File E Project 01NK7526. April 4, 2001 REPORT TELEMETERING EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS. Metrix Instrument Co.

Similar documents
LED Backlight for Technics amplifiers

MODEL HS35 DRAWWORKS OPTICAL ENCODER

Sensor technologies Proximity sensors Series ST4. Brochure

Selection matrix for electronic pressure switches

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

EXPlora. Introduction

Filters for Power Lines (Low Leakage Current)

Bimetal Temperature Switch

File E64388 Vol. 1 Sec. 106 Page 1 Issued: and Report Revised:

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Inductive sensor With analog output BI15-M30-LI-EXI

GOODMAN BENTLEY STEREOPHONIC STETHOSCOPE OPERATING INSTRUCTIONS

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

Smart-Encoder : Optical Incremental

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Pressure transmitter For applications in hazardous areas Model IS-3

RGB 5050 PixelControl LED Super Flat Rope Part Numbers: PSFR-RGB-W-20

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

RSH27 Nixie Tube Socket with LED

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

PMG. Vibration Energy Harvesters

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

APPLICATIONS. Automatic warehouse. Trasportation lines

SQM40/41 Actuators for air and gas dampers

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

WLB SERIES HID Lighting for Hose Down Applications

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Power Injector 1520 Series

COVER PAGE FOR TEST REPORT

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

EZ Encoder : Optical Incremental (P Series)

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Trusted 40 Channel Analogue Input FTA

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

Standard signal metering in wall-mounting case

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

Smart encoders & actuators

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

Panel-mounting thermostats, type series EM

Product Data Sheet

SDI-MP1010-GM-60P-M-RA 3G/HD-SDI Output Video Transceiver. SDI-MP1010-GM-60P-M-RA Features. Block Diagram SDI-MP1010-GM-60P-M-RA.

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

Scotch Heavy Duty Vinyl Electrical Tape 22

Single Point Flow Monitor SW118 SW119

EZ Encoder : Optical Incremental

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

Explosion Proof Audible Signal db(a) Series YA60

IEPE Premium Accelerometer, Side Connector

Pivot Power RJ45 Modular Plug Connectors

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

XML LED X M L L E D. Explosionproof Linear LED Lighting

Interface Connectors for Miniature, Portable Terminal Devices

Read/write head TN-M18-H1147

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

TL8651 3G/HD-SDI Output Video Transceiver. TL8651 Features. Block Diagram TL8651 3G/HD-SDI. 1080p p50


Quick-disconnect cables. Adjustable mounting brackets

Read/Write Head TN-M30-H1147

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Panel-Mounted Thermostat

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

V 180 Series Photoelectric Switches

5530M and 5530MHV Adaptatone Installation Sheet

choice of types to suit many applications, from simple containers, toolboxes, industrial canister type vacuum cleaner, insulation

Installation Guide VL-MV10. Model No.

Electrical connection

Material: Weight: IP Rating: Cable: Connector:

Trusted TMR I/O SmartSlot Slot Cables

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Liner Quattro AC XB RGBW

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Inductive sensor NI3-EG08K-Y1-H1341

Model /29S RF Splitter

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

Quick-disconnect cables. Adjustable mounting brackets

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Pendant Light Fitting IEC Series 6470/2

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Transcription:

File E139529 Project 01NK7526 April 4, 2001 REPORT on TELEMETERING EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS Metrix Instrument Co. Houston, TX Copyright 2001 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety.

File E139529 Vol. 1 Sec. 2 Page 1 Issued: 2001-04-04 and Report Revised: 2010-04-29 DESCRIPTION PRODUCT COVERED: USL, CNL Models IT6810 and IT6811 followed by 00, followed by 1, 2, 3, or 0, may be followed by a four digit number, may be followed by a three digit number Impact Transmitter for Class I, Division 2, Groups A, B, C, and D Hazardous Locations NOTE: CNL = Canadian Standards - Listed USL = United States Standards - Listed ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE): * USL indicates investigation to United States UL 508 and ANSI/ISA 12.12.01-2007. CNL indicates investigation to Canadian Standards C22.2 No. 142-M1987 and C22.2 No. 213-M1987. GENERAL: Models IT6810 and IT6811 are impact transmitters that can be attached to machinery by a screw that runs through the center of the devices. These devices are used to sense vibrations that may be caused by pieces of the machinery coming loose. The constructions of Models IT6810 and IT6811 are identical except for the connectors that are provided. Models IT6810 and IT6811 with a MIL-C connector have been evaluated for nonincendive field wiring. All necessary entity parameters for nonincendive equipment and associated nonincendive field wiring apparatus are listed in Control Drawing 9683. See ILL. 24 for control drawing.

