SSRF Beam Diagnostics Commissioning. LENG Yongbin on behalf of SSRF BI group

Similar documents
Brilliance. Electron Beam Position Processor

Accelerator Systems of the TPS

Digital BPMs and Orbit Feedback Systems

SPEAR 3: Operations Update and Impact of Top-Off Injection

Fast Orbit Feedback at the SLS. Outline

LHC Beam Instrumentation Further Discussion

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

First Simultaneous Top-up Operation of Three Different Rings in KEK Injector Linac

NSLS2 Diagnostic System Commissioning and Measurements

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

ALBA. Libera Workshop 16 A. Olmos

The Elettra Storage Ring and Top-Up Operation

Bunch-by-bunch feedback and LLRF at ELSA

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

Beam Position Monitor Developments at PSI

PEP-II longitudinal feedback and the low groupdelay. Dmitry Teytelman

The Backlog The Scope The Approach The Trends

Precision measurements of beam current, position and phase for an e+e- linear collider

COMMISSIONING OF THE ALBA FAST ORBIT FEEDBACK SYSTEM

North Damping Ring RF

NSLS-II RF BEAM POSITION MONITOR COMMISSIONING UPDATE

Sérgio Rodrigo Marques

1 Digital BPM Systems for Hadron Accelerators

Libera Hadron: demonstration at SPS (CERN)

Recent APS Storage Ring Instrumentation Developments. Glenn Decker Advanced Photon Source Beam Diagnostics March 1, 2010

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

PEP II Design Outline

ANKA Status Report. N.Smale, A.-S. Müller, E. Huttel, M.Schuh Slides courtesy of A.-S. Müller and C.Heske.

New Filling Pattern for SLS-FEMTO

Top-Up Experience at SPEAR3

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

LLRF at SSRF. Yubin Zhao

Development of BPM Electronics at the JLAB FEL

Session 07 - What did we learn with beam in 2008? LHC Performance Workshop Chamonix Rhodri Jones on behalf of BE/BI & all our collaborators

Diamond RF Status (RF Activities at Daresbury) Mike Dykes

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

RF considerations for SwissFEL

LIGHT PROTON THERAPY PROJECT

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

BEPCII Libera Control System

Diagnostics Development in SRRC

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera

Linac 4 Instrumentation K.Hanke CERN

CBF500 High resolution Streak camera

ANKA RF System - Upgrade Strategies

Low Level RF for PIP-II. Jonathan Edelen LLRF 2017 Workshop (Barcelona) 16 Oct 2017

Status of SOLARIS Arkadiusz Kisiel

INTRODUCTION. SLAC-PUB-8414 March 2000

GFT Channel Digital Delay Generator

BUNCH BY BUNCH FEEDBACK SYSTEMS FOR SUPERKEKB RINGS

ANKA Status Report. N.Smale, on behalf of all ANKA colleagues, Directors : A.-S. Müller, C Heske, T Baumbach.

Production of quasi-monochromatic MeV photon in a synchrotron radiation facility

Detailed Design Report

JLab 10kW FEL Driver Beam Diagnostics

Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

4.4 Injector Linear Accelerator

Status of the X-ray FEL control system at SPring-8

Status of SOLARIS. Paweł Borowiec On behalf of Solaris Team

Status of Elettra, top-up and other upgrades

COMMISSIONING SCENARIOS FOR THE J-PARC ACCELERATOR COMPLEX

Beam Instrumentation for X-ray FELs

THE DESIGN OF CSNS INSTRUMENT CONTROL

THE SLS BEAMLINES DATA ACQUISITION AND CONTROL SYSTEM

LCLS Injector Technical Review

beam dump from P2 losses this morning

Position Resolution of Optical Fibre-Based Beam Loss Monitors using long electron pulses

Operational experience with the SOLEIL LINAC and Status of the ThomX LINAC project

