POWER MONITORS ENERIUM RANGE. Minimize your energy consumption and optimize your installation

Similar documents
IQ Analyzer 6400/6600 Series. Cutler-Hammer Power Management Products High End Metering Capabilities

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

SAPLING WIRED SYSTEM

Sapling Wired System. The Sapling Company, Inc Republic Road Huntingdon Valley, PA P F

Sapling Wired System. Synchronized Clock Systems

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Generator protection relay

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION SECTION 16901

multi-function meters

MULTIS L72. Operating instructions

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

ex 800 Series ematrix System

MULTIS LMp / LMg. Systèmes de Coupure et de Protection Switching and Protection Systems

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH)

Process Transmitter RMA 422

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Process transmitter RMA422

Press Publications CMC-99 CMC-141

HOBO H Energy Logger

PiMPro Rack Mount Analyzer

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

dissolved oxygen transmitter

PiMPro Portable Analyzer PiMPro Classic 1821

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

SAPLING MASTER CLOCKS

Model KT 53 Cooling incubators with thermoelectric cooling

Microwave Counter, Power Meter and DVM in One Portable Package

Model ED 23 Drying and heating chambers Classic.Line with natural convection

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Digital Video Recorder

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

We ve got the best technology to fit your power monitoring needs. Scenario works on all!

QRF5000 MDU ENCODER. Data Sheet

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

LAUREL ELECTRONICS, INC.

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

IP Roombox. Hotel Room Management

1/3 RACK-MOUNTED BLOCK CONVERTERS

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

MULTIBAND 1/3 RACK-MOUNTED

SCALE & WEIGHT DISPLAYS

Telephony Training Systems

Multiple Band Outdoor Block Up- and Downconverters

Modular Expansion Cards

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

Single-phase bidirectional energy meter with S0 pulse output

Roof-mounted Blue e+ cooling unit Integration solution VX25

Ensemble QLAB. Stand-Alone, 1-4 Axes Piezo Motion Controller. Control 1 to 4 axes of piezo nanopositioning stages in open- or closed-loop operation

VIDEO MATRIX SWITCHES HDMI 2.0

User Manual Power and Harmonics Analyzer Model PQ3350

A new generation of access control.

GI V E YOUR TA LENT THE TOOL S IT DESERV ES.

High Frequency X-Ray Technology. Wide Screen Control with Touch-Technology

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Magnetic Sensor - Incremental EHP

Model ED 400 Drying and heating chambers Classic.Line with natural convection

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Solis Export Power Manager

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

ANTHEM NOW SHIPPING MRX 710 AND MRX 510 A/V RECEIVERS No trade offs: high-end performance with ease of integration.

MPEG4 Digital Recording System THE VXM4 RANGE FROM A NAME YOU CAN RELY ON

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Telephony Training Systems

System Interface Unit SIU-100/100T

T +31 (0) F

Versatile EMS and EMI measurements for the automobile sector

M R X

Operating Instructions

Modular Matrix Solution. Complete A/V Signal Control in One Expandable System.

Data Sheet SPECTRO-3-SLU-BA-ANA + SI-SLU-16. Receiver optics incl. 3-color filter detector (True Color), scratch-resistant optics cover made of glass

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Wall-/Pipe-Mount Level Indicator

PowerLogic power-monitoring units

High performance circuit breakers

Kuhnke Technical Data. Contact Details

OPTICAL POWER METER WITH SMART DETECTOR HEAD

FLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Actuators IC 20, IC 40

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Advanced Test Equipment Rentals ATEC (2832)

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

PRINCIPLES AND APPLICATIONS

Multifunction devices

Lt DELTA USA, Inc

Model KT 170 Cooling incubators with thermoelectric cooling

R e c e i v e r. Receiver

CBF500 High resolution Streak camera

SC24 Magnetic Field Cancelling System

Transcription:

POWER MONITORS ENERIUM RANGE Minimize your energy consumption and optimize your installation From 0.2s critical electricity metering to the collection of metering data on all utilities Electrical feeder analysis: alarms, recordings, harmonics, EN50160 French measurement expert and manufacturer with more than 25 years experience

