BCA 9R. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

Similar documents
BCA 9S. ELECTRICAL CHARACTERISTICS Voltage 230 Vac ±10% monophase standard 105 / 115 / 125 / 220 / 240 Vac ±10% monophase on request

TCA 6 S. 115Vac. Class I with applied parts type B Continuous functioning with intermittent loading. nominal voltage 230Vac.

ziehm imaging ... dedicated to clinical innovation Ziehm Vista. TECHNICAL SPECIFICATIONS Most Versatile C-arm.

Intra-oral X-ray unit with high frequency DC generator. Product Data

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life.

Comed Medical Systems Co., Ltd. Office 707, Woolim Lion s Valley I, 311-3, Sangdaewon-dong, Seongnam-si, Gyeonggi-do, Korea Tel:

X-ray Tube Housing Assembly H1076X H1076Y Print No.HA Release Date:

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

PLV-Z2 ROLL THE FILM FOR THE FUTURE!

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

High Frequency X-Ray Technology. Wide Screen Control with Touch-Technology

Practix. Mobile Radiography. All a Bucky station needs plus mobility. Practix 400

Chapter Medical Table of Contents

WARNING: The information that is printed within this manual is vital for the correct use of the equipment; please read it carefully before use.

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Advantech Proudly Presents Professional Monitor Series

FLAT DISPLAY TECHNOLOGY

SPECIFICATION NO Model 207 Automatic GTAW Welding System

55-inch Class FULL HD LCD Display TH-55SF1HW

Simple all-in-one design style with front stereo speakers and natural ventilation system

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1

GUARD BAGAŽO TIKRINIMO VARTAI

17" 0.51 x 0.51mm Max. resolution. 500TVL / (SVGA) Contrast ratio. 500:1 (TYP) Brightness 500:1(TYP.) 420cd/m 2 (TYP.)

HITACHI. Instruction Manual VL-21A

Pro Type Series. Eco Type Series

: V [p-p] (high impedance) AUDIO IN Stereo mini Jack (M3) x 1 (Shared with DVI-D IN) 0.5 V [rms] D-sub 9-pin x 1 / x 1, RS-232C Compatible

Gateway 50-inch Plasma TV Specifications

XC-77 (EIA), XC-77CE (CCIR)

QuickSpecs. Models RB146AA#ABA Standard Configuration RB146AT#ABA Promotional Part Number (SmartBuy) HP L5006tm 15-inch LCD Touchscreen Monitor

QuickSpecs. HP VH27 27-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. Exit

INSTALLATION MANUAL. ST-CVTMD420-WPIR-W Covert Motion Detection Color Camera. v1.3 8/11/11 1

Department of Radiology

Automatic Camera Tracking System

CM-S38901SV TVL IR Long Range camera

Gateway 46-inch Plasma TV Specifications

Coronis Uniti (MDMC-12133) 12MP diagnostic display system for PACS and breast imaging

1928L Multifunction 19-inch Desktop Touchmonitor

CM-S23349SV. Vari-Focal IR Bullet Camera

TH-55LF80U. 55-inch Class FULL HD LCD Display. Product specification (design and specification subject to change without notice) DISPLAY PANEL

SPECIFICATION NO NOTE

TH-42LF80U. 42-inch Class FULL HD LCD Display. Product specification (design and specification subject to change without notice) DISPLAY PANEL

UArm. Series. Analog or Digital U-Arm System

Gamma instabus. Technical product information

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

MAP110 AC-DC Series Data Sheet

. ImagePRO. ImagePRO-SDI. ImagePRO-HD. ImagePRO TM. Multi-format image processor line

QuickSpecs. HP V19b 18.5-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK. 1. Power connector 3. Security lock slot 2.

QuickSpecs. HP N inch Monitor. Technical Specifications

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

Video Series. HCS-4311M Professional Mixed Matrix for Conference 8.2. HCS-3313C High Quality Speed Dome Camera (ceiling) 8.5

Outdoor IR Audio Camera

Dental Line. High frequency intraoral x-ray unit. radiology ahead

15 Inch CGA EGA VGA to XGA LCD Wide Viewing Angle Panel ID# 833

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

LCD Display Wall Narrow Bezel Series

G ARD SECURITY SYSTEM Product Listing 2007

G-106 GWarp Processor. G-106 is multiple purpose video processor with warp, de-warp, video wall control, format conversion,

