Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

Similar documents
A new Scintillating Fibre Tracker for LHCb experiment

SciFi A Large Scintillating Fibre Tracker for LHCb

TORCH a large-area detector for high resolution time-of-flight

Production and Development status of MPPC

The Time-of-Flight Detector for the ALICE experiment

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

READOUT ELECTRONICS FOR TPC DETECTOR IN THE MPD/NICA PROJECT

The hybrid photon detectors for the LHCb-RICH counters

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766:

arxiv:hep-ex/ v1 27 Nov 2003

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

Tests of Timing Properties of Silicon Photomultipliers

The Silicon Pixel Detector (SPD) for the ALICE Experiment

Evaluation of ALICE electromagnetic calorimeter jet event trigger performance for LHC-Run2 by simulation

PoS(PhotoDet 2012)018

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

Status of the CUORE Electronics and the LHCb RICH Upgrade photodetector chain

Updates on the Central TOF System for the CLAS12 detector

Sensors for precision timing HEP

Sensors for the CMS High Granularity Calorimeter

Report from the 2015 AHCAL beam test at the SPS. Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

Solid State Photon-Counters

Beam test of the QMB6 calibration board and HBU0 prototype

Liquid Xenon Scintillation Detector with UV-SiPM Readout for MEG Upgrade

An extreme high resolution Timing Counter for the MEG Upgrade

Current status of Hamamatsu Si detectors mainly for High Energy Physics Experiments

The ATLAS Pixel Detector

Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

arxiv: v1 [physics.ins-det] 1 Nov 2015

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

The ATLAS Tile Calorimeter, its performance with pp collisions and its upgrades for high luminosity LHC

A TARGET-based camera for CTA

THE ATLAS Inner Detector [2] is designed for precision

NEW PARTICLE POSITION DETERMINATION MODULES FOR DOUBLE SIDED SILICON STRIP DETECTOR AT DGFRS

Design of a Gaussian Filter for the J-PARC E-14 Collaboration

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

Silicon PhotoMultiplier Kits

R&D on high performance RPC for the ATLAS Phase-II upgrade

Front end electronics for a TPC at future linear colliders

CAEN Tools for Discovery

First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA

A pixel chip for tracking in ALICE and particle identification in LHCb

Status of CMS and preparations for first physics

Realization and Test of the Engineering Prototype of the CALICE Tile Hadron Calorimeter

STUDY OF ANODE SELF-TRIGGER ABILITY OF ME1/1 CMS ENDCAP CATHODE STRIP CHAMBER

Investigation of Avalanche Photodiodes for EM Calorimeter at LHC. LPNHE, Ecole Polytechnique, F Palaiseau, FRANCE. B. Ille, D.

An extreme high resolution Timing Counter for the MEG experiment Upgrade

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

Precision measurements of beam current, position and phase for an e+e- linear collider

FRONT-END AND READ-OUT ELECTRONICS FOR THE NUMEN FPD

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

HAPD and Electronics Updates

Large photocathode 20-inch PMT testing methods for the JUNO experiment

The CALICE test beam programme

Glast beam test at CERN

Study of the performances of the ALICE muon spectrometer

Diamond detectors in the CMS BCM1F

Double Screening Tests of the CMS ECAL Avalanche Photodiodes

A Large-Area Timing RPC

Systematic study of innovative hygroscopic and non-hygroscopic crystals with SiPM array readout

3-D position sensitive CdZnTe gamma-ray spectrometers

with Low Cost and Low Material Budget

arxiv: v1 [physics.ins-det] 15 Jan 2019

Status of the Timing Detector Plastic+SiPM Readout Option

The CMS Detector Status and Prospects

The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications

RTPC 12 Simulation. Jixie Zhang Aug 2014

LHC Beam Instrumentation Further Discussion

The ALICE Inner Tracking System: commissioning and running experience

Status of CMS Silicon Strip Tracker

Perugia 16 June 2009 Flavio Dal Corso INFN-Padova 1

Application of Hamamatsu MPPC to T2K near neutrino detectors

The Alice Silicon Pixel Detector (SPD) Peter Chochula for the Alice Pixel Collaboration

