Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Similar documents
Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Weighing Scale. 10key&12key User manual

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL ELECTRONICS, INC.

TABLE OF CONTENTS. Instructions:

Extra long-range RFID (proximity) card reader

Ocean Sensor Systems, Inc. Wave Staff XB, OSSI A Wireless Wave Staff with Self-Grounding Coaxial Staffs and Synchronized Sampling

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

IV 251. Signal Converter SSI Analogue and SSI Serial. Operating Instructions. control motion interface

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

SCALE & WEIGHT DISPLAYS

IV 251. Signal Converter SSI => Analogue and SSI => Serial. Operating Instructions. control motion interface

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

ZU 252. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

RF4432 wireless transceiver module

Modbus Register Tables for SITRANS RD300 & WI100

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

Simple PICTIC Commands

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

medlab One Channel ECG OEM Module EG 01000

DCP100 Digital Control Programmer Specifications

Sensopress LCD Special English

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Users guide for PB units Interface unit, 4- or 6-digit

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio

VGA AUDIO SWITCHER S MANUAL

Process Transmitter RMA 422

2 MHz Lock-In Amplifier

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Variable gain and stable detection even at high gains

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

OPTICAL POWER METER WITH SMART DETECTOR HEAD

SPACESCAN SERIES SS 02

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

Magnetic Sensor - Incremental EHP

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Modbus for SKF IMx and Analyst

MAX11503 BUFFER. Σ +6dB BUFFER GND *REMOVE AND SHORT FOR DC-COUPLED OPERATION

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

Kramer Electronics, Ltd. USER MANUAL. Model: FC Analog Video to SDI Converter

TempScan/1100 & MultiScan/1200

PRINCIPLES AND APPLICATIONS

Micro-DCI 53ML5100 Manual Loader

Noise Detector ND-1 Operating Manual

CEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)

8X2 HDMI Switch Splitter

A/D and D/A convertor 0(4) 24 ma DC, 16 bits

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

GWL/ Power Group Technology Solutions Stay Powered for the Future

Absolute Encoders Multiturn

FRQM-2 Frequency Counter & RF Multimeter

Transmitter Interface Program

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

DiD. LCD Video Monitor & Video Wall Universal User Manual. Digital Information Display

V1602 / V1602CP. ANALOGUE VIDEO ROUTER - 16x2. Rev. 6

Model IQ4-PC User Manual Revision Date:

Modular Lube Lubrication Systems System Controls

Instruction Manual Model

SignalTap Plus System Analyzer

Configuration Vestas VMP3500

DATA SHEET Panorama Rudder Indicator, TRI-2

CAT EXT-CAT USER MANUAL

MODEL 2873 Chassis with RS422 CLOCK RECOVERY Module, IOCRM4

Single Axis Position Controller

VideoStamp 8 TM. Eight channel on-screen composite video character and graphic overlay with real-time clock. Version 1.01

Full-featured CW Microwave Counters for Field, Factory or Lab

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

RF Solution for LED Display Screen

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

with Carrier Board OSD-232+ TM Version 1.01 On-screen composite video character and graphic overlay Copyright 2010 Intuitive Circuits, LLC

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Ensemble QLAB. Stand-Alone, 1-4 Axes Piezo Motion Controller. Control 1 to 4 axes of piezo nanopositioning stages in open- or closed-loop operation

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

Operating Instructions ACX-Series Digital Aircraft Cable Tension Meter

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

ZR x1032 Digital Image Sensor

potentiostat/galvanostat

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Projection Display. Serial Interface Specification

Process transmitter RMA422

TELEDYNE HASTINGS INSTRUMENTS

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

L, LTC, LTM, LT are registered trademarks of Linear Technology Corporation. Other product

1. General Specification

SigPlay User s Guide

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

ET-YFB100G S P E C F I L E. Digital Interface Box. As of December Specifications and appearance are subject to change without notice.

Transcription:

