Model Number Structure

Similar documents
Model Number Structure

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Multifunction Digital Timer

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

K3MA Series. Digital Panel Meters K3MA-L K3MA-F K3MA-J. Frequency/Rate Meter. Process Meter. Temperature Meter INTRODUCTION

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

K3MA Series Digital Panel Meter USER MANUAL

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Self--powered Time Counter

Accessories (Order Separately)

H8GN. Model Number Structure. Ordering Information. Preset Counter/Timer (48 24) Model Number Legend. List of Models

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Weighing Meter. Ordering Information. Highly Functional Weighing Meter with Easy-to-read LED. Base Units

02/11/2015

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

K3NX Process Meter OPERATION MANUAL

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Self-powered Totalizer

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Type Contact form Model

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Frequency/Rate Meter

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Self-powered Totalizer New H7E

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

Features. Digital Time Switch H5S. Easier and More Convenient to Use

Electronic converter for level transmitters MT03L Instructions manual

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Solid-State Digital Timer

USER S MANUAL. FX2N-8AD Analog input block

Operating Manual RISH OPTIMA VAF

Input type NPN/Voltage pulse PNP 240 VAC

Ordering Information. Self-Powered Tachometer H7ER. Subminiature Tachometers With Improved Appearance and Features. H Large display with 8.

Gamma instabus. Technical product information

Process Transmitter RMA 422

USB-TG124A Tracking Generator User Manual

Indoor Linear 80W Driver SI-C215280N2KR

True RMS AC/DC Mini Clamp Meter

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Digital Time Switch H5S. Features. Easier and More Convenient to Use

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Magnecraft Power Relays

Photoelectric Sensors E3F2

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Standard signal metering in wall-mounting case

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

GC30 Digital Differential Pressure Gauge Operation Manual

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

LONWORKS Fibre Optic Converter

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

263 Series LED Bargraph Indicator and Controllers

LAUREL ELECTRONICS, INC.

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Ordering details. Approval. Classification

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

EZ-LIGHT K30L Series With Independent Push Button Contact

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

Datasheet - SRB301LC 24VAC/DC

WLS27 Multicolor LED Strip Light with EZ-STATUS

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

Specifications. Reference Documentation. Performance Conditions

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Absolute Rotary Encoder E6CP

Preset counters, electronic

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

Model /29S RF Splitter

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

SQM40/41 Actuators for air and gas dampers

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

Electronic M.O.P Card. Instruction Manual Model D

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Transcription:

Process Meter CSM DS_E_11_1 Highly Visible LCD Display with 2-color (Red and Green) LEDs Multi-range DC voltage/current input. Front-panel key operation for easy setting. Average processing function suppresses flicker. Scaling, front-panel forced-zero, zero-limit functions. Easy confirmation of max/min display. Short 80-mm depth (measured from edge of face plate). Finger protective cover (standard equipment) guards against electric shock. Water- and dust-proof NEMA4X (IP66 equivalent) front panel. Recognized to U.S. and Canadian requirements under the Component Recognition Program of UL. CE marking. Refer to Safety Precautions for All Digital Panel Meters. For the most recent information on models that have been certified for safety standards, refer to your OMR website. Model Number Structure Model Number Legend -@ 1 2 3 1. Input Type J: DC voltage/current 2. Comparative Output Model None: No output A2: 2 relay contact outputs (SPST-NO) Ordering Information 3. Supply Voltage 100-240VAC: 100 to 240 VAC 24VAC/VDC: 24 VAC/VDC List of Models Input type Supply voltage Comparative Output Model Model DC voltage/current 100 to 240 VAC None * 100-240VAC 2 relay contact outputs (SPST-NO) -A2 100-240VAC 24 VAC/VDC None * 24VAC/VDC 2 relay contact outputs (SPST-NO) -A2 24VAC/VDC * Changing the display color based on comparison with a reference is not possible. 1

