E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Similar documents
Model Number Structure

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Accessories (Order Separately)

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

Photoelectric Sensors E3F2

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Absolute Rotary Encoder E6CP

Model Number Structure

EZ-LIGHT K30L Series With Independent Push Button Contact

EZ-LIGHT K90FDL Daylight Visible

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Multifunction Digital Timer

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

WLS27 Multicolor LED Strip Light with EZ-STATUS

Type Contact form Model

Photoelectrics Through-beam Type PA18C.T..., DC

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

GC61 Digital Pressure Gauge. Operation Manual

True RMS AC/DC Mini Clamp Meter

Self--powered Time Counter

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

User s Manual. Model Digital Sound Level Meter

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

Cylindrical Photoelectric Sensor CY-100 SERIES

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

WLC60 Heavy Duty LED Light - PWM Dimmable

Operating Instructions

LED Series Sealed Backlights

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

3M Sensored Termination (15 kv) QX-T15I-vi1-E

AGS Low profile capacitive air gap measuring sensor for rotating machines

Hybrid Chart Recorder 250 mm (10")

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

GC30 Digital Differential Pressure Gauge Operation Manual

Electronic M.O.P Card. Instruction Manual Model D

Electrical connection

Linear Array with Intensity Adjustment

Digital Flow Switch for Large Flow

KHT 1000C HV-Probe Calibrator. Instruction Manual

E6F-A. Rugged Encoder for High-precision Detection of Automatic Machine Timing. Absolute 60-mm-dia. Rotary Encoder. Ordering Information.

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Electrical connection

Q3X Laser Contrast Sensor

Installation Manual SaVi Note Underwater LED Light

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

EZ-LIGHT S18L Color General-Purpose Indicators

Warner Photoscanner MCS-500 Series LED Photoelectric Control

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

American Power Design, Inc.

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

3G/HD/SD-SDI to HDMI Converter

Cat. No. O008-E1-04 USER S MANUAL. 3F88L-160/162 Cam Positioner

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Features. Typical Applications

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

1X4 HDMI Splitter with 3D Support

ST-4000D SIGNAL LEVEL METER

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Separate Thin Amplifier type. AP-V40AW Series

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

02/11/2015

USB-TG124A Tracking Generator User Manual

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Transcription:

Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting space. Easy-to-read red LED indicator. Analog current output models available (-A@Y). port Rc (PT) 1/8 models available (-R). EN and UL approved. Ordering range * Digital output Linear output Model 0 to 200 Pa -AR2C 0 to 500 Pa -AR5C --- 0 to 2.00 kpa -A2C 0 to 5.00 kpa NPN open collector -A5C 0 to 200 Pa -AR2Y 0 to 2.00 kpa 4 to 20 ma -A2Y 0 to 5.00 kpa -A5Y 0 to 5.00 kpa PNP open collector -A5B Note: Order the optional E89-Y1 Panel-mounting Bracket. A model number ending in -R indicates the is die-cast for Rc (PT) 1/8 models. Accessories (Order Separately) Panel Attachment Parts Set (For @36 and @45 Models) E89-Y1 * Model * Includes the cover, guide, frame, and holder. -@-F@ 1138

