R&S BBL200 Broadband Amplifier Specifications

Similar documents
R&S ZN-Z154 Calibration Unit Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S ZN-Z85 Switch Matrix Specifications

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S HF907DC SHF Downconverter Specifications

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S SMBV-Z1 Reference Frequency Converter Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S ZN-ZTW Torque Wrench Specifications

R&S ZVA110 Vector Network Analyzer Specifications

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

R&S AVG050 DVB Satellite Receiver Specifications

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

R&S FSW-K144 5G NR Measurement Application Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S GU221 Filter Control Unit Specifications

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

R&S FSV-K40 Phase Noise Measurement Application Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S DST200 RF Diagnostic Chamber Specifications

R&S FPC1000 Spectrum Analyzer Specifications

R&S RT-Zxx Standard Probes Specifications

R&S ZND Vector Network Analyzer Specifications

R&S EDS300 DME/Pulse Analyzer Specifications

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

R&S SGU100A SGMA Upconverter Specifications

R&S DDF200M Digital Direction Finder Specifications

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

R&S BBA150 Broadband Amplifier Excellent amplifiers from 9 khz to 6 GHz with high power density

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

R&S BBA130 Broadband Amplifier The amplifier you can tune

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S ZNBT Vector Network Analyzer Specifications

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

R&S RSC Step Attenuator Where precise signal levels count

R&S ELEKTRA EMI Test Software Easy to use software for measuring electromagnetic disturbances

R&S Spectrum Rider FPH Handheld spectrum analyzer

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

R&S FPS-K18 Amplifier Measurements Specifications

R&S SGS100A SGMA RF Source Specifications

R&S FPC-Z10 Teaching Kit Getting Started

Your partner in testing the Internet of Things

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S GX460 Digital Wideband Storage Device Recording and replaying device for I/Q data with up to 40 MHz bandwidth

R&S GX465 Digital Wideband Storage Device Recording and replaying of I/Q data with up to 80 MHz bandwidth

Product Brochure Version R&S BBL200 Broadband Amplifier Liquid-cooled power amplifiers for high field strengths

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

R&S EDST300 TACAN/DME Station Tester Specifications

R&S M3TR R&S VT3050C 50 W VHF/UHF Compact Power Amplifier Specifications

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

EUTRA/LTE Downlink Specifications

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

Product Brochure Version R&S OSP Open Switch and Control Platform Modular solution for RF switch and control tasks

RF amplifier testing from wafer to design-in

R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

EX-IQ-Box Digital Signal Interface Module Specifications

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications

Scope of the art Scope Rider Handheld digital oscilloscope

EUTRA/LTE Measurement Application Specifications

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

Mastering Phase Noise Measurements (Part 3)

R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards

R&S ZNrun Automated Test Software PC-based server platform for automated VNA tests

R&S RT-ZM Modular Probe System

R&S SGMA Product Family Compact fast reliable

R&S NRPM Over-the-Air (OTA) Power Measurement Solution Specifications

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications

R&S PSL3 Industrial Controller The powerful industrial controller

R&S TS-PSM5 High-Power Switching Module Automotive DUT supply and load switching up to 50 A

R&S VSE Vector Signal Explorer Base Software Specifications

R&S TS-PFG Function Generator Module Dual-channel arbitrary waveform generator with isolated outputs

R&S NRP Power Sensor Family Specifications

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

R&S TS-PSM3 High-Power Switching Module Automotive DUT supply and load switching up to 30 A

R&S FPC Spectrum Analyzer Unexpected performance in entry class

Pre-5G-NR Signal Generation and Analysis Application Note

Test Device Containment Module (TCM) Optimal conditions for reliable results

R&S CA210 Signal Analysis Software Offline analysis of recorded signals and wideband signal scenarios

Oscilloscopes for debugging automotive Ethernet networks

WLAN IEEE802.11a/b/g/j/p/n/ac/ax Measurement Application Specifications

R&S EFL110/EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks

R&S XLx8000 UHF/VHF Transposers Efficient solutions for analog and digital broadcasting standards

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Transcription:

BBL200_dat-sw_en_3606-9456-22-umschlag.indd 1 Data Sheet 03.00 Test & Measurement R&S BBL200 Broadband Amplifier Specifications 02.07.2015 14:04:44

CONTENTS Definitions... 3 Frequency band from 9 khz to 225 MHz... 4 Power class 3000 W... 4 Frequency response at 1 db compression (or better)... 4 RF specifications... 4 Mechanical specifications... 5 Electrical specifications... 5 Cooling specifications... 6 Power class 5000 W... 7 Frequency response at 1 db compression (or better)... 7 RF specifications... 7 Mechanical specifications... 8 Electrical specifications... 8 Cooling specifications... 9 Power class 10000 W... 10 Frequency response at 1 db compression (or better)... 10 RF specifications... 10 Mechanical specifications... 11 Electrical specifications... 11 Cooling specifications... 12 General data... 13 Modulation specifications... 13 Control specifications... 13 Environmental specifications... 13 Protection... 14 Ordering information... 15 R&S BBL200 single-band power amplifiers... 15 Frequency band from 9 khz to 225 MHz... 15 Options... 15 Service... 15 Rohde & Schwarz equipment is designed for reliable operation up to an altitude of 2000 m above sea level, and for transport up to an altitude of 4600 m above sea level. All specified parameters are valid for an ambient temperature of +25 C, input impedance of and output impedance of. Data without tolerance limits is not binding. RoHS Europe, Directive 2011/65/EU: equipment category 9, fulfilled without any exceptions. WEEE Europe, Directive 2002/96/EC: No disposing with unsorted municipal waste; no return with collection of waste electrical and electronic equipment from private households. Separate collection necessary. Ask Rohde & Schwarz representatives about recovery. 2 Rohde & Schwarz R&S BBL200 Broadband Amplifier

Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value. Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Uncertainties Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear. Device settings and GUI parameters are indicated as follows: parameter: value. Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. Rohde & Schwarz R&S BBL200 Broadband Amplifier 3

Frequency band from 9 khz to 225 MHz Power class 3000 W Frequency response at 1 db compression 4000 3500 3000 Power in W 2500 2000 1500 1000 500 0 0,001 0,01 0,1 1 10 100 1000 Frequency in MHz RF specifications Main parameters Frequency range 9 khz to 225 MHz instantaneously Nominal output load Nominal output power 3000 W (64.8 dbm) Output power 9 khz to 20 MHz min. 3000 W (64.8 dbm) 20 MHz to 110 MHz min. 3400 W (65.3 dbm) 110 MHz to 225 MHz min. 2800 W (64.5 dbm) Power output at 1 db compression 9 khz to 110 MHz min. 3000 W (64.8 dbm) 110 MHz to 225 MHz min. 2800 W (64.5 dbm) Nominal power gain 68.2 db Gain flatness ±3.0 db Gain adjustment range > 15 db Harmonics 9 khz to 110 MHz at 3000 W < 20 dbc 110 MHz to 225 MHz at 2800 W < 20 dbc Third-order intercept point (TOI) test frequencies 100 khz apart min. 70.0 dbm 200 khz to 1 MHz test frequencies 1 MHz apart min. 70.0 dbm 1 MHz to 250 MHz Spurious carrier offset > 100 khz 80 dbc, max. 70 dbc Noise figure at maximum gain 9 khz to 50 MHz < 16.0 db (nom.) 50 MHz to 225 MHz < 9.0 db (nom.) 4 Rohde & Schwarz R&S BBL200 Broadband Amplifier