File E139529 Vol. 1 Sec. 2 Page 2 Issued: 4-4-01 and Report Revised: 8-26-02 NOMENCLATURE: Impact Transmitter IT6810 00 0 XXXX XXX I II III IV V I Basic prefix for all models * IT6810 No cable provided * IT6811 Cable provided II Standard on all models III RPM 00 - Standard 1 Low = 300 RPM 2 Mid = 600 RPM 3 High = 1200 RPM 0 Specify IV RPM in increments Blank This position is left blank if there is a 1, 2, or 3 in position III. XXXX RPM given in 10 RPM increments V Threshold in increments Blank This position is left blank if there is a 1, 2, or 3 in position III. * VI - Cable Length XXX Threshold given in 0.5 G increments Blank This position is left blank for Model IT6810. XXX Cable length for Model IT6811 given in 0.1 m increments.

File E139529 Vol. 1 Sec. 2 Page 3 Issued: 2001-04-04 and Report Revised: 2010-04-29 ELECTRICAL RATINGS: Transmitter supply voltage 15 to 30 Vdc Output current 4 to 20 ma Maximum ambient temperature: +100 C MARKINGS: General - The impact transmitter will bear the following markings. 1. Manufacturer's name and part number. 2. Hazardous Location, Classes, Groups and Division as shown under "Product Covered". 3. The Underwriters Laboratories' Listing Mark as described on the Listing Mark Data Page. 4. Applicable electrical ratings as described under "Electrical Ratings". 5. Ambient temperature: -40 C to +100 C 6. Temperature Code: T4A or T4 7. Date Code or Serial Number. INSTALLATION INSTRUCTIONS: The following statements are included in the installation instructions provided with the product. 1. This apparatus is suitable for use in Class I, Division 2, Groups A, B, C, and D, or unclassified or non-hazardous locations. 2. WARNING: EXPLOSION HAZARD. DO NOT DISCONNECT WHILE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITIBLE CONCENTRATIONS. 3. WARNING: SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR DIVISION 2. CONSTRUCTION DETAILS: General - The construction details are shown in the following photographs, associated descriptive pages and illustrations. The general shape and arrangement shall be shown in the photographs unless variations are specifically indicated.

File E139529 Vol. 1 Sec. 2 Page 4 Issued: 2001-04-04 and Report Revised: 2010-04-29 MODEL IT6810 IMPACT TRANSMITTER 1. Cover 303 stainless steel, 1-3/4 in. hexagonal shape with a height of approx 1-31/50 in. Provided with 9/32 in. hole that runs through the center of the device for the insertion of the screw, Item 3. See ILLS. 1, 1A, 2, and 5. 2. Lid - Overall dimensions of 1-5/8 in. diameter by 1/25 in. thick. Welded to cover. Provided with two tapped holes for screws that are used in connection with potentiometers. See ILL. 4. 3. Screw 1/4-28 UNF socket head cap screw. Dimensions shown in ILL. 3. 4. Accelerometer Connected to the circuit boards by two wires. For dimensions and parts, see ILLS. 8 and 9. 5. Connector See ILLS. 6 and 7 for Model IT6810 and ILLS. 22 and 23 for Model IT6811. IT68ll is for use with Listed (QPTZ) PLTC cable manufactured by Alpha, mechanically secured by threads. 6. Make/Break Components Potentiometers R15, R16, R11, and R9. Located in nonincendive circuits. 7. Potting Compound RTV, rated 180 C (Relied on only for placement of components when device is assembled, not relied on for spacings or protection method).

The following pages are the prior revisions of this certificate. 8824 Fallbrook Drive, Houston, Texas 77064 1.800.638.7494 www.metrixvibration.com info@metrixvibration.com