ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

Similar documents
ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

InSight Pro. Valuable real-time process insight

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Durable and Reliable Design for 24/7 Use. Overview. Narrow Bezel Optimized for Video Walls. 42 Narrow bezel commercial LED display

MAP Optical Power Meter Module (mopm-b1)

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

Industrial Diode Laser (IDL) System IDL Series

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

CARESTREAM DIRECTVIEW Elite CR System

Safety Light Curtain Orion1 Extended

CARESTREAM DIRECTVIEW Elite CR System

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

User Manual OVP Raman

GCxGC Comprehensive Two-Dimensional Gas Chromatography

OPTICAL POWER METER WITH SMART DETECTOR HEAD

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

MILLENNIA. The Benchmark In Diode-Pumped Solid-State Lasers.

OmniStar GX2 Headend Optics Platform GX2 LM1000E Series

ABB EQmatic Energy Analyzer, M-Bus QA/S , 2CDG110226R0011, QA/S , 2CDG110227R0011

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

Datasheet: SimpliFiber Pro

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Standard Operating Procedure of nanoir2-s

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

Agilent 87075C Multiport Test Set Product Overview

General Specifications

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

USA Price List. January or 8-channel LIBSCAN system (100 mj, 1064 nm laser) Alternative LIBSCAN configurations

Product Guide. WaveAnalyzer High-Resolution Optical Spectral Analysis

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Fine Pitch LED Display System

Datasheet. Shielded airmax Radio with Isolation Antenna. Model: IS-M5. Interchangeable Isolation Antenna Horn. All-Metal, Shielded Radio Base

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

SPECIFICATION NO NOTE

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

HDMI over CAT5 HDBaseT Extender - 4K

X-ray inspection system Dymond

Engineered to meet your needs T he oldest name in stud welding,

Re-defining the utility-scale inverter

OM2000N INSTALLATION MANUAL

VPL-HW45ES Home Theater Projector

Truck router (3Gbps/HD/SD/ASI)

Datasheet. High-Performance airmax Bridge. Models: NBE M5-19, NBE-M5-16. Uniform Beamwidth Maximizes Noise Immunity. Innovative Mechanical Design

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

CBF500 High resolution Streak camera

DB-VRC4H 4K HDMI Compact Video Wall Controller with 45 degree screen rotation

OTS-300 Express Series Power Meters/Sources and Testers

Specifications SMART Board 6075 interactive flat panel with iq Model SPNL-6275

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

NEXT/RADIUS Shelf Mount CCU

IMPAC Infrared Thermometers

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Grid. Grid. Next-Gen Broadband Wireless CPE Technology. Datasheet. 4Gon Tel: +44 (0) Fax: +44 (0)

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

IMPAC Infrared Thermometers

Coronis Uniti (MDMC-12133) 12MP diagnostic display system for PACS and breast imaging

SPECIFICATION NO Model 207 Automatic GTAW Welding System

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

More reliable zeta potential measurements. without dilution. Agilent Particle Analysis Solutions. Agilent 7020 ZetaProbe Zeta Potential Analyzer

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

SP-10. Sports Perimeter (SP) solution - optimized for Broadcast

Fluorescence Spectrophotometer

Dell Wyse 5030 PCoIP Zero Client

XPert Filtered Balance Systems

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

Research-Grade Research-Grade. Capture

Optical Component Environmental Test System

specification display applications cronus spectrometer & colorimeter

User Guide. HDMI Active Cable Extender. DVI-7370c

If you have questions or problems in providing anything described as Customer

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

Datasheet. Carrier Backhaul Radio. Model: AF-2X, AF-3X, AF-5X. Up to 687 Mbps Real Throughput, Up to 200+ km Range

IKA Analytical line Calorimeters C 2000

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing

TROJANUVTORRENTTM. Drinking Water Disinfection

Product Brochure. June M5 Series. Metal Detector

CORIO master C3-540 Series

Datasheet. Shielded airmax Radio with Isolation Antenna. Model: IS-M5. Interchangeable High-Isolation Horn Antenna. All-Metal, Shielded Radio Base

Forced Convection Laboratory Ovens

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

NanoBridge. NanoBridge. Hi-Performance & Cost-Effective MIMO Bridging. Datasheet. Models: NBM9, NBM2, NBM3, NBM365, NBM5. Hi-Performance, Long Range

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

Datasheet. Dual-Band airmax ac Radio with Dedicated Wi-Fi Management. Model: B-DB-AC. airmax ac Technology for 300+ Mbps Throughput at 5 GHz

Practicality and Performance

VGA to DVI Extender over Fiber SET

Transcription:

ABB MEASUREMENT & ANALYTICS MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

2 M B 3 6 0 0 T H E M O S T R E L I A B L E F T- N I R L A B O R ATO R Y A N A LY Z E R D E S I G N E D F O R Q A /Q C Measurement made easy The MB3600 is the result of many years of experience in the space, academic, chemical, pharmaceutical and petrochemical industries. Designed with the concerns of lab users in mind, the MB3600 is the ultimate in ease of use, reliability and consistency.