Performance and Radioactivity Measurements of the PMTs for the LUX and LZ Dark Matter Experiments

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

Proposed STAR Time of Flight Readout Electronics and DAQ

UNIVERSITÀ DEGLI STUDI DI MILANO BICOCCA LAUREA MAGISTRALE IN FISICA

New gas detectors for the PRISMA spectrometer focal plane

SciFi A large Scintillating Fibre Tracker for LHCb

Concept and operation of the high resolution gaseous micro-pixel detector Gossip

Electronics procurements

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov

THE WaveDAQ SYSTEM FOR THE MEG II UPGRADE

High ResolutionCross Strip Anodes for Photon Counting detectors

Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode. R.Bellazzini - INFN Pisa. Vienna February

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

li, o p a f th ed lv o v ti, N sca reb g s In tio, F, Z stitu e tests o e O v o d a eters sin u i P r th e d est sezio tefa ectro lity stem l su

CBF500 High resolution Streak camera

The Status of the ATLAS Inner Detector

arxiv: v1 [physics.ins-det] 2 Dec 2008

First LHC Beams in ATLAS. Peter Krieger University of Toronto On behalf of the ATLAS Collaboration

Transcription:

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals M. Ippolitov 1 NRC Kurchatov Institute and NRNU MEPhI Kurchatov sq.1, 123182, Moscow, Russian Federation E-mail: mikhail.ippolitov@cern.ch V. Lebedev, V. Manko, I. Sibiriak NRC Kurchatov Institute Kurchatov sq.1, 123182 Moscow, Russian Federation A. Akindinov ITEP NRC Kurchatov Institute Cheremushkinskaya 25, 117218, Moscow, Russian Federation N. Gorbunov, P. Nomokonov, I. Rufanov, A. Vodopianov, S. Zaporozhets JINR Joliot-Curie 6, 141980 Dubna, Moscow Region, Russian Federation Time resolution improvement of the electromagnetic calorimeter PHOS (CERN/ALICE experiment) is discussed. The existing PHOS detection channel consists of a scintillating crystal of PbWO4 viewed by an avalanche photo diode (APD) HAMAMATSU S8864-55(S8148) which is coupled to a low noise charge sensitive preamplifier. In order to improve the PHOS timing resolution of the detecting channel it is proposed to add one more photodetector - a silicon photo multiplier (SiPM) to the current APD. APD signal is used for energy measurements and SiPM provides timing information. In this study, we have investigated the properties of the detection channel with the additional SiPM MPPC Hamamatsu S12572 with different pixel size. Laboratory tests and beam test results are presented. We discuss energy and time resolutions of detection channels with two very different photodetectors. International Conference on New Photo-detectors PhotoDet2015 6-9 July 2015 Moscow, Troitsk, Russia 1 Speaker Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0). http://pos.sissa.it/