Ocean Sensor Systems, Inc. Wave Staff III, OSSI-010-008 With 0-5V & RS232 Output and A Self Grounding Coaxial Staff General Description The OSSI-010-008 Wave Staff III is a water level sensor that combines a rugged, sealed, waterproof package, low power microprocessor and a temperature stable, sensing circuit. The Wave Staff III operates from 5.5V to 40VDC and has analog and RS232 serial data outputs. The serial data output string contains the water level & temperatures in ASCII or binary format. The Wave Staff III can be programmed to free run or sample on demand. It is easily programmed via a PC serial port using our Wave Staff Interface Software. The Wave Staff III has two new features. The Coaxial Cable Staff eliminates the need for a separate water ground wire and both Staff & electrical cord are changeable. Features Accurate Wave, Tide and Water Level Sensor Programmable 0-5V or RS232 Data Out Programmable Sample Rate Up to 30Hz Sample on Command for Simultaneous Sampling Programmable Air Temperature Serial Data Out Rugged Sealed Waterproof Design Changeable Teflon Coated Sensor Cable up to 11 meters Wide Input Voltage 5.5V to 40VDC Low Power Consumption 18 ma Data Accuracy 0.25%, 20-80% of Full Scale Data Accuracy 1.0%, 0-100% of Full Scale Data Resolution 0.025% Data Linearity 0.5% Ordering Information Item Description Staff Type Part Number 1/2 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-0.5C 1 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-1C 1.5 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-1.5C 2 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-2C 3 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-3C 4 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-4C 5 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-5C 6 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-6C 7 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-7C 8 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-8C 9 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-9C 10 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-10C 11 Meter Cable Staff III Teflon Coaxial Cable OSSI-010-008-11C 1

Dimensions and Wire Configuration WIRE COLOR CODE Black / Red Signal and Power Ground Green/Yellow 0 to 5V Analog Output Red Power In 5.5V - 40V White / Red Receive Data to PC Yellow / Red Transmit Data from PC 2

Electrical Characteristics Parameter Conditions Min. Typ. Max. Units Input Voltage 5.5 40 V Input Current 18 23 ma Data Accuracy 20-80% of Full Scale (3) 0.25 ±% Data Accuracy 0-100% of Full Scale 1.0 ±% Data Resolution Percent of Full Scale 0.025 % Data Linearity Percent of Full Scale 0.5 ± % Analog Out (Note 1) 0 5 V Analog Out Noise, Peak % FS (Note 2) 0-1MHz 5 mv RS232 Data Out Noise, Peak % FS 0.025 % Note 1: Accuracy is guaranteed from 8mV to 4.9V with => 5K ohms load. Note 2: Serial Data deselected. Note 3: The unit may need to be calibrated in-situ to meet the Data Accuracy Mechanical Characteristics Parameter Conditions Min. Typ. Max. Units Environment Waterproof 30 meters Cable Tension 0 50 500 Newtons Data and Timing Characteristics Parameter Conditions Min. Typ. Max. Units Sync Sample Delay Command to Start of Data Returned 6 7 ms Free Run Sample Frequency 10 30 Hz Serial Data Baud Rate 9.6 Kbaud Serial Data 0 to Full Scale 1 thru. 11 Meter Staff 0000 4095 counts Temperature Resolution Per 8 counts (Note 4) 0.50 C Temperature Range -10 +65 C Temperature -10 C to 65 C 0.5 Accuracy -40 C to 65 C 2.0 ± C Temp. Update Rate 1 Hz. Note 4: Example: (8 counts = 0.5 Deg. C) -10 Deg. C = -0160 counts - 1 Deg. C = -0016 counts - 0.5 Deg. C = -0008 counts 0 Deg. C = +0000 counts + 0.5 Deg. C = +0008 counts + 1.0 Deg. C = +0016 counts + 65.0 Deg C = +1040 counts 3

Communications and Configuration: The Wave Staff III may be configured with a PC s RS232 serial port. Use our convenient programming software or a Hyper Terminal with the following commands. The serial port settings on your computer are as follows: 9600 baud, 8 data bits, parity none, 1 stop bit, and no flow control. Commands are two bytes and Acknowledgements are 4 bytes Commands: st = Stop running sample routine and wait for command instructions. w = Write configuration data to Wave Staff from PC. r = Read back configuration data to PC. i = Read back ID number to PC. g = Go run main sampling routine. Acknowledgements: STOK = Acknowledge Stop running command and wait for command instruction. WOK = Acknowledge Write configuration and wait to receive data from PC. ROK = Acknowledge Transmit configuration and transmit configuration data to PC. IOK = Acknowledge ID Command and transmit ID (serial) number to PC. GOK = Acknowledge go command and go run main sample and store data routine. BAD = Receive failure or check sum on configuration data error DOW = Do, write configure Wave Staff. (Wave Staff has not been configured) DOK = Data Ok, Received configuration string with correct check sum Monitoring the sampled data: The sampled data may be monitored via the RS232 serial port if the configuration control byte is set to enable the RS232 port: Example with Air Temperature enabled: 2345 +0416 2345 +0416 : : 2345 +0416 Example without Air Temperature enabled: 2345 2345 : 2345 Sync Mode Operation: In Sync Mode the unit will transmit a dot when ready to receive a sample command. The Sample Commands may be either g or any two characters other than g. 1. The g command returns the sensor data first, a line end character second and a dot to indicate it s ready for the next sample command third. 2. The any character command initiates a sample with any key. Then a > is returned indicating the sampled data is ready. A second character must now be sent to receive the sampled data. 4

