Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Similar documents
Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Micro duct Cable with HDPE Sheath for Installation by Blowing

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

TECHNICAL SPECIFICATION

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

Revision No. 4 Page No. Page 1 of 7

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

TENDER SUMMARY. Tender Title:

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

SPECIFICATION. Optical Fiber Cable

1. General. 1. Scope. 2. Quality Assurance

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Number of Fiber 6 Core 12 Core. Part Number

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

Detailed Specifications & Technical Data

Number of Fiber 6 Core 12 Core 24 Core 48 Core

LD Series High Performance Loose Tube Fiberoptic Cables

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Ø 1000 * 588 mm 50 kg

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

OPTICAL FIBRE CABLE NETWORK 2004/1

HERA RETICULATION FIBRE CABLE PRODUCT REQUIREMENTS

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

FREEDM Loose Tube Interlocking Armored Cables

SPECIFICATION. Spec No : VSS-1402-CS603B

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Mining and Petrochemical Fiber Optic Cables

TECHNICAL SPECIFICATION

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

Material Description Quantity UOM

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

ETSI ES V1.1.1 ( )

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

for FOSTEC INC. 1/ 15

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Product Catalogue. Fibre Optic Cable

Empowering businesses through innovative network solutions.

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

OPTICAL CABLE FIBER-LAN INDOOR

SOLO ADSS Short-Span Cables, Fibers

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Table of Contents. Open Matrix System (OMS) 1-2

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

How to Speak Fiber Geek Article 4: Single-Mode Optical Fiber Geometries

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Cable installation guidelines

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

DOME OPTIC SPLICE CLOSURE

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

Industry solutions: Broadcast

INDUSTRY SOLUTIONS: MINING

PM Couplers (Polarization Maintaining Couplers)

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

PRO SERIES FIBRE-150M

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

HITRONIC Optical Transmission Cable

Mar11 Rev E

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

SECTION 4 TABLE OF CONTENTS

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

The World Of Professional Fiber Optics. safe flexible reliable

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

Instrumentation & copper telecom cables

Content. 1.4 Fiber Cable Assembly

We design, build, and manage web-scale networks for the needs of tomorrow. System Integration SERVICES

ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

Public Works Division Lighting District Fiber Optic Specifications April 2009

LIIN-25 FO Pigtail FC (0.9mm)

FIBRE OPTIC CABLE SOLUTIONS

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

The advantages of using reduced coating diameter optical fibers (200µm) in ADSS cables for deployment in FTTx networks

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

Transcription:

Spec No.: ZTT 45012 Revision: 2 Date: Oct 3, 2014 TECHNICAL SPECIFICATION Optical Fiber Cable (Reference: NBR 14566) Designer Senior Technical Manager Approver Chief Technical Engineer Jiangsu Zhongtian Technology Co., Ltd. No. 5 Zhongtian Road, NEATA, Nantong City, Jiangsu province, China Tel: +86-513-8919 1138 Fax: +86-513- 8359 9670

1. General 1.1 Scope This listed specification covers the design requirements and performance standard for the supply of optical fiber cable in the industry. It also includes ZTT premium designed cable with optical, mechanical and geometrical characteristics. Cable type CABO FO CFOA-SM&NZD-DD-TS-144 Application Duct installation cable 1.2 Cable Description ZTT cable possesses high tensile strength and flexibility in compact cable sizes. At the same time, it provides excellent optical transmission and physical performance. 1.3 Quality Excellent quality control is achieved through intense in-house quality check and stringent audit acceptance by ISO 9001. 1.4 Reliability Initial and periodic product qualification tests for performance and durability are performed rigorously to ensure product reliability. 1.5 Reference The cable which ZTT offered are designed, manufactured and tested according to international standards as follows: IEC 60793-1 IEC 60793-2 IEC 60794-3-10 ITU-T G.650 ITU-T G.652 ITU-T G.655 Optical fiber Part 1: Generic specifications Optical fiber Part 2: Product specifications Outdoor cables- family specification for duct and directly buried optical telecommunication cable Definition and test methods for the relevant parameters of single-mode fibers Characteristics of a single-mode optical fiber and cable Characteristics of a non-zero dispersion-shifted single-mode optical fiber and cable www.zttcable.com ALL Rights Reserved Copyright 2014 page 1 of 11

