Portable in vivo Recording System

Similar documents
New Generation of MEA-Systems: MEA2100-System

Multiwell-MEA-System

- 1 - Programmable Gain Amplifier PGA Manual

Product Overview As of March 2011

MC_Rack Tutorial: MEA Application Examples

Cardio2D and Cardio2D+ Manual

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

PicoScope 6407 Digitizer

WaveNow USB Potentiostat / Galvanostat

We are Smart Ephys: TBSI. Four trusted brands working together for you

ML785 PowerLab/8SP ADInstruments Data Acquisition Systems

CMOS-MEA5000-System Manual

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

R&S RT-Zxx High-Bandwidth Probes Specifications

MEA Amplifier with Blanking Circuit for Inverse Microscopes

PicoScope 6407 Digitizer

CMOS-MEA5000-System Manual

4 MHz Lock-In Amplifier

2 MHz Lock-In Amplifier

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

WaveDriver 20 Potentiostat/Galvanostat System

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

medlab One Channel ECG OEM Module EG 01000

GFT channel Time Interval Meter

USB Smart Power Sensor

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

The Ultimate Long-term EEG Monitoring System

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

R&S RT-Zxx High-Voltage and Current Probes Specifications

Digital SWIR Scanning Laser Doppler Vibrometer

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

SignalTap Plus System Analyzer

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

TASTEPROBE Type DTP-1. Pre-amplifier for recording from contact chemosensilla INSTRUCTIONS

SC26 Magnetic Field Cancelling System

Ensemble QLAB. Stand-Alone, 1-4 Axes Piezo Motion Controller. Control 1 to 4 axes of piezo nanopositioning stages in open- or closed-loop operation

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

SCM820 Digital IntelliMix Automatic Mixer SEAMLESS MIXING. ADVANCED CONTROL.

Digital Storage Oscilloscopes 2550 Series

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 105 MSPS ADC

USB Smart Power Sensor

Ethernet to VGA over IP Converter

Multi Channel Experimenter Manual

2 MHz Lock-In Amplifier

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

MTL Software. Overview

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

R-1580A Microwave Downconverter. Product Brochure

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio

PicoScope 4000 Automotive PC Oscilloscopes

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

Digital SWIR Scanning Laser Doppler Vibrometer

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

PicoScope 3000 Series Automotive User guide

Fiber-coupled light sources

MS-32 OSCILLOSCOPE MIXED SIGNAL OPTION. Add 32 Digital Channels to a 4 Channel Oscilloscope

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

DPD80 Visible Datasheet

DM8000. # Designed and engineered in the U.K. Advanced Digital Audio Processor

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

MULTIMIX 8/4 DIGITAL AUDIO-PROCESSING

USB Smart Power Sensor

PicoScope 2000 Series PC Oscilloscopes

FAST MOBILITY PARTICLE SIZER SPECTROMETER MODEL 3091

What to look for when choosing an oscilloscope

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

3GSDI to HDMI 1.3 Converter

DIGITAL SPEAKER MANAGEMENT UK

Datasheet SHF A Multi-Channel Error Analyzer

Portable Performance for Debug and Validation

CATALOG NUMBER: HK-MX-VGA-X-Y Product Name

Operating Instructions

inuke NU6000/NU3000 NU1000/NU6000DSP NU3000DSP/NU1000DSP

DPD80 Infrared Datasheet

DisplayPort to HDMI Multi-Monitor Splitter - 3-Port MST Hub

Increase productivity with multiple screens

User s Manual of Signal Level Meter TABLE OF CONTENTS

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

EAN-Performance and Latency

Video VBOX Lite RLVBVD10LT2. Powerful VBOX data logging and video technology in a user-friendly, affordable product. What can Video VBOX Lite do?

HK-DID-MXA-VGA-X-Y. Product Name. Describe. Application. Characteristic. Product Model. Screen Matrix Switcher

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01

PicoScope 3000 Series PC Oscilloscopes

DisplayPort to DisplayPort Multi-Monitor Splitter - 3-Port MST Hub

R&S ZVA110 Vector Network Analyzer Specifications

Introduction to the oscilloscope and digital data acquisition

DB-VRC4H 4K HDMI Compact Video Wall Controller with 45 degree screen rotation

OPTICAL POWER METER WITH SMART DETECTOR HEAD

SC24 Magnetic Field Cancelling System

R&S RT-ZM Modular Probe System

LAUREL ELECTRONICS, INC.

