SFA-1000 SFA User's guide

Similar documents
User's guide SFA-5000 SFA Absolute draw-wire encoder. Analogue version. Smart encoders & actuators

SME11 SME21 SME51. User's guide

AS36 ASC36. User's guide

IP58, IP58S, CKP58 IQ58, IQ58S, CKQ58 IQ36, CKQ36

Smart encoders & actuators

Encoders. for Robotic Systems, Motors & OEM Applications

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Gurley Models LA18, LA20, LA25, High Resolution - Industrial Ruggedness

ASR58 ASR58S ASRC. User's guide

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Ø50mm Shaft Multi-Turn Absolute Type

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

Absolute Encoders Multiturn

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

MICROMASTER Encoder Module

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

ENC - LKE51 - L I B

Colour Explosion Proof Video Camera USER MANUAL VID-C

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

Linear encoders without bearings incremental System for linear motion feedback

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Netzer AqBiSS Electric Encoders

C200H-AD002/DA002 Analog I/O Units Operation Guide

Photovoltaic Module Installation Manual (IEC)

OM2000N INSTALLATION MANUAL

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

ODW-621. RS-232 Point-to-point applications

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Installation Guide VL-MV10. Model No.

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

SM-UNIVERSAL ENCODER PLUS

Absolute Linear Encoder

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Photovoltaic Module Installation Manual (IEC)

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

SM-Universal Encoder Plus. EF User Guide. Solutions module for Unidrive SP

Spectra Batten (Order code: LEDJ95)

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

S6-R READER. Installation and Operating Instructions

Type SCH94FO. Type SCH94FO. Description

TVAC20000 User manual

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Speed sensor MiniCoder GEL 2471

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

DMX 512 Language Date: Venerdì, febbraio 12:15:08 CET Topic: Educational Lighting Site

Fibre Optic Modem ODW-622

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

IV 251. Signal Converter SSI Analogue and SSI Serial. Operating Instructions. control motion interface

3 Cleaning. 4 Technical data

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

Continuous Flex Data Cable

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

VLT AutomationDrive FC 301/FC 302

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS

EBU INTERFACES FOR 625 LINE DIGITAL VIDEO SIGNALS AT THE 4:2:2 LEVEL OF CCIR RECOMMENDATION 601 CONTENTS

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Absolute encoders multiturn

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Capacitance Level Measurement Electronic insert FEC 12

Material: Weight: IP Rating: Cable: Connector:

Power Injector 1520 Series

It will cause malfunction if the monitor is operating with unspecified power supply

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

Innovation in Magnetic Measuring Instruments. Operation Manual for. Mag648 and Mag649 Low Power Three-Axis Magnetic Field Sensors.

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

EZ-LIGHT K30L Series With Independent Push Button Contact

ENC-CK58SN-L R-L1

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

Cables for robot applications

EM1. Transmissive Optical Encoder Module Page 1 of 9. Description. Features

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

3G/HD/SD-SDI to HDMI Converter

SQM40/41 Actuators for air and gas dampers

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Transcription:

Smart encoders & actuators User's guide SFA-1000 SFA-2000 Miniature absolute draw-wire encoder Absolute draw-wire encoder with SSI interface Robust and compact design Resolution from 0.1 mm to 0.012 mm Max. measuring length 1000mm (SFA-1000) e 2000mm (SFA-2000) Cable and M12 connector outputs Suitable for the following models: SFA-1000-BA-... SFA-1000-GA-... SFA-2000-BA-... SFA-2000-GA-... General Contents Preliminary information 5 Safety summary 6 Identification 8 Mechanical installation 9 Electrical connection 13 SSI interface 17 Lika Electronic Tel. +39 0445 806600 info@lika.biz www.lika.biz

This publication was produced by Lika Electronic s.r.l. 2017. All rights reserved. Tutti i diritti riservati. Alle Rechte vorbehalten. Todos los derechos reservados. Tous droits réservés. This document and information contained herein are the property of Lika Electronic s.r.l. and shall not be reproduced in whole or in part without prior written approval of Lika Electronic s.r.l. Translation, reproduction and total or partial modification (photostat copies, film and microfilm included and any other means) are forbidden without written authorisation of Lika Electronic s.r.l. The information herein is subject to change without notice and should not be construed as a commitment by Lika Electronic s.r.l. Lika Electronic s.r.l. reserves the right to make all modifications at any moments and without forewarning. This manual is periodically reviewed and revised. As required we suggest checking if a new or updated edition of this document is available at Lika Electronic s.r.l.'s website. Lika Electronic s.r.l. assumes no responsibility for any errors or omissions in this document. Critical evaluation of this manual by the user is welcomed. Your comments assist us in preparation of future documentation, in order to make it as clear and complete as possible. Please send an e-mail to the following address info@lika.it for submitting your comments, suggestions and criticisms.