G-106Ex Single channel edge blending Processor. G-106Ex is multiple purpose video processor with warp, de-warp, video wall control, format

LMD-1541W. 15-inch high grade LCD monitor. Overview

QuickSpecs. Models RB146AA#ABA Standard Configuration RB146AT#ABA Promotional Part Number (SmartBuy)

CATALOG NUMBER: HK-MX-VGA-X-Y Product Name

HP Engage One 10.1 Display (Black) HP Engage One 10.1 Display (White)

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

LCD Display Wall Narrow Bezel Series

HK-DID-MXA-VGA-X-Y. Product Name. Describe. Application. Characteristic. Product Model. Screen Matrix Switcher

WVR500 Waveform/Vector Monitor

Request for Proposals

27" 10-point multi-touch interactive display

SX-17P Surveillance LCD Display

IFM65UG OPS-COMPLIANT 16/7 400 NITS ULTRA HD INTERACTIVE FLAT PANEL DISPLAY

Intelligent Security and Fire Ltd

Digital SWIR Scanning Laser Doppler Vibrometer

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor

ScopeMeter 190 Series Specifications

QuickSpecs. HP V inch Monitor. Overview

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

TFT LCD MONITOR USER MANUAL. L80AP and L101AP

PT-LW330 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/9.

BeneHeart R3. Electrocardiograph

In-process inspection: Inspector technology and concept

VIDEOWALL NARROW BEZEL. 40" and 46" I N F I N I T E S O L U T I O N S F O R V I S U A L C O M M U N I C AT I O N

COLOR TFT LCD MONITOR. User Manual

Need a bright idea? How about using FURUNO marine grade monitors in your helm!

PMCL300 Series TFT LCD Monitor 17-INCH, 19-INCH, OR 19-INCH WIDE, WITH MULTIMODE FUNCTIONALITY

ADN-8126 JJTRON Display System

1215L 12 LCD Desktop Touchmonitor

Global Trade Medical Supplies


LD OEM/LD PDS/LD PeCo

43 Professional Monitors

QuickSpecs. HP N220h 21.5-inch Monitor. Overview. 1. Menu/OK 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. Exit/Back

1215L 12" LCD Desktop Touchmonitor

1215L 12" LCD Desktop Touchmonitor

YSC -HD-AK1 HDMI / HD-SDI

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

26 Inch CGA/EGA/VGA/DVI to WXGA/1080p LCD - ID#703

Transcription:

ELECTRICAL CHARACTERISTICS RADIOLOGICAL DATA MONOBLOC Voltage 230 Vac ±10% monophase standard 105 / 115 / 125 / 220 / 240 Vac ±10% monophase on request Frequency 50 Hz standard 60 Hz on request Absorbed current on Stationary 4.5 A @ 230 Vac and 7.5 A @ 115 Vac in fluoro mode Anode Unit 20 A @ 230 Vac and 28 A @ 115 Vac in radiography mode Line compensation Automatic Line resistance < 0.4Ω (supply at 230V) < 0.2Ω (supply at 115V) Standard mains plug 16 A (for supply at 230 Vac) Generator power in DC current 5 kw (100 kv, 50 ma, 64 ms) High frequency inverter 40 khz Max. Ripple <2% @ 100 kv Max high voltage 120 kvp (radiography and fluoroscopy) Max current in continuous fluoroscopy 8 ma Max current in fluoroscopy Boost 12 ma Max current in radiography 25 ma @ 230 V 18 ma @ 115 V Max mas in radiology 125 mas @ 230 V 90 mas @ 115 V Exposure Time in radiography 0.04 5 sec Anode Rotating Anode inclination 10 Focal Spot size according to IEC 336 0.3 mm small focus 0.6 mm large focus Nominal anodic power 5 kw small focus 17 kw large focus Max anode cooling speed 33 khu/min (25 kj/min) Monobloc thermal capacity 600 kj (670 khu) Max continuous thermal dissipation 75 W, 102 HU/sec, 6120 HU/min of the monobloc Max. Fluoroscopy time HU safety after 28' of fluoroscopy @ 120 kv, 5 ma (600 W) Max fluoroscopy time @75W 75 kv - 1mA - Continuous fluoro (no limits) Max fluoroscopy time @280W 80 kv - 3.5 ma - 54 Minutes Max fluoroscopy time @400W 100 kv - 4 ma - 38 Minutes Max fluoroscopy time @525W 70 kv - 7.5 ma - 31 Minutes Max fluoroscopy time @550W 110 kv - 5 ma - 30 Minutes Max fluoroscopy time @600W 120 kv - 5 ma - 28 Minutes Total filtration > 2.7 mm Al

