BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

Similar documents
Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Connection for filtered air

Advanced Test Equipment Rentals ATEC (2832)

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

PulseCounter Neutron & Gamma Spectrometry Software Manual

Standard Operating Procedure of nanoir2-s

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

ISO INTERNATIONAL STANDARD

Major Differences Between the DT9847 Series Modules

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Characterisation of the far field pattern for plastic optical fibres

Digital SWIR Scanning Laser Doppler Vibrometer

Characterization of Diamond Samples CHESS Run Summer 2013

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

EAN-Performance and Latency

SEM- EDS Instruction Manual

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Design Studies For The LCLS 120 Hz RF Gun Injector

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

Screen investigations for low energetic electron beams at PITZ

Product Guide. WaveAnalyzer High-Resolution Optical Spectral Analysis

Activity P27: Speed of Sound in Air (Sound Sensor)

Operating Instructions

OSA20 KEY FEATURES SPEC SHEET OPTICAL SPECTRUM ANALYZER

CBF500 High resolution Streak camera

DPD80 Infrared Datasheet

USB Mini Spectrum Analyzer User s Guide TSA5G35

New GRABLINK Frame Grabbers

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Topic: Instructional David G. Thomas December 23, 2015

Oscilloscopes, logic analyzers ScopeLogicDAQ

M2-Measurement Report

LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator)

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

LEP400 Etch Depth Monitor Real-time, in-situ plasma etch depth monitoring and end point control plus co-linear wafer vision system

Digital SWIR Scanning Laser Doppler Vibrometer

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

DT9837 Series. High Performance, USB Powered Modules for Sound & Vibration Analysis. Key Features:

GFT Channel Digital Delay Generator

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

2-/4-Channel Cam Viewer E- series for Automatic License Plate Recognition CV7-LP

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Industrial Diode Laser (IDL) System IDL Series

Scanning For Photonics Applications

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

On the Accuracy of Beam Position, Tilt, and Size Measured with a Shack-Hartman Wavefront Sensor

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

DPD80 Visible Datasheet

MAP Optical Power Meter Module (mopm-b1)

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Mini Micro Pulse Lidar System

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

In-process inspection: Inspector technology and concept

Contents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2.

MachineryMate 800 operating guide Handheld vibration meter

25W 9xxnm Uncooled Multimode Laser Diode Module

X-Cite XLED1. Advanced LED Illumination for Fluorescence Microscopy. Resetting the standard for LED illumination

Spectrometer. CCS Series Operation Manual

Getting Started with the LabVIEW Sound and Vibration Toolkit

Spectrometer. CCS Series Spectrometer Operation Manual

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

Operating Instructions

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

VL35 QUICKSTART GUIDE. 3.5" 4K HDMI Field Monitor w/ Canon LP-E6 Battery Plate

E X P E R I M E N T 1

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

Capstone screen shows live video with sync to force and velocity data. Try it! Download a FREE 60-day trial at pasco.com/capstone

USB Smart Power Sensor

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

843-R 843-R LASER POWER METER USER MANUAL. NEWPORT CORPORATION

Agilent DSO5014A Oscilloscope Tutorial

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

specification hyperion colorimeter

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

specification hyperion colorimeter

WaveDriver 20 Potentiostat/Galvanostat System

WA-7000 Multi-line Wavemeter OPERATING MANUAL

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

SigPlay User s Guide

The BAT WAVE ANALYZER project

Torsional vibration analysis in ArtemiS SUITE 1

Oculomatic Pro. Setup and User Guide. 4/19/ rev

HITACHI. Instruction Manual VL-21A

OPTICAL POWER METER WITH SMART DETECTOR HEAD

CAEN Tools for Discovery

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Requirements for the Beam Abort Magnet and Dump

8650A SERIES UNIVERSAL POWER METERS

4 MHz Lock-In Amplifier

Pre-processing of revolution speed data in ArtemiS SUITE 1

specification display applications cronus spectrometer & colorimeter

Transcription:

