CMS Tracker Optical Control Link Specification. Part 1: System

Similar documents
Digital Control Links Status and Plans

F. Vasey, G. Cervelli, K. Gill, R. Grabit, M. Hedberg, F. Jensen, A. Zanet. CERN, 1211 Geneva 23, Switzerland

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

40GBd QSFP+ SR4 Transceiver

LONWORKS Fibre Optic Converter

RX40_V1_0 Measurement Report F.Faccio

Product Specification. RoHS-6 Compliant 10Gb/s 10km XFP Optical Transceiver FTLX1412M3BCL

1310nm Video SFP Optical Transceiver

Fibre Optic Modem ODW-622

10Gbps SFP+ Optical Transceiver, 10km Reach

100G QSFP28 SR4 Transceiver

ODW-621. RS-232 Point-to-point applications

Product Specification 40BASE-SR4 100m QSFP+ Gen2 Optical Transceiver Module FTL410QE2C

XFP-1020-WA/B 10Gbps XFP Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

Intel Ethernet SFP+ Optics

1310nm Single Channel Optical Transmitter

Fibre Optic Modem ODW-611

10G- XFP- SR- AO. 10Gbs XFP Transceiver

The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting postamplifier

GIGALIGHT 300m XFP Optical Transceiver GX SRC

LONWORKS Fibre Optic Router

XFP 10G 850nm 300M SR SLXF-1085-SR

Fibre optic router for TP/FT-10 LRW-112PP

Product Specification 40BASE-SR4 QSFP+ Gen3 Optical Transceiver Module FTL410QE3C

Product Specification 56Gbps 60/100m QSFP+ Optical Transceiver Module FTL414QB2C APPLICATIONS

CMS Tracker Synchronization

SNS-XFP-10GD-LR 10 Gbps Multi-Rate XFP Transceivers OC192/STM-64, 10GE or 10G FC 1310nm, Single-Mode 10Km, with Digital Diagnostics.

10G BiDi XFP 10km Optical Transceiver GBX-xxxx192-LRC

Product Specification. 10Gb/s, 10km XFP Optical Transceiver FTLX1413M3BCL

Product Specification XFP 10G LR 20km LC Optical Transceiver

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS. Logic Symbol Name/Description Note 1 - GND Module Ground 1

XFP Optical Transceiver

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

10Gb/s SFP+ Optical Transceiver Module 10GBASE-LR/LW

FX-1310-F10 10Gbps XFP Optical Transceiver, 10km Reach

QSFP+ 40GBASE-SR4 Fiber Transceiver

XFP Bi-Directional 10G 20Km 1270/1330nmTx / 1330/1270nmRx SLXFB-XXXX-20

10G- XFP- LR- AO. 10Gbs XFP Transceiver

10Gbps 10km Range SFP+ Optical Transceiver

1550 nm TX / 1310 nm RX / 3 Gb/s Medium Power 1-Fibre SM Video SFP Transceiver

CWDM / 12 Gb/s Medium Power SM Video Digital Diagnostic SFP+ Transceiver

Ethernet Media Converters

T A S A 2 N B 1 F A H

FOM-9010, FOM-9011 and FOM-9012

40G SWDM4 MSA Technical Specifications Optical Specifications

CWDM / 3 Gb/s Medium Power SM Video Digital Diagnostic SFP Transceiver

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

CWDM / 3 Gb/s Medium Power Optical SM Digital Diagnostic Transmitter/Receiver FVD2-1TR-SM30-XX

DATA SHEET. Two (2) fibers Detachable DisplayPort 1.2 Extender, DPFX-200-TR

DATA SHEET. Two (2) fibers Detachable HDMI 2.0 Extender,

EOLQ-851HG-02-MO Series Multi-Mode 100GBASE-SR4 QSFP28 Transceiver RoHS6 Compliant

Power (dbm) λ (nm) LINK DISTANCE SDI Bit Rate Max. Link Distance (km) 3G-SDI 2.97Gbps 30 HD-SDI 1.485Gbps 30 SD-SDI 270Mbps 30

6ch LC duplex QSFP Receiver ROSA (4ch x 6Gbps) + μ-bosa (2.5Gbps) (2km) FVQ2-4R1B-SM2

