AT&T CIB 3067 CALL ACCOUNTING SYSTEM (CAS) MODEL 100 (61370) ( )

Similar documents
MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

Digital Magic On Hold System

Digital Magic On Hold SM Tape Deck Model DMOH Installation and Operation Instructions

APSPB PUSH BUTTON ZERO Installation Manual

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. June 2015 Part Numbers FIBER DRIVER

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

DVI Rover 700 User Guide

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

User Instructions. 16 SCB Sync Station.

instruction manual model 315 video sync separator s/n

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

The Phono Box SUMIKO Fifth Street Berkeley, CA sumikoaudio.com

MWCS-AT9-MYA MYE 900MHz (Wireless) CableSAT

Copyright Black Box Corporation. All rights reserved.

MWCS-CC9-MYA MYE 900MHz CableSAT TV Channel Changer

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

VideoSplitter HDMI 4K PT

MYE TV Audio Grabber

User Guide. HDMI Fiber Optic Extender. DVI-7350a

1X4 HDMI Splitter with 3D Support

blink USER GUIDE Bluetooth capable Reclocker Wyred 4 Sound. All rights reserved. v1.0

Quick Installation Guide. Indoor / Outdoor Antenna, Antenna Cable & Surge Arrestor H/W: V2

User s Guide. 5.8GHz Wireless A/V Signal Sender

T850 Day & Night Security Camera

HDMI over Cat 5/6 Extender w/ Serial & IR 330ft (100m)

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

WXL-2F, WXL-1F, WXL-2M, WXL-1M

X-Series Expansion Cards. X-Video Card

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

Enable-IT 821P PoE Extender Quickstart Guide Professional Grade Networking

VideoEase HDMI 3x1 Switcher Kit (110V) Installation Guide

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Dystrybucja i sprzedaż: Meditronik Sp. z o.o Warszawa, ul. Wiertnicza 129, tel. (+48 22) , fax (+48 22)

Enable-IT 824WP Outdoor Waterproof PoE Extender Kit Quickstart Guide Professional Grade Networking

DISH Pro Hybrid 42 Switch Installation Guide

DisplayPort Extender over 2 LC Fibers

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

AUDIO WIRELESS. with IR Extender Feature OWNER S MANUAL SENDER T CAT. NO

AITech ProA/V Media Extender 5GHz Digital

For use with QED and hardwired control panels ONLY!

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

CGA0101 Wireless Cable Gateway Quick Installation Guide

Designed in Colorado, USA. Bluetooth Cable. Quick Start Guide

instruction manual Model 619YY video dual vertical line generator s/n

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

USER S MANUAL. Deuce HD User's Manual WORLD HEADQUARTERS

Single Station Waterproof Timer

LF-IRX. 12 Month Limited Warranty LF-IRX. Remote Control Extender. Owner s manual. For customer service and technical information::

CrystalView DVI Micro-DL Extender

Electric Motorized Projection Screen Spectrum Series

Quick Installation Guide. Indoor / Outdoor Antenna, Antenna Cable & Surge Arrestor

HDTV SIGNAL AMPLIFIERS. 34 series USER GUIDE GUÍA PARA EL USUARIO MODE D EMPLOI CM-3410 CM-3412 CM-3414 CM-3418

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

Picture Fan. display your photos, graphics & messages

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

VGA to Composite/S-Video Converter VGA2VID

Kramer Electronics, Ltd. USER MANUAL. Model: 810B. Black Burst / Audio Generator

Doorphone Video Intercom

user guide SLX-111 also available: SLX-100, SLX-214 transmitter & receiver pair tel: +44 (0) ,

DVI-D Fiber Optic Cable

DisplayPort Extender over 2 LC Fibers

HDMI to Composite Converter. User s Guide

Enable-IT 865 Q PRO Gigabit Professional Grade PoE Extender Kit Quickstart Guide

HDMI over Cat5 Video Extender with RS232 and IR Control ST121UTPHD2

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

User Guide. HDMI Active Cable Extender. DVI-7370c

2-Port Hub Type 1 2-Port Hub Type 3 Unshielded 2-Port Hub Type 3 Shielded

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. Dtrovision LLC

In-Band OAM Gigabit Ethernet to MM LC Fiber Media Converter - 550m, Metal Housing

instruction manual Model 619D video dual cross hair generator s/n

Satellite Radio. Expand Your Factory Radio ISSR bit & 29-bit LAN. Owner s Manual Gateway. add. Harness Connection USB. Port 1 Port.

