The Chan-L-Wire Pro Series Lighting Distribution

Similar documents
The Uniduct Nonmetallic Latching Raceway

lumenalpha spot Specification Sheet

5400 Series Nonmetallic Raceway

Church Layout Medium Advanced

WLB SERIES HID Lighting for Hose Down Applications

XML LED X M L L E D. Explosionproof Linear LED Lighting

Fiberglass - Technical Data

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

Illustrated Feature. Options

Safety Codes Council Conference Banff C Panel Discussion

Center For The Arts Towson, Maryland

IndyGo Facility Upgrades Project 35671EE

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

Clarity Advanced Solutions6A

Wire Connectors FAX WIRE CONNECTORS. Quick, reliable splices are a snap and a squeeze

Model Material Lamp type LED color Voltage Distribution Lens

Small Circular Connector. JN1W / JN2W Series

Modular Lube Lubrication Systems System Controls

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by:

Small System Packages. Strand Dimming Systems

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Table of Contents/Quality and Reliability

Continuous High-Flex Cable for Automated Systems

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Channel Cable Tray - Accessories

BROCHURE NEW 10 AWG MODULAR WIRING SYSTEM FOR LIGHTING. Suspended Ceiling and High & Low Bay Lighting Applications A PART OF

ICS Digital Menu. Installation Guide Version 1.1

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

FLUID VIEW 12V LED TAPE LIGHT

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

EXLUX ECOLUX 6480 Series

AS09..S 3-pole Contactors - Spring Terminals

Small System Packages. Strand Dimming Systems

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

DIN Power Module - Phase Adaptive

Student Services & Classroom Addition

NEW! Wide Area Lighting - Rough Service Fluorescent. MULTIVOLTAGE Automatically Operates at 120 to 277 VAC 50 or 60 Hz *1142 only

VITALink Taped Splice Straight Through Crimp

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

WFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations

BROCHURE MC LUMINARY CABLES

INSTALLATION INSTRUCTIONS FOR

Installation Manual SaVi Note Underwater LED Light

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

EXLUX ECOLUX C-LUX 6480 Series

WaveTrax. Fiber Cable Management System

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

Pauluhn Apex. Linear, high bay LED luminaires designed for harsh & heavy industrial applications

Cable ISOBUS Active Termination

Lumencove Family. The highest quality light from the tightest spaces

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

Power and Cable Management Products Doorbells Digital Tester

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Single Point Flow Monitor SW118 SW119

SQM40/41 Actuators for air and gas dampers

Follow The Leader In Shielded Technology

Directional Couplers and Splitters

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

SPECIFICATION SHEET lumencove

Scotchlok Connectors and Tools

TeamWork Kits Installation Guide

Continuous Currents. When inspectors see a photovoltaic (PV) power system. through Curious Cables. by John Wiles

SPECTRUM. cordgrip connectors AMERICAN FITTINGS. SPEC-grade. Corporation 1/2 to 2. Made in the USA. Put a Little Color on Your Cords

LED MODULES READYLINE DL

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

Flexible Cord. Inside this section

Process Transmitter RMA 422

3 Cold Shrink Products

Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs!

SITE All work shall be performed at Center Park Substation (1895 Kernan Blvd, Jacksonville, Fl ). DATE: 04/03/2018

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Distributed Design Series

RT AUDIO RETRACTABLE CABLE

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

System 500. Non-fire-rated, mineral insulated copper sheathed wiring cable

Bravo AV s Structured or Whole-House Wiring Approach

Data Sheet Definite Purpose Contactors Ex9CK Series

PARTS LIST FOR CM-1250-A/C 1.5 HP

TOKISTAR. TokiLux TOKISTAR LIGHTING

Sign Illuminating Ballasts

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

Bulletin 190 IEC Modular Starter System

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

PowPak Dimming Module with 0 10 V- Control

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

PROJECT DATE LENS SF FLANGE FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

AMERICAN NATIONAL STANDARD

Small Circular Connector. JN1/JN2 Series. Dust Cap

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

HYDROLUME LED STRIP LIGHT

Non Magnetic Connectors

Figure 1: Device components

I/A Series Hardware Fiber Optic LAN Converter

LED FLAT PANEL. Surprisingly simple. Significant savings. INNOVATION. SIMPLIFIED.

