PATCH CORDS, PLUGS & CABLES

Similar documents
PREMIUM 5e F/UTP PRODUCTS

CATEGORY 6A CABLING SOLUTIONS

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

CATEGORY 6A CABLING SOLUTIONS

STRUCTURED CABLING SYSTEMS (SCS)

Combining Value and Performance Like No One Else

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

CATEGORY 6 CABLING SOLUTIONS

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

CATEGORY 5e CABLING SOLUTIONS

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

GenSPEED Category 5e Cables 3

DINTEK LAN Cabling Systems

Copper Solution Contents Cabinets Fiber Optic Solution

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

Detailed Specifications & Technical Data

Cat.6 4 Pair UTP Cable

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

MX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

Professionally Install Products Right the First Time. TOOL-CRIMP Radial Linear compression tool for BNC, F & RCA connectors

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

SHIELDED DIGITAL CABLES (1249C SERIES)

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

ULTIMATE SNAP-N-SEAL

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

CUSTOM COLLECTION. Welcome to the Tributaries Custom Collection.

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

Table of Contents. Open Matrix System (OMS) 1-2

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

Content BULK CABLES VIDEO CABLES AUDIO CABLES EXTENDERS USB CABLES ETHERNET CABLES VIDEO BALUNS CONNECTORS ADAPTERS PATCH PANELS & WALLPLATES TOOLS

Follow The Leader In Shielded Technology

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

LCS2 Cat. 6 RJ 45 Patch panels and units

LD Series High Performance Loose Tube Fiberoptic Cables

FUTURE PROOF YOUR CONNECTIONS

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

Compact Module. Category 6 FTP Cabling System

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Detailed Specifications & Technical Data

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

Detailed Specifications & Technical Data

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

STRUCTURED CABLING SOLUTIONS

HARTING Ethernet cabling cables and connectors, 4 wire

Magic Patch Patch Leads & Accessories

ENGINEERING COMMITTEE Interface Practices Subcommittee. ANSI/SCTE (Formerly IPS SP 001)

What really changes with Category 6

VERICOM GLOBAL SOLUTIONS Knoxville, Tennessee

Coaxial Cable Termination

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

SMART CLASSix 24/48 UTP Patch Panels -

ODW-621. RS-232 Point-to-point applications

Multi-Media Installation Guide

92656 XR RTQ RG-6 F Comp Connector 100JR

Jumpers & Pigtails. Fiber Type OM1, OM3, OM4, 0S1/OS2. Polarity Correction SC and LC duplex clip allows for polarity correction

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Premise Installation Guide

Series MCX 50 micro miniature connectors

Type "N" Connectors. Type "N" Interface Dimensions

ENTERPRISE COPPER SOLUTIONS

SECTION 4 TABLE OF CONTENTS

Modular Data Plug RJ45 Cat5e. Material, Color, and Finish. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

D-COAX, Inc. D-COAX Male-Female 1501 Series Cables and Cable Pairs. High Frequency, Skew Matched, Phase Stable Cable Pair (40 GHz)

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

Bravo AV s Structured or Whole-House Wiring Approach

Connect with the industry s best CAT6 and CAT5e channel solutions!


Non Magnetic Connectors

Detailed Specifications & Technical Data

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

FREEDM Loose Tube Interlocking Armored Cables

AMERICAN NATIONAL STANDARD

SPECIAL SPECIFICATION 6559 Telecommunication Cable

BUS UNITRONIC BUS CAN

SPECIAL SPECIFICATION 2344 TMC Support Equipment

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

SECTION 7 -- CROSS-CONNECT SYSTEMS

SPECIAL SPECIFICATION 8540 Telecommunication Cable

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Non Magnetic Connectors Product Catalog

Table 4-1: Rating Levels

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

Transcription:

PATCH CORDS, PLUGS & CABLES

3.1 SECTION CONTENTS Modular Cords...3.2 Cable Assemblies...3.3 Plugs & Connectors...3.4 Bundled Cable...3.5 Category 5e & 6 UTP Cable...3.6 Coax Cable...3.7 Fiber Optic Cable...3.8 Category 3 25-Pair UTP Cable...3.9