PRELIMINARY POWER DETECTORS ENERGY DETECTORS MONITORS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS CMOS Beam Profiling Camera AVAILABLE MODEL Beamage 3.0 (⅔ in CMOS Camera) ACCESSORIES Stand with Delrin Post (Model Number: 200428) MAIN FUNCTIONS Subtract Background CUB, CUB-UV & EAM-2 Beam Splitters and Attenuators KEY FEATURES Animate Normalize Filter Trigger Active Area (ROI) Stackable ND Filters (0.5, 1.0, 2.0, 3.0 & 4.0) 1 USB 3.0 for the Fastest Transfer Rates Up to 10X faster than regular USB 2.0 connections (also USB 2.0 compatible) 2 High Resolution 2.2 MPixels resolution gives accurate profile measurements on very small beams 3 Large Area Sensor The 11.3 x 6.0 mm sensor allows to measure very large beams 4 ISO Compliant D4σ Definition of Diameter, Centroid, Ellipticity and Orientation are ISO 11146:2004 and 11146:2005 compliant 5 Intuitive Software Interface Easy to navigate interface, with many display and control features: 2D, 3D and XY Displays Background Subtraction Function Unique "Animate" Function Gaussian Fit Semi-Log Graph 6 External Trigger To synchronize the camera with a pulsed laser 7 Low-Cost The most affordable, large size camera-based beam profiler on the market SEE ALSO Image Averaging Pixel Addressing ACCESSORIES FOR BEAM DIAGNOSTICS 186 LIST OF ALL ACCESSORIES 188 BEAM DIAGNOSTICS UV Converters & IR Adaptors Pelican Carrying Case 176

SPECIFICATIONS MODELS SENSOR TECHNOLOGY EFFECTIVE APERTURE MEASUREMENT CAPABILITY Wavelength Range Pixel Count H x V Pixel Dimension Minimum Measurable Beam Shutter Type Frame Rate (at 1 MPixels) RMS Noise ADC Level (User Setable) DAMAGE THRESHOLDS a Maximum Average Power Saturation Level (1064 nm) SOFTWARE Displays Display Features Beam Diameter Definitions Buffer Controls Printing and Reports PHYSICAL CHARACTERISTICS Sensor Size Sensor Area Dimensions (not including filter) Weight (head only) ORDERING INFORMATION Full Product Name Product Number (Stand not included) a. With ND4 filter. b. Available for order now, deliveries start in April 2013. Ask your Gentec-EO representative for pricing. CMOS 11.3 x 6.0 mm 350-1150 nm 2.2 MPixels 2048 x 1088 5.5 x 5.5 µm ~55 µm Global 10 fps 1000:1 (60 db) 12 bit (default) / 10 bit (option) 1 W CW: 10 W/cm 2 ; Pulsed: 300 µj/cm 2 2D, 3D and XY 2D: Print Screen, Reset View, Show/Hide Beam Diameter 3D: Print Screen, Reset View, Top View XY: Save Data, Zoom, Gaussian Fit, Semi-Log, Show/Hide Cursor, Show/Hide FWHM, Show/Hide 1/e 2 D4σ (ISO compliant) 1/e 2 along crosshairs (13.5%) FWHM along crosshairs (50%) 86% effective diameter (D86) Open File, Save Current Data, Save All Data, Previous/Next Image, Clear Buffer, Animate Full Report in Print Ready Format (2D, 3D, XY, Measures, Parameters) Print Screen in BMP format (2D and 3D) 11.3 x 6.0 mm 0.67 cm 2 61H x 81.1W x 19.7D mm 139 g 201939 b Specifications are subject to change without notice MONITORS ENERGY DETECTORS POWER DETECTORS PHOTO DETECTORS THZ DETECTORS OEM DETECTORS SPECIAL PRODUCTS HIGH POWER DETECTORS BEAM DIAGNOSTICS Catalogue 2013_V2.0 T 418.651.8003 1888 5GENTEC F 418.651.1174 www.gentec-eo.com info@gentec-eo.com 177

