Control & Automation Overview. Behind every project, technologies and expertise. Timers. Control relays. Counters and Ratemeters

Similar documents
A / At MAR1 24 V c / 24 C 240 V a B Relay 1 x 8 A changeover 0.1 s C 100 h

Close supervision. Simplicity of use. Productivity gains. Control relay. C-Lynx. Instinctive control

Micro-control. Control system solutions adapted to your applications. Overview. b Logic controllers. b Control relays. b Timers.

Micro-control. Control system solutions adapted to your applications. b Logic controllers.

02/11/2015

Multifunction devices

Hour Meters / Timers, electronic

Preset counters, electronic

Time meter electronic

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

02/11/2015

Catalogue Ignitors and power switches for HID

Preset counters, electronic

Level Measurement silometer FMC 420, FMC 423

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Multifunction Digital Timer

Multi-functional safety relay modules PROTECT SRB-E

Eaton Durant. Counters, process instruments and hour meters.

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

PRINCIPLES AND APPLICATIONS

Kuhnke Technical Data. Contact Details

Solid-State Digital Timer

AF-300 E11 Adjustable Frequency Drive

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

G1-M1 (Protection Relay)

Assembly. Front view. LEDs. Parametrization interface. Power Bus

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Series CT7N Bimetallic Overload Relays

Counting and Process Technology 2009 / 2010

Capacitance Limit Detection nivotester FTC 420/421/422

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Timer and switching relays Timers. Function timer relay. Additional function relay. Timer and switching relay

Simply clever! The digital DIN-rail time switches by Grässlin

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Electrical connection

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Gamma instabus. Technical product information

Data Acquisition Networks. Installing and Configuring the DM01 Hardware



15 Series - Dimmer

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Pulse Counters, electronic

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Process Transmitter RMA 422

Datasheet - SRB-E-201ST

ALLEN BRADLEY TIMING RELAY

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

Dimming actuators GDA-4K KNX GDA-8K KNX

Time-Lag Relays. User s Handbook (General Model)

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Preset counters, electronic

Operating Instructions

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

Ordering details. Approval. Classification

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

High performance circuit breakers

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Model Number Structure

multi-function meters

Digital Input Modules for Compact FieldPoint

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Datasheet - SRB301LC 24VAC/DC

Photoelectrics Through-beam Type PA18C.T..., DC

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Modular Lube Lubrication Systems System Controls

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

STX Stairs lighting controller.

Process transmitter RMA422

XTM72E & F Real-Time Clock Modules

Operating instructions Electronic preset counter Type series 717

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor

DLP200M 2 Relay Module for Heating and Cooling Plants

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Absolute Encoders Multiturn

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

Operating instructions - High Performance LED Timer / / /

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

APPLICATIONS. Automatic warehouse. Trasportation lines

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Magnetic and Hydraulic-Magnetic Circuit Breaker

Solution Selection Guide

SAPLING WIRED SYSTEM

INSTALLATION & USER GUIDE

Transcription:

Timers Control relays Counters and Ratemeters Temperature controllers Safety relays Logic controllers Control & Automation Overview Behind every project, technologies and expertise www.crouzet.com

Contents Crouzet Control Presentation P. 4 Expertise P. 6 P. 4-7 Timers The basics P. 10 Applications P. 12 Selection guide P. 14 Function diagrams P. 20 DIN rail mounted Panel mounted P. 9-24 Timers Control relays The basics P. 26 Applications P. 28 Selection guide P. 30 Modular casing Industrial casing P. 25-36 Control relays Counters and Ratemeters The basics P. 38 Applications P. 40 Selection guide P. 42 Connection diagrams P. 48 Electronic Electromechanical P. 37-50 Counters and Ratemeters Temperature controllers The basics P. 52 Applications P. 54 Selection guide P. 56 Digital Accessories P. 51-58 Temperature controllers Safety relays The basics P. 60 Selection guide P. 62 Applications P. 64 Relevelling control Machine safety P. 59-66 Safety relays Logic controllers The basics P. 66 Millenium 3 P. 69 The range P. 70 Accessories P. 71 Communication solutions P. 72 M3 Soft software P. 74 Function blocks P. 76 Applications P. 78 Selection guide P. 80 Millenium 3 Accessories P. 67-81 Logic controllers Part numbers index P. 82-91 To order: Customer Service Tel : 01 256 318 900 - info@crouzet.co.uk 2 I www.crouzet.com l Panorama Crouzet Control / Crouzet Automation 3

Presentation Widely recognised for over 50 years as the specialist in electromechanical, electronic technology and software engineering, Crouzet Control experience in time management, physical and mechanical values has resulted in an extensive automation components offer that includes logic controllers, timers, control relays, counters, ratemeters, machine safety equipment, and temperature controllers. Simple to use, Crouzet Control products are easy to program and install. With operations around the globe, Crouzet Control is constantly monitoring its customers' needs. Its sales teams, technicians and designers combine all their skills to adapt products to customer specifications, both in terms of the application and cost. Crouzet Control also ensures that its products are manufactured in compliance with quality and environmental standards (factories certified ISO 9001, 14001 and OHSAS 18001, eco-design). With its industrial and logistic flexibility Crouzet Control is able to deliver products, whether small-scale or mass production items, in the best possible timescale. Custom Sensors & Technologies (CST), is a specialist in sensing, control and motion products. Through its brands, BEI Kimco, BEI Sensors, BEI PSSC, Crouzet, Crydom, Kavlico, Newall and Systron Donner Inertial, CST offers customizable, reliable and efficient components for mission-critical systems in Aerospace & Defense, Transportation, Energy & Infrastructure, Medical, Food and Beverage and Building Equipment markets. Focused on premium value offers and committed to excellence, CST, with 4,400 employees worldwide and sales of $604M US in 2012, is the dependable and adaptable partner for the most demanding customers. www.cstsensors.com In this new Panorama, Crouzet Control presents: A new range of redesigned Safety Relays for machine safety applications with new functions and easy installation. Crouzet Control / Crouzet Automation team worldwide. New Chronos 2 timers (17.5 mm) substituting the existing range with an improved electronic and mechanical design allowing added robustness and reliability. Crouzet Automation, supported by an experienced sales and technical team and an easy-touse software, is the adaptable alternative for any automation solution. Crouzet Automation is the perfect solution for any specialized or demanding need. These products are specifically suited for integration in a wide range of applications such as waste and water treatment, access control, renewable energies, building equipment, industrial machines and transportation. Production Sales subsidiaries 4 I www.crouzet.com l Panorama Crouzet Control / Crouzet Automation 5

Expertise The Crouzet Control process In addition to high-performance products, advice and support, Crouzet Control offers tailor-made solutions for any application. A multi-skilled team Application-based marketing Electronic and software design Prototyping Mechanical engineering Production EMC tests and approvals Sales and logistics follow-up Analysis of customer requirements Expertise: UNDERSTANDING how applications work. Specific products Standard products Production INTEGRATING environmental constraints and quality requirements. PROPOSING technical and economic solutions which fully meet the needs of customers. Adapted products Products with added value Expertise: MEETING all needs, standard or specific, small-scale or mass production, thanks to the industrial flexibility of Crouzet's factories. GUARANTEEING the quality and reliability of products: all Crouzet s production sites are certified ISO 9001 and ISO 14001, and use quality tools such as 6 SIGMA. INTEGRATING eco-design into manufacturing processes to MINIMIZE the environmental impact of products throughout their life cycle. Customer Adaptation Centre and Design Office Expertise: Logistics and After-Sales Service CAPITALISING on the expertise of Crouzet engineers in mechanical, electrical and electronic engineering, software engineering and networks. Expertise: PROVIDING an optimum level of service ADAPTING products to ensure innovation and differentiation. DEVELOPING AND INDUSTRIALIZING custom products. and GUARANTEEING a prompt delivery schedule, whatever the type of order: small-scale or mass production, standard or adapted products. TRACKING all orders in real time on www.crouzet.com 6 I www.crouzet.com l Panorama Crouzet Control / Crouzet Automation 7

Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS 18001. Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the www.crouzet.com website offers the latest tools, available as free downloads, including, technical data sheets and installation manuals for each product. Timers Time management 8 I www.crouzet.com www.crouzet.com 9

The basics A timer How can it be defined in simple terms? A timer is a simple automation component which is used to manage actions over a period of time or control how long actions last.the timer is a control device which triggers an action according to a time and a function. After a predefined time has elapsed, the timer closes or opens one or more contacts. Timing cycles, whether single shot or repetitive, are started by latching inputs or pulsed inputs, allowing a wide variety of functions to be created. Crouzet Control, timers A panel mounted range and a DIN rail mounted range Timers Timing range 1 A timer To execute which actions? Triggering, Actuating A timer can be used to trigger an action according to a predefined time. It can also be used to stagger actions over a period of time. Delaying, Flashing In any time-related application, the timer can play a role and can be used to: Run installations according to times that can be adjusted by the user. Calibrate a machine running time. Allow or prevent an action. Delay an action. Manage stopping/starting of a motor, pump, etc. (star delta). Make an LED flash. Triggering Actuating Delaying Flashing In addition to this catalogue, the www.crouzet.com website offers technical data sheets and installation manuals for each product, available as free downloads. 815 timer Crouzet Control, timers Their features: Setpoint settings Mode Reset + enable Available in mono or multifunction versions (analogue or digital, with or without memory), to meet the specific needs of each application. A timing range of up to 9,999 hrs to cope with prolonged processing operations. MLR1 Time setting 1 Timing range 2 Time setting 2 Power supply LED A range of supply voltages from 12 to 240 V in one unit for optimised stocks. Recognised quality and reliability ensures the correct operation of equipment. 10 I www.crouzet.com l Panorama Crouzet Control 11

Applications Crouzet Control, timers Where are they found? Ice maker Managing the duration of refrigeration. Drink vending machine Timed management of delivery of drinks. In electrical cabinets associated with other automation functions for the following markets: Timers Food industry Industrial automation systems Lighting Building equipment HVAC Small or large industrial machines Timer TUR1, MUR1, MAR Timer TMR48, Timer 81x Packaging Controlling heat sealing times on blister packs, packaging bags, etc. Illuminated signs Managing flashing on illuminated signs. Lighting for mobile homes Managing the duration of outdoor lighting of a mobile home if the light switch is left switched on. Machine tools Control of maintenance periods. Timer MUR1, MXR1, mar1 Timer mlr timed impulse relay MXR Timer TMR48, Timer 81x Fan Time management for delayed fan start-up. Dosage Time management for distribution of glue, varnish... Sensing on assembly line Managing the operation of a conveyor belt based on the time interval between products on the belt. Remote machinery Managing maintenance of the power supply in the event of a mains power failure, switching on an external backup power source for a given time. Timer (TMR48, Timer 81x) timer MBR1 Timer MCR1 Timer TK2R1 12 I www.crouzet.com l Panorama Crouzet Control 13

