DICOM Conformance Statement. Inturis Cardio View Station R 1.1. Document Number October 1999

Similar documents
DICOM Conformance Statement. CD-Medical Recorder for DCI systems CDM Release Document Number July 1998

DICOM Conformance Statement

DICOM. image protocol

DICOM Correction Item

DICOM Correction Proposal

ITU-T Y.4552/Y.2078 (02/2016) Application support models of the Internet of things

Tuesday, Dec 3rd 10:15 to 11:00 IHE Classroom at InfoRAD at RSNA 2002.

Request for Proposals

ITU-T Y Functional framework and capabilities of the Internet of things

Digital Imaging and Communications in Medicine (DICOM) Supplement 202: Real Real-Time Video

It s all about you. Mobile C-arm systems BV Endura

IHE. Display Consistency Test Plan for Image Displays HIMMS and RSNA. Integrating the Healthcare Enterprise

ATSC Standard: 3D-TV Terrestrial Broadcasting, Part 1

35PM-FCD-ST app-2e Sony Pictures Notes doc. Warning

Reference Parameters for Digital Terrestrial Television Transmissions in the United Kingdom

From Autonomous Subsystems to Integrated System

NOTICE. (Formulated under the cognizance of the CTA R4 Video Systems Committee.)

supermhl Specification: Experience Beyond Resolution

ENGINEERING COMMITTEE Energy Management Subcommittee SCTE STANDARD SCTE

Video System Characteristics of AVC in the ATSC Digital Television System

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

Proposed Standard Revision of ATSC Digital Television Standard Part 5 AC-3 Audio System Characteristics (A/53, Part 5:2007)

CAPTURE CAPTURE. VERSiON 1.2. Specialists in Medical. Digital Imaging Solutions

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK

ATSC Standard: Video Watermark Emission (A/335)

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

ANSI/SCTE

Quick reference guide

Subtitle Safe Crop Area SCA

This document is a preview generated by EVS

Module 8 VIDEO CODING STANDARDS. Version 2 ECE IIT, Kharagpur

MAP Optical Power Meter Module (mopm-b1)

ATSC Candidate Standard: Video Watermark Emission (A/335)

ITU-T Y Reference architecture for Internet of things network capability exposure

ITU-T Y Specific requirements and capabilities of the Internet of things for big data

Multi-Frame Matrix Capture Common File Format (MFMC- CFF) Requirements Capture

Network Operations Subcommittee SCTE STANDARD SCTE SCTE-HMS-QAM-MIB

SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS Infrastructure of audiovisual services Coding of moving video

medlab One Channel ECG OEM Module EG 01000

COLORSCAN. Technical and economical proposal for. DECOSYSTEM / OFF.A419.Rev00 1 of 8. DECOSYSTEM /OFF A419/09 Rev November 2009

AMERICAN NATIONAL STANDARD

ATSC Standard: A/342 Part 1, Audio Common Elements

IEEE 100BASE-T1 Physical Coding Sublayer Test Suite

SOUTH AFRICAN NATIONAL STANDARD

SDTV 1 DigitalSignal/Data - Serial Digital Interface

CARESTREAM DIRECTVIEW Elite CR System

Usage of any items from the University of Cumbria s institutional repository Insight must conform to the following fair usage guidelines.

CARESTREAM DIRECTVIEW Elite CR System

MISB ST STANDARD. Time Stamping and Metadata Transport in High Definition Uncompressed Motion Imagery. 27 February Scope.

Version 0.5 (9/7/2011 4:18:00 a9/p9 :: application v2.doc) Warning

PACS TOMO COMPATIBILITY

Next Generation Software Solution for Sound Engineering

Images and Formats. Dave Bancroft. Philips Broadcast Film Imaging

Product Information. EIB 700 Series External Interface Box

MTS/T-BERD Platforms WDMPMD Module

MX215. Your advantages. 2MP Medical-Display

INTERNATIONAL STANDARD

for File Format for Digital Moving- Picture Exchange (DPX)

Walter Graphtek's PL-EEG

Erratum Spec 1.0 Page Sections Affected Description. Trusted Environment. Reel n+1... Encryption. (Reel n) [optional] Encryption (Reel n) [optional]