MB3600 THE MOST RELIABLE FT-NIR LABORATORY ANALYZER DESIGNED FOR QA/QC 3 Contents 04 MB3600 FT-NIR spectrometer for your industry 05 MB3600 features 06 MB3600: Horizon MB software suite 07 Specification

4 MB3600 THE MOST RELIABLE FT-NIR LABORATORY ANALYZER DESIGNED FOR QA/QC MB3600 FT-NIR spectrometer for your industry 01 The MB3600 laboratory analyzer with a powder sampler to measure chemical products. The optimum NIR analyzer solution The MB3600 FT-NIR with Horizon MB FTIR software provides an optimum combination of reliability, low cost of ownership, consistency of results over a long time and spectroscopic performance. Easy to use and maintenance free, it will provide consistent analytical results for years to come. Durability Built with heavy-duty modules, a permanently aligned optical system and minimal mechanical components, the MB3600 does not require maintenance or adjustments for years to come. The result: a reliable spectrometer that produces the most consistent results. Designed by Dr. Henry Buijs The MB3600 was developed by Dr. Henry Buijs, one of the founders of Bomem Inc. and a worldrenowned expert recognized for his applied research in spectroscopy. The MB3600 laboratory analyzer is the successor to the FTLA2000 spectro meter, also developed by Dr. Buijs and marketed since 1985 by Bomem Inc. Patented The double-pivot interferometer s innovative design ensures increased robustness. The optics are permanently aligned, enabling more repeatable, reproducible spectroscopy and eliminating the need for dynamic alignment. The scanning mechanism has a lifetime guarantee. Smallest footprint With a vertical, space-efficient design, the MB3600 optimizes laboratory workspace and facilitates access to internal components. First maintenance-free FT-NIR analyzer No consumables The MB3600 contains fixed components that do not wear out with use, meaning no components to replace or adjust. With the MB3600, the HeNe LASER is replaced by a solid state laser. All optics are non-hygroscopic. Purging is not required for protection of optics. Long-life source To maximize reliability, the source is operated so as to provide a 10-year expected lifetime. 01

MB3600 THE MOST RELIABLE FT-NIR LABORATORY ANALYZER DESIGNED FOR QA/QC 5 MB3600 features ABB s world-class laboratory FT-NIR analyzers deliver maximum reliability for consistent results and minimal maintenance. 02 Swappable accessories can be used with the MB3600; Universal vial holder, powder sampler and liquid cell. Reliable, consistent results Permanently aligned optical system. With permanently aligned optics using only fixed components along with a patented interferometer scan mechanism, the MB3600 delivers consistent precise and reproducible results year after year and from unit to unit. Heavy-duty, reliable components The modular components of the MB3600 have been designed to provide the longest product life on the market. The MB3600 s design is based on the following principles: No maintenance, no adjustments and a scan mechanism that has no wear. The reliability of the MB3600 comes from dependable components and their integration in a system requiring minimal moving parts. Unprecedented spectral performance Permanently aligned optics with a Jacquinot stop in the interferometer output beam ensures an accurate and stable line shape as well as wavelength and resolution stability. The 100% line spectral repeatability permits reliable determination of small spectral features down to below 10 micro absorbance and below 2 micro absorbance for the optional high sensitivity InAs or InGaAs detectors. The MB3600 is provided with a highly accurate internal wavelength calibration standard. Versatility at a glance Standard open sample compartment The arid-zone open sample compartment of the MB3600 addresses all the needs of the modern analytical laboratory. It can hold a wide variety of easily swappable ABB or third-party accessories that do not require alignment. The instrument can also be purged if needed. Multiple sampling options ABB offers a number of well thought-out accessories that are easily swappable. They do not require alignment. The temperature-controlled vial holder is a universal vial sampling accessory for the analysis of liquids in disposable glass vials with diameters of 5 mm, 8 mm and 12 mm OD. The rotating diffuse reflectance accessory measures a large sample area while the sample is moving, providing better averaging than a stationary integrating sphere. A fiber-optic coupled disposable temperature controlled vial accessory and temperature controlled liquid cell are also available. 02