Selection guide Chronos 2 DIN rail mounted, Timers DIN rail modular casings Casing width (mm) Connections Functions Type of output Output(s) Timing Supply Part number Type A / At / B / C / H / Ht Di / D / Ac / Bw 88 827 105 MUR1 17.5 Screw terminals A / At 88 827 115 MAR1 24 V c / 24 C 240 V a B Relay 1 x 8 A changeover 0.1 s C 100 h 88 827 125 MBR1 C 88 827 135 MCR1 H / Ht 88 827 145 MHR1 L / Li 12 V z 88 827 150 MLR4 24 V c / 24 C 240 V a 88 827 155 MLR1 Screw terminals A / At / B / C / H / Ht 12 V z 88 827 100 MUR4 17.5 Di / D / Ac / Bw 88 827 103 MUR3 Relay 1 x 8 A changeover 0.1 s C 100 h 12 C 240 V z Spring terminals 88 827 503 MURc3 Screw terminals Ad / Ah / N / O / P Pt / TL / Tt / W 24 V c / 24 C 240 V a 88 827 185 MXR1 A / At / B / C / H / Ht Di / D / Ac / Bw 24 C 240 V a 88 827 004 MUS2 17.5 Screw terminals A Solid state 0.7 A 0.1 s C 100 h 24 C 240 V z 88 827 014 MAS5 H / Ht 88 827 044 MHS2 24 C 240 V a L / Li 88 827 054 MLS2 240 V a 88 829 117 EMAR7 A 110 V a 88 829 112 EMAR2 17.5 Screw terminals Relay 1 x 5A changeover 0.1 s C 20 h 24 V z 88 829 119 EMAR9 A / At / B / C / H / Ht Di / D / W / Pe 17.5 Screw terminals Ac / Ad / Bw / Cx / N / O / Tt Relay 1 x 5 A changeover 0.1 s => 20 h 12 C 240 V c / 24 C 240 V a 12 C 240 V c / 24 C 240 V a 88 829 198 EMER8 88 829 108 EMYR8 Timers DIN rail industrial casings Casing width (mm) Connections Functions Type of output Output(s) Timing Supply Part number Type A / At / B / C / H / Ht Di / D / Ac / Bw 88 865 105 TUR1 A / At 88 865 115 TAR1 B 88 865 125 TBR1 22.5 Screw terminals C 1 x 8 A changeover 0.1 s C 100 h Relay 24 V c / 24 C 240 V a 88 865 135 TCR1 H / Ht 88 865 145 THR1 L / Li 88 865 155 TLR1 Q 88 865 175 TQR1 88 866 175* RQR1* K 2 x 8 A changeover 0.1 s C 160 s 88 865 265 TK2R1 1 x 8 A changeover 88 865 300 TU2R4 A / At / B / C / H / Ht 1 inst. or timed 8 A 12 V z Di / D / Ac / Bw 88 866 300* RU2R4* Screw terminals 1 x 8 A changeover 88 865 100 TUR4 22.5 Relay 0.1 s C 100 h 88 865 215 TA2R1 A / At 2 x 8 A changeover 24 V c / 24 C 240 V a 88 866 215* RA2R1* A / At / B / C / H / Ht 88 865 103 TUR3 1 x 8 A changeover 12 C 240 V z Spring terminals Di / D / Ac / Bw 88 865 503 TURc3 22.5 Screw terminals Ad / Ah / N / O / P Pt / TL / Tt / W Q A / At / B / C / H / Ht Di / D / Ac / Bw Relay 1 x 8 A changeover 1 inst. or timed 8 A 1 x 8 A changeover 1 x 8 A changeover 1 inst. or timed 8 A 0.1 s C 100 h 24 V c / 24 C 240 V a 230 C 440 V a 12 C 240 V z 24 V c / 24 C 240 V a * Available in 2014. The casing of the new range will be different from the ones presented here. Further information can be found on the data sheets available at www.crouzet.com 88 865 385 TX2R1 88 866 385* RX2R1* 88 865 185 TXR1 88 865 176 TQR6 88 866 176* RQR6* 88 865 303 TU2R3 88 866 303* RU2R3* 88 865 305 TU2R1 88 866 305* RU2R1* 14 I www.crouzet.com l Panorama Crouzet Control 15

Selection guide Plug-in industrial casings Casing width (mm) Connections Functions (detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type 35 35 21 Plug-in 8-pin base Plug-in 11-pin base Plug-in 8-pin base Plug-in 14-pin base A / At / B / C / H / Ht Di / D / Ac / Bw 1 x 8 A changeover 88 867 105 OUR1 A 2 x 8 A changeover 24 V c / 24 C 240 V a 88 867 215 OA2R1 C 88 867 135 OCR1 Relay 0.1s C 100 h L / Li 88 867 155 OLR1 A / At / B / C / H / Ht 1 x 8 A changeover 12 V z 88 867 100 OUR4 Di / D / Ac / Bw 12 C 240 V z 88 867 103 OUR3 A / At / B / C / H / Ht 1 x 8 A changeover Di / D / Ac / Bw 1 inst. or timed 8 A 88 867 305 PU2R1 A 24 V c / 24 C 240 V a 88 867 415 PA2R1 C Relay 2 x 8 A changeover 0.1s C 100 h 88 867 435 PC2R1 L / Li 88 867 455 PL2R1 A / At / B / C / H / Ht 1 x 8 A changeover 12 V z 88 867 300 PU2R4 Di / D / Ac / Bw 1 inst. or timed 8 A 12 C 240 V z 88 867 303 PU2R3 12 V c 88 895 201 RTMA2 24 V c 88 895 202 RTMA2 2 x 5 A changeover 24 V a 88 895 203 RTMA2 110 V a 88 895 206 RTMA2 A Relay 0.1s C 100 h 230 V a 88 895 207 RTMA2 12 V c 88 896 201 RTMA4 24 V c 88 896 202 RTMA4 4 x 3 A changeover 24 V a 88 896 203 RTMA4 110 V a 88 896 206 RTMA4 230 V a 88 896 207 RTMA4 Timers "Panel mounted", Timers Analogue - TMR48 series Digital Dimensions (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Supply Part number Type 48 x 48 Plug-in 11-pin base Plug-in 8-pin base L / Li - G / Gi 88 886 516 TMR 48 L 2 timed changeover A, B, C, W, G, Ac, Bw 88 886 016 TMR 48 U 2 x 5 A A 12 C 240 V c 88 886 106 TMR 48 A Relay 2 timed changeover or 24 C 240 V a A1, A2, H1, H2, Q1, Q2, D-Di 1 timed and 1 instantaneous 88 886 116 TMR 48 X (2 x 5 A) Dimensions (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Supply Part number Type 48 x 48 48 x 48 48 x 48 48 x 48 Plug-in 8-pin base Plug-in 11-pin base Plug-in 11-pin base Plug-in 8-pin base Plug-in 11-pin base A Relay 2 timed changeover 2 x 5 A A, B, C, D, Di, H 1 x 8 A timed changeover A, B, C, D, Di, H A1, A2, AM, AMt A1, A1C, A2, A2C, AM, AMt, B, BM, C, CM, D, Di, DiM, Dpause, H, HM, T,TM, W, WM Accessories available: base socket 8-pin for DIN Rail mount 25 622 130, base socket 11-pin for DIN Rail mount 25 622 080. Relay Relay 1 x 8 A timed changeover 2 timed changeover or 1 timed and 1 instantaneous (2 x 8 A) 2 timed changeover or 1 timed and 1 instantaneous (2 x 5 A) A, B, C, D, Di, H Relay 1 x 8 A timed changeover 24 V z 88 857 409 Timer 812 110 V a 88 857 406 Timer 812 220 C 240 V a 88 857 400 Timer 812 12 V c / 24 C 48 V z 88 857 003 Timer 814 24 V z / 110 C 240 V a 88 857 005 Timer 814 12 V c / 24 C 48 V z 88 857 103 Timer 814 24 V z / 110 C 240 V a 88 857 105 Timer 814 12 V c / 42 C 48 V z 88 857 302 Timer 815 24 V z / 110 V a 88 857 307 Timer 815 24 V c / 220 C 240 V a 88 857 301 Timer 815 12-24 V z / 100C240 V a 88 857 311 Timer 815E 24 V z / 48 V z 88 857 604 Timer 816 24 V z / 110 V a 88 857 607 Timer 816 24 V z / 220 C 240 V a 88 857 601 Timer 816 24 V z / 48 V z 88 857 704 Timer 816 24 V z / 110 V a 88 857 707 Timer 816 24 V z / 220 C 240 V a 88 857 701 Timer 816 The timer accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com 16 I www.crouzet.com l Panorama Crouzet Control 17

Selection guide MBA series Casing width (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type 22 (diameter) Screw terminals A Solid state 400 ma 22 (diameter) Screw terminals A Solid state 200 ma 0.1 s C 1 s 88 901 308 MBA2F 0.5 s C 10 s 88 901 328 MBA2F 3 s C 60 s 100 C 240 V z 88 901 348 MBA2F 0.5 min C 10 min 88 901 378 MBA2F 3 min C 60 min 88 901 398 MBA2F 0.1 s C 1 s 88 901 302 MBA3F 0.5 s C 10 s 88 901 322 MBA3F 3 s C 60 s 24 V c 88 901 342 MBA3F 0.5 min C 10 min 88 901 372 MBA3F 3 min C 60 min 88 901 392 MBA3F Timers Electromechanical - Top 2000 range Manual reset Casing width (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type 48 x 48 48 x 48 Casing width (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type 55 55 55 Screw terminals Plug-in 8-pin base Screw terminals Plug-in 8-pin base Faston connectors 6.35 mm Faston connectors 6.35 mm Faston connectors 6.35 mm 2-3-4 Relay 2-3-4 Relay A A A Relay Relay Relay 1 timed changeover and 1 timed instantaneous (2 x 5 A) 1 timed changeover and 1 timed instantaneous (2 x 5 A) 1 x 16 A timed changeover 2 x 16 A timed changeover 3 x 16 A timed changeover 6 s C 12 mn 6 mn C 12 h 24 V a 88 226 013 Top 2 000 42 C 48 V a 88 226 019 Top 2 000 110 C 127 V a 88 226 012 Top 2 000 220 C 240 V a 88 226 011 Top 2 000 24 V a 88 226 501 Top 2 000 42 C 48 V a 88 226 502 Top 2 000 110 C 127 V a 88 226 503 Top 2 000 220 C 240 V a 88 226 504 Top 2 000 24 V a 88 226 016 Top 2 000 24 V a 88 226 505 Top 2 000 42 C 48 V a 88 226 017 Top 2 000 42 C 48 V a 88 226 506 Top 2 000 110 C 127 V a 88 226 015 Top 2 000 110 C 127 V a 88 226 507 Top 2 000 220 C 240 V a 88 226 014 Top 2 000 220 C 240 V a 88 226 508 Top 2 000 5 min (Max.display time : 4 min 40 s) 88 256 401 88 256 4 15 min (Max.display time : 14 min) 88 256 402 88 256 4 30 min (Max.display time : 28 min) 88 256 403 88 256 4 60 min (Max.display time : 56 min) 127 / 230 V a 88 256 404 88 256 4 120 min (Max.display time : 1 h 53 min) 50 Hz 88 256 405 88 256 4 5 h (Max.display time : 4 h 43 min) 88 256 406 88 256 4 15 h (Max.display time : 14 h 10 min) 88 256 407 88 256 4 30 h (Max.display time : 28 h 20 min) 88 256 408 88 256 4 5 min (Max.display time : 4 min 40 s) 88 256 506 88 256 5 15 min (Max.display time : 14 min) 88 256 507 88 256 5 30 min (Max.display time : 28 min) 88 256 508 88 256 5 60 min (Max.display time : 56 min) 127 / 230 V a 88 256 509 88 256 5 120 min (Max.display time : 1 h 53 min) 50 Hz 88 256 510 88 256 5 5 h (Max.display time : 4 h 43 min) 88 256 511 88 256 5 15 h (Max.display time : 14 h 10 min) 88 256 512 88 256 5 30 h (Max.display time : 28 h 20 min) 88 256 513 88 256 5 5 min (Max.display time : 4 min 40 s) 88 256 906 88 256 9 15 min (Max.display time : 14 min) 88 256 907 88 256 9 30 min (Max.display time : 28 min) 88 256 908 88 256 9 60 min (Max.display time : 56 min) 127 / 230 V a 88 256 909 88 256 9 120 min (Max.display time : 1 h 53 min) 50 Hz 88 256 910 88 256 9 5 h (Max.display time : 4 h 43 min) 88 256 911 88 256 9 15 h (Max.display time : 14 h 10 min) 88 256 912 88 256 9 30 h (Max.display time : 28 h 20 min) 88 256 913 88 256 9 The timer accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com 18 I www.crouzet.com l Panorama Crouzet Control 19

