SMARTXIDE 2 SMARTXIDE 2 ENT SURGERY - ENT. The Only ENT Laser Platform: The Accuracy of the CO 2. Laser and the Flexibility of the Diode Laser

Similar documents
SYNCHRO REPLA:Y SYNCHRO REPLA:Y. NEW: ALEX at 3 Hz! MEDICINE AND AESTHETICS. The First Alexandrite Laser Working at 3 Hz

Litho. Taking care of people, our masterpieces. Surgical Laser System. Surgery

THE UNMATCHED STARS FOR PROFESSIONAL HAIR REMOVAL. Brochure for the U.S.

Most advanced, portable, high-power 532nm Diode-Pumped Solid-State Photocoagulator

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

MC-500 Vixi MC-500. Multicolor Scan Laser Photocoagulator. Multicolor Laser Photocoagulator US EDITION

Multicolor Scan Laser Photocoagulator MC-500 Vixi. Multicolor Laser PhotocoagulatorMC-500

Industrial Diode Laser (IDL) System IDL Series

Multicolor Scan Laser Photocoagulator MC-500 Vixi

MultiFlex An Innovative I 2 PL Device and an Outstanding Nd:YAG Laser in One Versatile Platform

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

25W 9xxnm Uncooled Multimode Laser Diode Module

OPERATOR S MANUAL 80W. Code: OM103P1_G.V06 S/N: Manual revision date: 22-April

Fiber-coupled light sources

IMPAC Infrared Thermometers

CBF500 High resolution Streak camera

TP /2017-E POWER LED 300. Luminous. Efficient. Durable.

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

High productivity rapid manufacturing systems DIGITALWAX X. for general applications

ADVANCED OPTICAL FIBER SOLUTIONS

ModBox-850nm-NRZ-series

Digital SWIR Scanning Laser Doppler Vibrometer

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

Connection for filtered air

Digital SWIR Scanning Laser Doppler Vibrometer

Product Description Sheet Loctite CL10 Quad LED Controller

Light Source. Specification & User Manual

FLIR Daylight and Thermal Surveillance (P/T/Z) Multi-Sensor systems

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

THE ART OF ENGINEERING

OSICS 8-Channel Modular Platform for DWDM Testing

EMC-Scanner. HR-series

Lensed Fibers & Tapered Ends Description:

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

The extremely compact laser head is approximately 480 mm long and can

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

opengear OPG-1L 50 MHz-2.3 GHz

ODW-621. RS-232 Point-to-point applications

CHANGING THE WAY LIGHTING DESIGNERS USE LASERS

ModBox-1310nm-1550nm-28Gbaud-PAM nm & 1550 nm, 28 Gbaud PAM-4 Reference Transmitter

In-process inspection: Inspector technology and concept

IMPAC Infrared Thermometers

The Telegärtner Group

Optical Perfection. HIGHYAG Beam Delivery Products

Intra-oral X-ray unit with high frequency DC generator. Product Data

High productivity rapid manufacturing systems DIGITALWAX D. for dental & Biomedical applications

KVANT. Spectrum 1,6W RGB laser system. Product datasheet

DSM Series Ultra Thin Surface Mount Single Digit 7-Segment LED Display

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

An impressive appearance

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

YXLON Cougar EVO PLUS

Microwave Counter, Power Meter and DVM in One Portable Package

GFT Channel Digital Delay Generator

LONWORKS Fibre Optic Converter

NONDESTRUCTIVE INSPECTION OF A COMPOSITE MATERIAL SAMPLE USING A LASER ULTRASONICS SYSTEM WITH A BEAM HOMOGENIZER

The Art of Engineering

LD OEM/LD PDS/LD PeCo

GI V E YOUR TA LENT THE TOOL S IT DESERV ES.

O-to-E and E-to-O Converters

VIO product family. The right solution for every specialty ELECTROSURGERY

Mainz COLOVIEW System

Contents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2.

Compact EGC Fiber Deep Nodes A90100 and A90300

Fibre Optic Modem ODW-622

istep STEPPER MOTOR PUMP

The Fastest Photocoagulator. Ever.