TERTIARY AND INDUSTRY Launch an energy-saving operation on the basis of the consumption data measured or collected by the ENERIUM power monitors Without disconnection Quick and easy installation and implementation of the ENERIUM power monitors used with our non-intrusive sensors Energy monitoring A turnkey solution with a direct connection between the ENERIUM power monitors and our E.ONLINE 3 energy supervision software Real-time monitoring of the behaviour of your machines or production lines By means of a clear display of your consumption data and the electrical behaviour of your installations ISO 50001 Flexibility ENERIUM power monitors interface very easily with your existing PLCs or TBM/ CTM systems 1989 All-utility data collection ENERIUM power monitors collect the consumption data from all your existing meters or sensors via the pulse or analog inputs Pioneer of the design and manufacture of power monitors in France IEC Guarantee of the best accuracy according to the acknowledged international reference standards: IEC 61557-12, IEC 62053-21/22, etc.

POWER GENERATION, TRANSMISSION AND DISTRIBUTION Control and monitor all your electrical networks with the ENERIUM power monitors analysis functions Performance Measure and meter HV/MV electrical feeders with very high accuracy (0.2s) Toward the digital substation ENERIUM can be upgraded at any time to use IEC 61850 communication via the ELINK 61850 gateway Advanced functions From measurement of harmonic disturbances to detection of voltage events (dips, outages, etc.) Flexibility The analog outputs can be used to transmit the electrical quantities measured (P, V, I, F, etc.) to PLCs, panel meters, etc. Interaction with the environment ENERIUM detects and stores the status changes and triggers the alarm outputs in the event of overruns 6 models to cover all the applications, from simple consumption metering to the most critical measurements Extensive, customizable communication functions

FUNCTIONS Real-time display of the instantaneous, average, min., max. values, etc. Time/date-stamped recording of the min and max. values, etc. Simple, intuitive, customizable navigation for Alarms 16 programmable alarms on instantaneous values, averages, min., max., analog and on-off inputs (circuitbreaker status, for example) Recording of the last 64 events (values reached, dates, times, duration) Flashing of the display in the event of an alarm Graphics for easier data analysis Keys for confirmation and navigation via drop-down menus Connection checks, measurement of the unbalance and display of the phase shift Load factor monitoring (display of V, U, I and P) Indication of connection errors during start-up

quick access to the required information. Recording Indexes, consumption curves (1) (electricity, water, gas, etc.) and temperature curves (1) Critical parameters with triggering according to 3 different modes (date, alarm, on-off input) and possibility of pre/post-trigger) (2) (1) Load curves. (2) Trend curves Preventive maintenance Installation operating time Duration of use of the equipment monitored Quick programming CT ratios and communication parameters configurable on front panel and remotely Protection possible by password Customizable screens Free organization of the information on 3 screens with 4 display lines Harmonic analysis Measurement of THD per phase on U, I and In Spectral analysis up to 50th order per phase on V, U, I and In Power quality Local access via USB cable/ optical head dedicated to : - programming - data reading - software upgrades Graphs for statistical analysis as per EN50160 Log of the last 1,024 events (dips, outages, overvoltages, overcurrents) Waveform capture (V-U-I-In)

