Test Report Product Name: Access Point Model No.: MS-6809 FCC ID: DoC Applicant : MICRO-STAR INT L Co., LTD Address : No 69, Li-De st., Jung-He City, Taipei Hsien, Taiwan, R.O.C Date of Receipt : June 10, 2003 Date of Test : June 13, 2003 Report No. : 036L117F The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government Page: 1 of 23
DECLARATION OF CONFORMITY Per FCC Part 2 Section 2. 1077(a) The following equipment: Product Name : Access Point Trade Name : MICRO-STAR Model Number : MS-6809 It s herewith confirmed to comply with the requirements of FCC Part 15 Rules.(Class B) Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The result of electromagnetic emission has been evaluated by QuieTek EMC laboratory (NVLAP Lab. Code : 200347-0 ) and showed in the test report. ( Report No. : QTK-036L117F ) It is understood that each unit marketed is identical to the device as tested, and Any changes to the device that could adversely affect the emission Characteristics will require retest. The following importer / manufacturer is responsible for this declaration: Company Name Company Address Telephone Facsimile : Person is responsible for marking this declaration: Name ( Full name ) Position / Title Date Legal Signature
Test Report Certification Test Date : June 13, 2003 Report No. : 036L117F Product Name : Access Point Applicant : MICRO-STAR INT L Co., LTD Address : No 69, Li-De st., Jung-He City, Taipei Hsien, Taiwan, R.O.C Manufacturer : MICRO-STAR INT L Co., LTD Model No. : MS-6809 FCC ID. : DoC Accredited by NIST (NVLAP) NVLAP Lab Code: 200347-0 Rated Voltage : AC 120V/60Hz Trade Name : MICRO-STAR Measurement Standard : FCC Part 15 Subpart B Measurement Procedure : ANSI C63.4: 1992 Test Result : Complied The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. This report must not be used to claim product endorsement by NVLAP any agency of the U.S. Government Documented By : ( Cordelia Huang ) Tested By : (John Wu ) Approved By : ( Gene Chang ) Page: 2 of 23
Description TABLE OF CONTENTS Page 1. GENERAL INFORMATION...4 1.1. EUT Description...4 1.2. Tested System Details...5 1.3. Configuration of tested System...6 1.4. EUT Exercise Software...6 1.5. Test Facility...7 2. Conducted Emission...8 2.1. Test Equipment...8 2.2. Test Setup...8 2.3. Limits...8 2.4. Test Procedure...9 2.5. Test Result of Conducted Emission...10 3. Radiated Emission...12 3.1. Test Equipment...12 3.2. Test Setup...12 3.3. Limits...13 3.4. Test Procedure...13 3.5. Test Result of Radiated Emission...14 4. EMI Reduction Method During Compliance Testing...20 Attachment 1: EUT Test Photographs Attachment 2: EUT Detailed Photographs Reference : Laboratory of License Page: 3 of 23
1. GENERAL INFORMATION 1.1. EUT Description Product Name : Access Point Trade Name : MICRO-STAR FCC ID. : DoC Model No. : MS-6809 Frequency Range : 2412MHz to 2462MHz Channel Number : 11 Chip Rate : 1Mbps, 2Mbps, 5.5Mbps, 11Mbps Type of Modulation : Direct Sequence Spread Spectrum Antenna type : Dipole;Patch Antenna Gain : 2.5dBi;2dBi Operator Selection of : By software Operating Frequency Power Adapter : DVE, M/N: DV-1250 Cable In: AC 120V/60Hz/12W Cable Out: DC 12V/500mA UNE OUT:2m Frequency of Each Channel: Channel Frequency Channel Frequency Channel Frequency Channel 1: 2412 MHz Channel 5: 2432 MHz Channel 9: 2452 MHz Channel 2: 2417 MHz Channel 6: 2437 MHz Channel 10: 2457 MHz Channel 3: 2422 MHz Channel 7: 2442 MHz Channel 11: 2462 MHz Channel 4: 2427 MHz Channel 8: 2447 MHz Note: 1. This device is a 2.4GHz Access Point included a 2.4GHz receiving function, a 2.4GHz transmitting function. 2. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15 Subpart B for 2.4GHz Receiver 3. Regards to the frequent band operation; three channels were selected to perform the test, then shown on this report. 4. This device is a composite device in accordance with Part 15 regulations. The function for the 2.4GHz transmitting was measured and made a test report that the report number is 036L117FI, certified under FCC ID: I4L-MS6809 EMI Mode Mode 1: Normal Operation Page: 4 of 23