The 2011 LHC Run - Lessons in Beam Diagnostics

Jae-Young Choi On behalf of PLS-II Linac team

FIRST SIMULTANEOUS TOP-UP OPERATION OF THREE DIFFERENT RINGS IN KEK INJECTOR LINAC

G0 Laser Status Parity Controls Injector Diagnostics

Summary report on synchronization, diagnostics and instrumentation

Accelerator Instrumentation RD. Monday, July 14, 2003 Marc Ross

Beam Loss Detection for MPS at FRIB

Operation and Performance of a Longitudinal Feedback System Using Digital Signal Processing*

P. Emma, et al. LCLS Operations Lectures

Phase (deg) Phase (deg) Positive feedback, 317 ma. Negative feedback, 330 ma. jan2898/1638: beam pseudospectrum around 770*frev.

PEP-II Overview & Ramp Down Plan. J. Seeman DOE PEP-II Ramp Down-D&D Review August 6-7, 2007

Screen investigations for low energetic electron beams at PITZ

KARA and FLUTE RF Overview/status

Zynq platform and related instruments

Beam Diagnostics for the BNL Energy Recovery Linac Test Facility

Feedback Control of SPS E-Cloud/TMCI Instabilities

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

CLIC Feasibility Demonstration at CTF3

2008 JINST 3 S LHC Machine THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS. Lyndon Evans 1 and Philip Bryant (editors) 2

PITZ Introduction to the Video System

Photoinjector Laser Operation and Cathode Performance

Polarized Source Development Run Results

The FLASH objective: SASE between 60 and 13 nm

BUNCH-BY-BUNCH DIAGNOSTICS AT THE APS USING TIME- CORRELATED SINGLE-PHOTON COUNTING TECHNIQUES*

MULTI-BUNCH INSTABILITY DIAGNOSTICS VIA DIGITAL FEEDBACK SYSTEMS AT PEP-II, DAæNE, ALS and SPEAR

CONSTRUCTION AND COMMISSIONING OF BEPCII

Choosing an Oscilloscope

4 MHz Lock-In Amplifier

Synthesized Clock Generator

The PEFP 20-MeV Proton Linear Accelerator

DESIGN AND DEVELOPMENT OF CONFIGURABLE BPM READOUT SYSTEM FOR ILSF

Control of Intra-Bunch Vertical Motion in the SPS with GHz Bandwidth Feedback

Transcription:

SSRF Beam Diagnostics Commissioning LENG Yongbin on behalf of SSRF BI group 2009.05.25

Outline Instruction of SSRF Overview of SSRF BI system Subsystem Beam position monitor Tune monitor Current & charge monitor Diagnostics beam line Transverse feedback Status of other components Summary

Shanghai Synchrotron Radiation Facility

SSRF complex

Ring Parameters

Beam lines in the first stage

Construction schedule

Time Milestone for BI system 2001 ~ 2004 Preliminary research & design 2004.12.25 Project start 2005.04.12 Internal design review Events 2005.05.30 International design review (Bob, Guenther, JC, Sun Baogen, Cao Jianshe) 2007.05.15 Linac diagnostics ready in day one for Linac 2007.09.30 Booster diagnostics ready in day one for Booster 2007.12.21 BPM, DCCT, TM, parts of SRM ready in day one for Ring 2008.06.18 Interferometer online 2008.11.01 Streak camera & gated camera online 2008.12.19 Transverse feedback online 2009.03.31 System performance evaluation, targets achieved

Primary requirements measurements Ring Booster Linac&TL Beam position 10um @ 694kHz 1um @ 10Hz 100um @ 1.67MHz Tune 0.0001 @ 1Hz 0.001 @ 200Hz Current / Charge 10uA @ 1Hz 50uA @ 10kHz 2% Profile / Size 10um 200um 200um Bunch length 2ps Energy 0.1% Other components Transverse feedback 1 Slit/Scraper 1 3 Fast orbit feedback 1 100um @ single pass

