Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Similar documents
Philips CoralCare FAQ

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

Electronic converter for level transmitters MT03L Instructions manual

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

SquareLED - Aura Bar & Matrix Beam Light 100

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

TVAC20000 User manual

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Process transmitter RMA422

DH551C/DH550C/DL550C Double Sided Display User Manual

MT03A Electronic converter for flow rate transmitters

User Manual Color video door phone

ABB i-bus EIB Universal dimmer 6155 EB for Installation

Installation Guide VL-MV10. Model No.

KRF EMC Filters Installation, Operation and Maintenance Manual

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

LED Backlight for Technics amplifiers

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

Phono Amplifier brinkmann «EDISON» Manual.

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

DMX LED light effect with 4 lenses

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SATRI AMPLIFIER AMP-51R. Owner s Manual

R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual

Cable guide. for. High Performance Controllers and TeleControllers. Cable types and wiring guidelines

LED Array Board.

Gamma instabus. Technical product information

Figure 1: Device components

VK-P10SE WARRANTY REGISTRATION FORM

Operating Manual. Basic Control BC16. two-channel for eco moon

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

Owners SW-LCD 2.0 Manual & Specifications

Documentation VFD clock 8 a clock

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

DMX-LED-DIMMER X9 HR 9x 16 BIT PWM per 10A

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

of of Re:connect M 203 Pioneer Interface Dominating Entertainment. Revox of Switzerland. E 2.03

FD Trinitron Colour Television

Manual. Simrad IS80 Wind Instrument WI80. English

M203 LG. Multiroom Planer V2.00. Introduction. New features from software V2.00

4-in-1 Motor Controller CAN

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions

SWR Programmable Audio Switcher U S E R S M A N U A L

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

LIGHT AIR SWITCH. User Manual and Troubleshooting Guide WIRELESS LIGHTING MODULE ACKNOWLEDGEMENTS SAFETY WARNINGS EQUIPMENT DESCRIPTION

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

P-2 Installing the monitor (continued) Carry out as necessary

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

S6-R READER. Installation and Operating Instructions

Single cable multiswich programmer PC102W

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

NEO-STB-0004 Neo-Flash 300 RGB User Manual

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

4 Wiring Brochure Wiring and installation of specific control

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

COLOUR CHANGING USB LAMP KIT

GV 460 / GV 461 Impulse Splitters for Incremental Encoders with Potential Separation between Input and Outputs

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

DLP200M 2 Relay Module for Heating and Cooling Plants

INSTALLATION & USER GUIDE

SIREC P, PA, L, LA. Manual

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

QLOCKTWO CLASSIC. Instructions for use

How To Build Megavolt s Small Buffered JTAG v1.2

Serial Flash Programmer. S550-SFWv3 FA Mode. Operation Manual. Sunny Giken Inc.

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

CP-830FP Chassis TX-29E50D TX-29E50D/B TX-29PS12D TX-29PS12F TX-29PS12P SPECIFICATIONS. Order No: PCZ C2

Valcom Wired Digital Clock

508 Phono Preamplifier. Boulder Amplifiers, Inc. 255 S. Taylor Ave. Louisville, CO (303) /1/2018 Rev. 1.

Smart Control SC16 3-Channel for matrix

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

AT47SAW Programmable Selective Amplifier

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

MICROMASTER Encoder Module

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

User Manual. Color video door phone CDV-70P PM0770P Printed In Korea /

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Operating instructions Electronic preset counter Type series 717

Transcription:

Owner s Manual multiswitch 1.41 Firmware-Version 1.06 OS- Version 1.02 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of: Juli 19 th 2012 2005-2012 Aqua Computer GmbH & Co. KG - 1 -