Accessories (Order Separately) Name Shape Model Splash-proof Soft Cover K32-49SC Hard Cover K32-49HC Watertight Cover Y92A-49N Rubber Packing K32-P1 Note: Rubber packing is provided with the Controller. Specifications Ratings Model 100-240VAC, -A2 100-240VAC 24VAC/VDC, -A2 24VAC/VDC Supply voltage 100 to 240 VAC 24 VAC/VDC Operating voltage range Power consumption (under maximum load) Insulation resistance Dielectric strength 85% to 110% of the rated supply voltage 6 VA max. 4.5 VA max. (24 VAC) 4.5 W max. (24 VDC) 20 MΩ min. (at 500 VDC) between external terminal and case. Insulation provided between inputs, outputs, and power supply. 2,000 VAC for 1 min between external terminal and case. Insulation provided between inputs, outputs, and power supply. Noise immunity ±1,500 V on power supply terminals in normal or common mode. ±1 μs, or 100 ns for square-wave noise with 1 ns. Vibration resistance Vibration: 10 to 55 Hz, Acceleration: 50 m/s 2 5 min each in X, Y, and Z directions for 10 sweeps. Shock resistance ±480 V on power supply terminals in normal mode. ±1,500 V in common mode. ±1 μs, or 100 ns for square-wave noise with 1 ns. 150 m/s 2 (100 m/s 2 for relay contact outputs) 3 times each on 3 axes, 6 directions. Ambient temperature Operating: 10 C to 55 C (with no condensation or icing) Storage: 25 C to 65 C (with no condensation or icing) Ambient humidity Operating: 25% to 85% (with no condensation) Approved safety standards UL61010-1, CSA C22.2 No.61010-1-04, conforms to EN61010-1 (Pollution degree 2/overvoltage category II) Conforms to VDE0106/P100 (finger protection) EMC (EMI) EN61326+A1 Industry Emission Enclosure: CISPR 11 Group 1 class A: CISRP16-1/-2 Emission AC Mains: CISPR 11 Group 1 class A: CISRP16-1/-2 (EMS) EN61326+A1 Industry Immunity ESD: EN61000-4-2: 4 kv contact discharge 8 kv air discharge Immunity RF-interference: EN61000-4-3: 10 V/m (amplitude-modulated, 80 MHz to 1 GHz) Electrical Fast Transient Noise: EN61000-4-4: 2 kv (power line) Immunity Burst Noise: 1 kv line to line (I/O signal line) Immunity Surge: EN61000-4-5: 1 kv (power line) 2 kv line to ground (power line) Weight Immunity Conducted Disturbance: EN61000-4-6: 3 V (0.15 to 80 MHz) Immunity Voltage Dip/Interrupting: EN61000-4-11: 0.5 cycle, 0, 180, 100% (rated voltage) Approx. 200 g 2