1. Introduction ALICE is a general-purpose heavy-ion experiment designed to study the physics of strongly interacting matter and the quark-gluon plasma in nucleus-nucleus collisions at the LHC [1]. The PHOton Spectrometer (PHOS [2]) is a high resolution electromagnetic spectrometer which detects electromagnetic particles in a limited acceptance domain at central rapidity and provides photon identification as well as neutral mesons identification through the two - photons decay channel. The PHOS is located inside the ALICE magnet at a distance of 4.6 m from the interaction point and covers 60 o in azimuthal angle and η <0.12 in pseudorapidity. The PHOS consists of 4 independent modules. The PHOS module is divided on a warm and a cold volume. The module contains 3584 detection channels that form a 64x56 matrix. All detection channels are placed inside the cold volume at temperature -25 o C stabilized within ±0.1 o C. This arrangement allows to increase the light yield of the crystals by a factor 3 compared to room temperature and to decrease considerably the detection channel s electronics noise. A Front End Electronics Card (FEEC) reads out 2x16 detection channels. The FEEC performs shaping, digitization, generates individual high voltage for each APD and delivers information for the PHOS trigger system. To cover the necessary energy range from 5 MeV to 80 GeV each channel contains a dual gain shaper with peaking time ~2 μs and gains ratio 1/16. It allows to achieve an effective 14 bits resolution with use of 10 bit ADCs. The digitization is done with the ALTRO chip [3] which digitizes the signal profile with 10 MHz frequency. A more detailed description of the PHOS electronics can be found in [4]. The FEEC readout and trigger electronics is placed inside the warm volume at room temperature. 1.2 The PHOS detection channel upgrade The basic part of the PHOS detection channel (see figure 1) is a 2.2x2.2x18 cm 3 PbWO 4 crystal. Each crystal is viewed by a single APD (Hamamatsu S1848/S8664-55) with 5x5 mm 2 sensitive area. The APD is coupled with a low noise Charge Sensitive Preamplifier (CSP) [5]. The noise equivalent of a single detection channel is ~500 e - (RMS at room temperature). The codes obtained during digitization are stored by DAQ and used off-line for the signal shape reconstruction. An amplitude and an arrival time of the signal are determined from the signal shape. This digital processing provides good two gammas invariant mass resolution ~5-6 MeV/C 2 [6]. Nevertheless, it does not allow to have time resolution σ t better than 3-4 ns at deposit energy in single channel ~ 1 GeV [7]. To improve the time resolution of the detecting channel it is proposed to enter additional fast photodetector SiPM (see figure 1) and use conventional start-stop method for time-of-flight (TOF) measurements. Therefore electronics have to contain two channels: current PHOS slow channel with Hamamatsu S1848/S8664-55 APD and CSP only for energy measurement and fast with SiPM with simple electronic schema only for time measurements. Upgrade of the PHOS with goal of improvement of time resolution to value σ t 0.5 ns can be carried out in 2018-2019 during LS2 of LHC or later. Such time resolution is necessary for improvement of neutron and antineutron rejection power of the PHOS. In this paper option of an arrangement of SiPM and APD at one end face of a crystal is considered. Both photodetectors are sealed on one 19 x 19 mm 2 printed-circuit board (PCB). 2

On the PCB the existing CSP for APD and electronic schema for SiPM are located. In this study Hamamatsu S12572 family MPPC with pixel size 25, 50 and 100 µm and sensitive area 3 x 3 mm 2 were used. For the test two types of detection channel electronics for MPPC were designed and produced fast lifier and simple electronics schema based on AD CMP604 comparator [8]. A B Figure 1: From the left PHOS detection channel, from the right front view of photodetectors, situated on the PCB A- current PHOS design, B proposed design of detection channel. 1.3 Beam test results Before beam test all MPPCs were checked in laboratory. To find operating conditions of MPPCs dependencies of gains on voltage and on dark current were measured both at the room temperature and at -20 o C. As example curves for MPPC with 50 µm pixel are shown on figure 2. Figure 2: From the left - gain vs voltage, from the right gain vs dark current for Hamamatsu MPPC S12572-050 C with serial number 4B000347. For beam-test 3x3 prototype with new design of detectors was prepared (see figure 3). Beam tests with beam momentum 1.5 GeV/C were carried out at the T10 secondary beam line of CERN PS in 2014. Set of scintillation counters and gas Cherenkov s counter were used for trigger and electrons identification. Common start signal was delivered with 60 ps resolution. The prototype was cooled down to -25 o C. The detailed description of the experiment is given in [7]. In figure 3 dependence of time resolution on deposited in detector energy for MPPC S12572-100C and electronics on base of AD CMP604 comparator is shown. All results of time resolution measurements are presented in table 1. 3

