metrotile Roofing for Conservatories The No Drama Roof Including new-build conservatories and solid roof conversions 07/4470

Similar documents
Packaged Designs, Products & Solutions

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Cellular Signal Booster

3M - A Global, Diversified Technology Company

Changing Skylines THE FUTURE PROOF ROOF LIGHTWEIGHT HIGH QUALITY LONG LASTING LOW MAINTENANCE WEATHER TESTED ECOLOGICAL LOW NOISE ECONOMIC STRONG

In-Line or 75 Ohm In-Line

.Power Distribution Center. PD-1. Instruction Manual

Guide. Installation. AG Pro 75 Smart Technology In-Building Wireless 800/1900 MHz Adjustable Gain Signal Booster. Wilson

Communication Markets Division 3M Scotchlok Connectors and Tools. Proven. Solutions for. Today s Applications

ELECTRICAL SAFETY INSPECTION REPORT

Type Approval Certificate

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

OMNIBLAST-E MODULAR LED FLOODLIGHTING SOLUTION FLEXIBILITY THROUGH MODULAR DESIGN SUPERIOR OPTICAL EFFICIENCY ADVANCED CONTROL OPTIONS

3M - A Global, Diversified Technology Company

Built tough for long-term connections

Built tough for long-term connections

HOG 86. The incremental HeavyDuty encoder for highest demands

User Manual MagniLink Mira

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

Changing Skylines LIGHTWEIGHT HIGH QUALITY LONG LASTING LOW MAINTENANCE WEATHER TESTED ECOLOGICAL LOW NOISE ECONOMIC STRONG.

RACK MOUNT KIT RMK-2 Quick Start Guide

Australian and New Zealand Energy Performance and Marking Requirements for External Power Supplies

Photovoltaic Module Installation Manual (IEC)

Wilson. Adjustable Gain Signal Boosters AG Pro 75, AG Pro 70, AG Pro Installer, AG SOHO 65, AG SOHO 60

All-Glass Sliding-System SF20

All-Glass Sliding-System SF20

SmartCrystal Cinema Neo

3 Cleaning. 4 Technical data

Get Connected. Download the free Pure Connect app to immerse yourself in music.

Modular operating rooms Sundsvall Regional Hospital

Valve Amplification Company

Table of Contents. Read This First.2. Introduction by Jim Fosgate...3. Unpacking..4. Tubes and Tube shield Installation 5. Product Placement...

Forced Convection Laboratory Ovens

ASTM E a Fire Tests Of Building Construction and Materials *Modified SMALL-SCALE TEST OF FIREBLOCKING MATERIALS

Zehnder ZLTCA Low surface temperature radiators. Heating Cooling Fresh Air Clean Air

3M Super 23 Electrical Tape

Photovoltaic Module Installation Manual (IEC)

FUNCTION IN FIRE EXPERT JUDGEMENT REPORT WITH CLASSIFICATION FIRES-JR NURE

X-ray Tube Housing Assembly H1076X H1076Y Print No.HA Release Date:

Official Journal of the European Union L 82/3 DECISIONS COMMISSION

Cellular Signal Booster

Figure 1. High Efficiency T8 LED Tube. Figure 3. Full View of Light High Efficiency T8 LED Tube

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Projectors EFFORTS FOR PROJECTOR QUALITY

1PXL Board CW/WW/DW. Power Consumption 8W max. 8W max. 15W max.

WHAT IS VECTOTHOR?; VECTOTHOR INSECT CONTROL LIGHT TRAPS USE CUTTING EDGE SCIENCE TO FLY AHEAD OF THE COMPETITION

RemotePoint. Navigator. User s Manual VP4150

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Guide. Installation. Signal Booster. Wilson. DB Pro Adjustable Gain 800/1900 MHz In-Building Wireless Smart Technology

SPEED LIMIT YOUR SPEED SPEED LIMIT YOUR SPEED SPEED LIMIT YOUR SPEED SCHOOL YOUR SPEED. Information Display Company WHEN CHILDREN ARE PRESENT

User Manual. Model 979T and 979R Digital Audio Converters

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Instrukcja montażu. FLEX LED Neon Instalacja

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

Thank you for purchasing a qualiton APR204 preamplifier!

Atlas SCR. User Guide. Thyristor and Triac Analyser Model SCR100

Philips CoralCare FAQ

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 120,000 BTUH S9V2D120D5-SUB-1-EN. March 2016 S9V2D120D5PSAA TAG:

ES-3305P / ES-3308P / ES-3316P. Quick Installation Guide / v1.0

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Technical Data Sheet. Scotchlite Reflective Material Series 6100 High Gloss Trim Series 6200 High Gloss Film. Retroreflective Performance.

