Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

Similar documents
9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

AS09..S 3-pole Contactors - Spring Terminals

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Analog Panel Meters Preference Program Basic Series Vario Series

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

263 Series LED Bargraph Indicator and Controllers

Measurement and Instrumentation

Series CT7N Bimetallic Overload Relays

ANALOGUE METERS FOR MARINE APPLICATIONS

Magnetic Sensor - Incremental EHP

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Micro-DCI 53ML5100 Manual Loader

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Kuhnke Technical Data. Contact Details

Magnetic and Hydraulic-Magnetic Circuit Breaker

Pulse Counters, electromechanical

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LAUREL ELECTRONICS, INC.

Product Data Sheet

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Hour Meters / Timers, electronic

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Absolute Encoders Multiturn

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Magnecraft Power Relays

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

DATA SHEET Panorama Rudder Indicator, TRI-2

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

multi-function meters

ScopeMeter 190 Series Specifications

KRF EMC Filters Installation, Operation and Maintenance Manual

Panel-mounting thermostats, type series EM

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Scanning System S-2100

02/11/2015

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Label Applicator HERMA 400

Wall-/Pipe-Mount Level Indicator

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Linear flow controls VFC Linear flow controls with actuator IFC

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Linear flow control with actuator IFC

Speed sensor MiniCoder GEL 2471

Operating instructions Electronic preset counter Type series 717

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Certificate of Calibration

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Capacitors and banks 50 Hz 0 400/415 V network voltage

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

10 PDUs 19 PDUs Zero-U PDUs

Advantech Proudly Presents Professional Monitor Series

Standard signal metering in wall-mounting case

Electronic Pulse Counter Combination device

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Type: DILM25 10(24V50HZ) Article No.:

Horn loudspeaker, Ex proof, short/long flare

Linear encoders without bearings incremental System for linear motion feedback

28 To 48 Rugged UltraWide Industrial Displays

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Absolute Rotary Encoder E6CP

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

MULTIS L72. Operating instructions

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Type: DILM12 10(24VDC) Article No.:

With 3 models available, you can choose the one that meets your needs.

Frequency Converter Fv

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Transcription:

Product Guide Analog Panel Meters for use in Electrical Engineering Systems M Series 200.U.001.05 M Series W/P/ LSP Instruments clamping to 35 mm DIN rails BWQ BGQ TP TG WQ /0S WQ /2S FQ /2 W BI BIW SY Operating Hours Counters Segmental Voltmeters with Moving-Coil Movement Null Voltmeters with Moving-Iron Movement Dual Voltmeters with Moving-Iron Movements Frequency Meters with two Vibrating Reed Movements Triple Combination Meters with Moving-Iron, Bimetallic or Bimetallic / Moving-Iron Movements Synchronoscopes DFQ WA Phase Sequence Indicators Wall Brackets, empty Synchronizing Wall Brackets

