PAL LSI - Robust and Reliable Sample Handling

Similar documents
PAL LSI - Robust and Reliable Sample Handling

Standard Test Method for Determination of Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas Chromatography

Accessory Catalogue. Where design meets performance. CTC Analytics AG Industriestrasse 20 CH-4222 Zwingen Switzerland

Accessory Catalogue 2006

GC Accessories. Accessories. Prep and Load Platform. PAL is a registered trademark of CTC Analytics AG Switzerland

Accessories. Prep and Load Platform. PAL is a registered trademark of CTC Analytics AG Switzerland

Achieving More Efficient Data Review with OpenLAB CDS

AIM INTRODUCTION SIMPLIFIED WORKFLOW

GCxGC Comprehensive Two-Dimensional Gas Chromatography

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

HPLC Tips and Tricks. Tiziana Ladisa Sales Support Specialist for Chromatography Italy Thermo Fisher Scientific, Rodano (MI)

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Liquid Chromatography- Mass Spectrometer Manual

CARESTREAM DIRECTVIEW Elite CR System

CARESTREAM DIRECTVIEW Elite CR System

AUTOMATIC COVERSLIPPER CVR909. Date of issue: 21/03/2019 Rev. 04

ChromQuest 5.0 Chromatography Data System

easyspiral Dilute The world's fi rst automatic diluter & plater A revolution in serial dilutions!

Accessories. LC Accessories. PAL and PAL-xt product line accessory catalogue 2010 / GC Accessories. Prep and Load Platform

PAL User Manual Installation and Operation. HTC PAL PAL HTC-xt. Printing History

PAL3 Autosampler Series Accessories & Consumables

1. Add Capture Antibody diluted in coating buffer. 4. Add standards, controls and samples to the plate in duplicate.

PAL3 Autosampler Series Accessories & Consumables

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

Vortex Mixers. Mini Vortex Mixers Heavy-Duty Vortex Mixers Microplate Vortex Mixers Multi-Tube Vortex Mixers. Asia Pacific

Staying Connected in GC

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

If you have questions or problems in providing anything described as Customer

easyspiral The world's fastest Spiral plater

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

Agilent High Capacity RV Pumps & Roots Pumping Systems

The world s fastest Spiral plater. easyspiral N

PAL3 Autosampler Series Accessories & Consumables

Model KT 53 Cooling incubators with thermoelectric cooling

Agilent GC Injector 80

Model KT 115 Cooling incubators with thermoelectric cooling

YXLON Cougar EVO PLUS

PROCESS HEAT. From LE to LHS: How to benefit from Leister s new generation of air heaters. We know how.

Sigma 4-16S Sigma 4-16KS Sigma 4-16KHS

World s smallest 5MP stand-alone vision system. Powerful Cognex vision tool library including new PatMax RedLine and JavaScript support

DM 50 / DM / 2- component dosing and mixing system. engineering

Introduction to the FTA2000

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Magnetic Stirrers Magnetic Stirr

STANDARD OPERATING PROCEDURE:

Operating pressure should be 6000 psi or better suitable for both analytical and semi-preparative applications

Industrial Diode Laser (IDL) System IDL Series

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Fernald Community Cohort Protocol Cyropreserved Biospecimens Sample Selection, Processing, Inventory and Storage

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Karl Heinz Feller. Arbeitsgruppe Instrumentelle Analytik FB Medizintechnik und Biotechnologie Ernst-Abbe-Fachhochschule Jena.

Benchtop performance in a compact footprint

April 2018 TALL FOOD & PHARMA PRODUCT INSPECTION

Accessory Catalogue 2006

SediVue Dx * Urine Sediment Analyzer User Guide

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

DM8000. # Designed and engineered in the U.K. Advanced Digital Audio Processor

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Our History. Experience since Today

IKA Analytical line Calorimeters C 2000

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

Thermo Scientific Polar Series Cooling/Heating Recirculating Chillers

Label Applicator HERMA 400

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

SMART CINEMAHORIZONTAL. User Guide VPSP Projector side. model. Notice SmartCrystal Cinema MUV V1R0

Combined A0 Strength. With Margin Adjustment you can create margins for easy storage of your drawings.