Transcription:

Portable in vivo Recording System 16 or 32 channel version Pre- and filter amplifier included USB 2.0 data transfer Adapters for commercially available probes Real-time signal detection and feedback

Flexible and easy to use software The data acquisition and analysis program MC_Rack is highly adaptable with essentially unlimited possibilities. For routine lab work, the program is set up like an instrument rack on a workbench: Combine virtual instruments (e.g. oscilloscope, filter, spike sorter, and many more). The Portable-ME-System fulfills three functions in one device: The Portable-ME-System is a complete plug-and-play data acquisition system 1. Signal amplification Includes all components you need to start your experiment immediately. Miniature preamplifiers with 8, 16 and Complete all-in-one solution for a variety of in vivo and in vitro applications. Easy installation saves time for your real objectives. No restriction to a certain computer. Can be used with any PC or laptop 32 channels available. Integrated filter amplifier: includes a common ground and one reference between the electrodes and one reference electrode - providing a own. Use this configuration in any lab of your choice. Any question? Take advantage of our more than 15 years of experience. Our support team will be open for all your queries. resolution. It is possible to monitor any channel as an audio the brain. All relevant parameters can be monitored online exporting, etc. on all channels. The screenshot on the right shows data from Extract parameters like spike rates in online or offline analysis. Apply several virtual filters with different cutoff frequencies e.g. an electrode array chronically implanted in a rat brain. Spikes are sorted online, overall spike rate and unit-specific ISI are monitored simultaneously. to separate spike activity from local field potentials. Real-time signal detection and feedback Personal Computer/ Laptop The real-time signal detection/feedback is an advantageous feature if you Download settings before experiment Data acquisition from 16 or 32 need fast and predictable reactions related to recorded analog signals Surface mapping without time delay. Flexible microelectrode arrays based on Before, the signal had to be analyzed by the computer, which led to an 16 bit digital input and output. unpredictable time delay of the stimulus of at least 100 ms. By moving the Sampling rate of up to 50 khz per analysis from the PC to the DSP (Digital Signal Processor) integrated in the channel. Portable-ME-System, the detour is obsolete and the time delay is now far polyimide foil can be used to record from a large area at the surface of brain or heart in vivo or ex vivo. The flexibility of the array allows an optimal electrode-to- below 1 ms. All you need to do is to define the condition for the feedback Real-time sound output for software tissue contact on uneven surfaces. The and download it to the portable-me-system (1). During recording (2), the selectable channels. image on the left shows signals recorded DSP filters the data and detects spikes (3), checking whether your condition True USB 2.0 transfer rate. is fulfilled. When a designated event is detected, the connected stimulus 3. Online and offline analysis through generator generates the stimulus pulse (4). MPA32 included software MPA8 µpa32 Flexible data stream management. You need a specific solution for your setup? Monitor parameters during the running The µpa16 and µpa32 connect directly to probes with Omnetics experiment or re-run it any number of connectors, such as the probe packages CM or H from times. Software updates free of charge. or chronically implanted electrodes can be recorded with high output in real-time, which helps positioning the electrode in vivo electrode arrays on the market. Spike activity from acute Select any permutation of data streams for displaying, analyzing, channels The Portable-ME-Systems are compatible with all kinds of in computer. superior common-mode noise rejection. 2. oriented template racks or design your based on signal processing technology. electrode input, which allows the measurement of the voltage difference Virtual instrument rack: Use task- Acute and chronic in vivo recordings µpa16 from a rat barrel cortex with a 32-channel FlexMEA. Signals are averaged and high pass filtered and the minimum of the first signal component is monitored online. MC_Rack export features You can easily export graphics as bitmap or ASCII directly from the software to your presentation or spreadsheet. Or just pick your favourite If you want to use other probes: No problem. As a standard offline analysis tool. The data file format is compatible with various we can offer the following solutions Cardio 2D programs, like NeuroExplorer and Spike 2. Cardio2D is a software package to record cardiac MC_Rack also supports Neuroshare- a data and analyze for spatial properties of cardiac for you: universal file format for data recorded with signal propagation. and chronic probes from electrophysiological methods as used e.g. by FIND (a novel tool for spike data analysis - With the Portable-ME-System it is possible to Adapters for many acute Adapters for Matrix electrodes from FHC Inc. Do we have the right adapter for you? If not, please do not hesitate to ask us. We will certainly find a solution that fits to your needs, too. http://find.bccn.uni-freiburg.de). As an additional tool you can use the powerful data file handling of MC_DataTool: export raw data or spike cutouts from selected channels of interest as Axon Binary File (*.abf), ASCII file (*txt), or as binary file (*.raw). perform epicardial mapping recordings or map signal propagation in cardiac slices. Cardio2D obtains false color coded maps with isochronous lines for local activation times. Conduction velocity is calculated automatically.

