EndoWorld NOTES 1-E/ A Novel Port for Single Portal Laparoscopic Surgery

Similar documents
EndoWorld ORL 104-E/ Bronchoscopy Giant Optical Grasping Forceps

Laparoscopic Obesity Surgery

Mainz COLOVIEW System

KARL STORZ GI SILVER SCOPE Series

EndoWorld CARDIO-VAS 6-3-E/ Endoscopic Removal of the Radial Artery

TP /2018-E TIPCAM 1 S 3D ORL. A Dimension Ahead

Laparoscopy and Thoracoscopy in Equine Practice VET /2018-E

TP /2017-E POWER LED 300. Luminous. Efficient. Durable.

KARL STORZ SILVER SCOPE Series

In-House Training Solutions for Everyone: The concept of the European Academy for Gynaecological Surgery (EAGS)

Tele-Medicine Focusing on the future. Image and data ar Seize the

EndoWorld NEURO 3-3-E/ Neuroendoscopy. Recommended Sets acc. to GAAB

AIDA TM mini. Big Impact in a Small Package. Small, Smart and Simple

How to Chose an Ideal High Definition Endoscopic Camera System

*Please note that although this product has been approved in Japan, its launch in other countries has not yet been confirmed.

Reliability for all Laparoscopic Procedures

NAME of the products CODES. G- Cath TM EZ Delivery Catheter with Snowshoe Suture Anchors code USGI. G- Lix Tissue TM Grasper code USGI

CONTENT / INTRODUCTION VATS / MICS SHORT INTRODUCTION CONTENT

HF SURGICAL UNITS HF SURGICAL UNITS

Tender Notice No: RIMS/PUR/EQUIP/TEN-12 Tender date: 20/09/2012 Due date : 07/11/2012 ANNEXURE-A

Left to right: Dr. Anil Sharma, Dr. Vandana Soni, Dr. Pradeep Chowbey (Director), Dr. Rajesh Khullar, Dr. Manish Baijal.

Chapter Medical Table of Contents

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

Corrigendum for Two Bid Tender form for Hospital Equipment Items. (Tender ID- 827)

Overview X322BV-HD+ HDTV. LCD Panel. LED Panel. Features

What is a Visual Presenter? Flexible operation, ready in seconds. Perfect images. Progressive Scan vs. PAL/ NTSC Video

OLED. Groundbreaking technology in surgical imaging. PVM-2551MD Medical OLED Monitor

Instructions for Use: Video Inspection Scope with Display

Reusable Laparoscopic Instruments. Long-lasting performance

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

P-2 Installing the monitor (continued) Carry out as necessary

VIDEO 101 LCD MONITOR OVERVIEW

True Home Cinema Experience

KS200. Camera controller for 1 chip remote CCD cameras

FLAT DISPLAY TECHNOLOGY

SMART Board interactive whiteboard system Model SBX880i4

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

Overview X405BV-FHD HDTV. LCD Panel. LED Panel

A Live Experience with surgicam

A Live Experience with surgicam

Overview X508BV-FHD HDTV. LCD Panel. LED Panel

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

1928L Multifunction 19-inch Desktop Touchmonitor

Product Information. No High Definition Video Processor EPK-i5000

Overview X420BV-F120 HDTV. LCD Panel. LED Panel

Operating room monitor Medical-grade 4K UHD monitor

: V [p-p] (high impedance) AUDIO IN Stereo mini Jack (M3) x 1 (Shared with DVI-D IN) 0.5 V [rms] D-sub 9-pin x 1 / x 1, RS-232C Compatible

User Manual CONTENTS. Title and Contents Introduction and Warranty Section 1: General Features and Specifications... 3

Automatic Camera Tracking System

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY

SalesNews. High Speed HDMI. Vivanco High Speed HDMI cable with Ethernet, gold plated contacts, 4k/60Hz.

Overview U508CV-UMK. Display

Dell Wyse 5030 PCoIP Zero Client

UNITS GERÄTE.