Table of Contents 1. Contents of package...3 2. Preface...3 3. Safety precautions...4 4. Connecting external components...5 4.1. Overview...5 4.2. Power connector...5 4.3. USB...5 4.4. aquabus (I2C-Bus)...6 4.5. Jumpers...6 4.6. Power outputs 1/2...6 4.7. LED-outputs...7 4.8. Relay...8 4.9. aquastream...8 5. Configuration...9 Jumper position 1: aquabus-address...9 Jumper position 2: Save configuration...9 Jumper position 3: Deactivate PWM function...9 Jumper position 4: Button function...10 Jumper position 5: USB/aquabus...10 6. Initial operation...11 7. Further details...12 7.1. Changing the front plate...12 8. Technical Data...12-2 - Aqua Computer GmbH & Co. KG 2005-2012

1. Contents of package MULTISWITCH 1x multiswitch (assembled) 1x internal USB-cable (5-pin), length approx. 70 cm Mounting material 1x this manual 2. Preface Dear customer, We congratulate you on the purchase of a multiswitch from Aqua Computer. We are one of the oldest manufacturers in Germany of PC water-cooling systems. Our products are made from materials of the highest quality. We hope you enjoy your new cooling system. Should you have any questions, we would like to ask you to first look at the "FAQ" area and "forum" on our homepage www.aqua-computer.de. If you should not find an answer to your question there, please email to support@aqua-computer.de. Considering the fast technical development, we reserve the right to be able to perform alterations to the products at any time. It therefore is possible that your product does not correspond precisely to the descriptions or especially the illustrations in this manual. Your Aqua Computer Team 2005-2012 Aqua Computer GmbH & Co. KG - 3 -

3. Safety precautions Before we get into the specifics of the system, we would like you to follow these basic precautions which should be obeyed at all times. 1. Read this manual thoroughly and completely 2. Backup your data before working on the hardware 3. The aquaero may only be used completely assembled in a computer case 4. Never touch, connect or separate cables or electronic components while in use 5. Do not turn on your computer unless you are absolutely certain that all cables are securely and correctly connected to the aquaero 6. Maintenance notes: Use only soft, damp cloths to wipe the device. Do not use benzene, paint thinner, detergents, or chemically treated wiped cloths, and do not place vinyl, plastic, or rubber objects on the device to avoid the risk of malfunction or damage to surface of the device 7. The relay-output may be powered at max. 12 V The current must not exceed 1 Ampere 8. All statements in this manual are subject to the fast technological development. Our products are constantly enhanced. Technical changes, misprints and errors are reserved 9. This product is not designed for use in life support appliances, devices, or systems where malfunction of this product can reasonably be expected to result in personal injury. Aqua Computer customers using or selling this product for use in such application do so at their own risk and agree to fully indemnify Aqua Computer GmbH & Co. KG for any damages resulting from such application. 10. Do not rest your weight on or place heavy objects on the device, and do not apply excessive force to the buttons, switches, or connectors to avoid the risk of damage to the device or personal injury. - 4 - Aqua Computer GmbH & Co. KG 2005-2012

4. Connecting external components MULTISWITCH 4.1. Overview The following schematic shows the multitude of connection possibilities of the multiswitch : 4.2. Power connector Attach a vacant power connector of your PSU. Due to the form of the plug the polarity can not be misinterpreted. Do not use force when connecting the plug but double check if the plug is lined-up correctly (i.e. not upside down) Pinassignment: Pin 1: +12 V Pin 2: GND Pin 3: GND Pin 4: +5 V 4.3. USB Connection possibility for an internal USB-connector on the mainboard. Use the included USB-cable and pay close attention to the polarity (colored wires) of the cable. Incorrect use may result in the destruction of the aquaero and/or the mainboard and further components Therefore pay close attention to the pin assignment of the connectors on the mainboard. Please consult the manual of your mainboard for help. Pin assignment: Pin 1: GND black wire Pin 2: GND black wire 2005-2012 Aqua Computer GmbH & Co. KG - 5 -

