BRIGHT BRIGHTER BRIGHTEST ONE ILLUMINATOR DESIGN THREE LIGHT SOURCES featuring the EvenVue Reflector System
DVC (DIAGNOSTIC VIEWING CENTER) The features and benefits of the TECHLINE can be combined with MAXANT s family of Diagnostic Viewing Center (DVC) angled and corner mounting systems for maximum viewing flexibility. The DVC angulation system creates a two tier fixture with a vertical top tier and a bottom tier angled at 20 degrees. A TECHLINE illuminator housed in a DVC angulation system maintains all of the standard features associated with the TECHLINE, including: centralized cluster switching, minimal 1.8 separation between tiers, roller gravity grip, etc. The DVC angulation systems provide an optimal viewing environment for easy top to bottom image comparison. TECHLINE illuminators may also be positioned in a DVC Corner System. The DVC Corner System combined with the DVC Angulation System provides effective use of awkward corner space. DVC corner systems allow for a single viewing panel in the top tier of the corner system and a choice for the bottom section of either: a) a painted lower panel to cover the open area; or, b) a lower panel with a bright spot capability (as shown above, bright spot NOT included). All DVC products may be wall or counter top mounted. See TECHLINE Price Sheet for pricing information. DVC Angulation System CAT. NO. DESCRIPTION DIMENSIONS LEN. HGT. DVC11 1 OVER 1 ANGLED 14.25 41.75 DVC22 2 OVER 2 ANGLED 28.25 41.75 DVC33 3 OVER 3 ANGLED 42.25 41.75 DVC44 4 OVER 4 ANGLED 56.25 41.75 DVC55 5 OVER 5 ANGLED 70.25 41.75 DVC66 6 OVER 6 ANGLED 84.25 41.75 DVC Corner Systems DVC90 DVC91 CORNER KIT WITH BRITE SPOT CAPABILITY (BRITE SPOT NOT INCLUDED) CORNER KIT WITHOUT BRITE SPOT CAPABILITY All DVC angulation systems and corner systems must be specified at the time an order is placed. Not All DVC systems are retrofitable to existing fixtures. Other DVC angles may be available upon request.
TECHLINE by... by... One universal illuminator design available in multiple lighting configurations. FEATURE BENEFITS FEATURE BENEFITS One universal TECHLINE illuminator design available in a variety of lighting configurations 200 Series, Two Lamp 300 Series, Three Lamp 400 Series, Four Lamp DUAL BRIGHTNESS OPTION Available on TECHLINE 300 and 400 Series Thin, 3 3 /8 Depth, Steel Construction TECH-GRIP, Roller Gravity Film Holding System Cluster Switching STANDARD EvenVue Reflector System 1. One universal body design allows different light sources to be grouped in a single facility. 2. Engineered placement of lamps combined with EvenVue Reflector System provides optimum light distribution for all lamp configurations. 3. Provides the radiologist the opportunity to utilize the TECHLINE s engineered design with the preferred light source. The TECHLINE is available in the following lighting configurations: 1. Standard two lamp light source for reading films of normal density. 1. Three lamp light source provides additional brightness preferred by some radiologists. 1. Four Lamp light source creates the brightest techline illumination. 1. The DUAL BRIGHTNESS Option provides the flexibility of either HIGH or LOW illumination. All lamps are illuminated in the HIGH and LOW modes for uniform light distribution across the entire viewing panel. 2. One Brightness control switch governs each tier. 3. Film Activated Switching comes STANDARD with the DUAL BRIGHTNESS OPTION ONLY. 1. Thin profile is clean, simple and unobtrusive. 2. Recess mounted configurations mount flush in walls of standard thickness. 3. Durable steel construction is resistant to damage. 1. The TECH-GRIP s engineered design provides maintenance free reliability and performance. 2. The TECH-GRIP accommodates all film thicknesses and requires no field adjustments. 3. The TECH-GRIP is medium GRAY in color on a white illuminator background which conforms to most medical facility decors. 1. Single, centrally located control area (bottom center of all TECHLINE single and double tier configurations) provides maximum operating convenience. 2. Simple switch pattern which correlates to panel layout allows for instinctive control of all lighted surfaces. 1. MAXANT s EvenVue reflector system provides consistent, even light distribution throughout the viewing panel. 