for clamping to 35 mm DIN rails Operating Hours Counters W 35 P 35 LSP 35 BWQ 48 BWQ 55 BWQ 72 BWQ 96 BGQ 48 BGQ 55 BGQ 72 BGQ 96 W 35 pivot and jewel moving - iron movement, silicon oil damped P 35 pivot and jewel moving - coil movement, core - magnet system LSP 35 pivot and jewel moving - coil movement; swivel - coil system W 35 AC current 0... 1; 1,5; 2,5; 4; 5; 6; 10; 15; 25 A * ) for use on CT 0... N / 1 A or 0... N / 5 A * ) * ) scaling to DIN series with 2x overload range 0... 100; 150; 250; 400; 500 V for use on VT 0... 100; 110 V ** ) ** )scaling to DIN series with 1.2x overload range rated frequency 50 Hz P 35 / LSP 35 DC current 0... 1; 6; 20 ma; 1; 1.5; 2.5; 4; 6 A DC voltage 0... 1; 1.5; 2.5; 4; 10; 40 V for use with 0... 60 mv or 0... 150 mv external shunt (scaling to DIN series) accuracy class 1.5 acc. to DIN EN 60 051-1 case details projecting case for clamping to 35 mm rails according to DIN EN 60 715 bar (W/P 35 with knife - edge ) deflection 0... 90 o (W/P 35), 0... 240 o (LSP 35) material of case thermoplastics, self - extinguishing colour W 35, P 35 gray (similar to RAL 7032) LSP 35 gray (similar to RAL 7035) terminals screw terminals (up to 5 mm 2 ) dimensions LxWxH W 35, P 35 75 mm x 52.5 mm x 68 mm LSP 35 95 mm x 52.5 mm x 63 mm weight approx. W 35 P 35 LSP 35 0.1 kg 0.1 kg 0.2 kg Cyclometer register driven by a wheel gearing and synchronous motor (BWQ...) stepper motor with quartz controlled electronics (BGQ... ) Counting range BGQ 48/55/72/96 000,000.0... 999,999.9 h BWQ 48/55/72/96 00,000.00... 99,999.99 h Operating voltage BWQ 48 AC 24, 115 V, 230 V BWQ 55 AC 110, 230 V, optionally 24, 48, 60 V BWQ 72 AC 110, 230 V, optionally 24, 48 V BWQ 96 AC 110, 230 V, optionally 24 V BGQ 48 DC 12... 48 V, optionally 5... 24 V, 36... 110 V BGQ 55/72/96 DC 10... 50 V = Rated frequency BWQ 50 Hz, optionally 60 Hz Indication size of numerals 4.4 mm (BWQ/BGQ 48) 4 mm (BWQ/BGQ 55/72/96) colour of numerals pre- decimal places white on black, decimal places red on black running indicator by a running gear Accuracy same as supply frequency (BWQ... ) 0.02 s in 24 h (BGQ... ) Dimensions BWQ 48 BWQ 55 BWQ 72 BWQ 96 (in mm) BGQ 48 BGQ 55 BGQ 72 BGQ 96 48 55 72 96 45 ø 50 67 90 case depth 31 58 53 53 46 ø 50 +1 68 +0.7 92 +0.7 panel thickness 1... 10 1... 10 1... 10 1... 10 60 g 60 g 140 g 180 g Front mask for Q55 bezel 55 mm x 55 mm, BWQ/BGQ 48 Q72 mask 72 mm x 72 mm, or optionally D72 mask 72 mm ø refer to Data Sheet No. 010.D.981.## refer to Data Sheet No. 040.D.100.##

Application General Data for use in switchgear, machine tools or mosaic grid panels reliable instrumentation technology for special applications in electrical engineering systems for measuring DC voltage, AC current or, supressed zero voltage, frequency, thermal maximum demand, phase comparison, phase sequence, synchronizing connection direct or for use on CT/VT Technical Data TP 96 TP 144 TP 144 Pr TG 96 TG 144 TG 144 Pr Segmental Voltmeters with Moving - Coil Movement scaling lettering and custom- logo possible to special order case complying with DIN IEC 61 554 square or rectangular form stackable suitable for use in mosaic grid panels material of case pressed steel (.Q 96/144,. 192) or thermoplastics, flame - retardant (. 144 Pr) material of window glass or as an option non - glaring glass bezel black or as an option gray position of use vertical, horizontal or to be specified between 15 to 165 o enclosure code IP 52 or as an option IP 54 splash - water protected front terminal protection protective sleeves or full sized rear cover option marine application optionally (non - certified) dimensions (in mm).q 96.Q 144. 144 Pr. 192 bezel 96 144 144 x 72 192 x 96 case 90.5 137 137 x 67 184 x 90.5 panel cutout 92 +0.8 138 +1 138 +1 186 +1.1 x 68 +0.7 x 92 +0.8 panel thickness 1... 15 * ) 1... 15 * ) 40 1... 15 1... 40 ** ) panel fixing * ) 4 pieces Weigel screw clamps ** ) 2 pieces type B screw clamps acc. to DIN 43 835 climatic suitability climatic class 2 or as an option according to climatic class 3 (limited use in the tropics) VDE/VDI 3540 sheet 2 operating temperature 25 o C... +23 o C... +40 o C (climatic class 2) range 10 o C... +23 o C... +55 o C (climatic class 3) storage temperature 25... +65 o C range relative humidity 75% annual average, non - condensing mechanical load shock 15 g or as an option 30 g, 11 ms vibration 2.5 g or as an option 5 g, 5... 55 Hz pivot and jewel moving - coil movement, electrically suppressed initial scale range; TG 96/144, TG 144 Pr rectifier incorporated DC voltage 90... 100... 110 V TP 96/144, TP 144 Pr 100... 110... 120 V 200... 220... 240 V 400... 440... 480 V 550... 600... 650 V 90... 100... 110 V TG 96/144, TG 144 Pr 100... 110... 120 V 210... 230... 250 V 360... 400... 440 V 450... 500... 550 V 550... 600... 650 V for use on VT 90... 100... 110 V TG 96/144, TG 144 Pr 100... 110... 120 V frequency range TG 40 Hz... 50 Hz... 65 Hz current consumption approx. 10mA depending on measuring range accuracy class 0.5 acc. to DIN EN 60 051-1 case details square form (TP/G 96/144) resp. rectangular form (TP/G 144 Pr) dial position horizontal dial, optionally vertical dial (TP/G 144 Pr) bar / knife- edge deflection 0... 90 o (TP/G 96/144) scale characteristics linear within measuring range; the lower voltage value is offset by approx. 8% of the scale length from scale zero value TP/G 96 TP/G 144 TP/G 144 Pr mounting depth 62 mm 60 mm 192 mm weight approx. 0.3 kg 0.6 kg 1.0 kg refer to Data Sheet No. 013.D.001.##