Function diagrams U : Supply R : Output relay or load T : Timing : Infinity C (Y1) : Command Generic functions A function: Delay on energisation 1 relay Single shot timing which starts on energisation. Ac function: Timing after closing and opening of control contact 1 relay Ad function: Delay on energisation (cannot be reset) 1 relay After energisation, a control pulse or latching contact starts timing. At the end of timing, the output is excited. The output will be reset when a new control pulse or latching contact occurs. Ah function: Single shot flip-flop (cannot be reset) 2 timers or 2 relays including 1 instantaneous After energisation, closing of the control contact results in starting of the time delay T. Output relay "R" (or the load) changes state at the end of this time delay. After opening of contact C (Y1), relay "R" drops out after a second time delay T. After energisation, a control pulse or latching contact starts timing. At the end of timing, the output is excited. The time delay is then reset. At the end of this new time delay, the output reverts to its initial value. At function: Timing on energisation with memory AM function: Delay on energisation Latching during the time delay. AMt function: Delay on energisation Latching during and after the time delay. B function: Timing on impulse (one shot) - Shaping (cannot be reset) 1 relay After energisation, an impulse ( 50 ms) or a latching contact causes a change in state of the output relay "R" (or the load) which drops out at the end of timing. Bw function: Pulse output (adjustable) 1 relay 2 timers or 2 relays including 1 instantaneous On closing and opening of the control contact C (Y1), the output relay "R" (or the load) changes state for as long as the time delay lasts. C function: Timing after impulse True delay off (without auxiliary power supply) U : Supply R : Output relay or load T : Timing : Infinity C (Y1) : Command H function: Timing on energisation - Pulse output (adjustable) 1 relay On energisation, the output relay "R" (or the load) changes state, and stays there for the whole duration of the time delay and drops out at the end of the single shot cycle. Ht function: Delay on energisation with memory 1 relay Adds up the total opening time of a contact. On energisation, the output relay "R" (or the load) changes state, and stays there for the whole duration of the time delay and drops out at the end of the single shot cycle. K function: Delay on de-energisation True delay off (without auxiliary power supply) 1 relay L function: Asymmetrical flashing On energisation, the output relay "R" (or the load) changes state. On de-energisation timing starts and the relay "R" will only drop out at the end of this time delay. 1 relay Repetitive cycle with two times which can be set independently. 2 timers or 2 relays including 1 instantaneous Each time delay alternates with a different state of the output relay "R" (or the load). Note: The cycle starts with the relay "R"in the rest position. Li function: Asymmetrical flashing 1 relay Repetitive cycle with two times which can be set independently. P and Pe functions: Impulse counter (delay on) P function: Timing starts on energisation. At the end of timing, the output relay "R" (or the load) changes state for approximately 500 ms. Pe function: On energisation. At the end of timing, the output relay "R" (or the load) changes state for approximately 1 s. Pt function: Impulse counter (delay on) Q function: "Star-delta" starting TL function: Impulse relay Adds up the total opening time of a contact. At the end of timing, the output is excited for approximately 500 ms. On energisation, the "star" contact closes instantaneously and timing starts. At the end of timing the Ti "star" contact opens. After a pause of 40 to 100 ms the "delta" contact closes. After energisation, a control pulse or latching contact closes the relay. A second control pulse opens the relay. Timers 1 relay Adds up the opening time of a contact. Output relay "R" (or the load) changes state at the end of timing. A1 function: Delay on energisation 1 timer 1 instantaneous relay A2 function: Delay on energisation 2 timers. 1 relay After energisation, closing of the control contact C (Y1) results in the change of state of output relay "R" (or the load). Timing will only start when this contact opens. D or Di functions: Symmetrical flashing Repetitive cycle which alternately sets the output relay "R" (or the load) to operating and rest position for equal periods of time. 1 relay 1 relay D function: The cycle starts with relay "R" in rest position. Di function: The cycle starts with relay "R" in operating position. N function: "Safe-guard" O function: "Delayed safe-guard" On the first control pulse, the output is excited. If the interval between two impulses is longer than the timing value, this occurs normally and the output relay "R" (or the load) will change state at the end of timing. Otherwise, relay "R" stays in its original state until the condition is fulfilled. On energisation, a first timer runs and the output relay "R" (or the load) changes state. On the appearance of a control pulse, relay "R" returns to its initial position and stays there as long as the time interval between 2 impulses is less than the timing value. Otherwise, relay "R" will change state at the end of timing. Tt function: Timed impulse relay After energisation, a control pulse or latching contact closes the relay and starts timing. The relay opens at the end of timing or on a second control pulse. W function: Timing after pulse on control contact After energisation, opening of the control contact results in a change in the state of output "R" (or the load) and timing starting. 20 I www.crouzet.com l Panorama Crouzet Control 21

Function diagrams 815E dedicated functions A2 function: Delay on energisation U : Supply R :O utput relay or load T : Timing : Infinity C (Y1) : Command Start : Start timing Reset : Reset to zero TMR48 dedicated functions TMR48 A A function: D elay on A2c function: Delay on energisation AMt function: D elay on energisation AM function: Delay on energisation U : Supply R :O utput relay or load T : Timing : Infinity C (Y1) : Command energisation Ac function: T iming after closing and opening of control contact TMR48 U A function: O n-delay Timers B function: Timing on impulse (one shot) Latching during the time delay Latching during the time delay B function: Timing on impulse (one shot) B function with latching: Timing on impulse (one shot) A1 function: D elay on energisation Bw function: Pulse output (adjustable) C function: Timing after impulse D function: Flip-flop Di function with latching: Flip-flop C function with latching: T iming after impulse Di function: Flip-flop A2 function: D elay on energisation D-Di function: Symmetrical flashing D pause function: Flip-flop H1 function: T iming on energisation H function: Timing on energisation C function: Off-delay G function: Cyclical function H function with latching: T iming on energisation H2 function: T iming on energisation L/LiG/Gi function: Cyclical flashing timers T function: Timing on energisation T function with latching: T iming on energisation W function: O ff-delay 22 W function with latching: Off-delay timer I www.crouzet.com Q1 function: Star-delta "starting" Q2 function: " Star-delta 2" starting W function: Off-delay l Panorama Crouzet Control 23

Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS 18001. Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the www.crouzet.com website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Control relays Instinctive control 24 I www.crouzet.com www.crouzet.com 25

The basics A control relay How can it be defined in simple terms? The control relay is an electronic device which can be used to detect and monitor physical values or electrical values. If a device is found to be operating abnormally, the control relay trips to halt its operation. Crouzet Control, control relays C-Lynx modular housing and E, F, L industrial housing A control relay To execute which actions? Operating mode Sensitivity Control relays Protecting, Monitoring The control relay is used to protect machines by monitoring values such as current, voltage, phase presence and sequence, levels, etc. The control relay ensures total availability of equipment, a major challenge for industries keen to improve their productivity and operating profits. Protection Monitoring Operating mode Threshold Hysteresis Timing Relay output LED Power supply LED Threshold It is one of the indispensable monitoring components for ensuring continuity of service of each installation. Sensing, Alerting Sensing Power supply LED Relay output LED Timing If a fault is detected, the machine is not allowed to run and the user is informed of the anomaly by a visual signal. Thus alerted, the user can then correct any malfunctions. This avoids expensive breakdowns, synonymous with production delays and loss of profitability. Controlling, Triggering In level control, the control relay takes on a different role: it controls the pump in order to manage the level of water in a container (tank, swimming pool, sink, etc). Directly interfacing with probes, it triggers a signal and thus safeguards against machine breakdowns due to threshold adjustment. Alerting Controlling Triggering In addition to this catalog, the www.crouzet.com website offers technical data sheets and installation manuals for each product, available as free downloads. MUS (C-Lynx) ENRM (E, F, L) Crouzet Control, control relays Their features: Positive logic output to protect installations in the event of a power failure. True RMS guaranteed regardless of interference on the electrical supply. Better integration in industrial and commercial cabinets thanks to modular casings and industrial casings. Simplified installation thanks to a power supply for single-phase products and a self-powered version for three-phase products. The combination of a number of control functions in one unit optimises wiring time and simplifies installation. A range of power supplies from 24 to 240 V in one unit for optimised stocks. 26 I www.crouzet.com l Panorama Crouzet Control 27

Applications Crouzet Control, control relays Where are they found? In electrical cabinets associated with other automation functions for the following markets: Food industry Industrial automation systems Quarries Building equipment Water treatment Transport Generating set Frequency control in generating sets or detection of backup units. C-Lynx control relay (underfrequency/ overfrequency) HHZ Fountains Maintaining an adequate water level for the pumps or water jet to work properly, preventing no-load operation (which often irreparably damages the pumps, and always stops the water jet effect). Control relay HNM Control relays Lift Ice maker Motors Crushers Monitoring the internal temperature of the PTC probe. For lift machine rooms, monitoring the temperature between 4 and 40 C according to standard EN81. Fluid management: cold management compressor current control. Control of mains voltage (prevents overheating, destruction of insulation and change of direction). Motor protection, detection of anomalies (temperature too high, motor stopping). Detection of obstruction or jamming. C-Lynx thermocontrol relays for lifts HWT81 Current control relay MUS Motor temperature control relay HWTM Current control relay HIH Cranes Pump management Escalators Steam systems Monitoring overcurrent in the event of motor overload. When too high an overload occurs, the current exceeds the fixed threshold and the relay contact closes. Protecting the pump: detection of no-load operation by undercurrent control, detection of jamming by overcurrent control. Control/detection of phase sequence and failure on motors. Level control (maintaining a constant level). Current control relay MIC Current control relay HIH Phase control relay HWUA Level control relays ENRM 28 I www.crouzet.com l Panorama Crouzet Control 29