Input Nominal input impedance Input level for nominal output power 3.4 dbm Input VSWR at max. 2:1 Maximum input level RF +5 dbm DC 0 V Output Nominal output impedance Nominal forward output power at VSWR < 6:1 continuous, without foldback at VSWR > 6:1 continuous, with gradual foldback to approx. 50 % of output power, depending on load impedance Output mismatch protection, VSWR 100 %, without damage RF sample and detected RF sample signals RF sample signal coupling factor sample ports for forward and reflected RF approx. 70 db, see test report for details Detected RF sample signal level sample ports for detected forward and reflected RF (alternatively) 0.1 V to 3.0 V DC Mechanical specifications Amplifier system Dimensions Weight rack setup, W H D, incl. handles, stands and crane lugs 600 mm 1570 mm 1150 mm (23.62 in 61.81 in 45.28 in) approx. 310 kg (683 lb) Heat exchanger Dimensions W H D, incl. handles and stands 1241 mm 558 mm 400 mm (48.86 in 21.97 in 15.75 in) Dry weight approx. 29 kg (64 lb) Connectors Connecting plate at rack top cover, RF input port N female or alternatively connecting plate at rear sample ports for RF or detected RF N female panel, bottom Ethernet RJ-45 interlock WAGO X-COM, 7-pin, female amplifier state WAGO X-COM, 7-pin, female transparent I/O, optional 2 WAGO X-COM, 7-pin, female RF output port rear panel, bottom 1 5/8" EIA female Mains power rear panel, bottom 5 4 mm 2 power supply cable cable diameter at 380 V to 415 V AC 8 mm to 15 mm cable diameter at 208 V to 240 V AC 13 mm to 26 mm Coolant supply rack top cover, rear panel or bottom 2 40 mm cooling hose Electrical specifications Amplifier system Rated operating voltage Rated current at 230 V per phase 20.5 A Rated power RF cw = 3000 W (eff.), VSWR = 1 14.2 kva Maximum electrical fuse protection 3 63 A 380 V to 415 V AC ± 10 %, three-phase with N, 50 Hz to 60 Hz ± 6 % 208 V to 240 V AC ± 10 %, three-phase 50 Hz to 60 Hz ± 6 % Heat exchanger Nominal operating voltage range Current at 230 V < 1.5 A Power consumption < 350 VA 230 V AC ± 10 %, single-phase, 50 Hz to 60 Hz ± 6 % Rohde & Schwarz R&S BBL200 Broadband Amplifier 5

Cooling specifications Liquid cooling Cooling circuit closed cooling system, automated pressure balancing Coolant 39 % v/v Antifrogen N (based on monoethylene glycol, water and anticorrosion additives) Heat exchanger capacity max. 9.5 kw air volume flow 6200 m 3 /h mounting type indoor or outdoor, floor installation Recommended distance between amplifier pipe length max. 2 20 m system and heat exchanger difference in altitude max. 20 m Cooling hose outside diameter 2 40 mm bending radius 280 mm 6 Rohde & Schwarz R&S BBL200 Broadband Amplifier

Power class 5000 W Frequency response at 1 db compression 7000 6000 5000 Power in W 4000 3000 2000 1000 0 0,001 0,01 0,1 1 10 100 1000 Frequency in MHz RF specifications Main parameters Frequency range 9 khz to 225 MHz instantaneously Nominal output load Nominal output power 5000 W (67.0 dbm) Output power 9 khz to 20 MHz min. 5000 W (67.0 dbm) 20 MHz to 110 MHz min. 5500 W (67.4 dbm) 110 MHz to 225 MHz min. 3500 W (65.4 dbm) Power output at 1 db compression 9 khz to 110 MHz min. 5000 W (67.0 dbm) 110 MHz to 225 MHz min. 3500 W (65.4 dbm) Nominal power gain 70.4 db Gain flatness ±3.0 db Gain adjustment range > 15 db Harmonics 9 khz to 110 MHz at 5000 W < 20 dbc 110 MHz to 225 MHz at 3500 W < 20 dbc Third-order intercept point (TOI) test frequencies 100 khz apart min. 72 dbm 200 khz to 1 MHz test frequencies 1 MHz apart min. 72 dbm 1 MHz to 250 MHz Spurious carrier offset > 100 khz 80 dbc, max. 70 dbc Noise figure at maximum gain 9 khz to 50 MHz < 16.0 db (nom.) 50 MHz to 225 MHz < 9.0 db (nom.) Input Nominal input impedance Input level for nominal output power 3.4 dbm Input VSWR at max. 2:1 Maximum input level RF +5 dbm DC 0 V Rohde & Schwarz R&S BBL200 Broadband Amplifier 7

