Moving to FN15vf Project to re-locate the WCARC VHF/UHF Weak Signal Beacons from FN15wg on the VE3XK Tower

Similar documents
DIY. How to install a PL-259 connector. Parts list: Tools list: Worthwhile projects you can build on your own

The Custom Interconnect Leader TM

BTT rev. a Bob s TechTalk #8

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

QRO Coaxial Tee Fitting by WA4NJP, Ray Rector

3M Distribution Box (DDB)

Type "N" Connectors. Type "N" Interface Dimensions

Solderless RF Connectors

REQUIRED TOOLS. Wire cutters Razor blade Soldering iron Pliers 11/16 Wrench for Tube 18mm Wrench for Ring

DXE-UT-808X Coaxial Cable Stripping Tool

Instructions. Cable with Armor F CAUTION. October Rev A

SMA - 50 Ohm Connectors

E4200 Antenna Installation Instructions: 1. Soldering required (here is the list of tools you will need)

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

ULTIMATE SNAP-N-SEAL

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

Coaxial Cable Termination

A CENTIMETER FM YAGI ANTENNA MHz

Assembly Instructions

Medium Box for Cable Termination

SPECIAL SPECIFICATION 2344 TMC Support Equipment

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Coaxial Cable Feedline Choke Kit - 50 Ω

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Industrial Loadbreak Elbow

Snail Fence InteleCell Deployment Guide

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

SECTION 7 -- CROSS-CONNECT SYSTEMS

Multi-Media Installation Guide

MUK REAR PANEL ASSEMBLY ASSEMBLY INSTRUCTIONS

SMA One Piece Semi-Rigid Connectors

RG-59/RG-6/RG-11 LSZH SERIES MAIN FEATURES

DL-AR2 Technical Specifications Universal HDMI Adapter Ring Rev

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Table 4-1: Rating Levels

Serial Digital BNC Connectors

LEGEND POWER SYSTEMS

LCC (Little Coaxial Connector) Installation Instructions)

Serial Digital BNC Connectors

8D with High Frequency Coaxial Contact

SnapStak Stackable Snap-In Cable Hanger Electrical and Mechanical Testing Performance

Non Magnetic Connectors

SCIR. Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight SCIR

MCX Miniature Coaxial Connectors

HAPPY HOLIDAYS PRESIDENTS NEXT MEETING SUNDAY DECEMBER 9 TH. CORNER.DECEMBER 2012 THE OFFICIAL NEWSPAPER OF THE YONKERS AMATEUR RADIO CLUB

M2 Antenna Systems, Inc. Model No: 23CM35

ASSEMBLY AND INSTALLATION 3 ELEMENT 6 METER BEAM

Digital Modulator Instructions

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

Ultra-Grip Crimp Connector Hand Tool Kit for Coaxial Cable and Powerpole Connectors

3M Cold Shrink Splice Kit QS-III 5515A

Cold Shrink Straight Joint

SUHNER QMA SUBMINIATURE CONNECTORS

ConnectAnywhere Prep Kit OEM INSTALLATION MANUAL

Ultra-Grip 2 Crimp Connector Hand Tool Kit for Coaxial Cable Connectors, Powerpole Connectors, Insulated and Non-Insulated Crimp Terminals

Stainless Steel SMA Connectors Product Catalog

White Paper. Discone Antenna Design

3 SLiC Aerial Closure with Rubber End Seal

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH

Part Number (used with PRO-CRIMPER Tool Frame ) for 50 Ohm BNC Dual Crimp MIL Type Connectors

Amphenol RF Connectors

Satellite Dish Installation Manual (Ver. 2) 1

3M Cold Shrink Splice Kit QS-III 5514A

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

BNC 75 Ohm RF-Connectors


SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.


3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Build your own: Track Display

Your Network Has Evolved. So Has Our Cable.

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Chapter 4. Dish Antenna Installation. Installing a DISH 500 Antenna. Finding the Satellites

HEXXAGONAL BEAM Mark 2

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

QMA and QN connectors, patented products, become some real standard for the RF Telecommunications industry.

HOW TO USE THIS MANUAL

OCT 15 Rev B

Installation Overview

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

MPI Cable Selection Guide

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

VITALink Taped Splice Straight Through Crimp

If you have any problems please contact our office at Thank You! And Enjoy! Like us on Facebook /AllenLeighSC

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE Test Method for Cable Weld Integrity

Ultra-Grip 2 Crimp Connector Hand Tool Kit for Crimp Coaxial Cable Connectors, Powerpole Connectors, Insulated and Non-Insulated Crimp Terminals

Reverse polarity connectors

Transcription:

Moving to FN15vf Project to re-locate the WCARC VHF/UHF Weak Signal Beacons from FN15wg on the VE3XK Tower to FN15vf north of Almonte on a Christie-Walther tower site

The FN15wg Setup

Moving to FN15vf Step 1 Prepare new 50 ft Heliax Feedlines using the 3/8 Andrews LDF2-50 Heliax donated by WCARC Treasurer Ken Asmus - VA3KA

PL-259 to Heliax LDF2-50 3/8 nominal size 50 MHz - 0.73 db loss /100 ft 150 MHz - 1.286 db loss / 100 ft (RG-8X - 4.5 db/100 ft) 200 MHz - 1.494 db loss /100 ft 450 MHz - 2.29 db loss / 100 ft (RG-8X - 8.1 db/100 ft) 1250 MHz - 3.98 db loss / 100 ft LMR-400 losses/100 ft: 150 MHz - 1.5dB, 450 MHz - 2.7 db

PL-259 to Heliax LDF2-50 N-Male N- Female Typical 1/2 Heliax connectors thread onto outer conductor. New - $40+, used - $20 - $30. Less at fleamarkets for Type N. Standard PL-259 connectors can be adapted to fit, as follows.