HTP1502W1 Remote Controlled Multicolor Lighting System

Omnidirectional TV/FM Antenna

Digital Tiny Traveler Wireless Baby Monitor for Your Car

Quick Installation Guide TV-H110 H/W: V1

Indoor/Outdoor Security System with Quad Monitor User s Manual

HDMI over Cat 5e/6 Extender - 70m

INSTRUCTION MANUAL SUPER LASER

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

USER MANUAL Table of Contents

User Guide. Centrex Recording Interface

Quick Start Guide ABOUT THE CAMERA

Installation Manual SaVi Note Underwater LED Light

instruction manual x-y indicator model 620D

Kramer Electronics, Ltd. USER MANUAL. Models: WPN-11, XGA/Component/CV/YC Transmitter WPN-12, XGA/Component/CV/YC Receiver

Transvue HDMI 4K2K Scaler

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro

4-to-1 HDMI 1.3 Switch VS410HDMIE

Congratulations on your mcable purchase! The mcable delivers the best possible picture to your HD or 4K TV by up-converting 480p and 720p content to

Expand Your Factory Radio add Satellite Radio Harness Connection

innkeeper LTD Digital Hybrid User Guide JK Audio

TAC1 Telephone Entry System

USER S MANUAL. Save this manual for future reference. For a digital version of this manual, visit

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

PoE Over Coax Extender Kit

Transcription:

AT&T CIB 3067 CALL ACCOUNTING SYSTEM (CAS) MODEL 100 (61370) (845656818)

Contents Title Introduction Installation System Options Percentage Markup Line Spacing Suppression of Records for Incoming Calls Suppression of Records for Local Calls Suppression of Records for Calls Without Account Numbers Changing the Baud Rate of the CAS s Output Testing Procedures System Diagnostics Message Call Record Verification Reports Chronological Report Summary Reports by Hour by Line Number by Extension Number by Account Number Troubleshooting Tables Maintenance Information Updated Custom Cartridges Ordering Information Other Important Information Warranty Information Interference Information Specification Table Page 2 4 8 15 17 21 22 23

CIB 3067 Call Accounting System (CAS) Model 100 (61370) Introduction When connected to a printer and the Station Message Detail Recording (SMDR) Module in your Model 1030 or 3070 control unit, the Call Accounting System (CAS) Model 100 (Figure 1) calculates the cost of calls made to outside numbers, stores the cost information, and generates chronological and summary reports. CAS microprocessor CAS custom cartridge Power supply Figure 1 Call Accounting System (CAS) Model 100 After each incoming or outgoing call is completed, a call record is printed on the chronological report (Figure 2). Each call record includes the date and time of each call, its duration in minutes, the extension, and line number on which the call was made. If the call is outgoing, the call record also includes the cost of the call, the number dialed, and a two-character location abbreviation for the state to which the call was made. If an account code is entered when a call is made, it is printed on the chronological report. Account codes are helpful for billing customers and allocating telephone costs to different departments in your business. 2

