Adebutaniser in BP s FCC unit

Similar documents
Achieve Challenging Targets in Propylene Yield using Ultra System Fractionation Trays

Around 1810 the French inventor Cellier-

HIGH-PERFORMANCE ANTI-FOULING TRAY TECHNOLOGY and ITS APPLICATION IN THE CHEMICAL INDUSTRY

Tray Specification. AlphaTRAY DESIGN SHEET. Standard Types: High Performance Types: DS-DT-01 Rev 3 OVERVIEW

Troubleshooting and Rectification of a Giant C 3 Splitter Tower Problem

Operating System Required: Windows 95/98, Me, XP Home, XP Pro Windows NT, DOS Version available upon request

Effect of Downcomers Sizes on Tray Column Performance

SUPERFRAC High Performance Trays

ALDEN COMPUTATIONAL ANALYSIS OF WESTFALL S OPEN CHANNEL MIXER FOR THE COLBORNE SEWAGE TREATMENT PLANT. Solving Flow Problems Since 1894

Tracer Technology Provides Insight Into Leaking Trays And Entrainment

Passive ECC Penetration Duct

44 th Annual Canadian Mineral Processors Operators Conference Ottawa, Ontario, January 17-19, 2012

MAKE HAZARD ANALYSES BETTER SINGLE-USE DEVICES GAIN PERMANENT PLACE PATH FOR PROCESS SAFETY EMERGES

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S

ELECTRICAL SAFETY INSPECTION REPORT. MTM Garments Ltd.

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

800 Displaying Series Flowmeter

Structural Plate Design Guide. 5 th Edition MULTI-PLATE. Aluminum Structural Plate. Aluminum Box Culvert SUPER-SPAN SUPER-PLATE.

Nominal Feet Feet List Price Pipe Item # I.D. x Length O.D. Per Bag Per Crate Per 100 Feet

THE DESIGN OF A LEAD-BISMUTH TARGET SYSTEM WITH A DUAL INJECTION TUBE

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

VAM 21 VAM TOP HT VAM FJL VAM HTF DINO VAM VAM HW ST VAM MUST

UPU 5000 Inline Delamination Detection and Process Trending with the Ultrasonic Measuring System

Couplings. Quick Release

Projector solutions. Display size matters in education

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Laminar Design Screen Basket

JuCaTec JUMBO ELECTRODE TECHNOLOGY FOR COPPER ELECTROWINNING

THE CABLE TRAY SYSTEM

PRODUCT OVERVIEW PPLICTIONS SCREENERS & SEPRTORS The Cleveland Vibrator Company offers a wide range of light, medium and heavy-duty vibratory screener

TEXAS LOTTERY COMMISSION REQUEST FOR PROPOSALS FOR DRAWING STUDIO AND PRODUCTION SERVICES # RESPONSES TO PROPOSERS QUESTIONS

MODIFIED ASTM E814/UL 1479 FIRE RESISTANCE FOR FEDERAL CONSERVATION INC. ON AIRKRETE WALL PANEL TESTED: February 21, 2008 VTEC #

Figure 2 Horizontal batch mixer data sheet Date: Name: Company: Address: Phone: Fax: Project Name: Material description: Material characterist

WATER/RECYCLED FIFM Complex Works Assessment Sheet

In batch mixing, ingredients are loaded into the mixer, the. What to consider when choosing a horizontal batch mixer

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1

Digital Video Engineering Professional Certification Competencies

New Results on the Electron Cloud at the Los Alamos PSR

Sub-Synchronous PLACE Vibration FOR TITLE on Centrifugal Compressor with Tilt-Pad AUTHORS

In-Line or 75 Ohm In-Line

Contact data Anthony Lyons, AGELLIS Group AB, Tellusgatan 15, Lund, Sweden. Telefone:

Screw pump Series ALLFUEL AFT

THE RELATIONSHIP OF BURR HEIGHT AND BLANKING FORCE WITH CLEARANCE IN THE BLANKING PROCESS OF AA5754 ALUMINIUM ALLOY

VAM 21 VAM TOP HT VAM FJL VAM HTF DINO VAM VAM HW ST VAM MUST

Part No./ 型号 : RGB-Controller-101

The long term future of UHF spectrum

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

metrotile Roofing for Conservatories The No Drama Roof Including new-build conservatories and solid roof conversions 07/4470

Implementation of MPEG-2 Trick Modes

DOME OPTIC SPLICE CLOSURE

GLog Users Manual.