Characteristics Measuring Ranges Process Voltage/Current Inputs Input/Output Ratings Relay Contact Output Input signal DC voltage/current (0 to 20 ma, 4 to 20 ma, 0 to 5 V, 1 to 5 V, ±5 V, ±10 V) A/D conversion Double integral method Sampling period 250 ms Display refresh period Sampling period (sampling times multiplied by number of measurements for averaging if average processing is selected.) Max. displayed digits 5 digits (19999 to 99999) Display 7-segment digital display, Character height: 14.2 mm Polarity display is displayed automatically with a negative input signal. Zero display Leading zeros are not displayed. Scaling function Programmable with front-panel key inputs (range of display: 19999 to 99999). The decimal point position can be set as desired. Hold function Max. hold (maximum ), Min. hold (minimum ) Hysteresis setting Programmable with front-panel key inputs (0001 to 9999). Other functions Forced-zero (with front-panel key) Zero-limit Scaling teach function Display color change (green (red), green, red (green), red) OUT type change (upper limit, lower limit, upper/lower limit) Average processing (simple average) Output Relays: 2 SPST-NO Delay in comparative outputs 750 ms max. Degree of protection Front panel: NEMA4X for indoor use (equivalent to IP66) Rear case: IEC standard IP20 Terminals: IEC standard IP00 + finger protection (VDE0106/100) Memory protection Non-volatile memory (EEPROM) (possible to rewrite 100,000 times) Input Measuring range Measuring accuracy Input impedance Displayable range DC voltage 1.000 to 5.000 V ±0.1% FS ±1 digit max. 1 MΩ min. 19999 to 99999 0.000 to 5.000 V 5.000 to 5.000 V (at 23±3 C) ±0.1% FS ±1 digit max. (with scaling function) 10.00 to 10.00 V (at 23±5 C) DC current 4.00 to 20.00 ma/ 0.00 to 20.00 ma ±0.1% FS ±1 digit max. (at 23±3 C) 45 Ω Item Resistive load (cosφ = 1) Inductive load (cosφ = 0.4, L/R=7 ms) Rated load (UL ratings) 5 A at 250 VAC, 5 A at 30 VDC 1.5 A at 250 VAC, 1.5 A at 30 VDC Max. contact voltage 250 VAC, 150 VDC Max. switching capacity 1,250 VA, 150 W 250 VA, 30 W Min. permissible load (P level, reference ) 10 ma at 5 VDC Mechanical life 5,000,000 times min. (at a switching frequency of 1,200 times/min) Electrical life 100,000 times min. (at a rated load switching frequency of 10 times/min) (at an ambient temperature of 20 C) 3

Connections Terminal Arrangement Power supply Output terminals Input terminals 100- to 240-VAC type or 24-VAC/ VDC type (No polarity for 24-VDC connection.) A1 A2 Models with comparative output E1 E2 E3 E4 Voltage input E5 COM E6 E4 COM E5 Current input E6 For voltage input For current input A1 - A2 E4 E1, E6 - E5, E2 - E3 Terminal No. Name Description Operation power Connects the operation power supply. Analog input Connects the voltage or current analog input. Outputs Outputs the relay outputs. Block Diagram Input Input circuit Key Microcomputer Display EEPROM Output circuit X Contact output (See note.) 5 V 12 V Constant voltage circuit Power supply circuit Note: Relay output models only. Input Circuits Analog Input (DC Voltage/Current) Voltage input 4 A To A/D Current input 6 To A/D COM 5 B A+B=1 MΩ COM 5 45 Ω 4

Operation Main Functions Input Types and Ranges Input type (setting parameter) Function Input range (setting parameters) Setting range Input range (in-t) Selects DC voltage/current signal 0 to 20 ma (0-20) Displayable from 19999 to 99999 input 4 to 20 ma (4-20) with scaling function. The position of the decimal point 0 to 5 V (0-5) can be set as desired. 1 to 5 V (1-5) ±5 V (5) ±10 V (10) Note: The initial for the input range is 4 to 20 ma (4-20). Scaling Analog (Process) Inputs The converts input signals into desired physical s. INPUT2: Any input DISPLAY2: Displayed corresponding to INPUT2 INPUT1: Any input DISPLAY1: Displayed corresponding to INPUT1 When DISPLAY1 is set for INPUT1, and DISPLAY2 is set for INPUT2, a line will be displayed joining the two points. (Raise shift, reverse scaling, plus/minus display, etc., can be adjusted as desired.) Parameter Setting Meaning Parameter Setting Meaning inp.1-19999 to 99999 Input for dsp.1 dp %.%%%% Display four digits after decimal point dsp.1-19999 to 99999 Input for inp.1 %%.%%% Display three digits after decimal point inp.2-19999 to 99999 Input for dsp.2 %%%.%% Display two digits after decimal point dsp.2-19999 to 99999 Input for inp.2 %%%%.% Display one digit after decimal point %%%%% No decimal point Display DISPLAY 2 ( ) Display DISPLAY 1 ( ) Reverse scaling also possible. The decimal point can be optionally displayed. When displaying the decimal point, consider the number of digits to follow the decimal point prior to setting the scaling display. DISPLAY 1 ( ) DISPLAY 2 ( ) INPUT 1 INPUT 2 Input ( ) ( ) Teaching with actual s is possible. INPUT 1 INPUT 2 ( ) ( ) Input Reverse scaling, where the display decreases as the input increases, is also possible. Instead of setting by inputting with the Up Key and Shift Key, current s can be input as scaling input s for teaching. This is useful for making settings while checking the operation status of the. 5

