Quick-disconnect cables. Adjustable mounting brackets

Similar documents
Quick-disconnect cables. Adjustable mounting brackets

Quick-disconnect cables. Adjustable mounting brackets

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

MiniSafe Light Curtains

Safety Light Curtains GuardShield

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

Specifications. Response Time. Status Indicators. Scanning Range/Resolution. Vibration. Shock. Physical Characteristics.

2-12. General Principles 2-Opto-electronics Safety Switches Operator. Interface. Logic Power

Allen-Bradley Automation

Safety Light Curtains

POC Type 4 GuardShield Standard, Remote Teach & Cascadable Safety Light Curtains

Model Number Structure

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance

Safety Light Curtain Orion1 Extended

Photoelectric Sensors E3F2

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

SQM40/41 Actuators for air and gas dampers

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

MiniSafe Light Curtains

MegaSafe MG4600 MG4600. safety light curtains. Description

...Simple IT WORKS WHY MERLIN 3000 FOR PRESS BRAKES? SIMPLE... Merlin 3000 was designed specifically for press brakes.

User Manual. SafeShield Safety Light Curtain Hardware

Safety Light Curtain C 4000 Basic/Micro

LD OEM/LD PDS/LD PeCo

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

Safety Light Curtain C 4000

F3SG-RA. Safety Light Curtain. Advanced Safety Light Curtain in Rugged, IP67 Rated Housing. Online. Blanking

Requirements You Must Meet When Installing and Using Shadow Safety Light Curtains

02/11/2015

OM2000N INSTALLATION MANUAL

Shadow VI. Tech Support Hotline EST. Safety Light Curtain Rev. E July

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Type Contact form Model

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Ordering details. Approval. Classification

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Safety Light Curtain C 4000

Part-Turn Electric Multi-Turn Electric

Pauluhn Apex. Linear, high bay LED luminaires designed for harsh & heavy industrial applications

Safety Light Curtain Type4 SIL3 PLe

EZ-SCREEN. Type 4 Point-of-Operation V-Series No configuration necessary; preconfigured for Trip Output, Scan Code 1, MACHINE SAFETY

I/A Series Hardware Fiber Optic LAN Converter

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

Wall-/Pipe-Mount Level Indicator

Datasheet - SRB-E-201ST

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Photoelectrics Through-beam Type PA18C.T..., DC

High performance circuit breakers

XR47-24 Models 24 W/ F (43 W/ C)

Operating Instructions

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Series CT7N Bimetallic Overload Relays

SF2 Series Instruction Manual INDEX

Datasheet - SRB301LC 24VAC/DC

OPERATING INSTRUCTIONS. detec2 Core Safety light curtain

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

SU17 Series Fiber Optic Sensors

Actuators IC 20, IC 40

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Safety Light Curtains

Multifunction Digital Timer

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

Inductive sensor BI1.5-EG08K-Y1

DISTRIBUTION AMPLIFIER

WCHE BTU/Hr Watts

Operating instructions Safety light curtain SLC440. Version 2.0. Content. 1. About this document

VGA to DVI Extender over Fiber SET

Amplifier for fiber optics. Dimensioned drawing

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

KVANT. Spectrum 1,6W RGB laser system. Product datasheet

Power Injector 1520 Series

XR47-24 Models 24 W/ F (43 W/ C)

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C)

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

XR47-24 Models 24 W/ F (43 W/ C)

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

WCHE BTU/Hr Watts

Cylindrical Photoelectric Sensor CY-100 SERIES

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

FOLLOW THE INSTRUCTIONS GIVEN IN THIS MANUAL CAREFULLY. FAILURE TO DO SO MAY CAUSE CUSTOMER COMPLAINTS AND SERIOUS CALLBACKS.

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

MHB BTU/Hr Watt

Inductive sensor NI3-EG08K-Y1-H1341

Colour Explosion Proof Video Camera USER MANUAL VID-C

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Inductive sensor NI10-M18-Y1X-H1141

Transcription:

OptoFence OF4100 File No. L90200 Description OptoFence OF4100 An OptoFence OF4100 system consists of an identical length transmitter and receiver combined with an STI Universal or DuoSafe controller and appropriate interconnecting cables. STI s patented Individual Beam Indicator lights make long-range alignment easier. The OptoFence is well suited for guarding large perimeters. Applicable Controllers OptoFence OF4100 transmitters and receivers can be used with the Universal controller or combined with other STI safety light curtain components and a DuoSafe controller as part of a system to guard more than one opening or machine. See controller sections for complete details. 2.0 inch (51 mm) resolution 100 foot (30.5 m) range Protected heights from 12 to 96 inches (305 to 2438 mm) Individual Beam Indicator lights; design concept covered by U.S. and international patents Quick-disconnect cables Adjustable mounting brackets Highly immune to electromagnetic interference, strobe or ambient light interference and welding flash Versions available for darkroom applications consult factory Status Indicator lights Go to the ngineering Guide C72