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

Aqua Turf International, Inc.

Automatic Test System AT-S + with STAR + Technology Features

Other funding sources. Amount requested/awarded: $200,000 This is matching funding per the CASC SCRI project

Integrated Precision Harvesting System: A Promising Technology to Improve Berry Yield and Quality. Precision Agriculture Research Team

How Wire Fails Originally presented to the Society of Motion Picture and Television Engineers Convention, Sydney, Australia, on Friday, July 4, 1997.

SPECIFICATION. Spec No : VSS-1402-CS603B

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

SAFETY WARNINGS AND GUIDELINES... 3 INTRODUCTION... 4 CUSTOMER SERVICE... 4 PACKAGE CONTENTS... 4 RECOMMENDED TOOLS... 6 CONTROL PANEL OVERVIEW...

Oak Ridge Spallation Neutron Source Proton Power Upgrade Project and Second Target Station Project

THE ULTIMATE DRY CHOICE

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 120,000 BTUH S9V2D120D5-SUB-1-EN. March 2016 S9V2D120D5PSAA TAG:

from ocean to cloud ADAPTING THE C&A PROCESS FOR COHERENT TECHNOLOGY

Using the List of Approved Assemblies

TruePlate Structural Plate

Concept of Operations (CONOPS)

Obtained from Omarshauntedtrail.com

The FiberMark1 offers an ideal solution for

Part 1: How to Avoid Confusion When Testing Insertion Loss According to TIA/EIA-568 B.1 and B.3

MINNEHAHA COUNTY ON-SITE WASTEWATER TREATMENT SITE EVALUATION WORKSHEET Form #1. Land Owner. Legal Description

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Twin City Fan & Blower

2/28/2018. Optimizing Cone Crusher Performance Jeff Gray. Three Focus Areas

DISTRIBUTION AMPLIFIER

MEGALEX Carbon fiber sucker rods 4/25/2011 1

NZQA unit standard version 3 Page 1 of 7. Demonstrate knowledge of telecommunications cable systems

Section 5.0: Lab Equipment and Setup

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

Gel-sealed in-line fiber optic closure

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

White Paper JBL s LSR Principle, RMC (Room Mode Correction) and the Monitoring Environment by John Eargle. Introduction and Background:

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

THE NEW CHOICE IN MANEUVERING

INDIAN INSTITUTE OF TECHNOLOGY ROORKEE NPTEL NPTEL ONLINE CERTIFICATION COURSE. Mechanical Operations. Lecture-09 Industrial screening equipment

Roots * RAS-J Air & RGS-J Gas Blowers. GE Energy

Improving Lightning Protection of Power Systems with Externally Gapped Line Arresters (EGLA)

Küba comfort DP. Draught-free ventilation and extremely quiet operation

KESTREL 2 SERIES. PRODUCT WHITE PAPER

ELECTRICAL SAFETY INSPECTION REPORT

HD Review March 30, 2011 Franz Klein

Dynamic Performance Requirements for Phasor Meausrement Units

Answer any FIVE questions

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Model Material Lamp type LED color Voltage Distribution Lens

Television Audio Remastering Device

Linear flow controls VFC Linear flow controls with actuator IFC

Power Injector 1520 Series

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

Transcription:

Better feed entry ups debutaniser capacity Points of transition, where streams enter or leave the tower, are some of the most common and severe tower bottlenecks. Combining hydraulic evaluation with field data and gamma scan analysis is key to identifying and eliminating such bottlenecks Henry Z Kister Fluor, Aliso Viejo, CA, USA David E Grich and Ryan Yeley BP America Inc, Texas City, USA Adebutaniser in BP s FCC unit (Figure 1) separates 57 000bpd of feed into a C 4 overhead product and a bottom debutanised naphtha product. The bottom product is purified to a Reid vapour pressure (Rvp) specification typically of about 7psi. The tower is 10.5ft ID and contains trays, with the two-phase feed entering above tray. For several years, the tower bottlenecked the gas plant. Raising the charge rate or the tower reflux would lead to tower flooding, and the flooding would lead to high tower pressure drops, instability and poor separation. With an FCC turnaround scheduled for February 2003, work began in late August 2002 to troubleshoot and debottleneck the tower. The joint investigation identified the arrangement of the tower internal feed piping to be the primary bottleneck. Secondary bottlenecks marked for improvement were excessive liquid height on the bottom chimney tray and tight downcomer entrance areas below the feed. The investigation was completed within one month with a full definition of the proposed modifications to tower internals. Vendor drawing checks were completed by the end of November 2002. The modifications were implemented in the February 2003 turnaround. Upon return to service, the tower bottleneck no longer existed. Flooding, instability and high-pressure drops are no longer observed at the current plant rates. Product purity has improved, with the bottoms RVP 1psi lower than before the modifications. The debutaniser no longer bottlenecks the FCC gas plant. Hydraulic evaluation Based on normal operating data at unflooded conditions, a simulation was prepared and provided the basis for a hydraulic evaluation. Results of this hydraulic evaluation are shown in Table 1, which shows that none of the trays in 57 000 BPD 27% wt vapour Figure 1 FCC debutaniser the debutaniser approached either jet flood or downcomer backup flood. For prediction of downcomer choke flood, two methods were used: method 1, interpolation of FRI data, and method 2, a correlation that tends to be conservative. Since method 1 interpolates hydrocarbon test data, it is the most accurate. Table 1 shows that even with the more conservative predictions, trays 2 and 16 operated well away from downcomer choke flood. For Tray 28, while our interpolation method shows that downcomer choke flood is unlikely, the more conservative method raised concerns about flooding. These concerns were supported by the high downcomer entrance velocity of 1 14 22 C.W. 20 000 BPD FC TC LC Steam C 4 s Debutanised naphtha 0.52ft/sec on tray 28, which neared the good practice limit [0.5-0.6ft/sec, per p290 of Kister s Distillation Design, McGraw-Hill, NY, 1992]. The downcomer entrance velocities on tray 16 (0.44ft/sec) and tray 2 (0.31ft/sec) were well within the good practice limit. Overall, hydraulic analysis argued against regular tray or downcomer flooding causing the observed tower bottleneck. However, it did raise concerns that the lower trays in the tower, especially near tray 28, may approach a downcomer choke flood. With the hydraulic evaluation arguing against a regular tray/downcomer bottleneck, the investigation turned to tower gamma 31