TH-55LF80U. 55-inch Class FULL HD LCD Display. Product specification (design and specification subject to change without notice) DISPLAY PANEL

MDSC-2232 Full HD 32-inch surgical display

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

BFW LIGHTING SOLUTIONS GUIDE. Hospitals are switching to BFW

TH-42LF80U. 42-inch Class FULL HD LCD Display. Product specification (design and specification subject to change without notice) DISPLAY PANEL

V R171P-HDA R171P-HDA

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Video to SXGA Converter Box ID#475

USER GUIDE FOR NETmc MARINE X-Ops

Overview U500CV-UMK. Display

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER

LD-V4300D DUAL STANDARD PLAYER. Industrial LaserDisc TM Player

Gazer VI700A-SYNC/IN and VI700W- SYNC/IN INSTALLATION MANUAL

QuickSpecs. Models RB146AA#ABA Standard Configuration RB146AT#ABA Promotional Part Number (SmartBuy) HP L5006tm 15-inch LCD Touchscreen Monitor

55-inch Class FULL HD LCD Display TH-55SF1HW

MON3-2W/HR MON4-2W/HR (Document P/N Rev-B)

FM-24.

Sony Presentation Solutions Pocket Guide CHANGING THE WAY BUSINESS IT S SO HARD TO CHOOSE UNLESS YOU HAVE ALL THE FACTS. COMMUNICATES.

A Perfect Solution for Digital Signage in Commercial Areas CDE4600-L

Photoelectrics Through-beam Type PA18C.T..., DC

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RTBUS-12 Round Table Connection Bus. P/N: Rev 1

3,000 Lumens WXGA Short Throw LightStream Projector

Overview U438CV-UMC. Display

CORIO master C3-540 Series

STAHL ENDOSCOPY ARTHROSCOPY

Datasheet EC-750 Ex DOME Camera

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

Advantech Proudly Presents Professional Monitor Series

Specifications SMART Hub SE240 with SMART Board SB680i2. Model SB680i2-SE240. Physical Specifications. SMART Board 680 Interactive Whiteboard

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

User Manual CONTENTS. Title and Contents Important Safety Instructions and Introduction... 2

PROFESSIONAL D-ILA PROJECTOR DLA-G11

Optoma DLP Projector

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

SMART Board interactive whiteboard system Model 680i5

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

Chapter 10. SDI & HD-SDI SWITCHERS MSW 4V SDI rs Four Input SDI Video Switcher SW4 3G HD-SDI Four Input Multi-Rate SDI Switcher...

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Camera Setup Instructions

- CORRIGENDUM V

PPM63H3Q PPM50H3Q. PPM42H3 42" HD 1024 x 768 Resolution PPM42S3Q 42" SD 852 x 480 Resolution

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

Transcription:

EndoWorld NOTES 1-E/04-2010 A Novel Port for Single Portal Laparoscopic Surgery

S-Portal Single Portal Laparosopic Surgery Single Portal (S-PORTAL) Laparoscopic Surgery is the natural extension of traditional multi-incision laparoscopic surgery in the quest for reduction of surgical trauma and residual scarring to the patient. It also represents an alternative approach to Natural Orifice Translumenal Endoscopic Surgery (NOTES) over which it has certain important and practical advantages: Surgeons are more familiar with the technique as it differs little for the traditional multi-port laparoscopic surgery The technologies required for the S-PORTAL approach including rigid telescopes and instruments with minor modification are available The S-PORTAL approach enables execution of operations in the various specialties: general surgery, gynecology and urology The S-PORTAL approach enables execution of major intra-abdominal operations, e.g., liver resections, colonic resections, splenectomies, pancreatic resections, nephrectomies, hysterectomies etc. Fig. 1

2 3 The idea of S-PORTAL through a single dedicated port is not new since it was first introduced and practiced by the late Austrian endoscopic surgeon R. Wittmoser in the 1970s for operative thoracoscopic interventions on the autonomic nervous system. Unfortunately, this development has been marred by a lack of an agreed scientificfic nomenclature with a resulting profusion of terms/acronyms, e.g., Laparo-Endoscopic Single Site (LESS) Surgery, One Port Umbilical Surgery (OPUS), Natural Orifice Trans-Umbilical Surgery (NOTUS), trans-umbilical E-NOTES etc., none of which are semantically accurate. Despite potential advantages, the S-Portal technique imposes major ergonomic restrictions and limitations such that the level of difficulty of executing laparo - s copic procedures through this approach is much higher and the surgeon needs to be experienced in traditional multi-port laparoscopic surgery. The ENDOCONE S-Portal system (Fig. 1) was developed as a holistic solution (port-instruments-retraction system) for S-Portal to overcome these problems and to facilitate the execution of operations by this approach. The use of proximally deviating curved coaxial instruments increases the operative space between the surgeon s hands during SPLS and facilitates the performance of various surgical procedures, e.g., cholecystectomy, colectomy, nephrectomy etc. (Fig. 2). Fig. 2

