Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 80 channels to mix Freely assignable faders and patching Colour backlit LCD screens per fader 20 sub-group / aux busses 8 Matrix busses LCR panning Delay on inputs and outputs 8 VCA Groups Colour touch screen interface Stagebox: Soundcraft Mini Stagebox 32R 32 Analogue In 8 Analogue Out 4 AES Out Loudspeakers: FOH L Martin Audio AQ10 x 2 FOH R Martin Audio AQ10 x 2 Subs Martin Audio Blackline S18 x 2 Foldback Proel x 4 Amplifiers: QSC AUDIO PLX2402 (Tops L&R) x 1 QSC AUDIO PLX2402 (Subs) x 1 QSC AUDIO PLX2402 (Monitors) x 1 Playback: Denon DN4500 Dual CD Player x 1 8 line inputs Pre/Post selection per input per bus Soundcraft FaderGlow GEQ on every bus 4 FX busses LRC Mix busses 4 Stereo Lexicon Effects engines 8 Mute Groups Freely assignable insert loops Fully digital operation Control position: Control room at rear with elevated position behind audience Part of back row auditorium seating can be removed for touring consoles Comms: ASL Wired Intercom System. Fixed outlets located in control room (LX and sound) plus SM position (stage left). Temporary outlets can be placed on request. Mains supply Numerous 13A sockets available side of stage, SL and SR. 32A three phase socket available SL, 3m above stage level. Distro to 3 x 1P 32A available plus 2 x 15m 1P 32A extensions and 32A 1P to 6 x 13A stage box. 32A single phase socket also available in control room at rear of auditorium. Other items: Microphones, Stands, outboard equipment and various other items may be available on request and subject to availability. There may be an additional hire charge for visiting/touring companies. Re-rigging, substitutions or alterations to the configuration of the standard in-house system are subject to prior arrangement.
Projection Projector 1 XGA resolution (1024 x 768 pixels) 4:3 aspect ratio. VGA input from DSL position. HDMI input from control room. Permanently focussed onto a motorised drop down screen, which is located roughly 2m from the front edge of the stage. Well suited for presentations that include textual content. Projector 2 Sanyo PLC-XT35 (5000 ANSI lumens). XGA resolution (1024 x 768 pixels) 4:3 aspect ratio. DVI-D input from control room, with HDMI and VGA adapters available. Remote signal sender can be moved from the control room down to back row of the auditorium for when shows are operated from there. Focussed onto the white cyc at the rear of the stage. Approximately 6.5m wide image. Due to the nature of the cyc material, this projector is not ideal for intricate textual content.
Lighting Desk: Zero 88 Solution XL 96 channel faders 30 submaster faders (x 20 pages) 4 DMX universes via 5-pin XLR ports (1 universe distributed to stage) Art-Net support via Ethernet port Dimming: Zero 88 Chilli inductive dimmers x 6 (roughly 60 operable channels) 15A outlets distributed throughout the stage and FOH areas DMX outlets: DMX infrastructure (9 x 5-pin XLR outlets) distributed throughout stage area (single universe) House lights: Controlled by separate dimmers, not linkable to the main LX desk Note: House lights have a fixed 2 second dim up and 7 second dim down time, not suitable for quick audience participation uses. Up/down/preset controls located at LX, sound and SM (stage left) positions LX control position: Control room at rear with elevated position behind audience Part of back row auditorium seating can be removed for touring consoles Haze: Unique 2.1 hazer with DMX control available Intelligent fixtures: GLP Impression X4 LED wash lights x 12 Conventional fixtures: (FOH front cover) Selecon Arena 2KW fresnels x 6 Teatro 2KW profiles x 2 Selecon Pacific 650W profiles (18-24) degrees x 4 Strand T84 1KW profiles x 8 (Over stage) Strand Patt 743 1KW fresnels x 8 1KW par cans (CP62) x 12 Strand Patt 803 650W fresnels x 8 Selecon 3 way LUI cyc lights x 4 (Additional fixtures) Selecon 1200W tungsten follow spots x 2 Strand Coda asymmetric 500W floods x 5 Strand Patt 813 650W profiles x 6 Strand Patt 823 650W profiles x 5 400W UV cannons x 2 2KW DMX controlled strobe x 1 (See the plan on next page for the standard fixture layout) A fairly wide range of Lee Filters gels (saturated colours and correction filters) are kept in stock.
LX Layout Our intention is to retain the lighting rig in this configuration most of the time. However, at certain times the layout (colours and/or fixture positions) may be very different to that shown here. Maximum trim height is approximately 6m
Audience & Stage Auditorium 312 numbered seats (see seating plan below). Rear row seats can be removed in pairs to accommodate disabled guests, technical & video recording equipment, as required. Fixed raked seating (rising up from stage level). Stage area Performance area on stage is approximately 10m x 9m. No flying facilities. Proscenium opening approximately 12m wide (bordered by soft legs and a valance). Orchestra Pit 10.5m x 2.5, can accommodate 10 musicians + MD. Fully separated crossover / back passage behind stage. Venue access Scene dock doors approximately 1.8m wide and 7.6m high Double stage doors at rear, with loading area to accommodate two large vans or three cars. Free parking at rear of theatre for production crew / cast, this is shared as an overflow car park for audience members. Tabs and bars Motorised main tabs (aka blues ) with variable speed - track across upstage of the orchestra pit. Controls located at LX, sound and SM (stage left) positions Additional wide tabs (aka browns ) with manual winder handle - encompass the full downstage perimeter of the orchestra pit. Winder located on SL Juliette balcony. Mid-stage black tabs with manual pull cord (near to SM position, stage left) Various other bars available for hanging static or swipe cloths, although please note there is no fly tower - cloths cannot be taken up. Upstage perimeter has a white cyc plus black tabs that can be drawn across. One extendable tri-truss on two 250kg motorised winches, can be moved to numerous positions from DS to US with sufficient notice. Most bars have a total 150kg SWL. Mains supply Numerous 13A sockets available side of stage, SL and SR. Distributed 16A and 13A sockets available throughout the overstage rig. 32A three phase socket available SL, 3m above stage level. Distro to 3 x 1P 32A available plus 2 x 15m 1P 32A extensions and 32A 1P to 6 x 13A stage box. 32A single phase socket also available in control room at rear of auditorium.