Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Similar documents
Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Circuit breakers BZM. Circuit breakers BZM

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

High performance circuit breakers

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Bulletin 190 IEC Modular Starter System

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

MAINS DISTRIBUTION GUIDE

Series CT7N Bimetallic Overload Relays

Busbar Systems. Altech UL489. UL489 Listed Busbars. Universal UL489 Busbar fits most UL489 Miniature Circuit Breakers in the market!

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

XT IEC Power Control Combination Motor Controllers

POWER DISTRIBUTORS CRANE AND TUNNEL DISTRIBUTION CABINETS. socket (DIN 49440) 250V Output terminals. approx. Type Ord.no. kva kg

Power Circuit of a UL508A Panel. Typical UL489 Application

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

multi-function meters

AUTOMATIC TRANSFER SWITCHES. Product Guide

Circuit-Breakers for Motor Protection Series 8523/8

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

PRINCIPLES AND APPLICATIONS

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Altech UL489 Busbar System

EMC Solutions Noise filtering

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

llen-bradley 194R-HM4-NFPA3

Switching Power Module

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS AND BODIES COMMISSION

DIN Power Module - Phase Adaptive

Features XT SC 012 B B A

AS09..S 3-pole Contactors - Spring Terminals

Minicontactorrelay,2NO/2NC,DCoperated

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

Modular pulse operated latching relay 16 A

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

SURGE PROTECTIVE DEVICES

Features XT SC 012 B B A

TeSys circuit-breakers

Selection guide siemens.com/sirius-modular-system

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

8 Installation Equipment

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Schedule of Rate for Electrical Items Name of work:- Supplying of electrical items for day to day electrical maintenance work.

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

10 PDUs 19 PDUs Zero-U PDUs

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Contactors and Contactor Assemblies

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

PowerLogic power-monitoring units

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

GV2ME. Main. Device short name. Device application

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Accessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

Type: DILM25 10(24V50HZ) Article No.:

Gamma instabus. Technical product information

DMX and 4000 air circuit breakers from 800 to 4000 A

KRF EMC Filters Installation, Operation and Maintenance Manual

MIKRO POWER FACTOR CORRECTION COMPONENTS

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Type: DILM12 10(24VDC) Article No.:

C E R T I F I C A T E O F C O M P L I A N C E

GV2P05. Main. Device short name. Device application

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Identification - electrical services

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

For reference, here is a shop drawing of how feed through lugs is shown by a manufacturer:

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

Accessories. EasyPact and Vigi CVS100/160/ short LV long LV Steel connectors 1 x (1.5 to 95 mm²) ; y 160 A Set of 3 LV429242

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

Power and Cable Management Products Doorbells Digital Tester


MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

SPECIFICATION NO NOTE

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

PRELIMINARY Sunny Boy 240-US

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

Transcription:

Circuit Breakers BZM Product Information Circuit Breaker BZM1 16 to 125 A Circuit Breaker BZM2 125 to 250A BZM1 & BZM2 Accessories