System design LN LTB BS BTS SR Purpose Stripline BPM 3 3 50 5 Beam position, longitudinal distribution Button BPM 152 Beam position, bunch charge, filling pattern PCT 1 1 Average current, lifetime WCM 5 2 1 3 Bunch charge, longitudinal distribution ICT 1 1 1 Bunch charge Faraday Cup 1 Bunch charge Screen Monitor 5 3 4 4 2 Profile, energy, emmitance for Linac & TL Tune Monitor 1 1 Tune measurement Slit 2 1 Energy purity Scraper 2 Machine study, collimator Diagnostics BL 1 Profile, transverse beam size, bunch length Transverse FB 1 Beam stability Orbit FB 1 Orbit stability Total 15 11 57 14 161

DAQ Hardware & software platform subsystem Sensors Electronics DAQ/Control Beam position Button/stripline Libera Linux embedded IOC Bunch charge WCM/ICT/FC Oscilloscope Windows embedded IOC Tune Stripline kicker Function generator HTTP access Trans profile Phosphor / OTR CCD PXI IOC+ image grabber Beam current NPCT175 Bergoz PXI IOC + DMM Slit / Scrapper Step motor Motor driver PXI IOC + Motion controller Trans feedback Stripline kicker Spring-8 board PXI IOC + DI/O Filling pattern Button RF front-end PXI IOC + waveform recorder Beam size SRM Interferometer (CCD) PXI IOC + image grabber Beam length SRM Streak camera IPC + image grabber Timing EVR VME (VxWorks) IOC PXI IOC talks to EPICS through Shared Memory IOCcore, which wins due to We had experiences before Easy to learn and use for new players Easy to move from lab test system to field system Easy to modify and debug in the field

DAQ System Architecture Central control room Linux OPI Linux OPI Linux SoftIOC EDM panel CA Client Channel Access VME IOC Libera IOC PXI IOC Scope IOC 1 units 3 units 1 units 1 units Linac VME IOC Libera IOC PXI PXI IOC Scope IOC 2 units 38 units 3 units 2 units Booster & tranport lines Control network / EPICS Channel Access CA Server Running DB Record Support Device Support vxworks driver VME HW CA Server Running DB Record Support Device Support CSPI Linux driver Libera HW CA Server Running DB Record Support Device Support Shared Memory SM DLL SM LabVIEW Interface LabVIEW Application LabVIEW Driver PXI HW CA Server Running DB Record Support Device Support VISA Virtual GPIB Scope HW VME IOC Libera IOC PXI PXI IOC Scope IOC 11 units 142 units 4 units 1 units Storage Ring VME IOC Libera IOC PXI IOC scope IOC 13 BI stations + 1 SRM lab, total 212 IOCs Five kinds of IOCs used: VME, Libera, PXI, Scope, Soft

Beam Position Monitor Ring Booster Linac & TL Design goals Achievement 1um @ 10Hz < 200nm @ 10Hz 10um @ 694kHz < 3um @ 694kHz 100um @ 1.67MHz < 50um @ 1.67MHz 100um @ SP < 33um @ SP

BPM System Architecture OPI High level application BPM processors Libera Control network / EPICS CA Timg fiber network Timing IOC trigger Digital Digital Digital Digital BPM BPM BPM BPM processor processor processor processor... next station Beam diagnostics station #i 14 units BPM signal feeding network Cable panel Cable tray... ID ID BPM BPM Arc Arc BPM Arc BPM Arc BPM Arc BPM BPM ID ID BPM BPM Arc Arc BPM Arc BPM Arc BPM Arc BPM BPM Shielding wall... 2 IDBPMs & 5 ArcBPMs Cell #17 Cell #18 2 units 5 units 2 units 5 units Cell #2i Cell #2i-1 Storage Ring Cell #4 Cell #3 Pickup assembly Cell #19 Cell #20 Cell #1 Cell #2