PRELIMINARY MONITORS ENERGY DETECTORS INTUITIVE SOFTWARE INTERFACE Capture Controls: Start/Stop, Subtract Noise File Controls: Save and Open Data Buffer Controls: View Data Offline Data Computation Software Info POWER DETECTORS BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS 178 Display Controls: Print, Refresh, Zoom, etc. Display Type: 2D, 3D or XY Graph Home and Setup Tabs: Set your capture parameters and get the resulting measures MAIN CONTROLS The top portion of the software is in a ribbon format and includes all the main controls. These are grouped by family, including capture controls, file controls, buffer controls and data computations such as a very useful spatial filter and a normalizing function. DISPLAYS The left-hand side of the software is the display panel. 3 displays are available: 3D, 2D and XY (cross-sectional graphs along the crosshairs). The various displays are chosen using the corresponding icons at the bottom of the panel. Convenient Print Screen controls are located the 2D and 3D displays and allow the user to save an image of the current view in BMP format. HOME and SETUP TABS The right-hand side of the software contains the Home and Setup tabs. The Home tab allows the user to select the type of measurements performed (like 4-sigma and FWHM). It also shows the resulting measures of the beam. The Setup tab contains all the measurement parameters, like Exposure Time, Image Orientation, Averaging, Active Area definition (ROI) and more.

2D, 3D AND XY DISPLAYS Crosshairs Diameter 3D DISPLAY The 3D display shows the actual shape of the beam. It is possible to easily zoom, pan and rotate the data. The very useful Reset button allows to put the data back in its original configuration. This display also features a Print Screen button to save the latest image in BMP format. Print Screen Reset View Top View 2D DISPLAY The 2D display features the crosshairs (set to the major and minor axis or along specified angles) and the measured diameter of the beam. This diameter varies with the chosen definition (4-sigma, FWHM, 1/e 2, etc.) and its display can be turned ON or OFF. The Print Screen button allows to save a picture of the current screen in BMP format. Print Screen XY DISPLAY Reset View Show/Hide Diameter The XY display plots cross-sectional graphs of the beam along the crosshairs. This display features many useful tools, like zoom, cursor, and FWHM and 1/e 2 level bars. It is also possible to display the graphs in semi-log format to enhance the details in the low intensity parts of the beam. Save Data Zoom Gaussian Fit Semi-Log Graph Show/Hide Cursor Show/Hide FWHM MONITORS ENERGY DETECTORS POWER DETECTORS PHOTO DETECTORS THZ DETECTORS OEM DETECTORS SPECIAL PRODUCTS HIGH POWER DETECTORS BEAM DIAGNOSTICS Catalogue 2013_V2.0 T 418.651.8003 1888 5GENTEC F 418.651.1174 www.gentec-eo.com info@gentec-eo.com 179

PRELIMINARY MONITORS ENERGY DETECTORS MAIN FUNCTIONS SUBTRACT BACKGROUND ANIMATE BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS POWER DETECTORS The background subtraction function is a necessary tool to have an accurate measurement and to abide by the ISO-11146-3:2004 standards. By taking 10 images and averaging them pixel by pixel to compute the average background map, contamination of all images can be avoided with the help of environment noise subtraction. FILTER Filter out the noise in your beam profile by using this spatial filter function. This tool is great for low quality lasers or low level signals. TRIGGER For the case of pulsed laser sources, the trigger function will be useful to synchronize the system s capture rate with the source s repetition rate, especially when this one is low (<16 Hz). To be achieved, a TTL (0-5 V) or other (1.1-24 V) trigger signal can be connected to the Beamage 3.0 camera via a BNC or SMA plug. ACTIVE AREA (ROI) Give life to your measures with the animate function. With as much as 32 frame images temporarily saved in the buffer, simply pressing the animation button will create a movie with any display (2D, 3D and XY). This allows to visualize the beam while working offline and have a recalculation process if the beam diameter definition or crosshair parameters are changed. NORMALIZE The normalize function spreads the intensity over the full range (0% to 100%). This is especially useful with low level signals or to enhance the variations in the beam. OFF ON OFF ON Increase the data transfer rate by reducing the area of the sensor that is scanned. This tool is perfect for small beams that don't need the full sensor area. IMAGE AVERAGING The image averaging function uses a temporal filter to provide the possibility to take 2, 5 or as much as 10 images of the beam to create a single timeaveraged image with them. This process will smooth the beam fluctuations that can occur over time when working with unstable laser sources. PIXEL ADDRESSING Increase the data tranfer rate by using larger pixels or by reducing the number of pixels. This is great for large beams that don't need the full resolution. Full Resolution Average Decimate 180 Every function may not be available yet

