: 3. 5 Display This intuitive display allows you to configure your projectors. Please refer to the next paragraphs for more details about the projectors cojnfigurations. 6 MODE button Allows you to access menus and select a function. 7 UP button Press UP to increase the adjustable values or browse the sub-menus. 8 DOWN button Press DOWN to decrease the adjustable values or browse the sub-menus. Page 6

irleds series - LED PAR projectors with infrared remote control English 5 - The internal menu Press the MODE button to acces the internal menu. To switch from a submenu to another, press the MODE button again. Simultaneously press MODE and DOWN if you want the display to shut off when the menu remains inactive. 5.1 - C.XX Menu: Choosing a fixed colour or sequence Press MODE until reaching C.XX. Press UP or DOWN to pick a colour. C.00 means the projector is in Black-out mode. Fixed colours and sequences are described below: C.00 Black-out C.01 Red C.02 Orange C.03 Yellow C.04 Green C.05 Cyan C.06 Blue C.07 Pink C.08 Magenta C.09 Cool white C.10 Warm white C.11 Colours sequencing (without crossfade) C.12 Blue to Green crossfade sequence C.13 Red to Orange crossfade sequence C.14 Crossfade sequence with every colour C.15 Warm white to cool white crossfade sequence 5.2 - J.XX Menu: Adjust the colour sequence speed (without crossfade): Press MODE until reaching J.XX. Press UP or DOWN to pick a value between 1 and 99. 1 is the slowest speed, 99 the fastest. 5.3 - F.XX Menu: Adjust the colour sequence speed (with crossfade) Press MODE until reaching F.XX. Press UP or DOWN to pick a value between 1 and 99. 1 is the slowest speed, 99 the fastest.. 5.4 - A.-- Menu: Switching to Auto mode Press MODE until reaching A.--. The projector will alternate between crossfade and step sequences. The sequencing speed described above will automatically be used. Page 7

English irleds series - LED PAR projectors with infrared remote control 5.5 - S.XX Menu: Activating the music-sensitive mode and configuring the mic sensitivity Press MODE until reaching S.00 and select a value with UP or DOWN. S.00 deactivates the music-sensitive mode. S.01 is a very low sensitivty, whereas S.31 is the max sensitivity. The colours are sequenced without crossfade when using the music-sensitive mode. 5.6 - S.L.A. Menu: Switching to slave mode Press MODE until reaching S.L.A. The projector will react to DMX signals coming from a similar projector. The Master unit can use the automatic, DMX or music-sensitive modes. 5.7 - XXX Menu: Switching to DMX mode Press MODE until reaching the value of the DMX address. Configure the DMX address with UP and DOWN. In the absence of any DMX signal, the display will flash. 5.8 - CH.X Menu: Choosing a DMX mode The irled PAR projectors feature several DMX modes to be fully compatible with different remote controls and projectors.use the UP or DOWN buttons to choose a mode. The 5 following modes are available: - 2-channel mode: Channel 1 = 10 preset colours, 5 macros and music-sensitive mode ; Channel 2 = Main dimmer. - 3-channel mode: Channel 1 = Red ; Channel 2 = Green ; Channel 3 = Blue - 4-channel mode: Channel 1 = Red ; Channel 2 = Green ; Channel 3 = Blue ; Channel 4 = Dimmer and Strobe - 5-channel mode: Channel 1 = Red ; Channel 2 = Green ; Channel 3 = Blue ; Channel 4 = Dimmer ; Channel 5 = Strobe - 6-channel mode: Channel 1 = Red ; Channel 2 = Green ; Channel 3 = Blue ; Channel 4 = Dimmer ; Channel 5 = Strobe or speed; Channel 6 = Fixed colours, colours sequencing and music-sensitive mode. Page 8

irleds series - LED PAR projectors with infrared remote control English 5 - The various DMX modes 6.1-2-channel mode CHANNEL 1 CHANNEL 2 DMX values Effect DMX values Effect 000-015 Off 016-030 Red 031-045 Orange 046-060 Yellow 061-075 Green 076-090 Cyan 091-105 Blue 106-120 Pink 121-135 Magenta 000-255 Dimmer from 0-100% 136-150 Cool white (6000 K) 151-165 Warm white (3200 K) 166-180 Colour macro 1 181-195 Colour macro 2 196-210 Colour macro 3 211-225 Colour macro 4 226-240 Colour macro 5 241-255 Music-sensitive colour macro 6.2-3-channel mode DMX values Effect CHANNEL 1 000-255 Red from 0-100% CHANNEL 2 000-255 Green from 0-100% CHANNEL 3 000-255 Blue from 0-100% 6.3-4-channel mode DMX values Effect CHANNEL 1 000-255 Red from 0-100% CHANNEL 2 000-255 Green from 0-100% CHANNEL 3 000-255 Blue from 0-100% 000-189 Main dimmer from 0-100% CHANNEL 4 190-250 Slow to fast strobe 251-255 Full power 6.4-5-channel mode Valeur DMX Effet CHANNEL 1 000-255 Red from 0-100% CHANNEL 2 000-255 Green from 0-100% CHANNEL 3 000-255 Blue from 0-100% CHANNEL 4 000-255 Main dimmer from 0-100% CHANNEL 5 000 No function 001-255 Slow to fast strobe Page 9