Selection guide C-Lynx modular housing, Control relays Phase control (3-phase supply) Phase failure Regeneration Sequence / Asymmetry Overvoltage / Undervoltage Timing Output(s) Casing width (mm) Meas. range (Self-powered) Part number Type With 70 % regeneration Without regeneration Yes / No No / No No 84 873 022 MWG No / -20 % C -2 % 84 873 023 MWU Yes / 5 C 15 % No / No 0.1 C 10 s 1 x 5 A changeover 17.5 208 C 480 V a - 50 / 60 Hz 84 873 024 MWA Window +2 C +20 % -20 C -2 % 84 873 025 MWUA Yes / No No / No No 1 x 5 A changeover 84 873 020 MWS 208 C 480 V a - 50 / 60 Hz 1 x 5 A changeover 84 903 020 EMWS 17.5 2 x 5 A changeover 208 C 440 V a - 50 / 60 Hz 84 873 021 MWS2 No / No 0.3 C 30 s 1 x 5 A changeover 208 C 480 V a - 50 / 60 Hz 84 873 222 M3US Yes / 5 C 15% +2 C +20% / -20 C -2 % 0.1 C 10 s 84 873 026 HWUA 2 x 5 A changeover 35 220 C 480 V a - 50 / 60 Hz No / No 0.3 C 30 s 84 873 220 H3US Loss of phase and neutral Regeneration Sequence / Asymmetry Overvoltage / Undervoltage Timing Output relay Casing width (mm) Meas. range (Self-powered) Part number Type Control relays Without regeneration No / No +2 C +20 % / -20 C -2 % 0.3 C 30 s 2 x 5 A changeover 35 120 C 277 V a - 50 / 60 Hz 84 873 221 H3USN Motor temperature control and phase sequence and failure Sensor Test Latching Supply voltage Output relay Casing width (mm) Supply Part number Type PTC No No 84 873 027 HWTM 24 C 240 V z 2 x 5 A NO 35 208 C 480 V a Reset on front panel Yes 84 873 028 HWTM2 Single-phase DC voltage control with selectable latching Measurement range Functions Hysteresis Timing Output relay Casing width (mm) Supply Part number Type 9 C 15 V c 84 872 140 MUS 20 C 80 V z Over / Undervoltage 5 % C 20 % 0.1 C 10 s 1 x 5 A changeover 17.5 Monitors its own supply voltage 84 872 141 MUS 65 C 260 V z 84 872 142 MUS 0.2 C 60 V z 84 872 120 HUL Over or Undervoltage 5 % C 50 % 0.1 C 3 s 2 x 5 A changeover 35 24 C 240 V z 15 C 600 V z 84 872 130 HUH 20 C 80 V z Monitors its own 84 872 151 MUSF Window 3% fixed 0.1 C 10 s 1 x 5 A changeover 17.5 65 C 260 V z supply voltage 84 872 152 MUSF Current control (over or undercurrent) Measurement range Built-in CT Hysteresis Latching / Timing Output relay Casing width (mm) Supply Part number Type 2 C 20 A a Yes 15% fixed No / No 1 x 5 A changeover 17.5 84 871 122 MIC 2 C 500 ma z 24 C 240 V z 84 871 120 HIL 0.1 C 10 A z No 5 % C 50 % Yes / 0.1 C 3 s 2 x 5 A changeover 35 84 871 130 HIH The control relay accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com 30 I www.crouzet.com l Panorama Crouzet Control 31

Selection guide Frequency control with window Measurement range Selectable latching Hysteresis Timing Output relay Casing width (mm) Supply Part number Type 40 C 70 Hz Yes 0.3 Hz fixed 0.1 C 10 s 2 x 5 A changeover 35 120 C 277 V a 84 872 501 HHZ Level control Probe Emptying / Filling Level / Measurement range Timing Output relay Casing width (mm) Supply Part number Type Resistive 1 or 2 / 250 C 1 MΩ 2 x 5 A changeover 84 870 700 HNM Yes / Yes 35 Digital or PNP / NPN 1 or 2 / None 0.1 C 5 s 24 C 240 V z 84 870 710 HNE 1 x 5 A changeover Digital No / Yes 1 / None 17.5 84 870 720 MNS Over/underspeed control Sensor Measurement range Hysteresis Timing Output relay Casing width (mm) Supply Part number Type 3-wire NPN/PNP sensor, 0 C 30 V, NAMUR Volt-free contact 0.05 s C 10 min 5 % fixed 0.6 C 60 s 1 x 5 A changeover 35 24 C 240 V z 84 874 320 HSV Control relays Temperature control with window (lifts) according to EN81 Sensor Built-in phase control Measurement range Timing Output relay Casing width (mm) Supply Part number Type 3-wire Pt100 1 x 5 A changeover 84 874 110 HT81 Low threshold -1 C +11 C 3-wire Pt100 No High threshold +34 C +46 C 0.1 C 10 s 2 x 5 A NO 35 24 C 240 V z 84 874 120 HT81-2 3-wire Pt100 Yes 480 V 2 x 5 A NO 84 874 130 HWT81 Industrial housing E, F, L, Control relays Phase sequence or phase failure control Regeneration Sequence / Asymmetry Overvoltage / Undervoltage Timing Output relay Casing width (mm) Meas. range (Self-powered) Part number Type 1 x 8 A changeover 200 C 500 V a 84 892 299 EWS None Yes / No No / No No 22.5 2 x 8 A changeover 200 C 460 V a 84 873 004 EWS2 Voltage control with selectable latching Measurement range Functions Hysteresis Timing Output relay Casing width (mm) Supply Part number Type 24 V c 84 872 020 EUL 0.2 C 60 V z Over / Undervoltage 5 % C 50 % 0.1 C 3 s 1 x 8 A changeover 22.5 24 V a 84 872 021 EUL 120 V a 84 872 023 EUL 230 V a 84 872 024 EUL 24 V c 84 872 030 EUH 15 C 600 V z Over / Undervoltage 5 % C 50 % 0.1 C 3 s 1 x 8 A changeover 22.5 24 V a 84 872 031 EUH 120 V a 84 872 033 EUH 230 V a 84 872 034 EUH The control relay accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com 32 I www.crouzet.com l Panorama Crouzet Control 33

Selection guide Current control (over / undercurrent) Level control Measurement range With CT Hysteresis Latching / Timing Output relay Casing width (mm) Supply Part number Type 2 C 500 ma No 5 % C 50 % Yes / 0.1 C 3 s 1 x 8 A changeover 22.5 0.1 C 10 A No 5 % C 50 % Yes / 0.1 C 3 s 1 x 8 A changeover 22.5 10 C 100 A 26 852 304 5 % C 50 % Yes / 0.1 C 3 s 1 x 8 A changeover 22.5 Probe Emptying / Filling Level / Measurement range Timing Output relay Casing width (mm) Supply Part number Type Resistive Yes / Yes 1 or 2 / 5 C 100 KΩ No Resistive Yes / Yes 2 / 250 Ω C 1 MΩ 0.1 C 5 s Resistive Yes / Yes 1 or 2 / 5 C 100 KΩ No 1 x 8 A changeover Resistive Resistive Motor temperature control Sensor Test Latching Manual reset Output relay Casing width (mm) Supply Part number Type PTC Combined with monitoring of wells Yes / Yes + Alarm No 2 / 5 C 100 KΩ No 1 x 8 A changeover Yes No 1 x 8 A NO Yes Yes 1 x 8 A changeover 1 x 8 A changeover 22.5 1 x 8 A changeover 22.5 PTC No Yes Yes 2 x 8 A changeover 22.5 39 Plug-in 8-pin base 39 Plug-in 11-pin base 39 Plug-in 11-pin base 22.5 24 V a 84 870 201 ENR 48 V a 84 870 202 ENR 120 V a 84 870 203 ENR 230 V a 84 870 204 ENR 24 C 240 V a 84 870 200* ENR* 24 V a 84 870 211 ENRM 48 V a 84 870 212 ENRM 120 V a 84 870 213 ENRM 230 V a 84 870 214 ENRM 24 C 240 V a 84 870 210* ENRM* 24 V a 84 870 301 LN 120 V a 84 870 303 LN 230 V a 84 870 304 LN 24 V a 84 870 306 LN 120 V a 84 870 308 LN 230 V a 84 870 309 LN 24 V a 84 870 401 L2N 120 V a 84 870 403 L2N 230 V a 84 870 404 L2N 24 V a 84 870 501 FN 48 V a 84 870 502 FN 2 / 5 C 100 KΩ No 2 changeover 45 120 V a 84 870 503 FN 84 870 504 FN 230 V a 2 / 250 Ω C 5 KΩ 84 870 803 FN LS * Available in 2014. The casing of the new range will be different from the ones presented here. Further information can be found on the data sheets available at www.crouzet.com 24 V c 84 871 020 EIL 24 V a 84 871 021 EIL 48 V a 84 871 022 EIL 120 V a 84 871 023 EIL 230 V a 84 871 024 EIL 24 V c 84 871 030 EIH 24 V a 84 871 031 EIH 48 V a 84 871 032 EIH 120 V a 84 871 033 EIH 230 V a 84 871 034 EIH 24 V c 84 871 040 EIT 24 V a 84 871 041 EIT 48 V a 84 871 042 EIT 120 V a 84 871 043 EIT 230 V a 84 871 044 EIT 24 V a 84 874 015 ETM 120 V a 84 874 013 ETM 230 V a 84 874 014 ETM 24 V a 84 874 025 ETM 2 120 V a 84 874 023 ETM 2 230 V a 84 874 024 ETM 2 24 V a 84 874 035 ETM 22 120 V a 84 874 033 ETM 22 230 V a 84 874 034 ETM 22 The control relay accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com Control relays 34 I www.crouzet.com l Panorama Crouzet Control 35

Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS 18001. Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the www.crouzet.com website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Counters and Ratemeters Counting accuracy 36 I www.crouzet.com www.crouzet.com 37