INVISILED ACCESSORIES

Transcription:

Lighting Distribution System Offers Maximum Flexibility The Chan-L-Wire Pro Series Lighting Distribution System offers maximum flexibility while saving up to 40% in labor installation costs. The system supports and powers all types of lighting, small appliances or small power loads in open ceilings utilizing galvanized steel channel and 277/480V or 120/208V cables. Quick Tap connectors with or without cord-ends and loops displace the cable insulation and support the lighting fixtures. The flexibility of the Chan-L-Wire System also allows fixtures to be moved or added in the future, therefore, reducing the high costs associated with last minute design changes, building renovations and fixture maintenance. The examples listed within this manual are meant to apply the Chan-L-Wire solution to many of today s most common lighting applications. However, many more applications are possible using Chan-L-Wire components. If information is required on a particular application which is not listed, a local Wiremold / Legrand representative should be contacted for assistance. Chan-L-Wire Pro Series Lighting System Universal Quick Tap with a fixture hanger. Completely prewired components. Installation labor savings. Galvanized steel channel. Compatible with all types of light fixtures. Fixtures can be positioned or relocated anywhere along the channel. Unlimited system flexibility. Unique 5-wire flat cables each with a continuous ground conductor identified by a green stripe. Separate cables rated for 277/480V, 347/600V and 120/208V 3-phase, 5-wire service. Features All flat cable conductors are #10 gauge stranded wire. Feed taps rated for 30 Amp @ 277/480V, 347/600V and 120/208V with 3/4" [19.1mm] hub. 20 Amp, 5-wire 277/480V, 347/600V and 120/208V Quick Tap connectors and fixture hangers with 1/2" or 3/4" [12.7mm or 19.1mm] hub. 15 Amp, 277V, 347V and 120V cord-ended Quick Tap and locking-type receptacle with/ without loop. 20 Amp, 3-wire 120V Quick Tap fan tap connector with mounting box. culus Listed. Sold by: http://www.twacomm.com Toll Free: (877) 389-0000 ED1459R1 Updated June 2006 For latest specs visit www.wiremold.com

Chan-L-Wire Pro Series System Layout G C F D E B A C H I F E B NOTE: Illustration is for product applications and may not represent proper circuit wiring. A T30 Feed Tap (Junction Box By Others) B CLWH Channel Hanger (Threaded Rod By Others) C T277/T120 Quick Tap Series Taps & Fixture Hangers (1/2 or 3/4" [12.7mm or 19.1mm] Hub) D CLWC Channel Coupling E TCE277/ TCE125 Quick Tap Series Cord-Ended Tap & Locking-Type Receptacle With Closed Loop F CLWECPR End Cap/ Cable Puller G CLWFC120/ 277 Flat Cable H CLWS Channel I TC277/TC125 Quick Tap Series Cord-Ended Tap & Locking-Type Receptacle Chan-L-Wire Pro Series Installation Procedures Step 1. Put up the channel. Step 2. Feed the cable. Step 3. Mount the tap. Step 4. Hang fixture and energize. It s that easy. 2

