TECHNICAL SPECIFICATIONS

Similar documents
SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification

INFORMATION FOR VISITING COMPANIES

DEREHAM MEMORIAL HALL

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical Specification Pavilion Dance

New Theatre Royal Lincoln Technical Information

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Main House Technical Specification

Dr JOHN GALLAGHER CONCERT CHAMBER

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Specifications Nov 2016

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Theatre Technical Specifications

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Technical Specifications

Technical Information

Technical Specification

TECHNICAL SPECIFICATIONS

Technical Specifications Updated 01/10/2017. Stage

Technical specifications Main theatre. Sound

TECHNICAL SPECIFICATIONS

Stage. Get In & Parking

HIRE AND TECHNICAL INFORMATION

Technical Specification for the Alley Theatre, Strabane

TECHNICAL SPECIFICATION

Main House Technical Specifications

UNIVERSITY CONCERT HALL. Technical Specification

The Haymarket Basingstoke Technical Specifications

Matt Dann Cultural Centre

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

Cornerstone Technical Specifications 2018 / V1

Technical Pack. Attenborough Arts Centre

Technical Specification. Updated: April 2016

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Theatre Technical Specification

MAIN THEATRE TECHNICAL SPECIFICATION

JERWOOD VANBRUGH THEATRE

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Technical Data Sheet

Technical Specification Ardhowen Theatre

Technical Specification Ver 01/16

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

Lighthouse Theatre Technical Specification

Darlington Hippodrome Technical Specification

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Latrobe Performing Arts Centre

The Georgian Theatre Royal Technical Information For Visiting Companies

Technical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Hopgood Theatre NOARLUNGA CENTRE

Technical Specification

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

2017 TECHNICAL SPECIFICATIONS

The Anvil Technical Specifications

Summary. Access and Parking

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

MAIN AUDITORIUM TECHNICAL INFORMATION

Technical Specifications

ISLAND HALL TECHNICAL INFORMATION

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

RPAC REDLANDS PERFORMING ARTS CENTRE

THE STREET THEATRE. Technical Specifications

CENTRE FOR PERFORMING ARTS

Technical Specification

Contains directions and stock hire info.

DRAÍOCHT Technical Specification: MAIN SPACE

Technical Services and Specification

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Technical Information

CHELSEA THEATRE. Technical Specifications

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Information for Incoming Companies

Derby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.

Rhodes Arts Complex Bishops Stortford. Technical Specifications

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Salisbury Arts Centre Technical Specification v Page 1 of 7

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Technical Information

Pleasance London Main House Visiting Company Information Pack May 2017

Barney Simon Theatre Technical Specifications

Hopgood Theatre NOARLUNGA CENTRE

Dugdale Centre Technical Specification

THEATRE ROYAL MARGATE Technical Specification April 2018

MAIN HOUSE TECHNICAL SPECIFICATION

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

THEATRE ROYAL MARGATE Technical Specification January 2016

Catford Broadway Theatre

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Yan Yean Theatre Technical Specifications

The Mannie Manim Technical Specifications

Monash Academy of Performing Arts

Transcription:

TECHNICAL SPECIFICATIONS Updated May 2018 Stage Dimensions Stage Rake 1:40 Proscenium 8.4m wide by 7.12m high. 27 6 by 23 4 Height from stage floor to the bottom of the 5.00m House Border 16 4 Height from stage floor to bottom of the House 4.40m tabs (out dead) 14 4 Depth to back wall 8.8m 28 10 Depth to Cyc 7.2m 23 7 Width between Fly Floors 9.6m 32 Height of Grid 10.5m 34 5 Distance from centre of Circle Bar to front of 8.40m Stage 27 6 Height of Circle Bar to front of Stage Level 3.20m 10 6

Flying System Specifications The Flying system at the Marina Theatre is a Double Purchase Counter Weight System. Lx IWB s are on Hand winch bars See Marina Theatre Hanging Plot for more information. Height from stage floor to the bottom of the House Border 5.00m 16 4 Height from stage floor to bottom of the House 4.40m tabs (out dead) 14 4 Width between Fly Floors 9.6m 32 Height of Grid 10.5m 34 5 Flying height 5.25m 17 2 Flying Bar Barrel length 8.70m 28 5 8x Counter Weight Bars (WLL 250Kg) (only 7 usable due to Cinema Screen) 10x Counter Weight Bars (WLL 227.5Kg) 4x Hand Winch Lx Bars (WLL 250Kg) (200Kg with IWB) 1x Hemp Bar (Up Stage) (WLL 70Kg) Counter Weight Bars: 2, 3, 6, 7, 11, 16, 18 Counter Weight Bars: 4, 5, 8, 9, 10, 12, 13, 14, 15, 17, Counter Weight 1 - Cinema Screen The screen cannot be moved or de-rigged

