Digital SWIR Scanning Laser Doppler Vibrometer Scan-Series OptoMET Scanning SWIR Laser Doppler Vibrometer (SLDV) is used for non-contact measurement, visualization and analysis of structural vibrations. It determines the Operational Deflection Shapes and Eigenmodes as easily as taking a video. Entire surfaces can be scanned automatically using flexible measurement grids. This powerful scanning system offers state-of-the-art digital signal processing Technology with extensive software for data acquisition, 3-D visualization and analysis. non-contact and non-reactive This system is non-contact, so there is no need to attach sensors or run cables. Measurements can be made from close up to large working distances. Very compact and easy to operate The scanning system is very compact with a modern All-in-One design. Only a single USB connection to a PC or Laptop is needed to start a measurement. Latest Scanning Technology You get a build-in full HD 30 x zoom camera for Pin sharp video. Large Objects can be captured with a large aperture and low-noise scanner providing a 50 x 40 scan area. High-Speed measurements You can measure velocities up to 24.5 m/s. Excellent signal level With its new stabilized SWIR laser you get a very good signal-to-noise ratio on all technical and organic surfaces. The vibrometer is laser safety Class 2 - safe operation without laser safety restrictions. Highest accuracy and resolution Due to our ultra fast Digital Signal Processing the vibrometer achieves highest accuracy in combination with an outstanding resolution up to 4 nm/s for velocity and 4 pm for displacement. Large working distance Thanks to its powerful SWIR laser measurements can be made accurately from large working distance, for example to measure a bridge, an airplane or a ship etc..
Applications Acoustics Consumer market: Development of household appliance, electronic toothbrush, washing machine... Automotive industry: Optimization of car door, automotive transmission, brakes, motor, or NVH testing.... Optimization of deflection shapes in Loudspeaker, er, musical instruments Structrual Dynamics Automotive tive industry: Modal analysis, s, FE-model validation Aviation and Aerospace industry: Airplane components, on turbine Material Research: non-destructive tive evaluation atio of material properties Example applications: Automotive industry Aerospace industry Medical technology Material research & testing Consumer markt Structrual dynamik helicopter
Making Measurements Geometry Definition Mesh Generate / Import Start scanning Results / 3D Animation FEM model validation Data Export Set up Analyze - Geometry definition - Mesh generation / import - Setup of the data acquisition / generator system Automatic Scan - The whole grid is automatically scanned by the laser beam. - making measurements at each grid point - Time response and frequency response of each point and reference signals are displayed in real time during the scan. Visualization / Analysis - 3D Animation to display your ODS (Operation deflection shape) - Modal analysis - Data export - FEM model validation
General technical data Measured quantity Signal processing Maximum velocity Number of measurement ranges Vibration resolution Frequency bandwidth Laser wavelength Laser safety class Working distance velocity, displacement, acceleration Digital (OptoMET UltraDSP Technology) up to 24.5 m/s up to 14 for velocity / 19 for displacement up to 4 nm/s / 4 pm 0 Hz - Measurement laser: 1550 nm, Targeting laser: ~ 515 nm Measurement laser: output power: <10 mw, eye-safe, class I Targeting laser: output power: <1 mw, eye-safe, class II up to 100 m Scan angle [h x v] 50 x 40 Scanner properties angular resolution < 0.002 Scan point density Camera up to 512 x 512 scan points Full HD 1080p, 30x optical zoom, horizontal viewing angle: 63.7 (wide end) to 2.3 (tele end) Computer interface USB 3.0 BNC analog outputs BNC analog inputs User interface output User interface input displacement / velocity / acceleration output, signal-generator output measurement input, reference input, optional: reference input2 24-bit A/D converter per channel support for IEPE (Integrated Electronic Piezoelectric) inputs color screen 3.5" + 20 segment LED bargraph touch screen, knobs with push-button, key switch (power) Operating temperature range +5... 40 C Dimensions Weight Power supply Measurement and Analysis Software length x width x height (excluding handle): 450 x 224 x 180 mm 12 kg 110-240 V AC (50-60 Hz) or 15 V DC - CCD-Picture capture, Live Display - Geometry and Measurement Point Editor - FFT Analyzer with extensive functionality - Mirror control and steering - Operation Deflection shapes (ODS) - Animation, AVI-Export - UFF, ASCII and MatLab- Export - Free Offline-Version to use in office - Modal analysis module optional - Operation system: Microsoft Windows Laseretikett DO NOT STARE INTO BEAM Class 2 Laser Product Laser CLASS 1: invisible, 1550 nm, output power: <10 mw Laser CLASS 2: visible, green laser beam, 515 nm. output power: <1 mw
Scan-Series configuration Model Scan-Basis Scan-Sense Scan-Master Decoder Number of ranges Max. Frequency Ranges (Peak) Best Resolution D-VD-1S 8 24.5 mm/s - 5 m/s 4 nm/s D-DD-1S 19 ±122.5 nm - ± 122.5 mm 4 pm D-VD-2S 12 2.45 mm/s - 12 m/s 4 nm/s D-DD-2S 19 ±122.5 nm - ± 122.5 mm 4 pm D-VD-5S 14 2.45 mm/s - 24.5 m/s 4 nm/s D-DD-5S 19 ±122.5 nm - ± 122.5 mm 4 pm Dimension of the Scanning Vibrometer : 450,4 112 224 180 3 x 3/8-16 UNC 20 40