Introduction Introduction Materials Materials Technique Technique Conclusion Conclusion Instrumentation Instrumentation Materials Although standard 10 mm 30 scopes can be used, the recommended extra-long 5 mm telescope (Fig. 3) or the ENDOCAMELEON (Fig. 4) are reducing the risk of instrument collisions and creates the perfect conditions for an optimal image quality and ergonomic working conditions. The associated 90 light cable connector helps to reduce clashing between the operating instruments and the light cable. Whereas standard laparoscopic units might be used for Single Portal Surgery we recommend the use of an Image 1 HD system due to the brilliant image quality and the wide screen picture which is extremely helpful for Single Portal Surgery. Fig. 3 Fig. 4 Fig 3: Extra-long 5 mm 30 endoscope Fig 4: The Endocameleon (variable direction of view, 0 120 ) Fig. 5 Fig. 5: S-Portal equipment mounted on a videocart

4 5 The DUNDEE ENDOCONE All the available S-PORTAL access port devices are disposable being constructed from flaccid polymers. The Dundee Group developed the only reusable operating system, the ENDOCONE system, manufactured from stainless steel with a design that facilitates both insertion and retention within the anterior abdominal wall. Additionally the system includes coaxially curved instruments designed to facilitate triangulation, provide traction and counter-traction during dissection of tissue planes and maximize their range of motion within the operating space. The ENDOCONE was designed to enable instrument triangulation, albeit reduced from the ideal 60 to 30 because of the imposed restricted space imposed by the access port. To achieve this, the shape of the port is complex and consists of a proximal section (cone) leading to a short cylindrical section for negotiation through the abdominal wall and having an outer diameter of 35 mm. This cylindrical section has a protruding rim feature of sufficient width which aids insertion of the ENDOCONE (by a clockwise movement) and ensures secure retention within the abdominal wall (Figure 6). Fig. 6 Figure 6: Dundee ENDOCONE showing protruding rim feature which aids insertion and retention of the device.

Introduction Introduction Materials Materials Technique Technique Conclusion Conclusion Instrumentation Instrumentation The actual insertion is accomplished by placing the leading edge of the thread through the umbilical wound and turning through one clockwise revolution, after which the complete lip will have negotiated the full thickness of the abdominal wall into the peritoneal cavity. The proximal conical section of the ENDOCONE is capped with a separate seal cap (bulkhead) which houses 8 valved instrument seals (Fig. 7 a): two along large midline (for instruments up to 15 mm in diameter) and 6 (three on either side) for instruments up to 5 mm in diameter). Fig. 7a Fig. 7b Fig. 7c Fig. 7: A seal cap with valved inlets locked in ENDOCONE (7a), detachment of seal cap (7b and c), specimen extraction through ENDOCONE (7c). The seal cap is removed by an anti-clockwise movement from the ENDOCONE for extraction of specimen.

Introduction Materials Technique Conclusion Instrumentation 4 5 6 7 The CUSCHIERI Coaxial Deviating Instruments The CUSCHIERI coaxial deviating instruments (Fig.8, 9) are specifically designed to be used during S-Portal with the ENDOCONE port. The ENDOCONE S-PORTAL Operating system comes with a basis set of curved instruments. In addition a supplemental set of instruments is available for execution of major operations with the ENDOCONE S-PORTAL approach. Fig. 8a Fig. 8b Fig 8: The Cuschieri coaxial deviating instruments

These are based on the Cuschieri s coaxial curved instruments but have been specifically modified for use during S-PORTAL with the ENDOCONE port. Their main characteristics are: Straight ergonomic axial handle with integrated mono-polar energy connection that allows ergonomic manipulation of the instruments following insertion, thus reducing surgeon s discomfort Distal and proximal curvatures: the former enhances internal manipulations and the latter increases the operative space between the surgeon s hands The curve design allows the surgeon to achieve acceptable intracorporeal triangulation and a comfortable, ergonomic position without intrusion into the operating work space of the camera person. By virtue of the cut out by the leading flange of the screw, the surgeon can increase the excursion of the operating and assisting instruments by rotation of the ENDOCONE so that one instrument can be accommodated in the notch during manipulation (Fig. 9). Fig. 9a Fig. 9b Fig. 9c Fig. 9d Fig. 9: llustration of how the surgeon can increase the distance between two operating instruments by rotation of ENDOCONE so that one instrument is accommodated in notch. Another way is to use a crossed instrument configuration with the instruments crossing each other inside the port.

