Manchester and NRZ Configurable Protocol Decode

Similar documents
MIPI DigRF 3G and v4 Decode

Using Manchester and NRZ Configurable Protocol Decoders

Eye Doctor II Advanced Signal Integrity Tools

MS-32 OSCILLOSCOPE MIXED SIGNAL OPTION. Add 32 Digital Channels to a 4 Channel Oscilloscope

MS-32. Oscilloscope Mixed Signal Option. Add 32 Digital Channels to a 4 Channel Oscilloscope

Instruction Manual. Manchester and NRZ Decoder Software

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Serial Decode I2C TEN MINUTE TUTORIAL. December 21, 2011

Portable Performance for Debug and Validation

Instruction Manual. Manchester and NRZ Decoder

5 Series MSO Serial Triggering and Analysis Applications 5-SRAUDIO, 5-SRAUTO, 5-SRCOMP, and 5-SREMBD Datasheet Serial triggering

Keysight Technologies RS-232/UART Triggering and Hardware-Based Decode (N5457A) for InfiniiVision Oscilloscopes

Keysight Technologies Decoding Automotive Key Fob Communication based on Manchester-encoded ASK Modulation

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

FLEXRAY TRIGGER, DECODE, AND PHYSICAL LAYER TEST

WaveSurfer MXs. The Specs You Want The Features You Need 200 MHz to 1 GHz

CAN/LIN Measurements (Option AMS) for Agilent s InfiniiVision Series Oscilloscopes

QPHY-USB3 USB3.0 Serial Data Operator s Manual

Instruction Manual. USB3.0bus Decoder Software

Digital Audio Design Validation and Debugging Using PGY-I2C

Keysight Technologies CAN/LIN Measurements (Option AMS) for InfiniiVision Series Oscilloscopes

Product Line Card 2017

SDAIII-CompleteLinQ Multi-Lane Serial Data, Noise and Crosstalk Analysis

Operator's Manual. MS-250 Mixed Signal Oscilloscope Option

Keysight Technologies Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster. Application Note

Serial Triggering and Analysis Applications. Bus display. Bus decoding. Key features. Results table. Wave Inspector search

RS232 Decoding (Option)

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes

Quick Reference Manual

Application Note. Serial Line Coding Converters AN-CM-264

Product Line Card 2018

Logic Analysis Fundamentals

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

quantumdata 280 Test Set 280G Video Generator 280A Video Analyzer Portable, Feature Rich & Affordable!

Advanced Troubleshooting with Oscilloscopes 9000 Scope Hands-on Labs

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

Logic Analysis Basics

Logic Analysis Basics

quantumdata 280 Test Set

Application Note PG001: Using 36-Channel Logic Analyzer and 36-Channel Digital Pattern Generator for testing a 32-Bit ALU

WAVESURFER XS SERIES. The Everyday Oscilloscope that s Easy to Use

R3B Si TRACKER CABLE TEST REPORT

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Keysight Technologies Using Oscilloscope Segmented Memory for Serial Bus Applications. Application Note

WaveSurfer 3000 Oscilloscopes 200 MHz 500 MHz

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes

Expect to Make Waves.

Oscilloscopes for debugging automotive Ethernet networks

Error performance objective for 25 GbE

Agilent Technologies Pulse Pattern and Data Generators Digital Stimulus Solutions

Debugging a Mixed Signal Design with a Tektronix Mixed Signal Oscilloscope

Serial Triggering and Analysis Application Modules

Choosing an Oscilloscope

Keysight Technologies Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope

Functional Diagram: Figure 1 PCIe4-SIO8BX-SYNC Block Diagram. Chan 1-4. Multi-protocol Transceiver. 32kb. Receiver FIFO. 32kb.

Solutions to Embedded System Design Challenges Part II

STB Front Panel User s Guide

quantumdata TM G Video Generator Module for HDMI Testing Functional and Compliance Testing up to 600MHz

SignalTap Plus System Analyzer

Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope Wireless LAN Example Application

Selecting the Right Oscilloscope for Protocol Analysis Applications

Viewing Serial Data on the Keysight Oscilloscopes

Keysight Technologies FlexRay Measurements (Option FLX) for Keysight s InfiniiVision Series Oscilloscopes. Data Sheet