English irleds series - LED PAR projectors with infrared remote control 6.5-6-channel mode CHANNEL 6 CHAN.5 CHAN. 4 CHAN. 3 CHAN. 2 CHAN. 1 MODE DMX values Function 1 000-015 Black-out Blue (000-255) 0-100% Green (000-255) 0-100% Red (000-255) 0-100% 2 016-030 Red 3 031-045 Orange 4 046-050 Yellow 5 061-075 Green 6 076-090 Cyan 7 091-105 Blue 8 106-120 Pink 9 121-135 Magenta 10 136-150 Cool white (6000 K) Strobe (016-255) From slow to fast - 0,1Hz to 20Hz Main dimmer (000-255) from 0-100% No function No function No function 11 151-165 Warm white (3000 K) 12 166-180 Macro 1 13 181-195 Macro 2 14 196-210 Macro 3 15 211-225 Macro 4 Speed (000-255) From slow to fast 16 226-240 Macro 5 17 241-255 Music-sensitive sequencing Mic sensitivity Page 10

irleds series - LED PAR projectors with infrared remote control English 7 - Infrared remote control The infrared remote control supplied with the projectors allows you to remotely access all the functions of the projectors. The infrared sensor is located on the front of the projector. Note : The remote control can also be used when the projector is in DMX mode. 1 - Black out button: Turns the projectors ON or OFF. 2 - A (AUTO RUN) button: Activates the automatic mode. Automatic colour changes. 3 - PROG (SELECT PROG) button: Launches built-in programs. Select a program among the 10 fixed colours selections (red, green, cyan...), Color Jumping (fast colour sequencing) and Color Dream (slower colour sequencing) by pressing the + and - buttons. Note : Fixed colours can also be chosen with the 0 to 9 buttons. The sequencing is as follows: 0 = black-out ; 1 = Red ; 2 = Green ; 3 = Blue ; 4 = Orange ; 5 = Yellow; 6 = Magenta, 7 = Cyan, 8 = Cool white and 9 = Warm white. 4 - F button (FLASH): Activates or deactivates the Flash mode. Increase or decrease the flash speed with the + and - buttons of the remote control. 5 - SP button: Allows you to configure the Color Jumping and Color Dream programs speed. Increase or decrease the speed with the + and - buttons of the remote control. 6 - D button (DMX MODE): Activates the DMX mode of the projectors. 7 - DMX mode selection There are 5 different DMX modes. You will need to select a DMX mode before controlling your projector in DMX mode ; Press the D button (DMX MODE) and use the + and - buttons to switch from one mode to another : - When the LEDs are red, the projector is currently using the 2-channel mode. - When the LEDs are green, the projector is currently using the 3-channel mode. - When the LEDs are blue, the projector is currently using the 4-channel mode. - When the LEDs are red and green, the projector is currently using the 5-channel mode. - When the LEDs are red and blue, the projector is currently using the 6-channel mode. 8 - SA button: Activates the music-sensitive mode. 9 - SL button (SLAVE): Activates the slave mode. 10 - SET ADDR buttons and 0, 1, 2, 3, 4, 5, 6, 7, 8 and 9: Allows you to configure your projectors DMX address. For instance, if you want to configure the address 245 : - Press S, all the LEDs are flashing to indicate the beginning of the process. - Press 2, the green LEDs of your projectors lit up to indicate the hundreds digit has been saved. - Press 4, the blue LEDs of your projector lit up to indicate the tenths digit has been saved. - Then press 5. All the LEDs will flash to confirm you the address has been saved properly. To configure the address 002: - Press S, all the LEDs are flashing to indicate the process beginning. - Press 0, the green LEDs of your projectors lit up to indicate the hundreds digit has been saved. - Press 0, the blue LEDs of your projector lit up to indicate the tenths digit has been saved. - Then press 2. All the LEDs will flash to confirm you the address has been saved properly. 11 - R, G and B buttons : Adjusts colours brightness, R for red, G for green and B for blue. Increase or decrease their brightness with the + and - buttons. Page 11

Because CONTEST takes the utmost care in its products to make sure you only get the best possible quality, our products are subjects to modifications without prior notice. That is why technical specifications and the products physical configuration might differ from the illustrations. Make sure you get the latest news and updates about the CONTEST products on www.contest-lighting.com CONTEST is a trademark of HITMUSIC S.A. - Zone Cahors sud - 46230 FONTANES - FRANCE