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

DATA SHEET. One (1) fiber Detachable HDMI Extender, HDFX-200-TR

40G SWDM4 MSA Technical Specifications Optical Specifications

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

GFT Channel Digital Delay Generator

Parameter Symbol Min. Typ. Max. Unit. Supply Voltage Vcc V. Input Voltage Vin -0.3 Vcc+0.3 V. Storage Temperature Tst C

Ordering information. 40Gb/s QSFP+ ER4 Optical Transceiver Product Specification. Features

Final Results of the Industrial Production of CMS Tracker Analog Optohybrids. M.Friedl, M.Pernicka

10Gb/s XFP Optical Transceiver Module

QSFP-100G-LR4-AR-LEG. 100Gbase-LR4 QSFP28 Transceiver

Part No. Data Rate Distance Interface Temp. DDMI MMF OM3 for 70m QSFP28.100G.SR Gbps

10Gb/s 40km DWDM XFP Optical Transceiver

FTS-S12G-B53Y-005. SFP 1000Base-LX, BiDi, 1550/1310nm, single-mode, 5km

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

QSFP28 Series Preliminary. EOLQ-161HG-20-LA2 Series. Features. Applications. Ordering Information

3G-SDI Video SFP CWDM nm 40km Optical Transceivers

FTS-M12G-S85L-55M. SFP 1000Base-SX, 850nm, multi-mode, 550m

1550 nm / 3 Gb/s Medium Power Single Optical SM Digital Diagnostic Transmitter FVD2-1TR-SM50

AddOn Computer s SFP transceivers are RoHS compliant and lead- free.

FTX-S1XG-S55L-040DI. XFP 10GBase-ER, 1550nm, single-mode, 40km

EPON ONU Triplexer Transceiver

SHQP28-100G-LR4-B. 103/112Gb/s QSFP28 Transceiver Hot Pluggable, Duplex LC, +3.3V, 1310nm DML/PIN, Single mode, 10km, 0~70 C

Specification. Small Form Factor Pluggable Transceiver (MSA) LC Receptacle SFP+ 12 Gigabit SDI TIM-A1CB1-F11

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

FTS-R27G-S31L-002DI. Multirate SFP 125Mbps-2.67Gbps, 1310nm, single-mode, 2km

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

OC-48/STM-16 Bi-directional SFP Transceiver (40km) RBT25SI2

Applications LX xDR 10Gb. Gb/s 10km XFP Optical Transceiver

DATA SHEET. Four (4) fibers Detachable HDMI Extender, HDFX-150-TR

Typical applications:

One channel video link With duplex data and contact closure

CFPQD010C10D CFP Dual Fibre 1310nm* / 10km / 100GBASE-LR4 & OTN OTU4

Product Specification 100m Multirate Parallel MMF 100/128G QSFP28 Optical Transceiver FTLC9551SEPM

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

Radiation-Hard Optical Link for SLHC

The Read-Out system of the ALICE pixel detector

25W 9xxnm Uncooled Multimode Laser Diode Module

FIBRE CHANNEL CONSORTIUM

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

RS-422 Data Transceiver Supports CWDM

QSFP+ 40GBASE-LR4 Fiber Transceiver

Transcription:

CMS Tracker Optical Control Link Specification Part 1: System Version 1.2, 7th March, 2003. CERN EP/CME Preliminary

1. INTRODUCTION...2 1.1. GENERAL SYSTEM DESCRIPTION...2 1.2. DOCUMENT STRUCTURE AND CONVENTION...3 1.3. RELATED WWW SITES...4 1.4. DOCUMENT HISTORY...4 1.5. CONTACTS...4 2. TECHNICAL REQUIREMENT, PART 1: SYSTEM...5 2.1. DESCRIPTION...5 2.2. BLOCK DIAGRAM...5 2.3. TARGET SPECIFICATIONS (@25 C UNLESS OTHERWISE NOTED)...6 2.4. OPERATING ENVIRONMENT...8 2.5. OTHER CHARACTERISTICS...9 2.6. TESTING...10 2.7. IMPLEMENTATION...11 3. GLOSSARY...12 3.1. SKEW...12 3.2. JITTER...12 4. REFERENCES...13 1