BPM data & functions Support by Diamond Light Source package ADC raw data @ 117MHz, 2048 points First turn data synchronized by injection trigger First 2048 samples of TBT data synchronized by injection trigger Up to 0.5M samples of TBT data on demand 10Hz SA data, orbit measurement Embedded position interlock logic User defined current scaling factor (beam current measurement) Instrumentation Technologies delivered 10kHz FA data @ SFP port SSRF added some applications 24 hours buffer for SA data @ EPICS DB level Auto Gain Control logic @ EPICS DB level Beam lifetime measurement @ EPICS DB level Phase advance measurement @ EPICS DB level

Ring BPM resolution evaluation COD resolution: typical <200nm, best <80nm, with ideal beam <40nm TBT resolution: typical 3um Uniformity of filling pattern is important for BPM performance BPM resolution (μm) 1 0.8 0.6 0.4 0.2 SSRF Ring BPMs resolution test @ 2009.03.31 Average of all 140 BPMs 0 0 20 40 60 80 100 120 140 160 180 200 Beam current (ma) COD resolution, BW 2Hz BPM readings STD (nm) @ 10Hz Ring BPM resolution test @ 202mA top-up operation 240 2009.04.16 200 160 120 80 40 08BPM3 10BPM1 10BPM3 14BPM7 16BPM5 10BPM5, electronics evaluaiton setup 0 0 20 40 60 80 100 120 140 BPM index COD resolution @ topup operation TBT resolution, BW 350kHz 30 SSRF Ring 140 BPMs rms noise histgram @ 0.2mA 12 SSRF Ring 140 BPMs rms noise histgram @ 0.9mA 14 SSRF Ring 140 BPMs rms noise histgram @ 10.1mA 16 SSRF Ring 140 BPMs rms noise histgram @ 199.5mA 25 10 12 14 Counts 20 15 Counts 8 6 Counts 10 8 6 Counts 12 10 8 10 4 4 6 4 5 2 2 2 0 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 BPM resolution varation (μm) 0 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 BPM resolution varation (μm) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 BPM resolution varation (μm) 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 BPM resolution varation (μm) 0.2mA 1mA 10mA 200mA

Tune Monitor Ring Booster Design goals Achievement 0.001 @ 200Hz 0.001 @ 800Hz 0.0001 @ 1Hz 0.0001 @ 1Hz

Tune monitor configuration Configuration is the same for Booster and Ring

Tune monitor performance: Ring Typical TBT data during tune measurement Daily operation panel Daily operation: FFT of 10k TBT data, uncertainty < E-4 Precise tune measurement

Tune monitor performance: Booster Horizontal ramping tune Vertical ramping tune Tune drift during ramping TBT data 400k samples, cover 240ms FFT windows size 2048, 1/1.23us = 800Hz Tune measurement uncertainty < E-3

Current & Charge measurement Design goals Achievement Ring DCCT 10uA @ 1Hz 2uA @ 1Hz Booster DCCT 50uA @ 10kHz 30uA @ 10kHz 10uA @ 2Hz ICT 2% 1% @ 2Hz

Sensors layout 1 DCCT @ Booster 1 DCCT @ Ring 1 ICT @ Linac 1 ICT @ LTB transfer line 1 ICT @ BTS transfer line Transfer efficiency could be fully evaluated with this configuration BPM + combiner @ Ring Bunch charge & filling pattern

Average current measurement: DCCT Shield design borrowed from SPEAR3 Bergoz NPCT175 NI 4070 DVM NI 8187 PXI controller