COLLIMATOR Type Standard: Iris + parallel shutters Iris Orientable shutters Control by console with adjustable continuous opening until the max. allowed in function of the I.I. field selected. Iris automatic limitation on the I.I. field selected Control by console for the opening/closing and clockwise/ anti-clockwise rotation IMAGE INTENSIFIER TUBE - 9/6/4 Field Number 3 Input nominal diameter 230 mm Resolution (central) 48 / 56 / 64 lp/cm Conversion factor 240 / 120 / 60 (cd. m -2 / mr. s -1 ) Contrast Ratio 23:1 / 25:1 / 30:1 DQE @ 59.5 kv 65% MTF 60% / 65% / 70% @ 10lp/cm 25% / 30% / 40% @ 20lp/cm Integral Distortion 4% / 2% / 1% All metal Technology Yes Input screen Hi-Res Yes Antiscatter fixed grid Ratio 8:1, 36 shutters/cm, focus 80 cm CCD CAMERA 0.5K x 0.5K Matrix 752 x 582 pixels Technology CCD sensor (470.000 pixels) Video Standard CCIR 625/50Hz interlaced with 752 x 582 pixels Video Bandwidth 20 MHz ±3dB Aspect ratio 4:3 Interlaced scanning Signal - Noise Ratio 65 db Automatic video level compensation Dynamic contrast shading

Image format DIGITAL IMAGE SYSTEM WITH 0.5K x 0.5K CCD CAMERA LIH 1+330 1+2700 DIP 3000A 768 x 576 x 12bits 50 Hz 256 grey level 768 x 576 x 12bits 50 Hz 256 grey level 768 x 576 x 12bits 50 Hz 256 grey level 576 x 576 x 12 bits Image format working memory N.A. N.A. N.A. 576 x 576 x 12 bits Number of images 1 RAM 1 + 330 Non volatile 1 + 2700 Non volatile 1 + 192 buffer RAM Number of images on Hard Disk NO NO NO About 40.000 Programmable frame rate acquisition NO NO NO 1, 3, 6 fps Number of monitors 1 (17 ) 2 (19 ) 2 (19 ) 2 (19 ) Flicker Free Recursive filter, Noise Reduction, OFF 0, 2, 4, 8, 16 0, 2, 4, 8, 16 0, 2, 4, 8, 16 0, 2, 4, 8, 16 Smart filter, motion detector NO NO NO (algorithms) Editing data patient NO Digital Rotation of the image without X-ray emission Vertical / Horizontal Image inversion in combination with rotation in combination with rotation in combination with rotation Left / Right image inversion NO NO NO Edge enhancement Smooth, Normal Sharp Smooth, Normal Sharp Smooth, Normal Sharp Smooth, Normal Sharp in real time Grey scale inversion (negative / positive) NO Cine loop review NO NO NO Real Time Subtraction (DSA) NO NO NO Max opac. NO NO NO Road-mapping, capability for catheter placement NO NO NO Shifting Pixel NO NO NO Land marking NO NO NO Overview NO NO NO, 4 / 16 images Zoom NO NO NO by 2 Virtual Shutter NO NO NO Contrast Enhancement NO NO NO with Logaritmic Exponential curve Digital adjustment for contrast / brightness NO NO NO Text editing NO NO NO Overlay Note NO NO NO Patients Directory NO NO NO Infrared Remote Control NO NO NO Optional Start-Stop DVD Recorder synchronization NO NO NO