Circuit breakers BZM1 3-pole Rated current Short circuit Basic switching Comfort switching Normal switching Strong switching = rated releases capacity 15kA capacity 18kA capacity 25kA capacity 36kA uninterrupted at 415 V 50/60 Hz at 415 V 50/60 Hz at 415 V 50/60 Hz at 415 V 50/60 Hz current I Part no. Part no. Part no. Part no. I n = I u A Article no. Article no. Article no. Article no. A 1 of each 1 of each 1 of each 1 of each Protection of systems and cables 3-pole Cable lug terminal 16 256-384 BZMD1-A16 BZME1-A16 BZMB1-A16 BZMC1-A16 109706 109707 109708 129978 20 256-384 BZMD1-A20 BZME1-A20 BZMB1-A20 BZMC1-A20 109709 109710 109711 129979 25 320-480 BZMD1-A25 BZME1-A25 BZMB1-A25 BZMC1-A25 109712 109713 109714 131250 32 320-480 BZMD1-A32 BZME1-A32 BZMB1-A32 BZMC1-A32 109715 109716 109717 131251 40 320-480 BZMD1-A40 BZME1-A40 BZMB1-A40 BZMC1-A40 109718 109719 109720 131252 50 480-720 BZMD1-A50 BZME1-A50 BZMB1-A50 BZMC1-A50 109721 109722 109723 131253 63 480-720 BZMD1-A63 BZME1-A63 BZMB1-A63 BZMC1-A63 109724 109725 109726 131254 80 800-1200 BZMD1-A80 BZME1-A80 BZMB1-A80 BZMC1-A80 109727 109728 109729 131255 100 800-1200 BZMD1-A100 BZME1-A100 BZMB1-A100 BZMC1-A100 109730 109731 109732 131256 125 800-1200 BZMD1-A125 BZME1-A125 BZMB1-A125 112490 112492 112495 Box terminal 16 256-384 BZMD1-A16-BT BZME1-A16-BT BZMB1-A16-BT BZMC1-A16-BT 109733 109734 109735 132913 20 256-384 BZMD1-A20-BT BZME1-A20-BT BZMB1-A20-BT BZMC1-A20-BT 109736 109737 109738 131257 25 320-480 BZMD1-A25-BT BZME1-A25-BT BZMB1-A25-BT BZMC1-A25-BT 109739 109740 109741 131258 32 320-480 BZMD1-A32-BT BZME1-A32-BT BZMB1-A32-BT BZMC1-A32-BT 109742 109743 109744 131259 40 320-480 BZMD1-A40-BT BZME1-A40-BT BZMB1-A40-BT BZMC1-A40-BT 109745 109746 109747 131260 50 480-720 BZMD1-A50-BT BZME1-A50-BT BZMB1-A50-BT BZMC1-A50-BT 109748 109749 109750 131261 63 480-720 BZMD1-A63-BT BZME1-A63-BT BZMB1-A63-BT BZMC1-A63-BT 109751 109752 109753 131262 80 800-1200 BZMD1-A80-BT BZME1-A80-BT BZMB1-A80-BT BZMC1-A80-BT 109754 109755 109756 131263 100 800-1200 BZMD1-A100-BT BZME1-A100-BT BZMB1-A100-BT BZMC1-A100-BT 109757 109758 109759 131264 125 800-1200 BZMD1-A125-BT BZME1-A125-BT BZMB1-A125-BT 112496 112498 112500 Note: 2 pieces phase barriers BZM1-XKP included in delivery 11

Circuit breakers BZM2 3-pole Rated current Short circuit Basic switching Comfort switching Normal switching Strong switching = rated releases capacity 15kA capacity 18kA capacity 25kA capacity 36kA uninterrupted at 415 V 50/60 Hz at 415 V 50/60 Hz at 415 V 50/60 Hz at 400 V 50/60 Hz current / I n = I u A Part no. Part no. Part no. Part no. A Article no. Article no. Article no. Article no. 1 of each 1 of each 1 of each 1 of each Protection of systems and cables 3-pole Cable lug terminal 125 1400-2100 BZMD2-A125 BZME2-A125 BZMB2-A125 BZMC2-A125 119730 119731 119732 121800 160 1400-2100 BZMB2-A160 BZMC2-A160 116970 121801 200 1400-2100 BZMB2-A200 BZMC2-A200 116971 121802 250 1400-2100 BZMB2-A250 BZMC2-A250 116972 121803 Note: 2 pieces phase barriers BZM2-XKP included in delivery 13

www.moeller.net Reliable Protection for systems, generators and motors up to 1600 A Product Information Circuit-Breakers NZM, Switch-Disconnectors PN/N