CONSOLIDATED VERSION IEC Digital audio interface Part 3: Consumer applications. colour inside. Edition

RECOMMENDATION ITU-R BT Methodology for the subjective assessment of video quality in multimedia applications

INTERNATIONAL STANDARD

The Versatile and Powerful ACLxy. ACLxy

VIDEO 2D SCALER. User Guide. 10/2014 Capital Microelectronics, Inc. China

In PS 3.3, Section C RT Ion Beams Session Record Module, add the following attributes and make the changes indicated:

INTERNATIONAL STANDARD

Guidance for Quality Assurance of PACS Diagnostic Display Devices

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA

American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts

NOTICE. (Formulated under the cognizance of the CTA R4.8 DTV Interface Subcommittee.)

FIBRE CHANNEL CONSORTIUM

Display Quality Assurance: Considerations When Establishing a Display QA Program. Mike Silosky, M.S. 8/3/2017

ATSC Standard: 3D-TV Terrestrial Broadcasting, Part 5 Service Compatible 3D-TV using Main and Mobile Hybrid Delivery

INTERNATIONAL STANDARD

ATSC Digital Television Standard: Part 6 Enhanced AC-3 Audio System Characteristics

quantumdata TM G Video Generator Module for HDMI Testing Functional and Compliance Testing up to 600MHz

Calibration Best Practices

Instruction for Diverse Populations Multilingual Glossary Definitions

for Television ---- Formatting AES/EBU Audio and Auxiliary Data into Digital Video Ancillary Data Space

HDMI / Video Wall over IP Receiver with PoE

TGL2210-SM_EVB GHz 100 Watt VPIN Limiter. Product Overview. Key Features. Applications. Functional Block Diagram. Ordering Information

Integration of Simple LIMS with Mindray using Mirth Connect

OmniStream R-Type. Dual-Channel Networked AV Encoder. Introduction. Applications

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

OmniStream R-Type. Single-Channel Networked AV Decoder. Introduction. Applications

Acquisition Control System Design Requirement Document

Conformity assessment procedures for Radio & Telecommunication Terminal Equipment Scheme

)454 ( ! &!2 %.$ #!-%2! #/.42/, 02/4/#/, &/2 6)$%/#/.&%2%.#%3 53).' ( 42!.3-)33)/. /&./.4%,%0(/.% 3)'.!,3. )454 Recommendation (

SOUTH AFRICAN NATIONAL STANDARD

CONTROL VISIO 0033 (0) ASSISTANCE ACCESSORIES SUPERVISION WALL UNIT INTEGRATION. Direct line

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

Digital SWIR Scanning Laser Doppler Vibrometer

administration access control A security feature that determines who can edit the configuration settings for a given Transmitter.

Software Quick Manual

NOTICE. (Formulated under the cognizance of the CTA R4.8 DTV Interface Subcommittee.)

TECHNICAL MANUAL. Cheetah VIDEO MATRIX ROUTERS 3G VIDEO INPUT CARD WITH AUDIO DE-EMBEDDING AND 3G VIDEO OUTPUT CARD WITH AUDIO EMBEDDING

ENGINEERING COMMITTEE Digital Video Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Getting Started After Effects Files More Information. Global Modifications. Network IDs. Strand Opens. Bumpers. Promo End Pages.

FFDM Quality Control in Canada - a Vendor Neutral Approach

Transcription:

Philips Medical Systems DICOM Conformance Statement Inturis Cardio View Station R 1.1 Document Number 4522 982 71921 27 October 1999 Copyright Philips Medical Systems Nederland B.V. 1999 Philips Medical Systems apple PHILIPS

Page ii DICOM Conformance Statement 4522 982 71921-27 Oct 99 Issued by: Philips Medical Systems Nederland B.V. Integrated Clinical Solutions, Marketing & Communications Building QV-280 P.O. Box 10.000 5680 DA Best The Netherlands Tel.: +31 40 2762456 Fax.: +31 40 2762673 email: dicom@philips.com Internet (with the latest versions of Conformance Statements and other DICOM information): http://www.philips.com/ms/solution/connect ftp://ftp.philips.com/pub/ms/dicom/conformance_stmnts