2. Optical Fiber The optical fiber is made of high pure silica and germanium doped silica. UV curable acrylate material is applied over fiber cladding as optical fiber primary protective coating. The detail data of optical fiber performance are shown in the following table. Optical fiber uses special spun device to successfully control the value of PMD to ensure stability during cabling. G.652D Fiber in Cable Category Description Before cabling After cabling Attenuation @1310 nm 0.34 db/km <0.36 db/km Attenuation @1383 nm 0.34 db/km <0.36 db/km Attenuation @1550 nm 0.20 db/km <0.22 db/km Attenuation @1625 nm 0.22 db/km <0.24 db/km Attenuation Uniformity @1310nm @1550nm <0.08dB/km <0.05dB/km Point Discontinuity @1550 nm 0.05dB Zero Dispersion Wavelength 1300~1323 nm Optical Zero Dispersion Slope 0.092 ps/nm 2 km Dispersion @1285~1330nm 3.5 ps/nm km @1525~1575nm PMD (Max. Individual Value) Cable Cutoff Wavelength (λcc) Macro bending Loss (100 turns; Ф50 mm) @1550 nm (100 turns; Ф50 mm) @1625 nm 18 ps/nm km 0.2 ps/ km 1270nm 0.05 db 0.10 db Mode Field Diameter @1310 nm 9.3±0.5μm @1550 nm 10.5±0.8μm Cladding Diameter 125 ±2μm Dimensional Core / Clad Concentricity <0.8μm Cladding Non-Circularity <2% Coating Diameter 245 ±10μm Mechanical Coating-Cladding Concentricity Peak Coating stripping force Average Coating stripping force <12μm 1.5 N <F<10 N 1 N <F<5 N www.zttcable.com ALL Rights Reserved Copyright 2014 page 2 of 11

G.655 Fiber in Cable Category Description Before cabling After cabling 1550nm 0.22 db/km 0.25 db/km Attenuation 1625nm 0.24 db/km 0.30 db/km Attenuation Uniformity @1550±20nm 0.05dB/km Point Discontinuity @1550±20nm 0.05dB Optical Cable Cutoff Wavelength (λcc) <1450 nm Mode-Field Diameter @1550nm (8~11)±10%μm Dispersion Value 1530nm 1565nm 0.5ps/(nm.km) 10ps/(nm.km) PMD (Max Individual Value) 0.5ps/ km Cladding Diameter 125.0±2μm Dimensional Mode field / Clad Concentricity <0.8μm Cladding Non-Circularity <2% Coating-Cladding Concentricity <12μm Mechanical External Coating stripping force 1.5N <F<5 N www.zttcable.com ALL Rights Reserved Copyright 2014 page 3 of 11

3. CABLE STRUCTURE 3.1 Cable Type: CABO FO CFOA-SM&NZD-DD-TS-144(PE outer sheath) Construction: 1. Outer sheath (PE) Picture is only for reference Technical Characteristics The unique fiber excess length control method provides the cable with excellent mechanical and environmental properties Multiple water blocking material filling provides dual water blocking function 2. Loose tube, fiber and water blocking yarn 3. Water blocking tape 4. CSM (FRP with coating) 5. Water blocking yarns 6. ID tape( interval max. 50cm) 7. Strength member 8. Rip cords(1) Dimension and Properties Fiber count 72 B1D+72B4 No of loose tube / filler No. 12/0 Fiber No. per tube 12 6 G.652D+6 G.655 fibers in each tube Outer sheath thickness PE Black 1.4mm Physical Cable OD 19.0mm Mechanical Cable weight Operation temperature range Installation temperature range Transport and storage temperature range Max. tensile load Crush resistance Minimal installation bending radius Minimal operation bending radius 190kg/km±15% -20 deg C to + 65 deg C -15 deg C to + 60 deg C -20 deg C to + 65 deg C (2 times cable weight per KM), min.2000n (1 times cable weight per KM), min.1000n/10cm and max.2200n/10cm 20OD 10OD 1 2 3 4 5 6 7 8 Color code scheme: Fiber color Green Yellow White Blue Red Violet Brown Pink Black Grey Orange Aqua Tube color Green Yellow White White White White White White White White White White Note: each tube with 12 fibers with 6 fibers G.652D and 6 fibers G.655. G.652D fiber color: Green, Yellow, White, Blue, Red and Violet. G.655 fibers with other 6 colors. www.zttcable.com ALL Rights Reserved Copyright 2014 page 4 of 11