LV Power Distribution Memshield 2 DIN Miniature Circuit Breakers 1 The Eaton IEC DIN MCB range is manufactured in the United Kingdom at the Eaton Electric Birmingham facility. Compliant to IEC60898 Available in B, C and D curve characteristics, 10kA interrupting capacity. Fixed thermal calibrated to 40 C Approval No. 14928 18mm wide per pole. 6kA Curve C (5 ~ 10 x In) C Curve breakers are used in most general power distribution applications, such as lighting circuits and power sockets. Stock Code S 9Ampere 1 pole Price $ 2 pole Price $ 3 pole Price $ 4 pole Price $ Rating Cat. No. ex GST Cat. No. ex GST Cat. No. ex GST Cat. No. ex GST 10 MCL110 32.83 - - MCL310 138.88 - - 16 MCL116 32.83 - - MCL316 138.88 - - 20 MCL120 32.83 - - MCL320 138.88 - - 25 MCL125 32.83 - - MCL325 138.88 - - 32 MCL132 32.83 - - MCL332 138.88 - - 40 MCL140 32.83 - - MCL340 138.88 - - 50 MCL150 32.83 - - MCL350 138.88 - - 63 MCL163 32.83 - - MCL363 138.88 - - 10kA Curve C (5 ~ 10 x In) C Curve breakers are used in most general power distribution applications, such as lighting circuits and power sockets. Stock Code S Ampere 1 pole Rating Cat. No. Price $ ex GST 2 pole Cat. No. Price $ ex GST 3 pole Cat. No. Price $ ex GST 4 pole Cat. No. Price $ ex GST 1 MCH101 32.83 MCH201 108.32 MCH301 138.88 MCH401 198.18 2 MCH102 32.83 MCH202 108.32 MCH302 138.88 MCH402 198.18 4 MCH104 32.83 MCH204 108.32 MCH304 138.88 MCH404 198.18 6 MCH106 32.83 MCH206 108.32 MCH306 138.88 MCH406 198.18 10 MCH110 32.83 MCH210 108.32 MCH310 138.88 MCH410 198.18 16 MCH116 32.83 MCH216 108.32 MCH316 138.88 MCH416 198.18 20 MCH120 32.83 MCH220 108.32 MCH320 138.88 MCH420 198.18 25 MCH125 32.83 MCH225 108.32 MCH325 138.88 MCH425 198.18 32 MCH132 32.83 MCH232 108.32 MCH332 138.88 MCH432 198.18 40 MCH140 32.83 MCH240 108.32 MCH340 138.88 MCH440 198.18 50 MCH150 32.83 MCH250 108.32 MCH350 138.88 MCH450 198.18 63 MCH163 32.83 MCH263 108.32 MCH363 138.88 MCH463 198.18 All Prices Exclude GST 1-10 EATON CORPORATION LV Power Distribution Discount Schedule B16

Modular Circuit Protection Devices Miniature Circuit Breakers RCCBs - without overcurrent protection RCBOs - with overcurrent protection Switch Disconnectors (Isolators)

Protective Devices Table of Contents Protective Devices / Components RCD - Residual Current Devices (mrcm) 2 Add-on Residual Current Protection Unit (ASELM) 5 RCBO - Combined RCD/MCB Devices (mrbm) 7 RCBO - Electronic Combined RCD/MCB Devices (erbm) 12 MCB - Miniature Circuit Breakers (mmc) 14 MCB - Miniature Circuit Breakers for DC application (mmcmdc) 33 MCB - Miniature Circuit Breakers upto 125A (mmct) 35 Isolators 39 Fuse Devices 41 Surge Protection 44 Accessories for protective devices Technical Details 46 49 1