Chan-L-Wire Pro Series System Components BASIC SYSTEM COMPONENTS Required for each project CHANNEL Supports cable and fixture or fan taps 16 gauge galvanized steel Roll formed with integral bead to support flat cable Available in 10 & 20 [3m & 6.1m] foot lengths CABLE Delivers up to 30 Amp service Provides 3-phase, 5-wire service (3 phase, 1 Neutral, 1 Ground) enclosed in U.L. Listed PVC insulating material Supplies power to fixtures via Quick Taps Separate cables rated for 120/208V and 277/480V, 347/600V at 75 Centigrade Easy pull through flat cable with continuous ground conductor (identified by a green stripe) Capable of withstanding U.L. ground fault current testing of 10,000 Amps 10 gauge stranded wire conductors reduce the effects of harmonics and increase heat dissipation in unbalanced load conditions Phase conductors marked with Phase A, B, or C on the conductor Available in 200 foot or 1000 foot [61m or 305m] reels CHANNEL COUPLING Couples two lengths of channel Galvanized steel CHANNEL HANGER Suspends channel Support with 3/8" [9.5mm] threaded rod (supplied by others) Galvanized steel END CAP/ PULLER Attaches cable to a pull rope for ease of installation Remains in place for cable termination at both ends of run Packaged in pairs (need one for each end of run or one pair per run) CABLE PULL-IN GUIDE Guides cable into channel during pulling Typically need one for small jobs and two or more for large projects Feed Tap Use one per run to provide connection of home run to electrical load Rated for 30 Amp service Separate taps rated for 120/208V, 277/480V and 347/600V Five #10 AWG pigtails 9" [229mm] long 3/4" [19.1mm] hub with locknut to allow for attachment of industry standard junction box (provided by others) 3

Chan-L-Wire Pro Series System Components FIXTURE INSTALLATION COMPONENTS Method varies based on individual project requirements UNIVERSAL QUICK TAP WITH FIXTURE HANGER Introduces power to lighting fixture by means of five #12 THHN wire leads 9", 18" or 36" [229mm, 457mm, or 914mm] standard Phase can be selected in the field Contacts appropriate phase, neutral and ground of cable to provide 20 Amp service Separate taps rated for 120/208V, 277/480V and 347/600V Can be mounted to fixture at floor level Available with 1/2" or 3/4" [12.7mm or 19.1mm] NPT hub May be moved for fixture maintenance or fixture layout redesign Need one per fixture CORD-ENDED QUICK TAP WITH LOCKING-TYPE RECEPTACLE Connects cordset equipped lighting fixtures Tap prewired to 9" [229mm] 14/3 cordset with locking-type NEMA L7-15R or NEMA L5-15R connector (Cordset lengths longer than standard 9" [229mm] available on made-to-order basis) Separate taps rated for 120V, 277V and 347V Contacts appropriate phase, neutral and ground of cable to provide 15 Amp service Need one per fixture CORD ENDED QUICK TAP WITH LOCKING-TYPE RECEPTACLE AND CLOSED LOOP Connects cordset equipped lighting fixtures Tap prewired to 9" [229mm] 14/3 cordset with locking-type NEMA L7-15R or NEMA L5-15R connector Separate taps rated for 120V, 277V and 347V Contacts appropriate phase, neutral and ground of cable to provide 15 Amp service Includes a closed loop Need one per fixture FIXTURE HANGER Supports the end of fluorescent fixture opposite the fixture tap Available with 1/2" or 3/4" [12.7mm or 19.1mm] hub QUICK TAP FAN TAP WITH MOUNTING BOX Introduces AC power to fan by means of three #12 THHN wire leads 9" [229mm] standard Contacts appropriate phase, neutral and ground of cable to provide 20 Amp service Rated for 120V Includes mounting box May be moved for fan maintenance or layout redesign Need one per fan 4