1. Introduction 1.1. General system description This specification defines the design requirements for the digital optical link to be used in the control system of the various sub-detectors of the CMS detector [1.1] at the CERN [1.2] Large Hadron Collider (LHC). The system architecture is based on the token ring concept, with mixed optical and copper sections [1.3]. The system was originally developed for the Tracker subdetector [1.4], where the total number of redundant control rings is 320, corresponding to 2560 optical link channels. In the other subsystems, namely ECAL, preshower and pixels, the combined total number of digital links required is expected to be a similar to that for the Tracker. The CMS optical control link is embedded into the control ring, as shown in Fig 1.1 taking the Tracker system as an example. The optical link is highlighted on the left of the figure, starting and ending at the backend transceiver module which is mounted on the Front End Controller board (FEC). Specifications for the FEC, and communication control unit (CCU) ASICs can be found in [1.5] and [1.6] respectively. Link Interface I2C channels to front-end modules Reset I2C CCUM 4 CCUM CCU CCU Digital Opto Hybrid Digital Opto Hybrid Patch panels 12 CCUM CCU CCUM CCU Front End ~ 100m 8 x 12 Back End processing Back-end Transceiver TTC FEC TIMING DAQ Control Fig. 1.1. Tracker control ring with optical link highlighted on the left. The communication architecture proposed to control the embedded electronics is based on two layers. A more detailed description can be found for instance in [1.3]. The first layer (called the Ring) connects the FEC to the CCU modules (CCUMs) as well as connecting between CCUMs on the same ring. The protocol on this first layer is message-based and is implemented in a way similar to LAN networks. Four lines are required to transmit data (40Mb/s) and system clock (40MHz) with redundancy. Optical links are used to transmit data between the back-end (FEC) and the front-end digital optohybrid (DOH). The data is then communicated between CCUMs via electrical interconnections. The second layer of communication, between the CCUMs and the front-end chips, is entirely electrical and is based on the I 2 C standard protocol. 2

1.2. Document structure and convention The optical link specification is broken down into eight independent parts, each describing and specifying a different level or function in the system: Part 1. System Part 2. Digital Opto-Hybrid 2.1 Laser Driver ASIC 2.2 Laser Transmitter 2.2.1 Terminated Pigtail 2.2.1.1 Buffered Fibre 2.3 PIN Photodiode 2.4 Digital Receiver ASIC 2.5 Digital Optohybrid Substrate Part 3. Terminated Fibre Ribbon 3.1 Ruggedized Ribbon Harness 3.1.1 Ruggedized Ribbon Part 4. Terminated Multi-Ribbon Cable 4.1 Dense Multi-Ribbon Cable Part 5. Back-End Opto-Transceiver Module Part 6. Distributed Patch Panel 6.1 MU-sMU Adaptor Part 7. In Line Patch Panel 7.1 MFS Adaptor Part 8. Backend Patch Panel 8.1 Connector Shell Each part has the following structure: 1. Introduction 1.1. System description 1.2. Document structure 1.3. Related WWW sites 1.4. Contact 1.5. Document history 2. Technical requirement 2.1. description 2.2. block diagram 2.3. specification 2.4. operating environment 2.5. other characteristics 2.6. testing 2.7. implementation 3. Glossary 4. References Due to the preliminary nature of this document, the specification section (section 2.3) of each system part is labelled "target specifications". CERN should be consulted before any hardware or software relying on these characteristics is being designed. Target specifications will eventually evolve into full specifications once the system definition is mature. Parameters still to be determined are labelled. 3