CPD LED Course Notes. LED Technology, Lifetime, Efficiency and Comparison

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

ModBox-CBand-NRZ series C-Band, 28 Gb/s, 44 Gb/s, 50 Gb/s Reference Transmitters

Photonics solutions For innovative photonics

What is a Visual Presenter? Flexible operation, ready in seconds. Perfect images. Progressive Scan vs. PAL/ NTSC Video

LASER SCANNING PRODUCT GUIDE. Industrial Holographic and Conventional Laser 1D, Omnidirectional Bar Code Scanners

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

Dental Line. High frequency intraoral x-ray unit. radiology ahead

Advanced Test Equipment Rentals ATEC (2832)

Polygon Scanners Capabilities, Applications and System integration. considerations

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

istep STEPPER MOTOR PUMP

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

VISERA 4K UHD GET CLOSER. GET CLOSER Four Times the Resolution of Full HD.

MAP Optical Power Meter Module (mopm-b1)

Features. Applications R TOP VIEW

Prisma Optical Networks Ancillary Modules

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

The extremely compact laser head is approximately 480 mm long and can

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

MTS/T-BERD 8000 Platform

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

Features. Applications R TOP VIEW

Surgical Solutions. Brilliance. Focus. Comfort. HarmonyAIR M-Series Surgical Lighting System. One Integrated Approach to Healthcare

Explore the Art of Detection

Transcription:

SMARTXIDE 2 ENT SURGERY - ENT SMARTXIDE 2 The Only ENT Laser Platform: The Accuracy of the CO 2 Laser and the Flexibility of the Diode Laser ENT Microsurgery General Surgery DEKA Proprietary Technology: Electronic Scanning Systems and Micro Spot Micromanipulators DEKA: Excellence in Robotic Surgery

SMARTXIDE 2 10 THE SMARTXIDE 2 REVOLUTION: ABSOLUTE PRECISION AND CONTROL FOR THE MOST ADVANCED MICROSURGERY The use of CO 2 has considerably improved the performance of ENT microsurgery. Today CO 2 laser is universally recognised as the gold standard for mininvasive ear, nose and throat applications. DEKA, a world leader in the development of high tech laser systems, concentrated over thirty years of expertise into the technological excellence of SmartXide 2 The synergistic interaction of SmartXide 2 : - CO 2 RF laser source with PSD (Pulse Shape Design) technology, - high precision scanning system (HiScan Surgical), - micromanipulator with exclusive Hybrid technology provides unparalleled performance of ENT applications. In line with its ongoing commitment to innovation, DEKA paved the way for a new, multidisciplinary, avant-garde laser system: The SmartXide 2 now featuring a diode laser module with power up to 50W. This modularity makes it the only worldwide CO 2 laser platform. The DEKA CO 2 laser, with progressive scanning technology makes operations simpler and safer on delicate tissues like the vocal cords. It s a wonderful instrument for selective reconstruction procedures of the respiratory tract, with a series of significant benefits ranging from control of the ablation depth, to reduced thermal damage plus the fact of no longer having to depend on the movements of the surgeon s hand which are not always accurate. Guillermo Campos, M.D. Director - Instituto de Laringología Consultant Department of Surgery, Fundación Santa Fé University Hospital, Bogotá DC, Colombia Thanks to the precision and repetitiveness that only scanning technology can offer, the new HiScan Surgical scanner system has greatly simplified the performing of delicate and complex surgery such as laser Stapedotomy. Stefano Dallari, M.D. Director of the ENT Operating Unit A. Murri Hospital, Fermo, Italy

SURGERY - ENT SMARTXIDE 2 DEKA TECHNOLOGIES: BEYOND PROGRESS WITH SMARTXIDE 2 The technological evolution and ongoing scientific research carried out in the DEKA laboratories and highly specialised world centres, have pushed the SmartXide 2 design beyond the current use boundaries with a decisive impact on ENT laser technology. DEKA innovative CO 2 RF laser source equipped with the exclusive PSD (Pulse Shape Design) technology generates pulses especially designed for surgical applications and the use of lasers in total synergy with the HiScan Surgical scanning system. SmartXide 2 is an extremely versatile platform combining CO 2 and diode lasers. PSD Technology The first RF CO 2 laser system with the exclusive Pulse Shape Design technology that enables the maximum flexibility of the pulse shape; from real continuous to U-Pulse. 2 Different wavelengths, CO 2 and diode (with a choice of 940 nm or 980 nm) in a single platform. Database Multimedia features Integrated protocols designed for ENT surgery. Integrated photo and video tutorial. 2 Selectable ablation modes: Depth and Power. 6 Scanning figures: lines, curves of a circle (and full circles), spirals, hexagons (with progressive and interlaced scanning), clover. 4 Scanning functions controlled by the joystick: rotation, sizing, Scan On/Off, beam centering. H Version Hybrid Technology Holographic lens and mirrors for perfect focusing of the laser beams, producing micro spots and the largest scanning figures on the market (max. diameter 6.3 mm).