WaveSurfer MXs-B and MSO MXs-B Oscilloscopes

Viewing Serial Data on the Keysight Oscilloscopes

HDO4000 High Definition Oscilloscopes

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

Time-Saving Features in Economy Oscilloscopes Streamline Test

FlexRay Measurements (Option FLX) for Agilent s InfiniiVision Series Oscilloscopes

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

Keysight Technologies Segmented Memory Acquisition for InfiniiVision Series Oscilloscopes. Data Sheet

OmniStream R-Type. Single-Channel Networked AV Decoder. Introduction. Applications

Evaluating Oscilloscopes for Best Signal Visibility

Comparing JTAG, SPI, and I2C

Agilent MSO and CEBus PL Communications Testing Application Note 1352

M809256PA OIF-CEI CEI-56G Pre-Compliance Receiver Test Application

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

Essentials of USB-C DP Alt Mode Protocols

Oscilloscope innovation. Measurement confidence.

DisplayPort 1.4 Link Layer Compliance

CAP240 First semester 1430/1431. Sheet 4

quantumdata TM G Protocol Analyzer / Generator Module for HDMI Testing Deep Analysis and Compliance Testing up to 600MHz

Agilent E4887A HDMI TMDS Signal Generator Platform

Table of Contents Introduction

MultiView Zoom Simplifies Navigation of Long Records to Speed Debugging and Analysis

HDO4000 High Definition Oscilloscopes

quantumdata TM 980 HDMI 2.0 Protocol Analyzer / Generator Module Deep Analysis and Compliance Testing up to 600MHz

Oscilloscope innovation. Measurement confidence.

OmniStream R-Type. Dual-Channel Networked AV Encoder. Introduction. Applications

PHYS 3322 Modern Laboratory Methods I Digital Devices

X-Stream DSO Version 3.6 Release Notes

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

TGP2108-SM 2.5-4GHz 6-Bit Digital Phase Shifter

Analog Dual-Standard Waveform Monitor

VNP 100 application note: At home Production Workflow, REMI

The Measurement Tools and What They Do

BusFinder Series. LA3000 Series 2 in 1 Analyzer (Protocol + Logic) Manual

Transcription:

Manchester and NRZ Configurable Protocol Decode Key Features User definable protocol decoding of Manchester and NRZ encoded buses Flexible decoding of buses with bit rates up to 60 Gb/s Configurable word and packet grouping for custom protocol definition Intuitive color-coded decode is overlaid directly on physical layer waveform Convenient table display with quick zoom to message capability Search feature quickly identifies specific packets and data Quickly decode serial buses that use Manchester and NRZ encoding schemes with configurable, user-definable protocol formats. Today s oscilloscopes provide an array of protocol specific serial data decoding tools to help verify bus performance and debug system problems. These tools provide valuable insight into buses using those protocols but not all systems are built on industry standards and rely on proprietary encoding or buses not supported by oscilloscope decode tools. Flexible, User-Definable Protocol Decoding The Configurable Manchester and NRZ Decode options enable flexible, user-definable protocol decoding of serial buses built with these encoding schemes from 10 b/s to 60 Gb/s. The physical layer specs like bit rate, idle state and polarity can be easily defined enabling quick decoding of every bit transmitted on the bus. Higher level decode can be done by configuring bits to words and then words to packets. Configure and Decode Complex Protocols Define the number of sync bits, header or pre-amble bits, data bits and footer or CRC bits to build a custom protocol decoder for a proprietary bus or decode Manchester or NRZ based industry standard buses like PSI5, DALI, LONworks, and proprietary NRZ protocols. Support on Multiple Oscilloscope Platforms The configurable Manchester and NRZ decode option is available on a wide range of oscilloscope models from 200 MHz to 65 GHz.

DEFINE, CONFIGURE, DECODE Manchester and NRZ encoding schemes both use a variety of methods for making bits into words, words into packets and packets into protocols. The configurable Manchester and NRZ decode capabilities are designed to provide the flexibility needed to display decoded protocol information built on these encoding schemes. This flexibility enables quick decoding of protocols built on industry standards or custom, proprietary protocols. 1 2 3 4 5 6 7 User-definable protocol controls enable flexible serial bus decoding. Protocol Decode Setup 1. Decode data packet by grouping bits into words 2. View decoded data in Hex, ASCII or Decimal 3. Set decode bit order as LSB or MSB Word, Packet, Frame Setup 5. Group up to 32 bits for address, pre-amble or sub-address information 6. Choose custom number of bits from 0 32 for word size 4. Select a start point for decoding so that only transitions of interest are decoded. 7. Define CRC or footer information by setting a specific amount of post-pad bits 2