Convenient Functions Scaling Teach The parameters (inp.1, inp.2) for the s initial setting level can be set using actual input s with the teaching function. After displaying the parameters, the actual input settings can be made with the following operation. Teaching mode Monitor mode T flashes. Use to shift to the next parameter without registering. T lights to indicate that the parameter is valid for teaching. Use to register and shift to monitor mode. Normal change T turns. Next parameter OUT Types (Comparative Output Models Only) OUT 1 and OUT 2 can be set to operate in one of the three following modes in accordance with the compared s: Upper limit (High Acting): The output is turned when the measurement is greater than its set. Lower limit (Low Acting): The output is turned when the measurement is less than its set. Upper and lower limits (Outside Band Acting): An upper limit (H set ) and lower limit (L set ) can be set independently. The output is turned when the measurement is greater than upper-limit set or less than the lower-limit set. Upper Limit (High Acting) Lower Limit (Low Acting) Upper and Lower Limits (Outside Band Acting) /2 Measurement Hysteresis Measurement /2 Hysteresis /2 upper-limit Measurement /2 lower-limit Hysteresis Hysteresis Output Output Output The three types of output operations shown above can be combined as desired. The following are examples of possible combinations. Upper Limit 2-stage Output Threshold Output Combination of Upper Limit and Upper/Lower Limits Measurement upper-limit upper-limit lower-limit lower-limit Measurement Upper-limit Measurement Lower-limit 6

Parameter Initialization This function returns all of the parameters to their initial s. Parameter Setting Meaning init off --- on Initializes all parameters. Use this to reset the after returning it to its factory-set condition. Average Processing Changing the Display Color The color of the displayed can be set to either red or green. For comparative output models (-A2), the display color can be set to change from green to red, or from red to green, according to the status of the comparison criterion. Green 100.05 Red 113.36 Average processing stabilizes displayed s to minimize flicker by averaging the fluctuating input signals. Average processing can be performed for the measurement s in either of four steps (, 2 times, 4 times, or 8 times). 8.781 Red Display Auto-return Time This function automatically returns the display to the operation level s current if no keys are pressed for a preset time (called the display auto-return time). This is useful for ignoring rapid fluctuations, e.g., eliminating spike noise. Hysteresis (Comparative Output Models Only) The hysteresis of comparative outputs can be set to prevent chattering in the output when the measurement fluctuates finely near the OUT. Move-to-Protect-Level Time The time required to shift to the protect level can be set as desired. Forced-zero Function It is possible to shift from a to the zero point with one touch of the Up Key on the front panel (for example, when adjusting reference s). Upper limit (high acting) Set Hysteresis MAX/MIN LEVEL SHIFT UP Measurement Output Zero-limit Function The zero-limit function changes any below the set to zero. This is useful when you want to change negative s to zero rather than display them, or when you want to make the display in the smallest part of the input range zero. Note: Used only for releasing the forced-zero with the Protect menu. MAX/MIN Display The maximum and minimum measurement (display) s from the time the power is turned until the current time can be stored and displayed. This is useful, for example, when measuring the maximum. Current MAX/MIN MAX/MIN LEVEL SHIFT UP Parameter Setting Meaning =-lim off : No zero-limit on : Zero-limit lim-p 0 to 99 0 to 99: Zero-limit Max MAX/MIN LEVEL SHIFT UP MAX MAX/MIN Display Min MIN MAX/MIN MAX/MIN LEVEL SHIFT UP Zero-limit setting Input 7

