Master Clock Controller. User Guide. pyramidtimesystems.com

Similar documents
Master Clock Controller. User Guide. pyramidtimesystems.com

Master Clock Controller. User Guide. pyramidtimesystems.com

Installation Instructions

TIMETRAX SYNC RF WIRELESS DIGITAL CLOCK Installation Instructions

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

Master Time Clock MTC Users Manual

Indoor/Outdoor Security System with Quad Monitor User s Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

SBL /SBLG Series Wireless Clock

Valcom Wired Digital Clock

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

7 Day Digital Programmer 3 Channel Surface Mount

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

FD171CV-C-4. Installation and Operation Manual. 17 HDSDI Special Mission Quad Monitor. Revision Date: 01/11/2017 Page 1 of 14.

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

INSTALLATION INSTRUCTIONS FOR

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

FD70CV-M-C-6. Installation and Operation Manual. 7 Widescreen LCD /Standard Arm. Revision Date: 05/05/2017 Page 1 of 13. Rev: B

SSPT724A Timer Quick Start Guide

In-Wall Control Mount for ipod Touch

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

By CHANNEL VISION. Flush Mount Amplifier A0350

I1000M Rough-In Instructions

CC2000 SERIES SYSTEM CLOCKS / DISPLAYS

User Guide. Auto Totaling Time Clock. pyramidtimesystems.com 3/07/12. M. Scott. M. Scott PAYABLE TIME DATE AND TIME PAYABLE TIME DATE AND TIME

Model UH-2C-3S 3-port HDMI UTP Extender

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

FD104CV. Installation and Operation Manual 10.4 LCD. Revision Date: 08/01/2017 Page 1 of 14. Rev: G. Document Number: MAN FD104CV

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Model /29S RF Splitter

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Installation and Operation Manual. YMP Series Signal Programmer

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

ALPHA Personal Priority Display User Manual

Overview: Specifications: Installation Instructions:

User s Manual. 4X1 HDMI Switcher Part #: DL-HDS41

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

INSTALLATION MANUAL. Model: HDD. ATSC/QAM Digital to Analog Demodulator

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

FD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or Document Number: Rev:

Extender for HDMI over one CAT5

LIGHT COPILOT II. elationlighting.com Internet:

FD104CV-C-L/R-1. Installation and Operation Manual LCD Monitor Left/Right Arm Mount. Revision Date: 07/28/2017 Page 1 of 13.

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

Doorphone Video Intercom

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

TAC1 Telephone Entry System

Owner s Manual. HDMI over Cat5/Cat6 Active Extender with Built-in 4K Upscaler. Models: B126-1A0-SC4K and B126-1A1-SC4K

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Instruction Manual Model # Block Upconverter

ICS Digital Menu. Installation Guide Version 1.1

Instruction Manual Model BlockUpconverter

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

Access Control Keypad for MK-DV, JB-DV

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

User Instructions. 16 SCB Sync Station.

VGA Extender LR EXT-VGA-141LR. User s Manual

FD70CV-M-C-9. Installation and Operation Manual. 7 NVG Compatible LCD. Revision Date: 06/16/2017 Page 1 of 12. Rev: A

TALKBACK INTERCOM SYSTEM V-2927 CLOCK CONTROL CARD FOR THE V-2924A

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

VS-162 / VS-164. User Manual

Electronic 1-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

Kramer Electronics, Ltd. USER MANUAL. Models: OC-1N, Video Isolator OC-2, Dual Channel Video Isolator OC-4, Quad Channel Video Isolator

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

AE SERIES GPS MASTER CLOCK SYSTEMS

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Owner s Guide. Model L32C205 TABLE OF CONTENTS

Extender w/ RS-232 and 2-way IR

In-Line or 75 Ohm In-Line

VITEK VTM-TLM191 VTM-TLM240

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

Personal Information Page

OWNER'S MANUAL SIGNAL COMMANDER

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Extender for HDMI. gefentoolbox.com GTB-HDBT-POL GTB-HDBT-POL-BLK. User Manual