CHOOSE YOUR POWER MONITOR Functional specifications ENERIUM 30 ENERIUM 50 ENERIUM 150 ENERIUM 100 ENERIUM 200 ENERIUM 300 ELECTRICAL POWER MULTI-ENERGY POWER QUALITY ** 111/211/221 321 332 232 332 333 Accuracy class (as per IEC 61557-12) 1 0,5 0.5 0.5 0.5 ou 0.2 0.2 Format 96 x 96 mm 96 x 96 mm 96 x 96 mm 144 x 144 mm 144 x 144 mm 144 x 144 mm Backlit LCD screen Version without display Enerium 110 Enerium 210 Enerium 310 Mounting (Enerium 110) (Enerium 210) (Enerium 310) Harmonics Max. order 25 50 25 50 50 Recording function 8 load curves 4 trend curves 1 Alarms Number of alarms 2 16 16 16 16 16 Time/date-stamped recorded events 64 64 64 64 64 Power quality functions Power quality as per EN50160 Waveform capture on V, U, I, In 16 Storage of the last 1,024 time/date-stamped events (dips, outages, overvoltages) Inputs / outputs Max. number of inputs/outputs 1 2 2 8 8 8 Inputs (option) On-off (pulse or alarm mode) 0.1 ou 2 0.1 ou 2 Analog 0, 2, 4, 6 or 8 0, 2, 4, 6 or 8 0, 2, 4, 6 or 8 Outputs (option) On-off (pulse or alarm mode) 1 0.1 or 2 0.1 or 2 0, 2, 4, 6, or 8 0, 2, 4, 6, or 8 0, 2, 4, 6, or 8 Analog 0 0 or 2 0 or 2 0.2 or 4 0.2 or 4 0.2 or 4 Graphs Fresnel Gauges Histograms of harmonic orders Communication interface Optical / USB Front Front Front or rear Front or rear Front or rear Ethernet or RS485 RS485 Metrological LED Other functions Programming on front panel Programming by software * With mounting kit Advantages An optical/usb head dedicated to: Programming Data reading Software upgrades Display of graphs (Fresnel, gauges, harmonics) Version without display for mounting on DIN rail or plate (ENERIUM 110/210/310) Up to 8 on-off or analog inputs/outputs

MAIN SPECIFICATIONS Dimensions ENERIUM 30/50/150 ENERIUM 100/200/300 ENERIUM 110/210/310 RELATED SOFTWARE Configuration, diagnostic, installation and display software dedicated to the ENERIUM range of power monitors Functions Description Status Configuration Diagnostic Display Graphs E.View E.View+ E.View & E.View+ Energy management Display of load curves Comparison of energy consumption and temperature curves Phase shift measurement Commissioning facilitated by simple visual check Measurement of the phase angles and unbalances (V, U, I) E.ONLINE 3, comprehensive software for supervision, analysis and power monitoring Centralizes and consolidates all the data from the power monitors System which provides relevant data for the energy review in the context of ISO 50001 certification Comparison of energy consumption and temperature curves On DIN rail Mounting accessories Plate-mounting Programming and management Configure your power monitors remotely Keep your network architecture ADDITIONAL INFO For your IEC 61850 networks, don t forget to use ENERIUM with the ELINK communication gateway Modernizes the protocol for your measuring equipment without calling into question your choice of power monitors Up to 10 power monitors Certified DNV.GL

