Extreme Density Networks Are You Ready?

Similar documents
Are You Leaving Money on the Table? Making Strategic OSP Cable Choices

The Next Wave Building Tomorrow s Network Today. Roger Vaughn Solutions Engineer OFS

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

3M Fiber Closures BPEO

How to Speak Fiber Geek Article 4: Single-Mode Optical Fiber Geometries

FOSC 400. Fiber Optic Splice Closures

Comprehensive Micro Cabling Solutions and Installation Guide

Cable Installation Tips

FOSC 400. Fiber Optic Splice Closure. Features

Customer-Owned Outside Plant

Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD

Cable Installation Tips

The FiberMark1 offers an ideal solution for

New Ultra-Density Fiber Cable Technology for FTTx and Access Markets Using New SpiderWeb Ribbon

Emtelle Aerial Blown Fibre

Public Works Division Lighting District Fiber Optic Specifications April 2009

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

INSTALLATION INSTRUCTIONS

NOTICE. The above identified patent application is available for licensing. Requests for information should be addressed to:

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

Electric Co-op Solutions Guide

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

MPS Webinar Technical Series

HCS - HES Cabling Systems

Selecting the correct cable type for Outside Plant Application

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

OFI-400 Series Optical Fiber Identifiers. OFI-400 Series Models

FOSC 450 C6 and D6 Closures

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Clearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Fiber Optics Redefined

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

OFI Optical Fiber Identifier User s Guide

Lensed Fibers & Tapered Ends Description:

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

3M Fiber Optic Closure System LL

Industry solutions: Broadcast

Optical Distribution Box 300 Installation Guide. Version : R0.0

INSTALLATION INSTRUCTIONS

SECTION FIBER OPTIC STATION CABLES

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

FREEDM Loose Tube Interlocking Armored Cables

Product Catalogue. Fibre Optic Cable

2011 The Practicalities of Fibre Deployment Colin Kirkpatrick

The advantages of using reduced coating diameter optical fibers (200µm) in ADSS cables for deployment in FTTx networks

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

RetractaNet XS. Extractable Solutions for OSP. October 2012

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

3M Coupling Tray FDTC-10S-COUPLINGTRAY

OptiTect Premier Local Convergence Cabinet An Evolant Solutions Product

3M Cold Shrink Splice Kit QS-III 5416A

SLiC Fiber Aerial Closure System

LTX Optical Distribution Panels. Ordering Guide

COPYRIGHT 2011 AXON DIGITAL DESIGN B.V. ALL RIGHTS RESERVED

TECHNICAL SPECIFICATION

IP-LINX. Installation Guide

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

2. Underground Feeder & Distribution Network

Introduction to Fibre Optics

Broadband System - D

Connectix Cabling Systems

NOTICE. The above identified patent application is available for licensing. Requests for information should be addressed to:

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

Splice Closure Fiber (SCF) Family

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F Ribbon Indoor/Outdoor Riser Cable Preparation

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

FIBRE OPTIC CABLE SOLUTIONS

RACKS, ENCLOSURES AND CABLE MANAGEMENT

Impacts on Cable HFC Networks

Micro Cables, Application (Ducts & Accessories, Equipments, Installation)

3M Distribution Box (DDB)

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

HDMI / Video Wall over IP Receiver with PoE

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

Size Matters: When it comes to FTTH deployment in MDUs, less is more. By Linnea Wilkes, Business Development Manager Business White Paper

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

ULTRA HIGH DENSITY SOLUTION GUIDE

FACT Cable Termination Unit

Illumination Challenges in Non- Industrial Vision Applications. Simon Stanley Managing Director ProPhotonix IRL Ltd

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

3M One Pass Mini Fiber Pathway

CABLE S FIBER OUTLOOK SURVEY REPORT

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

Mining and Petrochemical Fiber Optic Cables

S183PM2 ver. 2 / S184PM-SLDF ver 2.