9896 000 76921-27 Oct 99 DICOM Conformance Statement Page iii 1 Introduction............................................... 1 1.1 Scope and field of application............................... 1 1.2 Intended audience......................................... 1 1.3 Contents and structure..................................... 1 1.4 Used definitions, terms and abbreviations...................... 1 1.5 References.............................................. 1 1.6 Important note to the reader................................. 2 1.7 General Acronyms and Abbreviations......................... 3 2 Implementation model....................................... 4 2.1 Application Data Flow Diagram.............................. 4 2.2 Functional definition of Application Entities.................... 6 2.2.1 Application Entity: DICOM Reader........................ 6 2.3 Sequencing of Real World Activities.......................... 6 2.4 Implementation Identifying Information....................... 7 3 AE Specifications........................................... 8 3.1 AE Specification: DICOM Reader............................ 8 3.1.1 Application Entity Title.................................. 8 3.1.2 RWA Review and Analysis of X-ray Examination............. 8 3.1.3 RWA hardcopy........................................ 9 4 Extensions/Specializations/Privatizations....................... 10 4.1 Edge Enhancement Sequence................................ 10 5 Configuration.............................................. 11 6 Support of Extended Character Sets........................... 11 7 Specification of the applied IODs.............................. 12 7.1 Basic Cardiac Media Application Profile....................... 12 7.1.1 Applied XA and SC Image IOD........................... 12 7.1.2 Applied Basic Cardiac Directory IOD....................... 12 7.1.3 Applied Patient Management IOD.......................... 13 7.2 Applied SC Image IOD..................................... 13 8 Implementation restrictions and choices........................ 19

Page iv DICOM Conformance Statement 9896 000 76921-27 Oct 99

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 1 Introduction 1 Introduction This chapter provides general information about the purpose, scope and contents of this Conformance Statement. 1.1 Scope and field of application The scope of this DICOM Conformance Statement is to facilitate data exchange with equipment of Philips Medical Systems. This document specifies the compliance to the DICOM standard (formally called the NEMA PS 3.X-1996 standards). It contains a short description of the applications involved and provides technical information about the data exchange capabilities of the equipment. The main elements describing these capabilities are: the supported DICOM Service Object Pair (SOP) Classes, Roles, Information Object Definitions (IOD) and Transfer Syntaxes. The field of application is the integration of the Philips Medical Systems equipment into an environment of medical devices. This Conformance Statement should be read in conjunction with the DICOM standard and its addenda [DICOM]. The conformance to the DICOM standard is a key element of the Inturis Program (see [INTURIS]). 1.2 Intended audience This Conformance Statement is intended for: (potential) customers, system integrators of medical equipment, marketing staff interested in system functionality, software designers implementing DICOM interfaces. It is assumed that the reader is familiar with the DICOM standard. 1.3 Contents and structure The DICOM Conformance Statement is contained in chapter 2 through 7 and follows the contents and structuring requirements of DICOM PS 3.2-1996. 1.4 Used definitions, terms and abbreviations DICOM definitions, terms and abbreviations are used throughout this Conformance Statement. For a description of these, see NEMA PS 3.3-1996 and PS 3.4-1996. The word Philips in this document refers to Philips Medical Systems. 1.5 References [DICOM] The Digital Imaging and Communications in Medicine (DICOM) standard: NEMA PS 3.X 1996 National Electrical Manufacturers Association (NEMA) Publication Sales 1300 N. 17th Street, Suite 1847 Rosslyn, Va. 22209, United States of America [INTURIS] Inturis for Cardiology