1.3. Related WWW sites CERN laboratory: http://www.cern.ch/public/ CMS project: http://cmsinfo.cern.ch/welcome.html CMS Tracker Technical Design Report: http://cmsdoc.cern.ch/ftp/tdr/tracker/tracker.html CMS Tracker Electronic System: http://cmstrackercontrol.web.cern.ch/cmstrackercontrol/docmain.htm CMS Tracker Optical Links: http://cms-tk-opto.web.cern.ch/ FED developments: http://www.te.rl.ac.uk/esdg/cms_fed_pmc/index.html APV and MUX developments: http://www.te.rl.ac.uk/med/ 1.4. Document history Rev. 1.0, 17/12/02 Rev. 1.1, 24/1/03 Rev. 1.2, 7/3/03 Draft (KG) Propagated changes from DOH and TRx specs. Power margins added.(kg) Modified output termination based on TRx specs.(kg) 1.5. Contacts All questions regarding this document should be addressed to: F. Vasey EP Division CERN CH-1211 Geneva 23 Fax: +41 22 767 2800 Phone +41 22 767 3885 E-mail francois.vasey@cern.ch K. Gill EP Division CERN CH-1211 Geneva 23 Fax: +41 22 767 2800 Phone +41 22 767 8583 E-mail karl.gill@cern.ch

2. Technical requirement, part 1: system 2.1. Description On the front-end DOH, labelled (1) in Fig. 2.1, the lasers are 1310nm InGaAsP/InP edge-emitters, pigtailed with single-mode 9/125/250/900µm fibre that is terminated with an MU connector. The receivers on the DOH are InGaAs/InP p-i-n photodiodes pigtailed in the same way as the lasers. Also mounted on the DOH are the LLD laser driver ASIC, and the RX40 receiver ASIC. After the distributed patch panel (5), which houses MU-sMU connections, the fibres attached to components on a given DOH (and its redundant back-up DOH) are then fanned into a 12-way ruggedized ribbon cable (2) using a compact fan-in element. In each ribbon there are 4 fibres transmitting light to the Tracker, 4 dark fibres, and 4 fibres transmitting light from the Tracker. The 12-fibre modularity matches that of the fibre-ribbon components used in the analogue readout link system at the relatively small expense of the additional dark fibre. The optical cables follow the same routing (in the Tracker) as for the readout links and will share the same in-line patch panels (6), using MFS connectors. Groups of eight ribbons are then fanned into 96-way dense multi-ribbon cables (3), which then pass to the counting room. At the back-end of the links in the counting room, 4+4 way transceiver modules (4), each having a 12-way MPO optical interface (7), will be mounted on the FEC. Altogether, 2560 optical readout channels (optical fibres) will be implemented for control of the CMS Tracker and a similar, perhaps greater number is expected to be required for the other CMS sub-systems, including ECAL, Preshower and Pixels. 2.2. Block diagram Reset I2C ~1m 1 Fan-in To/from CCUMs 1 ~5m ~60m 12 96 to/from FEC Single-way fibres Front-end Digital Optohybrid (DOH) 1 Ri bbon cable 2 Multi-ribbon Cable 3 Backend Transceiver Module (TRx) 4 Patch Panels 5 6 7 Fig. 2.1. Optical link block diagram 5

2.3. Target Specifications (@25 C unless otherwise noted) # operational specifications min typ max unit note 1.1 Total length 60 m 1.2 Bit Rate 2 80 Mb/s Balanced code 1.3 Bit Error Rate 10-12 10-9 1.4 Skew 2 ns Between any 2 fibres coming from the same hybrid, see glossary 3.1 1.5 Jitter 0.5 ns rms, see glossary 3.2 1.6 Operation rate 4000 hrs/year specs 1.7 to 1.10 reserved for future use # Front-end electrical specifications min typ max unit note 1.11 Differential input voltage ±300 mv Into 120Ω. Note that the LLD ASIC has an analogue transfer characteristic. 1.12 Input impedance 120 Ω 1.13 Differential output voltage ±250 ±400 mv LVDS. Should be terminated differentially with 100Ω. 1.14 Reset Output Active low Generated by RX40 upon reception of 10 consecutive 0 levels on Data channel at DOH. 1.15 Reset action at front-end DOH A reset is generated at LLD at power-up or when RX40 outputs a reset. Sets transmitter quiescent operating point to hard-wired startup settings (spec 1.19) 1.16 Power supply 2.25 2.7 V 1.17 Power dissipation 350 mw Per DOH worst-case (i.e. half control ring) 1.18 I2C address 11100 Fixed 1.19 Default LLD laser I2C bias setting X 1 X 2 X 3 0000 Where X 1 X 2 X 3 = 011 = 48 decimal (). Approximately 22mA. Value is selected during production. 1.20 Default LLD gain setting 12.5 ms Hard-wired in LLD 1.21 Electrical connector 26-way male NAIS See fig. 2.2 and Table 2.1 for connector pin assignment. Specs 1.22 to 1.30 Reserved for future use 6