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.

TBC & Matrix Switcher TBC-5000 Instruction Manual

Scotchlok Connectors and Tools

Technical requirements & conditions for hirers

Owner Handbook. Jupiter Blackhole. LED UV Flood

*** no equipment put on roofs or buildings. Dish must be put in ground 3 feet from building to allow for mowing. ***

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Cellular Signal Booster

LUXFLEX PREMIUM THIN & FLEXIBLE BACKLIGHTING. Indoor/Outdoor Series

Product Data Sheet 8506 VW-691

User Manual CVA3. HDMI Audio Decoder. All Rights Reserved. Version: CVA3_2016V1.0

Catalogue. Rollers for belt conveyors

TRF STEP-DOWN TRANSFORMER USER MANUAL

SmartCrystal Cinema Neo

INSTALLATION MANUAL. 4. Chase all cables into the wall at the bottom of the TV to reduce chances of water reaching the TV.

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Warnings and Precautions

Cyclo Series. user manual. MartinArchitectural

Good Reasons to believe in COLORBOND steel for Roof and Wall Cladding Application

Solderless RF Connectors

U S E R M A N U A L SMIIRL 2017

LED MODULES READYLINE DL

Magic Patch Patch Leads & Accessories

CONCRETE CONSOLIDATION

The Zehnder LST brings a safe, attractive heating solution to applications where hot radiant surfaces are undesirable.

Repeater & Power Adaptor VP-633 HD/SD SDI Repeater VP-634 Quick Start Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

AWT150C/AWT150CS/ AWT151C CCD Camera

The AMS 5ICT LS is a full bandwidth 200-Watt high sensitivity loudspeaker that utilises our all-new proprietary 5" ICT (Inductive Coupling

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

TracVision R6DX Installation Guide

CATEGORY 6 CABLING SOLUTIONS

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Flexible Cord. Inside this section

Connectorized and Pre-Loaded HIGH PERFORMANCE CABLE CARRIER SYSTEMS

T850 Day & Night Security Camera

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

American Power Design, Inc.

Transcription:

metrotile The No Drama Roof www.metrotile.co.uk 01249 658514 07/4470 Roofing for Conservatories Including new-build conservatories and solid roof conversions

Roofing for Conservatories: The Metrotile Benefits Insulation can be significantly improved, reducing home energy bills Traditional conservatory roof benefits without the strain on structure and foundations Highly secure against vandalism and extreme weather Highest external fire resistance rating Velux windows and ventilation systems easily incorporated Low weight ensures rapid installation 40 Year Weatherproof Guarantee Highly experienced customer support Eu Ejndv Stunning aesthetics

FORTY YEAR WEATHERPROOF GUARANTEE THE FUTURE PROOF ROOF For technical information: metrotile KNOWLEDGEBASE knowledgebase.metrotile.co.uk 40 From small conservatory roofs to larger spaces on heritage homes, many people are finding that a Metrotile roof is key to turning what is traditionally a summertime space into an area that can be enjoyed all year round and that s before you take Metrotile s 40-year weather-proof guarantee into account! Leading conservatory fabricators across the UK continually use Metrotile as a roofing material supplier while contractors are using Metrotile to convert existing conservatory roofs in a drive to keep home energy costs down. So, whether your project is a refurbishment or to be built from the ground up, Metrotile has it covered. Lightweight steel roofing As a Metrotile roof weighs up to one seventh of traditional roofing materials, a upvc frame conservatory is now able to have a Metrotile roof installed upon it. From Rafters and VPU for insulation, to Velux windows for natural light and even a plethora of lighting options installed into the conservatory ceiling a Metrotile conservatory roof makes this all possible and means you don t lose the space of your conservatory to the cold, damp winter months. With a Metrotile conservatory roof conversion, keeping the sliding doors sealed shut through the winter is a thing of the past. Improved insulation The improvement to insulation should not be overlooked. It s no secret that UK energy prices have been increasing annually, squeezing UK residents out of more money in exchange for less energy. By improving the insulation of your conservatory, you can keep your home warm at less expense while ensuring less of the money spent on energy is wasted. Low pitch roofing When constructing your new conservatory, it s important to give some clearance between the conservatory roof and the upstairs windows of your home. Metrotile low pitch roof tiles can be installed as low as 10 which accounts for any windows above your home, giving leeway while matching the rest of your home exterior. To find out more about a conservatory roof replacement, get in touch with Metrotile by calling us on 01249 658 514, emailing via sales@metrotile.co.uk or completing the contact form at www.metortile.co.uk.