General contents User's guide...1 General contents...3 Typographic and iconographic conventions...4 Preliminary information...5 1 Safety summary... 6 1.1 Safety...6 1.2 Electrical safety...6 1.3 Mechanical safety...7 2 Identification... 8 3 Mechanical installation... 9 3.1 Overall dimensions...9 3.2 Mounting instructions...10 3.3 Useful information...11 3.4 Maintenance...12 4 Electrical connection... 13 4.1 Cable and connectors connections...13 4.2 M8 cable specifications...13 4.3 M12 8-pin connector specifications...14 4.4 Connection of the shield...14 4.5 Ground connection...14 4.6 Zero setting input...15 4.7 Counting direction input...16 5 SSI interface... 17 5.1 SSI (Synchronous Serial Interface)...17 5.2 LSB Right Aligned protocol...18 5.3 Recommended transmission rates...21 5.4 Max. speed and counting frequency...22 5.5 Recommended SSI circuit...23

Typographic and iconographic conventions In this guide, to make it easier to understand and read the text the following typographic and iconographic conventions are used: parameters are coloured in GREEN; alarms are coloured in RED; states are coloured in FUCSIA. Some icons in the pages are expressly designed to highlight the parts of the text which are of great interest and significance for the user. Sometimes they are used to warn against dangers or potential sources of danger arising from the use of the device. You are advised to follow strictly the instructions given in this guide in order to guarantee the safety of the user and ensure the performance of the device. In this guide the following symbols are used: This icon, followed by the word WARNING, is meant to highlight the parts of the text where information of great significance for the user can be found: user must pay the greatest attention to them! Instructions must be followed strictly in order to guarantee the safety of the user and a correct use of the device. Failure to heed a warning or comply with instructions could lead to personal injury and/or damage to the unit or other equipment. This icon, followed by the word NOTE, is meant to highlight the parts of the text where important notes needful for a correct and reliable use of the device can be found. User must pay attention to them! Failure to comply with instructions could cause the equipment to be set wrongly: hence a faulty and improper working of the device could be the consequence. This icon is meant to highlight the parts of the text where suggestions useful for making it easier to set the device and optimize performance and reliability can be found. Sometimes this symbol is followed by the word EXAMPLE when instructions for setting parameters are accompanied by examples to clarify the explanation.

Preliminary information This guide is designed to provide the most complete and exhaustive information the operator needs to correctly and safely install and operate the SFA-1000 and SFA-2000 absolute draw-wire encoders. SFA-1000/SFA-2000 cable-pulling encoder is aimed at speed and position measurements and controls in a variety of industrial applications through the movement of a 1,000 mm (39.37 ) or 2,000 mm (78.74 ) stainless steel wire. The typical back and forth travel of the moving equipment causes the wire to reel and unreel and thus the linear movement to be converted into a rotative motion detected by the encoder which is coupled to the drum. SFA-1000/SFA-2000 provides the absolute position information through the LSB Right Aligned protocol SSI interface. To make it easier to read and understand the text, this guide is divided into two main sections. In the first section some general information concerning the safety, the mechanical installation and the electrical connection as well as tips for setting up and running properly and efficiently the SFA- 1000/SFA-2000 cable-actuated encoder are provided. In the second section, entitled SSI Interface, you can find detailed information on the SSI interface.

1 Safety summary 1.1 Safety Always adhere to the professional safety and accident prevention regulations applicable to your country during device installation and operation; installation and maintenance operations have to be carried out by qualified personnel only, with power supply disconnected and stationary mechanical parts; device must be used only for the purpose appropriate to its design: use for purposes other than those for which it has been designed could result in serious personal and/or the environment damage; high current, voltage and moving mechanical parts can cause serious or fatal injury; warning! Do not use in explosive or flammable areas; failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the equipment; Lika Electronic assumes no liability for the customer's failure to comply with these requirements. 1.2 Electrical safety Turn OFF power supply before connecting the device; connect according to explanation in the Electrical connection section; connect Zero setting input to 0Vdc, if not used; to zero set the encoder, connect Zero setting to +Vdc for 100 µs at least, then disconnect +Vdc; normally voltage must be at 0Vdc; zero set must be performed after Counting direction; we suggest performing the zero set when the encoder is in stop; connect Counting direction input to 0Vdc, if not used; to have count up information when pulling the wire out = connect the input to 0Vdc; to have count up information when rewinding the wire = connect to +Vdc; in compliance with 2014/30/EU norm on electromagnetic compatibility, following precautions must be taken: - before handling and installing the equipment, discharge electrical charge from your body and tools which may come in touch with the device; - power supply must be stabilized without noise; install EMC filters on device power supply if needed; - always use shielded cables (twisted pair cables whenever possible); MAN SFA_1000_2000 SSI E 1.2 Safety summary 6 of 24