DCCT readings / I DCCT (ma) Current readings deviation (μa) 350 300 250 200 150 100 1.6 1.5 1.4 1.3 1.2 1.1 0.9 50 DCCT performance evaluation SSRF Ring DCCT linearity test @ 2009.03.31 Measured data Linear fitting I DCCT = I INPUT * A + B A = 1.000327 ± 0.000005 B = 0.0189 ± 0.0009 0 0 50 100 150 200 250 300 Calibration current setting / I INPUT (ma) 1 SSRF DCCT resolution test @ 2009.03.31 real beam current calibrator 0.8 0 50 100 150 200 250 300 Input current (ma) Ring Resolution < 2uA @ 1Hz Nonlinearity < 0.03% @ 0 ~ 300mA DCCT readings / I DCCT (ma) Current readings deviation (μa) 7 6 5 4 3 20 18 16 14 12 10 8 6 4 2 SSRF Booster DCCT linearity test @ 2009.04.10 Measured data Linear fitting I DCCT = I INPUT * A + B A = 0.99938 ± 0.00018 B = -0.0007 ± 0.0016 0 0 2 4 6 8 10 12 14 16 18 20 Calibration current setting / I INPUT (ma) SSRF Booster DCCT resolution test @ 2009.03.31 Current calibrator 2 1 1.2 1.6 2 4 6 8 10 12 14 16 18 20 Input current (ma) Booster Resolution < 30uA @ 10kHz, < 10uA @ 2Hz Nonlinearity < 0.07% @ 0 ~ 20mA

Bunch charge measurement: ICT Scope embedded IOC TEK DPO7054 BW 500MHz 20 ICT raw waveform acquired by scope IOC 0-20 Amplitude (mv) -40-60 -80-100 -120-140 Bergoz ICT -160 0 20 40 60 80 100 120 140 160 180 200 Time (ns) Counts 120 100 80 60 40 ICT resolution test @ 2009.03.31 Total samples1000 Average = 1.067nC STD = 9pC 0.009 / 1.067 = 0.8% 20 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.1 1.11 ICT readings (nc) 1000 samples RMS: 0.009/1.067nC = 0.8% P-P: 0.06/1.067 = 5%

Bunch charge measurement: BPM Storage ring filling pattern @ 2009.04.14 0.7 0.6 Bunch charge (nc) 0.5 0.4 0.3 0.2 0.1 1 Acquiris DC252, BW 2GHz Sampling rate 8GHz PXI BCM test @ 2009.04.14 BCM full range = 1nC, readings STD = 0.9pC 0 250 100 200 300 400 500 600 700 Bunch ID PXI BCM readings, average = 0.23nC, STD = 0.9pC Bunch ID = 96 Bunch charge (nc) 0.8 0.6 0.4 0.2 Bunch ID 304 ~ 306, lifetime ~ 14 hours Bunch ID 311 ~ 314, lifetime ~ 18 hours Bunch ID 308 ~ 310, lifetime ~ 21 hours Counts 200 150 100 50 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Time (hours) 2000 samples RMS: 0.9pC/1.0nC = 0.1% 0-5 -4-3 -2-1 0 1 2 3 4 Bunch charge readings varation (pc)

Diagnostics Beam Line Design goals Achievement Beam size 10um 10um Beam length 2ps 2ps

Layout #2 BM I the cell #2

Diagnostics beam line: bench setup Removable mirror V interferometer From source point 1677cm 15 100 20 25 45 150 CCD 130 25 145 CCD 20 970 17 230 25 Horizontal 217 Vertical Gated Camera 100 45 H interferometer Imaging Streak camera Gated camera 55 Streak Camera Removable mirror 15 CCD Mirror Half mirror Lense Double slit

Diagnostics beam line: image system 2008.01.03 80mA, no COD correction copper cavity 2008.04.10 100mA, COD um level copper cavity 2008.10.01 150mA SC cavity, noisy PS 2008.10.27 86mA SC cavity, noisy PS fixed

Diagnostics beam line: Interferometer Counts 100 80 60 40 20 Vertical beamsize = 34.3±0.4μm @ 2009.04.16, 202.2mA 0 33 33.5 34 34.5 35 35.5 Beam size readings varation (μm) Counts 60 50 40 30 20 10 Horizontal beamsize = 52.1±0.3μm @ 2009.04.16, 190.7mA 0 50 50.5 51 51.5 52 52.5 Beam size readings varation (μm) Measured beam size (μm) 110 100 90 80 70 60 50 40 30 20 Horizontal beam size Vertical beam size 20 40 60 80 100 120 140 160 180 200 Beam current (ma) Measurement uncertainty um level, system resolution better than 10um