Chan-L-Wire Pro Series System Ordering Information CABLE CLWFC277 1000' [305m] Reel, 277/480V 1000 ft. CLWFC277-200 200' [61m] Reel, 277/480V 200 ft. CLWFC120 1000' [305m] Reel, 120/208V 1000 ft. CLWFC120-200 200' [61m] Reel, 120/208V 200 ft. CHANNEL CLWS-10 10' [3.05m] Length 20 ft. CLWS-20 20' [6.1m] Length 40 ft. COUPLING CLWC Coupling 1 CHANNEL HANGER CLWH Hanger 1 END CAP/ CABLE PULLER FIXTURE HANGERS CLWFH75 3/4" [19.1mm] 1 CLWFH50 1/2" [12.7mm] 1 FEED TAPS T30-277 277/480V, 30 Amp Rated 1 T30-120 120/208V, 30 Amp Rated 1 CORD-ENDED QUICK TAPS WITH LOCKING-TYPE RECEPTACLE (15 Amp Rated) CATALOG NO. PHASE DESCRIPTION PKG. QTY. TC277A A 9" [229mm] Cordset, 277V 1 TC277B B 9" [229mm] Cordset, 277V 1 TC277C C 9" [229mm] Cordset, 277V 1 TC125A A 9" [229mm] Cordset, 120V 1 TC125B B 9" [229mm] Cordset, 120V 1 TC125C C 9" [229mm] Cordset, 120V 1 NOTE: Cordset lengths longer than the standard 9 inches [229mm] are available on a made-to-order basis. CLWECPR End Cap/ Puller 1 Pair CABLE PULL-IN GUIDE 615CLWA Guide 1 UNIVERSAL QUICK TAPS WITH FIXTURE HANGERS (20 Amp Rated) CATALOG NO. PHASE DESCRIPTION PKG. QTY. T277ABC75 A,B or C 3/4" [19.1mm] Hub, 9" [229mm] Leads, 277/480V 1 T120ABC75 A,B or C 3/4" [19.1mm] Hub, 9" [229mm] Leads, 120/208V 1 T277ABC75-18 A,B or C 3/4" [19.1mm] Hub, 18" [457mm] Leads, 277/480V 1 T120ABC75-18 A,B or C 3/4" [19.1mm] Hub, 18" [457mm] Leads, 120/208V 1 T277ABC75-36 A,B or C 3/4" [19.1mm] Hub, 36" [914mm] Leads, 277/480V 1 T120ABC75-36 A,B or C 3/4" [19.1mm] Hub, 36" [914mm] Leads, 120/208V 1 T277ABC50 A,B or C 1/2" [12.7mm] Hub, 9" [229mm] Leads, 277/480V 1 T120ABC50 A,B or C 1/2" [12.7mm] Hub, 9" [229mm] Leads, 120/208V 1 T277ABC50-18 A,B or C 1/2" [12.7mm] Hub, 18" [457mm] Leads, 277/480V 1 T120ABC50-18 A,B or C 1/2" [12.7mm] Hub, 18" [457mm] Leads, 120/208V 1 T277ABC50-36 A,B or C 1/2" [12.7mm] Hub, 36" [914mm] Leads, 277/480V 1 T120ABC50-36 A,B or C 1/2" [12.7mm] Hub, 36" [914mm] Leads, 120/208V 1 NOTE: 120V Taps can be used for 208V applications. 277V Taps can be used for 480V applications. 5

Chan-L-Wire Pro Series System Ordering Information (continued) CORD-ENDED QUICK TAPS WITH LOCKING-TYPE RECEPTACLE & CLOSED LOOP (15 Amp Rated) CATALOG NO. PHASE DESCRIPTION PKG. QTY. TCE277A A 9" [229mm] Cordset, 277V 1 TCE277B B 9" [229mm] Cordset, 277V 1 TCE277C C 9" [229mm] Cordset, 277V 1 TCE125A A 9" [229mm] Cordset, 120V 1 TCE125B B 9" [229mm] Cordset, 120V 1 TCE125C C 9" [229mm] Cordset, 120V 1 QUICK TAP FAN TAPS WITH MOUNTING BOX (20 Amp Rated) CATALOG NO. PHASE DESCRIPTION PKG. QTY. TF120A A 9" [229mm] Leads, 120V 1 TF120B B 9" [229mm] Leads, 120V 1 TF120C C 9" [229mm] Leads, 120V 1 TABLE 1 Fixture Tap & Cable Alignments CLWFC277 277/480V Cable CLWFC120 120/208V Cable NGABC NG ABC NGABC NG ABC T277ABC50 T277ABC75 T120ABC50 T120ABC75 TABLE 2 Channel Loading Conditions Channel Span Mid-Span Max Load (lbs.) Deflection Inches [m] Inches [mm] 60 [1.5] 100 0.13 [3.3] 72 [1.8] 84 0.19 [4.8] 84 [2.1] 72 0.26 [6.6] 96 [2.4] 63 0.33 [8.4] 108 [2.7] 56 0.42 [10.7] 120 [3.0] 45 0.50 [12.7] NOTE: For hanger spans up to 10 feet, fixtures or fans must be a minimum of 12 inches from centerline of coupling. 6

