IEFIS G3 Inputs, outputs and Alarms

Similar documents
COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

Operating Instructions

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

HS-509 VIBRATION TRIP MODULE

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

DPM 942-FPSI 4-20mA Loop Meter with Programmable Backlighting

Click Here To Start Demo

B. Sc. III Semester (Electronics) - ( ) Digital Electronics-II) BE-301 MODEL ANSWER (AS-2791)

Noise Detector ND-1 Operating Manual

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

843-R 843-R LASER POWER METER USER MANUAL. NEWPORT CORPORATION

SCALE & WEIGHT DISPLAYS

Night Hawk Firing System User s Manual

ECB DIGITAL ELECTRONICS PROJECT BASED LEARNING PROJECT REPORT ON 7 SEGMENT DIGITAL STOP WATCH USING DECODER

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

Modbus for SKF IMx and Analyst

Complete Train Control. Run Your Trains, Not Your Track!

Understanding VFD. Variable Frequency Drive. nfi. nfi

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

DZ143. Z Scale. Mobile Decoder 1.25 Amp/2 Amp Peak 4 FX 3 Functions, 0.5 Amp. Fits Many Z, N and HO Scale Locomotives

802DN Series A DeviceNet Limit Switch Parameter List

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

DMC550 Technical Reference

Single Axis Position Controller

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

MXS Strada USER GUIDE

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

MT03A Electronic converter for flow rate transmitters

Model IQ4-PC User Manual Revision Date:

CARLO GAVAZZI Automation Components

Nixie Clock Type Frank 2 Z570M

Part names (continued) Remote control

K3NX Process Meter OPERATION MANUAL

OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE.

16 Stage Bi-Directional LED Sequencer

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

IV 251. Signal Converter SSI => Analogue and SSI => Serial. Operating Instructions. control motion interface

STX Stairs lighting controller.

(Cat. No IJ, -IK)

MATE3 Owner s Manual Addendum

FD-128D FiberDriver - DMX Fiber Optic Illuminator

Operating instructions Electronic preset counter Type series 717

Electronic converter for level transmitters MT03L Instructions manual

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

16-BIT LOAD CELL/DUAL STATUS INPUT

Registers type ILR7XX and ILR7XXT

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Channel Controller for Light Show with Remote Control. HomLiCon RCL164R

MILLITARY SPECIFICATION SHEET

Sentinel I24 Digital Input and Output Configuration

800 Displaying Series Flowmeter

Complete Train Control. Run Your Trains, Not Your Track!

Chapter 23 Dimmer monitoring

MICROMASTER Encoder Module

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global

SceneStyle2 User Guide

Technology Control Technology

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

CNV-ALT. Introduction. 1 Features. Serial altitude to parallel Gillham code converter for mode C transponders. Operating Manual English 1.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Introduction. Serial In - Serial Out Shift Registers (SISO)

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

LAUREL ELECTRONICS, INC.

Smart Hawk Firing System User s Manual

Complete Train Control. Run Your Trains, Not Your Track!

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

2002 Martin Professional A/S, Denmark.

IV 251. Signal Converter SSI Analogue and SSI Serial. Operating Instructions. control motion interface

KNX Dimmer RGBW - User Manual

ST350 Radiation Counter

GC30 Digital Differential Pressure Gauge Operation Manual

SPACESCAN SERIES SS 02

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Lab 2: A/D, D/A, and Sampling Theorem

4125 system setup and deployment quick start guide

Nixie Clock Type Quattro'

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Complete Train Control. Run Your Trains, Not Your Track!

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

Micro-DCI 53ML5100 Manual Loader

During recoveries from unusual attitudes, level flight is attained the instant

Is this the end of the Digital Panel Meter as we know it?