SmartCrystal Cinema Neo

SPECIFICATION NO NOTE

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V.

ih Series Drypumps (505) idealvac.com idealvac.com

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

Customized electronic part transport in the press shop siemens.com/metalforming

Just cool with green: GEA Küba market SP. The new standard for basic refrigeration applications

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

Tekna evo. innovation technology future 03

Supporting Information for Effectiveness of Global, Low-Degree Polynomial Transformations for GCxGC Data Alignment

CORONA & PLASMA FOR NARROW WEB

Technical Note. High-speed Agilent 1100 Series diode-array detector SL for optimization of resolution, sensitivity, spectral sensitivity and linearity

PERFORMANCE, PACKAGED FLEXIBLES VERTICAL PACKAGING SOLUTIONS THAT FIT

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

Reduction of operating costs

LEGEND MAX Human α-synuclein ELISA Kit with Pre-coated Plate Catalog No.: (Previously Covance Cat. No. SIG-38974)

PANEL RADIATORS - TECHNICAL MANUAL

Ritmo meets all your welding needs in your jobsite

PMCL300 Series TFT LCD Monitor 17-INCH, 19-INCH, OR 19-INCH WIDE, WITH MULTIMODE FUNCTIONALITY

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Viper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge

PRELIMINARY Sunny Boy 240-US

Dental Line. High frequency intraoral x-ray unit. radiology ahead

Model KT 170 Cooling incubators with thermoelectric cooling

Gurley Models LA18, LA20, LA25, High Resolution - Industrial Ruggedness

Sigma 3-16L Sigma 3-16KL

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Saddle-stitching System StitchLiner5500

CORONA & PLASMA FOR NARROW WEB

"CHOOSING A STATIC MIXER"

Transcription:

PAL LSI - Robust and Reliable Sample Handling

PAL LSI: Enhanced productivity due to innovative technology Large Sample Capacity: 162 x 2 ml-vials can be stored on one tray holder. The standard length PAL LSI can hold 648 x 2 ml - vials on four tray holders. With the optional Peltier stack samples can be stored at a controlled temperature. Process Safety: Proprietary drive technology enables the detection of missing vials and the correct position of the syringe needle in the injector port. Bending of syringe needles is excluded. Injector! correct position wrong position detected Missing vial detected Fast injections: Injections as fast as 100 ms reduce discrimination in GC down to C40 / C20 > 0.98. Complete injection cycle time 100 msec Step 1 Injector port penetration Step 2 Fast injection Step 3 Needle retraction 2

Reproducible results thanks to optimized injection handling Air Sample Air Solvent Sample Air Solvent Internal Standard Sample Only perfect injection handling gives reproducible results. From a simple injection (1) to sandwiching an internal standard (3): The PAL LSI is designed for the precise and accurate handling of liquid samples of up to 100 µl in volume. In combination with the PAL Sample Control software all parameters of aspirating and dispensing of liquid samples can be fully controlled. This is crucial for perfect injections. A range of syringes from 1.2 µl to 100 µl is available. In example (3) an aliquot of an internal standard is sandwiched between transport solvent and the sample. Air gaps in between the liquids preclude mixing of the different liquids. The accurate control of these steps is the basis of reproducible methods. 1 2 3 Vial Transport The PAL LSI is a robot that can reach any three dimensional position within its working area. It is able to transport vials, either to read barcodes or to transfer the vials into temperature controlled modules like the Agitator for heating samples or a Peltier Stack for cooling them down up to 4 C. 3

Configure your PAL LSI for the jobs you want done 4

Flexibility: A wide range of optional modules for the PAL LSI Additional Tray Plates increase the sample capacity. Supported vial formats are 1, 2, 10 and 20 ml, as well as 96 / 384 well micro titer plates and deep well plates. Up to 648 x 2 ml vials or 12 MTPs can be stored. Temperature controlled Peltier stacks for 2 or 6 sample trays or plates can be added to cool samples preventing degradation or to heat samples for derivatization reactions or kinetic studies. The Standard Wash Module is ideal for washing the syringe with up to four different solvents (4 x 10 ml solvent vial, 1 x 10 ml waste vial). An optional waste tube is available. The Large Wash Module is ideal for large volume injections (2 x 100 ml glass solvent container, waste port with tubing olive) The Fast Wash Module is preferred when low carry-over is required. It also cleans syringes incl. the outside of the needle (gauge 19 26) with 2 different solvents. The Solvent Module allows adding liquids (with three 100 ml solvent containers) The Vortex Mixer Module offers efficient mixing for dilution / extraction. Standard vial sizes: 2 ml / 10 ml / 20 ml 1 additional slot for custom specific vials Provides efficient mixing with up to 2000 rpm The Agitator Module provides 6 positions for 20 ml vials for incubation and agitation of samples. Temperature range 40 200 C Agitation speed 250 750 rpm Optional adapters for 2 ml or 10 ml vials The Barcode Reader Module reads horizontal 1D barcodes labels on 2 ml, 10 ml and 20 ml vials. The two scanners allow the identification of vials irrespective of the position of the barcode on the vials. Therefore it ensures highest process safety and traceability. With the Valve Drive Module different injection or switching valves can be configured. A wide variety of different valve types can be used. For more options/modules please contact your local Value Added Reseller or visit www.palsystem.com. 5