TO ORDER Standard products Model Frequency Accuracy class Power supply Communication On-off input On-off outputs Analog outputs Reference ENERIUM 30 50 / 60 HZ 1 230 to 400 Vac/Vdc RS485 0 0 0 P01330823 ENERIUM 30 50 / 60 HZ 1 230 to 400 Vac/Vdc RS485 0 1 0 P01330824 ENERIUM 50 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 0 0 0 P01330805 ENERIUM 50 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 0 0 0 P01330806 ENERIUM 50 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 1 1 0 P01330807 ENERIUM 50 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 1 1 0 P01330808 ENERIUM 150 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 0 0 0 P01330809 ENERIUM 150 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 0 0 0 P01330810 ENERIUM 150 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 0 2 0 P01330811 ENERIUM 150 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 0 2 0 P01330812 ENERIUM 100 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 0 0 0 P01330831 ENERIUM 100 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 2 2 0 P01330832 ENERIUM 200 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc RS485 4 2 0 P01330833 ENERIUM 200 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 2 2 2 P01330834 ENERIUM 210 50 / 60 HZ 0.5 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 8 0 0 P01330835 ENERIUM 300 50 / 60 HZ 0.2 s 80 to 265 Vac / 110 to 375 Vdc RS485 0 0 0 P01330816 ENERIUM 300 50 / 60 HZ 0.2 s 80 to 265 Vac / 110 to 375 Vdc Ethernet 0 0 0 P01330817 ENERIUM 300 50 / 60 HZ 0.2 s 19 to 58 Vdc RS485 0 0 0 P01330818 ENERIUM 300 50 / 60 HZ 0.2 s 19 to 58 Vdc Ethernet 0 0 0 P01330819 Configured products 1 Model 50 ENERIUM 50 - Electrical energy - Load curves - Format 96 x 96 150 ENERIUM 50 + Trend curves - Format 96 x 96 100 ENERIUM 100 - Multi-energy - Trend curves - Format 144 x 144 110 ENERIUM 100 without display - Format 144 x 144 200 ENERIUM 100 + Load curves - Format 144 x 144 210 ENERIUM 200 without display - format 144 x 144 300 ENERIUM 200 + Power quality 310 ENERIUM 300 without display 2 Frequency of network measured 0 50 / 60 Hz 1 400 Hz (except Enerium 100 / 200 class 0.5s / 300) 3 Auxiliary power supply 0 80 to 265 Vac / 110 to 375 Vdc 1 19.2 to 58 Vdc 4 Communication 0 RS485 1 Ethernet Attention: for choices 5, 6, 7 and 8, a maximum of 8 inputs and/or outputs is possible (ENERIUM 100-110/200-210). Attention: for Enerium 50/150, choices 5 and 6 only allow the following combinations: 0-0, 1-1, 2-0, 0-2. 5 Metering (or on-off) inputs Software E.View E.View+ 0 none 1 1 input (ENERIUM 50 / 150 only) 2 2 inputs 4 4 inputs (except ENERIUM 50 / 150) 6 6 inputs (except ENERIUM 50 / 150) 8 8 inputs (except ENERIUM 50 / 150) ENERIUM 1 2 3 4 5 6 7 8 9 P01330601 P01330610 6 On-off outputs 0 none 1 1 output (ENERIUM 50 / 150 only) 2 2 outputs 4 4 outputs (except ENERIUM 50 / 150) 6 6 outputs (except ENERIUM 50 / 150) 8 8 outputs (except ENERIUM 50 / 150) 7 Analog inputs (ENERIUM 100 / 200 only) 0 none 2 2 analog inputs 4 4 analog inputs 6 6 analog inputs 8 8 analog inputs 8 Analog outputs 0 none 2 2 outputs 4 4 outputs (except Enerium 50 / 150) 9 Accuracy class 5 0.5 s (except Enerium 300) 2 0.2 s (ENERIUM 200/210/300/310 only) Example: Enerium 200, 50/60 Hz frequency, 80 to 265 Vac auxiliary power supply, RS485 communication, 2 on-off inputs, no on-off outputs, no analog inputs, no analog outputs, class 0.2 s => order ENERIUM 200 01020002 1-200 2-0 3-0 4-0 5-2 6-0 7-0 8-0 9-2 Accessories Optical head for ENERIUM 50/150 Optical head for ENERIUM 100/110-200/210-300/310 DIN-rail mounting kit for ENERIUM 30/50/150 DIN-rail mounting kit for ENERIUM 100/200/300 Power supply for pour on-off inputs: 85 to 264 Vac/12 Vdc - 3.5 A (42 W) P01330403 P01330401 P01330830 P01330360 ACCJ1004 906 211 571 BS Ed. 1 04/2018 - Document non contractuel Caractéristiques à se faire confirmer à la commande. FRANCE Chauvin Arnoux Energy 16, rue Georges Besse - Silic 44 92182 ANTONY Cedex Tel: +33 1 75 60 10 30 Fax: +33 1 46 66 62 54 info@enerdis.fr www.enerdis.fr UNITED KINGDOM Chauvin Arnoux Ltd Nelson Ct, Flagship Sq, Shaw Cross Business Pk Dewsbury, West Yorkshire - WF12 7TH Tel: +44 1924 460 494 Fax: +44 1924 455 328 info@chauvin-arnoux.co.uk www.chauvin-arnoux.com MIDDLE EAST Chauvin Arnoux Middle East P.O. BOX 60-154 1241 2020 JAL EL DIB - LEBANON Tel: +961 1 890 425 Fax: +961 1 890 424 camie@chauvin-arnoux.com www.chauvin-arnoux.com