Number Account Date Time Extension Dialed Location Duration Cost Number Line# 08:22 08:45 09:23 09:27 09:37 09:47 10:12 10:22 10:45 11:23 11:25 11:27 11:35 12:07 12:12 12:25 13:01 13:21 13:37 13:41 14544466 18004312020 14137651000 02128885555 19878989 7331275 15551212 12035551212 14154315154 14137651000 02128885555 7388928 7331275 15551212 0114466825 8901024 17168901064 17168901011 NJ TF MA OP NJ NJ IN IN CA MA OP NJ NJ IN OV NJ NY NY 001 011 006 037 032 010 001 001 001 006 027 042 006 007 001 013 010 021 008 001 $00.42 $00.00 $02.39 $00.00 $03.97 $01.12 $00.50 $00.50 $00.69 $02.39 $00.00 $02.56 $00.72 $00.00 $00.50 $11.05 $00.99 $00.00 $03.13 $00.54 1567890 219581985 5678 123 1238 5678 1256 567890 9581985 5678 5678 567890 56 567789 01 02 03 07 25 30 00 01 02 03 07 25 30 20 00 00 01 04 10 14 Figure 2 Chronological Report When a call record with a new date is received by the CAS, the previous day s chronological report is ended and reports containing summary information (Figure 3) are printed. There are four summary reports produced: Summary of Calls by Hour of the Day, Summary of Calls by Line Number, Summary of Calls by Extension Number, and Summary of Calls by Account Number. These reports list the total number of calls, their duration, and cost. SUMMARY BY LINE # 12/12 LINE CALLS DURATION COST 00 01 02 03 04 07 10 11 14 20 25 30 0003 0003 0002 0002 0002 0002 0002 05 02 02 02 21 64 08 01 00 07 74 06 0012.05.91.69 0004.78 0003.13.50.54 0006.53.84 Figure 3 Summary Report of Calls by Line Number 3

Installation The CAS comes with a custom cartridge which contains the costing tables that are used to calculate the cost of calls made to outside numbers. You will need the following equipment, which you ordered at the same time as your CAS, for installation: 14-foot (4-pair) modular cord 355AF (4-pair to RS232 serial data) adapter The CAS may be installed 14 feet from the control unit using a 14-foot modular cord or up to 1,000 feet from the control unit following the voice terminal wiring plan in your system s installation guide. NOTE: Before installing the CAS, be sure that a SMDR Module is installed in slot 5 of your control unit. Also make sure that the SMDR options have been administered according to the instructions in your administration manual s section titled "Administering SMDR Options." 1. 2. Choose a location for your CAS following the guidelines below: The distance between the CAS and a 3-prong outlet must be less than five feet. The 3-prong outlet must not be controlled by a wall switch. The distance between the control unit and the CAS should be no more than 1,000 feet. If you are installing the CAS within 14 feet of the control unit, plug one end of a 14-foot modular cord into the modular jack on the front of the SMDR Module (Figure 4). Proceed to Step 4 below. 4

14-ft modular cord Control unit Printer SMDR Module in slot 5 Printer's RS-232 connector 355AF adapter Power supply Figure 4 CAS Installation 14 Feet or Less From the Control Unit 3. If you are installing the CAS more than 14 feet from the control unit, follow the instructions below: Install wiring from the SMDR Module in the control unit to the location of the CAS in the same manner that you installed it for your voice terminals. Refer to the installation guide you received with your communications system. Plug the loose end of the 4-pair modular jumper cord (not provided) from the jack field into the jack on the front of the SMDR Module (Figure 5). Plug one end of a 14-foot modular cord into the modular wall jack. Continue to Step 4 below. 5

Control unit 4-pair modular jumper cord Jack field SMDR module in slot 5 Cable (1,000 ft. maximum) 14-ft. modular cord Modular wall jack Printer's RS232 connector Printer 355AF adapter Power supply Figure 5 CAS Installation 15 Feet to 1,000 Feet From the Control Unit 4. 5. Plug the other end of the modular cord into the modular jack on the 355AF adapter. Connect the female connector on the 355AF adapter to the 25-pin male connector labeled SMDR on the back of the CAS (Figure 6). Tighten the screws. 6