1.2. Tested System Details The types for all equipment, plus descriptions of all cables used in the tested system (including inserted cards) are: Product Manufacturer Model No. Serial No. Power Cord (1) Notebook PC ASUS S1300 26NP018680 Non-shielded,1.8m (2) Notebook PC ASUS S1300 24NP035390 Non-shielded,1.8m Signal Cable Type Signal cable Description A. LAN Cable Non-shielded, 3.0m Page: 5 of 23
1.3. Configuration of tested System A EUT Notebook PC (1) Notebook PC (2) 1.4. EUT Exercise Software (1) Setup the EUT and simulators as shown on 1.3 (2) Turn on the power of all equipment. (3) Notebook PC reads data from disk. (4) Data will be receiving through EUT. (5) The receive status will be shown on the monitor. (6) Repeat the above procedure 1.4.2 to 1.4.4 Page: 6 of 23
1.5. Test Facility Ambient conditions in the laboratory: Items Required (IEC 68-1) Actual Temperature ( C) 15-35 20-35 Humidity (%RH) 25-75 50-65 Barometric pressure (mbar) 860-1060 950-1000 Site Description: Site Name: Site Address: November 3, 1998 File on Federal Communications Commission FCC Engineering Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Reference 31040/SIT1300F2 August 30, 2001 Accreditation on NVLAP NVLAP Lab Code: 200347-0 Quietek Corporation No.75-1, Wang-Yeh Valley, Yung-Hsing, Chiung-Lin, Hsin-Chu County, Taiwan, R.O.C. TEL : 886-3-592-8858 / FAX : 886-3-592-8859 E-Mail: service@quietek.com Page: 7 of 23
2. Conducted Emission 2.1. Test Equipment The following test equipment are used during the conducted emission test: Item Instrument Manufacturer Type No./Serial No Last Cal. Remark 1 Test Receiver R & S ESCS 30/825442/17 May, 2003 2 L.I.S.N. R & S ESH3-Z5/825016/6 May, 2003 EUT 3 L.I.S.N. Kyoritsu KNW-407/8-1420-3 May, 2003 Peripherals 4 Pulse Limiter R & S ESH3-Z2 N/A 5 No.2 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 2.2. Test Setup Reference Plane Test Receiver 40cm 12dBuV Load EUT LISN LISN Ground Plane LISN 2.3. Limits FCC Part 15 Subpart B Paragraph 15.107 (dbuv) Limit Frequency Limits MHz QP AV 0.15-0.50 66-56 56-46 0.50-5.0 56 46 5.0-30 60 50 Remarks : In the above table, the tighter limit applies at the band edges. Page: 8 of 23
2.4. Test Procedure The EUT and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test setup and photographs.) Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ANSI C63.4:1992 on conducted measurement. Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using a receiver bandwidth of 9kHz. Page: 9 of 23
2.5. Test Result of Conducted Emission Product : Access Point Test Item : Conducted Emission Power Line : Line 1 Test Mode : Mode 1: Normal Operation Frequency Cable Probe Reading Emission Limits Loss Factor Level Level MHz db db dbuv dbuv dbuv =================================================================== Quasi-Peak * 0.222 0.21 0.10 43.99 44.30 62.76 0.279 0.21 0.10 40.36 40.67 60.85 0.559 0.21 0.10 36.03 36.34 56.00 1.006 0.21 0.10 27.15 27.46 56.00 11.896 0.29 0.26 24.70 25.25 60.00 23.129 0.26 0.50 21.03 21.79 60.00 Average * 0.222 0.21 0.10 24.70 25.01 52.76 0.279 0.21 0.10 20.20 20.51 50.85 0.559 0.21 0.10 16.00 16.31 46.00 1.006 0.21 0.10 15.10 15.41 46.00 11.896 0.29 0.26 19.20 19.75 50.00 23.129 0.26 0.50 16.90 17.66 50.00 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. *, means this data is the worst emission level. 3. Emission Level = Reading Level + LISN Factor + Cable Loss. Page: 10 of 23
