Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Similar documents
A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

Optimization of a triode-type cusp electron gun for a W-band gyro-twa

RF Power Generation II

STUDIES OF ENHANCED EDGE EMISSION OF A LARGE AREA CATHODE *

Development of High Power Vacuum Tubes for Accelerators and Plasma Heating

This work was supported by FINEP (Research and Projects Financing) under contract

INFN School on Electron Accelerators. RF Power Sources and Distribution

INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

Detailed Design Report

A New 4MW LHCD System for EAST

Development of high power gyrotron and EC technologies for ITER

Defense Technical Information Center Compilation Part Notice

Klystron Tubes. Two forms of such a device, also called linear beam klystron, are given in the following figure.

DESIGN AND TECHNOLOGICAL ASPECTS OF KLYSTRON DEVELOPMENT

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

SLAC-PUB-2380 August 1979 (A)

CPI Gyrotrons For Fusion EC Heating

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

NEW METHOD FOR KLYSTRON MODELING

Recent ITER-Relevant Gyrotron Tests

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

Effect on Beam Current on varying the parameters of BFE and Control Anode of a TWT Electron Gun

RF POWER GENERATION FOR FUTURE LINEAR COLLIDERS* 1. Introduction

DEVELOPMENT OF X-BAND KLYSTRON TECHNOLOGY AT SLAC

The Time-of-Flight Detector for the ALICE experiment

Chris Gilmour Studies into the Design of a Higher Efficiency Ku Band ring-loop Travelling Wave Tube SWS using the CST PIC Software.

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

High-power klystrons. The benchmark in scientific research. State-of-the-art RF sources for your accelerator

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

RECENT PROGRESS IN UPGRADE OF THE HIGH INTENSITY THzzz zz-fel AT OzSAKzA UNIVERSITYzzzz

Triggered breakdown in lowpressure hollow cathode (pseudospark) discharges

RF Solutions for Science.

A SHEET-BEAM KLYSTRON PAPER DESIGN

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

Low-Noise, High-Efficiency and High-Quality Magnetron for Microwave Oven

Uniformity of Plasma Density and Film Thickness of Coatings Deposited Inside a Cylindrical Tube by Radio Frequency Sputtering

Compact, e-beam based mm-and THzwave light sources

CLIC Feasibility Demonstration at CTF3

45 MW, 22.8 GHz Second-Harmonic Multiplier for High-Gradient Tests*

Pulsed Klystrons for Next Generation Neutron Sources Edward L. Eisen - CPI, Inc. Palo Alto, CA, USA

THE NEXT LINEAR COLLIDER TEST ACCELERATOR: STATUS AND RESULTS * Abstract

Observation of vacuum arc cathode spot with high speed framing camera

Investigation of Radio Frequency Breakdown in Fusion Experiments

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

Physics of high-current diode

4.4 Injector Linear Accelerator

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

X-Band Klystron Development at

Projection ablation lithography cathode for high-current, relativistic magnetron

An RF Excited Plasma Cathode Electron Beam Gun Design

The field cage for a large TPC prototype

E2V Technologies CX2668A, CX2668AX Air-Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

KLYSTRON GUN ARCING AND MODULATOR PROTECTION

Experimental Results of the Coaxial Multipactor Experiment. T.P. Graves, B. LaBombard, S.J. Wukitch, I.H. Hutchinson PSFC-MIT

Review of Diamond SR RF Operation and Upgrades

Dark current and multipacting trajectories simulations for the RF Photo Gun at PITZ

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

INITIAL TESTING OF THE 6 GHz, ALL-PERMANENT MAGNET, "VOLUME-TYPE" ECR ION SOURCE

CX1725W Liquid Cooled, Hollow Anode Two-Gap Metal/Ceramic Thyratron

GENCOA Key Company Facts. GENCOA is a private limited company (Ltd) Founded 1995 by Dr Dermot Monaghan. Located in Liverpool, UK

CHAPTER 4: HIGH ENERGY X-RAY GENERATORS: LINEAR ACCELERATORS. Jason Matney, MS, PhD

TOSHIBA Industrial Magnetron E3328

Etching Part 2. Saroj Kumar Patra. TFE4180 Semiconductor Manufacturing Technology. Norwegian University of Science and Technology ( NTNU )

Operating Experience and Reliability Improvements on the 5 kw CW Klystron at Jefferson Lab

Fig. 1. Hawk switch/load vacuum section in the standard configuration.

IOT RF Power Sources for Pulsed and CW Linacs

2x1 prototype plasma-electrode Pockels cell (PEPC) for the National Ignition Facility

w. B. HERRMANNSFELDT and K. R. EPPLEY

Department of Electronics and Communication Engineering Shrinathji Institute of Technology & Engineering, Nathdwara (Raj.)