3.2 PATCH CORDS, PLUGS & CABLES THE SIEMON COMPANY MC 5 MODULAR CORDS Siemon MC 5 modular cords can be used as patch cords within the Command Center enclosure or as equipment cords between the data outlet and computer. Made from premium stranded cable, every MC 5 cord is factory tested to ensure optimum category 5e performance and reliability. MC5-8T-(XX)-B(XX)......... Double-ended, 4-pair modular stranded cord, white jacket with colored boot, T568A/T568B wiring Use 1st (XX) to specify cord length:.5 = 0.15m (6 in.)*, 01 = 0.30m (1 ft.), 03 = 0.91m (3 ft.), 05 = 1.52m (5 ft.), 07 = 2.13m (7 ft.), 10 = 3.05m (10 ft.), 15 = 4.57m (15 ft.), 20 = 6.10m (20 ft.), 25 = 7.62m (25 ft.) Use 2nd (XX) to specify boot color: 02 = white, 04 = gray, 06 = blue Add B for bulk project pack of 100 modular cords. *6 inch cords are designed for use in Command Center Enclosures COMMAND CENTER ENCLOSURES PAGES 1.2 1.4, MAX MODULES PAGES 2.6 2.7 Siemon MC 5 modular cords are constructed using high performance category 5e cable Siemon modular plugs exceed FCC CFR 47 part 68 subpart F and IEC 603-7 specifications and have 50 microinches minimum of gold plating over nickel. The result is superior transmission performance and long-term resistance to corrosion from humidity, extreme temperatures, and airborne contaminants Stringent factory transmission test procedures ensure category 5e component and channel compliance MC 6 MODULAR CORDS To achieve category 6* performance, match MC 6 modular cords with MAX 6 modules throughout the home network. MC 6 cords utilize patented technology to arrange and maintain conductor position for optimum pair balancing. MC6-8T-(XX)-B(XX)......... MC 6, double-ended, 4-pair stranded modular cord,t568a/b wiring white jacket with colored insert-molded boot Technical Tip! Factory terminated modular cords are required to achieve consistent category 5e or 6* channel performance. Field termination is not recommended. Use 1st (XX) to specify cord length:.5 = 0.15m (6 in.)*, 01 = 0.30m (1 ft.), 03 = 0.9m (3 ft.), 05 = 1.5m (5 ft.), 07 = 2.1m (7 ft.), 10 = 3.1m (10 ft.), 15 = 4.6m (15 ft.), 20 = 6.1m (20 ft.), 25 = 7.6m (25 ft.) Use 2nd (XX) to specify boot color: 01 = black, 02 = white, 06 = blue Add B for bulk project pack of 100 modular cords. *6 inch cords are designed for use in Command Center Enclosures *At the time of this catalog printing, category 6/class E specifications were under development by TIA/EIA and ISO/IEC. COMMAND CENTER ENCLOSURES PAGES 1.2 1.4, MAX 6 MODULES PAGES 2.8 2.9 Siemon Modular Plugs with Yellow KeyBar Patented KeyBar technology perfectly positions conductors for optimum pair balance to the point of termination Insert-Molded Strain and Bend Relief Provides improved plug-to-cable retention and maximum performance by preventing pair deformation, as caused by mechanical strain 100% Transmission Testing All cords are 100% transmission tested to 250 MHz using a network analyzer to guarantee field performance