OptoFence OF4100 Applications Welding obot The OptoFence is ideal for establishing a safe perimeter around a welding robot. The OptoFence is immune to welding flash, has a 100-foot (30.5 m) range and can detect objects as small as 2.0 inches (51 m) in diameter. For the Latest Information Try Our Fax Back System at 1/916/431-6544 On the Internet: www.sti.com -mail: sales@sti.com C73

OptoFence OF4100 Specifications for Transmitter and eceiver Performance Protected Height: 12 to 96 inches (305 to 2438 mm) in 12 inch (305 mm) increments Operating ange: 1 to 100 feet (0.30 to 30.5 m) esolution: 2 inch (51 mm) Use of xact Channel Select and/or Floating Blanking may increase this value. ffective Aperture Angle: ±3 transmitter and receiver Light Source: 880 nm LD Light Source Life: 100,000 hours Indicators: Beam blocked, beam clear, interlock, individual beam Mechanical nclosure: Polyurethane powder-painted aluminum Cable Length: Transmitter 15 feet (4.6 m) standard, 100 foot (30.5 m) maximum; 30 foot (9.1 m) standard with DIN-style controller eceiver 5 feet (1.5 m) standard, 50 foot (15.2 m) maximum; 30 foot (9.1 m) standard with DIN-style controller Cable Connections: Circular, weather-tight disconnects nvironmental Protection ating: NMA 4, 12; IP65 Operating Temperature: 32 to 131 F (0 to 55 C) elative Humidity: 95% maximum, non-condensing Vibration: Tested in accordance with UL991 vibration specification, Section 20, at 5G peak vibration level, frequency range 5 60 Hz in 3 axes Shock: Tested to withstand shock resulting from a 3 foot-pound impact detailed in UL991, Section 21 Conformity/Approvals (when combined with an STI Universal or DuoSafe controller) Conforming to Standards: ANSI/IA 15.06-1992, ANSI B11.19-1990, OSHA 1910.217(c), OSHA 1910.212 Other Approvals: CSA Certified (file no. L90200) Specifications are subject to change without notice. For specifications on the Universal C controller, see page C104 For specifications on the DuoSafe controller, see page C94 Go to the ngineering Guide C74

OptoFence OF4100 Dimensions (inches/mm) (MTG) 2.05 52.1 4.35 110.5 1.27 32.1 1.82 46.1 1.00 25.5 4.58 116.2 1.25 31.8 2.00 50.8.58 14.6 B (MTG) (SLOT CNT- TO-CNT) A (SNSING FILD) OptoFence OF4100 Series 3.65 92.7 C.80.28 X DIA 20.3 7.0 SLOTS (4) This drawing is available in CAD format at www.sti.com/curtains/of4100/ For dimensions on the Universal C controller, see page C104 1.50 38.0 FONT VIW 2.01 51.1.55 14.0 2.56 65.1 4.56 115.7 MIN.30 DIA. 7.6 1.35 O.D. 34.3 C L SID VIW 2.40 C L 61.0 1.64 41.5 For dimensions on the DuoSafe controller, see page C94 OptoFence OF4100 Dimensions DIM OF4112 OF4124 OF4136 OF4148 OF4160 OF4172 OF4184 OF4196 A in./mm 12/305 24/610 36/914 48/1219 60/1524 72/1829 84/2134 96/2438 B in./mm 15.28/388 27.28/693 39.28/998 51.28/1303 63.28/1607 75.28/1912 87.28/2217 99.28/2522 C in./mm 16.38/416 28.38/721 40.38/1026 52.38/1330 64.38/1635 76.38/1940 88.38/2245 100.38/2550 System Shipping Weight lb./kg 25/11.3 30/13.6 33/15 38/17.2 39/17.7 48/21.8 52/23.6 56/25.4 For the Latest Information Try Our Fax Back System at 1/916/431-6544 On the Internet: www.sti.com -mail: sales@sti.com C75