Product : Access Point Test Item : Conducted Emission Power Line : Line 2 Test Mode : Mode 1: Normal Operation Frequency Cable Probe Reading Emission Limits Loss Factor Level Level MHz db db dbuv dbuv dbuv Quasi-Peak * 0.169 0.21 0.10 46.04 46.35 65.02 0.281 0.21 0.10 40.02 40.33 60.79 0.558 0.21 0.10 36.63 36.94 56.00 1.118 0.21 0.10 26.71 27.03 56.00 1.675 0.23 0.12 18.15 18.50 56.00 11.896 0.29 0.26 23.88 24.43 60.00 Average * 0.169 0.21 0.10 32.40 32.71 55.02 0.281 0.21 0.10 22.20 22.51 50.79 0.558 0.21 0.10 17.70 18.01 46.00 1.115 0.21 0.10 12.70 13.02 46.00 1.675 0.23 0.12 9.70 10.05 46.00 11.896 0.29 0.26 21.30 21.85 50.00 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. *, means this data is the worst emission level. 3. Emission Level = Reading Level + LISN Factor + Cable Loss. Page: 11 of 23
3. Radiated Emission 3.1. Test Equipment The following test equipment are used during the radiated emission test: Test Site Equipment Manufacturer Model No./Serial No. Last Cal. Site # 1 Site # 2 Note: X Test Receiver R & S ESCS 30 / 825442/14 May, 2003 X Spectrum Analyzer Advantest R3261C / 71720140 May, 2003 X Pre-Amplifier HP 8447D/3307A01812 May, 2003 X Bilog Antenna Chase CBL6112B / 12452 Sep., 2001 X Horn Antenna EM EM6917 / 103325 May, 2003 Test Receiver R & S ESCS 30 / 825442/17 May, 2003 Spectrum Analyzer Advantest R3261C / 71720609 May, 2003 Pre-Amplifier HP 8447D/3307A01814 May, 2003 Bilog Antenna Chase CBL6112B / 2455 Sep., 2001 Horn Antenna EM EM6917 / 103325 May, 2003 1. All equipments that need to calibrate are with calibration period of 1 year. 2. Mark X test instruments are used to measure the final test results. 3.2. Test Setup 3m FRP Dome 1m to 4m Non-Conducted Table EUT The height of board band or Dipole Antenna was scanned from 1M to 4M. The distance between antenna and turn table was 3M regards to the standard adopted. 80cm Test Receiver Fully soldered Metal Ground To Controller To Receiver Page: 12 of 23
3.3. Limits FCC Part 15 Subpart B Paragraph 15.109 Limits Frequency MHz uv/m @3m dbuv/m@3m 30-88 100 40 88-216 150 43.5 216-960 200 46 Remarks : Above 960 500 54 1. RF Voltage (dbuv) = 20 log RF Voltage (uv) 2. In the Above Table, the tighter limit applies at the band edges. 3. Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the device or system. 3.4. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT was positioned such that the distance from antenna to the EUT was 3 meters. The antenna can move up and down between 1 meter and 4 meters to find out the maximum emission level. Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the maximum emission, all of the interface cables must be manipulated according to ANSI C63.4:1992 on radiated measurement. The bandwidth below 1GHz setting on the field strength meter (R&S Test Receiver ESCS 30) is 120 khz and above 1GHz is 1MHz. Page: 13 of 23
3.5. Test Result of Radiated Emission Product : Access Point Test Item : General Radiated Emission Test Site : No.1 OATS Test Mode : Mode 1: Normal Operation (Channel 1) Frequency Cable Probe PreAMP Reading Emission Margin Limit Loss Factor Level Level MHz db db/m db dbuv dbuv/m db dbuv/m ============================================================= Horizontal: 62.487 1.03 5.45 0.00 22.99 29.47 10.53 40.00 126.859 1.37 11.57 0.00 17.63 30.57 12.93 43.50 245.268 1.98 11.16 0.00 16.08 29.22 16.78 46.00 347.198 2.50 12.92 0.00 24.06 39.49 6.51 46.00 435.466 2.96 15.65 0.00 19.19 37.80 8.20 46.00 523.738 3.42 