Page 2 DICOM Conformance Statement 4522 982 71921-27 Oct 99 Introduction On-Line Image Access Doc. nr. 4522 982 69681 Philips Medical Systems Ned. BV 1.6 Important note to the reader This Conformance Statement by itself does not guarantee successful interoperability of Philips equipment with non-philips equipment. The user (or user s agent) should be aware of the following issues: Interoperability Interoperability refers to the ability of application functions, distributed over two or more systems, to work successfully together. The integration of medical devices into a networked environment may require application functions that are not specified within the scope of DICOM. Consequently, using only the information provided by this Conformance Statement does not guarantee interoperability of Philips equipment with non-philips equipment. It is the user s responsibility to analyse thoroughly the application requirements and to specify a solution that integrates Philips equipment with non-philips equipment. Validation Philips equipment has been carefully tested to assure that the actual implementation of the DICOM interface corresponds with this Conformance Statement. Where Philips equipment is linked to non-philips equipment, the first step is to compare the relevant Conformance Statements. If the Conformance Statements indicate that successful information exchange should be possible, additional validation tests will be necessary to ensure the functionality, performance, accuracy and stability of image and image related data. It is the responsibility of the user (or user s agent) to specify the appropriate test suite and to carry out the additional validation tests. New versions of the DICOM Standard The DICOM Standard will evolve in future to meet the user s growing requirements and to incorporate new features and technologies. Philips is actively involved in this evolution and plans to adapt its equipment to future versions of the DICOM Standard. In order to do so, Philips reserves the right to make changes to its products or to discontinue its delivery. The user should ensure that any non-philips provider linking to Philips equipment, also adapts to future versions of the DICOM Standard. If not, the incorporation of DICOM enhancements into Philips equipment may lead to loss of connectivity (in case of networking) and incompatibility (in case of media).

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 3 Introduction 1.7 General Acronyms and Abbreviations. The following acronyms and abbreviations are used in the document. ACC American College of Cardiology AE Application Entity ACR American College of Radiology ANSI American National Standard Institute BOT Basic Offset Table CD-R CD Recordable CD-M CD Medical CIVP Cardio Image Viewing Package DCI Digital Cardio Imaging DCR Dynamic Cardio Review DICOM Digital Imaging and Communication in Medicine DIMSE DICOM Message Service Element DIMSE-C DICOM Message Service Element-Composite DIMSE-N DICOM Message Service Element-Normalized ELE Explicit VR Little Endian EBE Explicit VR Big Endian FSC File Set Creator GUI Graphic User Interface HIS Hospital Information System HL7 Health Level Seven ILE Implicit VR Little Endian IOD Information Object Definition ISIS Information System - Imaging System NEMA National Electrical Manufacturers Association PDU Protocol Data Unit RIS Radiology Information System RWA Real World Activity SC Secondary Capture SCM Study Component Management SCP Service Class Provider SCU Service Class User SOP Service Object Pair TCP/IP Transmission Control Protocol/Internet protocol UID Unique Identifier WLM Worklist Management

Page 4 DICOM Conformance Statement 4522 982 71921-27 Oct 99 Implementation model 2 Implementation model The Implementation Model identifies all of the DICOM Application Entities (AEs) and relates these Application Entities to the Real World Activities (RWAs). The DICOM interface for the CD-Medical product range of Philips Medical Systems is a Media Storage implementation of the 120mm Compact Disc Recordable (CD-R) medium, as described in the NEMA standard PS3.12-Annex F. 2.1 Application Data Flow Diagram The Philips Inturis Cardio Image Viewing Package (Philips Inturis CIVP) application domain can be represented by a single Application Entity, describing the reading process (see Figure 2-2 on page 6). The Philips Inturis CIVP will be the PC-NT based counterpart of the current CD-Medical Viewer. In addition to the CD-Medical viewer, it shall offer the following functionality: Local Archive for multiple patients. Point to Point printer Enhanced zoom and loupe. Adapted video mode for video copies On-line help for all functions Export current frame to other applications

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 5 Implementation model Figure 2-1: Topology Image The DICOM Reader AE provides Standard Conformance to the DICOM Media Storage Service and File Format Class (PS 3.10) and the Media Storage Application Profile (PS 3.11). And Standard Conformance to the SC IOD The CD-Medical DICOM Reader AE is able to read the multi-frame images stored in twotypes of data-streams on the CD-R media. The first stream type is according to the DICOM format of the ACC-ACR-NEMA; i.e. each (cardiac) frame is stored as a 512 x 512, 8 bit deep, pixel matrix using a lossless JPEG com-