Output Nominal output impedance Nominal forward output power at VSWR < 6:1 continuous, without foldback at VSWR > 6:1 continuous, with gradual foldback to approx. 50 % of output power, depending on load impedance Output mismatch protection, VSWR 100 %, without damage RF sample and detected RF sample signals RF sample signal coupling factor sample ports for forward and reflected RF approx. 70 db, see test report for details Detected RF sample signal level sample ports for detected forward and reflected RF (alternatively) 0.1 V to 3.0 V DC Mechanical specifications Amplifier system Dimensions Weight rack setup, W H D, incl. handles, stands and crane lugs 600 mm 2050 mm 1150 mm (23.62 in 80.71 in 45.28 in) approx. 460 kg (1014 lb) Heat exchanger Dimensions W H D, incl. handles and stands 1125 mm 925 mm 600 mm (44.29 in 36.42 in 23.62 in) Dry weight 56 kg (123 lb) Connectors Connecting plate at rack top cover, RF input port N female or alternatively connecting plate at rear sample ports for RF or detected RF N female panel, bottom Ethernet RJ-45 interlock WAGO X-COM, 7-pin, female amplifier state WAGO X-COM, 7-pin, female transparent I/O, optional 2 WAGO X-COM, 7-pin, female RF output port rear panel, bottom 1 5/8" EIA female Mains power rear panel, bottom 5 10 mm 2 power cable supply cable diameter at 380 V to 415 V AC 13 mm to 26 mm cable diameter at 208 V to 240 V AC 18 mm to 32 mm Coolant supply rack top cover, rear panel or bottom 2 40 mm cooling hose Electrical specifications Amplifier system Rated operating voltage Rated current at 230 V per phase 35.0 A Rated power RF cw = 5000 W (eff), VSWR = 1 24.0 kva Recommended electrical fuse protection 3 63 A 380 V to 415 V AC ± 10 % three-phase with N, 50 Hz to 60 Hz ± 6 % 208 V to 240 V AC ± 10 % three-phase 50 Hz to 60 Hz ± 6 % Heat exchanger Nominal operating voltage range Current at 230 V < 3.5 A Power consumption < 810 VA 230 V AC ± 10 %, single-phase, 50 Hz to 60 Hz ± 6 % 8 Rohde & Schwarz R&S BBL200 Broadband Amplifier

Cooling specifications Liquid cooling Cooling circuit closed cooling system, automated pressure balancing Coolant 39 % v/v Antifrogen N (based on monoethylene glycol, water and anticorrosion additives) Heat exchanger capacity max. 15.7 kw air volume flow 5145 m³/h mounting type indoor or outdoor, floor installation Recommended distance between amplifier pipe length max. 2 20 m system and heat exchanger difference in altitude max. 20 m Cooling hose outside diameter 2 40 mm bending radius 280 mm Rohde & Schwarz R&S BBL200 Broadband Amplifier 9

Power class 10000 W Frequency response at 1 db compression 14000 12000 10000 Power in W 8000 6000 4000 2000 0 0,001 0,01 0,1 1 10 100 1000 Frequency in MHz RF specifications Main parameters Frequency range 9 khz to 225 MHz instantaneously Nominal output load Nominal output power 10000 W (70.0 dbm) Output power 9 khz to 110 MHz min. 10000 W (70.0 dbm) 110 MHz to 225 MHz min. 8000 W (69.0 dbm) Power output at 1 db compression 9 khz to 110 MHz min. 10000 W (70.0 dbm) 110 MHz to 225 MHz min. 7000 W (68.5 dbm) Nominal power gain 73.4 db Gain flatness ±3.0 db Gain adjustment range > 15 db Harmonics 9 khz to 110 MHz at 10000 W < 20 dbc 110 MHz to 225 MHz at 8000 W < 20 dbc Third-order intercept point (TOI) test frequencies 100 khz apart min. 75.0 dbm 200 khz to 1 MHz test frequencies 1 MHz apart min. 75.0 dbm 1 MHz to 250 MHz Spurious carrier offset > 100 khz 80 dbc, max. 70 dbc Noise figure at maximum gain 9 khz to 50 MHz < 16.0 db (nom.) 50 MHz to 225 MHz < 9.0 db (nom.) Input Nominal input impedance Input level for nominal output power 3.4 dbm Input VSWR at max. 2:1 Maximum input level RF +5 dbm DC 0 V 10 Rohde & Schwarz R&S BBL200 Broadband Amplifier