16.44 0.00 18.33 38.19 7.81 46.00 * 611.031 3.87 18.42 0.00 19.14 41.43 4.57 46.00 787.574 4.77 19.21 0.00 14.77 38.75 7.25 46.00 963.144 5.67 20.15 0.00 17.06 42.88 11.12 54.00 Vertical: 62.359 1.03 5.58 0.00 20.97 27.59 12.41 40.00 128.597 1.38 10.53 0.00 18.67 30.58 12.92 43.50 245.286 1.98 11.40 0.00 15.73 29.11 16.89 46.00 * 347.198 2.50 13.15 0.00 24.85 40.50 5.50 46.00 435.462 2.96 17.09 0.00 17.44 37.49 8.51 46.00 523.738 3.42 16.79 0.00 17.73 37.94 8.06 46.00 611.284 3.87 19.42 0.00 13.93 37.22 8.78 46.00 787.578 4.77 19.66 0.00 11.23 35.66 10.34 46.00 963.487 5.67 20.24 0.00 11.31 37.22 16.78 54.00 Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. *, means this data is the worst emission level. 3. Emission Level = Reading Level + Probe Factor + Cable Loss. Page: 14 of 23
Product : Access Point Test Item : General Radiated Emission Test Site : No.1 OATS Test Mode : Mode 1: Normal Operation (Channel 6) Frequency Cable Probe PreAMP Reading Emission Margin Limit Loss Factor Level Level MHz db db/m db dbuv dbuv/m db dbuv/m ============================================================= Horizontal: 56.260 1.00 5.93 0.00 23.68 30.62 9.38 40.00 122.930 1.35 11.73 0.00 19.40 32.48 11.02 43.50 216.547 1.83 8.15 0.00 24.54 34.52 11.48 46.00 334.527 2.44 12.56 0.00 22.91 37.91 8.09 46.00 521.649 3.40 16.52 0.00 17.67 37.58 8.42 46.00 734.861 4.50 18.70 0.00 15.14 38.34 7.66 46.00 * 953.257 5.62 20.00 0.00 15.05 40.67 5.33 46.00 Vertical: 48.627 0.96 7.00 0.00 22.16 30.13 9.87 40.00 126.917 1.37 10.47 0.00 19.78 31.62 11.88 43.50 213.681 1.81 9.10 0.00 22.70 33.62 9.88 43.50 421.599 2.89 17.60 0.00 16.32 36.81 9.19 46.00 615.537 3.89 19.34 0.00 14.59 37.82 8.18 46.00 826.175 4.98 18.81 0.00 12.64 36.42 9.58 46.00 * 921.531 5.47 21.39 0.00 16.05 42.91 3.09 46.00 Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. *, means this data is the worst emission level. 3. Emission Level = Reading Level + Probe Factor + Cable Loss. Page: 15 of 23
Product : Access Point Test Item : General Radiated Emission Test Site : No.1 OATS Test Mode : Mode 1: Normal Operation (Channel 11) Frequency Cable Probe PreAMP Reading Emission Margin Limit Loss Factor Level Level MHz db db/m db dbuv dbuv/m db dbuv/m ============================================================= Horizontal: 62.951 1.04 5.65 0.00 23.15 29.84 10.16 40.00 134.658 1.41 11.59 0.00 17.58 30.58 12.92 43.50 226.517 1.88 9.08 0.00 19.93 30.89 15.11 46.00 348.658 2.51 13.15 0.00 20.15 35.81 10.19 46.00 537.917 3.48 17.05 0.00 18.08 38.61 7.39 46.00 * 846.000 5.07 19.67 0.00 14.75 39.48 6.52 46.00 Vertical: 52.170 0.98 6.39 0.00 23.10 30.48 9.52 40.00 128.921 1.38 10.53 0.00 21.68 33.59 9.91 43.50 214.853 1.82 9.30 0.00 25.35 36.47 7.03 43.50 318.325 2.36 12.51 0.00 20.14 35.00 11.00 46.00 512.964 3.36 16.67 0.00 17.77 37.81 8.19 46.00 735.000 4.50 20.62 0.00 11.39 36.51 9.49 46.00 * 948.634 5.60 20.70 0.00 14.28 40.58 5.42 46.00 Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. *, means this data is the worst emission level. 3. Emission Level = Reading Level + Probe Factor + Cable Loss. Page: 16 of 23
Product : Access Point Test Item : General Radiated Emission Test Site : No.1 OATS Test Mode : Channel 1 Frequency Cable Probe PreAMP Reading Emission Margin Limit Loss Factor Level Level MHz db db/m db dbuv dbuv/m db dbuv/m ============================================================= Horizontal Peak Detector: 2037.648 2.05 26.02 19.95 44.17 52.29 21.71 74.00 4074.108 3.00 29.85 19.90 40.20 53.16 20.84 74.00 * 6111.460 3.91 33.12 20.52 37.06 53.57 20.43 74.00 Average Detector: -- Vertical Peak Detector: 2037.648 2.05 26.02 19.95 44.12 52.24 21.76 74.00 4074.702 3.00 29.85 19.90 39.38 52.34 21.66 74.00 * 6111.460 3.91 33.12 20.52 36.80 53.31 20.69 74.00 Average Detector: -- Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. Emission Level = Reading Level + Probe Factor + Cable Loss PreAMP. 3. The average measurement was not performed when the peak measured data under the limit of average detection. If the readings given are average, peak measurement should also be supplied. Page: 17 of 23