Page 6 DICOM Conformance Statement 4522 982 71921-27 Oct 99 Implementation model pression algorithm; i.e. with a compression factor of about 2. The second stream support the SC Image IOD.. Review and Analysis of X-Ray Examination data Hardcopy DICOM Reader FSR CD-R Figure 2-2: Application Data Flow diagram of the Philips Inturis CIVP 2.2 Functional definition of Application Entities Referring to Figure 2-1, the local RWA Review of X-Ray Examination (i.e. putting a CD-R disc into the Philips Inturis CIVP) will cause the AE DICOM Reader to read the File-set on the CD-R medium. The term File-set Reader (FSR) means that the Philips Inturis CIVP device will read the DICOMDIR file and one or more DICOM files, covering all X-ray images, patient data, study parameters, etc. 2.2.1 Application Entity: DICOM Reader The AE DICOM Reader supports the following functions; Read the DICOMDIR file that represents the contents of the (image) data as recorded. This information is displayed as an ordered list of icon images together with pertinent identifying information (patient name, etc.). Read the selected image SOP (Service Object Pair) instance from CD-R device and/or local archive and display it on the monitor of the Philips Inturis CIVP. This information is displayed as an ordered list of frames of the selected image or as a dynamic review of the selected image. The Philips Inturis CIVP application shall not provide functions yet to create patient folders into the local archive manually. Patient folders are only created from data that have been imported from local CD into the local archive. In this release the relation patient vs. procedure is considered 1:1. Multiple procedures are not married up into one patient folder. 2.3 Sequencing of Real World Activities The Reader process is activated by request from the user. In case of multiple discs for a single examination, these discs are considered as self-contained. Multiple CD s which originate from one image-transmission digital cat-lab -> CD -medical Recorder (this means with a Disc.inf on the CD s to recognize multiple CD s) are married up to one patient/procedure folder in the local archive.

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 7 Implementation model Multiple CD s which originate from two or more image-transmissions digital cath-lab -> CD- Medical recorder can not be handled in this release. 2.4 Implementation Identifying Information The Implementation Class UID is: Implementation Class UID = 1.3.46.670589.7.7.1.1 The Implementation Version Name is not relevant because this release of the Philips Inturis CIVP only reads CD-R Media and has no network capabilities.

Page 8 DICOM Conformance Statement 4522 982 71921-27 Oct 99 AE Specifications 3 AE Specifications This chapter describes in more detail the DICOM context of each individual Application Entity. Since the Philips Inturis CIVP encompasses a single Application Entity, only one section is necessary to describe the AE specification. 3.1 AE Specification: DICOM Reader The DICOM Reader AE provides Standard Conformance to the DICOM Media Storage Service and File Format Class (PS 3.10) and the Media Storage Application Profile (PS 3.11) as far as the reading of lossless compressed images is concerned. Table 3-1: Application Profile, Activities and Roles of the CD-Medical DICOM Reader Application Profile Identifier Real World Activity Role SC Option Basic Cardiac Media Application STD-XABC-CD Review of X-ray Examination. Profile (1) SC Image Storage (2) STD-???? review of Secondary capture Examination FSR FSR Interchange. Interchange (1) The application profile only accepts 8 bit deep pixel depth. (2) This application profile also supports the 1024*1024 SC Image IOD, with the exception that it can also read a 1280*1024 pixel matrix which are generated by Cardio applications. 3.1.1 Application Entity Title The Application Entity Title is not relevant because this release of the Philips Inturis CIVP only reads CD-R Media and has no network capabilities. 3.1.2 RWA Review and Analysis of X-ray Examination The DICOM Reader AE will act as a FSR using the Interchange option when reading the directory of the medium and when reading the requested images. 3.1.2.1 Application Profile(s) for this RWA Refer to Table 3-1 for the list of Application Profiles that invoke this AE. 3.1.2.2 Required and optionally applied Attributes and DICOMDIR Keys The Modules and Attributes needed for the correct review of lossless compressed images (Basic Cardiac Media Application Profile) are specified in detail in section 7.1 on page 12. These Modules and Attributes are Mandatory (type 1 or 2) in the DICOM 3.0 standard. The optionally applied Modules and Attributes (if present on the disc) are also specified in that section. The Keys needed for the correct review of the contents of a CD-R disc are specified in detail in section 7.1 on page 12. These Keys are Mandatory (type 1 or 2) in the DICOM 3.0 standard. The optionally applied Keys (if present on the disc) are also specified in that section.