8 9 Insertion of the ENDOCONE The pneumoperitoneum can be induced by either the closed (Veress needle) or open technique according to surgeon s preferences. A 5 or 10 mm port is inserted through a vertical mid-line incision at the upper margin of the umbilicus and the peritoneal cavity is explored to evaluate the feasibility of S-Portal approach. If this is the case, the incision in enlarged up to 30 35 mm along the midline through the umbilicus into the peritoneal cavity. We recommend the insertion of a plastic wound protector through the incision as this improves the stability of the ENDOCONE and provides wound protection during the extraction of large specimens (Fig. 10). Fig. 10a Fig. 10b Fig.10.c Fig 10: Introduction of a wound protector through a 30 mm incision

The ENDOCONE can now be inserted using a corkscrew -clockwise movement (Fig. 11). Fig. 11a Fig. 11b Fig 11: Insertion of the ENDOCONE Fig. 11c Thereafter the abdomen is insufflated through the dedicated stopcock on the port and the instruments are inserted. It is recommended that the stopcock value should be at the 9 o clock position at the start of the operation. The visual position of the stopcock also helps to identify the intraabdominal position of the leading flanche.

10 11 Insertion of Telescopes and Instruments The ENDOCONE allows the insertion of either a 5 or 10 mm laparoscope together with up to 3 working straight or coaxial curved instruments simultaneously; furthermore the two central (upper and lower) 10 13 mm valves also allow the insertion of endoscopic surgical staplers (Fig. 12). Fig. 12a Fig. 12b Fig. 12a Fig. 12: Insertion of instruments through the ENDOCONE

Introduction Materials Introduction Technique Materials Conclusion Technique Instrumentation Conclusion Instrumentation 8 9 Fig.13a Fig. 13c Fig. 13b Fig. 13d Fig. 13: Three instruments in simultaneous use (Fig 13a, b); Stapler introduction during S-Portal (Fig. 13c, d) The introduction of curved instruments is facilitated by a gentle rotational clockwise movement for negotiating passage through ENDOCONE. The curved instruments should slide into the abdominal cavity with this technique. At no point must the curved instruments be forced through when passage is prevented by impingement on the walls of the ENDOCONE as such force will damage the insulation of the instruments. All the surgeon has to do in this situation is to rotate the instrument clockwise or anti-clockwise during gentle pushing, when the instrument will glide through the ENDOCONE without sustaining any damage.

12 13 Use of Coaxial Deviating Instruments The instrument sets for ENDOCONE S-Portal are available as a basic set but can be customized by a supplementary instrument list in accordance with the surgeon s personal preferences and needs. Nevertheless the use of coaxial proximally deviating instruments allows the surgeon to achieve acceptable triangulation which is not possible with other devices for single port surgery, especially when straight instruments are used. Indeed, according to the specific procedures and situations as well as surgeon s preferences, a combination of curved and straight shaft may be the correct choice. Fig. 14a Fig. 14b Fig. 14c Fig 14: Told s fascia blunt dissection during S-Portal right hemicolectomy using two coaxial curved forceps. Note how the curvature of the shafts enables good triangulation and optimal viewing The curvature can also be used to arch over foreground structures to reach the desired anatomical structure, to lift and tent tissues, obtain triangulation and the back of the curvature for atraumatic blunt dissection of tissue planes (Fig. 14 16).