Ratings Item Power supply voltage Model -AR2C -AR5C * The -A5B provides a PNP open-collector (NO/NC) output. -A2C -A2C-R 12 to 24 VDC ±10% with a ripple (p-p) of 10% max. -A5B -A5C -A5C-R -AR2Y Current consumption 50 ma max. 75 ma max. type Differential pressure -A2Y -A2Y-R -A5Y -A5Y-R Rated pressure range 0 to 200 Pa 0 to 500 Pa 0 to 2.00 kpa 0 to 5.00 kpa 0 to 200 Pa 0 to 2.00 kpa 0 to 5.00 kpa Withstand pressure 5 kpa 50 kpa 5 kpa 5 kpa Applicable fluid Non-corrosive gas and non-flammable gas Output current --- --- --- --- 4 to 20 ma Linear output Digital output Permissible load resistance --- --- ---- --- 0 to 250 Ω Precision --- --- --- --- ±2.5%FS ±1.0%FS Linearity --- --- --- --- ±2.5%FS ±1.0%FS Output form NPN open collector (NO/NC) * Load current Output applied voltage Residual voltage 100 ma VDC max. 1.0 V max. with a load current of 100 ma or 0.4 V max. with a load current of 16 ma Repeat accuracy ±2.5%FS ±1.0%FS ±2.5%FS ±1.0%FS 3-digit 7-segment red LED Indicator lamp Response speed accuracy Orange LED indicator (OUT1: lit when digital output is ON) Orange LED indicator (OUT2: lit when digital output is ON) 0.5 s max. ±1.0%FS Setting resolution 1 Pa 0.01 kpa 1 Pa 0.01 kpa Protection circuits Ambient temperature Ambient humidity Storage temperature 25 to 65 C Accessories Reverse polarity protection, load short-circuit protection Operating: 10 to 55 C (with no icing) Operating: 25% to 85% (with no condensation) Mounting Brackets (A and B), Instruction manual Specifications Temperature influence Humidity influence Degree of protection Dielectric strength Insulation resistance Vibration resistance Shock resistance port Cable Weight -A2C/A5C: ±3%FS max. -AR5C: ±6%FS max. -AR2C: ±10%FS max. -A2C/A5C: ±3%FS max. -AR5C: ±6%FS max. -AR2C: ±10%FS max. IP40 (IEC) 1,000 VAC at 50/60 Hz for 1 minute 100 MΩ min. (at 500 VDC) between current-carrying parts and case Destruction: 10 to 150 Hz, 0.75-mm single amplitude or 100 m/s 2, 4 times each for 8 min in X, Y and Z directions Destruction: 0 m/s 2 3 times each in X, Y and Z directions 4.5-dia resin pipe or Rc (PT) 1/8 taper screw (-R type) Vinyl-insulated round cable 4 dia., Standard length: 2 m Approx. 80 g -@-F@ 1139

Nomenclature (3) (4) (5) (6) (7) (1) (2) (1) Numerical value/menu indication s the measured pressure and some menu settings. (2) Unit Shows the measuring unit. Unit currently in use is illuminated. (3) OUT 1 indication LED In measurement mode, it lights when OUT 1 output is on. In setting mode, it flashes when OUT 1 is being set. (4) OUT 2 indication LED In measurement mode, it lights when OUT 2 output is on. In setting mode, it flashes when OUT 2 is being set. Operation Key (5) ADJ In measurement mode, it adjusts the Zero Point. In setting mode, it shifts to measurement mode. (6) MODE In measurement mode, it shifts to setting mode and selects the current setting or menu option. (7) UP/DOWN In measurement mode, pushing the DOWN key displays the ON and OFF points of OUT 1; pushing the UP key displays the ON and OFF points of OUT 2. In setting mode, the UP and DOWN keys increase or decrease the numeric value, respectively, or scroll through the menu options. Dimensions (Unit: mm) Standard Port Type ( Port: 4.5 dia.) -AR5C 31 -AR2C -A2C -A5C -A5B -AR2Y -A2Y 5 -A5Y (39.8) 29.8±0.6 18 10 4.5-dia. Four, M3 Thread depth: 5.2 (hole depth 8.2) Mounting Holes 4.5-dia. Note: Make sure that the tightening torque does not exceed 0.54 N m. 15 4-dia. vinyl-insulated round cable with 4conductors (18/0.12 dia.) (Analog Output Models: 5 conductors), Standard length: 2 m CAD data -@-F@ Die-case Port Type ( port: Rc(PT)1/8) -A2C-R -A5C-R 31 -A2Y-R -A5Y-R 5 (39.8) 29.8±0.6 18 10 Rc(PT)1/8 Four, M3 Thread depth: 5.2 (Hole depth: 8.2) Mounting Holes Rc(PT)1/8 Note: Make sure that the tightening torque does not exceed 0.54 N m. 17 4-dia. vinyl-insulated round cable with four conductors (18/0.12 dia.) (Analog Output Model: 5 conductors), Standard length: 2 m 1140

Accessories (Provided) Mounting Bracket A Mounting Bracket B 15 Two,3.7 dia. 19.6 15.6 13 4.2 1.8 25 35 19 24 4.2 dia. 13 4.2 1.8 25 35 11.4 16.4 4.2 dia. 26 Refer to the Sensor Datasheet (Cat. No. F045) for details. -@-F@ Cat. No. F833-E1-01 In the interest of product improvement, specifications are subject to change without notice. 1141

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2013.12 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2013 All Right Reserved.