kw Ablation U-Pulse (UP) 10 RF CO 2 LASER SOURCE WITH PSD TECHNOLOGY: VERSATILITY WITHOUT COMPROMISES Power The development of RF CO 2 laser source equipped with the exclusive PSD (Pulse Shape Design) technology allowed DEKA to create a CO 2 laser system with high emission versatility and capable of generating optimal pulses for multidisciplinary applications designed especially for ENT surgery. Pulse Duration µs The special features of this new source and its power supply make it possible to create fractioned laser pulses with variable structure, durations and peak powers, something hitherto unknown in CO 2 laser systems. High energy delivered in microsecond pulses. U-Pulse: the Best Ultrapulse for ENT Microsurgery The ideal pulse for ENT laser microsurgery must feature the highest possible peak power and shortest duration in order to minimise the thermal effects on the surrounding tissues. Excellent ablation capabilities with no charring. HISCAN SURGICAL: NEW ADVANCEMENT IN SCANNER-ASSISTED MICROSURGERY HiScan Surgical is a double-galvanometer system patented by DEKA. It allows the robotic technology use in microsurgery. The laser beam focused by the zoom of the hybrid micromanipulator in spots of few microns is rapidly moved offering: optimal scanning figures for cutting and ablation of tissues; minimum lateral thermal damage to tissues; selection of the ablation depth of each single scan (depth mode); reduced learning curve. HiScan Surgical can generate the most suitable scanning shapes in ENT microsurgery, including: points, lines, curves and complete circles, spirals, hexagons (progressive and intertwined scanning), double interpolated ellipses.

EASYSPOT HYBRID MICROMANIPULATOR: THE NEW GOLD STANDARD IN MICROSURGERY EasySpot Hybrid offers exclusive technical advantages in microscopic surgery offering full control in areas requiring extreme precision and utmost accuracy. Combining holographic lens and high reflectivity mirrors hybrid technology produces micro spots and the largest scanning figures on the market. The main scanning functions are microswitch-controlled by the joistick allowing the surgeon to operate without ever taking his eyes off the microscope. These are the technological innovations offered by the HiScan Surgical and Easyspot Hybrid that make them the most ergonomic and versatile systems on the market today: EasyField system: Full control of the beam even inside a limited operating field, through gradual mechanical adjustment of the maximum working field. EasyFocus system: A single ring-nut with a mechanical lock of the focal point that enables swift and intuitive focusing and defocusing operations. EasyPlug system: Simple connections and internal wiring optimise the design and the ergonomy of the equipment. HISCAN Surgical scanning system coupled with EasySpot Hybrid micromanipulator. Remote Control The microswitch located on top of the joystick allows physicians to control all the main scanning functions without taking their eyes off the operating microscope. The joystick makes it possible to: Thanks to the remote control located on the joystick, all the main functions are under the surgeon s direct control without ever taking his eyes off the microscope. control the rotation and size of the ablation figures; select the Scan On/Off mode immediately; set the beam centering in the accessories with the utmost precision.