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 9 AE Specifications 3.1.3 RWA hardcopy The DICOM Reader AE will act as a FSR using the Interchange option when the operator requests for a hardcopy of (a selected part of) the information on CD-R. 3.1.3.1 Application Profile(s) for this RWA Refer to Table 3-1 for the list of Application Profiles that invoke this AE. 3.1.3.2 Required and optionally applied Attributes and DICOMDIR Keys See section 3.1.2.2 on page 8. Attribute Institution Name and Hospital Name on the CD-R disc (if present) are printed on the Hardcopy.

Page 10 DICOM Conformance Statement 4522 982 71921-27 Oct 99 Extensions/Specializations/Privatizations 4 Extensions/Specializations/Privatizations The Standard Extended Attributes (if present on the CD-R disc) applied by Philips Inturis CIVP for the review applications are specified in the sections below. Due to these extensions, the Philips Inturis CIVP will recognise private attributes identified with Private Creator string CARDIO-D.R. 1.0. 4.1 Edge Enhancement Sequence Each frame within a lossless compressed image may be Edge Enhanced by applying the formula and the values specified in the Edge Enhancement Sequence (see Table 4-1). Whether the Edge Enhancement is performed or not, depends on the values of the Edge Enhancement Attributes. Table 4-1 : Edge Enhancement Sequence Attribute Name Tag Type Attribute Description Edge Enhancement Sequence (0029,xx00) 3 Edge Enhancement Sequence describing the Edge Enhancement Filter to be applied to the image. Formula: E=F+((F-C)*G) E: Pixel value of enhanced frame F: pixel value of source frame C: pixel value of convoluted region G: edge enhancement gain > Convolution Kernel Size (0029,xx01) 1C Number of rows and columns in the convolution kernel. The first value specifies the number of rows; the second value specifies the number of columns. Values shall be equal or greater than 3. Required if Edge Enhancement Sequence (0029,xx00) is present. A fixed kernel size of 5 x 5 is applied; kernel sizes other than 5 x 5 are ignored. > Convolution Kernel Coefficients (0029,xx02) 1C The coefficients of the convolution kernel organized by row from left to right starting with the top row. The number of values shall be equal to the number of rows times the number of columns specified in the Convolution Kernel Size. Required if Edge Enhancement Sequence (0029,xx00) is present. The Philips Inturis CIVP supports only coefficients of 1; other coefficients are ignored. > Edge Enhancement Gain (0029,xx03) 1C Edge Enhancement Gain to be used. Required if Edge Enhancement Sequence (0029,xx00) is present. The Philips Inturis CIVP supports a gain between 0 and 12.4. If another gain is specified, the Edge Enhancement Gain 0 is taken.

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 11 Configuration 5 Configuration not applicable. 6 Support of Extended Character Sets The Philips Inturis CIVP supports the following Extended Character Set(s) on the medium: ISO_IR 100: Latin Alphabet No. 1

Page 12 DICOM Conformance Statement 4522 982 71921-27 Oct 99 Specification of the applied IODs 7 Specification of the applied IODs The Attributes required or applied (if present on the disc) by the review functions of the Philips Inturis CIVP are specified in detail for the Basic Cardiac Media Application Profile. 7.1 Basic Cardiac Media Application Profile 7.1.1 Applied XA and SC Image IOD The Attributes that are required by the review functions of the Philips Inturis CIVP are specified for the SOP Classes in this Application Profile in Table 7-1. i Table 7-1: Required Attributes in the standard XA Image IOD Required Module Reference Comments a Transfer Syntax UID 0002:0010 for lossless compression Image Type 0008:0008 - Instance Creation Date 0008:0012 - Patient s Name 0010:0010 - Frame Time 0018:1063 - Samples per Pixel 0028:0002 - Photometric Interpretation 0028:0004 - Planar Configuration 0028:0006 - Rows 0028:0010 - Columns 0028:0011 - a. All the not mentioned attributes are optional and will be read but are not required for the viewing functionality. 7.1.2 Applied Basic Cardiac Directory IOD Table 7-2 specifies the Attributes/Keys in the Basic Cardiac Directory IOD required by the review functions of the Philips Inturis CIVP. Table 7-2: The Review and Archive parameters in the DICOMDIR File Applied optional Module Review Archive Patient - Patient ID, Patient Name, Patient Birth Date, Study - Study ID, Study Date, Study Time