355AF adapter Printer 14-Ft. modular cord (Back view) Figure 6 Connecting the Control Unit and Printer to the CAS 6. 7. 8. Connect your printer's 25-pin male connector to the female connector labeled Printer on the back of the CAS (Figure 6). Tighten the screws. NOTE: Make sure that your printer's baud rate is set at 1200. If you are not able to adjust your printer s baud rate to 1200, refer to the section of this document titled "Changing the Baud Rate of the CAS s Output." Plug the CAS's power supply into a 3-prong power outlet that is not controlled by a wall switch. The green light labeled Power goes on. Insert your custom cartridge into the cartridge slot on the front of the CAS (Figure 7). Push the cartridge slowly and steadily until it is firmly in place. The red light labeled Ready goes on. If your printer s ac power cord is plugged in and its power switch is set to the on position, a system diagnostics message is printed. If a system diagnostics message is not printed and all the conditions listed above have been met, refer to this document s section titled Troubleshooting Procedures. 7

Cartridge slot Red Light Green light Custom cartridge Figure 7 Installing Your Custom Cartridge System Options There are five system options which are set using switches located inside the CAS. The following is a list of system options, their definitions, value ranges, and preset values. Refer to this list to determine if the preset values of the system options meet the needs of your business. If you need to change one or more of the values to meet the unique needs of your business, follow the instructions below the list; otherwise, continue to the next section titled "Testing Procedures." Value Preset System Option Definition Range Value Percentage Increases the recorded 0-99% 0 markup: cost of outgoing calls by a specified percentage Line spacing: Adjusts the number of 0-31 lines 0 blank lines between call records Suppress records Prevents the printing of call Yes or No for incoming calls: records for incoming calls on the chronological report No Suppress records Prevents the printing of call Yes or No No for local calls: records for local calls on the chronological report Suppress records Prevents the printing of call Yes or No No for calls without records for calls without account numbers: amount numbers on the chronological report 8

SETTING SYSTEM OPTIONS WARNING: Before setting system options, unplug the CAS's ac power cord from its outlet. 1. 2. 3. Turn the CAS upside down and remove the four screws from each corner and set them aside. Turn the CAS right side up and lift the cover off. Position the CAS so that the cartridge and/or cartridge slot is on the right side (Figure 8). Switch Box 1 Switch Box 2 Switch Box 3 Cartridge Figure 8 Positioning the CAS and Locating System Option Switch Boxes 4. 5. Locate the red switch boxes above the ac power cord inside the CAS (Figure 8). Follow the instructions below if it is necessary to change system options. PERCENTAGE MARKUP Switch Box 1 (Figure 9) is used to set the Percentage Markup and is divided into two sides. Side A represents the first digit of the percentage markup and Side B represents the second digit. In order for you to determine which switches to set, follow the instructions below. 9

Side A Side B 1 2 3 4 5 6 7 8 Switch box 1 Figure 9 Setting the Percentage Markup Option Switches 1. Write the percentage markup you are assigning to your system to the right of the example. NOTE: If the percentage you are setting contains a zero (0), it is not necessary to set any switches. All switches on the side of the switch box containing the zero should be in the up position Example (25%) 2 5% First ( Digit) ( Second Digit ) ( First Digit) ( Second Digit ) 2. Locate the first digit of the percentage you want to set on the table below. First Digit of the Percentage 1 2 3 4 5 6 7 8 9 Switch Number 1 2 1+2 3 1+3 2+3 1+2+3 4 1+4 3. Write the switch numbers that are next to the first digit of the percentage that you selected from the table 2 10

4. Using the table below, locate the second digit of the percentage you want to set. Second Digit of the Percentage 1 2 3 4 5 6 7 8 9 Switch Number 5 6 5+6 7 5+7 6+7 5+6+7 8 5+8 5. 6. 7. Write the switch numbers that are next to the second digit of the percentage that you selected from the table. Repeat your answers from questions 3 and 5 here. Slide the numbered switches that you marked in Step 6 down on Switch Box 1. All other switches should be in the up position. 5+7 2 5+7 Side A Side B Side A Side B 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 If you want to set other system options, continue following the instructions below. Otherwise, skip to the section titled "Replacing the CAS s Cover." LINE SPACING Switch Box 2 (Figure 10) is used to set line spacing, suppress records for incoming calls, local calls, and calls without account numbers. The switch box is divided into two sides. Side A is used to adjust the number of blank Iines between call records. Side B is used to set the remaining system options. Follow the instructions below to set the number of blank lines between call records. Side A Side B 1 2 3 4 5 6 7 8 Switch box 2 Figure 10 Setting the Line Spacing Option Switches 11