IMPROVEMENTS IN LOW POWER, END-WINDOW, TRANSMISSION-TARGET X-RAY TUBES

Startscreen ECEDHA, Phoenix, AZ, March 13, 2011

The PEFP 20-MeV Proton Linear Accelerator

The Construction Status of CSNS Linac

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

XFEL High Power RF System Recent Developments

RF plans for ESS. Morten Jensen. ESLS-RF 2013 Berlin

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

Preliminary Study on Radio Frequency Neutralizer for Ion Engine

Final Report. U.S. Department of Energy Grant Number DE-FG02-04ER83916

PIC Simulation of HPM Generation in an Axial Vircator

Status of RF Power and Acceleration of the MAX IV - LINAC

Lecture 17 Microwave Tubes: Part I

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

KARA and FLUTE RF Overview/status

Nuclear Instruments and Methods in Physics Research A

Available online Journal of Scientific and Engineering Research, 2018, 5(5): Research Article

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

P-224: Damage-Free Cathode Coating Process for OLEDs

HIGH VOLTAGE DISCHARGES AS ELECTRON BEAM SOURCE FOR CALIBRATION MEASUREMENTS UDC: M. Magureanu, N. B. Mandache

These tests will be repeated for different anode positions. Radiofrequency interaction measurements will be made subsequently. A.

Next Linear Collider. The 8-Pack Project. 8-Pack Project. Four 50 MW XL4 X-band klystrons installed on the 8-Pack

Multipaction Breakdown Prediction of Passive Microwave Devices with CST Particle-Studio

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

The ESS Accelerator. For Norwegian Industry and Research. Oslo, 24 Sept Håkan Danared Deputy Head Accelerator Division Group Leader Beam Physics

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Transcription:

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications H. Yin 1*, D. Bowes 1, A.W. Cross 1, W. He 1, K. Ronald 1, A. D. R. Phelps 1, D. Li 2 and X. Chen 2 1 SUPA, Department of Physics, University of Strathclyde, Glasgow, G4 0NG, UK. 2 Department of Electronic Engineering, Queen Mary University of London, London, E1 4NS, UK. *1 Email: h.yin@strath.ac.uk Abstract: Electron beams of micro sizes have been recently extracted from a pseudospark discharge. A three cavity pseudospark-driven 94 GHz klystron has been designed and simulated using the particle-in-cell (PiC) code MAGIC- 2D and modeled with CST Microwave Studio. The simulation results to date look promising. Keywords: Klystron, Pseudospark discharge doi: 10.11906/TST.071-075.2011.09.09 1. INTRODUCTION In recent years radiation sources in the terahertz region (0.1-10THz) have received much interest because of the demand in the fields of plasma diagnosis, radiotherapy and advanced communication, etc. All these applications require compact and inexpensive radiation sources. The klystron is an excellent choice for high frequency generation, due to its high gain, high efficiency and robustness as well as the fact that it may be scaled in size in order to achieve higher frequency operation [1]. Due to the decrease in size as the frequency is increased, there is a need for the electron beam current density to increase in order to achieve reasonable output powers. A pseudospark discharge is a viable possibility in this respect, due to the emitted linear beam s characteristic properties such as high current density and high brightness as well as being self-focusing during its propagation [2, 3]. A pseudospark driven microklystron will be a compact and simple device as no external magnetic guiding field is required. Experimental results of the production of pseudospark-sourced electron beams of diameter in the submillimeter range and 94 GHz klystron simulation results will be presented. 2. PSEUDOSPARK MICRO BEAM EXPERIMENTS Pseudospark (PS) discharge has been studied at Strathclyde University for a number of years with regard to its underlying physics and potential applications [4-9]. Because of its scalability accompanied with its ability to produce a high quality beam, it is an ideal electron beam source for high frequency radiation sources extending from Ka (26.5GHz to 40GHz) band, W (75GHz to 110GHz) band to the terahertz region. The propagation of a PS electron beam is aided by an ion channel formed by the front of the beam resulting in no need for a guide magnetic field, which brings great simplicity and feasibility. Most recently, beams of 200, 100, and 70 microns respectively have been extracted from a single-gap PS discharge. As shown in Figure 1, a single- 71