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

User s Manual. Log Scale (/LG) GX10/GP10/GX20/GP20 IM 04L51B01-06EN. 1st Edition

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

LeRIBSS MTC MANUAL. Issue #1. March, MTC Control Unit Definitions, Information and Specifications. MTC Control Unit Electronic Schematics

5024 WEIGHING TERMINAL

OPERATING INSTRUCTIONS

Revision 1.2d

DH165A0 Fits Athearn, Genesis, Kato, Stewart, Atlas & Other HO Locomotives

LE-650s Instruction Manual

THE ASTRO LINE SERIES GEMINI 4000 INSTRUCTION MANUAL

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

SCENEMASTER 3F QUICK OPERATION

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Transcription:

IEFIS G3 Inputs, outputs and Alarms Document version: 2, May 2016 User manual on the use and configuration of the analog and digital inputs and digital outputs as well as Alarm setup and use. Related equipement: ibox and iefis Extender on RS232 bus iefis Extender on CAN bus Page 1

General The G3 infrastructure provides up to 16 general purpose mixed use inputs that can be used either as digital or as analog inputs or both at the same time. Analog inputs provide the ability to measure a voltage in the range of 0 to 16V DC. When used as digital inputs, a voltage level below 1.6V will be taken as off state and any voltage above 1.6V as on state. Up to 8 digital outputs can be used. A digital output is an open collector transistor to ground. Effectively this acts like a switch where one side is connected to ground and the other side is open for use. Note that a maximum DC current limit exists exceeding this may damage the transistor. On a regular iefis (with ibox), inputs 1 to 8 are located on the ibox. On any Lite version of the iefis inputs 1 to 8 are located on the iefis Extender connected to RS232 port 2. Ouputs 1 to 4 are located either on the ibox or iefis extender. On either type of iefis, an iefis extender connected to the CAN bus provides inputs 9 to 16 and outputs 4 to 8. Page 2

The input/output configuration in the setup menu Analog inputs setup Each of the 16 inputs is equivalent in functionality. Page 3

Select one of the 16 analog inputs to view or edit its settings. Here you will find the following entries to edit: Page 4

Page 5

Function Analog inputs may be used for special purposes. Normally select Standard analog channel. Special purposes are described at the end of this section. Name for this input Enter a descriptive name for this input. This is used for example if there is an alarm. You can use up to 11 characters. Highest value for display Should you be using any analog display such as a bargraph in your screen design this value sets the upper limit for the display. It should be the highest value you want to display. Alarm value If you want the top section of the displayed analog indicator to show a different color (normally red) select the value from which the display will be that color. This value is smaller or the same as the highest value for display. Also indicate to the system if you want to use this value by checking the box to the right. You must also check this box if you want to use this limit as alarm even if you are not using any indication on the screen. Caution value You can enable a caution region below the above. This value must be less or equal to the value above. Enable the box to the right if you want the system to use this value. Caution low value You can enable a low caution region above the value below. This value must be more or equal to the value below. Enable the box to the right if you want the system to use this value. Alarm low value If you want the bottom section of the displayed analog indicator to show a different color (normally red) select the value from which the display will be that color. This value is less or the same as the low caution value for display. Also indicate to the system if you want to use this value by checking the box to the right. You must also check this box if you want to use this limit as alarm even if you are not using any indication on the screen. Page 6

Lowest value for display Should you be using any analog display such as a bargraph in your screen design this value sets the lower limit for the display. It should be the lowest value you want to display. Current raw value from ibox This shows the current raw measurement value from the source (either ibox or iefis extender). This value is in the region of 0 to 4095 (12 bit analog to digital conversion where 0 = 0V and 4095 = 16V). Multiply with You can multiply the RAW value above with an integer factor. Then divide After the above multiplication you can apply an integer division. Then add After the multiplication and division you can add an offset. Note that you can enter a negative number so you can also subtract. Use n decimals in final value After the above scaling you can add a decimal point. This will then be used in any numeric display of the value should you add such a display to your screen design. Current scaled value This serves as a check to allow you to verify your scaling. High alarm Here you can enable the high value alarm. You have three options: Alarm disabled, Alarm enabled and Alarm enabled+ibox alarm out. Please also check the high alarm box and select the correct limit if you want to use the high alarm. Low alarm Here you can enable the low value alarm. You have three options: Alarm disabled, Alarm enabled and Alarm enabled+ibox alarm out. Please also check the low alarm box and select the correct limit if you want to use the low alarm. Page 7