# Back-end electrical specifications min typ max unit note 1.31 Differential input voltage ±400 ±600 mv LVPECL 1.32 Input impedance 100 Ω Both inputs terminated internally with 50Ω to V tt 1.33 Differential output voltage ±400 ±600 mv CML 1.34 Output impedance 100 Ω Both outputs terminated externally with 1kΩ to V cc 1.35 Power supply 3.1 3.3 3.5 V 1.36 Power dissipation 2 W Tx and Rx channels specs 1.37 to 1.40 reserved for future use # optical specifications min typ max unit note 1.41 Wavelength 1260 1310 1360 nm 1.42 Optical fibre between Single way tightfront-end digital buffered singlemode optohybrid(2) and fibre distributed patch-panel(6) 1.43 Optical fibre between Single way buffered distributed patch-panel(6) single-mode fibre and in-line patch-panel(7) fanned in to ruggedized 12-way single-mode ribbon. 1.44 Optical fibre between inline 96-way dense multi- patch-panel(7) and ribbon cable back-end patch-panel(8) Validated fibre. Validated fibre. See Table 2.3 for fibre channel assignment. Ribbon coloured according to Bellcore spec. Validated fibre. Table 2.3 for fibre channel assignment. Ribbon coloured according to Bellcore spec. 1.45 Distributed patch panel(6) MU-sMU Patch-panels distributed around the Tracker mechanical support structure 1.46 In-line patch-panel(7) MFS Patch-panels at the magnet cryostat level. 1.47 Back-end patch-panel(8) MPO Patch panels at TRx module(5) on FEC. Angle polished connectors specs 1.48-1.60 reserved for future use 7

2.4. Operating environment # environmental specifications min typ max unit note With reference to Fig. 2.1, the digital opto-hybrid (1) is situated inside the Tracker detector. Patch-panel (5) is at the edge of the Tracker detector mechanical support structure. Patch-panel (6) is at the magnet cryostat level. Patch-panel (7) is at the FEC crate front-panel, in the readout room. The transceiver module (4) is on the FEC board, in the readout room. 1.61 Magnetic field resistance for items (1), (2), (3), (5), 4 T parallel to particle beam axis (6) 1.62 Hadronic fluence for items (1), (2), (5) 1.63 Gamma radiation resistance for items (1), (2), (5) 1.64 Hadronic fluence for items (3), (6) 1.65 Gamma radiation resistance for items (3), (6) 1.66 Temperature for items (1) through (7) 1.67 Operating humidity for items (1), (2), (5), (6) 2e14 1/cm 2 Integrated over lifetime 1, 90% charged particles, 10% neutrons[2.1] 1.5e5 Gy(Si) Integrated over lifetime 1 [2.1] 1e12 n/cm 2 Integrated over lifetime[2.1] (1MeV) 100 Gy(Si) Integrated over lifetime[2.1]. -20 70 C Operation and Storage Dry lab environment Tracker environment. during testing and dry Nitrogen flow during operation 60 %RH 13 C dew point 1.68 Operating humidity for items (3), (4), (7) 1.69 Operation rate 4000 hours/year Specs 1.70 to 1.80 reserved for future use # safety specifications note 1.81 Optical Optical fibre system hazard IEC 825-1, 825-2, level 1 See ref [2.2] 1.82 Material composition Halogen-free material CERN IS-41, see reference [2.3] 1.83 Fire CERN standards for underground equipment CERN IS23 and IS41, see reference [2.3]. 1.84 Component flammability Flame retardant material IEC 332-1, IEC 1034, IEC 754-2, ABD 0032, CERN IS23, see reference [2.3]. specs 1.85 to 1.99 reserved for future use 1 Foreseen operating lifetime: nominal 10 years. 8