Introduction Materials Introduction Technique Materials Conclusion Technique Instrumentation Conclusion Instrumentation 10 11 Fig. 15a Fig.15b Fig. 15c Fig. 15d Fig. 15: Mobilization of the right colon using curved instruments Fig. 16a Fig. 16b Fig. 16: Dissection round the renal artery (a) and vein (b) during single port right nephrectomy

14 15 End of the Procedure and Removal of the ENDOCONE Once the procedure is completed the cap valve of the ENDOCONE is unscrewed and the specimen (if small) extracted, using the cone itself as wound protector (Fig. 17). However if the specimen is bulky, it is best to remove the ENDCONE by an anti-clockwise rotation leaving the wound protector in-situ. In this case, the ENDOCONE is re-inserted and abdomen insufflated to enable final check of the operative field. Fig. 17a Fig. 17b Fig. 17: Removal of the cap and extraction of the specimen At the end of the procedure the peritoneal, musculofascial and skin layers are closed, using non-absorbable sutures for the fascial layer. Because of the natural shape of the umbilical pit, the cosmetic results are excellent (Fig. 18) Fig. 18a Fig. 18b Fig. 18c Fig. 18: Final cosmetic results after S-Portal in case of right hemicolectomy (Fig. 18 a,b) and Splenectomy (Fig. 18c)

Conclusion Single Portal Laparoscopic Surgery represents an additional challenge to surgeons and requires dedicated technology which reduces the risk of instruments clashing and restores the ergonomic working conditions of standard multi-port laparoscopic surgery. The ENDOCONE system with its dedicated set of coaxially curved instruments greatly facilitates the safe execution of operations by the S-Portal approach. Professor Sir Alfred Cuschieri Ninewells Hospital and Medical School University of Dundee Department of Surgery Professor Luigi Boni Ospedale di Circolo di Varese University of Varese Department of Surgery References 1. Ha nn a GB, Sh i m i S, Cuschier i A: Influence of direction of view, target-to-endoscope distance and manipulation angle on endoscopic knot tying. British Journal of Surgery. 1997; 84(10): 1460-4. 2. Cuschieri A, Sh i m i S, Ba nting G, Va nder-velpen G, Dunk le y P: Coaxial curved instruments for minimal access surgery. End Surg 1993; 1: 303-5.

16 17 Instrumentation HOPKINS Telescope 26048 BA hr Forward-Oblique Telescope 30, diameter 5.5 mm, length 50 cm, autoclavable 495 EW Light Adapter, diameter 4.8 mm, 90 angled, free rotatable, to connect with standard scopes Wound Protector-Retractor (e.g. Alexis/Applied Medical) Single Port Access System 23010 PA ENDOCONE Single Portal Surgery Access System (size 34 mm) consisting of: 23010 P Port, size 34 mm 23010 SA Gasket, with 1 x 10 mm, 1 x 10-15 mm and 6 x 3-5 mm ports 23001 DB Reducer, 13/ 5 mm and 11/ 5 mm 23005 ID LUER-Lock-Connector with stopcock for insufflation and desufflation

Instruments Set of standard straight 5 mm KARL STORZ Instruments (with insulated handles with connector pin for unipolar coagulation: No. 33127, including: 34327 MS c METZENBAUM Scissors, rotating, curved, length of blades 12 mm, size 5 mm, length 36 cm, double action jaws 33327 ON c Grasping Forceps, rotating, size 5 mm, length 36 cm, atraumatic, fenestrated, single action jaws 33327 CC c CROCE-OLMI Grasping Forceps, rotating, size 5 mm, length 36 cm, atraumatic, fenestrated, curved, single action jaws 33327 A c BABCOCK Grasping Forceps, rotating, size 5 mm, length 36 cm, double action jaws 33327 C c Bowel Grasper, rotating, size 5 mm, length 36 cm, fenestrated, double action jaws 33327 ML c KELLY Dissecting and Grasping Forceps, long, rotating, size 5 mm, length 36 cm, double action jaws 33327 R c Dissecting and Grasping Forceps, rotating, size 5 mm, length 36 cm, right angled, double action jaws 26775 UF Coagulating and Dissecting Electrode, L-shaped, size 5 mm, working length 36 cm