Notes on alarm values Alarm limits entered here are always the scaled values. Raw values can only be used if the multiplication and division is 1 and add is 0. The decimal point has no effect and will automatically be taken into account. Example scaling We have a DC current sensor that outputs 2.5V when there is no current flowing. In positive direction the voltage increases by 0.1V for every ampere and in the negative direction the voltage decreases by 0.1 for every ampere. The sensor has a range up to 20A so that means the output voltage will go from 0.5 to 4.5V. We would like a display based on an analog arc with the needle centered and pointing up when current is zero and the needle should move to the right for positive current flow and to the left for negative current flow. At 2.5V the raw reading will be 4096*2.5/16 = 640. At 0.5V the raw reading will be 4096*0.5/16 = 128. So the raw reading will be centered around 640 with a range of (640-128=512) either side. At the maximum reading of 512 we would like the current to show 20.0. This means we need to divide by 25.6. We cannot do that directly as we can only work in whole numbers. So in this case we can simply multiply by 100 and then divide by 256. In this case we will get 200 (512*100/256 = 200). OK, so now we know we need to multiply by 100 and then divide by 256. But this still leaves us with a small problem we want 2.5V to read 0.0. Now at 2.5V we would get 640 * 100 / 256 = 250. So we now simply add -250 to get zero. Now we will get our desired numeric range of -200 to +200. Now all that is left to do is to insert a decimal point. In this case we Use 1 decimal point in final value. After we have done this we can enter suitable values for the display color areas and if we like we can enable alarms (only high alarms as in this case the lower value is also a high alarm just with the current flowing the other direction). Now we can have a look at our screen design, select a analog arc, place it where needed and configure size and position also assign it to the analog input we have chosen. Display of the analog arc using our example above. We also added a text readout (special text item). Page 8

Using the simulator's I/O simulator The iefis screen designer and simulator contains a useful tool that allows you to simulate the analog inputs as well as the outputs. You will find this tool under the Sensor simulation menu in the designer. Here it is used to simulate input number 5 which we used in the previous current example. We have emulated a voltage of 2.9V which results in a value of 4.8A after applying our multiplication, division and add as well as the decimal point. You can also simulate alarm conditions and ensure that the EFIS reports these as intended. Analog inputs other uses Several other EFIS functions can be used with the analog inputs. In particular these: Page 9

Flap position indicator Pitch trim position indicator Roll (bank) trim position indicator These functions are selected in the relevant setups for flaps and trim. Note that these selections can only be used with the first 8 inputs. Special purpose function analog inputs You can select a special purpose to an analog input. If you do this the original function is still fully available so you can continue to use it in parallel to the special function. Alternate AOA system You can apply a DC voltage as source for the AOA functionality in the system. Note that you must also select AOA on analog input in the Instruments setup menu should you want to use this function. This can be used to replace the built in functionality based on the systems pressure sensors with an external system provided it can produce a variable voltage that lies within the input voltage range of the ibox. This can also be used to temporarily construct a test system for the user programmable AOA tone generator. Simply use a variable resistor (potentiometer) to create a variable voltage. Note that AOA sounds will only be produced is a flight is active and there may be minimum and maximum airspeeds applcable. There is also a digital input function that can be used to disable the sound. Note that all scaling functions provided are still functional and must be used. Your task is to set scaling values so the system will derive AOA in steps of 0.1 degrees for a range from 0 to 18 degrees. So your scaling must produce a number from 0 to 180. Example: Assume your alternate AOA sensor gives you a voltage from 3V to 8V to cover the range from 0 to 18 degrees. We arrive at the values: Multiply with 100, divide by 711 and then add -108. This then can be tested in the I/O simulator. At 3V the raw reading will be 4096*3/16 = 768 At 8V the raw reading will be 4096*8/16 = 2048 The range is 2048-768 = 1280. So to get 180 we do 1280/7.111111=180. So to scale this we multiply first with 100 and then divide by 711 (which is the same as divide by 7.11 which is close enough for our purpose). Then we need to get rid of the 3V offset so we subtract 768/7.11111 = 108. Page 10