3.2 Cable Type: CABO FO CFOA-SM&NZD-DD-TS-144(FR-PE outer sheath) Construction: 1. Outer sheath (FR-PE) Picture is only for reference Technical Characteristics The unique fiber excess length control method provides the cable with excellent mechanical and environmental properties Multiple water blocking material filling provides dual water blocking function 2. Loose tube, fiber and water blocking yarn 3. Water blocking tape 4. CSM (FRP with coating) 5. Water blocking yarns 6. ID tape( interval max. 50cm) 7. Strength member 8. Rip cords(1) Dimension and Properties Fiber count 72 B1D+72B4 No of loose tube / filler No. 12/0 Fiber No. per tube 12 6 G.652D+6 G.655 fibers in each tube Outer sheath thickness FR-PE Black 1.4mm Physical Cable OD 19.0mm Mechanical Cable weight Operation temperature range Installation temperature range Transport and storage temperature range Max. tensile load Crush resistance Minimal installation bending radius Minimal operation bending radius 220kg/km±15% -20 deg C to + 65 deg C -15 deg C to + 60 deg C -20 deg C to + 65 deg C (2 times cable weight per KM), min.2000n (1 times cable weight per KM), min.1000n/10cm and max.2200n/10cm 20OD 10OD 1 2 3 4 5 6 7 8 Color code scheme: Fiber color Green Yellow White Blue Red Violet Brown Pink Black Grey Orange Aqua Tube color Green Yellow White White White White White White White White White White Note: each tube with 12 fibers with 6 fibers G.652D and 6 fibers G.655. G.652D fiber color: Green, Yellow, White, Blue, Red and Violet. G.655 fibers with other 6 colors. www.zttcable.com ALL Rights Reserved Copyright 2014 page 5 of 11

3.3 Cable Type: CABO FO CFOA-SM&NZD-DD-TS-144(LSZH outer sheath) Construction: 1. Outer sheath (LSZH) Picture is only for reference Technical Characteristics The unique fiber excess length control method provides the cable with excellent mechanical and environmental properties Multiple water blocking material filling provides dual water blocking function 2. Loose tube, fiber and water blocking yarn 3. Water blocking tape 4. CSM (FRP with coating) 5. Water blocking yarns 6. ID tape( interval max. 50cm) 7. Strength member 8. Rip cords(1) Dimension and Properties Fiber count 72 B1D+72B4 No of loose tube / filler No. 12/0 Fiber No. per tube 12 6 G.652D+6 G.655 fibers in each tube Outer sheath thickness LSZH Black 1.4mm Physical Cable OD 19.0mm Mechanical Cable weight Operation temperature range Installation temperature range Transport and storage temperature range Max. tensile load Crush resistance Minimal installation bending radius Minimal operation bending radius 235kg/km±15% -20 deg C to + 65 deg C -15 deg C to + 60 deg C -20 deg C to + 65 deg C (2 times cable weight per KM), min.2000n (1 times cable weight per KM), min.1000n/10cm and max.2200n/10cm 20OD 10OD 1 2 3 4 5 6 7 8 Color code scheme: Fiber color Green Yellow White Blue Red Violet Brown Pink Black Grey Orange Aqua Tube color Green Yellow White White White White White White White White White White Note: each tube with 12 fibers with 6 fibers G.652D and 6 fibers G.655. G.652D fiber color: Green, Yellow, White, Blue, Red and Violet. G.655 fibers with other 6 colors. www.zttcable.com ALL Rights Reserved Copyright 2014 page 6 of 11