Output Nominal output impedance Nominal forward output power at VSWR < 6:1 continuous, without foldback at VSWR > 6:1 continuous, with gradual foldback to approx. 50 % of output power, depending on load impedance Output mismatch protection, VSWR 100 %, without damage RF sample and detected RF sample signals RF sample signal coupling factor sample ports for forward and reflected RF approx. 70 db, see test report for details Detected RF sample signal level sample ports for detected forward and reflected RF(alternatively) 0.1 V to 3.0 V DC Mechanical specifications Amplifier system Dimensions Weight rack setup, W H D, incl. handles, stands and crane lugs 1200 mm 2050 mm 1150 mm (47.24 in 80.71 in 45.28 in) approx.870 kg (1915 lb) Heat exchanger Dimensions W H D, incl. handles and stands 2400 mm 1150 mm 600 mm (9445.88 in 452.76 in 236.22 in) Dry weight approx. 238 kg (525 lb) Connectors Connecting plate at rack top cover, RF input port N female or alternatively connecting plate at rear sample ports for RF or detected RF N female panel, bottom Ethernet RJ-45 interlock WAGO X-COM, 7-pin, female amplifier state WAGO X-COM, 7-pin, female transparent I/O, optional 2 WAGO X-COM, 7-pin, female RF output port rear panel, bottom 1 5/8" EIA female Mains power rear panel, bottom 5 35 mm 2 power supply cable cable diameter 18-32 mm Coolant supply rack top cover, rear panel or bottom 2 51 mm cooling hose Electrical specifications Amplifier system Rated operating voltage Rated current at 230 V per phase 72 A Rated power RF cw = 10000 W (eff.), VSWR = 1 50 kva Recommended electrical fuse protection 3 80 A 380 V to 415 V AC ± 10 %, three-phase with N, 50 Hz to 60 Hz ± 6 % 208 V to 240 V AC ± 10 %, three-phase 50 Hz to 60 Hz ± 6 % Heat exchanger Nominal operating voltage range Current at 230 V < 13 A Power consumption < 3000 VA 230 V AC ± 10 %, single-phase, 50 Hz to 60 Hz ± 6 % Rohde & Schwarz R&S BBL200 Broadband Amplifier 11

Cooling specifications Liquid cooling Cooling circuit closed cooling system, automated pressure balancing Coolant 39 % v/v Antifrogen N (based on monoethylene glycol, water and anticorrosion additives) Heat exchanger capacity max. 41 kw air volume flow 20100 m 3 /h mounting type indoor or outdoor, floor installation Recommended distance between amplifier pipe length max. 2 20 m system and heat exchanger difference in altitude max. 20 m Cooling hose outside diameter 2 51 mm bending radius 280 mm 12 Rohde & Schwarz R&S BBL200 Broadband Amplifier

General data Modulation specifications Modulation capability Control specifications Remote control Ethernet AM, FM, φm or PM RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex Local HM Local display 200 48 pixel, monochrome Manual controls resting pushbutton mains switch operation pushbuttons system standby/on RF standby/operate local/remote menu pushbuttons arrow up, down, left, right ok back LED status information system standby/on RF standby/operate mute ready interlock error local/remote Web GUI Remote web GUI via Ethernet RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex Environmental specifications Temperature loading operating temperature range 0 C to +40 C storage temperature range 20 C to +70 C Damp heat max. +40 C at 95 % rel. humidity, without condensation Altitude operating altitude up to 2000 m storage altitude up to 4600 m Calibration interval no calibration needed Electromagnetic compatibility immunity in line with EN 61326-1, public and industrial areas electromagnetic fields 10 V/m, in line with IEC 61000-4-3 surge test: line to ground 2 kv, in line with IEC 61000-4-5 surge test: Ethernet to ground 2 kv, in line with IEC 61000-4-5 surge test: line to line 1 kv, in line with IEC 61000-4-5 bursts 2 kv, in line with IEC 61000-4-4 Electromagnetic emissions overall in line with EN 55011 (CISPR 11), industrial area, ISM group 1 or 2 and FCC 047 CFR part 18, nonconsumer equipment conducted emissions in line with EN 55011, class A radiated emissions equipment for use in shielded areas only, normative limits of EN 55011 group 1/2 class A or FCC 047 CFR part 18 exceeded up to 60 db Electromagnetic field strength all-around the enclosure in line with the limits of rec 1999/519/EC, 26. BImSchV, BGV B11 exposure limit 2 (protection of health and safety of workers, consumers and the general public) Electrical safety in line with EN 61010-1:2010, IEC 61010-1:2011 + Corr. 2011 (third ed.) Rohde & Schwarz R&S BBL200 Broadband Amplifier 13