It has been studied the influence of timing channel on spectrometric channel. For the case with the current detector preamplifier observed a decrease in the signal from the APD. The effect increases with increasing voltage on the MPPC. In the case of electronic comparator of this behavior was not observed. Energy resolution of 3x3 matrix was defined taking into account APD signals. The energy resolution was determined by fitting the histograms of the sum of the amplitudes of all detectors by Gaussian distribution. For comparison 3x3 matrix with current PHOS detectors was also tested. Results of energy resolution are presented in table 2. Figure 3: From the left front view of 3x3 matrix, from the right time resolution of detection channel vs deposited energy. Table 1: Time resolution measured with different MPPC and with and different electronics at 1 GeV deposited energy. -U(V) σ t (ps) -U(V) σ t (ps) -U(V) σ t (ps) -U(V) σ t (ps) 25 µm pixel with 50 µm pixel with 100 µm pixel with 100 µm pixel with comparator 63.0 552 ± 4 62.5 396 ± 24 62.0 651 ± 18 63.0 167 ± 3 63.5 332 ± 10 63.0 267 ± 10 62.4 423 ± 5 63.5 149 ± 1 64.2 240 ± 5 64.0 175 ± 12 63.5 183 ± 2 65.0 218 ± 4 65.0 140 ± 2 67.0 182 ± 3 66.0 113 ± 3 68.0 150 ± 3 Table 2: Relative energy resolution σ(e)/e at 1.5 GeV/c APD only array APD+100 µm+comparator 0.035 ±0.002 0.037 ±0.001 1.4 Conclusions Results of measurements of time and energy resolutions of 3x3 assemblies from the detecting elements based on lead tungstate crystals are presented. It is shown that introduction of the additional channel with the SiPM MPPC S12572(Hamamatsu) allows to improve significantly timing resolution of the PHOS for 1 GeV energy from the existing 3-4 ns to 0.15-0.2 ns without considerable deterioration of energy resolution. We are grateful to the team of the accelerator complex at CERN for the possibility of carrying out the experiments on the PS accelerator beams and for the excellent performance of 4

the accelerator, as well as to our colleagues from the ALICE experiment and the PHOS collaboration for their help in preparing and carrying out the experiments. This work was supported by the Ministry of Education and Science of the Russian Federation, contract no. 14.610.21.0003 of October 20, 2014. References [1] ALICE Collaboration,ALICE: Physics Performance Report Volume I, J.Phys.G: Nucl.Part.Phys. 30 (2004)1517-1763. [2] ALICE Collaboration, Technical Design Report of the Photon Spectrometer (PHOS), CERN/LHCC 99-4,ALICE TDR 2, 5 March 1999. [3] W R.Esteve Bosch et al.,the Altro Chip: A16 Channel A/D Converter and Digital Preprocessor for Gas Detectors, IEEE Trans. on Nucl. Sci., V.50, No.6, December 2003, p.2460-2469. [4] H.Muller et al., Front-end Electronics for PWO based PHOS Calorimeter of ALICE, Nucl.Instrum.Meth.A567(2006)264-267. [5] D.V.Aleksandrov et al., A High Resolution Electromagnetic Calorimeter Based on Lead-Tunstate Crystals, Nucl.Instrum.Meth. A550(2005)169-184. [6] The ALICE Collaboration, Neutral pion production at midrapidity in pp and Pb Pb collisions at snn = 2.76 TeV, Eur. Phys. J. C (2014) 74:3108. [7] D.V.Aleksandrov et al., Improving the Timing Resolution of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals, Instruments and Experimental Techniques, 2014, Vol. 57, No. 3, pp. 233 247. [8] et al., International Conference on New Photo-detectors PhotoDet2015 Web site, https://indico.inr.ru/event/4/session/3/contribution/56/material/poster/0.pdf 5