Safety regulations are focused on the importance of saving life, rather than saving property. Tests are based on how long each element of a structure will stand up to fire but have little to do with what happens once the fire has actually become established. In our area of specialism, fire safety tests are intended to show how well a roof can resist a fire from a source outside the building itself, firstly regarding the penetration of the roof, and secondly spreading across its surface. BS 476-3: 2004 - Fire test on building materials and structures - Part 3: Classification and methods of test for external fire exposure to roofs. Rating achieved: EXT.S.AA* *EXT means it is for external roofs. The S stands for sloped the alternative you will come across is an F for flat.the two As are the ratings for resistance to fire penetration, first, and flame spread, second. For fire penetration, the A rating means the tested product has not been penetrated within one hour of testing under flame. The lowest rating, rating D, means the product was penetrated almost straight away, which the B and C ratings are given to those which fall either side of the 30 minute mark. For fire spread, rating A means that there was no spread of flame during testing for 60 minutes. B means a spread of 21 inches or less, C means more than 21 inches and D means the product carries on burning five minutes after the flame is removed, or that there is a 15 inch spread straight away. There is also an additional rating, which is the addition of a letter X (for example EXT.S.BCX), which denotes the presence of any flaming droplets from the edge of the product, mechanical failure or any development of holes under testing. The other issue to consider is distance from boundaries with regards to building regulations. Anything with Broof (t4) or an AA, AB or AC rating can be safely constructed six metres or less from a property boundary. NB: As to European standards, there is ENV 1187 which is the basis for standards which are intended to eventually replace BS 476-3: 2004. As yet, ENV 1187 has yet to be granted full European Standard status but when an amended version of it is sent through, it is likely to take over our national standards. At Metrotile, our products are tested against these standards as well. We like to excel where we can. The classification is known as BS EN 13501-5 and runs from B at the top end to F at the bottom, followed by roof (t4), with t4 showing that a two-stage test method has been used, incorporating burning brands, wind and supplementary radiant heat. UK or EU the measurements are the same. So when the standards are met to the highest classification, you can be sure that a roof will not be penetrated by external fire in an hour, it will carry on burning for less than five minutes and that flame spread will be minimal Eu Ed Fire Rating Explained

07/4470

BBA certifications Metrotile profiles are covered by the BBA. This certificate is professionally recognised in the UK and it s granted to designers and installers who use professional constructional products and systems. Our current BBA certificates can be downloaded from the Metrotile Knowledge Base and also directly from the BBA website. LABC Registration Metrotile has become LABC registered for our roofing profiles. This means we offer a consistent product that is tested by the Local Authority Building Control and exceeds the standards set, enabling us to provide a better service to all specifiers, installers, developers and building control surveyors. The LABC represents all local authority and compliance in England, Wales and Scotland. A company registered with the scheme proves that they meet industry-led standards. Not only this, but a registered product is more likely to be accepted by all local authorities, can improve the speed and ease of the building control process and guarantee easier warranty approval. The LABC carried out assessments on Metrotile s profiles, testing its wind loading, moisture penetration, corrosion resistance and surface spread of flame. They also examine starter courses, abutment tiles, ridge tiles, barge closers, tile vents, soil and vent outlets and extractor fan outlets for a comprehensive outlook on the product. Metrotile s accreditation LABC found Metrotile s products to be internationally compliant for every test, citing that the tiles resist high rain and hail exposure and also resist corrosion due to salt exposure in marine locations. The system was found to offer protection from the most severe UV exposure and all these elements are backed by a 40 year weatherproof guarantee. The LABC confirmed that Metrotile s products are built to last, and can offer building protection from wind, fire and the weather elements. In addition to our BBA certificates and LABC registration, Metrotile s products have also achieved the CE mark, while their manufacturing plant has achieved both ISO9001 and ISO14001. Eu Ed Certifications and Testing

www.metrotile.co.uk Tel: 01249 658514 email: sales@metrotile.co.uk Twitter: @metrotileuk Metrotile UK Ltd Unit 3, Sheldon Business Park Sheldon Corner, Chippenham Wiltshire, SN14 0RQ Registration No. 2680324 Registered in England & Wales