Protection RF Load VSWR unlimited Interlock 1 device interlock, 1 configurable interlock Input protection against bias voltage optional DC block level 50 V DC Power supply Transient voltage compatibility Switching capacity of internal fuses category II, in line with IEC 60364-4-443 < 10 ka Miscellaneous Thermal overload shutdown at thermal overload Liquid cooling Pressure overload Module exchange pressure relief valve, 5 bar self-shutting valves 14 Rohde & Schwarz R&S BBL200 Broadband Amplifier

Ordering information We recommend that you ask your local Rohde & Schwarz expert to find the solution that is optimally suited to your needs. R&S BBL200 single-band power amplifiers Frequency band from 9 khz to 225 MHz Designation Type Configuration No. 3000 W, liquid-cooled, 31 HU rack model R&S BBL200 BBL200-A3000 5000 W, liquid-cooled, 42 HU rack model R&S BBL200 BBL200-A5000 10000 W, liquid-cooled, 2 42 HU rack model R&S BBL200 BBL200-A10000 Accessories supplied: rack power cord, user manual (printed and on CD), test report, indoor heat exchanger, 2 20 m cooling hose and filling pump. Options Designation Type Order No. GPIB Remote Control R&S BBA-B101 5355.8250.05 DC Block Input Protection (N) R&S BBA-B132 5353.9236.03 Sample ports for forward and reflected RF (N), R&S BBL-B140 5356.9937.02 Interface rear bottom for 3000 W and 5000 W model Sample ports for forward and reflected RF (N), R&S BBL-B140 5356.9937.03 Interface rear bottom for 10000 W model, Interface rack top cover for all models Sample ports for detected forward and reflected RF (N) R&S BBL-B141 5356.9908.02 Transparent I/O R&S BBL-B160 5356.9920.02 Rack wheels R&S ZR1-RW01 5354.4309.02 Service Service options Extended Warranty, one year R&S WE1 Please contact your local Extended Warranty, two years R&S WE2 Rohde & Schwarz sales office. Extended Warranty, three years R&S WE3 Extended Warranty, four years R&S WE4 Extended warranty with a term of one to four years (WE1 to WE4) Repairs carried out during the contract term are free of charge 1. Necessary calibration and adjustments carried out during repairs are also covered. Simply contact the forwarding agent we name; your product will be picked up free of charge and returned to you in top condition a couple of days later. For product brochure, see PD 3606.9456.12 and www.rohde-schwarz.com 1 Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included. Rohde & Schwarz R&S BBL200 Broadband Amplifier 15

Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability About Rohde & Schwarz The Rohde & Schwarz electronics group offers innovative solutions in the following business fields: test and measurement, broadcast and media, secure communications, cybersecurity, radiomonitoring and radiolocation. Founded more than 80 years ago, this independent company has an extensive sales and service network and is present in more than 70 countries. The electronics group is among the world market leaders in its established business fields. The company is headquartered in Munich, Germany. It also has regional headquarters in Singapore and Columbia, Maryland, USA, to manage its operations in these regions. Sustainable product design Environmental compatibility and eco-footprint Energy efficiency and low emissions Longevity and optimized total cost of ownership Certified Quality Management ISO 9001 Certified Environmental Management ISO 14001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 82 28 +86 400 650 58 96 customersupport.china@rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD 3606.9456.22 Version 03.00 July 2015 (we) R&S BBL200 Broadband Amplifier Data without tolerance limits is not binding Subject to change 2015 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany 3606.9456.22 03.00 PDP 1 en 3606945622