www.homecabling.com PATCH CORDS, PLUGS & CABLES 3.3 RG59 COAX CABLE ASSEMBLY The RG59F-(XX) uses 75 ohm cable and includes an RG59 F-type connector on each end. It is factory assembled and tested to ensure continuity. The assembly meets all applicable SCTE and Bellcore specifications and exhibits superior levels of return loss, insertion loss, and shield effectiveness. RG59F-(XX)............... RG59-to-RG59 cable assembly, black jacket Use (XX) to specify length: 01 = 0.30m (1 ft.), 03 = 0.91m (3 ft.), 07 = 2.13m (7 ft.), 10 = 3.05m (10 ft.) F-TYPE CONNECTORS AND BULKHEADS PAGE 3.4 25-PAIR CABLE ASSEMBLY Used to join a key system to a connecting block, our 25-pair cable assemblies are 100% factory-tested for opens, shorts, and continuity. They feature FCC compliant gold plated contacts for extended reliability. Category 3 connector ends are available in singleended male or female, double-ended male or female, or one male/one female configurations. All 25-pair cable assemblies are made with ANSI/TIA/EIA-568-B.2 category 3 compliant cable. CATEGORY 3 CABLE ASSEMBLIES A25B-DE-(XX)............. 25-pair, double-ended, cable assembly with female connectors A25B-SE-(XX)............. 25-pair, single-ended, cable assembly with female connectors B25A-(XX)................ 25-pair, double-ended, cable assembly with one male and one female connector B25B-DE-(XX)............. 25-pair, double-ended, cable assembly with male connectors B25B-SE-(XX)............. 25-pair, single-ended, cable assembly with one male connector Use (XX) to specify length: 5 = 1.52m (5 ft.), 10 = 3.05m (10 ft.), 15 = 4.57m (15 ft.), 25 = 7.62m (25 ft.) PRE-WIRED S66 CONNECTING BLOCKS PAGE 5.9 HYDRA The category 3 Hydra gathers multiple modular cords and terminates them into a single male or female 25-pair connector. Each of the individual cords is labeled, which provides easy identification during installations, moves, or changes. All Hydras are made using FCC compliant 25-pair connectors and modular plugs. HYD(X)-24-(XX)............ 24, 1-pair legs, 6-position plugs, USOC wiring HYD(X)-12-(XX)........... 12, 2-pair legs, 6-position plugs, USOC wiring Use (X) to specify 25-pair connector gender: M = Male connector, F = Female connector Use (XX) to specify length: 03 = 0.91m (3 ft.), 07 = 2.13m (7 ft.), 10 = 3.05m (10 ft.) PRE-WIRED S66 CONNECTING BLOCKS PAGE 5.9

3.4 PATCH CORDS, PLUGS & CABLES THE SIEMON COMPANY EZ-TWIST COAX CONNECTOR For use with RG59 and RG6 cable, Siemon s EZ-Twist is a rugged, feature-rich coax connector. It is easy to install and delivers outstanding performance. Without using tools, the push-to-lock design produces tight connections for optimized signal transmission. The EZ-Twist is supplied with an installation aid to assist in terminating connectors onto cable. HC-EZ-(X)-(X).............. EZ-Twist coax connector, bag of 50 Use 1st (X) to specify cable type: 5 = RG59, 6 = RG6 Use 2nd (X) to specify shield type: T = Tri-shield, Q = Quad-shield HOMENET CABLE PAGE 3.5, COAX CABLE PAGE 3.7 HC-EZ Exploded View Terminated HC-EZ RG6 F-TYPE COAX CONNECTORS The RG6 connector is a high quality coaxial connector designed to terminate RG6 coaxial cable that has a standard diameter over jacket (DOJ) of 6.9mm (0.27 in.). The connector meets SCTE and Bellcore specifications and is constructed of high quality brass with corrosion-resistant plating. The long ribbed ferrule ensures maximum connector to cable retention. The FB is a high quality coax bulkhead that allows the connection of video inputs to installed coax cable runs. These high quality bulkheads can also accommodate satellite feed signals. When used in conjunction with the HC-RF-HP-80 or HC-RF-FP-80 panels, they can be used to build a coax patching field for added video distribution. HC-RG6F................. RG6 F-type connector, bag of 50 HC-FB................... F-type coax bulkhead, bag of 50 COAX CABLE PAGE 3.7, COAXIAL CRIMP TOOL PAGE 4.7 HC-RG6F HC-FB UNIVERSAL MODULAR PLUG Our patented universal modular plug eliminates the need to stock more than one size modular plug. The UP-2468 permits field-termination of modular cords in 2-, 3-, or 4-pair increments and terminates twisted pair cable with 26-22 AWG (0.40mm - 0.64mm) solid or 7-strand conductors with insulated conductor diameter of 0.86-0.99mm (0.034-0.039 in.). UP-2468................. Universal modular plug PT908 CRIMP TOOL PAGE 4.6 MODULAR PLUGS We offer modular plugs in standard configurations to terminate modular cords for patching or equipment connection applications. Modular plugs can be terminated to the exact cable length needed in order to maintain a neater, more organized installation. The plugs terminate twisted-pair cable with 26-22 AWG (0.40mm - 0.64mm) solid or 7-strand conductors with an insulated conductor diameter of 0.86-0.99mm (0.034-0.039 in.). P-8-8............ 8-position modular plug with 8 contacts (compatible with Siemon and Amp crimp tools) PS-8-8........... 8-position shielded modular plug with 8 contacts (compatible with Siemon and Amp crimp tools) P-6-6............ 6-position modular plug with 6 contacts* P-8-8SS.......... 8-position modular plug with 8 contacts (compatible with Siemon and Stewart crimp tools) PT908 CRIMP TOOL PAGE 4.6 Technical Tip! Factory terminated and tested modular cords are required to achieve consistent category 5 or higher compatibility. Field termination is not recommended. P-6-4............ 6-position modular plug with 4 contacts* *Siemon 6-position plugs provide empty slots in the outer positions to prevent deformation of jack pins 1 & 8 when inserted into an 8-position modular jack.