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 13 Specification of the applied IODs Applied optional Module Review Archive Series - Series Number Image Referenced File ID Image Number Icon Rows, Columns 7.1.3 Applied Patient Management IOD None of the Modules (so none of the Attributes) in the Detached Patient Management IOD are required by the review functions of the Philips Inturis CIVP. 7.2 Applied SC Image IOD. This paragraph will provide an overview of all the used attributes in the SC Image IOD. Table 7-3: Applied Modules in the SC Image IOD Module Usage Reference SOP Common M Table 7-4 Patient M Table 7-5 General Study M Table 7-6 General Series M Table 7-7 General Equipment U Table 7-8 SC Equipment M Table 7-9 General Image M Table 7-10 Image Pixel M Table 7-11 Modality LUT U Table 7-12 VOI LUT U Table 7-13 Table 7-4: SC Image Storage SOP Class - SOP Common Module Specific Character Set (0008,0005) Character Set that expands or replaces the Basic Graphic Set. Defined terms: ISO_IR 100: Latin alphabet No. 1, supplementary set. Required if an extended or replacement character set is used.

Page 14 DICOM Conformance Statement 4522 982 71921-27 Oct 99 Specification of the applied IODs Table 7-4: SC Image Storage SOP Class - (Continued)SOP Common Module Instance Creation Date (0008,0012) Date the SOP Instance was created. Instance Creation Time (0008,0013) Time the SOP Instance was created. Instance Creator UID (0008,0014) Uniquely identifies the device which created the SOP Instance. SOP Class UID (0008,0016) 1.2.840.10008.5.1.4.1.1.7 SOP Instance UID (0008,0018) Uniquely identifies the SOP Instance. Table 7-5: SC Image Storage SOP Class - Patient Module Referenced Patient Sequence (0008,1120) A sequence which provides reference to a Patient SOP Class/Instance pair. Only a single reference is allowed. >Referenced SOP Class UID (0008,1150) Uniquely identifies the referenced SOP Class. Required if Referenced Patient Sequence (0008,1120) is sent. >Referenced SOP Instance UID (0008,1155) Uniquely identifies the referenced SOP Instance. Required if Referenced Patient Sequence (0008,1120) is sent. Patient s Name (0010,0010) Patient s full legal name. Patient ID (0010,0020) Primary hospital identification number or code for the patient. Patient s Birth Date (0010,0030) Birth date of the patient. Patient s Sex (0010,0040) Sex of the named patient. Enumerated Values: M: Male. F: Female. O: Other.

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 15 Specification of the applied IODs Table 7-6: SC Image Storage SOP Class - General Study Module Study Date (0008,0020) Date the Study started. Study Time (0008,0030) Time the Study started. Accession Number (0008,0050) A RIS generated number which identifies the order for the Study. Referring Physicians Name (0008,0090) Patient s referring physician. Study Description (0008,1030) Institution-generated description or classification of the Study component performed. Referenced Study Sequence (0008,1110) A sequence which provides reference to a Study SOP Class/Instance pair. Only a single reference is allowed. >Referenced SOP Class UID (0008,1150) Uniquely identifies the referenced SOP Class. Required if Referenced Study Sequence (0008,1110) is sent. >Referenced SOP Instance UID (0008,1155) Uniquely identifies the referenced SOP Instance. Required if Referenced Study Sequence (0008,1110) is sent. Study Instance UID (0020,000D) Unique identifier for the Study. Study ID (0020,0010) User or equipment generated Study identifier. Table 7-7: SC Image Storage SOP Class -General Series Module Series Date (0008,0021) Date the Series started. Series Time (0008,0031) Time the Series started. Modality (0008,0060) XA Performing Physicians Name (0008,1050) Name of the physicians administering the Series. Referenced Study Component Sequence (0008,1111) Uniquely identifies the Study Component SOP Instances to which the Series is related. >Referenced SOP Class UID (0008,1150) Uniquely identifies the referenced SOP Class. Required if Referenced Study Component Sequence (0008,1111) is sent. >Referenced SOP Instance UID (0008,1155) Uniquely identifies the referenced SOP Instance. Required if Referenced Study Component Sequence (0008,1111) is sent.