The basics A counter, a ratemeter How can they be defined in simple terms? A counter can be used to count a number of actions or events. It thus participates in production management and preventive maintenance. A ratemeter can be used to display the speed of rotation of a motor in real time. Crouzet Control, counters and ratemeters A digital range and an electromechanical range A counter, a ratemeter To execute which actions? Operating time Power used Up counting, Down counting For up counting or down counting a number of parts, events, a running time, the counter is the ideal solution. There are different types of counter with the following functions: up/down counter, batch counter, ratemeter, chronometer, multi-totalizer, elapsed time counter, impulse counter. Informing, Displaying Up counting Down counting Informing Preset settings Enable Mode Counters and Ratemeters A counter can allow a user to be informed and to display data and quantities easily. The data displayed can be read directly on the front panel. Displaying CTR48 CEM48 Triggering, Actuating A counter can be used to trigger an action or an intervention on a machine. The outputs actuate directly and/or transmit data to the control system. Measuring, Chronometer timing A counter can be used to schedule preventive maintenance. The machine running time is measured and the duration of an action timed with a chronometer. Triggering Actuating Measuring Chronometer timing In addition to this catalogue, the www.crouzet.com website offers technical data sheets and installation manuals for each product, available as free downloads. Crouzet Control, counters and ratemeters Their features: For fast count applications, a high-speed counting frequency: up to 50 khz. A two-colour or backlit LCD dual display for ease of reading. Considerable space saving due to dualfunction electromechanical and electronic ranges. A complete output operating logic to cover complex applications. Easier maintenance thanks to removable connectors (CTR48). An enhanced multifunction electronic range for optimised stocks. 38 I www.crouzet.com l Panorama Crouzet Control 39

Applications Crouzet Control, counters and ratemeters Where are they found? Compressors Counting operating hours and counting the number of starts. Dehumidifiers Counting operating hours, energy consumption. In electrical cabinets associated with other automation functions for the following markets: Industrial automation systems Building equipment Industrial machines Medical ELECTROMECHANICAL hour and impulse counter CMM48 ELECTROMECHANICAL hour and energy counter CEM48 Tachometer systems Speed measurement and control on shrink wrapping machine. Counting quantities Managing quantities - Packaging by unit, batch or series of batches. Assembly line speed Control of conveyor movement speed. Milling machine Combined ratemeter and counter for controlling the position and speed of a router. Counters and Ratemeters Electronic counter CTR24L 2511 Electronic counter CTR48 Ratemeter CTR24L 2511 Electronic ratemeter AND counters CTR24L 2513 Length measurement Position control Lifts UV lamp Calculation of cut length on wood and paper machines. Managing quantities - Calculation of distance of travel. Combined impulse and hour counters - Maintenance. Start counters and operating time counters. Counting and display of operating times. Event management, wear control. Electronic counter CTR48 Electronic counter CTR48 Electronic counter CTR24L 2514 hour counter CTR24 2323 40 I www.crouzet.com l Panorama Crouzet Control 41

Selection guide Electronic counters 24 x 48 multifunction counters without preselection Functions Totalizer or Hour counter or Ratemeter Modes Multiplication coefficient Decimal point Max. counting speed Display Counting capacity Supply Part number Type Dir / up.dn / up.up Yes Yes 50 khz (DIR mode) 999,999 Ph / 2-ph / 4-ph LED Start / Stop No Yes 999,999 hrs 0.001 s C 999,999 hrs sec -1 / min -1 Yes Yes 50 khz 999,999 10 C 30 V c 87 623 570 CTR24L - 2511 Double totalizer Independent inputs (A and B) Totalizer and Ratemeter Independent inputs Counting A / B / A-B / A+B AdivB / %AB Dir / up.dn / up.up Ph / 2-ph / 4-ph sec -1 / min -1 Yes Yes 25 khz LED 999,999 10 C 30 V c 87 623 571 CTR24L - 2512 Yes Yes 30 khz LED 999,999 10 C 30 V c 87 623 572 CTR24L - 2513 Double totalizer Common input Totalizer + Ratemeter or Totalizer + Totalizer or Totalizer + Hour or Hour + Hour Counting (total / partial) Counting + sec -1 / min -1 Counting Counting + Start / Stop Yes Yes 50 khz LED 999,999 10 C 30 V c 87 623 573 CTR24L - 2514 Yes Yes 35 khz 50 khz 999,999 40 khz 999,999 999,999 hrs LED 0.001 s C 999,999 hrs Start / Stop No Yes 999,999 hrs 0.001 s C 999,999 hrs 10 C 30 V c 87 623 574 CTR24L - 2515 Counters and Ratemeters 24 x 48 counters without preselection Functions Inputs / Reset Max. counting speed Display Counting capacity Supply Part number Type PNP / Contact 87 622 161 CTR24-2223 Hour NPN or contact / Contact 99,999.99 hrs LCD 0.1 s C 99,999.99 hrs Lithium battery 87 622 162 CTR24-2233 Voltage / Contact 87 622 170 CTR24-2224 PNP / Contact 87 622 181 CTR24-2323 Hour NPN or contact / Contact 99,999.99 hrs Orange (backlit) 0.1 s C 99,999.99 hrs Lithium battery 87 622 182 CTR24-2333 Voltage / Contact 87 622 190 CTR24-2324 PNP / Contact 87 622 061 CTR24-2241 Totalizer NPN or contact / Contact 99,999,999 LCD 99,999,999 Lithium battery 87 622 062 CTR24-2251 Voltage / Contact 87 622 070 CTR24-2242 PNP / Contact 87 622 081 CTR24-2341 Totalizer NPN or contact / Contact 99,999,999 Orange (backlit) 99,999,999 Lithium battery 87 622 082 CTR24-2351 Voltage / Contact 87 622 090 CTR24-2342 The counters and ratemeters accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com 42 I www.crouzet.com l Panorama Crouzet Control 43

Selection guide 48 x 48 multifunction counters with preselection Functions Number of preset(s) Max. counting speed Display Counting capacity Outputs Supply Part number Type Preselection counter Ratemeter Chronometer Multi-totalizer Preselection counter Ratemeter Chronometer Multi-totalizer Batch counter Preselection counter Ratemeter Chronometer Multi-totalizer Preselection counter Ratemeter Chronometer Multi-totalizer Batch counter Preselection counter Chronomètre Electromechanical counters Hour counters 1 2 1 2 1 2 40 KHz 40 KHz 5 KHz Backlit LCD (orange) extra-bright 2 lines Two-colour LCD (red and green) 2 lines Backlit LCD (green) 2 lines -999,999 C 999,999-999,999 C 999,999-999,999 C 999,999 1 x 5 A changeover 1 solid state 1 x 5 A changeover 1 x 5 A NO 2 solid state 1 x 5 A changeover 1 solid state 1 x 5 A changeover 1 x 5 A NO 2 solid state 1 x 3 A changeover 1 x 3 A changeover 1 x 3 A NO 10 C 30 V c 87 621 111 CTR48 24 V a 87 621 112 CTR48 90 C 260 V a 87 621 115 CTR48 10 C 30 V c 87 621 121 CTR48 24 V a 87 621 122 CTR48 90 C 260 V a 87 621 125 CTR48 10 C 30 V c 87 621 211 CTR48 24 V a 87 621 212 CTR48 90 C 260 V a 87 621 215 CTR48 10 C 30 V c 87 621 221 CTR48 24 V a 87 621 222 CTR48 90 C 260 V a 87 621 225 CTR48 11 C 30 V c 87 629 111 CTR48E 115 V a 87 629 113 CTR48E 230 V a 87 629 114 CTR48E 11 C 30 V c 87 629 121 CTR48E 115 V a 87 629 123 CTR48E 230 V a 87 629 124 CTR48E Dimensions (mm) Counting capacity Frequency Supply Part number Type 20 C 30 V a 99 772 710 CHM48 42 C 48 V a 99 772 711 CHM48 50 Hz a 100 C 130 V a 99 772 712 CHM48 360 C 440 V a 99 772 713 CHM48 48 x 48 99,999.99 187 C 264 V a 99 772 714 CHM48 20 C 30 V a 99 772 718 CHM48 42 C 48 V a 99 772 719 CHM48 60 Hz a 100 C 130 V a 99 772 715 CHM48 187 C 264 V a 99 772 716 CHM48 360 C 440 V a 99 772 717 CHM48 10 C 30 V c 99 772 810 CHM48 48 x 48 999,999.99 c 36 C 80 V c 99 772 811 CHM48 100 C 130 V c 99 772 812 CHM48 20 C 30 V a 99 782 710 CHM24 50 Hz a 100 C 130 V a 99 782 712 CHM24 187 C 264 V a 99 782 714 CHM24 99,999.99 24 x 48 20 C 30 V a 99 782 718 CHM24 60 Hz a 100 C 130 V a 99 782 715 CHM24 187 C 264 V a 99 782 716 CHM24 999,999.99 c 10 C 30 V c 99 782 810 CHM24 15 x 32 99,999.99 c 4.5 C 35 V c 99 792 810 CHM15 24 V a 99 793 710 CHMDR Modular 50 Hz a 115 V a 99 793 712 CHMDR Rail Din 99,999.99 35 mm 230 V a 99 793 714 CHMDR c 10 C 27 V c 99 793 810 CHMDR The counters and ratemeters accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com Counters and Ratemeters 44 I www.crouzet.com l Panorama Crouzet Control 45

Selection guide Impulse counters Dimensions (mm) Reset to zero Counting capacity Supply Part number Type 15 x 32 Clip-fixing 24 x 48 Clip-fixing 24 x 48 Clip-fixing 24 x 48 Screw-fixing 24 x 48 Screw-fixing 36 x 37 Screw-fixing 36 x 37 Screw-fixing 36 x 48 Screw-fixing 36 x 48 Screw-fixing No 9,999,999 No 999,999 Yes 99,999 No 999,999 Yes 999,999 No 999,999 Yes 999,999 No 999,999 Yes 999,999 24 V a - 50 / 60 Hz 99 778 710 CIM15 115 V a - 50 / 60 Hz 99 778 712 CIM15 230 V a - 50 / 60 Hz 99 778 714 CIM15 5 V c 99 778 805 CIM15 12 V c 99 778 806 CIM15 24 V c 99 778 810 CIM15 24 V a - 50/60Hz 99 777 710 CIM 24 230 V a - 50/60Hz 99 777 714 CIM 24 12 V c 99 777 815 CIM 24 24 V c 99 777 810 CIM 24 24 V a - 50/60Hz 99 777 720 CIM 24 230 V a - 50/60Hz 99 777 724 CIM 24 12 V c 99 777 825 CIM 24 24 V c 99 777 820 CIM 24 24 V a - 50/60Hz 99 776 904 CIM 24 x 48 115 V a - 50/60Hz 99 776 902 CIM 24 x 48 230 V a - 50/60Hz 99 776 901 CIM 24 x 48 24 V c 99 776 907 CIM 24 x 48 110 V c 99 776 905 CIM 24 x 48 24 V a - 50/60Hz 99 776 924 CIM 24 x 48 115 V a - 50/60Hz 99 776 922 CIM 24 x 48 230 V a - 50/60Hz 99 776 921 CIM 24 x 48 24 V c 99 776 927 CIM 24 x 48 24 V a - 50/60Hz 99 776 604 CIM 36 x 37 115 V a - 50/60Hz 99 776 602 CIM 36 x 37 230 V a - 50/60Hz 99 776 601 CIM 36 x 37 24 V c 99 776 607 CIM 36 x 37 110 V c 99 776 605 CIM 36 x 37 24 V a - 50/60Hz 99 776 613 CIM 36 x 37 115 V a - 50/60Hz 99 776 611 CIM 36 x 37 230 V a - 50/60Hz 99 776 610 CIM 36 x 37 24 V c 99 776 616 CIM 36 x 37 24 V a - 50/60Hz 99 776 704 CIM 36 x 48 115 V a - 50/60Hz 99 776 702 CIM 36 x 48 230 V a - 50/60Hz 99 776 701 CIM 36 x 48 24 V c 99 776 707 CIM 36 x 48 48 V c 99 776 736 CIM 36 x 48 110 V c 99 776 705 CIM 36 x 48 24 V a - 50/60Hz 99 776 713 CIM 36 x 48 115 V a - 50/60Hz 99 776 711 CIM 36 x 48 230 V a - 50/60Hz 99 776 710 CIM 36 x 48 24 V c 99 776 716 CIM 36 x 48 Counters and Ratemeters Dual function 48 x 48 counters Functions Reset to zero Counting capacity Frequency Supply Part number Type Impulse Hour Power Hour No No 9,999,999 99,999.99 hrs 50 Hz a 60 Hz a 20 C 30 V a 99 779 710 CMM48 100 C 130 V a 99 779 712 CMM48 187 C 264 V a 99 779 714 CMM48 20 C 30 V a 99 779 718 CMM48 100 C 130 V a 99 779 715 CMM48 187 C 264 V a 99 779 716 CMM48 9,999,999 / 999,999.99 hrs c 10 C 30 V c 99 779 810 CMM48 9,999,999 99,999.99 kw/hrs 50/60 Hz a 115 V a 99 780 712 CEM48 230 V a 99 780 714 CEM48 The counters and ratemeters accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com 46 I www.crouzet.com l Panorama Crouzet Control 47