6 MB3600 THE MOST RELIABLE FT-NIR LABORATORY ANALYZER DESIGNED FOR QA/QC MB3600: Horizon MB software suite 01 The Horizon MB FTIR software package offers multiple modules to address specific needs. Horizon MB FTIR (standard package) The Horizon MB FTIR module facilitates the acquisition, processing and analysis of samples. All the available functions are packaged in modules, so you only pay for what you need. Horizon MB IR Interpretation The Horizon MB IR Interpretation module is used to analyze IR spectra in fully-automated, semiautomated or manual modes. Easily identify functionnal groups using the IR interpretation rule database. Optional modules Horizon MB Professional The Horizon MB Professional module includes enhanced mathematical functions, 3D capabilities and extended import/export functions. It also includes a regulatory module for automated execution and reporting of the instrument verification tests described in the pharmacopoeia guidelines. Horizon MB Library The Horizon MB Library module is designed for efficient multiple library searches. It offers spectrum and full-text search capabilities with custom and commercial library. Horizon MB FTIR Reaction Monitoring The reaction monitoring module provide all functions to collect and analyse real-time spectra generated during chemical experiments. The user is taken through the different steps of the experiment setup thanks to a reaction configuration wizard. The system can generate multiple real-time trends of spectral features or chemical properties. Horizon MB Quantify The Horizon MB Quantify module incorporates univariate and multivariate algorithms like PLS and MLR for data analysis and quantification. It also includes the Horizon MB Professional module. Horizon MB Security The Horizon MB Security module offers 2 selectable security levels. It provides distinctive access control to software functions based on permission schemes, hierarchical access control based on data access roles, electronic signatures, activity logging and traceability of all data manipulations. Horizon MB Scripting The Horizon MB Scripting module enables users to develop their own routines and functions using the script recorder or writing code directly for the SAX basic scripting engine. 01 Horizon MB QA The Horizon MB QA module is designed to facilitates routine analysis for lab and at-line quality assurance and quality control. Includes extensive reporting capabilities.

MB3600 THE MOST RELIABLE FT-NIR LABORATORY ANALYZER DESIGNED FOR QA/QC 7 Specification Spectroscopic performance (typical, at 25 C) Spectral range with DTGS detector 3,700 to 15,000 cm -1 Spectral range with InAs detector 3,700 to 12,000 cm -1 Spectral range with InGaAs detector 3,900 to 11,000 cm -1 Resolution better than 0.7 cm -1 Apodized resolution adjustable 1 cm -1 to 64 cm -1, in increments of 2 Signal-to-noise ratio (RMS, 60 s, 16 cm -1, at peak response) with DTGS detector: > 100,000: 1 Signal-to-noise ratio (RMS, 60 s, 16 cm -1, at peak response) with InAs detector: > 500,000: 1 Signal-to-noise ratio (RMS, 60 s, 16 cm -1, at peak response) with InGaAs detector: > 600,000: 1 Signal sampling: 24-bit ADC Short-term stability (@ 8,000 cm -1 ): < 0.09 % Temperature stability (@ 8,000 cm -1 ): < 1 % per C Frequency repeatability (@ 7,300 cm -1 ): < 0.006 cm -1 Frequency accuracy (@ 7300 cm -1 ): < 0.06 cm -1 Absorbance reproducibility (toluene): < 0.002 AU Application software (computer not included) Operating system compatibility Win 7 Standard software: Horizon MB FTIR Optional modules: Horizon MB Professionnal, Quantify, Library IR Interpretation, Reaction Monitoring, Security (21CFR part 11 compliance), Scripting, QA Optical bench Beamsplitter material ZnSe (non-hygroscopic) Patented double pivot interferometer mechanism. High throughput Michelson interferometer with protective cover. Optical path fully purgeable Source, quartz halogen with electronic stabilization, expected half life, 10 years Metrology: solid-state laser (no scheduled maintenance required) Detector module: DTGS Optional detector modules, InAs and extended InGaAs both with integrated cooling Open sample compartment configuration: Arid-zone, center focus Sample compartment dimensions: 20 x 14 cm (7.8 x 5.5 in) plate, 8.7 cm (3.1 in) beam height Sample compartment mounting: 3-point positioning guide or 3-point kinematic adjustable Accessory information interface USB connection between PC and accessory Temperature reading (when applicable) Temperature adjust (when applicable) ID serial number Factory acceptance test with data Instruction manual Data communication Hardware port Ethernet, 10/100 Mbps Instrument enclosure Casting: rugged all-metal with integral handles Dimensions (H x W x D): 37 x 43.5 x 28 cm (14.5 x 16.9 x 11 in) Weight: 24 kg (52.9 lbs) Environmental Universal power supply: 100 to 240 VAC, 50/60 Hz Power consumption: 65 W Operating temperature: 10 C to 35 C (50 F to 95 F) Operating relative humidity: 5% to 80%, non-condensing Regulatory certification and compliance: TUV and CE Documentation cgmp IQ-OQ protocol templates (optional) User manual Quick-start guide

ABB Inc. Measurement & Analytics 3400, Rue Pierre-Ardouin Québec (Québec) G1P 0B2 Canada Tel.: +1 418 877-2944 1 800 858-3847 (North America) Fax: +1 418 877-2834 Email: ftir@ca.abb.com abb.com/analytical Additional information We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2018 ABB. All rights reserved. Specifications subject to change without notice. PB/MB3600-EN Rev. B Letter 04.2018