1. 2. 3. Locate the number of blank lines that you want to leave between call records on the table below. NOTE: If you do not want any blank lines between call records, it is not necessary to set any switches. All switches on Side A of Switch Box 2 should be in the up position. Number of Switch Number of Switch Blank Lines Numbers Blank Lines Numbers 1 1 16 5 2 2 17 1+5 3 1+2 18 2+5 4 3 19 1+2+5 5 1+3 20 3+5 6 2+3 21 1+3+5 7 1+2+3 22 2+3+5 8 4 23 1+2+3+5 9 1+4 24 4+5 10 2+4 25 1+4+5 11 1+2+4 28 2+4+5 12 3+4 27 1+2+4+5 13 1+3+4 28 3+4+5 14 2+3+4 29 1+3+4+5 15 1+2+3+4 30 2+3+4+5 31 1+2+3+4+5 Locate the switch numbers that are next to the number of blank lines you selected on the table. Slide these switch numbers down on Side A of Switch Box 2 (Figure 10). Examples To set 3 blank lines between call records, slide the switches numbered 1 and 2 down on Side A of Switch Box 2. To set 4 blank lines between call records, slide the switch numbered 3 down on Side A of Switch Box 2. If you want to set other system options, continue following the instructions below. Otherwise, skip to the section titled "Replacing the CAS s Cover." 12

SUPPRESSING RECORDS FOR INCOMING CALLS, LOCAL CALLS, AND CALLS WITHOUT ACCOUNT NUMBERS Side B of Switch Box 2 (Figure 11) is used to suppress the printing of records for incoming calls, local calls, and calls without account numbers on the chronological report. Even though local call records and calls without account numbers are suppressed from the chronological report, information about these calls will be included in the summary reports. Follow the instructions below to set these system options. Side A Side B Switch box 2 1 2 3 4 5 6 7 8 Figure 11 Setting the Remaining System Options 1. Locate the system option(s) you want to set on the table below. System Option Switch Number Suppress records for incoming calls 6 Suppress records for local calls 7 Suppress records for calls without account numbers 8 2. Slide the switch number upon Side B of Switch Box 2 for the option(s) to be suppressed (Figure 11). Example To suppress records for incoming calls, slide switch number 6 up on Side B of Switch Box 2. CHANGING THE BAUD RATE OF THE CAS S OUTPUT The data transmission speed (baud rate) of the CAS s output is preset to 1200 bits per second. If your printer s baud rate is not set to 1200 1 and you are unable to change its baud rate to 1200, you will have to change the CAS s output baud rate to the same speed as your printer s baud rate. Follow the instructions below to change the baud rate of the CAS s output by setting Switch Box 3 (Figure 12). NOTE: Switch numbers 5, 6, and 7 are used when adjusting the baud rate. If you accidentally move one of the other switches (1 through 4) in Switch Box 3, refer to Figure 12 for their proper settings. 13

Switch box 3 1 2 3 4 5 6 7 Figure 12 1200 Baud Rate Switch Settings 1. Remove the CAS s cover by following Steps 1 through 5 in the section of this document titled Setting System Options. 2. To change the baud rate to 300, slide switch number 5 up and switch number 7 down (switch number 6 remains down) on Switch Box 3. 3. To change the baud rate to 600, slide switch number 6 up and switch number 7 down (switch number 5 remains down) on Switch Box 3. 4. Replace the CAS's cover following the instructions in the section below. REPLACING THE CAS s COVER 1. Position the base of the CAS so its front is facing you. 2. Hold the cover so that it is right side up and the ventilation slots are at the back of the unit (Figure 13). Cover Ventilation slots Base Figure 13 Replacing the Cover 14