Tower diameter, ft 10.5 Type of tray Valve trays, containing uncaged round valves Initial trays Modified #2 #16 #28 #16 #28 Tray spacing, in 24 Weir height, in 3 3 3 3 3 DC clearance, in, side 2.5 2.5 2.5 3.25 3.25 centre 2.5 2.5 2.5 2.5 2.5 Open slot area, % (1) 13 12.5 12 13 12 13 DC width, top/bot, in, side 12/9 16/13 20/13 centre 10/6 14.5/9 20/11 DC area, top/bot, ft 2, side 8.4/5.5 13/9 18/10 centre 8.7/5.3 13/8 18/10 Bubbling area, ft 2 69 62 59 Free area, ft 2 78 74 69 Weir length, top, in, each 106 113 92 (3) C f, ft/sec (2) 0.22 0.13 0.19 0.14 0.20 gpm/in outlet weir (3) 5.6 11 13 14 16 DC inlet velocity, ft/sec 0.31 0.44 0.52 0.32 0.38 % Jet flood 55 39 56 42 60 % Froth in downcomer 56 56 69 50 58 % DC choke flood, method 1 71 55 72 51 67 % DC choke flood, method 2 90 79 103 68 89 Notes: 1. Expressed as a % of tray active area. ρ v 2. C f = u f ρ L ρv where u is velocity, ft/sec, p is density lb/ft 3, and L and V signify liquid and vapour, respectively, f denotes based on the free area; ie, on the tower area less the downcomer top area. 3. Swept-back weirs in the initial design, chordal weirs in modified design. 4. Gamma scan observations. Table 1 Hydraulic evaluation and debottlenecking of the debutaniser trays and downcomers scans in search for clues for the nature of the bottleneck. The tower was scanned six years earlier, in August 1996. A close review showed that tower charge rates and operating conditions at the time of the scan were similar to those six years later (ie, during current investigation). The six-year-old gamma scans were therefore suitable for the current investigation, eliminating the need for tower rescan. Two active area scans were shot in 1996: one scan at normal reflux rate (19 MBD), the other at increased reflux rate (24 MBD). Since the reboiler outlet temperature was left on control (Figure 1), this increase in reflux affected a matching increase in boil-up from 47000 490001b/h. The corresponding increases in loads were approximately 23% (liquid) and 14% (vapour) above the feed, and 3% (liquid) and 5% (vapour) below the feed. In the normal reflux rate scan (Figure 2), trays 1 through appeared to be operating normally. Froth heights, even according to the most conservative estimates, were well below the tray spacings. No liquid was visible in the vapour spaces of trays below the feed. Above the feed, a small, yet significant amount of liquid was visible in the vapour spaces above the froths. In the increased reflux rate scan, the feed tray () and those above it, as well as 16 and 18 below the feed, were flooded. Trays 17, 19, 20, 22, 24 and 26 below the feed were either flooded, or at least heavily loaded, with froth heights typically 10in taller than those measured in the normal reflux rate scan. Froth heights for the centre-to-side flow trays in this section were typically 5 inches taller than froth heights for the side-to-centre flow trays. This froth height difference occurred only at the Overall, hydraulic analysis argued against regular tray or downcomer flooding causing the observed tower bottleneck. However, it did raise concerns that the lower trays in the tower, especially near tray 28, may approach a downcomer choke flood increased reflux rate. As one descends from tray 18, the flooding and froth heights appeared to progressively ease off. Trays 27 through operated normally, or almost normally. Tray and the chimney tray appear identical in the normal reflux and in the increased reflux scans. The froth height on the chimney tray was estimated to be close to the top of the chimneys. Locating the trouble spot Since flooding propagates up the tower, the gamma scan established conclusively that the flood initiated below the feed. The flooding observed above the feed was liquid accumulating up from the point at which flooding initiated. This point is most likely to be tray 16, the first centre-to-side flow tray below the feed, but this could not be established with total confidence. Other centre-to-side flow trays just below the feed were also either at flood or on the verge of flood. For these trays, the flood was less severe and therefore only propagated to the next higher tray. The flood was shown to be the most severe immediately below the feed and eased off as one descended the stripping section. This is the converse of the change in vapour and liquid loads (Table 1). The simulation gave vapour and liquid loads on trays 28 29, which were % and 17%, respectively, higher than those on trays 16 17. The initiation of flood in this low-loading region argued strongly against a regular flood mechanism, which occurs at the point where vapour and/or liquid loadings are highest. Pressure drop measurements concurred with flood initiation below the feed. Tower pressure drop during the increased reflux rate scan was 4psi higher than it was during the normal reflux rate scan. With the median froth density about 20lb/ft 3 (per Figure 2), a 4psi pressure drop rise coincides with a total of about 35 40ft of froth. This supports flooding from just below the feed all the way to the top of the tower, as seen on the gamma scans. The observation that, at normal reflux, froth heights on the bottom trays were well below the in tray spacing, with clear vapour above, means that these trays did not operate close to jet flood. The observation that these trays went into flood upon a 5% increase in vapour load establishes conclusively that the flood propagated via a downcomer mechanism. Although the liquid height on the chimney tray approached the top of the chimneys, the gamma scans argue against a link between a chimney tray bottleneck and the flooding observed in the tower. The liquid level on the 32