Flexible and easy to use software The data acquisition and analysis program MC_Rack is highly adaptable with essentially unlimited possibilities. For routine lab work, the program is set up like an instrument rack on a workbench: Combine virtual instruments (e.g. oscilloscope, filter, spike sorter, and many more). The Portable-ME-System fulfills three functions in one device: The Portable-ME-System is a complete plug-and-play data acquisition system 1. Signal amplification Includes all components you need to start your experiment immediately. Miniature preamplifiers with 8, 16 and Complete all-in-one solution for a variety of in vivo and in vitro applications. Easy installation saves time for your real objectives. No restriction to a certain computer. Can be used with any PC or laptop 32 channels available. Integrated filter amplifier: includes a common ground and one reference between the electrodes and one reference electrode - providing a own. Use this configuration in any lab of your choice. Any question? Take advantage of our more than 15 years of experience. Our support team will be open for all your queries. resolution. It is possible to monitor any channel as an audio the brain. All relevant parameters can be monitored online exporting, etc. on all channels. The screenshot on the right shows data from Extract parameters like spike rates in online or offline analysis. Apply several virtual filters with different cutoff frequencies e.g. an electrode array chronically implanted in a rat brain. Spikes are sorted online, overall spike rate and unit-specific ISI are monitored simultaneously. to separate spike activity from local field potentials. Real-time signal detection and feedback Personal Computer/ Laptop The real-time signal detection/feedback is an advantageous feature if you Download settings before experiment Data acquisition from 16 or 32 need fast and predictable reactions related to recorded analog signals Surface mapping without time delay. Flexible microelectrode arrays based on Before, the signal had to be analyzed by the computer, which led to an 16 bit digital input and output. unpredictable time delay of the stimulus of at least 100 ms. By moving the Sampling rate of up to 50 khz per analysis from the PC to the DSP (Digital Signal Processor) integrated in the channel. Portable-ME-System, the detour is obsolete and the time delay is now far polyimide foil can be used to record from a large area at the surface of brain or heart in vivo or ex vivo. The flexibility of the array allows an optimal electrode-to- below 1 ms. All you need to do is to define the condition for the feedback Real-time sound output for software tissue contact on uneven surfaces. The and download it to the portable-me-system (1). During recording (2), the selectable channels. image on the left shows signals recorded DSP filters the data and detects spikes (3), checking whether your condition True USB 2.0 transfer rate. is fulfilled. When a designated event is detected, the connected stimulus 3. Online and offline analysis through generator generates the stimulus pulse (4). MPA32 included software MPA8 µpa32 Flexible data stream management. You need a specific solution for your setup? Monitor parameters during the running The µpa16 and µpa32 connect directly to probes with Omnetics experiment or re-run it any number of connectors, such as the probe packages CM or H from times. Software updates free of charge. or chronically implanted electrodes can be recorded with high output in real-time, which helps positioning the electrode in vivo electrode arrays on the market. Spike activity from acute Select any permutation of data streams for displaying, analyzing, channels The Portable-ME-Systems are compatible with all kinds of in computer. superior common-mode noise rejection. 2. oriented template racks or design your based on signal processing technology. electrode input, which allows the measurement of the voltage difference Virtual instrument rack: Use task- Acute and chronic in vivo recordings µpa16 from a rat barrel cortex with a 32-channel FlexMEA. Signals are averaged and high pass filtered and the minimum of the first signal component is monitored online. MC_Rack export features You can easily export graphics as bitmap or ASCII directly from the software to your presentation or spreadsheet. Or just pick your favourite If you want to use other probes: No problem. As a standard offline analysis tool. The data file format is compatible with various we can offer the following solutions Cardio 2D programs, like NeuroExplorer and Spike 2. Cardio2D is a software package to record cardiac MC_Rack also supports Neuroshare- a data and analyze for spatial properties of cardiac for you: universal file format for data recorded with signal propagation. and chronic probes from electrophysiological methods as used e.g. by FIND (a novel tool for spike data analysis - With the Portable-ME-System it is possible to Adapters for many acute Adapters for Matrix electrodes from FHC Inc. Do we have the right adapter for you? If not, please do not hesitate to ask us. We will certainly find a solution that fits to your needs, too. http://find.bccn.uni-freiburg.de). As an additional tool you can use the powerful data file handling of MC_DataTool: export raw data or spike cutouts from selected channels of interest as Axon Binary File (*.abf), ASCII file (*txt), or as binary file (*.raw). perform epicardial mapping recordings or map signal propagation in cardiac slices. Cardio2D obtains false color coded maps with isochronous lines for local activation times. Conduction velocity is calculated automatically.