- avoid cables runs longer than necessary; - avoid running the signal cable near high voltage power cables; - mount the device as far as possible from any capacitive or inductive noise source; shield the device from noise source if needed; - to guarantee a correct working of the device, avoid using strong magnets on or near by the unit; - minimize noise by connecting the shield and/or the connector housing and/or the frame to ground. Make sure that ground is not affected by noise. The connection point to ground can be situated both on the device side and on user s side. The best solution to minimize the interference must be carried out by the user. 1.3 Mechanical safety Install the device following strictly the information in the Mechanical installation section; mechanical installation has to be carried out with stationary mechanical parts; do not disassemble the unit; do not tool the unit; delicate electronic equipment: handle with care; do not subject the device to knocks or shocks; respect the environmental characteristics of the product; we suggest installing the unit providing protection means against waste, especially swarf as turnings, chips, or filings; should this not be possible, please make sure that adequate cleaning measures are in place in order to prevent the wire from jamming; to avoid failures, never exceed the maximum measuring length and prevent the wire from tangling up; never release the wire freely, always help the wire wind properly: risk of personal injury and/or equipment damage; always keep the wire aligned not to damage the equipment; the stroke per turn of the draw-wire unit is 100 mm (3.937 ). MAN SFA_1000_2000 SSI E 1.2 Safety summary 7 of 24

2 Identification Device can be identified through the order code and the serial number printed on the label applied to its body. Information is listed in the delivery document too. Please always quote the order code and the serial number when reaching Lika Electronic. For any information on the technical characteristics of the product refer to the technical catalogue. Warning: encoders having order code ending with "/Sxxx" may have mechanical and electrical characteristics different from standard and be supplied with additional documentation for special connections (Technical Info). MAN SFA_1000_2000 SSI E 1.2 Identification 8 of 24

3 Mechanical installation WARNING Installation has to be carried out by qualified personnel only, with power supply disconnected and mechanical parts compulsorily in stop. 3.1 Overall dimensions Values are expressed in mm MAN SFA_1000_2000 SSI E 1.2 Mechanical installation 9 of 24

3.2 Mounting instructions Fasten the draw-wire unit onto a fixed support using two M3 screws 1; remove the transport safety wire that pins the end of the measuring wire; fix the end of the measuring wire to the moving element using the provided M6 nuts 2. WARNING We suggest installing the unit providing protection means against waste, especially swarf as turnings, chips, or filings; should this not be possible, please make sure that adequate cleaning measures are in place in order to prevent the wire from jamming. To avoid irreparable failures, never exceed the maximum measuring length and prevent the wire from tangling up. Never release the wire freely, always help the wire wind properly: risk of personal injury and/or equipment damage. MAN SFA_1000_2000 SSI E 1.2 Mechanical installation 10 of 24

Always keep the wire aligned not to damage the equipment (maximum deviation: 3 ). 3.3 Useful information If you want to know the maximum measuring length and the resolution of the draw-wire encoder please refer to the order code. The stroke per turn is always 100 mm (3.937 ), the maximum number of turns is 10 for SFA-1000 and 20 for SFA-2000. EXAMPLE 1 SFA-1000-GA-8192-L1 Stroke per turn = 100 mm (3.937 ) Resolution per turn = 8,192 CPR Max. number of encoder revolutions = 4,096 Linear resolution = 0.012 mm = 12 µm Information per mm = 81.92 Max. number of turns = 10 Max. measuring length = 1,000 mm (39.37 ) Number of information = 81,920 Interface = SSI LSB Right Aligned, Gray code EXAMPLE 2 SFA-2000-BA-4000-M2 Stroke per turn = 100 mm (3.937 ) Resolution per turn = 4,000 CPR Max. number of encoder revolutions = 4,096 Linear resolution = 0.025 mm = 25 µm Information per mm = 40 Max. number of turns = 20 MAN SFA_1000_2000 SSI E 1.2 Mechanical installation 11 of 24