chimney tray appeared quite sharp, and there was almost 2ft of entirely clear vapour above the chimneys. Trays 27 through above the chimney tray were not flooded and appeared almost identical in the increased and normal reflux scans. The gamma scans showed no sign of a bottleneck in this region. In summary, the analysis pointed at a premature, abnormal flood initiating just below the feed. This flood propagated via a downcomer mechanism. Focus on feed entry The previously discussed findings shifted the focus to the tower feed. Fluor s survey of malfunctions in refinery fractionators [see PTQ, Autumn 2003] identified feed entry issues as a prime source of bottlenecks and premature flooding in debutanisers. To correctly simulate the feed, it was necessary to flash the feed stream by an outside flash step to the actual pressure of the feed tray. This yielded 27 wt% vapour. The two-phase feed entered the space above tray via a 10 H-shaped pipe (Figure 3). The lateral arms of the H contained slots, pointed downward towards the tray floor. The total slot area was 0.89ft 2, giving a huge downward slot velocity of 33ft/sec based on the average mixed phase density. The corresponding slot p m V 2 was 6000, where p m is the mixed phase density, and V is the slot mixed phase velocity, ft/sec. The huge velocity pointed at the tray floor was identified as the prime bottleneck in this tower. The good design practice [Kister, Distillation Operation, McGraw-Hill, 1990] is to point the two-phase mixture towards the inlet downcomer at an angle of about 45 degrees downwards and to restrict the slot p m V 2 to less than about 1000 2000. The lower p m V 2 reduces the kinetic energy of the feed, and the downcomer wall spreads its momentum while minimising disturbance to the tray. The entry arrangement in Figure 3 is likely to cause excessive turbulence on the tray, re-entrainment of the feed, and penetration of the two-phase feed through the valves on the tray floor into the downcomer below. This penetration is likely to overload the trays immediately below the feed and to induce lights into the downcomer liquid of these trays. Both actions are likely to induce premature flood in the trays just below the feed, as observed in the scans. A secondary bottleneck was caused by excessive mixture velocity at the feed entry. At the tower 10 feed inlet nozzle, and throughout the 10 pipe from the nozzle to the H, the mixed twophased feed velocity was 54ft/sec, giving Distance, feet 0 5 10 20 25 35 40 45 50 55 60 65 70 75 80 85 90 a p m V 2 of 16 000. This is a huge number, an order of magnitude greater than good design practices. This high velocity is likely to generate high turbulence and lead to a poorly distributed feed. This high velocity is also likely to shatter liquid drops into tiny droplets, which are easily entrained, generate mist and can induce or promote premature flood. Poor distribution of the feed is likely to E-470 debutanizer tower 25 20 10 5 0 Density, lb/ft 2 Increased reflux Reflux (B) Feed (C) Reboiler rtn. Figure 2 BP Texas City refinery E-470 debutaniser tower scan 42" 21" 9" Figure 3 Feed entry before debottleneck #13 #14 # #16 #17 Normal reflux 17" 21" 2.5" 2.5" 3" 2.5" raise some of the local slot velocities well above the 33ft/sec mentioned previously, thus aggravating the primary bottleneck. Bottom chimney tray bottleneck Liquid from the bottom tray of the debutaniser is collected on a chimney tray just below it, from where it flows to B C E 9" 13" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 21 22 23 24 25 26 27 28 29 CT 33

liquid draw Reboiler return #29 # 20" 22" 16" 18" 5" 16" 3" 48" chimney tray was effectively degassing the liquid. The total degassing time on this chimney tray was about 20 seconds, which is on the low side [ 60 seconds is good per Kister, Distillation Operation, McGraw-Hill, 1990]. However, considering that the tray downcomers provided an additional four seconds of degassing time, and that there was no waterfall from the seal pan overflow to the liquid level (such waterfall produces froth), it is conceivable that the liquid drawn was sufficiently degassed. Accordingly, the chimney tray was identified as a secondary bottleneck, which was not encountered at the current operating conditions. Figure 4 Bottom chimney tray Figure 5 Feed entry modification a once-through thermosiphon reboiler (Figure 1). There were concerns that the bottom chimney tray may be another bottleneck due to its non-standard design. These concerns were supported by the gamma scan observation that the liquid level on the tray approached the top of the chimneys. The fractionator malfunction survey [see PTQ Autumn 2003] lists reboiler-draw arrangements as a major trouble spot in debutanisers. It was therefore imperative to investigate these concerns. Figure 4 shows this non-standard design. The top of the outlet draw nozzle from this tray is elevated 12 above the tray floor, with the chimneys only 16 tall. Liquid velocity in this draw nozzle was extremely high (9ft/sec) and it is badly undersized for self-venting flow. It is therefore conceivable that the liquid level on the chimney tray may exceed the top of the chimneys. Liquid level rising above the New top of the chimneys can lead to entrainment and premature flooding in the section above. Also, some of the tray liquid can descend down the chimneys, starving the reboiler of liquid. The gamma scans, as well as operating experience, however, showed that even at the increased reflux rates the chimney tray bottleneck had not been reached yet. The chimney tray draw provided the only path of liquid from the tower to the reboiler, and the reboiler did not show any limits. This means that not much liquid descended down the chimneys, and most of the liquid actually went into the liquid draw. According to the gamma scans, the liquid level does not rise significantly above the chimneys and does not produce significant entrainment. With the draw nozzle undersized for self-venting flow, the draw could handle most of the liquid flow rate only if the Debutaniser debottleneck The previous analysis identified one primary bottleneck, which was theorised to be the root cause of the premature flood in the tower, and three secondary bottlenecks, which appeared not to have been reached yet. The primary bottleneck was the downward pointing of the distributor slots towards the tray deck and the high velocity (33ft/sec) at which this feed hit the tray deck (a twentieth of a second after it left the distributor slots). It is likely that some of this feed penetrated through valves on the tray floor into the trays below, inducing excessive hydraulic loads and forcing lights into downcomers. Since the side downcomers on the trays below the feed were wider than those above the feed, and the feed pipe was close to the wall of one of the narrow downcomers, some of the feed penetrating the tray deck was directed right into the downcomer below. The lights and vapour entering these lower downcomers were likely to have induced premature downcomer choke in them. To debottleneck the feed entry, the distributor slots needed redirecting away from the tray floor and the slot velocity needed to be lowered. This was achieved by replacing the slotted arms of the H shown in Figure 3 with new pipes equipped with slots that were directed at degrees from the horizontal towards the downcomer wall (Figure 5). This angle was slightly flatter than the conventional 45-degree angle in order to assist vapour disengagement from the mixed feed. The total slot area was increased from 0.89 2ft 2, which reduced the mixture average slot velocities toft/sec and the slot p m V 2 to about 1200. These numbers are well within good design criteria. Impingement baffles were installed to prevent direct impingement of the feed on the downcomers from tray 14. Three secondary bottlenecks were identified. Although none of these 34