MONITORS COLOR LCD DISPLAY VERSION 17" 19" Panel / type 17 TFT active matrix LCD, anti veiling glare, medical 19 TFT LCD anti-glare, medical HARDWARE REQUIREMENTS Brightness and contrast controls Dedicated knobs Front pushbuttons ELECTRICAL CHARACTERISTICS Standard power supply Current absorbed Power absorbed 18Vdc ±10% 3 A 55 W 110 to 240 Vac 60/50Hz --- 42 W DISPLAY CHARACTERICS Visibility angle Contrast Resolution Pixel pitch Active Display area Gray scale Max luminance Aspect ratio Response time Video input 180 1000:1 1280 x 1024 0.264 x 0.264 mm --- 768 levels 350 Cd/m 2 4:3 25 ms 2 BNC connectors 2 BNC connectors 75 Ohm 178 800:1 1280 x 1024 0.294 x 0.294 mm 376 mm (H) x 301 mm (V) 256 x 3 = 768 levels / 16.7 Milion colours 250 Cd/m 2 4:3 15 ms 2 x BNC / 1 x D-Sub (VGA) / 1 x D-Sub (DVI-D) ENVIROMENT AND RELIABILITY Operative from 0 to +40 C Humidity: 10% to 80% (non condensing) from 0 to +40 C Humidity: 20% to 80% (non condensing) Temperature and storage from -20 to +60 C Humidity: 5% to 85% (non condensing) from -30 to +70 C Humidity: 10% to 80% (non condensing)

FUNCTIONALITY DESCRIPTION DATA User s interface Selectable languages I.I. field selection Thermal units Fluoroscopy control On Stand Monitor position Safeties Membrane keyboard with alphanumeric touch-screen 5.7 LCD display for all the operative parameters and messages of eventual faulty conditions. Microprocessor management. User interface control could be rotate of 60 Italian, English, French, German, Spanish (selection by set-up) Electronic zoom selection according to the number of I.I. fields with automatic limitation of the radiated field by the iris collimator. Check and visualization in real time of thermal units on the display according to the applied load. From 100% to 5% XR enabled. When there are 5 minutes of fluoroscopy (for the kv and ma values in use in that moment) to reach the 5% of the HUT, a particular audio-visible signal is activated. If more than 5 minutes are necessary to finish the exam, the fluoroscopy data have to be lowered. After reaching the 5% of the available HUT, the x-ray emission is stopped (*). In order to go on with the fluoroscopy, it is necessary to wait that the HUT have reached at least the 10%. (*) In particular conditions it is possible to exclude this block and go on with the exam, under the direct responsibility of the qualified personnel or the doctor that uses the unit. In radiography it is not possible to control the x-ray emission any more when the 5% of the available HUT is reached. Multi-functioning foot switch: Pedal for continuous, pulsed and single shot (boost) fluoroscopy (functions selection by 3 different foot switches). Storage image on memory by foot switch without interrupting fluoroscopy General magneto-thermic switch Key safety switch Emergency pushbutton Printer for Dose Area meter (optional) Directly on the stand with 1 monitor LCD orientable 17 NL series or: Monitor trolley with five wheels, two of them with stationary brake Lamp for x-ray emission warning Cable winding support Digital system with CCD 0.5K x 0.5 K Two monitors LCD 19 Alphanumeric keyboard Thermal Printer Sony or equivalent Medical Image Capture Device: MediCap USB150 Filament current Monobloc temperature Overload kv min/max. or fault H.V. Stored data check

OPERATIONAL MODES WITH 0.5K x 0.5K CCD CAMERA OPERATIONAL MODES MODE CHARACTERISTIC PERFORMANCES Continuous Dose control (kv - ma) Automatic or manual fluoroscopy Small Focus 0.3 mm (IAE Tube) kv variation range 40-120 kv ma variation range 0.5-8 ma kv - ma correlation Standard: 40 kv / 0.5 ma, 80 kv / 7.6 ma, 120 kv / 8mA Safety timer Audible alarm resettable after 5 x-ray x-ray stop after 10 of continuous radiations according to IEC 60601-2-7 29.1.104 Last image hold (LIH) Pulsed fluoroscopy Range of exposure rate variation (Selectable by console) From 2 image/sec to 1 image every 5 sec (2 image / 1s; 1image / 1s; 1 image / 2s; 1 image / 3s; 1 image / 5s) XR flash time Minimum time for better image Other characteristics as per the continuous fluoroscopy One-shot Digital ma variation range 1-12 ma Radiography XR flash time < 1 sec Acquisition obtained by integrating 16 following readings Automatic storage of the image on RAM or nonvolatile memory, according to the memory type Other characteristics as for the continuous fluoroscopy ma 1/2 fluoroscopy ma variation range 0.25-4 ma kv - ma correlation 40 kv / 0.25 ma, 80 kv / 3.8 ma, 120 kv / 4mA Other characteristics as per the continuous fluoroscopy Anatomic APR APR 1 ma Low Anatomic fine parts or paediatric use selection, from 0.7 ma to 6.6 ma 40 kv / 0.7 ma in fluoroscopy 80 kv / 6.4 ma 120 kv / 6.6 ma APR 2 ma Low Lungs from 0.5 ma to 7 ma 40 kv / 0.5 ma 80 kv / 7 ma 120 kv / 5.5 ma The curves cannot be modified by the operator Radiography Working technique 2 points with kv and mas setting Large Focus 0.6 mm (IAE Tube) kv variation range 40-120 kv ma variation range @ 230 Vac 25 ma fixed from 40 kv to 100 kv; 20 ma at 120 kv @ 115 Vac 18 ma fixed from 40 kv to 100 kv; 15 ma at 120 kv APR anatomic selection in radiography mas variation range @ 230 Vac 1-125 mas from 40 to 100kV 1-100 mas from 101 to 120kV in 42 steps, R 20 curve 0.04-5 sec max @ 115 Vac 1-90 mas from 40 to 100kV 1-71 mas from 101 to 120kV Times range Use coefficient (duty cycle) Calculated as per the anode dissipation Description Norm Paediatric Adult APR 1 Head 77 kv 56 mas 74 kv 45 mas 80 kv 71 mas APR 2 Lungs 110 kv 11 mas 107 kv 9m As 110 kv 14 mas APR 3 Pelvis 85 kv 22 mas 82 kv 28 mas 88 kv 18 mas Possibility to change and store with every APR: kv and mas