www.homecabling.com PATCH CORDS, PLUGS & CABLES 3.5 HOMENET II CABLE Siemon Homenet II bundled cable is the easiest solution for meeting TIA 570-A Grade 2 requirements. By combining two category 5e and two RG6 Quad Shield coax cables, the Homenet II bundled design meets the Grade 2 standard without the need to pull individual cables. The performance of Homenet II cable future proofs the home. The bundled design also differentiates it from other high and low voltage cables running throughout the home. Part# HC-HMNT-2-06.......... Bundled cable consisting of 1 RG6 Quad Shield white jacket, 1 RG6 Quad Shield black jacket, 1 category 5e 4-pair UTP blue jacket, and 1 category 5e 4-pair UTP gray jacket For detailed specifications, see pages 3.6 & 3.7. Note: Performance of individual cables may change when bundled together. Bundled cable performance cannot be measured due to multiple signals running concurrently. Note: Cable supplied on reels 152m (500 ft.) Contact your local sales representative for cable availability and delivery lead time. Cable designs and specifications subject to change without notice. Application Example: The Siemon Home Cabling System SM utilizing Homenet II cable. Pull one cable from the Command Center to each outlet. This will allow distribution of multiple applications to every room. EZ-TWIST AND RG6 COAX CONNECTOR PAGE 3.4, ALLPREP CABLE PREPARATION TOOL PAGE 4.7