OptoFence OF4100 Ordering To order an OptoFence OF4100 system with a Universal Controller, simply fill in the fields in the model number sequence given below. ach field is numbered and information on completing a specific field can be found in the sections which follow. Information is required in all fields. OF41 - X- ❶ ❷ ❸ ❸ xample: OF4124C-AC1-50X-15 This system has a 24 inch (610 mm) coverage height, 115 VAC input power, 50-foot (15.2 m) transmitter cable and a 15-foot (4.6 m) receiver. ❶ epresents the coverage height of the light curtain in inches. Designators are described below: Designator Coverage Height 12 12 inches (305 mm) 24 24 inches (610 mm) 36 36 inches (914 mm) 48 48 inches (1219 mm) 60 60 inches (1524 mm) 72 72 inches (1829 mm) 84 84 inches (2134 mm) 96 96 inches (2438 mm) For specifications and dimensions on the Universal C controller, see page C104 For information on STI safety light curtain accessories, see page C122 ❷ epresents Controller Style and Power Input. Designator C-AC1 C-AC2 C-DC1 C-DC2 C-DN-DC2 To order an OptoFence OF4100 as part of a DuoSafe system, see page C94 Description NMA 13 enclosure, 115 VAC NMA 13 enclosure, 230 VAC NMA 13 enclosure, 24 VDC negative ground NMA 13 enclosure, 24 VDC positive or negative ground DIN mount enclosure, 24 VDC positive or negative ground ❸ epresents transmitter (X) and receiver () cable length. The standard cable lengths supplied with a NMA 13 enclosure controller are a 15 foot (4.6 meter) transmitter and a 5 foot (1.5 meter) receiver. Cables are available in 5-foot increments from 5 to 100 feet (1.5 to 30.5 meters) for the transmitter and receiver. 5 to 50 feet (1.5 to 15.2 meters) for the receiver. The standard cable lengths supplied with a DIN mount enclosure controller are 30 feet (9.1 meters) on both the transmitter and receiver. Longer cables are available. For NMA13 enclosure: Designator Description 05 5 foot (1.5 meter) cable 10 10 foot (3.0 meter) cable 15 15 foot (4.6 meter) cable 20 20 foot (6.1 meter) cable 25 25 foot (7.6 meter) cable 30 30 foot (9.1 meter) cable 35 35 foot (10.7 meter) cable 40 40 foot (12.2 meter) cable 45 45 foot (13.7 meter) cable 50 50 foot (15.2 meter) cable 55 55 foot (16.8 meter) cable 60 60 foot (18.3 meter) cable 65 65 foot (19.8 meter) cable 70 70 foot (21.3 meter) cable 75 75 foot (22.9 meter) cable 80 80 foot (24.4 meter) cable 85 85 foot (25.9 meter) cable 90 90 foot (27.4 meter) cable 95 95 foot (29.0 meter) cable 100 100 foot (30.5 meter) cable For DIN-mount enclosure: Designator Description 30 30 foot (9.1 meter) cable 75 75 foot (22.9 meter) cable 100 100 foot (30.5 meter) cable Go to the ngineering Guide C76

OptoFence OF4100 Safety Standards and Precautions The OptoFence meets ANSI/IA 15.06-1992, ANSI B11.19-1990 and the following applicable OSHA standards. When used with mechanical power presses, OSHA standard 1910.217(c) applies. For other applications, the guarding requirements of section 1910.212 apply. When combined with an STI Universal or DuoSafe Controller, the OptoFence meets B11.19-1990 standards, including control reliability requirements for presence sensing devices, and complies with CSA and UL508 standards. Due to the wide beam spacing and corresponding large minimum object resolution, the OptoFence is best suited for perimeter guarding or applications where it can be installed farther away from the point of operation than a light curtain with a smaller object resolution. Information on the calculation of the safe mounting distance is included in the Installation and Operation Manual. Only use the OptoFence on machinery that stops consistently and immediately anywhere in its cycle or stroke. Never use an OptoFence on a full-revolution clutched press or machine. Access to the point of operation or hazardous machine area not protected by the OptoFence must be guarded by fencing, barriers or other appropriate methods. The purchaser, installer and employer are responsible for meeting all local, state and federal government laws, rules, codes or regulations relating to the proper use, installation, operation and maintenance of this control and the guarded machine. See Installation and Operation Manual for additional information. All application examples described are for illustration purposes only. Actual installations will differ from those indicated. Perimeter Guarding Special equirements For perimeter guarding installations, the guarded machine or robot controller must be wired so that any stop signal generated by the light curtain will cause an immediate stop of the hazardous motion. The machine or robot must only be restarted by actuation of a manual reset switch. This reset switch must be located outside the area of hazardous motion and positioned so that the hazardous area can be observed by the switch operator. This is intended to prevent a machine from automatically restarting once an obstruction is no longer detected by the sensing field of the light curtain. For the Latest Information Try Our Fax Back System at 1/916/431-6544 On the Internet: www.sti.com -mail: sales@sti.com C77

Custom Modifications Custom Modifications For Safety Light Curtains Custom Modifications STI offers a wide range of safety light curtains. The correct curtain for your application is probably in this engineering guide. If it isn't, contact our engineers to discuss your requirements. STI has an established reputation for creating custom modifications of standard products. Some examples are highlighted below. SD-safe Modification Versions of several STI safety light curtains are available for use in areas where it is important to dramatically reduce electrostatic discharge. The curtains have been tested to the standards of the OS/SD associations. Triboelectrification and static charge are well within the required limits. Consult STI for test results. High Temperature Fiber Optic Light Curtain STI can modify our standard MiniSafe MS4400 safety light curtain so that each individual beam is presented by a fiber optic cable. This allows the transmitter and receiver electronics to remain safely out of the high temperature area. Controller Quick-disconnect Certain applications call for to have double-ended quick-disconnect cables. This custom modification is available from STI. Quickdisconnect cables are available for transmitter, receiver, input power and relay output connections. MiniSafe Quick-disconnect Cables Transmitter LD Indicators eceiver MiniSafe Film-safe Safety Light Curtains When used in a photographic film production facility, the infrared light normally emitted by will fog the film and spoil production. STI has designed with no visible indicators and "film friendly" infrared light. Go to the ngineering Guide C130