Connection diagrams CTR24 counters Connections Hour counters Impulse counters 1. NC 2. Start / Stop input 3. Reset input 4. Enable front panel Reset 5. Mode 1 (Time selection) 6. GND / Optional backlighting - (only 23xx) 7. Mode 2 (Time selection) 8. Optional backlighting + (only 23xx) 1. Fast count 2. Slow count 3. Reset input 4. Enable front panel Reset 5. Counting (counting direction) 6. GND 7. Optional backlighting - (only 23xx) 8. Optional backlighting + (only 23xx) Counters and Ratemeters Types 2223 and 2323: Types 2233 and 2333: Types 2241 and 2341: Types 2251 and 2351: Part numbers: 87 622 161 87 622 181 Part numbers: 87 622 162 87 622 182 Part numbers: 87 622 061 87 622 081 Part numbers: 87 622 062 87 622 082 Types 2224 and 2324: Part numbers: 87 622 170 87 622 190 1. Common z 2. Start / Stop input 3. Reset input Types 2242 and 2342: Part numbers: 87 622 070 87 622 090 1. Fast count 2. Common z 3. Reset input 4. Enable front panel Reset 4. Enable front panel Reset 5. Mode 1 (Time selection) 6. GND / Optional backlighting - (only 23xx) 7. Mode 2 (Time selection) 8. Optional backlighting + (only 23xx) 5. NC 6. GND 7. Optional backlighting - (only 23xx) 8. Optional backlighting + (only 23xx) 48 I www.crouzet.com l Panorama Crouzet Control 49

Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS 18001. Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the www.crouzet.com website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Temperature controllers A degree of constancy 50 I www.crouzet.com www.crouzet.com 51

The basics A temperature controller How can it be defined in simple terms? Crouzet Control, temperature controllers A complete range A temperature controller is an electronic device which is used to monitor and ensure a constant temperature according to a setpoint. A temperature controller To execute which actions? Measuring Measuring The temperature controller is used to measure and maintain the temperature of a room, an enclosure, a liquid. Functions It guarantees a constant temperature and ensures optimum use of the systems in which it is found: ovens, baths, cold rooms, machines. Controlling Programming mode Setpoint settings Controlling, Displaying, Alerting Directly interfacing with probes, the temperature controller controls and displays the temperature of the enclosure. Displaying CTD46 Temperature controllers It can be used to set an alert in the event of an anomaly (low and/or high temperature). Monitoring The temperature controller action is not limited to monitoring. It senses and controls the temperature, acting on the system heating or cooling. If the controlled temperature does not conform to the setpoint, the controller implements a heating or cooling action. Alerting Monitoring In addition to this catalogue, the www.crouzet.com website offers technical data sheets and installation manuals for each product, available as free downloads. Crouzet Control, temperature controllers Their features: Adaptive tuning products which manage their parameters independently: PID, temperature rise and inertia curve to simplify the installation. A sophisticated control algorithm to obtain a temperature as close as possible to the setpoint. A dual display makes it user-friendly and easy to use. Compatibility with all types of probe thanks to a "Multi-technology probe input". Multiple outputs (logic and/or relay) for optimum integration in any system. 52 I www.crouzet.com l Panorama Crouzet Control 53

Applications Crouzet Control, temperature controllers Where are they found? Chocolate factory Managing the temperature of the liquid chocolate before it is poured into a mould. Bain-Marie Maintaining the temperature of a bain-marie during cooking. In electrical cabinets associated with other automation functions for the following markets: Industrial automation systems Building equipment Food industry Temperature controller CTD43 Temperature controller CTD46 Packaging Fluid management Oven Cold room Monitoring the heating temperature of the various packages. Maintaining the temperature of a ceramic oven. Managing the temperature of an oven with change of setpoint possible via MODBUS. Maintaining a storage room at freezing temperature. Temperature controller MIC48 Temperature controller CTD43 Temperature controller MIC48 Temperature controller CTD46 Temperature controllers Brewing Cooking Air treatment plant Spray booth Managing cooling of fermentation tanks. Control of industrial ovens. Maintaining forced air at the correct temperature. Temperature control for "paint curing" in the motor vehicle industry. Temperature controller Mic48 Temperature controller CTD46 Temperature controller Mic48 Temperature controller CTD46 54 I www.crouzet.com l Panorama Crouzet Control 55

Selection guide Temperature controllers 48 x 48 digital Functions Type of control Alarm Input Output Display Supply Part number Type Heating or Cooling Heating or Cooling Heating and Cooling Heating and / or Cooling PID with auto-tune and adaptive tune PID with auto-tune and adaptive tune PID with auto-tune and adaptive tune PID with auto-tune and adaptive tune Load break monitoring 1 alarm 1 alarm No 2 alarms 3-wire Pt100 or Thermocouple J, K, L, N 3-wire Pt100 or Thermocouple J, K, L, N 3-wire Pt100 or Thermocouple J, K, L, N 3-wire Pt100 or Thermocouple J, K, R, S,T, L, N or voltage or current 1 x 3 A output 1 x 1 A output 1 voltage logic 1 x 1 A relay 1 x 3 A output 1 x 1 A output 1 voltage logic 1 x 1 A relay 1 x 3 A output 1 x 1 A output 1 voltage logic 1 x 1 A relay 1 x 3 A output 1 x 1 A output 1 voltage logic 1 x 1 A relay 1 line (3 digits) 2 lines (3 digits) 2 lines (3 digits) 2 lines (4 digits) 24 V z 89 421 102 CTD43 100 C 240 V a 89 421 108 CTD43 24 V z 89 421 112 CTD43 100 C 240 V a 89 421 118 CTD43 24 V z 89 422 102 CTD46 100 C 240 V a 89 422 108 CTD46 24 V z 89 422 112 CTD46 100 C 240 V a 89 422 118 CTD46 24 V z 89 422 502 CTH46 100 C 240 V a 89 422 508 CTH46 24 V z 89 422 512 CTH46 100 C 240 V a 89 422 518 CTH46 24 V z 89 422 002 MIC48 100 C 240 V a 89 422 008 MIC48 24 V z 89 422 012 MIC48 100 C 240 V a 89 422 018 MIC48 Temperature controllers Accessories Description Part number Current transformer for MIC 48 (10 A / 50 ma) 26 852 301 Current transformer for MIC 48 (25 A / 50 ma) 26 852 302 Current transformer for MIC 48 (50 A / 50 ma) 26 852 303 Current transformer for MIC 48 (100 A / 50 ma) 26 852 304 Thermocouple probe J with nickel-plated brass eyelet - max: 400 C 79 696 030 Thermocouple probe J with 304 stainless steel casing - max: 600 C 79 696 031 Accessories (continued) Description Part number Thermocouple probe J with 316 stainless steel sheath - diameter 6 mm - max: 400 C 79 696 032 Thermocouple probe J with 316 stainless steel sheath - diameter 5 mm - max: 400 C 79 696 033 Thermocouple probe K with 304 stainless steel casing - max: 1100 C 79 696 034 Pt100 probe Class B with 316 stainless steel sheath - max: 200 C 79 696 035 Pt100 probe Class B with 316 stainless steel sheath - max: 400 C 79 696 036 Pt100 probe Class B with aluminium V6 sheath - max: 200 C 79 696 037 56 I www.crouzet.com l Panorama Crouzet Control 57

Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS 18001. Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. In addition to this catalogue, the www.crouzet.com website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Safety relays User protection 58 I www.crouzet.com www.crouzet.com 59

The basics A safety relay How can it be defined in simple terms? Crouzet Control, safety relays A relevelling range and a machine safety range A safety relay is an automation component which is part of a machine's safety system, thus contributing to the safety of people around it. It is essential for compliance with machine safety standards (EN ISO 13849-1 and IEC/EN 62061). A safety relay To execute which actions? Power supply LED Power supply LED Protecting, Controlling The safety relay protects people. It controls a user's action to ensure that this does not lead to anything that may damage his health, either voluntarily or accidentally. Protecting Controlling Relay output LED Relay output LED Error indication LED Monitoring, Sensing When a machine may be dangerous for the user, it is necessary to monitor all hazardous operations, and detect the slightest anomaly. Monitoring KNA3-YS KSW3-JS Actuating It is then necessary to actuate safety contacts to stop cutting, rotating, burning items, etc which could be hazardous for the user. Sensing Actuating Crouzet Control, safety relays Their features: Safety relays In addition to this catalogue, technical data sheets for each product are available as free downloads on the www.crouzet.com website. A range covering machine applications: emergency stop and mobile guard monitoring, emergency stop with timed contact, two-hand control, zero speed monitoring, expansion module and power supply accessory. A relevelling control relay for the lift market. A safety component with one or two channels. Prohibition of machine starting if a problem becomes apparent through self-checking of the integrity of the control devices. A range conforming to: - Performance Level (PL) e and category 4 according to EN ISO 13849-1 - Limit value SIL 3 (SIL CL) according to IEC/EN 62061 60 I www.crouzet.com l Panorama Crouzet Control 61