Ingenious Master Software PAL Sample Control Easy to use routine software PAL Sample Control software is the user-friendly tool for the daily routine jobs. Just a few clicks and sample lists are generated or imported. Now PAL Sample Control starts the operation and the data acquisition. Since PAL Sample Control interfaces seamlessly with major chromatographic or MS data systems only one sample list has to be handled. Different user levels ensure process safety. Productivity PAL Sample Control allows overlapping of multiple sample procedures. It optimizes automatically the timing of various steps in a sample preparation process and generates a schedule that minimizes the runtimes of sequences. This increases sample throughput greatly and boosts productivity. Powerful Method Editor While PAL Sample Control is straightforward to use in the daily operations it is also a powerful tool for the generation of tailored methods. A set of tested methods that comes with every system can be used as templates and optimized or tailored for specific workflows. Furthermore a large number of building blocks (tasks) for method development are part of the software. These building blocks make it easy to generate new methods, even for complex workflows. PAL Sample Control is the common platform for PAL RTC, PAL RSI, and PAL LSI, and is shipped with every PAL System. Supported CDS and MS-Data Systems Analyst ChemStation LC / GC / MSD Chromcard ChromPerfect ChromQuest Clarity Empower 2 EZChrom MassHunter GC / MS, LC / MS Master Lab QuanLab Xcalibur 6

Dimensions PAL LSI compact x-axis length PAL LSI standard x-axis length Working Area Width: 420 mm (16.8 inches) Depth: 255 mm (10.0 inches) Height: 420 mm (16.8 inches) Width: Depth: Height: 735 mm (28.9 inches) 255 mm (10.0 inches) 420 mm (16.8 inches) Footprint Instrument dimensions with standard legs Width: Depth: Height: 600 mm (24.0 inches) 795 mm (31.8 inches) 770 mm (30.8 inches) Width: Depth: Height: 915 mm (36.6 inches) 795 mm (31.8 inches) 770 mm (30.8 inches) Footprint from above Front View Working Area Working Area Sample Capacity 2 Tray Plates Up to 420 x 1 ml vials 324 x 2 ml vials 90 x 10 / 20 ml vials 6 x MT / DW plates 4 Tray Plates Up to 840 x 1 ml vials 648 x 2 ml vials 180 x 10 / 20 ml vials 12 x MT / DW plates Application Specifications * Type Specifications Comment Injection volume 0.1-100 µl Depending on syringe, available syringes are 1.2 / 5 / 10 / 25 and 100 µl, needle length 57 mm LC Liquid injection, repeatability (UV) LC Liquid injection, linearity (gravimetrical) Full loop < 0.1 % RSD Partial loop < 0.15 % RSD R > 0.9999 20 µl loop, 4 x overfill, 100 µl syringe 10 µl in 20 µl loop, 100 µl syringe 20, 40, 60, 80, 100 µl, n=3 each level GC liquid injection, repeatability < 0.60 % RSD Alkanes C14, C15, C16, 1 µl, split mode GC liquid injection, linearity (gravimetrical) R > 0.9999 20, 40, 60, 80, 100 µl, n=3 each level GC needle discrimination C40 / C20 > 0.98 Restek Florida Mix 1 µl, 100 ms fast split / splitless injection * Detailed conditions for the determination of specifications upon request 7

Distributed by: The PAL System is one of the most used and successful sample preparation and handling platforms. 40 000 systems worldwide are proof of the PAL Systems reliability and flexibility. PAL Systems are developed and manufactured under an ISO 9001 / 13485 quality management system. Every PAL System has passed a performance test before leaving the factory. The PAL LSI is designed for the accurate and precise handling of liquid samples. The PAL LSI can transport objects, like vials from and to any position within its working area. The PAL LSI is available with compact or standard x-axis length. The PAL LSI, like all members of the PAL family, can be upgraded if the need for more functionality or sample capacity arises. For more information on the PAL System visit: www.palsystem.com PAL is a registered trademark of CTC Analytics AG, Switzerland Part No. PAL Broch-LSI-Systems-2014 Rev 2 - November 2014