gap PS discharge chamber is constructed with a 3mm aperture through the anode and cathode, an 8mm insulation disc and a 0.5mm thick collimating disc of 200, 100 and 70 microns apertures each attached to the anode respectively. Corresponding to the beam sizes, the beam currents after the collimating disc are measured in the range of 1A to 300 ma at a beam voltage of 8 kv. This shows the possibility to use the PS beams to drive klystrons for millimetre wave to terahertz radiation generation. At a pressure of 100mTorr, a typical output current was measured as shown in Figure 2 with a collimating disc of 70 micron aperture attached to the anode. It demonstrates an output current of various stages with current from 260mA to 6A corresponding to voltage from 12 kv to 5 kv. This beam is very promising for driving a microklystron. HV Cext Rogowski coil anode P gas inlet hollow cathode drift tube to vacuum pump voltage probe insulator collimator with micron aperture Fig. 1 Schematic of PS micro beam experiment Fig. 2 Typical current and voltage traces of 70 micron PS beam 3. MICROKLYSTRON SIMULATIONS Based on the 200 micron diameter PS sourced electron beam, a three cavity 94 GHz klystron has been designed and simulated using the Particle-In-Cell code MAGIC and modeled by CST Microwave Studio. This 94 GHz klystron is driven by an 8kV electron beam of 80μm radius and 15mA current focused by a 0.6T magnetic field in the simulation, as shown in Fig. 3. MAGIC-2D results revealed a strong amplification signal with a peak power output of 20W, a gain of 20dB and an efficiency of 16.7% when the Q-factors were 880 for the input cavity and 1800 for the other two cavities, as shown in Fig. 4. Simulations were also performed using a modified current and voltage pulse in an attempt to better model device performance with a realistic pseudospark pulse. Voltage was stepped down to an average of 8 kv for 15ns before dropping to zero, whilst a current pulse of peak current 15 ma was timed to coincide with the voltage step, as shown in Fig. 5. 72

Fig. 3 The schematic diagram of the 94 GHz klystron Fig. 4 Strong amplification in the klystron simulation Fig. 5 Pulsed current and voltage traces, 15 ns duration. 4. MICROKLYSTRON DESIGN WITH COUPLER Owing to the precise dimensions involved with high-frequency klystron design and manufacture, coupling was an issue due to the cavities possessing dimensions significantly smaller than waveguide of corresponding frequencies. A solution has been proposed via coupling the input and output cavities to a tapered length of waveguide, gradually increasing to standard waveguide dimensions. In order to compensate for the difference in cut off frequency, the taper is lined with a dielectric material, thus altering the effective cut off frequency along the length of the coupler. The proposed structure was then modeled in CST Microwave Studio. The coupling arm itself shows an expected forward transmission of ~98%, whilst transmission via a modified 73

klystron cavity gives a forward transmission of ~80%. Steps are currently underway to construct and test the coupler and device. Fig. 6 CST Microwave Studio modeled 3-cavity klystron. 5. SUMMARY AND ONGOING WORK A three-cavity klystron which operates at a frequency of 94 GHz, using a pseudospark discharge as a beam source, is currently under investigation. Through the use of the EM modeling packages MAGIC-2D and CST Microwave Studio, it has been possible to construct a realistic model of device performance. Manufacturing and experimental measurements shall begin soon on the 94 GHz klystron, as well as testing of the coupling system. References [1] P. H. Siegel, Terahertz Technology, IEEE Transactions on Microwave Theory and Techniques, 50, 3, 910-928 (2002). [2] M. A. Gunderson and G. Schaefer, Physics and Applications of Pseudosparks, NATO ASI Ser. B, New York: Plenum (1990). [3] K. Frank and J. Christiansen, The Fundamentals of the pseudospark and its applications, IEEE Trans. Plasma Sci. 17, 5, 748-753 (1989). [4] H. Yin, W. He, A.W. Cross, A.D.R. Phelps and K. Ronald, Single-gap pseudospark discharge experiments, J. Appl. Phys., 90, 7, 3212-3218 (2001). [5] H. Yin, A.W. Cross, A.D.R. Phelps, D. Zhu, W. He and K. Ronald, Propagation and post-acceleration of a pseudospark-sourced electron beam, J. Appl. Phys., 91, 8, 5419-5422 (2002). [6] H. Yin, A. W. Cross, A. D. R. Phelps, W. He and K. Ronald, Cherenkov interaction and post-acceleration experiments of high brightness electron beams from a pseudospark discharge, Nucl. Instr. and Meth. in Phys. Res. A, 528, 378-381 (2004). [7] A. W. Cross, H. Yin, W. He, K. Ronald, A.D.R.Phelps, L.C. Pitchford, J. Phys. D: Appl. Phys. 40, 1953 (2007). 74

[8] H. Yin, A. W. Cross, W. He, A. D. R. Phelps, K. Ronald, D. Bowes, and C. W. Roberson, Millimeter Wave Generation from a Pseudospark-sourced electron beam, Phys. Plasmas, 16 (2009). [9] A. W. Cross, Y. Yin, D. Bowes, W. He, K. Ronald and A.D. R. Phelps, "Pseudospark-sourced electron beam for millimetre wave and terahertz generation". New Developments in Nonlinear Plasma Physics, 1188, 380-390 (2009).J. Clerk Maxwell, A Treatise on Electricity and Magnetism, 3 rd ed., 2. Oxford: Clarendon, 68-73 (1892). 75