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Micro duct Cable with HDPE Sheath for Installation by Blowing

SLiC Fiber Aerial Closure 533 and 733

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

Instructions. Cable with Armor F CAUTION. October Rev A

Game on! Plug n play. Plug and play with PryTerms our pre-terminated fibre optic cables. Read more

Gel-sealed in-line fiber optic closure

Transcription:

Extreme Density Networks Are You Ready? Derek Whitehurst Director, Global Applications Marketing Corning Optical Communications

ex treme ikˈstrēm/ adjective reaching a high or the highest degree; very great. synonyms: utmost, very great, greatest, greatest possible, maximum, maximal,highest,supreme, great, acut e, enormous, severe, high, exceptional, extraordinary

Extreme Defined Through Fiber Counts

Loose tube, ribbon and micro cables can support very low to very high fiber counts Fiber Counts <12 12 24 36 48 60 72 84 96 108 120 144 156 192 216 228 240 288 360 432 576 720 864 1728 3456 5000+ Loose Tube Ribbon Micro Cable

Loose tube, ribbon and micro cables can support very low to very high fiber counts Fiber Counts <12 12 24 36 48 60 72 84 96 108 120 144 156 192 216 228 240 288 360 432 576 720 864 1728 3456 5000+ Loose Tube Ribbon Micro Cable Standard Density

Loose tube, ribbon and micro cables can support very low to very high fiber counts Fiber Counts <12 12 24 36 48 60 72 84 96 108 120 144 156 192 216 228 240 288 360 432 576 720 864 1728 3456 5000+ Loose Tube Ribbon Micro Cable Standard Density High Density

Loose tube, ribbon and micro cables can support very low to very high fiber counts Fiber Counts <12 12 24 36 48 60 72 84 96 108 120 144 156 192 216 228 240 288 360 432 576 720 864 1728 3456 5000+ Loose Tube Ribbon Micro Cable Standard Density High Density Extreme Density

Extreme Density Network reaching the highest degree of network density forcing a change in how to deploy the network

Past Network Inflection Points Example 1: FTTH Deployment: Standard OSP network deployment practices to the house were not cost effective or fast enough Example 2 Data Center products were not designed to handle the fiber counts in a rack footprint that was necessary to support growth

Inside the data center, speeds are running from 1G up to 400G

Huge Bandwidth Required to Carry Data Between Data Centers 200Tb/S Day 1: You need over 3000 fibers to connect two hyperscale data centers together

Planning for Extreme Density Traditional solutions get very crowded Experienced crews Solutions matched to handle fiber counts Installation deployment times Keeping track of fibers Emergency restoration

Quick Math Shows Staggering Splicing Labor Ribbon Single Fiber Fiber Count 1728F 1728F Number of splices Time per splice Total Splicing Time(hrs) 144 1728 8 minutes ($40 per splice) 4 minutes ($25 per splice) 19 hours 115 hours

Serious Tradeoffs in Cable Selection Fiber Counts <12 12 24 36 48 60 72 84 96 108 120 144 156 192 216 228 240 288 360 432 576 720 864 1728 3456 5000+ Loose Tube

Serious Tradeoffs in Cable Selection Fiber Counts <12 12 24 36 48 60 72 84 96 108 120 144 156 192 216 228 240 288 360 432 576 720 864 1728 3456 5000+ Loose Tube Ribbon

Serious Tradeoffs in Cable Selection Fiber Counts <12 12 24 36 48 60 72 84 96 108 120 144 156 192 216 228 240 288 360 432 576 720 864 1728 3456 5000+ Loose Tube Ribbon Micro Cable

Serious Tradeoffs in Cable Selection Fiber Counts <12 12 24 36 48 60 72 84 96 108 120 144 156 192 216 228 240 288 360 432 576 720 864 1728 3456 5000+ Loose Tube Ribbon Micro Cable Microcable + Multipath Duct

Micro Cables Offer Scalability and Pay As You Go Model

Micro Cables Offer Scalability and Pay As You Go Model Cable designs using single fibers may make sense when extreme density is required over time

Ribbon Cables Can Provide Extreme Density but Cable Diameter Grows Central Tube Ribbon Cable Stranded Tube Ribbon Cable Ribbon stacks contained within a single, central buffer tube Most commonly-used outdoor ribbon cable design 12 to 864 fibers Max OD: 23.4 mm / 0.92 in. First manufactured in 1996 Ribbon stacks contained within stranded buffer tubes Previously, the highest-fibercount cable for outdoor use 288 to 1,728 fibers Max OD: 32 mm / 1.26 in. First manufactured in 1996

New Extreme Density Cable Designs Double Density at Same Size Corning ribbon cables offer tightest fiber control and greatest workability

Largest Central Tube 864 Fibers Double Down on Density Extreme Density 1,728 Fibers Extreme density cable delivers: 0.92 in. 23 mm 1 in. 25 mm 2x the fibers at similar OD Largest Stranded Tube 1,728 Fibers Extreme Density 3,456 Fibers Extreme density cable delivers: 1.26 in. 32 mm 1.26 in. 32 mm 2x the fibers at same OD