Pin 3: D+ Pin 4: D- Pin 5: VCC green wire white wire red wire 4.4. aquabus (I 2 C-Bus) 3-pin add-on connector for optional add-on components by aquacomputer. Only use cables specified by aqua-computer (not included in delivery) Pin assignment: 4.5. Jumpers Pin 1: GND Pin 2: SDA Pin 3: SCL The five positions configure the different functions of the multiswitch. Appropriate short-circuit-bridges, so-called Jumpers, are included in the delivery. The individual functions may be derived from chapter 5. Configuration. 4.6. Power outputs 1/2 Screw clamps that allow the connection of up to eight consumer loads to the power outputs of the multiswitch. The outputs supply a maximum of 12 V at a maximal 1 amp per channel. The total load must not be higher than 40 Watts. Incorrect use may result in the destruction of the multiswitch and/or the mainboard and further components Pin assignment:terminal strip 1 contact 1: Terminal strip 1 contact 2: Terminal strip 1 contact 3: Terminal strip 1 contact 4: Terminal strip 1 contact 5: Terminal strip 1 contact 6: Terminal strip 1 contact 7: Terminal strip 1 contact 8: Terminal strip 2 contact 1: Terminal strip 2 contact 2: Terminal strip 2 contact 3: Output 8 +12 V enabled Output 8 GND Output 7 +12 V enabled Output 7 GND Output 6 +12 V enabled Output 6 GND Output 5 +12 V enabled Output 5 GND Output 4 +12 V enabled Output 4 GND Output 3 +12 V enabled - 6 - Aqua Computer GmbH & Co. KG 2005-2012

Terminal strip 2 contact 4: Terminal strip 2 contact 5: Terminal strip 2 contact 6: Terminal strip 2 contact 7: Terminal strip 2 contact 8: MULTISWITCH Output 3 GND Output 2 +12 V enabled Output 2 GND Output 1 +12 V enabled Output 1 GND NOTICE: When disabled the output voltage lies below 0,5 V When connecting inductive loads (e.g. motors), a self-induction recuperation diode (Schottky) and a 100 nf capacitor need to be connected to the consumer to prevent interferences with the multiswitch and other connected devices. In isolated cases further measures may be required. The outputs are not protected against overvoltage or short-circuits When connecting capacitive and inductive loads appropriate precaution measures must be taken. 4.7. LED-outputs Connection possibilities for up to eight LEDs. The LEDs are operated via an into the multiswitch integrated series resistance of 100 Ω with 5 V. Ultra-bright LEDs (I max 20 ma, U 3 V) may be connected without any series resistance directly to the outputs, for LEDs with a low forward voltage the additional series resistance is calculated as follows: Additional series resistance = ((5 V forward voltage) / I max ) 100 Ω Pin assignment: Pin 1: VCC LED 1 Pin 2: GND LED 1 Pin 3: VCC LED 2 Pin 4: GND LED 2 Pin 5: VCC LED 3 Pin 6: GND LED 3 Pin 7: VCC LED 4 Pin 8: GND LED 4 Pin 9: VCC LED 5 Pin 10: GND LED 5 Pin 11: VCC LED 6 Pin 12: GND LED 6 Pin 13: VCC LED 7 Pin 14: GND LED 7 2005-2012 Aqua Computer GmbH & Co. KG - 7 -

Pin 15: VCC LED 8 Pin 16: GND LED 8 All other pins (17-26) must not be short circuited 4.8. Relay Floating output. Freely usable, maximum breaking capacity 4 A at max. 12 V. Pin assignment: Pin 1: Opening contact (NC) Pin 2: Common connector Pin 3: Breaking contact (NO) 4.9. aquastream Connection possibility to the controller of the aquastream. A maximum of two aquastream-controller may be connected. The following chart shows the connection possibilities depending on the hardware revision of the controller: Revision Controller 1 Revision Controller 2 1.0 or higher not possible 1.5 or higher 3.0 or higher - 8 - Aqua Computer GmbH & Co. KG 2005-2012