18 19 Set of co-axial 5 mm KARL STORZ Instruments (with insulated handles with connector pin for unipolar coagulation No. 33127 P, including: 23262 MSA c METZENBAUM Scissor, curved, length of blades 12 mm, double action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 36 cm 23162 ONA c Grasping Forceps, fenestrated, with especially fine atraumatic serration, single action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 36 cm 23162 DFA c Dissecting and Grasping Forceps, atraumatic, double action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 36 cm 23162 CCA c CROCE-OLMI Grasping Forceps, atraumatic, fenestrated, curved, single action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 36 cm 23162 AA c BABCOCK Grasping Forceps, atraumatic, fenestrated, double action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 36 cm 23162 MLA c KELLY Dissecting and Grasping Forceps, long, double action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 36 cm 23162 RA c Dissecting and Grasping Forceps, right angled, double action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 36 cm 23870 UFA Coagulating and Dissecting Electrode, L-shaped tip, sheath bending according to CUSCHIERI, size 5 mm, working length 36 cm

Introduction Materials Materials Technique Conclusion Instrumentation 23262 MSI c METZENBAUM Scissor, curved, length of blades 12 mm, double action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 43 cm 23162 DFI c Dissecting and Grasping Forceps, atraumatic, double action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 43 cm 23162 MLI c KELLY Dissecting and Grasping Forceps, long, double action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 43 cm 23162 RI c Dissecting and Grasping Forceps, right angled, double action jaws, sheath bending according to CUSCHIERI, size 5 mm, working length 43 cm 23162 BAI c BABCOCK Grasping Forceps,atraumatic, jaws with multiple teeth, single action jaws, sheath bending according to CUSCHIERI, size 5mm, working length 43 cm 23870 UFI Coagulating and Dissecting Electrode, L-shaped tip, sheath bending according to CUSCHIERI, size 5 mm, working length 43 cm

20 21 KARL STORZ AIDA compact NEO (HD/SD) Brilliance in documentation continues! Features and Benefits ## Digital storage of still images with a resolution of 1920 x 1080 pixels, video sequences in 720p and audio files with AIDA compact NEO HD ## Optional interface package DICOM/HL7 ## Sterile, ergonomic operation via touch screen, voice control, camera head buttons and/or foot switches ## Auto detection of the connected camera system on HD-SDI/SD-SDI input ## Efficient archiving on DVD, CD-ROM or USB stick, multi-session and multi-patient ## Network saving ## Automatic generation of standard reports ## Approved use of computers and monitors in the OR environment as per EN 60601-1 ## Compatibility with the KARL STORZ Communication Bus (SCB) and with the KARL STORZ OR1 AV NEO ## KARL STORZ AIDA compact NEO HD/SD is an attractive, digital alternative to video printers, video recorders and dictaphones. 20 0409 10 KARL STORZ AIDA compact NEO SD Communication, documentation system for digital storage of still images, video sequences and audio files, power supply 115/230 VAC, 50/60 Hz 20 0409 11 KARL STORZ AIDA compact NEO HD Communication, documentation system for digital storage of still images, video sequences and audio files, power supply 115/230 VAC, 50/60 Hz 20 0406 10 KARL STORZ AIDA compact NEO SD, documentation system for digital storage of still images, video sequences and audio files, power supply 115/230 VAC, 50/60 Hz 20 0406 11 KARL STORZ AIDA compact NEO HD, documentation system for digital storage of still images, video sequences and audio files, power supply 115/230 VAC, 50/60 Hz Specifications: Video Systems Signal Inputs Image Formats - PAL - NTSC - S-Video (Y/C) - Composite - RGBS - SDI - HD-SDI - DVI - JPG - BMP Video Formats Audio Formats Storage Media - MPEG2 - WAV - DVD+R - DVD+RW - DVD-R - DVD-RW - CD-R - CD-RW - USB stick