Nomenclature 2. Operation indicators 3. Level indicator 1 2 SV Max Min 1. Main indicator Z T MAX/MIN LEVEL SHIFT UP 4. MAX/MIN key 5. Level key 6. Mode key 8. Up key 7. Shift key Name Functions 1. Main indicator Displays current s, parameters, and set s. 2. Operation 1 Lit when output 1 is. indica- 2 Lit when output 2 is. tors SV Lit when a set is being displayed or changed. Max Lit when the main indicator is showing the MAX. Min Lit when the main indicator is showing the MIN. Z Lit during the forced-zero operation. T Lit when the teaching function is operable. Blinks while the teaching function is operating. 3. Level indicator Displays the current level that the is in. (See below for details.) 4. MAX/MIN Key Used to display the MAX and MIN s when a measurement is being displayed. 5. Level Key Used to change the level. 6. Mode Key Used to allow the main indicator to indicate parameters sequentially. 7. Shift Key Used to enable a set to be changed. When changing a set, this key is used to move along the digits. 8. Up Key Used to change a set. Used to set or clear a forced-zero function when a measurement is being displayed. p Not lit s f Level indicator Level Protect Operation Initial setting Advanced-function setting Dimensions 101.2 91 Finger protective cover (provided) Main indicator character size Panel cut-out 120 min. A B C D E 14.2 mm 85 97 7.6 mm 75 min. 92 +0.5 0 96 12 1.3 48 80 44.8 45 +0.5 0 Mounting Recommended Panel Thickness 1 to 8 mm. Mount the product horizontally. The uses M3 terminals. MAX/MIN LEVEL SHIFT UP 8

Application Examples Monitoring interior tank pressure Displaying/outputting liquid level Flowrate sensor E8AA Pressure Sensor 4 to 20 ma Pa 4 to 20 ma or 0 to 10 V mm m/min Pump E4PA Ultrasonic Displacement Sensor 4 to 20 ma Tank Discharge valve Pump Flowrate Sensor Monitoring gas pressure Inspection instruments in food or pharmaceutical plants Installation 1. Insert the into the panel cut-out hole. 2. For a waterproof installation, insert the rubber gasket onto the body of the. 3. Fit the adaptor into the grooves on the left and right sides of the rear case, then push it until it contacts the panel to secure the. Monitoring liquid level in cleaning tanks Water tanks, devices using chemicals, etc. Rubber Packing K32-P1 If the rubber packing is lost or damaged, it can be ordered using the following model number: K32-P1. (Depending on the operating environment, deterioration, contraction, or hardening of the rubber packing may occur and so, in order to ensure the level of waterproofing specified in NEMA4, periodic replacement is recommended.) Note: Rubber packing is provided with the Controller. Wiring Precautions Use crimp terminals. Tighten the terminal screws to a torque of approximately 0.5 N m. To avoid the influence of noise, route signal lines and power lines separately. Wiring Use the following M3 crimp terminals. Monitoring send-out flowrate Water processing devices, etc. 5.8 mm max. Angle of View The K3MA is designed to provide the best visibility at the angles shown in the following diagram. 5.8 mm max. Unit Labels (Provided) The unit labels are not attached to the. Select the desired labels from the provided sheet. 10 30 Watertight Cover Y92A-49N Note: For scales and gauges, use the unit labels that are specified by the relevant laws or regulations. 9