SC-C1M SiriusConnect TM Vehicle Tuner

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Kramer Electronics, Ltd. USER MANUAL. Model: VM-3A. Audio Distributor

Composite Video Extender

MAN FDAIP-CVH VER HDSDI

Troubleshooting Guide 9630 Series

FDVGA-SDI. Installation and Operation Manual. VGA to HDSDI Converter. Revision Date: 09/10/2014 Page 1 of 9. Rev: B. Document Number: MAN FDVGA-SDI

Scale Track System. 21 Century y Signal System 2-Rail Manual

TALKBACK INTERCOM SYSTEM V-2927 CLOCK CONTROL CARD FOR THE V-2924A

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

VGA Extender SRN. EXT-VGA-141SRN. User Manual

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

User Manual. VGA and Audio Cat-X AV Extender V1.0 AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T AVE-304TR AVE-308TR

TALKBACK INTERCOM SYSTEM VC-2927 CLOCK CONTROL CARD FOR THE VC-24

Kramer Electronics, Ltd. USER MANUAL. Model: VP-100. VGA/XGA to RGBHV Converter

Transcription:

Master Clock Controller User Guide pyramidtimesystems.com

TABLE OF CONTENTS TABLE OF CONTENTS... PRODUCT OVERVIEW... FEATURES... 3 CONTENTS... 4 WALL MOUNTING... 5 INSTALLATION... 6 PROGRAMMING... 7-8 CLOCK CONNECTION...9- BELL CONNECTION... 3-4 BELL SCHEDULE... 5 SPECIFICATIONS... 6-7 ACCESSORIES... 8 WARRANTY & TECHNICAL SUPPORT... 9 TABLE OF CONTENTS 888.479.764

OVERVIEW Thank you for choosing a TimeTrax Sync 7000/7000BDL0 Master Clock System. The TimeTrax Sync 7000/7000BDL0 synchronizes up to 00 TimeTrax Sync Analog Clocks (part #500) and/or Digital Clocks (part# DIG4B, DIG6B) The system can provide power to eight TimeTrax Sync Analog Clocks (part #500) using RJ45 connector. Digital Clocks need to have their own 00-40V AC 50/60Hz power supplied. The TimeTrax Sync 7000 integrates with 4V DC bells or horns and is able to operate a bell/horn schedule up to 300 events per 4 hours. The TimeTrax Sync 7000BDL0 includes a Relay SPDT contact for bells and horns. The contact rate is 0amps @ 5V AC or 7A @30V DC. Please refer to page 7 for a complete list of bell and horns. Analog or Digital Clock 7000 master control (BCD updates up to 00 clocks*) DC Bells/Horns or AC Relay Control *Powers up to 8 analog clocks using RJ45 cable. All other clocks must be supplied power. PRODUCT OVERVIEW

7000/7000BDL0 MASTER CLOCK CONTROLLER : FEATURES 7000 7000BDL0 Synchronization Capacity 00 TimeTrax Sync Analog and/or Digital Clocks 00 TimeTrax Sync Analog and/or Digital Clocks Synchronization Distance Up to 300 feet Up to 300 feet Analog Clock Power Up to 8 Analog Clocks (part #500) using RJ45 Up to 8 Analog Clocks (part #500) using RJ45 Bell/Horn Interface 4V DC Bells and Horns 0V AC Bells and Horns Bell Scheduling Up to 300 Events Up to 300 Events Bell & Horn Power Up to 35 bells (part #436 & 439) or 800 milliamps (ma) per event Up to 0 horns (part #436) or 800 milliamps (ma) per event Contact SPDT 0amps total @ 5V AC, 7A @ 50V AC or 7A @ 30V DC Bells #4397R & #4398G Horns #4363 Display Date & Time (AM/PM or Military) Date & Time (AM/PM or Military) Automatic Time Adjustment Short months, Leap Year & Daylight Saving Time Short months, Leap Year & Daylight Saving Time Tamper-Proof Security Lock Yes Yes Warranty -Year manufacturer's limited warranty -Year manufacturer s limited warranty 3 FEATURES 888.479.764