PL-259 to Heliax LDF2-50 Not shown - Coupling Ring (threads over plug assembly shown) PL-259 Tubing Inside Diameter - 9.5 mm LDF2-50 Outer Conductor Outside Diameter - 9.652 mm PL-259 Centre Pin Inside Diameter - 2.2 mm LDF2-50 Inner Conductor Outside Diameter - 3.048 mm

PL-259 to Heliax LDF2-50 The First Problem Enlarge the PL-259 Tubing Inner Diameter from 9.5 mm to accommodate the LDF2-50 outer conductor diameter of 9.652 mm Next standard drill size above 3/8 is 25/64 (9.92 mm) Solution Carefully drill out the PL-259 tubing taking care not to remove too much metal from the area around the solder holes. Drill a bit past the solder holes to accommodate the LDF2-50 outer conductor when inserted.

PL-259 to Heliax LDF2-50

PL-259 to Heliax LDF2-50 Heliax Stripping Instructions Use tubing cutter or Dremel saw tool to cut through the jacket, corrugated copper outer conductor, and foam dielectric insulation using the above dimension drawing Core Grinding Using Dremel sanding drum, grind core down from 3.048 mm diameter to less than 2.2 mm. Use a PL-259 to check the fit along the length of the exposed core.

PL-259 to Heliax LDF2-50 Stripping the heliax using a Dremel tool saw

PL-259 to Heliax LDF2-50 Grinding down heliax core using Dremel sanding drum tool

PL-259 to Heliax LDF2-50 Preparation for Soldering Position the modified PL-259 over the modified LDF2-50 The corrugated outer conductor should show through the solder holes and the modified LDF2-50 core should project out to the tip of the PL-259 centre pin Make final adjustments to the stripping and drilling dimensions if necessary using the Dremel tool. It should not be necessary to grind down the thin heliax outer shield. Ensure the PL-259 threaded coupling ring is on the cable and properly oriented before starting to solder.

PL-259 to Heliax LDF2-50 Fine tuning of PL-259 inner diameter using reamer tool

PL-259 to Heliax LDF2-50 Soldering Conventional solder works, but Solder-It silver bearing solder paste provides lower melting point (430F), 5X strength and extremely high electrical conductivity. Use a fine point butane torch for best results and to avoid dielectric damage due to excess heat. Apply solder paste to centre pin and through solder holes. Apply the butane flame to the work not the solder. When the surrounding area gets up to 450F the solder paste will quickly flow. Remove heat immediately. Note: Silver solder is not shiny when cool after melting.

PL-259 to Heliax LDF2-50 SOLDER-IT silver solder paste melts at only 450F

PL-259 to Heliax LDF2-50 The Finishing Touches After soldering is complete, slide down and screw on the threaded coupling ring Securely seal the cable to the connector body using X-TREME TAPE self-bonding silicone rubber tape. Add cable colour-coding tape if needed for your application. Sources X-TREME TAPE: $9 - Benson s Auto Parts - Bell s Cors SOLDER-IT: www.solderit.com

Moving to FN15vf The Christie-Walther pager tower north of Almonte

Moving to FN15vf On site, we had to connect the new heliax feedlines

Moving to FN15vf and slip the beacon mast into our heavy duty 2 mast, before lifting the assembly over the fence and standing it up

Moving to FN15vf Lower portion of tower showing our mast attached to fence

Moving to FN15vf VE3WCC Beacon enclosure hung on the tower with LDF2-50 dressed around mid-line of fence to mast on the south side

Moving to FN15vf Heliax formed into loop for ease of site maintenance access

Moving to FN15vf VE3WCC/B in operation next to Christie - Walther Pager Tower. Feedpoint elevation 485 ft ASL - same as at VE3XK

Moving to FN15vf The re-location team: Barney - VA3BGB, Andy - VE3NVK, Phil - VE3CIQ and Doug - VE3XK (with Tom - VE3ELM on camera)

Moving to FN15vf Additional Work Completed after the Move Installation of station identification EPROM programmed with Grid FN15vf identifier. Rebuild of Keyer Module to obtain 5 MS time constant on the P-Channel MOSFET keyer output. Replacement of UHF feed-through adapters with UHF Female bulkhead connectors, thus eliminating three coaxial adapters per band.

Moving to FN15vf The Results? Within the first day, Ken - VA3KA monitored a DX-spot stating that VE3WCC/b 6M beacon had been heard in Newfoundland. From FN15wg it had been heard in Florida, and 2M beacon heard south of Brantford near Lake Erie! Various WCARC members have reported hearing the other beacons - in some cases better than at the temporary initial location on the VE3XK tower. Better feedlines? Better location? Both? Ken - VA3KA reports that key clicks are gone now. Keep listening. Spread the word. We need more people listening to the beacons and more signal strength reports.