Operating Procedures Operations in Run Mode Setting and Releasing a Forced Zero Setting a Forced Zero Any reference point can be easily set to zero. Displayed Forced zero input Z indicator Measured Measured after setting forced zero Press the Up Key while the measurement is being displayed. The displayed will be shifted to 0 and measurement will be continued. The Z indicator will light when a forced zero has been set. The shifted measurement after a forced zero has been set will be maintained even after power is turned. If forced-zero protection is turned in the protect level, the Up Key cannot be used to set a forced zero. Forced-zero protection is in the default settings. Releasing a Forced Zero Press the Up Key for 1 s min. to release the forced zero. The Z indicator will turn. Checking the Maximum and Minimum Values The maximum and minimum s can be displayed by pressing the MAX/MIN Key while the measurement is being displayed. The maximum and minimum s can be reset by pressing the MIN/MAX Key for 1 s min. when the maximum or minimum is displayed. Checking and Setting Comparative Set Values (for Models with the Comparative Output Function) Each time the Mode Key is pressed when the measurement, maximum, or minimum is displayed, the comparative s will be displayed in the following order: (or upper-limit, lower-limit 1), OUT 2 (or OUT 2 upper-limit, lower-limit 2). Measurement MAX MIN Measurement MAX/MIN Key upper-limit MAX lower-limit MAX/MIN Key MIN upper-limit MAX/MIN Key lower-limit Mode Key Mode Key Mode Key Mode Key Mode Key Note: When a comparative is displayed, it can be changed by pressing the Shift Key and the Up Key (when key protection is ). Levels Level refers to a grouping of parameters. The following table lists the operations that are possible in each of the levels, and the diagram tells how to move between levels. There are some parameters that are not displayed for certain models. Level name Function Measurement Protect Setting lockouts. Continue Operation Initial setting Advanced-function setting Displaying current s, setting/clearing forced-zero function, and setting OUT 1/2 s. Making initial settings of input type, scaling, output operating action, and other parameters. Setting average processing, display color settings, and other advanced-function parameters. Continue Stopped Stopped 10

Power + Time set by user (See note.) Protect level + 1 s min. Operation level 1 s min. 1 s min. -1234.5 Flashing stops if key is released. Indicates change of level. Continue to press the key for 2 s min. Initial setting level 1 s min. Advanced-function setting level Password "-0169" Note: The move-to-protect-level time can be set in the advanced-function setting level. 11

Parameters ome parameters are not displayed for certain models. he will stop measurement if the level is changed to the initial setting level or dvanced-function setting level. the input range is changed, some parameters are set to default s. Therefore, t the input range first. ettings displayed in reversed colors are defaults. Power Operation level For models with the comparative output function Current Set one of these. upper-limit lower-limit Set one of these. upper-limit lower-limit 12

Press Level Key for more than 3 s. Press Level Key for more than 1 s. Initial setting level Input type Scaling display 1 Scaling input 2 Scaling input 1 Scaling display 2 Decimal point position To change a setting, press the Shift Key make the change with the Up Key. Press Level Key for more than 1 s. / / / / Advanced-function setting level Enter password "-0169" Parameter initialization Models with the comparative output function again, and then Average processing hysteresis hysteresis Zero-limit / / / / Unit: times Zero-limit / type type Move to advancedfunction setting level Upper Limit Lower Limit Upper/Lower Limits Upper Limit Lower Limit Upper/Lower Limits When zerolimit is Zero-limit Display color change Display auto-return time Green (red) Green Red (green) Red Unit: s Move-toprotectlevel time Unit: s 13