Max. measuring length = 2,000 mm (78.74 ) Number of information = 80,000 Interface = SSI LSB Right Aligned, Binary code 3.4 Maintenance The measuring system does not need any particular maintenance; anyway it has to be handled with the utmost care as any delicate electronic equipment. From time to time we recommend the following operations: the unit and the wire have to be cleaned regularly using a soft and clean cloth to remove dust, chips, moisture etc.; do not use oil to clean the wire. MAN SFA_1000_2000 SSI E 1.2 Mechanical installation 12 of 24

4 Electrical connection WARNING Electrical connection has to be carried out by qualified personnel only, with power supply disconnected and mechanical parts compulsorily in stop. 4.1 Cable and connectors connections Function M12 8-pin M8 cable 0Vdc 1 Black +10Vdc +30Vdc 2 Red Clock IN + 3 Yellow Clock IN - 4 Blue Data OUT + 5 Green Data OUT - 6 Orange Zero setting 7 White Counting direction 8 Grey Shielding Case Shield 4.2 M8 cable specifications Model Cross section Jacket : LIKA HI-FLEX sensor cable type M8 cable : 2 x 0.22 mm 2 + 6 x 0.14 mm 2 (24/26 AWG) : Matt Polyurethane (TPU) halogen free, oil, hydrolysis, abrasion resistant Shield : tinned copper braid, coverage 85% Outer diameter : 5.3 mm 5.6 mm (0.209 ± 0.220 ) Min. bending radius : Ø x 7.5 Work temperature Conductor resistance : -40 C +90 C (-40 F +194 F) dynamic installation -50 C +90 C (-58 F +194 F) - fixed installation : 90 /km / 148 /km MAN SFA_1000_2000 SSI E 1.2 Electrical connection 13 of 24

4.3 M12 8-pin connector specifications Male Frontal side A coding 4.4 Connection of the shield For signals transmission always use shielded cables. The cable shielding must be connected properly to the metal ring nut 3 of the connector in order to ensure a good earthing through the frame of the device. To do this disentangle and shorten the shielding 1 and then bend it over the part 2; finally place the ring nut 3 of the connector. Be sure that the shielding 1 is in tight contact with the ring nut 3. 4.5 Ground connection Minimize noise by connecting the shield and/or the connector housing and/or the frame to ground. Make sure that ground is not affected by noise. The connection point to ground can be situated both on the device side and on user s side. The best solution to minimize the interference must be carried out by MAN SFA_1000_2000 SSI E 1.2 Electrical connection 14 of 24

the user. You are advised to provide the ground connection as close as possible to the encoder. 4.6 Zero setting input The output value can be set to zero (reset) via an external signal issued by a PLC or other controller device. When the internal microprocessor receives the signal it resets the output information. This can be very useful for setting the zero position of both the encoder and the machine. To zero set the encoder, connect Zero setting input to +Vdc for 100 µs at least, then disconnect +Vdc; normally voltage must be at 0Vdc; zero set must be performed after Counting direction setting; we suggest performing the zero set when the encoder is in stop. Connect the Zero setting input to 0Vdc if not used. NOTE Please note that, after setting the zero point, the positive counting will be from 0 towards the max. value (see the table below); if you move the axis before the 0 point, the detected value will be the max. number of information 1 down. EXAMPLE Let's suppose we are using the SFA-2000-xx-8192-... model; the encoder is set to have the positive counting when pulling the cable out (see the Figure below). If you set the 0 along the path, starting from the 0 point, the output values will be from 0 towards the max. value (163,840, see the table below) when you pull out the cable; when the encoder moves back and cross the zero, the value immediately after 0 will be the max. number of information 1 (33,554,431).... 33554430 33554431 0 1 2... 163840 MAN SFA_1000_2000 SSI E 1.2 Electrical connection 15 of 24

Model Max. value SFA-1000-xx-8192-... 81,920 SFA-2000-xx-8192-... 163,840 SFA-1000-xx-4000-... 40,000 SFA-2000-xx-4000-... 80,000 SFA-1000-xx-2000-... 20,000 SFA-2000-xx-2000-... 40,000 SFA-1000-xx-1000-... 10,000 SFA-2000-xx-1000-... 20,000 Max. number of information 25 bits (33,554,432) 25 bits (33,554,432) 25 bits (33,554,432) 25 bits (33,554,432) 4.7 Counting direction input The counting direction circuit allows to reverse the counting direction. The standard counting direction (count up information) is to be intended when pulling the wire out. This input allows the count up when rewinding the wire. Connect the counting direction input to 0Vdc to have an increasing count when pulling the wire out; connect the counting direction input to +Vdc to have an increasing count when rewinding the wire. Connect the Counting direction input to 0Vdc if not used. WARNING After having set the new counting direction it is necessary to zero set the encoder position. Positive counting direction (count up information) when pulling the wire out MAN SFA_1000_2000 SSI E 1.2 Electrical connection 16 of 24