2.5. Other characteristics electrical interface at front end Front-end Connector type: 26 way NAIS male connector. Fig. 2.2: NAIS connector pin assignment Pin Designation Assignment IN0 IN1 SCLK SDA OUT0 OUT1 RST 3,5 7,9 11 13 15,17 19, 21 25 Clock IN from CCUM Data IN from CCUM SCLK = I2C clock from CCUM controlling the DOH SDA = I2C data from CCUM controlling the DOH Clock OUT to CCUM Data OUT to CCUM reset generated by RX40 output to CCUM Table 2.1: NAIS connector pin assignment 9

electrical interface at back-end TRx: Surface mount leadframe, to be soldered on FEC board. External termination resistors on output lines. Module and pin-out (see Table 2.2) Designatio n CK in A DA in A CK in B DA in B CK out A DA out A CK out B DA out B Pin number Fibre number in ribbon (preliminary) 1 2 3 4 12 11 10 9 Assignment CK (from FEC to CCUM ring A) DA (from FEC to CCUM ring A) CK (from FEC to CCUM ring B) DA (from FEC to CCUM ring B) CK (from CCUM ring A to FEC) DA (from CCUM ring A to FEC) CK (from CCUM ring B to FEC) DA (from CCUM ring B to FEC) Table 2.2: Backend module pin assignment Optical fibre-ribbon channel assignment (preliminary) Channe l 1 2 3 4 5 6 7 8 9 10 11 12 Assignment CK (from FEC to CCUM ring A) DA (from FEC to CCUM ring A) CK (from FEC to CCUM ring B) DA (from FEC to CCUM ring B) Dark Dark Dark Dark DA (from CCUM ring B to FEC) CK (from CCUM ring B to FEC) DA (from CCUM ring A to FEC) CK (from CCUM ring A to FEC) Table 2.3: Fibre ribbon channel assignment. 2.6. Testing Final in-system testing procedure. 10

2.7. Implementation The system implementation with components as specified provides the following optical power budget figures: (a) For the DOH to TRx links, from front-end to FEC: DOH Tx average launched power (dbm) -15-10 -5 0 0 0 DOH Tx signal amplitude (dbm) -5-10 -15-20 -25 Tx min OMA DOH to TRx links DOH Tx with 0.016uW/mA MU-sMU and MFS patch panels TRx saturation Tx max ave launch power TRx responsivity -5-10 -15-20 -25 TRx Rx sensitivity (dbm) -30-15 -10-5 0 TRx Rx saturation (dbm) -30 (b) For the TRx to DOH links, from FEC to the front-end: TRx Tx average launched power (dbm) -15-10 -5 0 0 0 TRx Tx signal amplitude (dbm) -5-10 -15-20 -25 TRx with MFS and MU-sMU patch-panels TRx min OMA TRx to DOH links Rx40 saturation TRx max ave launch power Rx40 sensitivity -5-10 -15-20 -25 DOH Rx sensitivity (dbm) -30-15 -10-5 0 DOH Rx saturation (dbm) -30 11

3. Glossary 3.1. Skew The skew is determined by measuring, for two channels, the average time t 50 required for a step response signal to reach 50% of its end value. The skew between channels i and j is defined as: 3.2. Jitter t skew =t 50, j t 50,i The rms jitter is defined as the rms deviation of the time t 50 required for a step response signal to reach 50% of its end value: t = 2 jitter (t 50 - t 50 ) 12

4. References [1.1] http://cmsinfo.cern.ch/cmsinfo/welcome.html [1.2] http://www.cern.ch/ [1.3] A. Marchioro, " Specifications for the control electronics of the CMS Inner Tracker", Draft V2, CERN [1.4] The tracker project, technical design report, CERN/LHCC 98-6 [1.5] A. Marchioro, "FEC specification", Draft, CERN [1.6] A. Marchioro, "CCU specification", Draft, CERN [2.1] M. Huhtinen, Studies of neutron moderator configurations around the CMS inner tracker and Ecal, CERN CMS TN/96-057, 1996. [2.2] K. Gill, Laser safety in the CMS Tracker optical links, http://edms.cern.ch/document/338505/1. [2.3] http://www.cern.ch/cern/divisions/tis/safdoc/instr_en.html 13