CONTENTS Master Clock Controller User Guide TimeTrax Sync 7000 Master Clock Controller Relay (7000BDL0 ONLY) Power Adapter pyramidtimesystems.com 7000/7000BDL0 User Guide RJ45 Splitter Cable CH75 CH75 RJ45 50 Cable Security Keys () Mounting Screws (4) Wall Anchors (4) CONTENTS 4

WALL MOUNTING Use key to unlock and open front cover. 3 Select a location for mounting. Power outlet should be within 5 feet of mounting location. With door, open, hold the case in desired location and mark holes for drilling. Drill holes for mounting. 4 5 Install screws in wall, leaving approximately 3/6 inch of screws exposed. For sheet rock walls, use plastic anchors. Hang TimeTrax Sync 7000 on wall, aligning keyholes on the rear with screw heads. Press downward on case until it lowers onto screws. 5 WALL MOUNTING 888.479.764

INSTALLATION/7000 Route the power supply through cable channel located on right side or bottom of the 7000 case. Connect power supply into power port labeled POWER. Plug power supply into standard electrical wall outlet. SELECT SET-UP INSTRUCTIONS To change or set feature, 3 After displayed feature is press SELECT until desired feature is displayed. Use or to change feature. DATA 4 VDC + - changed, press SELECT to change other feature & return to main display. POWER pyramidtimesystem.com 430A INSTALLATION 6

PROGRAMMING SELECT SET-UP INSTRUCTIONS To change or set feature, 3 After displayed feature is press SELECT until desired changed, press SELECT to feature is displayed. 4 VDC change other feature & + - Use or to change return to main display. feature. DATA POWER pyramidtimesystem.com 430A 3 4 Locate programming buttons labeled SELECT, (s) (UP) & (t) (DOWN). Press SELECT until desired feature is displayed (see chart on next page). Press (s) (UP) or (t) (DOWN) to scroll through feature options. Press SELECT to save option setting and move onto next feature. 7 PROGRAMMING 888.479.764

7000 MASTER CLOCK CONTROLLER : PROGRAMMING Feature (SELECT) Display Default Setting Options (Scroll st) Schedule Bells NO NO: No event(s) scheduled. YES: Schedule event(s) SET EVENT #-300 See instruction on p.5. Date Format USA Use the UP or DOWN key to select USA or EURO (European) display format for time. Set Year 00 Use the UP or DOWN key to set the current year. Set Month JAN Use the UP or DOWN key to set the current month. Set Day Use the UP or DOWN key to set the current day of month. Set Daylight Saving Time (DST) Rule USA USA: USA DST: Begins nd SUN of MAR, Ends st SUN of NOV EURO: European DST: Begins Last SUN of MAR, Ends Last Sun of OCT OTHER: Set a custom DST Rule Choose from LINE or CRYSTAL time base. OFF: No adjustment for DST. Set Format AM/PM AM/PM: Hour MIL: Military, 4 Hour Set Hour AM Use the UP or DOWN key to set the current hour of day. Set Minutes 00 Use the UP or DOWN key to set the current minute. PROGRAMMING 8

CLOCK CONNECTION 3 Using RJ45 BCD Cable, connect one end of the cable to the 7000 port labeled DATA and route cable through cable channel located on the right side or bottom of 7000 case. Connect the other end of the RJ45 cable to port located on back of Analog or Digital clock. Mount and install wall clocks according to instructions included with clock. SELECT SET-UP INSTRUCTIONS To change or set feature, 3 After displayed feature is press SELECT until desired changed, press SELECT to feature is displayed. 4 VDC change other feature & + - Use or to change return to main display. feature. DATA POWER pyramidtimesystem.com 430A 9 CLOCK CONNECTION 888.479.764