5 SSI interface Order code: SFA-xxxxx-BA- SFA-xxxxx-GA- 5.1 SSI (Synchronous Serial Interface) SSI (the acronym for Synchronous Serial Interface) is a synchronous point-to-point serial interface engineered for unidirectional data transmission between one Master and one Slave. Developed in the first eighties, it is based on the RS- 422 serial standard. Its most peculiar feature is that data transmission is achieved by synchronizing both the Master and the Slave devices to a common clock signal generated by the controller; in this way the output information is clocked out at each controller's request. Furthermore only two pairs of twisted wires are used for data and clock signals, thus a six-wire cable is required. The main advantages in comparison with parallel or asynchronous data transmissions are: less conductors are required for transmission; less electronic components; possibility of insulting the circuits galvanically by means of optocouplers; high data transmission frequency; hardware interface independent from the resolution of the absolute encoder. Furthermore the differential transmission increases the noise immunity and decreases the noise emissions. It allows multiplexing from several encoders, thus process controls are more reliable with simplified line design and easier data management. Data transmission is carried out as follows. At the first falling edge of the clock signal (1, the logic level changes from high to low) the absolute position value is stored while at the following rising edge (2) the transmission of data information begins starting from the MSB. MAN SFA_1000_2000 SSI E 1.2 SSI interface 17 of 24

At each change of the clock signal and at each subsequent rising edge (2) one bit is clocked out at a time, up to LSB, so completing the data word transmission. The cycle ends at the last rising edge of the clock signal (3). This means that up to n + 1 rising edges of the clock signals are required for each data word transmission (where n is the bit resolution); for instance, a 13-bit encoder needs 14 clock edges. If the number of clocks is greater than the number of bits of the data word, then the system will send a zero (low logic level signal) at each additional clock, zeros will either lead (LSB ALIGNED protocol) or follow (MSB ALIGNED protocol) or lead and/or follow (TREE FORMAT protocol) the data word. After the period Tm monoflop time, having a typical duration of 16 µsec, calculated from the end of the clock signal transmission, the encoder is then ready for the next transmission and therefore the data signal is switched high. The clock signal has a typical logic level of 5V, the same as the output signal which has customarily a logic level of 5V in compliance with RS-422 standard. The output code can be either Binary or Gray (see the order code). 5.2 LSB Right Aligned protocol LSB Right Aligned protocol allows to right align the bits, beginning from MSB (most significant bit) to LSB (least significant bit); LSB is then sent at the last clock cycle. If the number of clock signals is higher than the data bits, then unused bits are forced to logic level low (0) and lead the data word. This protocol can be used in encoders having any resolution. The word is 25-bit long, unused bits are set to 0 (zero). MAN SFA_1000_2000 SSI E 1.2 SSI interface 18 of 24

Thus it will be as follows: Model SFA-1000-xx-8192-... SFA-2000-xx-8192-... SFA-1000-xx-4000-... SFA-2000-xx-4000-... SFA-1000-xx-2000-... SFA-2000-xx-2000-... SFA-1000-xx-1000-... SFA-2000-xx-1000-... Counts per revolution Information per mm Resolution Length of the word 8,192 91.92 0.012 mm 25 bits 4,000 40 0.025 mm 25 bits 2,000 20 0.05 mm 25 bits 1,000 10 0.1 mm 25 bits Max. number of information 25 bits (33,554,432) 25 bits (33,554,432) 25 bits (33,554,432) 25 bits (33,554,432) The output code can be GRAY or BINARY (see the order code). The length of the measuring step is equal to the resolution. Structure of the transmitted position value: SFA-xxxxx-xx-xxxx bit 25 1 value MSB LSB WARNING Please note that the position value issued by the encoder is expressed in pulses; thus you have then to convert the number of pulses into a linear measuring unit. To convert the position value into millimetres (mm) or micrometres (µm) you have to multiply the number of information by the linear resolution of the encoder expressed in millimetres or micrometres. To know the linear resolution of the encoder please consider that the stroke per turn is 100 mm. The linear resolution results from the following calculation: Linear resolution = Stroke per turn Resolution CPR MAN SFA_1000_2000 SSI E 1.2 SSI interface 19 of 24