Transverse Feedback Bandwidth System gain Design goals 250Mhz Achievement 250Mhz > 40dB

Transverse feedback Stripline kicker @ injection section, BPM pickups @ #2 straight section Spring8 designed digital feedback processor In-house made separate stripline kicker in-house made RF front-end Betatron oscillation attenuation > 40dB

Transverse feedback performance SSRF multibunch transverse feedback system test @ 2009.01.20 110 3.5GeV, SC RF Current = 140mA Vertical beamsize (μm) 90 70 50 30 Feedback ON, δ V = 32±4μm Feedback OFF, δ V = 101±2μm Feedback ON 0 5 10 15 20 Time (minutes) 10 2 Beam power spectrum @ 3.5GeV, 140mA, MBTF OFF 197.2kHz / 0.2842 Amplitude = 29 X plane Y plane 10 2 Beam power spectrum @ 3.5GeV, 140mA, MBTF ON X plane Y plane PSD (um 2 /Hz) 10 0 10-2 10-4 299.6kHz / 0.4317 Amplitude = 2.2E-4 PSD (um 2 /Hz) 10 0 10-2 10-4 195.5kHz / 0.2817 Amplitude = 5.8E-4 System gain 29/7E-4 > 40dB 10-6 0 50 100 150 200 250 300 Frequency(kHz) 10-6 0 50 100 150 200 250 300 Frequency(kHz)

Status of the other components Screen monitor is daily operation toolkits for Linac & TL important in day one commissioning for both booster & ring Slit is rarely used now used few times during booster commissioning Scraper is very useful for machine study used as collimator to protect IDs in daily operation WCM is rarely used now good tools for operator in commissioning stage Fast orbit feedback is under commissioning

LINAC LTB BTS BS SR Summary (1) Measurement Specification Achievement Beam position Resolution 100μm@2Hz < 33um @ SP Beam profile Resolution 200μm@2Hz 200um @ 2Hz Bunch charge Relative accuracy 2% 1% Energy Relative accuracy 0.1% 0.1% Emmitance Relative accuracy 10% 10% Beam position Resolution 100μm@1.67MHz < 50um@1.67MHz Beam profile Resolution 200μm@2Hz 200um @ 2Hz DC current Resolution 50μA@10kHz 30uA@10kHz 10uA@2Hz Tune Resolution 0.001@200Hz 0.001@800Hz Beam position Resolution 10μm@694kHz 3um @ 694kHz Resolution 1μm@10Hz 200nm @ 10Hz Beam profile Resolution 10μm 10um Beam length Resolution 2ps 2ps DC current Resolution 10μA@1Hz 2uA @ 1Hz Tune Resolution 0.0001@1Hz 0.0001@1Hz MBTF BW 250MHz BW 250MHz, -40dB gain

Summary (2) Beam diagnostics meets all physical requirements All necessary diagnostics tools ready in day one for commissioning Adopting new technologies and methods accelerates system development and implementation All design goals achieved except fast orbit feedback Fast orbit feedback could be online this year We need keep working on stability & reliability issues

Acknowledgments The development of SSRF beam diagnostics is a successful story of international collaboration. Without comments, suggestions from accelerator community we could not make it. In particularly many thanks to Guenther Rehm and Michael Abbott from Diamond Light Source Bob Hettel, Jim Sebek, James Safranek, Jeff Corbett from SLAC Tadayoshi Misuhashi from KEK Takeshi Nakamura from Sring8 Jean-Claude Denard from Soleil Light Source Hsu Kuo-Tung from Taiwai Light Source Cao Jian-She She and Ma Li from IHEP Sun Bao-Geng Geng from NSRL We hope we can do more contribution to this community in the future.