3.6 PATCH CORDS, PLUGS & CABLES THE SIEMON COMPANY CATEGORY 5e & 6 4-PAIR SOLID CABLE 5e COMPLIANCE ANSI/TIA/EIA-568-B.2 category 5e ISO/IEC 11801:2000 Edition 1.2 Part# 9C5R4................. Riser (CMR, CSA FT4), gray Jacket 9C5R4-06............... Riser (CMR, CSA FT4), blue Jacket 5e & 6 APPLICATIONS Voice T1 10BASE-T, 100BASE-T, 1000BASE-T 4/16 Mbps Token Ring 51/155 Mbps ATM, 100Mbps TP-PMD 100VG-AnyLAN 5e & 6 PRODUCT CONSTRUCTION 0.51mm (24 AWG) solid bare copper 4-pairs cabled together with a rip cord 5.46mm (0.22 in.) max jacket diameter 0.97mm (0.04 in.) max conductor insulation diameter Sequential meter markings on jacket 5e ELECTRICAL CHARACTERISTICS DC Resistance (max) Delay Skew (max) Return Loss (min) 1 f < 10 10 f < 20 20 f < 100 Input Impedance (no impedance averaging allowed) 9.4 ohms/100m @ 20 C 35 ns/100m 20 + 5log(f) db 25 db 25-7log(f/20) db 100 ohms ± 15% Contact your local sales representative for cable availability and delivery lead time. Cable designs and specifications subject to change without notice. 6 ELECTRICAL CHARACTERISTICS DC Resistance (max) Delay Skew (max) Return Loss (min) 1 f < 10 10 f < 20 20 f < 100 Input Impedance (no impedance averaging allowed) 1 f 100 1 f 200 1 f 300 9.4 ohms/100m @ 20 C 25 ns/100m 20 + 5log(f) db 25 db 25-7log(f/20) db 100 ohms ± 15% 100 ohms ± 22% 100 ohms ± 32% 6 COMPLIANCE Proposed ISO/IEC and TIA category 6 Exceeds ANSI/TIA/EIA/-568-B.2, ISO/IEC 11801:2000 Edition 1.2 Part# 9C6R4................... Riser (CMR, CSA FT4), gray Jacket 9C6R4-06................ Riser (CMR, CSA FT4), blue Jacket Note: Cable supplied on a reel in a tangle-free dispenser carton, 305m (1,000 ft.) 5e TRANSMISSION PERFORMANCE Maximum Minimum Minimum Maximum Frequency Attenuation NEXT Loss ELFEXT Propagation Delay (MHz) (db/100m) (Power Sum) (Pair-to-Pair) (ns/100m) (db/100m) (db/100m) 0.772 1.8 64 1 2.0 62 61 570 4 4.1 53 49 552 8 5.8 49 43 547 10 6.5 47 41 545 16 8.2 44 37 543 20 9.3 43 35 542 25 10.4 41 33 541 31.25 11.7 40 31 540 62.5 17.0 35 25 539 100 22.0 32 21 538 6 TRANSMISSION PERFORMANCE Maximum Minimum Minimum Minimum Maximum Frequency Attenuation NEXT Loss NEXT ELFEXT Propagation Delay (MHz) (db/100m) (Pair-to-Pair) (Power Sum) (Power Sum) (ns/100m) (db) (db) (db) 1 2.0 74 72 65 570 4 3.7 65 63 53 552 10 5.9 59 57 45 547 16 7.6 56 54 41 545 20 8.5 55 53 39 543 25 9.5 53 51 37 542 31.25 10.7 52 50 35 541 62.5 15.5 47 45 29 540 100 19.9 44 42 25 539 200 29.1 40 38 19 538 250 33.0 38 36 17 537 ALLPREP CABLE PREPARATION TOOL PAGE 4.7

www.homecabling.com PATCH CORDS, PLUGS & CABLES 3.7 RG6 QUAD SHIELDED COAX CABLE COMPLIANCE NEC article 725 & 820 UL Subject 13 & 1581 types CL2/CATV APPLICATIONS CATV broadcast LAN controls Video displays Satellite Cable Internet Closed Circuit Television (CCTV) High Definition Television (HDTV) 2.2 GHz Bandwidth PRODUCT CONSTRUCTION Broadcast coaxial 75 ohm RG6/U 18 AWG solid bare copper Cellular polyethylene dielectric (PE) Dual, bonded coaxial shielding tape, 100% Dual aluminum braid shield @ 60%/40% Polyvinyl chloride jacket (PVC) Temperature rating: -20C to +60C Part# RG6-01................ RG6 quad shield,coax cable, black jacket RG6-02.................. RG6 quad shield coax cable, white Jacket Note: Cable supplied on reels 305m (1,000 ft.) AWG Size RG Type Stranding Rating Jacket Type Jacket Thickness ELECTRICAL CHARACTERISTICS 18 Solid 6/U Solid Bare Copper CL2/CATV PVC 0.686mm (0.027 in.) Shield Coverage Nominal Impede. Nominal Velocity Insulation Type Nominal Core O.D. Nominal Cap. O/A Dual Tape 100% O/A Dual Braid 1-60%, 1-40% 75 Ohms 84% Cellular PE 4.52mm (0.18 in.) 16.2 pf/ft. TRANSMISSION PERFORMANCE Frequency MHz/GHz Nominal Attenuation db100 100 MHz 2.5 db 400 MHz 4.0 db 1.0 GHz 6.5 db 1.45 GHz 7.0 db 2.2 GHz 9.0 db Contact your local sales representative for cable availability and delivery lead time. Cable designs and specifications subject to change without notice. EZ-TWIST AND RG6 COAX CONNECTOR PAGE 3.4