WQ 96 /0S WQ 144 /0S Null Voltmeters with Moving - Iron Movement 90 o - Dial WQ 96 /2S WQ 144 /2S Dual Voltmeters with two Moving - Iron Movements pivot and jewel moving - iron movement, silicon oil damped rated voltage 0... 115/230 V 0... 230/460 V 0... 400/800 V 0... 500/1000 V for use on VT 0... 100/200 V 0... 110/220 V power consumption approx. 4.2... 7.2 VA depending on rated voltage frequency range 50... 100 Hz accuracy class 1.5 acc. to DIN EN 60 051-1 bar / knife- edge deflection 0... 90 o scale characteristics initial range greatly expanded mounting depth 60 mm weight approx. WQ 96 /0S WQ 144 /0S 0.6 kg 0.7 kg 2 pivot and jewel moving - iron movements, silicon oil damped 2 x 0... 100 V 2 x 0... 110 V 2 x 0... 150 V 2 x 0... 250 V 2 x 0... 500 V 2 x 0... 600 V for use on VT 2 x 0... 100 V 2 x 0... 110 V power consumption approx. 1.8... 4.5 VA depending on rated voltage frequency range 50... 100 Hz accuracy class 1.5 acc. to DIN EN 60 051-1 deflection scale characteristics bar / knife- edge 0... 60 o practically linear down to 1 / 5 th of full - scale rating WQ 96 /2S WQ 144 /2S mounting depth 115 mm 121 mm weight approx. 1.2 kg 1.5 kg refer to Data Sheet No. 022.D.101.## refer to Data Sheet No. 023.D.101.##

FQ 96 /2 FQ 144 /2 Frequency Meters with two Vibrating Reed Movements W 192 RnS W 192 RhS BI 192 RnS BI 192 RhS BIW 192RnS BIW 192RhS Triple Combination Meters with Moving - Iron, Bimetallic or Bimetallic / Moving - Iron Movements 2 Vibrating Reed Movements. Each reed is tuned to a different value in the frequency span.. identical frequency ranges number of reeds resolution 2x 47... 50... 53 Hz 2x 13 1 Hz 2x 45... 50... 55 Hz 2x 21 1 / 2 Hz 2x 57... 60... 63 Hz 2x 13 1 Hz 2x 55... 60... 65 Hz 2x 21 1 / 2 Hz consecutive frequency ranges number of reeds resolution left 47... 50... 53 Hz and right 57... 60... 63 Hz 2x 13 1 Hz left 45... 50... 55 Hz and right 55... 60... 65 Hz 2x 21 1 / 2 Hz rated voltage 100 V up to 600 V power consumption approx. 1.1... 2.9 VA per movement depending on rated voltage accuracy class 0.5 acc. to DIN EN 60 051-1 reed arrangement vertical or as an option horizontal FQ 96 /2 FQ 144 /2 mounting depth 66 mm 58 mm weight approx. 0.65 kg 1.0 kg W 192 RnS/RhS 3 moving - iron movements (horizontal/vertical) BI 192 RnS/RhS 3 Bimetallic movements (horizontal/vertical) BIW 192 RnS/RhS 3 Bimetallic + 3 moving - iron movements (horizontal/vertical) W 192 RnS/RhS AC current 0... 100 / 200 ma up to 0... 25 / 50 A * ) ** ) for use on CT 0... N / 1 / 2 A or 0... N / 5 / 10 A * ) ** ) 0... 6 V up to 0... 600 V for use on VT 0... 100 / 120 V or 0... 110 / 132 V * ) * ) scaling to DIN series with overload range ** )optional: no overload range frequency range 50... 100 Hz or as an option calibration to a definite frequency 100... 1000 Hz BI/BIW 192 RnS/RhS AC current bimetallic 0... 1 / 1.2 A or 0... 5 / 6 A * ) moving- iron 0... 1 / 2 A 0... 5 / 10 A * ) for use on CT (scaling to DIN series) bimetallic 0... N / 1 / 1.2 A or 0... N / 5 / 6 A * ) moving- iron 0... N / 1 / 2 A 0... N / 5 / 10 A * ) * ) scaling with overload range, optionally without or with overload range 1.5 times rated current (bimetallic movement) thermal time lag 15 min or 8 min option (bimetallic movement) frequency range 50... 100 Hz or as an option calibration to a definite frequency 100... 1000 Hz accuracy acc. to DIN EN 60 051-1 bimetallic class 3 (referred to slave ) moving- iron class 1.5 mounting depth 60 mm weight approx. W 192 RnS BI 192 RnS BIW 192 RnS W 192 RhS BI 192 RhS BIW 192 RhS 0.9 kg 0.7 kg 1.0 kg refer to Data Sheet No. 031.D.101.## refer to Data Sheet No. 050.D.251.##