5. Configuration MULTISWITCH Via the five configurationjumpers (see chapter 4.5. Jumper) you can permanently configure single functions of the multiswitch. For this purpose the included shortcircuit-bridges ( jumper ) are either removed from the contact pins (position open ) or set on the contact pins (position closed ). The individual positions have the following functions: Jumper position 1: aquabus-address This jumper configures the aquabus-adress of the multiswitch when connected as a aquabus-device e.g. to the aquaero. When connected as a USB-device this function is ignored. Jumper open: Address multiswitch 1 Jumper closed: Address multiswitch 2 Jumper position 2: Save configuration When this jumper is set, the current condition of the outputs are saved with each keypress (supprted only in devices with buttons) and automatically loaded after a reset of the system. Additionally a save via the PC-software aquasuite is possible. If this function is deactivated, so is the function in the aquasuite software Jumper open: Saving deactivated Jumper closed: Speichern activated Jumper position 3: Deactivate PWM function This jumper configures the output of PWM signals at the outputs of the multiswitch. In the default setting (jumper open) PWM signals are generated at the outputs which allow for instance LEDs to be controlled in brightness. You must check if all connected devices are able to 2005-2012 Aqua Computer GmbH & Co. KG - 9 -

handle PWM signals before you activate this function. Failure to do so may result in the destruction of the connected devices If the multiswitch is used as an aquabus-device on the aquaero, the PWM function is always deactivated and the jumper setting is ignored. Jumper open: PWM activated Jumper closed: PWM deactivated Jumper position 4: Button function This jumper configures the functions of the buttons on the front of the device (supprted only in devices with buttons). When the jumper is set, the condition (on/off) of the corresponding power output is switched. Additionally the outputs may be switched via the PC-software if the multiswitch is connected via USB (not possible if connected as an aquabus-device). With an open jumper setting the buttons have no direct influence on the outputs of the multiswitch and are only interpreted via the PC-software when connected as an USB-device. If the power outputs of the multiswitch, when connected as an aquabus-device to the aquaero, should be switched, the jumper must be open Jumper open: Interpret buttons only via the PC-software Jumper closed: Buttons switch power outputs directly Jumper position 5: USB/aquabus This jumper configures which interface of the multiswitch is active. Jumper open: USB enabled, aquabus disabled Jumper closed: aquabus enabled, USB disabled - 10 - Aqua Computer GmbH & Co. KG 2005-2012

6. Initial operation MULTISWITCH Depending on the hardware version either install the multiswitch in an available 5 ¼ -bay of your PC-case (version with buttons and LEDs) or in an available place in the interior of your case (version multiswitch LT without buttons and LEDs). Place close attention that the circuit board is securely fixed and has no conductive contact to parts of the PC-case Now configure the functions of the multiswitch as described in chapter 5. Configuration. Make all desired connections to the multiswitch as described in chapter 4. Connecting external components and make sure that no short-circuits are present at the outputs of the multiswitch. The device may now be operated by starting the computer. To conveniently operate the device the aquasuite software can be used. Software and updates may be found in the internet at http://www.aquacomputer.de in the section Support. 2005-2012 Aqua Computer GmbH & Co. KG - 11 -

7. Further details 7.1. Changing the front plate The front plate of the multiswitch (not multiswitch LT version) can be exchanged for different colored plates (not included in delivery). To do this, simply unscrew the four mounting screws in the corners, change the front plate and carefully retighten the screws. 8. Technical Data Dimensions (WxHxD): approx. 148x42x64 mm Current consumption 5V: typ. 5 ma Current consumption 12 V (plus power output): typ. 10/150 ma (LT/non LT) Load capacity per power output: max. 10 W Total load capacity for all outputs: max. 40 W Load capacity of the relay output: max. 12 V, max. 4 A - 12 - Order code 93391 *AC93391* 2005-2012