Configuring the Wave Staff III: To Configure the Wave Staff a 44 comma separated 2 ASCII character string must be sent to the Wave Staff. Configuration String, Comma Delimited, Transmitted via RS232 serial port to Wave Staff Offset Length & Type Name Range and Description 00h 3 ASCII bytes Sensor Type 01, = Wave Staff version D 03h 3 ASCII bytes Staff length Counter 00, to FF, Hex value determined by Staff Length, See Table below Staff Length Configuration values 06h 3 ASCII bytes Staff length Prescaler XX, Hex value determined by Staff Length, See Table below Staff Length Configuration values 09h 6 ASCII bytes Gain Correction 00,00, to FF,FF, 16 bit unsigned Hex value, Gain correction value 1000 Hex = 0% 119A Hex = +10% 0E66 Hex = -10% 80,00, to 7F,FF, 16bit Sign 2s comp. Hex value, Zero correction value 00,00, = 0 % 00,05, = +5 counts FF,FB = 5 0Fh 6 ASCII bytes Zero Correction counts, Correction is 1 for 1 15h 3 ASCII bytes Sample Frequency 02, or 05, or 0A, or 14, or 1E, Hex. Selects Sample Frequency 02, or 05, or 10, or 20, or 30 Hz 18h 24 ASCII bytes (reserved) 00,00,00,00,00,00,00,00, = Reserved space, 8 comma delimited 3 ASCII char. 33h 27 ASCII bytes (reserved) 00,00,00,00,00,00,00,00,00, = Reserved space, 9 comma delimited 3 ASCII char. 4Eh 51 ASCII Bytes (reserved) 00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00, = Reserved space, 17 comma delimited 3 ASCII char. 7Eh 3 ASCII bytes Control Byte See Control Byte Table below 81h 3 ASCII bytes Check Sum 00, to FF, Value is the sum of the Hex values in offset 00h to 81h (Note: Treat all Dec. values as Hex Values) 5

Staff Length Configuration values for Coax Cable Staff Staff type Staff Length Meters Staff Length Counter Hex Value at offset address 03h Staff Length Prescaler Hex Value at offset address 06h Coax Cable Staff 0.25 C7 2 Coax Cable Staff 0.5 C7 1 Coax Cable Staff 1 C7 0 Coax Cable Staff 1.5 85 0 Coax Cable Staff 2 C7 8 Coax Cable Staff 2.5 9F 8 Coax Cable Staff 3 85 8 Coax Cable Staff 3.5 72 8 Coax Cable Staff 4 64 8 Coax Cable Staff 4.5 58 8 Coax Cable Staff 5 50 8 Coax Cable Staff 5.5 48 8 Coax Cable Staff 6 42 8 Coax Cable Staff 6.5 3D 8 Coax Cable Staff 7 39 8 Coax Cable Staff 7.5 35 8 Coax Cable Staff 8 32 8 Coax Cable Staff 8.5 2F 8 Coax Cable Staff 9 2C 8 Coax Cable Staff 9.5 2A 8 Coax Cable Staff 10 28 8 Coax Cable Staff 10.5 26 8 Coax Cable Staff 11 24 8 Staff Length Configuration values for Coax Rod Staff Staff type Staff Length Meters Staff Length Counter Hex Value at offset address 03h Staff Length Prescaler Hex Value at offset address 06h Coax Rod Staff 0.5 A3 2 Coax Rod Staff 1 A3 1 Coax Rod Staff 1.5 6D 1 Coax Rod Staff 2 A3 0 Sample 44 comma separated 2 ASCII character Configuring string: Example: 3 meter Staff, 20Hz sample rate, free run mode, air water temp enabled, RS232 enabled, ASCII data, High Low Alarm outputs enabled. 01,3E,08,10,8C,FF,67,14,00,00,00,00,00,00,00,00,03,0B,B8,0B,54,03,E8,04,4C,00,00,00,00,00,00, 00,00,00,00,00,00,00,00,00,00,00,3A,7F 6

Control Byte 7 0 = N.A. 6 5 4 1 = Sync mode: sensor waits for command via RS232 0 = Free Run: Sensor samples at selected sample frequency 1 = Enable analog output 0-5V 0 = Disable analog output 1 = Air Temp. enabled 0 = Air Temp disabled 3 0 = N.A. 2 0 = 9600 baud, default 1 0 1 = RS232 output enabled 0 = RS232 output disabled 1 = BIN Data format 0 = ASCII Data format. 7