Selection guide Crouzet Control, safety relays, How to choose? Machine safety Function(s) Safety category Safety contacts Data contact Connection Casing width (mm) Supply Part number Type 24 V c 85 102 031 Emergency stop & Safety guard monitoring with 1 channel 3 3 x NO 1 x NC Screw terminals Removable spring terminals 22.5 110 V a 85 102 034 230 V a 85 102 035 24 V c 85 103 031 110 V a 85 103 034 KNA3-YS KNAC3-YS 230 V a 85 103 035 24 V z 85 102 436 Emergency stop & Safety guard monitoring with 2 channels 4 3 x NO 1 x NC Screw terminals 22.5 110-115 V a 85 102 434 230 V a 85 102 435 KNE3-YS Removable spring terminals 24 V z 85 103 436 KNEC3-YS Timed contacts 1 C 10 s 4 2 x NO (instantaneous) 1 x NO (timed) - Screw terminals 22.5 24 V z 85 102 736 KZR3-YS Expansion module for safety relays 4 (combined with a level 4 safety relay) 5 x NO 1 x NC (feedback loop) Screw terminals 22.5 24 V z 85 102 956 110-115 V a 85 102 954 230-240 V a 85 102 955 KZE5-YS Zero speed monitoring 4 3 x NO 1 x NC 1 x NO 2 x solid state outputs Screw terminals 45 24 V c 85 102 331 KSW3-JS Safety relays 2 x NO - 24 V c 85 102 621 KZH2-Y2 Two-hand control 4 3 x NO 1 x NC Screw terminals 22.5 24 V c 85 102 631 24 V a 85 102 632 KZH3-YS Power supply for 24 V c safety relays - - - Screw terminals 22.5 85 C 265 V z 85 102 208 KPS0-YS Relevelling control according to EN 81-1, -2 (lift standard) Function(s) Safety category Safety contacts Data contact Connection Casing width (mm) Supply Part number Type Relevelling zone control for lifts 4 2 x NO - 24 V z 85 102 826 KZHNU-YS Removable screw terminals 22.5 1 x NC 24 V z 85 102 526 KZHNV-YS 62 I www.crouzet.com l Panorama Crouzet Control 63

Applications Crouzet Control, safety relays Where are they found? Emergency stop and guard monitoring Emergency stop modules with 1 or 2 channels KNA3-YS and KNE3-YS, KNAC3-YS and KNEC3-YS SAFETY RELAYS Relevelling lift cars Levelling the landing and the lift car KZHNU-YS and KZHNV-YS SAFETY RELAYS Crouzet Control Behind every project, technologies and expertise Local support for all industrial projects. A multi-skilled team. A sales presence in over 40 countries. A Premium offer designed to ensure the excellence of products and services. Eco-design integrated in Crouzet's "Offer Creation Process". Certifications: ISO 9001, ISO 14001, OHSAS 18001. Products which comply with international standards (UL, CSA, EC). A dynamic R&D department. They can be found in electrical cabinets, associated with other automation functions in the following markets: Building equipment Industrial automation systems In addition to this catalogue, the www.crouzet.com website offers the latest tools, available as free downloads, including technical data sheets and installation manuals for each product. Zero speed monitoring Sensorless control for stopping electric motors Two-hand control Control of two-hand control console Safety relays Single or three-phase KSW3-JS SAFETY RELAYS KZH2-YS and KZH3-YS SAFETY RELAYS 64 I www.crouzet.com l Panorama Crouzet Control 65

Notes Logic controllers Concentrated performance Smart & Essential 66 I www.crouzet.com www.crouzet.com 67

The basics Millenium 3 A logic controller How can it be defined in simple terms? Crouzet Automation Logic Controllers Millenium 3, concentrated performance The Millenium 3 Smart logic controller is a programmable logic controller which enables the control and monitoring of machines or automation installations with up to 50 I/O. A logic controller is a programmable module which is used to control small automation systems or small installations. It is an electronic device which combines all of Crouzet's historic expertise. The logic controller is a plural solution in a control system since it contains solutions that can replace a number of products: timers, counters, control relays, temperature controllers, impulse relays, etc. The logic controller operates as the brain of applications. It is capable of retrieving information and triggering actions; it can be adapted to suit the needs of customer applications. Timers + + + + more Control relays Counters Temperature controllers A logic controller To execute which actions? Power supply terminals Input terminals Controlling Controlling Blue screen with 4 lines of 18 characters Programming port The logic controller controls and automates a set of actuators according to the state of the sensors, the passing of time and the program created using the M3 Soft software. Measuring, Operator dialogue Measuring 6 programmable buttons Output terminals The logic controller integrates a local screen, a true operator interface, where the user can view the measured values. The buttons on the front panel are configurable and can be used in programs. The M3 Soft software can be used to design an installation easily, test it using simulation mode and communicate with the application with monitoring mode. Managing The logic controller easily performs and manages complex control system sequences, by means of integrated functions. Operator dialogue Managing Calculation of level of liquid in a tank Timers Digital or adaptive tune PID regulation Logic controllers Communicating, Triggering The logic controller can be used to communicate remotely with PCs or mobile phones via SMS across a network. It also incorporates a calendar to ensure the setting and triggering of actions. Communicating Triggering External preset Up/Down counter Sunrise Sunset Time To tackle simpler applications that still require a powerful logic controller, Crouzet Automation offers the Millenium 3 Essential range. The 12 VDC or 24 VDC Millenium 3 Essential range includes a variety of versions and is compatible with a large range of accessories. It is the right solution for simple needs. 68 I www.crouzet.com l Panorama Crouzet Automation 69

The range Accessories Crouzet Automation Logic Controllers The Millenium 3 Smart range Multiple configuration options derived from an extensive product range with numerous accessories Crouzet Automation Logic Controllers Accessories Sensors, power supplies, converters, remote screens and communication accessories offer solutions to control your automation systems with the greatest ease of use. Simplified connectivity making integration of communication systems easy Easy implementation supported by free, user-friendly programming software (M3 Soft) Application-specific solutions thanks to dedicated and easy to use specific function blocks Enhanced visibility on the display with high contrast, blue back lit LCD screen Expandable versions I Sensors Ambient temperature sensor NTC temperature probes Light sensor Ventilation duct temperature sensor Potentiometer I Memory cartridge Accessories I XD26 Compact versions XB26 XD10 XB10 Expandable kit Power supplies I Converters Power supplies from 7.5 to 240 W 5, 12 or 24 V Temperature and current/voltage converters Programmable touchpanels STN and GSM modems Bluetooth interface Communication solutions Logic controllers I CD20 CB20 CD12 CB12 Compact kit I Remote screens 70 I www.crouzet.com l Panorama Crouzet Automation 71

Communication solutions Crouzet Automation Logic Controllers Extensive Connectivity Options Solutions with close proximity to your installation Wide Area Network (WAN) solutions Millenium 3 Virtual Display - Bluetooth or USB M3MOD - GSM modem communication interface Your requirements Our solution Main functions Your requirements Our solution Main functions Viewing setpoints on a panel less than 10 m away Changing and modifying setpoints Locating the Millenium 3 display unit remotely Reading counters in the vicinity Remote viewing of the Millenium 3 display unit - on an Android smartphone via Bluetooth - on a PC via Bluetooth or USB Display/modification of program setpoints Access to a virtual panel (Millenium 3 without display unit) In summary Bluetooth interface (10 m): Millenium 3 accessory Two versions: Lite (ESC/ENTER buttons disabled) & Standard Receiving remote early warning of an event Consulting a value or an internal state Occasionally modifying setpoints GSM Automatic notification of alarms via SMS Input and output states, as well as all program values, can be polled and controlled remotely Reports can be produced using the available variables Management of telephone contacts In summary Reliable plug & play solution that is simple to install Solution managed using M3 Soft software Option to send SMS messages via a telecom operator service MTP programmable touch panels - RS232 cable Remote management solutions with (2) - Cloud Your requirements Displaying data on a graphic panel Modifying setpoints from the touch panel Taking control of the remote panel from a distance Our solution Option VNC link (1) Main functions Supervision of your installation Use of Millenium 3 internal data, processing alarms and recipes Display of text, data, graphics, animations Archiving of data Customization of interfaces (picture library) Remote control of panel In summary Storage: 128 MB flash memory, SD card and USB key Direct communication using the Millenium 3 programming port Programmable with EB software (compatible with Windows 2000/XP/Vista/7) Extensive connectivity Your requirements Supervising and monitoring installations with up to 50 remote I/O Managing an installed base of machines Accessing your data remotely, 24/7 Optimizing your maintenance operations Our solution Millenium 3 Netbiter EC220 GPRS Millenium 3 Netbiter EC150 Internet Modbus Internet (via router or ADSL box) Main functions Remote control of an automated application Display of Millenium 3 program parameters and values via the internet Remote setpoint modification Data logging Management of events sent via emails or SMS In summary Direct communication between Netbiter and Millenium 3 via the SLin/SLout protocol or via Modbus GPRS: SIM card procured via HMS Cloud solution: secure remote server Easy to set up and use Several Millenium 3 can be connected via Modbus Local Area Network (LAN) solutions (1) VNC: Virtual Network Computing. Allows a device to be controlled remotely. (2) Partnership solutions with the HMS company, validated by Crouzet Automation and HMS. Information relating to the products has been provided by the supplier of each product respectively, and they are wholly responsible for its accuracy in addition to supplying and providing backup for their products. Programmable touch panels and communication extensions Modbus networks Your requirements Managing a group of machines or an installation on a local area network Centralizing data Displaying data on a graphic panel Modifying setpoints from the panel Accessing the system locally in real time Our solution Modbus Main functions See MTP programmable touch panels solution Management and centralizing of data in a single place Display of Millenium 3 program values Remote setpoint modification In summary MTP panel Modbus master XN05 extension: Modbus Ethernet TCP/IP XN06 extension: Modbus RS485 RTU Communication extensions - Modbus RS485 or Modbus Ethernet TCP/IP Your requirements Managing a group of machines or an installation on a local area network Centralizing data Accessing the system locally in real time Our solution Modbus Main functions Can be combined with distributed automation Management and centralizing of data in a single place Display of Millenium 3 program values Remote setpoint modification In summary Uses Modbus protocol XN05 extension: Modbus Ethernet TCP/IP XN06 extension: Modbus RS485 RTU Compatible with standard supervisors Logic controllers 72 I www.crouzet.com l Panorama Crouzet Automation 73

M3 Soft software Crouzet Automation Logic Controllers Millenium 3 and M3 Soft The M3 Soft is a high-performance software platform used to program the Millenium 3 logic controller and optimize design times. Free The Millenium 3 programming software (M3 Soft) can be downloaded free of charge from the Crouzet website at www.crouzet.com M3 Soft software Its features Simple Quick, simple and intuitive programming requires no specialist knowledge Self-teaching made easier thanks to a user-friendly online help guide and programming examples A simulation mode that consistently represents controller operation Powerful A complete range of basic functions: counting, timing, comparison, display, logic, gain, sin/cos, etc are also available A wide range of dedicated functions: pump rotation, PID regulation, movement, pressure, level, water ratio, solar tracking, and flow User-friendly and ergonomic Software available in 5 languages: English, French, Italian, German and Spanish Function block programming is fun and very visual Blocks simply organized by function for quick access Help associated with each function block accessible at the click of a button Programming langages: FBD (Function Bloc Diagram) and SFC (Sequential Function Chart/ Grafcet) or LD (Ladder Diagram) User-definable and effective Logic controllers Possibility of creating and saving custom macros in the macro tab allowing the user to simplify programs and utilize their expertise Blocks can be wired in wiring mode or text mode Move one or more blocks without disconnecting the wires Choice of programming language Possibility of protecting macros by locking them with a password for greater security Clear work area Customized password protection 74 I www.crouzet.com l Panorama Crouzet Automation 75