MARINA THEATRE HANGING PLOT ALL MEASUREMENTS ARE TAKEN FROM THE FRONT EDGE OF STAGE HEIGHT TO GRID 10.5M (35 FEET) FLYING HEIGHT 5.00M (16.5 FEET) BAR LENGTH 8.80M (28 FEET 10 INCHES) ITEM DIST. FROM STAGE Safety Curtain 0.90M 2 11 House Tabs 1.30M 4 3 CW 1 1.40M 4 7 HAND 1.68M 5 6 WINCH 1 CW 2 1.9M 6 3 CW 3 2.1M 6 10 CW 4 2.35M 7 8 CW 5 2.65M 8 8 CW 6 2.82M 9 3 HAND 3.1M 10 2 WINCH 2 CW 7 3.3M 10 10 CW 8 3.52M 11 6 CW 9 3.72M 12 2 CW 10 3.97M 13 0 CW 11 4.22M 13 10 HAND 4.43M 14 6 WINCH 3 CW 12 4.7M 15 5 CW 13 5M 16 5 CW 14 5.24M 17 2 CW 15 5.4M 17 8 CW 16 5.56M 18 3 HAND 6.00M 19 8 WINCH 4 CW 17 6.28M 20 7 CW 18 6.57M 21 6 Hemp Bar 6.80M 22 4 Track BLACKS Track WHITE CYC 7.1M 23 3 7.2M 23 7 FLOWN FROM SWL CONTENTS PROMPT DESK PROMPT DESK (Electric Motor) Safety Curtain (Iron) House Tabs (Out dead - 4.40m from stage floor to bottom of Tabs) Cinema Screen (Cannot be De-rigged) SR FLY FLOOR 200KG with IWB Lx 1-18 way IWB without IWB (Cannot be brailed Downstage) SR FLY FLOOR SR FLY FLOOR SR FLY FLOOR SL LX FLOOR 200KG with IWB without IWB 200KG with IWB without IWB 200KG with IWB without IWB 70KG 18 way IWB Lx 2 18 way IWB Lx 3 16 way IWB Lx 4 Full Black Tab Curtains (Fixed Height & Position) Full White Cyclorama (Fixed Height & Position)

Backstage Miscellaneous Orchestra Pit Treads from stage into audience (2 sets) Prompt Desk located Accommodates 6-7 people (Please note that when the Orchestra Pit is covered patrons sat in the circle cannot see performers who move on to it). Located in Orchestra Pit Stage Left and Stage Right (these are not in permanently) See positioning in photo below Stage Left Visual Monitoring Infra Red Camera on centre of Circle Bar feeding Prompt Corner black and white Monitor Lit Music Stands (rat stands) 12 (subject to recharge) Cans pack intercom outstations 8 Cue Lights 6 ROH call system House tabs controlled Power Supplies Wooden Rostra Stage Right: Powerlocks: Ceeform: From Prompt Desk From Prompt Desk - 1x 200 Amp 3-1x 63 Amp Single (with 80mA RCD) 13 amp sockets: - 2x Double sockets - 1x Single socket Stage Left: Ceeform: - 1x 63 Amp 3-1x 63 Amp Single - 1x 32 Amp Single - 1x 16 Amp Single 13 amp sockets: - 1x Double sockets - 1x Single socket 4 pieces 6 by 4 - by 1 Tall 4 pieces 6 by 4 - by 2 Tall 2 pieces 6 by 4 - by 3 Tall Positioning of Positioning of Stage Right Treads Stage Left Treads

Access Equipment Please be aware that the Marina Theatre follows the HSE guidelines for Tallescope usage. This means that we operate a no moving of the Tallescope whilst the basket is occupied policy. Tallescope Model 50518 1 3.9m (13 ) 5.9m (19 6 ) Large Zarges Model 41523 1 3x 12 Rung. 3.6m (11 10 ) 6.10m (20 ) Small Zarges Hailo PrfiLOT 9306-501 1 2x6 + 1x5 Rung. 1.85m (6 ) 2.85m (9 ) Extendable ladder 1 Load-In The Load-in area can accommodate two 40 foot lorries parked side by side. One lorry can load in direct onto the Dock Gantry and one lorry can load in via a short ramp up to the Dock Gantry Overnight parking of vehicles and lorries in the Load-in area may be subject to a recharge. Dock Gantry SWL 750Kg (TBC) Dock Door 2170mm wide, 4400mm high