2. The EvenVue finish features a highly reflective finish for maximum consistency and long lasting durability. Continuous bottom film ledge Minimal 1.8 separation between tiers of double tiered fixtures Engineered design easily serviced U.L. Listed & C.S.A. Approved White Powder Coat Finish Film Activated Micro Switch (OPTIONAL) Multi-Panel Master Switch (OPTIONAL) Surface Mounted Electric Hardware Location (OPTIONAL) Re-Mount Retrofit Kit (Post Sale Option) THE BEST VALUE AND PERFORMANCE IN DIAGNOSTIC IMAGING 1. Allows for the reading of multiple small film formats on a viewing area. 1. Provides a viewing environment for top to bottom image comparison which minimizes eye shift and distractions. 2. Allows for minimal distance between films for optimum detection of patient irregularities. 1. All surface and recess mounted TECHLINE fixtures can be serviced without removing them from their installed position. 2. Viewing panels are easily removed for cleaning and lamp replacement without the requirement of tools. 3. Each TECHLINE viewing area has a separate front wireway panel which is easily removed for access to internal components. 1. All TECHLINE illuminator configurations are U.L. Listed and C.S.A. approved fixtures. 2. Meets all hospital, clinic and other construction safety requirements. 1. Standard Hospital White color provides cosmetic compatibility with all medical facility decors. 2. Durable coating provides a chip and wear resistant surface which is easily cleaned. 3. Cosmetically compatible with medium gray film grip and plexi holder. 1. Provides operating convenience by activating the lamps when the film is inserted in the film grip. 2. Eliminated excess light from surrounding panels when the film activated mode is used. 3. Reduces room heat build up from any panels not in use. 4. Three way rocker control switch allows flexibility for constant light or film activated light. 1. Single master control switch provides convenient ON/OFF fixture control. 2. Master Switches can be configured on a per fixture basis or on a per tier basis. 1. An OPTIONAL power location for surface mount hardwiring allows for direct wiring to wall power source of surface mounted fixtures. 1. All TECHLINE fixtures can be field retro-fitted to a surface or recess mounted fixture. 2. Eliminates costly Restocking Charges. 3. Provides maximum post-sale mounting flexibility. MAXANT Technologies, Inc. 7540 Caldwell Avenue Niles, IL 60714 Toll Free: (800) 307-4190 Phone: (847) 588-2280 Fax: (847) 588-1920
TECHLINE SPECIFICATIONS DESCRIPTION DIMENSIONS 200 SERIES-2 LAMP 300 SERIES-3 LAMP 400 SERIES-4 LAMP Surface Mounted Shipping Shipping Shipping Viewing Area* Length Height Catalog# Wt. Lbs. Catalog# Wt. Lbs. Catalog# Wt. Lbs. Single Panel 14 X 17 14 X 17 14 21 TS-201 24 TS-301 24 TS-401 24 2 Panel side by side 28 X 17 28 21 TS-202 44 TS-302 44 TS-402 44 3 Panel side by side 42 X 17 42 21 TS-203 64 TS-303 64 TS-403 64 4 Panel side by side 56 X 17 56 21 TS-204 64 TS-304 84 TS-404 84 5 Panel side by side 70 X 17 70 21 TS-205 107 TS-305 107 TS-405 107 6 Panel side by side 84 X 17 84 21 TS-206 125 TS-306 125 TS-406 125 1 Over 1 2 X 14 X 17 14 42 TS-211 37 TS-311 37 TS-411 37 2 Over 2 2 X 28 X 17 28 42 TS-222 82 TS-322 82 TS-422 82 3 Over 3 2 X 42 X 17 42 42 TS-233 125 TS-333 125 TS-433 125 4 Over 4 2 X 56 X 17 56 42 TS-244 158 TS-344 158 TS-444 158 5 Over 5 2 X 70 X 17 70 42 TS-255 307 (crated) TS-355 307 (crated) TS-455 307 (crated) 6 Over 6 2 X 84 X 17 84 42 TS-266 346 (crated) TS-366 346 (crated) TS-466 346 (crated) Recess Mounted Wall Cut-Out** Shipping Shipping Shipping Viewing Area* Length Height Catalog# Wt. Lbs. Catalog# Wt. Lbs. Catalog# Wt. Lbs. Single Panel 14 X 17 14 X 17 14.75 21.75 TR-201 26 TR-301 26 TR-401 26 2 Panel side by side 28 X 17 28.75 21.75 TR-202 45 TR-302 45 TR-402 45 3 Panel side by side 42 X 17 42.75 21.75 TR-203 64 TR-303 64 TR-403 64 4 Panel side by side 56 X 17 56.75 21.75 TR-204 87 TR-304 87 TR-404 87 5 Panel side by side 70 X 17 70.75 21.75 TR-205 107 TR-305 107 TR-405 107 6 Panel side by side 84 X 17 84.75 21.75 TR-206 128 TR-306 128 TR-406 128 1 Over 1 2 X 14 X 17 14.75 42.75 TR-211 39 TR-311 39 TR-411 39 2 Over 2 2 X 28 X 17 28.75 42.75 TR-222 86 TR-322 86 TR-422 86 3 Over 3 2 X 42 X 17 42.75 42.75 TR-233 126 TR-333 126 TR-433 126 4 Over 4 2 X 56 X 17 56.75 42.75 TR-244 165 TR-344 165 TR-444 165 5 Over 5 2 X 70 X 17 70.75 42.75 TR-255 328 (crated) TR-355 328 (crated) TR-455 328 (crated) 6 Over 6 2 X 84 X 17 84.75 42.75 TR-266 364 (crated) TR-366 364 (crated) TR-466 364 (crated) *Viewing height is actually 16.5 in order that extraneous light is eliminated when standard 14 x 17 film is inserted in the Roller Gravity Grip. **Overall Recessed Fixture dimensions, including recessed trim length and height, are each 3 greater than Surface Mounted Dimensions.