ENVIRONMENTAL CONDITIONS Environmental condition in Normal Use Environmental condition in Transport and Warehouse Humidity: Pressure: Humidity: Pressure: from +10 to +40 Celsius from 30% to 75% non condensing from 700 to 1060 hpa from -25 to +70 Celsius from 10% to 90% not condensing from 500 to 1060 hpa WEIGHT AND DIMENSION Description Stand Trolley, mod. "Low" Trolley, mod. "Standard" Trolley, mod. "High" Weight About 360 kg About 67 kg About 97 kg About150kg (1) Width 859 mm 830 mm 870 mm 872 mm (2) Depth in transport position 2000 mm 855 mm 855 mm 577 mm (3) Height in transport position 1780 m 1605 mm 1605 mm 1603 mm Weights and dimensions can vary with different accessories MECHANICAL CHARACTERISTICS Vertical motion Horizontal motion 500 mm motorized in 60 sec 210 mm Panning motion ± 270 Orbital rotation 123 (+90-33 ) Pivotal rotation ± 12.5 Free Space Depth S.I.D. Focus Skin distance Movement Stand Wheels diameter Trolley Wheels diameter Protection against cables squashing 770 mm 690 mm 970 mm 200 mm Manual. Steering rear wheels with manual control by the operator, swiveling front wheel. Stationary brake by hand Rear: Double wheels 125 x 40 mm Front: Double wheels 80 x 30 mm Base Trolley 5 x 80 x 35 mm with brake High configuration Trolley 4 x 125 x 30 mm with brake Semi-rigid rubber core-hitch on all the wheels of the stand.

TECHNICAL DATA STAND Dimension in mm (D) - 33 (D) 90 (C) ±270 (H) (I) (F) 770 [30,31] (G) 690 [27,17] 848 [33,39] (3) 1800 [70,87] (2) 2000 [78,74] (1) 859 [33,82] (E) ±12,5 520 [20,47] 675 [26,57] 954 [37,56] (L) (M) (N) 557 [21.93] 1835 [72,24] (B) 210 [8,27] FIXED ANODE ROTATING ANODE (H) 988 mm 970 mm (I) 218 mm 200 mm (L) 172 mm 152 mm (M) 339 mm 357 mm

TECHNICAL DATA TROLLEY MOD. "STANDARD" Dimension in mm 439 [17,28] (1) 869 [34,21] 1021 [40,20] 694 [27,32] 1378 [54,25] (3) 1606 [63,23] 352 [13,86] 431 [16,97] (2) 855 [33,66]

TECHNICAL DATA TROLLEY MOD. "HIGH" 441 545 859 1061 1131 1061 1372 65 352 1548 352 600 Note Technical Specs can be subject to changes, in order to grant the highest quality levels, and so they can vary without ntice obligation ESSE 3 Via Garibaldi 30 14022 Castelnuovo D.B. (AT) tel +39 011 99 27 706 fax +39 011 99 27 506 e-mail esse3@tuttopmi.it web : www.4ci.com