CHOOSING THE CORRECT BEAM DIAMETER DEFINITION Since Gaussians are infinitely large, borders have to be defined for the validity of calculation. To suit all types of requirements, the Beamage 3.0 software offers 4 different definitions for the beam diameter (d σ ) measurement. The first 3 definitions are appropriated for elliptical and circular profiles and the last one is for circular profiles only: 4 sigma (ISO): The beam diameter definition is set by default to 4 sigma because it conforms to the ISO 11146-1:2005 1 and ISO 11146-2:2005 2 standards. With this definition, the computation time is raised and thus the frame rate is reduced because almost the entire image (4 times the curve standard deviation) is used to compute the beam parameters. 1/e2 along crosshairs (13.5%): This definition is similar to 4 sigma but allows a faster frame rate. With this definition, the Gaussians are cut where the energy or intensity reaches 13,5 % of the peak value. Users can use this definition to increase the frame rate and still have a good approximation of the diameter of their elliptical beam. FWHM along crosshairs (50%): This definition is also faster than 4 sigma and works in a similar fashion as 1/e2 along crosshairs, but clips the beam at 50% of the peak value. 86% effective diameter (D86): This beam definition is designed for circular (or almost circular) profiles only. It computes the diameter of a circular beam containing 86% of the total energy or intensity. Since the software assumes the beam is cicular, it does not calculate the major and minor axes, nor the orientation and ellipticity, which makes D86 the fastest measurement mode. BEAM CENTROID, ELLIPTICITY AND ORIENTATION (ISO 11146:2005 1,2 COMPLIANCE) The beam centroid (center of energy) coordinates for both X and Y axes are given by these equations, which are weighted means for energy: The ellipticity, which can take a value between 0% and 100%, is defined as the ratio between the shorter (minor axis) and longer (major axis) widths. Evidently, a perfectly circular beam will have an ellipticity of 100%. The beam orientation, which can take a value from -45 to 45, is defined as the angle between the X axis of the sensor and the beam axis (either minor or major, whichever is closest). Catalogue 2013_V2.0 x = E(x,y,z)xdxdy E(x,y,z)dxdy GAUSSIAN FIT AND ROUGHNESS FIT y = E(x,y,z)ydxdy E(x,y,z)dxdy According to the ISO 13694:2000 3 standards, the roughness fit factor, which is an indicator of the maximum deviation between the theoretical Gaussian curve and the measured one, takes a value between 0% and 100% and is given by this equation: a E i - E i max Roughness Fit (%) = x 100% E max E is the measured curve and E a the theoretical one. The closer to 0% the better is the roughness fit. The Gaussian fit factor, on the other hand, indicates how the experimental curve is close to a theoretical Gaussian. It can take a value between 0% and 100% and is given by this equation: a E i - E i Gaussian Fit (%) = 1 - x 100% E is the measured curve and E a the theoretical one. The closer to 100% the better is the Gaussian fit. 1. ISO 11146-1:2005 : methods for measuring beam width, among others, only applicable for stigmatic and simple astigmatic beams. 2. ISO 11146-2:2005 : applicable to general astigmatic beams or unknown types of beams. Within this standard, the description of laser beams is done with the second order moments of the Wigner distribution. Relevant physical quantities such as beam widths can be calculated from them. 3. ISO 13694:2000 : test methods for laser beam power (energy) density distribution. E a i T 418.651.8003 1888 5GENTEC F 418.651.1174 www.gentec-eo.com info@gentec-eo.com MONITORS ENERGY DETECTORS POWER DETECTORS PHOTO DETECTORS THZ DETECTORS OEM DETECTORS SPECIAL PRODUCTS HIGH POWER DETECTORS BEAM DIAGNOSTICS 181