Function blocks APPLICATION INPUTS/OUTPUTS CALCUL CONTROL Cam Bloc Control of a group of 8 integral cam wheels. Gain Conversion of an analog value by changing the scale and offset. Discrete Input Integer Input Timer Large set of timer functions (A/C, BW, B/H,Li/L, Totalizer) Angular Cam Timer Cam timer with the angle made by the cams as the command input. Add/Subb Simple operations on integers: Addition and/or Subtraction. Filtered Digital Input Discrete Output Schmitt Trigger Monitoring of an analog value in relation to two thresholds. Pumps management Pumps Management (Tank Management with circular pump changeover). Mul/Div Simple operations on integers: Multiplication and/or Division. Analog Input 0..10V PWM Output Timer A Delay of actions for a predefined time. Sunrise Sunset Time Calculation of the sunrise and sunset time in relation to the latitude and longitude. ADD/SUB 2 Inputs The ADD-SUB (Addition or Subtraction) function is used to perform simple operations on integers. Filtered Analog Input Analog Output Expansions 10 bits Bistable Impulse relay function. Solar Tracking one Axis Calculation of the sun's position so that a sun dial can be placed. Sin/Cos Calculation of the cos and sin of an angle between 0 and 90. Analog Input Expansion 10 bits Integer Output Set Reset Bistable memory - Priority assigned to either SET or RESET. Analog PID Regulation (8 bits) Temperature control (pressure or other) with 8 bitsanalog output. Square Root Calculation of the square root of the number present as an input with accuracy to two decimal points. Analog Input Expansion 12 bits Timer Set Reset Trigger of operation of a particular device at a fixed time for a period set by the user. PWM PID Regulation (8 bits) Temperature control (pressure or other) with 8 bitsdigital output. Bit Multiplexer Copy of the selected A or B input to the outputs Q and/q. One Second Clock The blinking input function is active every second. Pressure Gain Interface between a Pressure Sensor and the Millenium 3 logic controller. Multiplexer A B Multiplexing function on 2 analog values. Compare in Zone Comparison of a value between two setpoints (the MIN and MAX values determine the zone). Flow Calculation of the flow of a liquid in a pipe using a differential pressure element or by measuring the dynamic pressure. Demultiplexer Demultiplexing of integers. Used to direct the value of the input to one of the 4 outputs. Display B Button Compare Comparison of two analog values using the =, >, <, >=, <=, =/= operators. Level Calculation of the level of a liquid with or without constant density, in an open or closed tank, using pressure sensors. Multiplexer Multiplexing word inputs. Used to direct the value of one of the selected inputs to a predefined output. Text ESC Button MULTI COMPARE Activation of the output corresponding to the value present on the "Value" input. CTN 1 Temperature measurement It is dedicated to CTN1 (-25 to +85 C). Dec/Bin Break down of an integer type input (16 bits) into 16 bit type outputs. Menu Scroll Minus Button HL Switch Comparison of a value against 5 thresholds. CTN 2 Temperature measurement. It is designed for CTN2 type CTNs (-35 C to +120 C). Bin/Dec LCD Backlight Output Plus Button Make up of an integer type output (16 bits) from 16 bit type inputs. Min Max Saving of the minimum and maximum values of a variable signal. CTN 3 Temperature measurement. It is designed for CTN3 type CTNs (0 C to +200 C). SPLIT 16 bits to 4 Split of a 16-bit word into four 16-bit words with values between 0 and 15. A Button OK Button Reduced Average Update of the configured average of a number of values by deleting the minimum and maximum values. LUX-I Light measurement It is designed for photoresistors and internal light meters. SPLIT 16 bits to 2 Split of a 16-bit word into two 16-bit words with values between 0 and 255. Time Prog Daily, weekly, monthly and yearly time programmer. Twilight Calculation of the sunrise and sunset times and also the twilight times in relation to the latitude and longitude read on the function block inputs. Word Shift Register Shifting of the 16-bit words on each rising edge of the clock. Weekly Time Prog Daily, weekly, monthly and yearly time programmer. Solar Tracking Dual Axis Calculation of the sun's position so that a sun dial can be placed. This positioning depends on the two angles calculated by the function: the elevation angle and the azimuth angle. Shift Register Shifting of information by saving it to the memory (shifting of bits in a 16-bit word on each rising edge of the clock). Preset Counter Preset up/down counter Filtration time information in relation to the water Transfer Function Table of correspondence between the X input and the Y output.the table of correspondence is created from a csv file Up Down Counter External preset up/down counter. Transfer Function 50 values Table of correspondence between the X input and the Y output.the table of correspondence (50 rows max) is created from a sv file Preset H Meter Preset hour counter (preselection of hour, minute). Timer Transfer Function Correspondence table for the Minutes operating time and the Y output. High speed count Counting of the pulses arriving at the inputs of a controller powered by a DC supply at rates in excess of one pulse every 6 ms. Timer Transfer Function 50 values Correspondence table for the Minutes operating time and the Y output. (50 Values) Fast count Counting of the pulses arriving at the input at rates in excess of one pulse every 10 ms. Swimming Pool Filtration temperature. Defrost Defrost cycle management Heat Curve Modulation of the heating water temperature according to the atmospheric conditions. The function uses automatic regulation depending on the temperature outdoors called the temperature curve or "water ratio". Analog PID Regulator (Auto-tuning) Auto-tuning proportional-integral-derivative (PID) controller. PROG XA HMI COMMUNICATION c SL In Writing via serial link of data stored in the controller s fixed addresses SL_In S (saved) Data transmission via a programming port to memory space in the controller s fixed addresses. Data is protected in the event of disconnection of the controller SL Out Reading via programming port of data stored in the controller s fixed addresses. Alarm Control of 10 alarm levels and distribution of a serial data to a digital output, connected to a modem digital input. For example to send a SMS. Message distribution of alarm messages to mobile phones, to the Millenium 3 Alarm tool or to e-mail addresses via the M3MOD GRAFCET SFC PROG Resettable Initial Step When RESET function is activated, activation of the STEP OUTPUT for the function, which is the initial step, and reinitialization of all of the ther active steps. LOGIC Constant On Constant On Hour Minute Indication of the time from the controller (hour and minutes). Initial Step Initial step of an SFC chart Not Or 6 Inputs Constant Off Constant Off Hr Mn Converter Conversion of a time period in the "hour : minute" format to minutes and vice versa. Step A step of an SFC chart. And 2 Inputs Nand 4 Inputs Yes Bit Copy of the input to the output. (very helpful when macros are being used) Controller Status Access to the controller states and modify the behaviour of its FBD and/or SFC program depending on these states. Or Divergence Step Transition of one step to be simultaneously made toward one or two steps. And 4 Inputs Nor 4 Inputs Numerical Constant Integer with a value between -32768 and +32767. Summertime Active function throughout summer time, and inactive throughout winter time. Or Convergence Transition of one to four step(s) to be simultaneously made toward one step. And 6 Inputs Xor 2 Inputs Yes Num Copy of the input to the output. (very helpful when macros are being used) And Divergence Transition of one or two steps to be simultaneously made toward two steps. Or 2 Inputs Boolean 6 Inputs/2 Outputs Memory Saving of a value between -32768 and 32767. And Convergence Step Transition of two steps to be simultaneously made toward one step. Or 4 Inputs Boolean Wait SFC Step Set up of a wait phase or step for a PLC or a device. Move SFC Step Set up of a move step for a motor controlled by the PLC to a position specified on the TARGET input. Motor Multiplexer Combination of the motor control signals produced by two linked MOVE SFC steps. macros Display 15 texts Display of 15 texts one after each other with 15 Displays Function Blocs Storage Storage of data values with an average value. Archive Saving of two values simultaneously with the information relating to their time-stamping. Scroll 4 lines Scroll down of a text of four lines on the screen of the Controller Random Generation of a pseudo-random value between the min and max values set by the user. My Macro Possibility to create a personal macro library and to store them in the Macro tab. 76 I www.crouzet.com Logic controllers Function block marked in red: CTN 1 l Panorama Crouzet Automation Available only for the Millenium 3 Smart Range 77

Applications Crouzet Automation Logic Controllers Where are they found? Buidling Equipment Access Control Infrastructure and Energy Fluid management Swimming pools, fountains, spas Managing circulation pumps, monitoring levels, temperature and conductivity of the water Irrigation/Sprinklers Irrigation control based on temperature, humidity, and day/night cycle Opening control for doors Opening control for doors and other associated security devices for restricting access; synchronization between the various doors Automatic barriers Control barriers with automatic detection of vehicles. Function for selecting opening times / days. filtration Filtration duration settings depending on the water temperature PUMP MANAGEMENT Pump rotation function BOOLEAN OR LOGIC Create logic equations between the connected inputs UP/DOWN COUNTER Up/Down counter with external preset Water treatment Reverse osmosis Pump management HVAC Heat pump Air treatment plant Circulation pumps management, supervision of flow pressure and temperature of osmosis processed water Circulation pumps management, supervision of levels and pressure Management of various parameters such as heating, cooling, fluid temperatures, operation, calendar-based function, frost protection mode, alarm management, etc Maintaining forced air at the correct temperature FLOW Calculation of the flow of a liquid in a pipe CTN Temperature measurement (-35 to +120 C) GAIN Conversion of an analog value by changing the scale and datum point LEVEL Calculation of the level of liquid in a tank Building Automation WATER RATIO Water temperature control CLOCK Weekly and yearly time programmer Solar water heating Automation of operation and heating regulation, remote management of the installation NTC1 Temperature measurement REGULATION Analog PID regulation GAIN Conversion of an analog value by changing the scale and datum point Illuminated signs Managing flashing on illuminated signs Industrial OEMs Packing machines Stretch wrapping machines Controlling the motor that unrolls the packing film. Controls cutting of the film after heat sealing and monitors the duration of the motor cycles Packaging Controlling heat sealing times on blister packs, packaging bags, etc Logic controllers TEMPERATURE CONTROL (pressure or other) WEEKLY TIME PROGRAMMER Programming of time slots during which it will be possible to execute actions LUX-I Measurement of the light level TWILIGHT Calculation of the sunrise and sunset times GRAFCET SFC FUNCTIONS For sequential automation systems (Sequential Function Chart) TIMERS (TEMPORISATEURS) A/C function - BW function - B/H function - Li/L function HIGH SPEED COUNT Counting of pulses AND Logical AND with 2 inputs Other typical applications: Medical, Solar, Agricultural Equipment, Transportation, Hoisting, Handling 78 I www.crouzet.com l Panorama Crouzet Automation 79