Introduction Materials Materials Technique Conclusion Instrumentation 16 17 IMAGE 1 HD HD hub Camera Control Unit Maximum resolution and the consistent use of the 16:9 aspect ratio guarantee FULL HD Endoscopic camera systems have to be equipped with three-ccd chips that support the 16:9 input format as well as capturing images with a resolution of 1920 x 1080 pixels The benefits of High Definition Technology (HD) for medical applications are Up to 6 times* higher input resolution of the camera delivers more detail and depth of focus Using 16:9 format during image acquisition enlarges the field of vision and supports ergonomic viewing The brilliance of color enables optimal diagnosis Lateral view is enhanced by 32% when the endoscope is withdrawn slightly, providing the same image enhancement as a standard system. Any vertical information loss is restored and the lens remains clean 22 2010 11U102 IMAGE 1 HUB HD Camera Control Unit (CCU) with SDI Module 22 2010 20-1xx for use with IMAGE 1 HD and standard one- and three-chip camera heads, max. resolution 1920 x 1080 Pixel, with integrated KARL STORZ SCB and integrated digital Image Processing Module, color systems PAL/NTSC, power supply 100 240 VAC, 50/60 Hz consisting of: 22 2010 20-102 IMAGE 1 HUB HD (with SDI) Camera Control Unit 400 A Mains Cord 3 x 536 MK BNC/BNC Video Cable, length 180 cm 547 S S-Video (Y/C) Connecting Cable, length 180 cm 20 2032 70 Special RGB Connecting Cable 2x 20 2210 70 Connecting Cable, for controlling peripheral units, length 180 cm 20 0400 86 DVI Connecting Cable, length 180 cm 20 0901 70 SCB Connecting Cable, length 100 cm 20 2001 30U Keyboard, with English character set Specifications: Signal-to-noise ratio AGC Video output Input IMAGE 1 HUB HD Three-chip camera systems M 60 db Micro - processorcontrolled - Composite signal to BNC socket - S-Video signal to 4-pin Mini DIN socket (2x) - RGBS signal to D-Sub socket - SDI signal to BNC socket (only IMAGE 1 HUB HD with SDI module)(2x) - HDTV signal to DVI-D socket (2x) Keyboard for title generator, 5-pin DIN socket Control output /input - KARL STORZ-SCB at 6-pin Mini DIN socket (2x) - 3.5 mm stereo jack plug (ACC 1, ACC 2), - Serial port at RJ-11 - USB port (only IMAGE 1 HUB HD with ICM) (2x) Dimensions w x h x d (mm) Weight (kg) Power supply Certified to: 305 x 89 x 335 2.95 100-240 VAC, 50/60 Hz IEC 601-1, 601-2-18, CSA 22.2 No. 601, UL 2601-1 and CE acc. to MDD, protection class 1/CF SDI Serial Digital Interface: optimized to display medical images on Flat Screens, Routing with OR1 and digital recording with AIDA-DVD-M ICM: USB-connector for recording video streams and stills on USB storage media or for connection of USB printers for direct printing of the recorded stills

22 23 IMAGE 1 HD HD Camera Head 22 2200 55-3 22 2200 55-3 50 Hz IMAGE 1 H3-Z, 60 Hz Three-Chip HD Camera Head max. resolution 1920 x 1080 pixels, progressive scan, soakable, gas and plasma sterilizable, with integrated Parfocal Zoom Lens, focal length f = 15 31 mm (2x), 2 freely programmable camera head buttons, for use with color system PAL/NTSC Specifications: Image sensor Pixel output signall H x V Dimensions Weight Min. sensitivity Lens Grip mechanism Cable Cable length 3x 1 /3" CCD-Chip 1920 x 1080 Diameter 32-44 mm, length 114 mm 246 g F 1,4/1,17 Lux Integrated Parfocal Zoom Lens, f = 15-31 mm Standard eyepiece detector, non-detachable 300 cm KARL STORZ HD Flat Screens Color systems PAL/NTSC Version Order No. Screen diagonal Max. screen resolution 1920 x 1200 Composite signal to BNC socket S-Video to 4-pin Mini DIN socket RGB to Video input VGA to 15-pin HD-D-Sub socket 5x BNC socket SDI to BNC socket HD-SDI to BNC socket DVI to DVI-D socket Wall mounted with VESA 100-adaption 9524 NB 9526 NB 24" 26" Desktop with pedestal 9524 N 9526 N 24" 26" l l l l l l l l The following accessories are included: 400 A Mains Cord 9523 PS External 24VDC Power Supply 9419 SF Pedestal

www.karlstorz.com EndoWorld Karl Storz GmbH & Co. KG Mittelstraße 8, 78532 Tuttlingen, Germany Postfach 230, 78503 Tuttlingen, Germany Phone: +49 (0)7461 708-0 Fax: +49 (0)7461 708-105 E-Mail: info@karlstorz.de www.karlstorz.com KARL STORZ Endoscopy-America, Inc. 2151 East Grand Avenue El Segundo, CA 90245-5017, USA Phone: +1 424 218-8100, +1 800 421-0837 Fax: +1 424 218-8526 E-Mail: info@ksea.com EW MDM 2-E/03-2010