CLOCK CONNECTION Use RJ45 Splitter Cable (part # 470) to add more clocks. Up to 00 clocks may be added to the system, however clocks should be located within 300 feet of 7000 unit to receive the synchronization time data (BCD signal). SELECT SET-UP INSTRUCTIONS To change or set feature, 3 After displayed feature is press SELECT until desired changed, press SELECT to feature is displayed. 4 VDC change other feature & + - Use or to change return to main display. feature. DATA POWER pyramidtimesystem.com 430A CLOCK CONNECTION 0

CLOCK CONNECTION (BCD) SELECT SET-UP INSTRUCTIONS To change or set feature, After displayed feature is press SELECT until desired changed, press SELECT to feature is displayed. 4 VDC change other feature & + - Use or to change return to main display. feature. DATA POWER pyramidtimesystem.com 3 430A DIG-4B DIG-4B DIG-4B DIG-4B DIG-4B 0V AC 60Hz 300 470 Y-Splitter CLOCK CONNECTION 888.479.764

CLOCK CONNECTION (BCD & POWER) SELECT SET-UP INSTRUCTIONS To change or set feature, After displayed feature is press SELECT until desired changed, press SELECT to feature is displayed. 4 VDC change other feature & + - Use or to change return to main display. feature. DATA POWER pyramidtimesystem.com 3 430A 470 Y-Splitter 7000 Master Clock powers up to 8 clocks using RJ45 cable. For more than 8 clocks, use 5300 (up to 8 clocks) or power up clocks individually from 0V AC 60Hz sources using a licensed electrician. 500 500 500 500 500 Black & White 0V AC 60Hz 300 CLOCK CONNECTION

SELECT 3 pyramidtimesystem.com TIMETRAX SYNC 7000/7000BDL0 MASTER CONTROL BELL CONNECTION & SCHEDULE 0V AC BELL CONNECTION WITH 7000BDL0 CAUTION: 0V MUST BE INSTALLED BY A LICENSED ELECTRICIAN. Please refer to diagram. LINE POWER IN 0V AC 7000 COM NO LOAD NEUTRAL NC ON Relay 0V AC BELL SET-UP INSTRUCTIONS To change or set feature, After displayed feature is press SELECT until desired changed, press SELECT to feature is displayed. 4 VDC change other feature & + - Use or to change return to main display. feature. DATA POWER 430A Ø 0 5 30 4 0V AC BELL GROUND 0V AC BELL Line = Black Neutral = Red or White 3 BELL CONNECTION 888.479.764

4V DC BELL CONNECTION The 7000 will provide power to 4V DC bells and/or horns, up to 800 milliamps (ma) per event. Wire 4V DC Bells and/or Horns to the 7000 terminal labeled 4 VDC using 6-0 gauge wire (sold separately) 3 Route the bell wire through the cable channel located on right side or bottom of 7000 case. A total of 35 bells (part #436, 439) or 0 Horns (part #436) can be connected to the circuit. Use the following table to set a bell/ horn schedule. Program up to 300 bell/horn events per 4 hours. SELECT SET-UP INSTRUCTIONS To change or set feature, 3 After displayed feature is press SELECT until desired changed, press SELECT to feature is displayed. 4 VDC change other feature & + - Use or to change return to main display. feature. DATA POWER pyramidtimesystem.com 430A RED (+) BLACK (-) 4V DC BELL 4V DC BELL 4V DC BELL BELL 4V DC BELL BELL BELL CONNECTION 4

SET EVENT MENU : SET EVENT SCHEDULE AN EVENT (e.g. Sound Bells/Horns) Feature (SELECT) Display Default Setting Options (Scroll ) Set Event Schedule Assign the Event a Number (-300) Set the Event s Duration Set the Event s Hour NO Scroll (UP) or (DOWN) to schedule event SET EVENT (e.g.,, 3... 300) OFF AM (AM/PM) 00 (MIL) OFF,.5 SEC, -5 SEC (determines length of time buzzer/bell/horn sounds) EVENT HOUR +/ One Hour HR: AM-PM 4 HR: 00-3 Set the Event s Minute Set the Event s Day 00 EVENT MINUTE +/ One Minute (e.g. 00, 7, 59) ALL Monday thru Friday Event: M-F One day event: SUN, MON, TUE, WED, THU, FRI, SAT All week event, SUN-SAT: ALL 5 BELL SCHEDULE 888.479.764