Residual Current Devices mrcm 2

Protective Devices Residual Current Devices mrcm Conditionally surge current-proof 250 A, type AC I n /I Δn (A) Type Designation Article No. Units per package wa_sg03810 2-pole 16/0.01 16/0.03 25/0.03 25/0.1 25/0.3 40/0.03 40/0.10 40/0.30 63/0.03 63/0.10 63/0.30 80/0.03 80/0.10 80/0.30 100/0.03 100/0.10 100/0.30 mrcm-16/2/001 158049 1/60 mrcm-16/2/003 142748 1/60 mrcm-25/2/003 142750 1/60 mrcm-25/2/01 142752 1/60 mrcm-25/2/03 142754 1/60 mrcm-40/2/003 142756 1/60 mrcm-40/2/01 142758 1/60 mrcm-40/2/03 142760 1/60 mrcm-63/2/003 142762 1/60 mrcm-63/2/01 142764 1/60 mrcm-63/2/03 142766 1/60 mrcm-80/2/003 142768 1/60 mrcm-80/2/01 142770 1/60 mrcm-80/2/03 142772 1/60 mrcm-100/2/003 142774 1/60 mrcm-100/2/01 142776 1/60 mrcm-100/2/03 142778 1/60 wa_sg03910 4-pole 25/0.03 25/0.1 25/0.3 40/0.03 40/0.10 40/0.30 63/0.03 63/0.10 63/0.30 80/0.03 80/0.10 80/0.30 100/0.03 100/0.10 100/0.30 mrcm-25/4/003 142781 1/30 mrcm-25/4/01 142783 1/30 mrcm-25/4/03 142785 1/30 mrcm-40/4/003 142787 1/30 mrcm-40/4/01 142789 1/30 mrcm-40/4/03 142791 1/30 mrcm-63/4/003 142793 1/30 mrcm-63/4/01 142795 1/30 mrcm-63/4/03 142797 1/30 mrcm-80/4/003 142799 1/30 mrcm-80/4/01 142801 1/30 mrcm-80/4/03 142803 1/30 mrcm-100/4/003 142805 1/30 mrcm-100/4/01 142807 1/30 mrcm-100/4/03 142809 1/30 Residual Current Devices mrcm Conditionally surge current-proof 250 A, sensitive to residual pulsating DC, type A I n /I Δn (A) Type Designation Article No. Units per package wa_sg03810 2-pole 16/0.01 16/0.03 25/0.03 25/0.1 25/0.3 40/0.03 40/0.10 40/0.30 63/0.03 63/0.10 63/0.30 80/0.03 80/0.10 80/0.30 100/0.03 100/0.10 100/0.30 mrcm-16/2/001-a 158060 1/60 mrcm-16/2/003-a 142749 1/60 mrcm-25/2/003-a 142751 1/60 mrcm-25/2/01-a 142753 1/60 mrcm-25/2/03-a 142755 1/60 mrcm-40/2/003-a 142757 1/60 mrcm-40/2/01-a 142759 1/60 mrcm-40/2/03-a 142761 1/60 mrcm-63/2/003-a 142763 1/60 mrcm-63/2/01-a 142765 1/60 mrcm-63/2/03-a 142767 1/60 mrcm-80/2/003-a 142769 1/60 mrcm-80/2/01-a 142771 1/60 mrcm-80/2/03-a 142773 1/60 mrcm-100/2/003-a 142775 1/60 mrcm-100/2/01-a 142777 1/60 mrcm-100/2/03-a 142779 1/60 3

Protective Devices Part No. 9

Protective Devices 12

Protective Devices Part No. 13

Protective Devices 14

Protective Devices Part No. 17

Sub-distribution solutions MEM series MCB single phase distribution boards MCB three phase distribution boards MCCB Panelboards Switch and protection devices Control and switching devices Metering solutions Smart solutions for electrical distribution in commercial buildings

Sub-distribution solutions MEM series Contents 1 Product overview 5 2 Memshield 3 MCB distribution boards and enclosures 17 3 Switch and protection devices 29 4 Control and switching devices 37 5 Series G MCCB panelboards 43 6 Technical data 67 Indices 98 SUB-DISTRIBUTION SOLUTIONS MEM SERIES PG01415001U November 2010 3

2.1 Memshield 3 MCB distribution boards and enclosures Type A, SPN distribution boards See page 68 for technical data and overall dimensions EAM10 125A SPN, type A distribution boards When more than 16 SP ways are required, see our TPN board ranges, complete with single phase kit options Description Rating Total no. of Eaton list (A) outgoing ways number 4 way SPN, type A distribution board 125 4 EAM4 7 way SPN, type A distribution board 125 7 EAM7 10 way SPN, type A distribution board 125 10 EAM10 13 way SPN, type A distribution board 125 13 EAM13 16 way SPN, type A distribution board 125 16 EAM16 EAMS1251N Incoming devices for SPN, type A distribution boards Incoming devices supplied separate to distribution board Description Rating Poles Sensitivity Eaton list (A) (ma) number Switch-disconnector 125 SPSN EAMS1251N RCCB incoming device for SPN, type A distribution board 100 1P+N 30 EAMS100HE RCCB incoming device for SPN, type A distribution board 100 1P+N 100 EAMS100ME RCCB incoming device for SPN, type A distribution board 100 1P+N 300 EAMS100LE Direct connection kit for SPN, type A distribution board 100 1P+N EAMBT1002 EAMMP65 Metered SPN, type A distribution boards & standard meter packs Type A SPN boards, fitted with multifunction meters, can display; Amps, kw, kwh, kvar and kvarh pulsed output etc. Split load versions utilise a two channel meter, feeding two independent busbars and groups of MCB/RCBOs Split load versions provide independent monitoring of Power and Lighting loads and total load. Aids compliance with Part L2 of the building regulations (England & Wales) Description Rating Total no. of Installed meter, Eaton list (A) outgoing ways characteristics number Meterpack for SPN, type A distribution boards 65 Pulsed output, kwh EAMMP65 9 way SPN, type A distribution board 1) 65 9 Pulsed output, kwh EAM9M 9 way SPN, type A distribution board 1) 65 9 Modbus EAM9MB 12 way SPN, type A distribution board 1) 65 12 Pulsed output, kwh EAM12M 12 way SPN, type A distribution board 1) 65 12 Modbus EAM12MB Split metered SPN, type A distribution board 1), 2) 100 9 + 3 Pulsed output, kwh EAMSL93M Split metered SPN, type A distribution board 1), 2) 100 9 + 3 Modbus EAMSL93MB Split metered SPN, type A distribution board 1), 2) 100 6 + 6 Pulsed output, kwh EAMSL66M Split metered SPN, type A distribution board 1), 2) 100 6 + 6 Modbus EAMSL66MB 1) Includes factory fi tted switch disconnector and single channel meter 2) Includes two channel meter, 65A max load per channel EM3SSK1T2 Surge protection device for SPN, type A distribution boards Description Enclosed surge protection kit for SPN boards type 2 Eaton list number EM3SSK1T2 18 SUB-DISTRIBUTION SOLUTIONS MEM SERIES PG01415001U November 2010