10 INTEGRATED DIODE LASER (OPTIONAL) The diode laser is well known in ENT due to its user-friendliness and the benefits offered by a flexible fibre optic transmission system, especially for difficult areas like the nose and ears. SmartXide 2 is the only CO 2 system that can also be upgraded with an additional diode laser module. Diode laser is available with 2 wavelengths (940 nm or 980 nm) and 2 maximum powers (30 W and 50 W). A wide range of optical fibres from 200 to 600 microns, single use or 10-time sterilisable can be chosen. The flexibility and user-friendliness of the diode laser combined with the speed and precision of the CO 2 laser make SmartXide 2 a unique system worldwide. ONE SHOT, ONE GOAL The 50 Watt diode laser allows to perform the innovative one shot stapedotomy procedure that can also be performed with the CO 2 laser scanned system. Smartxide 2 is the best laser platform for otology in the market. DEKA SOFTWARE: FLEXIBILTY AND KNOW-HOW SERVING THE PHYSICIAN SmartXide 2 new graphic interface is designed to simplify and facilitate control of all the functions available. The large LCD Touch Screen ensures easy selection of the operating parameters. DEKA software: user-friendly right from the start. The integrated database allows for rapid selection of the most suitable settings for carrying out surgery, considerably reducing the learning curve of the system. The multimedia content with photos and videos provides quick and targeted training for the specialists and their staff. SMARTXIDE 2 SYSTEM: UNIQUE, VERSATILE, MULTIDISCIPLINARY Versatility, high performances and efficacy in the pursuit of excellence: the SmartXide 2 system represents a real innovation of CO 2 and diode lasers. A complete series of accessories can be adapted for use in Surgery, Dermatology, Aesthetic, V 2 LR (Vulvo-Vaginal Laser Reshaping) and Dentistry.

THE TECHNOLOGICAL SOLUTION FOR ALL ENT TREATMENTS The multitude of applications and benefits of CO 2 laser in ENT have been known for years. The use of instruments that exploit automated cutting and ablating techniques make it an indispensable system for the surgeon. SmartXide 2, with its EasySpot Hybrid micromanipulator and HiScan Surgical scanner, is the new Gold Standard for laryngeal microsurgery: Cordectomies and Cordotomies Polyps and laryngeal papillomas (including diffuse papillomatosis) cordal nodules Benign neoformations Reinke s oedema Laryngocele Hyperkeratosis laryngitis Scar gangue Granulomas Congenital diaphragms Leukoplachia, and erythroplasia Primary laryngeal tumours Surgery after unsuccessful radiotherapy Paralysis in adduction of the vocal chords Laryngotracheal stenosis Laryngeal Amyloidosis. In the middle ear surgery field, it is possible to perform stapedotomies and myringotomies. Polyp of the left vocal Fold Squamocellular carcinoma (T3) 3 months follow-up 6 months follow-up In oral, pharyngeal, nasal, tracheobronchial and external surgery, SmartXide 2 with its specific accessories is the perfect instrument for excision and ablation of tissues in the case of: Leukoplachias Erythroplasias Papillomas Haemangiomas cancer surgery (e.g. glossectomy) Zenker s diverticulum Choanal atresia LAUP (Laser Assisted Uvulo Palatoplasty) Tonsillotomy and tonsillectomy Turbinate reduction Septoplasty Removal of nasal obstructions, polyps, synechiae Rhinophyma Cheloids and hypertrophic scars Stenosis, Nodules, polyps, tumours of the Tracheobronchial tree Resection of tumours in sub-facial and neck areas Ablation of lesions of the skin and mucosa Otoplasty. Squamocellular carcinoma (T1a) 12 months follow-up Image of the supraglottis in a girl with recurrent respiratory papillomas. Tracheostomy was performed elsewhere and she was referred for treatment After papilloma removal (glottic stenosis is evident) 11 months follow-up (after 4 procedures) One Shot CO 2 laser stapedotomy Courtesy of: Stefano Dallari, M.D. Director of the ENT Operating Unit Hospital of Fermo, Italy. Bilateral vocal fold palsy (after total thyroidectomy) Posterior cordotomy 6 months follow-up Courtesy of: Guillermo Campos, M.D. Director - Instituto de Laringología Consultant - Department of Surgery, Fundación Santa Fé University Hospital, Bogotá DC, Colombia