Intuitive Decode Color-coded overlays display the protocol decode directly on top of the physical layer waveform for an easy-to-understand visual display. The decode information condenses or expands depending on the timebase or zoom setting, simplifying both routine verification and complex troubleshooting. Powerful Search Quickly search through long captures of decoded Manchester or NRZ encoded buses for specific details such as Data, Sync, Interframe Gap or Status. Search functionality and user interface provides an easy way to step through search results to isolate specific areas of interest. Convenient Table Turn the oscilloscope into a protocol analyzer with the table display of protocol information. Configure the table to display information, such as, sync, pre & post data, and export table data to an Excel file. Display decoded values in an easy-to-understand table. 3

SPECIFICATIONS & ORDERING INFORMATION Manchester / NRZ Definition Protocol Setup Select Bit rate (10 bit/s - 60 Gbit/s), Idle State (IdleLow, IdleHigh, Don t Care), Polarity (Low = 0, Low = 1) Decode Capability Format Basic Setup Decode Setup # of Decode Waveforms Location Visual Aid Pattern Search Supported Encoding Variants Compatible With... Bits, Words Bit rate, Idle State, Polarity First Transition Used (0-400), Bit Stretch Tolerance (0-100 %), Sync Bits (0-1000), PrePad Bits (0-32), Data Bits (1-32), PostPad Bits (0-32) Up to 4 buses may be decoded at one time. In addition, zooms can be displayed (with decoded information). Overlaid over waveform, on Grid Color Coding for Idle, timeout, Prepad, Data, PostPad. Decode information is intelligently annotated based on timebase setting. Search Capability Search for the following: Time, Sync, Prepad, Data, Postpad, Interframe Gap and Status. Selection available for use of defining decimal or hexadecimal search value with Data mode = Words Other NRZ-L Manchester Bi-Phase-L (also called Manchester II), IEEE 802.3, Differential bi-phase mark, Differential bi-phase space. (Single Wire) Fully compatible with WaveSurfer 10/MXs-B/MSO MXs-B Series, HDO4000 Series, WaveRunner Xi/Xi-A Series, WaveRunner 6 Zi Series, HDO6000 Series, HDO8000 Series, WavePro 7 Zi Series, WaveMaster 8 Zi Series, LabMaster 9 Zi-A Series, and LabMaster 10 Zi Series. Bandwidth of oscilloscope must be equal to bit rate with a minimum oscilloscope sample rate of 4x the bit rate. Ordering information Product Description Product Code Product Description Product Code Manchester Decode Option WaveSurfer MXs/MSO MXs-B WaveSurfer 10 HDO4000/HDO4000-MS WaveRunner 6 Zi HDO6000/HDO6000-MS HDO8000/ HDO8000-MS/MDA800 WavePro 7 Zi/Zi-A WaveMaster 8 Zi-A LabMaster 9 Zi-A LabMaster 10 Zi WSXs-Manchesterbus D WS10-Manchesterbus D HDO4K-Manchesterbus D WR6Zi-Manchesterbus D HDO6K-Manchesterbus D HDO8K-Manchesterbus D WPZi-Manchesterbus D WM8Zi-Manchesterbus D LM9Zi-Manchesterbus D LM10Zi-Manchesterbus D NRZ Decode Option NRZ Decode Option for WaveSurfer MXs/MSO MXs-B NRZ Decode Option for WaveSurfer 10 NRZ Decode Option for HDO4000/HDO4000-MS NRZ Decode Option for WaveRunner 6 Zi NRZ Decode Option for HDO6000/HDO6000-MS NRZ Decode Option for HDO8000/HDO8000-MS/MDA800 Customer Service WSXs-NRZbus D WS10-NRZbus D HDO4K-NRZbus D WR6Zi-NRZbus D HDO6K-NRZbus D HDO8K-NRZbus D Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years, and our probes are warranted for one year. This warranty includes: No charge for return shipping Long-term 7-year support Upgrade to latest software at no charge 1-800-5-LeCroy teledynelecroy.com Local sales offices are located throughout the world. Visit our website to find the most convenient location. 2015 by Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders. manchester-nrz_ds_28aug15

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Teledyne LeCroy: HDO4K-MANCHESTERbus D