for Phase Comparison Synchronoscopes Phase Sequence Indicators SY 96 S SY 144 S DFQ 96 electrodynamic air - cored movement arranged as a ratio meter. The rotates over 360 o in both directions. measuring unit phase angle between two sinusoidal s indication rotating at a small difference in frequency is stationary at the 12 o clock position when phases are balanced. The will not be visible when the meter is disconnected. rated frequency 50 Hz or optionally 60 Hz rated voltage 100 V 110 V 230 V 400 V 500 V power consumption approx. generator side 0.7 VA 0.7 VA 1.5 VA 3.2 VA 3.5 VA mains side 4.0 VA 4.0 VA 5.3 VA 4.8 VA 6.7 VA rated voltage optionally 24 V, 60 V, 440 V Induction movement with a freely rotating disc. measuring unit phase sequence in three - phase systems indication disc (ø 36 mm) rotating clockwise at correct phase connection frequency range 40... 100 Hz or 400 Hz on request voltage range 100... 500 V power consumption at 100 V approx. 0.5 VA per phase at 500 V approx. 2 VA per phase safe operational period max. 5 min mounting depth weight approx. 62 mm 0.4 kg SY 96 S SY 144 S mounting depth 119 mm 117 mm weight approx. 1.0 kg 1.1 kg refer to Data Sheet No. 080.D.101.## refer to Data Sheet No. 090.D.101.##

Wall Brackets, empty Synchronizing Wall Brackets WA 96 WA 144 Application The empty wall brackets can hold three each panel meters of the standard square form 96 mm x 96 mm resp. 144 mm x 144 mm with a mounting depth of up to 150 mm / 190 mm. Indicators for synchronizing wall brackets combinations possible Synchronoscope SY 96/144 S Null Voltmeter WQ 96/144 /0S Dual Voltmeter WQ 96/144 /2S Dual Frequency Meter FQ 96/144 /2 short form data see above Mechanical Data form A wall bracket upright, support on bottom form B wall bracket suspended, support on top form C wall bracket upright, support on top and bottom (WA 144 only) form D bench- type wall bracket, support on bottom All wall brackets have a swivel range of 180 o. material case pressed steel support Al-die casting colour gray (similar to RAL 7037) fixing by 4 each screws ø10 mm weight approx. WA 96 - A/B/D WA 144 - A/B/D WA 144 - C wall bracket empty 4.5 kg 6.5 kg 7.5 kg wall bracket equipped 7 kg 10 kg 11 kg refer to Data Sheet No. 100.D.101.## Weigel Meßgeräte GmbH Postfach 720 154 90241 Nürnberg Phone: 0911/42347-0 Erlenstraße 14 90441 Nürnberg Fax: 0911/42347-39 Sales: Phone: 0911/ 42347-94 Internet: http://www.weigel messgeraete.de e mail: vertrieb@weigel messgeraete.de specifications subject to change without notice; date of issue 06/11