Flexible and easy to use software The data acquisition and analysis program MC_Rack is highly adaptable with essentially unlimited possibilities. For routine lab work, the program is set up like an instrument rack on a workbench: Combine virtual instruments (e.g. oscilloscope, filter, spike sorter, and many more). The Portable-ME-System fulfills three functions in one device: The Portable-ME-System is a complete plug-and-play data acquisition system 1. Signal amplification Includes all components you need to start your experiment immediately. Miniature preamplifiers with 8, 16 and Complete all-in-one solution for a variety of in vivo and in vitro applications. Easy installation saves time for your real objectives. No restriction to a certain computer. Can be used with any PC or laptop 32 channels available. Integrated filter amplifier: includes a common ground and one reference between the electrodes and one reference electrode - providing a own. Use this configuration in any lab of your choice. Any question? Take advantage of our more than 15 years of experience. Our support team will be open for all your queries. resolution. It is possible to monitor any channel as an audio the brain. All relevant parameters can be monitored online exporting, etc. on all channels. The screenshot on the right shows data from Extract parameters like spike rates in online or offline analysis. Apply several virtual filters with different cutoff frequencies e.g. an electrode array chronically implanted in a rat brain. Spikes are sorted online, overall spike rate and unit-specific ISI are monitored simultaneously. to separate spike activity from local field potentials. Real-time signal detection and feedback Personal Computer/ Laptop The real-time signal detection/feedback is an advantageous feature if you Download settings before experiment Data acquisition from 16 or 32 need fast and predictable reactions related to recorded analog signals Surface mapping without time delay. Flexible microelectrode arrays based on Before, the signal had to be analyzed by the computer, which led to an 16 bit digital input and output. unpredictable time delay of the stimulus of at least 100 ms. By moving the Sampling rate of up to 50 khz per analysis from the PC to the DSP (Digital Signal Processor) integrated in the channel. Portable-ME-System, the detour is obsolete and the time delay is now far polyimide foil can be used to record from a large area at the surface of brain or heart in vivo or ex vivo. The flexibility of the array allows an optimal electrode-to- below 1 ms. All you need to do is to define the condition for the feedback Real-time sound output for software tissue contact on uneven surfaces. The and download it to the portable-me-system (1). During recording (2), the selectable channels. image on the left shows signals recorded DSP filters the data and detects spikes (3), checking whether your condition True USB 2.0 transfer rate. is fulfilled. When a designated event is detected, the connected stimulus 3. Online and offline analysis through generator generates the stimulus pulse (4). MPA32 included software MPA8 µpa32 Flexible data stream management. You need a specific solution for your setup? Monitor parameters during the running The µpa16 and µpa32 connect directly to probes with Omnetics experiment or re-run it any number of connectors, such as the probe packages CM or H from times. Software updates free of charge. or chronically implanted electrodes can be recorded with high output in real-time, which helps positioning the electrode in vivo electrode arrays on the market. Spike activity from acute Select any permutation of data streams for displaying, analyzing, channels The Portable-ME-Systems are compatible with all kinds of in computer. superior common-mode noise rejection. 2. oriented template racks or design your based on signal processing technology. electrode input, which allows the measurement of the voltage difference Virtual instrument rack: Use task- Acute and chronic in vivo recordings µpa16 from a rat barrel cortex with a 32-channel FlexMEA. Signals are averaged and high pass filtered and the minimum of the first signal component is monitored online. MC_Rack export features You can easily export graphics as bitmap or ASCII directly from the software to your presentation or spreadsheet. Or just pick your favourite If you want to use other probes: No problem. As a standard offline analysis tool. The data file format is compatible with various we can offer the following solutions Cardio 2D programs, like NeuroExplorer and Spike 2. Cardio2D is a software package to record cardiac MC_Rack also supports Neuroshare- a data and analyze for spatial properties of cardiac for you: universal file format for data recorded with signal propagation. and chronic probes from electrophysiological methods as used e.g. by FIND (a novel tool for spike data analysis - With the Portable-ME-System it is possible to Adapters for many acute Adapters for Matrix electrodes from FHC Inc. Do we have the right adapter for you? If not, please do not hesitate to ask us. We will certainly find a solution that fits to your needs, too. http://find.bccn.uni-freiburg.de). As an additional tool you can use the powerful data file handling of MC_DataTool: export raw data or spike cutouts from selected channels of interest as Axon Binary File (*.abf), ASCII file (*txt), or as binary file (*.raw). perform epicardial mapping recordings or map signal propagation in cardiac slices. Cardio2D obtains false color coded maps with isochronous lines for local activation times. Conduction velocity is calculated automatically.