appeared to bottleneck the tower at the current rates, each could become a major bottleneck once the primary bottleneck was eliminated. Budgets and economics favoured modification to address the secondary bottlenecks as long as costs were not prohibitive. The secondary bottlenecks, and corrective action taken, were: Lower trays in the tower approaching a downcomer choke limit. To address this bottleneck, the trays below the feed were replaced by new trays with 38% greater downcomer entrance area, at the expense of 5% reduction in the bubbling area, steeper downcomer slopes and weir-type change from swept-back to chordal. At the tray supplier initiative, clearances under the side downcomers were opened to reduce downcomer backup. Details of the modified trays are in Table 1. Besides alleviating concerns about downcomer choke flood, this modification brought the downcomer inlet velocities to within recommended design criteria. The tray changes were relatively inexpensive, using commercial adapters (Z-bars) to avoid hot work on the tower shell. Liquid level on the chimney tray approaching the top of the chimneys. This bottleneck was eliminated by raising chimney heights by 18in. The top of the chimneys is now 34in above the tray floor, well above the liquid level. Excessive two-phase mixture velocities at the feed nozzle and the pipe from the nozzle to the H. The modification needed to alleviate this bottleneck is to cut a larger nozzle at the tower shell. Due to metallurgical requirements, this modification was expensive and could not be economically justified. This bottleneck, therefore, was not modified. Results The process design for all the modifications was by the Fluor/BP team. Detailed drawings and fabrication were by a major tray supplier. The modifications were implemented at the February, 2003 turnaround. Upon return to service, the debutaniser no longer experienced premature flooding, instability and highpressure drops at the current plant rates. No limits were observed, although the tower feed rates have not been pushed far beyond the normal 57 000 BPD. Product purity has improved, with the bottom RVP consistently 1psi lower than previously. The debutaniser no longer bottlenecks the FCC gas plant. Acknowledgement The authors wish to express special thanks to Joy Hansen, BP, for her great direction of the investigation, to Tracerco for excellent gamma scans and for making its scans available for this article, to Tak Yamagi for contributions to the hydraulic design and to Altair Strickland for the field execution of the project. Henry Z Kister is a Fluor Corporation fellow and director of fractionation technology. He has over 25 years experience in design, control and start-up of fractionation processes and equipment. Kister obtained his BE and ME degrees from the University of New South Wales in Australia. E-mail: henry.kister@fluor.com David E Grich is a long-range optimisation engineer at BP America Inc in Texas City, Texas. Grich has a BE in chemical engineering from Youngstown State University. Ryan Yeley is an optimisation engineer at BP America Inc in Texas City, Texas. Yeley has a BS in chemical engineering from Texas A&M University. 35