3. 4. 5. 6. Align the cover s grooves with the unit s front and back plates. Push down on the cover until it is securely in place. Turn the CAS upside down and insert the screws, that you previously set aside, into the four screw holes. Tighten the screws. Turn the CAS right side up. Plug its power supply into a 3-prong ac power outlet. Testing Procedures Now that your CAS is installed, you need to test it to make sure that it is operating properly. The following tests will help you determine if you have installed your CAS correctly. If these tests reveal any problems, refer to the section titled "Troubleshooting Tables." SYSTEM DIAGNOSTICS MESSAGE The system diagnostics message contains information that will help you verify system options that you may have set. To generate a system diagnostics message (Figure 14), follow the instructions below. 053084.201834 212516.609213 F0ATT0.F8ATT0 E0ATT0.E8ATT0 00.00 00.50 00.00 00.50 00.00 00.00 00 0.0 00 19 D D D D D 60 08 00 17 40 23 60 Figure 14 Example of a System Diagnostics Message 1. Make sure that your printer has been installed and is properly functioning according to its manufacturer s instructions. Refer to the manual supplied with your printer. 2. Make sure that the printer's ac power cord is plugged in and that its power switch is set to the on position. If your printer has a ready button, make sure it is on. 3. Remove and reinsert the cartridge into the CAS's catridge slot. The red light labeled Ready goes off and then on. A system diagnostics message is printed. 4. Verify each system option that you may have set (Figure 14). If a system diagnostics message is not printed, refer to the section titled Troubleshooting Tables. 15

A system diagnostics message is also printed after power is restored following a power Ioss (brown out, black out, or a drop in voltage). In these instances, this message indicates loss of memory in the CAS. Call records printed prior to the power Ioss are not included in the summary reports. CALL RECORD VERIFICATION To verify that your CAS is receiving information from your communications system and producing call records (Figure 15), follow the steps Iisted below. 08:22 14544466 NJ 001 $00.42 01 Figure 15 Telephone Call Record 1. Place an outside call of at least one minute in duration. 2. Hang up your handset. A telephone call record of your call is printed. If any other telephone calls are completed during this procedure, additional telephone call records appear on the printout. If no call record appears, skip to this document s section titled "Troubleshooting Procedures." 16

Reports The CAS produces chronological and summary reports which provide information about the telephone call activity in your business. The reports are produced automatically and contain details about incoming calls and calls made to outside numbers. By setting system options it is possible to suppress records of incoming calls, calls made to local numbers, and calls without account numbers from appearing on the chronological report. If it is necessary for you to set system options and you have not already done so, refer to the section of this document titled "System Options." NOTES: Your communications system allows you to enter account numbers up to 16 digits in length when a call is made. Only the first 9 digits of each account number is printed on the chronological report and summary reports. The CAS calculates the cost of all telephone calls made to outside numbers according to Direct Distance Dialing (DDD) rates. Calls made at DDD rates cost slightly more than calls made at message unit rates. If your local calls are charged to you at message unit rates by your telephone company, the reports produced by the CAS will contain slightly inflated cost information. CHRONOLOGICAL REPORT The Chronological Report (Figure 16) is a list of all incoming and outgoing call records. Each call record is printed at the completion of the call. Date Time Extension Number Dialed Location Duration Cost Account Number Line# 08:22 08:45 09:23 09:27 09:37 09:47 10:12 10:22 10:45 11:23 11:25 11:27 11:35 12:07 12:12 12:25 13:01 13:21 13:37 13:41 14544466 18004312020 14137651000 02128885555 19878989 7331275 15551212 12035551212 14154315154 14137651000 02128885555 7388928 7331275 15551212 0114466825 8901024 17168901064 17168901011 NJ TF MA OP NJ NJ I N I N CA MA OP NJ NJ I N OV NJ NY NY 001 011 006 037 032 010 001 001 001 006 027 042 006 007 001 013 010 021 008 001 $00.42 $00.00 $02.39 $00.00 $03.97 $01.12 $00.50 $00.50 $00.69 $02.39 $00.00 $02.56 $00.72 $00.00 $00.50 $11.05 $00.99 $00.00 $03.13 $00.54 1567890 219581985 5678 123 1238 5678 1256 567890 9581985 5678 5678 567890 56 567789 01 02 03 07 25 30 00 01 02 03 07 25 30 30 00 00 01 04 10 14 Figure 16 Chronological Report 17