Examining the General Cable Family Options Using 2 Inch Duct Loose Tube Cable Micro Cables in Microduct Legacy Ribbon Cable Extreme Density Cable Fibers in a 2 inch duct 720 1,008 1,728 3,456 Cable combination 1 x 432 F 1 x 288 F 7 x 144 F micro cables 1 x 1,728 F stranded tube ribbon 1 x 3,456 F Single cable solution? Mass-fusion splicing? RocketRibbon extreme-density cables: up to 3,456 fibers and fast, efficient splicing in a single cable solution

Similar Results Using 4 Inch Duct In brand new campus DCI deployments, 4 inch ducts are recommended for max. fiber capacity Legacy Ribbon Cables Extreme Density Cables Extreme Density Cables Fibers in a 4 inch duct 6,048 10,368 12,096 Cable combination 3 x 1,728 F 1 x 864 F 6 x 1,728 F 3 x 3,456 F 1 x 1,728 F 70% more fibers than legacy ribbon 100% more fibers than legacy ribbon

Lessons Learned From Inside the Data Center Getting to the right fiber density may be the easy part of the equation

Things You Should Consider Beforehand Do I have the fiber capacity? How many cables will be entering the hardware and can I manage them? How will I manage the fiber once I access the cable? How many splices can my splice trays hold? Will I need transport tubing for routing? Will I need to hop trays? How will I label and keep track of my ribbons?

Ribbon Construction Will Impact Installation Choices Sheared or glued to achieve net feature Net Design Fiber Ribbon Standard Design Fiber Ribbons Conventional ribbon matrix Bar code type ribbon identification system Printed ribbon identification system 12 fibers intermittently connected: ribbons are not solid Ribbons are rolled to achieve total required fiber count Ribbons require a furcation tube for protection against sharp edges in closure/hardware Conventional ribbons: 12 fibers encapsulated in an array Ribbons are stacked and joined to achieve total required fiber count Conventional matrix provides additional protection so ribbons can be used outside closure/hardware

Ribbon Cable Construction Will Impact Installation Choices Cable styles are very different so understanding required cable accessories is important before you open up the cable Have process in place to keep fibers ordered before you open the cable. Incredible fiber volumes to manage Installer must maintain fiber bundling during installation process Furcation tubing may be necessary Ribbonizing tools may be necessary Corning ribbon cables offer tightest fiber control and greatest workability

Having the Ribbon Stacks Protected is Very Important Routing Slack Management Protection

Not Using Furcation Tubing Can Be Catastrophic Routing unprotected ribbons risks damage Difficult to determine ribbon ID after installation

Extreme Density Networks Mean Planning for Lengthy Installation Times 10-15 hours for 1728F splice points 20-30 hours for 3456F splice points

How extreme will future networks get? Fiber Counts <12 12 24 36 48 60 72 84 96 108 120 144 156 192 216 228 240 288 360 432 576 720 864 1728 3456 5000+ Loose Tube Ribbon Micro Cable Standard Density High Density Extreme Density

The Need for Extreme Density Grows as Data Demands Grow Global IP Traffic* 82% of IP traffic will be video by 2021 PB/Mo *Source: Cisco VNI 2017 There is already interest in cables above 3456F

200um Coated Fiber is the Next Step in Driving Greater Fiber Cable Density 200 micron fibers retain the 125 µm glass cladding diameter of conventional fibers for compatibility in splicing operations SMF-28 Ultra 200 is compatible with both cladding- and core-alignment modes in fusion splicing: ~242 µm fiber ~200 µm fiber ~242 µm fiber ~200 µm fiber Cladding alignment Core alignment Once coating has been stripped and fiber ends cleaned, 200 µm fiber splice performance is exactly the same as for ~242 µm fiber As the coating thickness is reduced, extra care should taken when handling 200 µm fiber

Micro Cables are Already Leveraging 200um Fiber Technology 10.5 mm 8.1 mm 8.0 mm 1.25 in (ID) 1.64 in 1.64 in

Compatibility With Existing Ribbons is the Main Hurdle 200um coated fiber ribbon 242um coated fiber ribbon Backward compatibility requires splicing differently spaced ribbons together Note: Ribbons not to scale

Extreme Density Networks Are Here to Stay As bandwidth increases and service offerings increase, more fiber will be pushed deeper into the network Many aspects in an extreme density network are the same as existing networks As fiber counts grow and cables get smaller, other components of the network must scale and shrink as well Scaling with solutions designed for smaller counts will prove to be difficult as the network grows Extra planning up front to match cable, hardware and connectivity solutions is required to scale effectively

QUESTIONS?