Product : Access Point Test Item : General Radiated Emission Test Site : No.1 OATS Test Mode : Channel 6 Frequency Cable Probe PreAMP Reading Emission Margin Limit Loss Factor Level Level MHz db db/m db dbuv dbuv/m db dbuv/m ============================================================= Horizontal Peak Detector: 2062.148 2.18 26.07 19.94 44.02 52.34 21.66 74.00 4124.297 3.01 29.94 19.91 40.24 53.28 20.72 74.00 * 6186.148 3.93 33.30 20.63 37.07 53.67 20.33 74.00 Average Detector: -- Vertical Peak Detector: 2062.445 2.18 26.07 19.94 44.05 52.37 21.63 74.00 4124.297 3.01 29.94 19.91 40.25 53.29 20.71 74.00 * 6186.445 3.93 33.30 20.63 36.91 53.51 20.49 74.00 Average Detector: -- Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. Emission Level = Reading Level + Probe Factor + Cable Loss PreAMP. 3. The average measurement was not performed when the peak measured data under the limit of average detection. If the readings given are average, peak measurement should also be supplied. Page: 18 of 23
Product : Access Point Test Item : General Radiated Emission Test Site : No.1 OATS Test Mode : Channel 11 Frequency Cable Probe PreAMP Reading Emission Margin Limit Loss Factor Level Level MHz db db/m db dbuv dbuv/m db dbuv/m ============================================================= Horizontal Peak Detector: 2087.445 2.25 26.19 19.93 43.80 52.31 21.69 74.00 4174.891 3.02 30.04 19.93 40.25 53.38 20.62 74.00 * 6261.148 3.94 33.49 20.74 36.93 53.62 20.38 74.00 Average Detector: -- Vertical Peak Detector: 2087.468 2.25 26.19 19.93 43.73 52.24 21.76 74.00 4174.297 3.02 30.04 19.93 40.23 53.36 20.64 74.00 * 6261.743 3.95 33.53 20.74 36.79 53.53 20.47 74.00 Average Detector: -- Note: 1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average measurements as necessary. 2. Emission Level = Reading Level + Probe Factor + Cable Loss PreAMP. 3. The average measurement was not performed when the peak measured data under the limit of average detection. If the readings given are average, peak measurement should also be supplied. Page: 19 of 23
4. EMI Reduction Method During Compliance Testing No modification was made during testing. Page: 20 of 23
Attachment 1: EUT Test Photographs Page: 21 of 23
Report No.: 036L117F Attachment 1: EUT Test Setup Photographs Front View of Conducted Test Back View of Conducted Test Page : 1 of 3
Report No.: 036L117F Front View of Radiated Test Back View of Radiated Test Page : 2 of 3
Report No.: 036L117F Front View of High Frequency Radiated Test Back View of High Frequency Radiated Test Page : 3 of 3
Attachment 2: EUT Detailed Photographs Page: 22 of 23
Report No.: 036L117F Attachment 2 : EUT Detailed Photographs (1) EUT Photo (2) EUT Photo Page : 1 of 8
Report No.: 036L117F (3) EUT Photo (4) EUT Photo Page : 2 of 8
Report No.: 036L117F (5) EUT Photo (6) EUT Photo Page : 3 of 8
Report No.: 036L117F (7) EUT Photo (8) EUT Photo Page : 4 of 8
Report No.: 036L117F (9) EUT Photo (10) EUT Photo Page : 5 of 8
Report No.: 036L117F (11) EUT Photo (12) EUT Photo Page : 6 of 8
Report No.: 036L117F (13) EUT Photo (14) EUT Photo Page : 7 of 8
Report No.: 036L117F (15) EUT Photo (16) EUT Photo Page : 8 of 8
Reference : Laboratory of License Page: 23 of 23