TECHLINE Bid Specification LIGHT SOURCE & LUMINANCE: Utilizing a universal body design, the TECHLINE series is available in any of the following light sources. Illumination Levels Amps Voltage Fluorescent (Expected Minimum cd/m 2 ) Per Panel Requirements Lamp Type TECHLINE 200 SERIES 2000 0.75 118V 60 Hz (2)-F15lT8/D per panel TECHLINE 300 Series 0.66 118V 60 Hz Standard High Intensity 3500* (3)-F15T8/D Optional Dual Intensity - Low Mode 2500 per panel Optional Dual Intensity - High Mode 3500* TECHLINE 400 Series 0.70 118V 60 Hz Standard High Intensity 4000* (4)-F15T8/D Optional Dual Intensity - Low Mode 2000 per panel Optional Dual Intensity - High Mode 3800* *The noted series exceeds the American College of Radiology recommended light level of 3000 cd/m 2 for Mammography viewing. Published readings are 3% less than actual test levels to allow for decreased light output as a result of normal usage. These light levels are taken from procedures specified by the German DIN 6856 standard. Currently this is the only published standard for evaluating the luminance levels of x-ray illuminators. These levels were measured under the following conditions: an ambient temperature of 21º Celsius (70º Fahrenheit), 118V line voltage, and new lamps. Light levels measured in the field may vary with the local environment, including: lamp age, line voltage, ambient temperature, and lamp temperature. These measurements are subject to change without notice. SPECIFICATION DATA: BODY CONSTRUCTION: 18 Gauge Welded Steel construction, 3 3 /8 deep body. BALLASTS: All ballasts are U.L. listed and C.S.A. approved rapid start, low leakage, thermally protected, Class P type. These ballasts have self starting reliability exceeding 10,000 cycles with an anticipated 50,000 hours of operating life. LINE CORD AND PLUG: Each surface mounted fixture comes standard with a grounded chassis, 7 line cord and NEMA 5-15P 2-pole, 3 wire ground. FILM GRIP: Roller gravity film holding system accommodates all film thickness variations. This grip will not scratch or tear film. Requires no field adjustments. Open sides facilitate viewing of oversize film. CONTINUOUS BOTTOM FILM LEDGE: Allows for the placement of small film formats on the top and bottom of viewing area. FINISH: Powder coated white finish is bonded to all steel surfaces to provide durable chip and wear resistant outer surface. Highly reflective inner finish provides optimal light distribution. DIFFUSING PANEL: 1/8 shatter resistant, U.L. Listed translucent thermoplastic. SWITCHES: The standard two position rocker switch provides manual ON/OFF lighting for each viewing area. ENGINEERED TWO TIERED FIXTURE DESIGN: Two tier configurations have a minimal separation of 1.8 between tiers allowing for convenient top to bottom image comparison. ENGINEERED DESIGN FOR EASY SERVICING: Viewing panel is easily removed without tools. Fixture is serviceable without having to remove fixture from wall. Individual wireway panels can be easily removed for direct access to problem panels. CLUSTER SWITCHING: Individual rocker control switches are a STANDARD feature and are centrally located at the bottom of the fixture, configured in the same layout as the viewing panels they control. OPTIONAL FEATURES: FILM ACTIVATED 3 POSITION ROCKER SWITCH: Provides for manual ON/OFF and film activated mode which activates the viewing area when a film is inserted into the film grip. MASTER SWITCH: Provided master ON/OFF control of the entire fixture. HOSPITAL GRADE PLUG: Heavy duty plug specified in certain municipalities. SURFACE MOUNT HARDWIRING: Single electrical power exit location on the rear of fixture allows for surface mounted fixtures to be directly wired to the wall. DIAGNOSTIC VIEWING CENTER ANGULATION AND CORNER MOUNTING: Angled mounting: top tier vertical and bottom tier angled at 20º maintaining centralized Cluster Switching located at bottom center of fixture which controls top and bottom tiers. (See DVC information on previous page.) Corner Mounting: creates an effective solution to awkward corner space. (See DVC information on previous page.) MAXANT Technologies, Inc. 7540 Caldwell Avenue Niles, IL 60714 Toll Free: (800) 307-4190 Phone: (847) 588-2280 Fax: (847) 588-1920
TECHLINE FEATURES COMPARISON CHART TECHLINE 200 SERIES TECHLINE 300 SERIES TECHLINE 400 SERIES TR-202 Cluster STD STD STD Switching Minimal 1.8 STD STD STD Separation Roller 1.8 Gravity STD STD STD Grip Continuous Bottom STD STD STD Film Ledge U. L. Listed STD STD STD CSA Approved STD STD STD Easy Servicing STD STD STD Design Film Activated OPT OPT OPT Switching Master OPT OPT OPT Switching Dual N/A OPT OPT Brightness Diagnostic Viewing OPT OPT OPT Center Hospital Grade OPT OPT OPT Plug Surface Mount OPT OPT OPT Hardware 220V. 50Hz OPT N/A OPT Ballast STD = Standard OPT = Optional N/A = Not Available TS-403 TS-304 FSLO14.01