Backstage Facilities Backstage Dressing Room Capacity Shower Facilities Ample Toilets 7x Dressing Rooms Dressing Room 1 capacity 4 people (stage left) Dressing Room 2 (wardrobe) capacity 5 people (stage left) Dressing Room 3 capacity 3 people (stage left) Dressing Room 4 capacity 3 people (stage left) Dressing Room 5 capacity 3 people (stage left) Dressing Room 7 capacity 5 people (stage right) Dressing Room 8 capacity 6 people (stage right) Catering Facilities (stage left) Show relay Towels 29 people 1x Shower cubical - Stage Left Male & Female stage Left Unisex Stage Right 5x Stage Left, 2x Stage Right Wash Basin, Mirrors, Sofa, fridge, kettle Wash Basin, Mirrors, Automatic Washing Machine, Tumble Dryer, Iron and Board, kettle Wash Basin, Mirror, kettle Wash Basin, Mirrors, Full Length Mirror Wash Basin, Mirrors, Full Length Mirror Mirrors Mirrors, Full Length Mirror 2x Microwaves, toaster, kettle, fridge, sink, draining rack All Dressing rooms (can be turned off in each dressing room) A selection of towels are available. This is subject to a recharge.

Lighting Control Lighting ETC Element Console, 60 Fader, 250 Channel. Focus Remote ELC FocusHAND-3 DMX Remote Control System (runs on frequency 433, 92 MHz) Above Stage Lighting Positions (See Marina Theatre Hanging Plot) 3x 18-way IWB and 1x 16-way IWB SWL 250Kg without IWB SWL 200Kg with IWB FOH Lighting Positions - 10 way Static Advanced Bar above Auditorium (up in ceiling) (SWL 35Kg per meter) - 19 channel Bar on Front of Circle - 2x 6-way Slip Booms up in the Circle consisting of 5x 1.2Kw Profiles and 1x 750w Source 4 a side 101x 15amp sockets on 10amp Dimming Channel 1 6 F.O.H Boom SL Circuits: Channel 7 20 F.O.H Circle Bar Channel 21 26 F.O.H Boom SR Channel 27-32 Above DSL Channel 34-65 Above MSL Channel 67-83 Above USL Channel 85 Above USL Channel 86 87 Above USR Channel 89 90 Above USR Channel 91 93 Stage Level USL & USR Channel 95 96 Stage Level USL & USR Channel 110 114 SR FOH Advanced Bar Channel 116 120 SL FOH Advanced Bar Flood - Iris 1's 1kw 7 Flood - Coda 500/1 singles compartment 500w 10 Parcan - Par 64 - CP62 40 (Limited stock of CP60 or CP61 are available) Parcan - Par 56 4 Fresnel - ADB F101 1kW 8 Fresnel - CCT Starlette F 1kW 14 Fresnel - Cantata F 1kW 3 Fresnel - Red Rebel F 1kW 2 Fresnel - Rank Strand Prelude Fresnel - 650w 16 (4 are used as Tab Warmers) PC - CCT Starlette 6 Prelude Profile - Rank Strand 28/40-650w 4 Prelude Profile - Rank Strand 16/30-650w (4x on Advanced Bar) Profile - Rank Strand Cantata 18/32 1kW (All on FOH Advanced Bar) Profile - Rank Strand Cantata 11/26 1.2kW (All on FOH Booms) Profile - ADB DS104 Profile 1.2kW (All on FOH Booms) 10 6 6 4

Lighting continued Profile ETC Source Four (Fixed 26 ) 750w 3 (Irises & B sized Gobo holders available) Rank Strand Prolife & Prelude Iris 6 Rank Strand Prolife & Prelude B size Gobo 8 Holders Scrollers - 12 Frame Whisper Colour Scrollers 6 Follow Spots - Robert Juliat Marius 1200MSR 2 (located at back corners of Circle) Lighting Gel Standard stock of Lee gels Coemar Pro Spot LX moving head 6 Futurelight SC-780 - Scans 2 20 Mirrorball with rotators 2 12 Mirrorball with rotators 1 Hazer - Unique 2 Hazer 1