Each call record includes a two-character location abbreviation for the state to which a call is made. These state abbreviations correspond to the state abbreviations used by the United States Post Office. The following table lists the abbreviations which are used in addition to the state abbreviations. Abbreviation AB BC IS MB NB NF NS ON OP OV PQ SK SP TF Alberta (Providence of Canada) Type/Destination of Call British Columbia (Providence of Canada) Bahama Bermuda Virgin Islands Manitoba (Providence of Canada) New Brunswick (Providence of Canada) New Foundland (Providence of Canada) Nova Scotia (Providence of Canada) Ontario (Providence of Canada) Operator Assisted Overseas Quebec (Providence of Canada) Saskatchewan (Providence of Canada) Special (900 numbers) Toll-free (800 numbers) SUMMARY REPORTS There are four summary reports produced after the CAS processes a call record with a new date. After the last summary report is printed, call records received while the summary reports were printing are listed on the chronological report. The following are samples of the summary reports. NOTE: The date the summary reports are printed appears in the reports' headings. 18

Summary of Calls by Hour of the Day: SUMMARY BY HOUR 12/12 HOUR CALLS DURATION COST 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 0003 0004 0003 0004 0003 0004 23 85 03 81 21 40.92 0007.48.69 0005.67 0011.55 0004.66 Summary of Calls by Line Number: SUMMARY BY LINE# 12/12 LINE CALLS DURATION COST 00 01 02 03 04 07 10 11 14 20 25 30 0003 0003 0002 0002 0002 0002 0002 05 02 02 02 21 64 08 01 00 07 74 06 0012.05.91.69 0004.78 0003.13.50.54 0006.53.84 19

Summary of Calls by Extension Number: SUMMARY BY EXTENSION 12/12 EXT. CALLS DURATION COST 0007 0006 0008 95 95 63 0012.23 0004.13 0015.61 TOT CALLS DURATION COST 21 0253 31.97 Summary of Calls by Account Number: SUMMARY BY ACCOUNT 12/12 ACCT CODE CALLS DURATION COST 56 123 1238 1256 5678 567789 567890 1567890 9581985 219581985 0005 0002 00 37 32 00 39 00 08 00 00 01.50 0003.97.50 0007.12.54.50.42.69 TOT CALLS DURATION COST 0015 32 0014.24 20

Troubleshooting Tables Refer to the following table for solutions to possible problems you may encounter. The problem may be a user error, installation problem or faulty component. You should be able to correct the problem on the spot without returning equipment for maintenance exchange. If you cannot correct the problem, contact your equipment supplier. Symptom: A system diagnostics message is not printed. Possible Cause 1. There is no ac power. 2. The ac outlet is defective. 3. The printer connected to the CAS is not installed properly. 4. Connection between the CAS and the printer is faulty. Recommended 1. 2. 3. 4. Action Make sure the CAS or printer is not connected to an outlet controlled by a switch. Check the connections between the CAS and its ac power outlet and between the printer and its ac power outlet. Test the outlet by plugging in a lamp or radio. Test the outlet by plugging in a lamp or radio. Refer to the manufacturer's instructions for installation directions. If your printer has a ready button, make sure that it is on. Make sure the wiring between the CAS and the printer is not damaged. Make sure the connections are secure and that the screws on the connector are tightly fastened. Symptom: A system diagnostics message prints out in the middle of a chronological or summary report. Possible Cause Recommended Action There was a power loss (brown out, black out or drop in voltage). None. Call records printed prior to the power loss are not included in summary reports because of memory loss in the CAS. 21