Digital inputs Digital inputs can be used for a variety of functions. You can use them for a number of built in functions but also for monitoring of external contacts with or without alarm functionality. Page 11

Name Give this input a descriptive name. The system uses this to inform you of the alarm source if this input is enabled for alarms. Active level Select the active level for this input. If set to high then it is considered active when the voltage at the input is at 1.6V or higher. If set to low then the input is considered active if the voltage is below 1.6V. Alarm An alarm is considered active if the input is active and the alarm is enabled. Optionally, you can cause the IBOX alarm output to also be activated. Function 'AP Active NAV/Level'; Engage autopilot on current altitude, current active NAV solution. 'AP Active NAV/VSI'; Current NAV with vertical speed set by rotary control 'AP Turn 180/Level'; Engage current altitude, turn 180 degrees. Page 12

'AP Straight/Level'; Engage the AP on current track and altitude. 'Descent detection'; Disable terrain warning on descent. Enable this in the terrain setup menu. 'Transponder squat switch'; Transponder squat switch for use with mode-s (Select this mode of operation in the transponder setup menu). 'Remote menu activate'; Remote menu controls 'Remote menu select'; 'Remote menu Down'; 'Remote menu Up'; 'Transponder Ident'; Activate the transponder ident 'Stopwatch start/stop'; Start or stop the stop watch 'Stopwatch reset'; Reset the stop watch (set to zero) 'Down count start/stop'; Start or stop the down count timer 'Alarm acknowledge'; Acknowledge active alarms 'Flight active detect'; External flight active detection (if allowed in operations setup) 'Vario tone switch'; Switch vario tone on/off 'AOA tone switch'; Switch the user programmable AOA tone generator on/off 'No function'; - input has no built in function Notes: If autopilot engage function, if autopilot is engaged, selecting function will disengage the autopilot. Page 13

Digital outputs Outputs are open collector transistors which provide a current path to ground when on. You can view these as a switch. When the switch is on and you have (for example) a lamp connected to 12V, the lamp will illuminate. Digital outputs can be switched from a variety of sources and you can also create touchable fields on the display to switch outputs on, off or toggle the output state. The choices to switch outputs are: 'Not used' = select this if you want a touch field to switch the output. 'Flight Active' 'Any alarm active' 'Any Engine alarm' 'Any Fuel alarm' 'Any Electrics active' 'Any Flight alarm' 'Any analog input alarm', 'Any digital input alarm' 'Analog input 1 alarm' 'Analog input 2 alarm' 'Analog input 3 alarm' 'Analog input 4 alarm', 'Digital input 1 alarm', 'Digital input 2 alarm' 'Digital input 3 alarm' 'Digital input 4 alarm' Page 14

Basic example of a screen design including 8 touch fields connected to digital outputs. You use the touch field component, set it to an output function (ON, OFF or TOGGLE) and then select visual and give it desired colors for the ON and OFF states. You can also just show them as states in which case touching them will not change their state. Gray color means that the assigned output is not available (for example it has been assigned to the CAN based iefis extender but this is not connected). Page 15

Cautions Please do not use digital outputs to control safety critical items on the aircraft. These outputs may only be used where failure of such output will not cause degradation of flight safety in any way. Input circuit The input appears as a 12.2Kohm resistor to ground. With nothing connected, the input will thus be pulled to ground potential (0V). This makes it very simple to connect items like switches simply wire a switch to 12 or 24V volts. Closing the switch then pulls the input high. Ensure that any devices that produce a voltage to be measured is able to drive a 12.2Kohm load. Output circuit The output consists of a open collector darlington transistor to ground. The transistor is on when the output is on. The transistor can be used to switch up to 500mA DC. For higher currents, please use a relay. Note: Darlington transistors will show a residual output voltage of around 0.6V they cannot switch lower than this. This is not normally an issue but please be aware of this when you measure the output with a volt meter and a load connected. Note: If a relay or any other inductive load is switched, you MUST fit a reversed biased diode over the coil. A typical choice is the 1N4007. Failure to do this may lead to destruction of the output transistor due to the back-emf of the coil as it is switched off. Page 16