Sound Digital Control Desk Analogue Control Desk FOH P.A. Subs Stalls Main Front Fills Circle Main Circle Delay Foldback Sends 4 Yamaha 01V-96 Digital Mixing Console with MLA8 8 input upgrade Card (making a total of 24 input channels) 2x stereo inputs, 4x Aux and 4x onboard effects Soundcraft Spirit F1 mixing desk. 12x channel (Including 2x Stereo Inputs) 3x Aux. 9kW HK-Audio Element system (all Processing and Delay controlled onboard from Yamaha 01V-96) 4 x (2 a side) HK Audio E210 AS Sub (1,200W each) (active) 6 x (3 a side) HK Audio e435 mid/high units (150W each) (active Fed from Subs) 2 x HK Audio il8.1 (300W each) (passive Carver pm-600 amplifier) 8 x (4 a side) HK Audio e435 mid/high units (150W each) (active) 4 x HK Audio il8.1 (300W each) (passive Amcron Geodyne II amplifier) Foldback Speakers - 4x JBL EON 15, 2x Tannoy Wildcat, 2x Bose 802 Foldback Amplifiers - 1x Carver PM900 1x Ancrom Geodyne II Foldback Processing - 2x Rane ME15 Graphic Equalizer units Microphones - 4x Shure SM 58 (Dynamic cardioid) 6x Sennheiser e835 Mics (Dynamic cardioid) 2x Crown PCC 160 boundary Microphone 12x Audio-Technica AT851Rx micro cardioid condenser boundary microphone 1 x Sennheiser E602 MKII Kick Drum / Bass Mic Handheld Radio Microphones (All running on channel 70) 1x Sennheiser ew100 - SKP100 plug on Transmitter for Hand held microphone. 1x Trantec S4.5 DTX Handheld Lapel Radio Microphones (All running on channel 70) D.I. Boxes Playback - Compressor / Limiter 1x Sennheiser ew100 - Body pack with Lapel mic 1x Trantec S4.5 LTX Body pack with Lapel Mic 1x passive EMO single channel 1x active single channel 1x active - Behringer ultra-pro DI4000 4 channel 1x Denon DN-C615 CD Player 1x Technics SL-PG380A CD Player 1x Sony MDS-Je520 MiniDisk Player 1x Klark Teknik Dn504 Quad Comp Limiter Effects Processor Headphone Amplifier Headphones 1x Yamaha SPX 900 Effects Processor 1x Alesis Microverb 4 Effects processor 1x Behringer Powerplay Pro-XL 4-Channel 3x Panasonic RP-HT265 Stereo Headphones

Softs Black serge borders 2 Black non serge borders 2 Black Serge Legs Black non serge legs White Cyc Set of Black Tabs 2 sets 1 set 1 (Fixed position at rear of stage) 2 sets (One Set in fixed position at rear of stage) Set of Red Tabs 1 set (12.2m by 4.5m) (40 by 15 ) Set of Pink Tabs 1 set (12.2m by 5.2m) (40 by 17 ) White Legs 4 legs (1m by 10m) (3 by 33 ) Pink Legs 4 legs (1m by 10m) (3 by 33 ) House tabs and border - Dark blue with a gold stripe AV Fast Fold Front Projection Screen 1 (3m x 2.25m) (10 x 7 6 ) (usage subject to recharge) Cinema Projection Barco DP2K-23B digital projector Flown Cinema Screen and Frame Counter Weight 1 (The screen cannot be moved or de-rigged) Full Dolby Digital 5.1 surround Sound 1x Icecrypt STC6000HD PVR satellite receiver Intelsat 10-02 1 W 1x Icecrypt STC6000HD PVR satellite receiver Intelsat 905 W

General 777 seats in auditorium split over two levels (766 with FOH Mixer and Follow Spot kills) Stalls capacity: 406 (minus 5 seats for FOH Mixer Kills) Circle capacity: 371 (minus 6 seats for Follow Spot kills) (3 seats per Follow Spot) Hearing Aid Induction Loop System for Circle Access for Disabled 1 Licensed Bar ( first floor ) 1 Licensed Coffee Shop ( ground floor ) 1 Hospitality room available for hire. Accommodates up to 60 people

Contacts Chief Executive Operations Manager Technical Manager Administrator Head of Marketing Marketing officer Catering Manager Box Office Supervisor Head of Young People and Outreach Emma Butler-Smith emmabutlersmith@marinatheatre.co.uk Paul Bain paulbain@marinatheatre.co.uk Karl Dunnett karldunnett@marinatheatre.co.uk Eddi Sharp eddisharp@marinatheatre.co.uk Jo Leverett joleverett@marinatheatre.co.uk marketing@marinatheatre.co.uk Jane Bain janebain@marinatheatre.co.uk marketing@marinatheatre.co.uk Angie Cull angiecull@marinatheatre.co.uk Mandy Mussett mandymussett@marinatheatre.co.uk Will Isgrove willisgrove@marinatheatre.co.uk 01502 533214 01502 533204 01502 533230 01502 533203 01502 533213 01502 533202 01502 533215 01502 533201 01502 533205 01502 533200 01502 533231 Backstage 01502 533213 01502 533203 Theatre Email Info@marinatheatre.co.uk Website www.marinatheatre.co.uk Facebook www.facebook.com/themarinatheatre Twitter @marinatheatre1 The Marina Theatre is operated by The