Technical specifications Headstage Preamplifiers Headstage MPA8I MPA32I µpa16 µpa32 Dimensions (W x D x H) 17 x 25 x 2 mm 27 x 36 x 5 mm 21 x 17 x 2.5 mm 24 x 25 x 3 mm Weight (w/o cable and plug) Max. tensile strength of cable Input connector type Number of input channels Input voltage 1.3 g 7.0 g 1.5 g 2.0 g 20 N 20 N 20 N 20 N Single-row precision sockets; 50 mil (1.27 mm) grid pattern for 0.35-0.45 mm round pin Dual-row precision sockets; 50 mil (1.27 mm) grid pattern for 0.35-0.45 mm round pins 18-pin dual-row Omnetics A79039-001 (NSD- 18-DD-GG with 2 guide posts, female) 8 32 16 32 ± 500 mv (with respect to a supply voltage of 5 V) 36-pin dual-row Omnetics A79023-001 (NSD- 36-DD-GS with 4 guide posts, female) ± 250 mv (with respect to a supply voltage of 2.5 V) Input impedance 1 TΩ (@1 khz) 1 GΩ (@1 khz) Input capacitance 10 pf 13 pf Input noise < 1.5 μvrms (1 Hz to 5 khz, inputs short-circuited) < 1.2 μv RMS (0.1 Hz to 10 Hz, inputs shortened) Noise density e n = 15 nv/ Hz @ 1 khz e n = 10 nv / Hz @ 1 khz Bandwidth DC to 50 khz DC to 50 khz Gain 10 10 Filter amplifier: Number of input channels 16 or 32 Input voltage AC coupled Input impedance 300 Ω Input noise < 1 μv RMS (full bandwidth, inputs short-circuited) Noise density @ 1 khz e n = 9 nv/ Hz @ 1 khz Bandwidth 1-5000 Hz * Filter slope 80 db/decade Gain 100 * * Other gain and filter settings available on request Data acquisition: Sampling frequency Up to 50 khz/ channel Data resolution 16 bit Crosstalk (channel to channel) Typically 0.01 %, max. 0.1 % Number of analog input channels 16 or 32 Number of digital input channels 16 TTL (CMOS 3.3V TTL Level) Number of digital output channels 16 TTL (CMOS 3.3V TTL Level) Interface and connectors: Analog inputs (16 channel version) 2 x 15-pin D-SUB for MPA8I 1 x 26-pin HD D-SUB for µpa16 Analog inputs (32 channel version) 2 x 26-pin HD D-SUB for µpa16 1 x 44-pin HD D-SUB for µpa32 16bit digital input and output 68 Pin SCSI-type Data transfer USB 2.0 High Speed (true USB 2.0 transfer rate) MC_Rack program: Operating system Data export XP, Vista, 7 or 8 (English and German versions supported) Axon Binary File (*.abf), ASCII file (*.txt), binary file (*.raw) format;.net DLL for use with your own software available

Distributed by: Multi Channel Systems MCS GmbH 2014 Multi Channel Systems MCS GmbH Product information is subject to change without notice. Products that are referred to in this document may be either trademarks and/or registered trademarks of the respective owners. The publisher and the author make no claim to these trademarks. Aspenhaustraße 21 72770 Reutlingen Germany Fon +49-7121-9 09 25 25 Fax +49-7121-9 09 25 11 sales@multichannelsystems.com www.multichannelsystems.com