TECHNICAL DATA SMARTXIDE 2 - Suggested Configurations in ENT Models* C60 and C60H C80 and C80H Laser Type CO 2 RF - PSD Wavelength 10.6 µm Emission Beam TEM 00 Emission Modes CW - SP - DP - HP - UP CW Power From 0.5 to 60 W From 0.5 to 70 W SP Power DP Power From 0.1 to 15 W From 0.2 to 15 W HP Power From 0.1 to 8 W From 0.1 to 15 W UP Power From 0.5 to 60 W From 0.5 to 80 W Emission Time Delay Emission Time Beam Delivery Aiming Beam Internal Database From 0.01 to 0.9 sec. From 0.3 to 5 sec. 7 Mirrors articulated arm with counterweight. Laser diode @ 635 nm - 4 mw - Adjustable intensity from 2% to 100% - Aiming light OFF or Diode OFF while lasing. About 150 factory stored protocols, upgradable by USB. Possibility of storing unlimited number of custom user s protocols. Control Panel Wide LCD Colour Touch Screen (10.4 ). Accessories* Electrical Requirements Dimensions** and Weight HiScan Surgical Scanner System. Hybrid EasySpot Micromanipulator. EndoScan Scanner System. Laser diode @ 940 or 980 nm - 30 or 50 W. Wide range of surgical handpieces. From 100 to 120 Vac - 50/60 Hz From 220 to 230 Vac - 50 Hz - 1,600 VA 162 (H) x 59 (W) x 56 (D) cm - 95 kg for C60 and C80 192 (H) x 59 (W) x 56 (D) cm - 100 kg for C60H and C80H HiScan Surgical Scanner System Max Scanning Area Dwell Time Selectable Ablation Depth Scanning Modes Scanning Shapes Emission Modes Hybrid EasySpot Micromanipulator Optical Technology Spot Size Operative Field @ 400mm EFL Joystick Controls 6.3 mm x 6.3 mm @ 400 mm EFL From 100 μs to 45 ms From 0.2 to 2 mm Power Mode and Depth Mode. Point, Line, Arcs of circle up to complete circle, Spiral, Clover, Hexagon (progressive and interlaced scanning). CW - UP Hybrid - Holographic lens and mirrors. Min 140 μm - Max 4.5 mm Min 20x18 mm - Max 55x40 mm Rotation and ablation shape dimensions, Scan-ON/Scan-OFF, Centering fine tuning. Adaptable to the most common surgical microscopes. EndoScan Scanner System Max Scanning Size Dwell Time Scanning Shapes Emission Modes 5 mm @ 300 mm EFL, 6.3 mm @ 400 mm From 100 to 1,000 μs Cut Mode (Point), Circle, Clover. CW - UP Integrated Laser Diode (optional) Wavelength 940 or 980 nm CW Power 30 W 50 W Operating Modes Exposure Modes Emission time in PW (Ton) Delay Emission Time in PW (Toff) CW and PW Continuous, single pulse, burst or repeated burst. From 5 to 2,000 ms From 5 to 2,000 ms Burst pulses in PW From 2 to 50 Delay between bursts Beam Delivery From 0.5 to 5 sec *In this catalogue only the technical features of the ENT applications are listed. Please refer to the SmartXide 2 General for the complete list of characteristics. ** Height with folded articulated arm. CAUTION Optical Fibers of 200 µm, 300 µm, 400 µm, 500 µm and 600 µm, single use or 10 times sterilisable, with chip; SMA 905 connector. Visible and invisible laser radiation. Avoid eye or skin exposure to direct or scattered radiation. Class 4 laser product. This brochure is not intended for the market of USA. ENT MICROSURGERY - GENERAL SURGERY SURGERY Follow us on www.dekalaser.com Dealer stamp DEKA 003-0126-10-020 Rev. 6.3 DEKA M.E.L.A. s.r.l. Via Baldanzese,17-50041 Calenzano (FI) - Italy Tel. +39 055 8874942 - Fax +39 055 8832884 DEKA The Code of Excellence A spin-off of the El.En. Group, DEKA is a world-class leader in the design and manufacture of lasers and light sources for applications in the medical field. DEKA markets its devices in more than 80 countries throughout an extensive network of international distributors as well as direct offices in Italy, France, Germany, Japan and USA. Excellence is the hallmark of DEKA s experience and recognition garnered in the sphere of R&D in over thirty years of activity. Quality, innovation and technological excellence place DEKA and its products in a unique and distinguished position in the global arena. DEKA manufactures laser devices in compliance with the specifications of Directive 93/42/EEC and its quality assurance system is in accordance with the ISO 9001 and ISO 13485 standards. DEKA M.E.L.A. s.r.l. - All rights reserved - In order to improve its products the company reserves the right to modify these specifications without prior notice. Document Reserved for Health Professionals Only.