Memshield 3 MCB distribution boards and enclosures Type B, TPN distribution boards 2.2 See page 68 for technical data and overall dimensions EBM81 125A/250A TPN, type B distribution boards Description Rating Total no. of Eaton list (A) outgoing ways number 4 way TPN, type B distribution board 125 4 EBM41 6 way TPN, type B distribution board 125 6 EBM61 8 way TPN, type B distribution board 125 8 EBM81 12 way TPN, type B distribution board 125 12 EBM121 16 way TPN, type B distribution board 125 16 EBM161 12 way TPN, type B distribution board 125/250 1) 12 EBM122 18 way TPN, type B distribution board 125/250 1) 18 EBM182 24 way TPN, type B distribution board 125/250 1) 24 EBM242 1) 250A option if used with cable extension box or with cable trunking. See 250A incomer options below EBM121D 125A SPSN, type B distribution board with SPSN main switch disconnector fitted Incoming devices supplied separate to distribution board. Description Rating Total no. of Eaton list (A) outgoing ways number 12 way SPSN type B distribution board 125 12 EBM121D EBMS1253 125A incomer options for type B distribution boards Incoming devices supplied separate to distribution board. Description Rating Pole Eaton list (A) configuration number Switch disconnector 125 TP EBMS1253 Switch disconnector kit (including single phasing link) 125 SPSN EBMS1251N Switch disconnector 125 TPSN EBMS1253N Direct connection (lugs connector) 125/250 TP EBMBT2503 30mA RCCB 1) 100 TPSN EBMR30 100mA RCCB 1) 100 TPSN EBMR100 300mA RCCB 1) 100 TPSN EBMR300 300mA RCCB with time delay 100 TPSN EBMR300T Switch disconnector feeding 125A TP AC1 contactor, housed in extension box 125 TP EBMCC1253 125A MCCB (50kA adjustable NZM), housed in extension box 125 TP EBMMB1253 1) Includes 50mm 2 terminal adapter EBM62H 250A TPN, type B high load distribution board These boards include 2 TPN outgoing ways for 27mm MCB (upto 125A) Adequate integral cabling space means that no extension box is required. Description Rating Total no. of 18mm Total no. of 27mm Total no. of Eaton list (A) TP outgoing ways TP outgoing ways outgoing ways number (63A max) (125A max) 2 way TPN, type B distribution board 250 0 2 2 EBM22H 6 way TPN, type B distribution board 250 4 2 6 EBM62H 8 way TPN, type B distribution board 250 6 2 8 EBM82H 12 way TPN, type B distribution board 250 10 2 12 EBM122H 18 way TPN, type B distribution board 250 16 2 18 EBM182H 24 way TPN, type B distribution board 250 22 2 24 EBM242H SUB-DISTRIBUTION SOLUTIONS MEM SERIES PG01415001U November 2010 21