Press Level Key + Mode Key for more than 1 s. Operation level Press Level Key + Mode Key for more than preset time. Protect level Operation/adjustment lockouts Setting level lockout Setting change lockout Forced-zero shift lockout / / / / / / Operation/Adjustment Lockouts Restricts key operations for operation level and adjustment level. Parameter Setting Operation level Current display Set display oapt 0 Allowed Allowed 1 Allowed Allowed 2 Allowed Prohibited Initial setting is 0. This cannot be displayed on models not equipped with the comparative output function. Setting Level Lockout Restricts shifting to initial setting level or advanced-function setting level. Parameter Setting Shift to initial setting level icpt 0 Allowed Allowed 1 Allowed Prohibited 2 Prohibited Prohibited Setting Change Lockout Restricts setting changes by key operation. When this lockout is set, it is no longer possible to shift to a setting change mode. However, all protect level parameters can still be changed. Forced-zero Lockout Shift to advancedfunction setting level Parameter Setting Setting change by key operation wtpt off Allowed on Prohibited Restricts the setting or release of a forced-zero by front-panel key operation. Initial Settings Press the Level Key level. If required, shift to the advanced-function setting level to set the number of measurements for averaging, hysteresis s, auto-zero limit, display color change, display auto-return time, or move-to-protect-level time. Press the Level Key operation level. Power Select the input type. Set the scaling s and specify output operating action as required. Specify set of OUT 1 and 2. for 3 s min. to move to the initial setting for less than 1 s min. to return to the Measurement starts. Parameter Setting Setting/release of forced-zero by key operation =rpt off Allowed on Prohibited 14

1 2 SV MAX/MIN LEVEL SHIFT UP Setting Example Initial Settings The settings for the following example are shown here. Example: Tank pressure display Display DISPLAY 2 ( ) 0 to 980 kpa 4 to 20 ma Pressure Sensor Max Min DISPLAY 1 ( ) -A2 24VAC/VDC Input INPUT 1 INPUT 2 ( ) ( ) Here, the pressure inside the tank is to be displayed in units of 0.1 kpa. Pressure Sensor Measuring range: 0 to 980 kpa, output 4 to 20 ma Troubleshooting 1. Set the input type to the 4 to 20 ma input range. Parameter: in-t (input type), Setting : 4-20 2. Set the display s for the corresponding input s. Set the scaling as shown below for the following correspondence: input 4 ma-->display 0.0, input 20 ma-->display 980.0 Parameter Setting inp.1 (scaling input 1) 4.00 dsp.1 (scaling display 1) 00000 inp.2 (scaling input 2) 20.00 dsp.2 (scaling display 2) 09800 dp (decimal point position) %%%%.% Note: The decimal point position here refers to the position in the number after scaling. When setting the scaling display, it is necessary to consider the number of digits to be displayed past the decimal point. When an error occurs, error details will be displayed on the main indicator. Confirm the error from the main indicator and take the appropriate countermeasures. Level Main indicator Error contents Countermeasures display Not lit e111 RAM memory error Repair is necessary. Consult your OMR sales representative. 5 e111 EEPROM memory error When this error is displayed, press the Level Key for 3 seconds, and the settings will be restored to the factory settings. If the error cannot be recovered, repair is necessary. Consult your OMR sales representative. Not lit Flashes s.err You will see this indication when turning the product the first time after purchase. This is because At the initial setting level, set the input type and other parameters according to your application. the input signal is 0 ma at that time even though the range is factory set to 4 to 20 ma. For the -A2, the relay output will be. Input error Promptly change the input voltage/current to a that falls within the measurement range. If the error cannot be recovered, repair is necessary. Consult your OMR sales representative. Not lit Flashes 99999 The scaling display exceeds 99999. Promptly change the input to a that falls within the specified range. The scaling may be inappropriate. Review the scaling at the initial setting level. Not lit Flashes -19999 The scaling display is lower than 19999. Promptly change the input to a that falls within the specified range. The scaling may be inappropriate. Review the scaling at the initial setting level. ALL DIMENSIS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 15

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMR representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMR MAKES NO WARRANTY OR REPRESENTATI, EXPRESS OR IMPLIED, ABOUT N-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMR COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTI OR COMMERCIAL LOSS IN ANY WAY CNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATI INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMR PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMR Corporation Industrial Automation Company http://www.ia.omron.com/ 2014.7 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMR Corporation 2014 All Right Reserved.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: -A2 24VAC/VDC 24VAC/VDC