Page 16 DICOM Conformance Statement 4522 982 71921-27 Oct 99 Specification of the applied IODs Table 7-7: SC Image Storage SOP Class -General Series Module Series Instance UID (0020,000E) Unique identifier of the Series. Series Number (0020,0011) A number that identifies this Series. Table 7-8: SC Image Storage SOP Class - General Equipment Module Manufacturer (0008,0070) Manufacturer of the equipment that produced the digital images. Institution Name (0008,0080) Institution where the equipment is located that produced the digital images. Manufacturer s Model Name (0008,1090) Manufacturer s model number of the equipment that produced the digital images. Software Versions (0018,1020) Manufacturer s designation of software version of the equipment that produced the digital images. Table 7-9: SC Image Storage SOP Class - SC Equipment Module Conversion Type (0008,0064) WSD Table 7-10: SC Image Storage SOP Class -General Image Module Image Number (0020,0013) A number that identifies this Image. Patient Orientation (0020,0020) Patient direction of the rows and columns of the Image. Image Comments (0020,4000) User-defined comments about the Image.

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 17 Specification of the applied IODs Table 7-11: SC Image Storage SOP Class - Image Pixel Module Samples per Pixel (0028,0002) 1 Photometric Interpretation (0028,0004) MONOCHROME2 Rows (0028,0010) Number of rows in the image. Columns (0028,0011) Number of columns in the image. Pixel Aspect Ratio (0028,0034) Ratio of the real world spacing of the pixels in the Image, specified by a numeric pair: row value (delimiter) column value. Required if the aspect ratio is not 1\1. Bits Allocated (0028,0100) 8 Bits Stored (0028,0101) 8 High Bit (0028,0102) 7 Pixel Representation (0028,0103) 0000H (unsigned integer) Pixel Data (7FE0,0010) A data stream of the pixel samples which comprise the Image. Table 7-12: SC Image Storage SOP Class - Modality LUT Module Modality LUT Sequence (0028,3000) Defines as sequence of Modality LUTs. >LUT Descriptor (0028,3002) Specifies the format of the LUT Data in this Sequence. Required if the Modality LUT Sequence (0028,3000) is sent.

Page 18 DICOM Conformance Statement 4522 982 71921-27 Oct 99 Specification of the applied IODs Table 7-12: SC Image Storage SOP Class - Modality LUT Module >Modality LUT Type (0028,3004) Specifies the output values of this Modality LUT. Defined Terms: OD: The number in the LUT represents thousandths of optical density. That is, a value of 2140 represents an optical density of 2.140. US: Unspecified. Other values are permitted but not defined by DICOM. Required if the Modality LUT Sequence (0028,3000) is sent. >LUT Data (0028,3006) LUT Data in this Sequence. Required if the Modality LUT Sequence (0028,3000) is sent. Table 7-13: SC Image Storage SOP Class -VOI LUT Module Window Center (0028,1050) Window Center for display. Window Width (0028,1051) Window Width for display. Required if Window Center (0028,1050) is sent.

4522 982 71921-27 Oct 99 DICOM Conformance Statement Page 19 Implementation restrictions and choices 8 Implementation restrictions and choices A number of implementation restrictions/choices exist in this release of the Philips Inturis CIVP which may limit the use of the review functions: Multi Patient /Multi Study is supported. No restriction in max. no. of images No restriction in max. no. of frames, however is no. of frames exceeds PCs memory, playbackspeed may reduce dramatically. Edge Enhancement reacts only on the gain factor, see also Table 4-1 on page 10. The ECG data is displayed (if present) as far as image frames are present. The ISO 9660 file naming is less strictly implemented; file names without. and ;1 at the end of the name are accepted. A negative Window Width is not supported. Edge-enhancements, Zoom, Loupe and presentation of ECG curve may limit the display speed. Multiframe Images without basic offset table can not be displayed. The contents of a Detached Patient Management file do not overrule the Patient Demographics DICOMDIR and Image files.