4. Test Requirements Approved by various professional optical and communication product institution, ZTT also conduct various in-house testing in its own Laboratory and Test Center. ZTT also conduct test with special arrangement with the Chinese Government Ministry of Quality Supervision & Inspection Center of Optical Communication Products (QSICO). ZTT possess the technology to keep its fiber attenuation loss within Industry Standards. The cable is in accordance with applicable standard of cable and requirement of customer. The following test items are carried out according to corresponding reference. Routine tests of optical fiber Mode field diameter IEC 60793-1-45 Core/clad concentricity IEC 60793-1-20 Cladding diameter IEC 60793-1-20 Cladding non-circularity IEC 60793-1-20 Attenuation coefficient IEC 60793-1-40 Chromatic dispersion IEC 60793-1-42 Cable cut-off wavelength IEC 60793-1-44 www.zttcable.com ALL Rights Reserved Copyright 2014 page 7 of 11

Test: 4.1 Tension Loading Test Sample length Load Duration time s IEC 60794-1-2 E1 No less than 25 meters Max. tension load 1 minute Fiber strain: 0.20%; Residual fiber strain: 0.05% Additional attenuation 0.05dB/km @1550nm Attenuation discontinuity 0.05dB @1550nm After test, the load be increased up to (3 times cable weight per KM,min.3000N) the fiber strain shall not be higher than 0.6% 4.2 Crush/Compression Test Load Duration time IEC 60794-1-2 E3 Crush load 2 minutes Test number 3 s Additional attenuation 0.05dB/km @1550nm 4.3 Impact Resistance Test Impact energy Radius IEC 60794-1-2 E4 9J (height 15cm, weight 6kg) for 14.0<D 16.6mm 12.5mm Impact points 5 Impact number 5 4.4 Repeated Bending Test Bending radius IEC 60794-1-2 E6 6 X diameter of cable Cycles 25 cycles (load: 20N) Additional attenuation 0.05dB/km @1550nm www.zttcable.com ALL Rights Reserved Copyright 2014 page 8 of 11

4.5 Flexing Test Bending radius Cycles 4.6 Torsion/Twist Test IEC 60794-1-2 E8 280mm 50 cycles Additional attenuation 0.05dB/km @1550nm IEC 60794-1-2 E7 Sample length 20cm Angles ±90 degree cycles 10 Additional attenuation 0.05dB/km @1550nm 4.7 Bend Test Mandrel radius IEC 60794-1-2 E11B 6 X diameter of cable Turn number 5 Number of cycles 1 Additional attenuation 0.05dB/km @1550nm 4.8 Temperature cycling Test IEC 60794-1-2 F1 Temperature step 48 hours at -20 ; 48 hours at 65 Cycles 4 Additional attenuation 0.05dB/km @1550nm 4.9Water penetration Test Height of water column Sample length Test time IEC 60794-1-2 F5 1m 3m 24 hrs No water leakage from the opposite of the sample www.zttcable.com ALL Rights Reserved Copyright 2014 page 9 of 11

4.10 Abrasion Test Steel corner Cycles Load Movement length IEC 60794-1-2 E2 Radius 1~2mm 30 cycles 40N 60cm Sheath decrease depth 1mm 4.11 Vibration Test NBR 13990 Cable length Load Amplitude Cycles 4m One time of cable weight ±0.75mm 360 cycles (each cycle includes 10Hz to 55Hz for 30s and 10Hz for 30s) Additional attenuation 0.05dB/km @1550nm www.zttcable.com ALL Rights Reserved Copyright 2014 page 10 of 11

5. Packing and Drum 5.1 ZTT cables are packed in carton, coiled on Bakelite & wooden drum. During transportation, right tools should be used to avoid damaging the package and to handle with ease. Cables should be protected from moisture; kept away from high temperature and fire sparks; protected from over bending and crushing; protected from mechanical stress and damage. Wooden strip seal Wooden flange Cable fixing point Inner tub Axle hole Cable trough 5.2 The color of cable marking is white. (The printing shall be carried out at interval of 1 meter on the outer sheath of cable) The inner end of cable is then sealed with heat shrinkable end cap to prevent ingress of water and is made available for testing. The outer end of cable is equipped with heat shrinkable end cap. Outer sheath marking legend can be changed according to user s requests. 5.3 Outdoor cable packing Bakelite & wooden drum Strong wooden batten protection www.zttcable.com ALL Rights Reserved Copyright 2014 page 11 of 11