SPECIFICATIONS 7000 SPECIFICATIONS Part# Time Set Power Output Power BCD Time Updates Operating Temp Display Housing Color Mounting Warranty Dimensions Weight Shipping Weight 7000/7000BDL0 Manual. 4V DC 800mA (bells, horns, relay). 4V DC using RJ45 (powers up to 8 analog clocks, #500, #57N) Power Adaptor 0V AC/8V AC, 000mA Up to 00 clocks, using RJ45-30 F (-34.44 C) to 30 F (54.44 C) LCD, date & time Textured powder coat surface metal Black Wall Mount -Year manufacturer s limited warranty 5.5 W x 7.5 H x.75 D (3.9cm x 8.cm x 4.4cm).8lbs (.8kg) 4.45lbs (.0kg) BELL RELAY SPECIFICATIONS* Contact Rating Color Mounting Dimensions Weight Shipping Weight 0A @ 5V AC, 7A @ 50V AC (SPDT) Putty Wall Mount 3.5 W x 5.5 H x.65 D (7.93cm x 3.33cm x 6.66cm).75lbs (.34gr) lb (.045gr) Included with 7000BDL0. SPECIFICATIONS 6

SPECIFICATIONS 7.5in 5.5in.75in 5.5in SPDT RELAY 5.5in.65in 3.5in 7 SPECIFICATIONS 888.479.764

ACCESSORIES PART # DESCRIPTION DIG-4B 4 x 4-digit Red LED Independent Digital Clock DIG-6B 4 x 6-digit Red LED Independent Digital Clock 4357G 4 x 4-digit Red LED Digital Clock 6357G 4 x 6-digit Red LED Digital Clock 500 3 Analog Clock Hour Face 57N 7 Analog Clock Hour Face 5300* Single Bell Ringer 400 Power Adaptor 0V AC/8V AC 469 RJ45 BCD Cable, 50 434 RJ45 BCD Cable, 00 470 RJ45 Y-Splitter Cable 436 6 4V DC Bell 439 8 4V DC Bell 436 4V DC Horn 4363 0V AC Horn (7000BDL0 ONLY) 4397R 6 0V AC Bell, red (7000BDL0 ONLY) 4398G 8 0V AC Bell, grey (7000BDL0 ONLY) 4449 Bell Wire, 00 Spool ( Conductor 0 AWG 80 C, 300V) 4450 Bell Wire, 50 Spool ( Conductor 8 AWG 80 C, 300V) * Powers up to eight 500 or 57N Analog Clocks using RJ45. ACCESSORIES 8

WARRANTY -YEAR LIMITED WARRANTY Pyramid warranties its Synchronized Clock Systems to the original user against defective material or workmanship for a period of year from date of purchase. The manufacturer s responsibility under this Warranty is limited to repair or replacement of defective part or parts. Pyramid reserves the right to determine whether parts failed because of defective material, workmanship, or other causes. Failure caused by accident, alteration, misuse or improper packaging of returned unit is not covered by this Warranty. Any repair to equipment other than by Pyramid voids the Warranty. Users in territories other than USA, Canada, South America & Australia should contact the Dealer from whom the unit was purchased. The rights under this Warranty are limited to original user and may not be transferred to subsequent users. If Customer Support cannot troubleshoot your problem over the phone, we will replace your unit free of charge if it is within warranty period. Please contact Customer Support at 888.479.764 between the hours of 8am-5pm EST for details. TECHNICAL SUPPORT Should you need to speak live to one of our representatives, please call toll-free (US/Canada) at 888.479.764 during regular business hours: 8am-5pm EST, M-F. 9 WARRANTY & TECHNICAL SUPPORT

CONTACT US: For more information, visit pyramidtimesystems.com or call our technical support team at 888.479.764 during regular business hours: 8am-5pm EST, Monday-Friday. Copyright 08 Pyramid Time Systems, LLC. All rights reserved. I00 Rev. J