Symptom: A call record is not printed. Possible Cause Recommended Action 1. Connection between the CAS and the 1. Make sure the wiring between the CAS control unit is faulty. and the control unit is not damaged. Make sure the connections are secure and that the screws on the connector are securely fastened. 2. The duration of the telephone call is not 2. None. more than one minute. 3. The SMDR options are not administered 3. Refer to your administration manual's correctly. section titled "Administering SMDR Options." Symptom: Unitelligible data appears on system reports. Possible Cause Your printer's baud rate is not set to the correct speed. or The CAS is not set to the same baud rate as your printer. Recommended Action Refer to the manufacturer's instructions received with your printer to set its baud rate to 1200. If this is not possible, refer to the section of this document titled "Changing the Baud Rate of the CAS's Output." Maintenance Information UPDATED CUSTOM CARTRIDGES The CAS does not require a special maintenance program. However, the tariff rates contained in the software of your custom cartridge are subject to change by the Federal Communications Commission (FCC). As the tariff rates that are charged to you by your telephone company change, updated custom cartridges containing the new tariff rate information may be ordered. Refer to the following section for ordering information. ORDERING INFORMATION Customized cartridges (Order Number 31671) for the CAS containing updated tariff rates are orderable by calling the AT&T National Sales Part Center s toll-free number, 1-800-222-PART. 22

WARRANTY INFORMATION Other Important Information AT&T warrants that this product will be free from defects in material and workmanship on the date of your purchase, and that it will repair or replace, at its option, without charge for parts or labor, the product if it fails to work, provided that the defect is reported to AT&T within one year of your purchase. If AT&T determines that any defective product cannot be replaced, it may refund your purchase price. Replacement parts or products may be new or equivalent to new in performance, and will be provided on an exchange basis. You will be responsible for delivering a defective product to a designated repair location. For information on repair procedures, call your authorized dealer. The warranties provided in this section do not cover damages, defects, malfunctions or product failures caused by: Failure to follow AT&T s installation, operation or maintenance instructions. Modification of the product. Abuse, misuse or negligent acts by persons other than AT&T. Power failures or surges, fire, flood, accident, actions of third parties and other events outside AT&T s control. Except as specifically made in this agreement, AT&T and its affiliated subcontractors and agents make no warranties, expressed or implied, and specifically disclaim any warranty of merchantability or fitness for a particular purpose. In no event will AT&T or its dealer be liable for any claims, suits, liabilities, damages, costs or expenses in excess of $50,000.00 regardless of the form of action, whether in contract, tort (including negligence) and strict liability or otherwise, and whether or not foreseeable, except for direct damages for personal injury (including death). In no event will AT&Tor its dealer by liable for indirect, special reliance, incidental or consequential loss or damage arising out of the subject matter of this agreement. INTERFERENCE INFORMATION WARNING: Federal Communications Commission (FCC) Rules requires that you be notified of the following: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. 23

The equipment has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. SPECIFICATION TABLE Specifications Extension capacity: Dialed number capacity: 4 digits 10 digits Access number: 1 Line capacity: 49 lines (1-49) Station capacity: 120 stations (0-119) Account code print capacity: Traffic capacity: Costing methods: 9 digits 600 calls per day Direct Distance Dialing (DDD) Costing table: Percentage markup multiplier: 0-99% contained in custom cartidge Interface: Input port: Output port: Station Message Detail Recording (SMDR) Module 1200 baud 300, 600, or 1200 baud Extension summary capacity: 100 extensions (0-99) Account code summary capacity: Reports: 200 account numbers chronological summary by hour of the day by line number by extension number by account number Dimensions: 10" by 7" by 3" 24

AT&T Issue 1 Copyright 1985 AT&T Printed in U.S.A.