3.8 PATCH CORDS, PLUGS & CABLES THE SIEMON COMPANY DUPLEX ZIPCORD FIBER OPTIC CABLE COMPLIANCE RISER RATED: ANSI/TIA/EIA-568-B.3 ISO/IEC 11801:2000 Edition 1.2 Communications Type OFNR (UL) and CSA FT4 c(ul) APPLICATIONS Fiber to the desk Connect network to network PRODUCT CONSTRUCTION/FEATURES Flexible resilient jacket Aramid yarn strength members Flexible tight buffer for easy connectorization Part# Fiber # of Sub-Units Count (Fibers/Sub Unit) 9F(X)C1-2E.305........... 2................. 2 (1) 9F(X)C1-2E.305 Use (X) to specify fiber type: 5 = 50/125µm Multimode, 6 = 62.5/125µm Multimode, 8 = Singlemode Note: Fiber cable supplied on wooden reels 305m (1,000 ft.) Duplex cable side view (Not to scale) OPTICAL CHARACTERISTICS FIBER TYPE Typical Maximum Minimum Modal Guaranteed Wavelength Attenuation Attenuation Bandwidth Transmission Distance* nm (db/km) (db/km) (MHz-Km) Meters Standard Premium Standard Premium Standard Premium Standard Premium 50/125 62.5/125 850 2.6 2.6 3.5 3.0 500 500 550 600 1300 0.6 0.6 1.0 1.0 500 1000 550 600 850 2.9 2.9 3.5 3.5 200 220 275 300 1300 0.9 0.9 1.0 1.0 500 1000 550 550 *The protocol pertinent to the transmission distance as noted is gigabit ethernet per IEEE 802.3Z. Contact your local sales representative for cable availability and delivery lead time. Cable designs and specifications subject to change without notice. FIBER ADAPTER MODULES AND CONNECTORS PAGE 2.15

www.homecabling.com PATCH CORDS, PLUGS & CABLES 3.9 CATEGORY 3 25-PAIR SOLID CABLE COMPLIANCE ANSI/TIA/EIA-568-B.2 category 3 Qualified for Propagation Delay and Delay Skew APPLICATIONS Voice PRODUCT CONSTRUCTION 0.51mm (24 AWG) solid bare copper 25-pairs cabled together with a rip cord and and colored core binder 9.14mm (0.36 in.) max jacket diameter 0.97mm (0.04 in.) max conductor insulation diameter Sequential meter markings on jacket 9C3R25 Part# 9C3R25................ 25-Pair, Riser (CMR, CSA FT4), gray Jacket Note: 25-Pair cable supplied on a reel, 305m (1,000 ft.) ELECTRICAL CHARACTERISTICS DC Resistance (max) @ 20 C (max) Delay Skew (max) Structural Return Loss (min) 1-10 MHz 10-16 MHz Characteristic Impedance 9.4 ohms/100m 35 ns/100m 12 db 12-10log(f/10) db 100 ohms ± 15% TRANSMISSION PERFORMANCE Maximum Minimum Maximum Frequency Attenuation NEXT Loss Propagation Delay (MHz) (db/100m) (Worst Pair) (ns/100m) (db) 0.772 2.2 43 1 2.6 41 570 4 5.6 32 552 8 8.5 27 547 10 9.7 26 545 16 13.1 23 543. Contact your local sales representative for cable availability and delivery lead time. Cable designs and specifications subject to change without notice.