Chan-L-Wire Pro Series Power Drop Application 7

Chan-L-Wire Pro Series Frequently Asked Questions 1. Can CLW be used in power drop applications? Yes, for light or low amperage draw applications only. Remember this is not a bus bar system. A perfect application would be on an assembly line that uses hand held power tools. It has also been used to power sewing machines in fabric assembly plants. It s great for places that relocate equipment often. 2. How do you feed a CLW run of channel? The T30-277 or T30-120 Feed Taps can be positioned anywhere along a CLW run for termination. The most common method is to mount a 4 1/16" square utility box to the Feed Tap and bring the feeder power through conduit into the box. 3. Can you run emergency lighting and regular lighting on the same CLW run? The answer really is no if you are talking about true emergency lighting or power. Article 700 of the NEC simply states that emergency power can not occupy the same raceway as normal power. Often emergency power is associated with standby power. Now, if we are talking about standby or optional standby as defined in Articles 701 & 702 the answer is, yes. One must understand the differences between emergency vs. standby. Simply put, emergency is defined as essential for safety to human life. In our case, egress lighting would be covered under emergency lighting. Standby covers non-life-supporting requirements. A good example would be lighting which has stopped during any interruption of the normal electrical supply and could create a hazard to operations. 4. Can you have emergency lighting on one phase of the CLW run and regular lighting on another phase? The answer here again is no if the circuit is true emergency lighting as covered under Article 700. However, the answer is yes if the circuits in question are covered under Articles 701 or 702. Again, refer to question number 3 above. 5. How do you connect the same run of CLW around an obstruction? The best way is to jump across two feed taps. Use two feed taps with junction boxes at the ends of the cable and channel runs. Connect between the boxes using flex conduit. This method would also be used to splice two cable lengths together on a straight run. Remember to use end caps at both ends of each of the runs. 6. Can you use CLW in damp location areas? No! The product is listed for dry location only as covered in Article 322 of the National Electrical Code. Example: It can t be used in a greenhouse or freezer room. 7. Can you paint CLW and will it affect the cable? CLW channel and channel couplings can be painted. The clamp assembly on the taps should not be painted. We have never experienced a failure of cable resulting from painting. However, we do not recommend painting the cable. We don t paint the product ourselves because the paint finish will not hold up during shipping. 8. What is the maximum length run of CLW? The general rule of thumb is 300 feet. After 300 feet the cable pulling resistance becomes very high and difficult to handle. There is also an electrical factor involved. One must consider the voltage drop based on length of run. As the amperage and voltage drop so will the allowable length of run. To add slightly more confusion, a balanced or unbalanced load will also affect voltage drop. This is all in accordance with Article 210-19(a) of the NEC. 9. Can I get cord-ended fixture taps with straight-blade receptacles instead of the locking-type receptacles? No. Straight-blade receptacles are not allowed by the NEC for ceiling applications. Sold by: http://www.twacomm.com Toll Free: (877) 389-0000 Wiremold / Legrand U.S. and International: 60 Woodlawn Street West Hartford, CT 06110 1-800-621-0049 FAX 860-232-2062 Outside U.S. 860-233-6251 Canada: 570 Applewood Crescent Vaughan, Ontario L4K 4B4 1-800-723-5175 FAX 905-738-9721 Copyright 2006 Wiremold / Legrand All Rights Reserved ED1459R1 Updated June 2006 For latest specs visit www.wiremold.com