Then if you want to know the linear position value you will need to multiply the transmitted position value by the linear resolution. Linear position value = transmitted position * linear resolution NOTE Please note that the encoder's linear resolution can be read also in the order code next to the rotary resolution. Refer to the product datasheet. EXAMPLE 1 Let's suppose that we are using the SFA-1000-BA-1000-... draw-wire encoder. The resolution of the measuring device is 1,000 CPR (= 0.1 mm, see the order code in the product datatsheet). As stated, the linear resolution results from the following calculation: Linear resolution = Stroke per turn Resolution CPR Linear resolution = 100 1,000 = 0.1 mm = 1,000 µm Let's say that the transmitted position value is 123. Thus the linear position value will be as follows: Linear position value = transmitted position * linear resolution Linear position value = 123 * 0.1 = 12.3 mm = 12,300 µm EXAMPLE 2 Let's suppose that we are using the SFA-2000-GA-8192-... draw-wire encoder and the transmitted position value is 1569. The encoder resolution is 8192 CPR. The linear resolution (0.012 mm) can be read in the product datasheet; anyway it can be easily calculated as follows: Linear resolution = Stroke per turn Resolution CPR MAN SFA_1000_2000 SSI E 1.2 SSI interface 20 of 24

Linear resolution = 100 8,192 = 0.012 mm = 12 µm Thus the linear position value will be as follows: Linear position value = 1569 * 0.012 = 18.828 mm = 18,828 µm 5.3 Recommended transmission rates The SSI interface has a frequency of data transmission ranging between 100 khz and 300 khz. The CLOCK signals and the DATA signals comply with the EIA standard RS-422. The clock frequency (baud rate) depends on the length of the cable and must comply with the technical information reported in the following table: Cable length Baud rate < 50 m < 400 khz < 100 m < 300 khz < 200 m < 200 khz < 400 m < 100 khz The time interval between two Clock sequence transmissions must be at least 64 µs ( Tp = pause time > 64 µs). MAN SFA_1000_2000 SSI E 1.2 SSI interface 21 of 24

5.4 Max. speed and counting frequency To convert the speed value from m/s into rpm (revolutions per minute), then you must use the following formula: Speed in rpm = 60 * speed m/s 0.2 If you need to convert the speed value from rpm into m/s, use the following formula instead: Speed in m/s = ( rpm * 200 60 ) / 1000 EXAMPLE Let's assume that we are using the SFA-1000-BA-8192-... draw-wire encoder and the maximum speed of the application is 1 m/s. To calculate the counting frequency we must convert the speed expressed in m/s into rpm first. Using the above formula you will get: Speed in rpm = 60 * 1 0.2 = 300 rpm Please note that the maximum counting frequency of an encoder, expressed in khz, results from the number of revolutions per minute (rpm) -i.e. its rotational speed- and the number of pulses per revolution (PPR) -i.e. its resolution. It can be calculated by using the following formula: Maximum counting frequency (khz) = rpm * CPR 60 * 1000 It follows that the higher the maximum rotational speed of the encoder and its resolution, the higher the counting frequency. This has to be considered carefully when you program the encoder, in particular referring to the maximum counting frequency of the encoder as stated in the technical specifications, to the following electronic equipment and to the length of the cables. MAN SFA_1000_2000 SSI E 1.2 SSI interface 22 of 24

If you reverse the formula you can easily calculate the maximum number of revolutions starting from the value of the counting frequency (as allowed by the encoder, permitted by the subsequent electronics and accepted by the cable run) and the desired number of pulses per revolution: rpm = Maximum counting frequency (khz) * 60 * 1000 CPR The reversed formula can be very useful -for instance- when you know the maximum counting frequency that is applicable to the system (because of the encoder, the following electronics and the cable length) and you need to calculate the maximum rotational speed the encoder is allowed to reach at the desired resolution. 5.5 Recommended SSI circuit MAN SFA_1000_2000 SSI E 1.2 SSI interface 23 of 24

Document release Release date Description HW SW Installation file version 1.0 22.04.2015 First issue - - - 1.1 16.01.2017 General review, Italian and English versions separated - - - Lika Electronic Via S. Lorenzo, 25 36010 Carrè (VI) Italy Tel. +39 0445 806600 Fax +39 0445 806699 info@lika.biz www.lika.biz